2036-23-AF

2036-23-AF

  • 厂商:

    BOURNS(伯恩斯)

  • 封装:

    Cylinder No Lead,3 Terminal

  • 描述:

    GDT 230V 20% 10KA FAIL SHORT

  • 详情介绍
  • 数据手册
  • 价格&库存
2036-23-AF 数据手册
*R oH V SC AV ER OM AI SIO PL LA N IA BL S NT E Features Applications ■ Balanced Mini-TRIGARD™ ■ Telecommunications ■ 5 mm diameter, 7.5 mm long ■ Industrial electronics ■ UL Recognized ■ Commercial electronics ■ RoHS compliant* versions available ■ Consumer electronics ■ Automotive, aircraft, military electronics 2036 Series - Miniature 3-Pole Gas Discharge Tube Characteristics Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards. Characteristic DC Sparkover ±20 % @ 100 V/s Impulse Sparkover (1) 100 V/μs 1000 V/μs Characteristic DC Sparkover ±20 % @ 100 V/s Impulse Sparkover (1) 100 V/μs 1000 V/μs (1) Model No. 2036-07 2036-09 2036-15 2036-20 2036-23 2036-25 75 V 90 V 150 V 200 V 230 V 250V 250 V 525 V 250 V 550 V 350 V 500 V 425 V 575 V 450 V 600 V 475 V 625 V 2036-30 2036-35 2036-40 2036-42 2036-47 2036-60 300 V 350 V 400 V 420 V 470 V 600 V 500 V 650 V 600 V 750 V 650 V 825 V 675 V 850 V 750 V 950 V 850 V 1100 V Model No. Impulse Sparkover voltage is defined as typical values of distribution. Impulse Transverse Delay ..................1000 V/μs ............................................................................... < 75 ns Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... > 1010 Ω Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V Arc Voltage .........................................1 A .......................................................................................... ~ 10 V Glow-Arc Transition Current ............................................................................................................... < 0.5 A Capacitance........................................1 MHz ..................................................................................... < 2 pF DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09, ........................... < 150 ms 80 V for Model 2036-15) Impulse Discharge Current .................20000 A, 8/20 μs (3) ................................................................. 1 operation minimum 10000 A, 8/20 μs .................................................................... > 10 operations 2000 A, 10/350 μs .................................................................. 1 operation 200 A, 10/1000 μs ................................................................. > 300 operations 200 A, 10/700 μs ................................................................... > 500 operations Alternating Discharge Current ............20 Arms, 1 s (3) ........................................................................ 1 operation minimum 10 Arms, 1 s ........................................................................... > 10 operations Operating Temperature....................................................................................................................... -55 to +85 °C Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21 An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering process that does not exceed 210 °C. Notes: • UL recognized component, UL File E153537. • No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V). • The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground. • Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60). • Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory. • Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage. • At delivery AQL 0.65 Level II, DIN ISO 2859. (2) (3) Network applied. DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting. *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 2036 Series - Miniature 3-Pole Gas Discharge Tube Product Dimensions 2036-XX-A 2036-XX-B 5.0 ± 0.3 DIA. (.197 ± .012) 25.5 ± 0.6 (1.00 ± .024) 7.5 ± 0.3 (.295 ± .012) 0.9 ± 0.3 (.035 ± .012) 0.8 ± 0.04 DIA. (.031 ± .002) 4.0 ± 0.4 (.157 ± .016) 0.8 ± 0.04 DIA. (.031 ± .002) 2036-XX-B2 FAIL-SHORT CONFIGURATION 2036-XX-B2F SHOWN 4.0 ± 0.4 (.157 ± .016) 0.8 ± 0.04 DIA. (.031 ± .002) 5.3 ± 0.3 (.209 ± .012) 4.4 ± 0.3 (.173 ± .012) 4.4 ± 0.3 (.173 ± .012) 6.2 ± 0.3 (.244 ± .012) 2036-XX-B3 0.8 ± 0.04 DIA. (.031 ± .002) 4.0 ± 0.4 (.157 ± .016) 0.8 ± 0.04 DIA. (.031 ± .002) 3.8 ± 0.3 (.150 ± .012) DIMENSIONS: 3.8 ± 0.3 (.150 ± .012) MM (INCHES) Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 2036 Series - Miniature 3-Pole Gas Discharge Tube Switch-Grade Fail-Short Device Shorting Curve 2036-XX-XF How to Order 2036 - xx - x (n) F LF 10.0 Model Number Designator Current (A) (ELTGS) 5.0 Voltage (Divided by 10) 07 = 75 V 30 = 300 V 09 = 90 V 35 = 350 V 15 = 150 V 40 = 400 V 20 = 200 V 42 = 420 V 23 = 230 V 47 = 470 V 25 = 250 V 60 = 600 V 1.0 Leads A = None B = 0.8 mm 0.5 Lead Shape (See Product Dimension Drawings) Fail-Short Option Blank = Standard Product F = With Fail-Short Mechanism 0.1 RoHS Compliant Option Blank = Standard Product LF = RoHS Compliant Product 0.1 1 10 100 Seconds ELTGS = Each Line to Ground Simultaneously NOTE: When using a GDT failsafe device, it is imperative that all components associated and connected to the GDT with failsafe be tested in their respective completely integrated environment (finished product) to assure proper operation. Packaging Specifications Standard Packaging Quantity Model Bulk (Bag) 2036-XX-A 250 2036-XX-B 100 Tray Box 1000 700 2036-XX-B2 100 900 2036-XX-B3 100 900 2036-XX-B2F 100 900 REV. 11/15 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.
2036-23-AF
1. 物料型号:2036系列,包括不同的型号,如2036-07、2036-09、2036-15等,每个型号具有不同的击穿电压。

2. 器件简介:这些GDT用于多种应用,包括电信、工业电子、商业电子、消费电子、汽车、航空和军事电子。

3. 引脚分配:文档中没有明确说明引脚分配,但通常三极GDT有三个引脚。

4. 参数特性: - 直流击穿电压和脉冲击穿电压根据不同型号有不同的值。 - 绝缘电阻、辉光电压、弧电压和辉光-弧转换电流等参数也有具体数值。

5. 功能详解: - GDT用于保护电子设备免受电压浪涌的影响。 - 可选的Fail-Short装置在过热时提供高导电路径至地线。

6. 应用信息:适用于多种电子设备,以防止电压浪涌造成的损害。

7. 封装信息:提供了2036系列GDT的尺寸和形状,包括不同型号的尺寸细节。

8. 订购信息:提供了如何根据需要订购GDT的指南,包括型号、引脚形状、Fail-Short选项和RoHS合规选项。

9. 包装规格:列出了不同型号的标准包装数量。
2036-23-AF 价格&库存

很抱歉,暂时无法提供与“2036-23-AF”相匹配的价格&库存,您可以联系我们找货

免费人工找货