T
PL
IA
N
Applications
■ Size: 11.8 mm diameter,
■ Telecommunications equipment
17 mm length
100 kA surge rating
High power handling
Low leakage
RoHS compliant*
UL Recognized
■ Industrial equipment/electronics
*R
oH
S
CO
M
Features
■
■
■
■
■
2063 Series High-Current 2-Electrode Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12 and IEC 61643-311.
Model No.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2063-25
2063-30
2063-35
2063-42
230 V
250 V
300 V
350 V
420 V
< 600 V
< 700 V
< 600 V
< 700 V
< 700 V
< 800 V
< 800 V
< 900 V
< 900 V
< 1000 V
2063-47
2063-60
2063-70
2063-80
470 V
600 V
700 V
800 V
< 900 V
< 1100 V
< 1100 V
< 1300 V
< 1200 V
< 1400 V
< 1300 V
< 1500 V
(1)
Model No.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover (1)
100 V/µs
1000 V/µs
(1)
2063-23
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) (2) ....................................100 / 250 Vdc ........................................................ > 1 GΩ
Glow Voltage ...........................................................10 mA ..................................................................... ~ 70 V
Arc Voltage ..............................................................1 A .......................................................................... ~ 10 V
Glow-Arc Transition Current .................................................................................................................... < 1 A
Maximum Capacitance ............................................1 MHz ..................................................................... < 10 pF
Maximum Impulse Discharge Current .....................100,000 A, 8/20 µs ................................................ 1 operation
60,000 A, 8/20 µs ................................................... 5 operations
Nominal Alternating Discharge Current ...................60 A, 50 Hz, 1 second ............................................ 1 operation
300 A, 9 cycles ...................................................... 1 operation
Impulse Life ............................................................500 A, 10/1000 µs .................................................. > 400 operations
DC Holdover Voltage (3) ........................................................................................................................... < 150 ms
Operating Temperature............................................................................................................................ -30 to +85 ºC
Storage Temperature ............................................................................................................................... -40 to +115 °C
Climatic Category (IEC 60068-1)............................................................................................................. 40 / 90 / 21
Notes:
• UL Recognized component, UL File E313168.
• At delivery AQL 0.65, level II DIN ISO 2859
(2)
DC Sparkover Voltage
230–400 V
420–800 V
IR Measuring Voltage
100 V
250 V
(3)
Network Applied
DC Sparkover Voltage
230–250 V
300–800 V
DC Holdover Voltage
135 V
150 V
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
2063 Series High-Current 2-Electrode Gas Discharge Tube
Product Dimensions
How to Order
2063 - xx - A __ LF
Model Number Designator
Voltage (Divided by 10)
23 = 230 V
47 = 470 V
25 = 250 V
60 = 600 V
30 = 300 V
70 = 700 V
35 = 350 V
80 = 800 V
42 = 420 V
17.1 ± 0.3
(.673 ± .012)
Leads
A = No Leads
Packaging
(Blank) = Bulk Packaging - 35 pcs./tray (Standard)
RoHS Compliancy
LF = RoHS Compliant Product
Packaging Specifications
11.8 ± 0.2
(.465 ± .008)
DIMENSIONS:
Model 2063 ships standard bulk, 35 pcs. per tray; 105 pcs. per box.
MM
(INCHES)
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
REV. E 08/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.