Features
Applications
■ Balanced Mini-TRIGARD™
■ Telecommunications
■ 5 mm diameter, 7.5 mm long
■ Industrial electronics
■ UL Recognized
■ Commercial electronics
■ RoHS compliant* versions available
■ Consumer electronics
2036 Series - Miniature 3-Pole Gas Discharge Tube
Characteristics
Additional Information
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 %
@ 100 V/s
Impulse Sparkover (1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±20 %
@ 100 V/s
Impulse Sparkover (1)
100 V/μs
1000 V/μs
(1)
Click these links for more information:
Model No.
2036-07
2036-09
2036-15
2036-20
2036-23
2036-25
75 V
90 V
150 V
200 V
230 V
250V
250 V
525 V
250 V
550 V
350 V
500 V
425 V
575 V
450 V
600 V
475 V
625 V
2036-30
2036-35
2036-40
2036-42
2036-47
2036-60
300 V
350 V
400 V
420 V
470 V
600 V
500 V
650 V
600 V
750 V
650 V
825 V
675 V
850 V
750 V
950 V
850 V
1100 V
PRODUCT TECHNICAL INVENTORY SAMPLES
SELECTOR LIBRARY
CONTACT
Model No.
Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay ..................1000 V/μs ............................................................................... < 75 ns
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... > 1010 Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 2 pF
DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09, ........................... < 150 ms
80 V for Model 2036-15)
Impulse Discharge Current .................20000 A, 8/20 μs (3) ................................................................. 1 operation minimum
10000 A, 8/20 μs .................................................................... > 10 operations
2000 A, 10/350 μs .................................................................. 1 operation
200 A, 10/1000 μs ................................................................. > 300 operations
200 A, 10/700 μs ................................................................... > 500 operations
Alternating Discharge Current ............20 Arms, 11 cycles (3) .............................................................. 1 operation
10 Arms, 1 s ........................................................................... > 10 operations
Storage Temperature .......................................................................................................................... -55 to +105 °C
Operating Temperature....................................................................................................................... -55 to +105 °C
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21
Moisture Sensitivity Level .................................................................................................................. 1
ESD Classification (HBM).................................................................................................................. 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C to
provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be soldered
either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering process that
does not exceed 210 °C.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of
this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
2036 Series - Miniature 3-Pole Gas Discharge Tube
Product Dimensions
2036-XX-A
2036-XX-B
5.0 ± 0.3
DIA.
(.197 ± .012)
26.9 ± 0.4
(1.060 ± .016)
7.5 ± 0.3
(.295 ± .012)
0.9 ± 0.3
(.035 ± .012)
0.8 ± 0.08
DIA.
(.031 ± .003)
4.0 ± 0.4
(.157 ± .016)
0.8 ± 0.08
DIA.
(.031 ± .003)
2036-XX-B2
FAIL-SHORT CONFIGURATION
2036-XX-B2F SHOWN
4.0 ± 0.4
(.157 ± .016)
0.8 ± 0.08
DIA.
(.031 ± .003)
5.3 ± 0.3
(.209 ± .012)
4.4 ± 0.3
(.173 ± .012)
4.4 ± 0.3
(.173 ± .012)
2036-XX-B3
6.2 ± 0.3
(.244 ± .012)
0.8 ± 0.08
DIA.
(.031 ± .003)
4.0 ± 0.4
(.157 ± .016)
0.8 ± 0.08
DIA.
(.031 ± .003)
3.8 ± 0.3
(.150 ± .012)
DIMENSIONS:
3.8 ± 0.3
(.150 ± .012)
MM
(INCHES)
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
2036 Series - Miniature 3-Pole Gas Discharge Tube
Switch-Grade Fail-Short Device Shorting Curve 2036-XX-XF
How to Order
2036 - xx - x (n) F LF
10.0
Model Number Designator
Current (A) (ELTGS)
5.0
Voltage (Divided by 10)
07 = 75 V
30 = 300 V
09 = 90 V
35 = 350 V
15 = 150 V
40 = 400 V
20 = 200 V
42 = 420 V
23 = 230 V
47 = 470 V
25 = 250 V
60 = 600 V
1.0
Leads
A = None
B = 0.8 mm
0.5
Lead Shape
(See Product Dimension Drawings)
Fail-Short Option
Blank = Standard Product
F = With Fail-Short Mechanism
0.1
RoHS Compliant Option
Blank = Standard Product
LF = RoHS Compliant Product
0.1
1
10
100
Seconds
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT failsafe device, it is imperative that all components
associated and connected to the GDT with failsafe be tested in their respective
completely integrated environment (finished product) to assure proper operation.
Packaging Specifications
Standard Packaging Quantity
Model
Bulk (Bag)
Tray
Box
2036-XX-A
250
1000
2036-XX-B
100
700
2036-XX-B2
100
1000
2036-XX-B3
100
1000
2036-XX-B2F
100
1000
Asia-Pacific: Tel: +886-2 2562-4117 • Email: asiacus@bourns.com
EMEA: Tel: +36 88 885 877 • Email: eurocus@bourns.com
The Americas: Tel: +1-951 781-5500 • Email: americus@bourns.com
www.bourns.com
REV. A 02/21
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Legal Disclaimer Notice
This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and
P[ZHɉSPH[LZJVSSLJ[P]LS`¸)V\YUZ¹
Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change
^P[OV\[UV[PJL
很抱歉,暂时无法提供与“2036-07-B2LF”相匹配的价格&库存,您可以联系我们找货
免费人工找货