2063 Series High-Current 2-Electrode Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12 and IEC 61643-311.
Model No.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover (1)
100 V/μs
1000 V/μs
DC Sparkover ±20 % @ 100 V/s
(1)
2063-25
2063-30
2063-35
2063-42
230 V
250 V
300 V
350 V
420 V
< 600 V
< 700 V
< 600 V
< 700 V
< 700 V
< 800 V
< 800 V
< 900 V
< 900 V
< 1000 V
2063-47
2063-60
2063-70
2063-80
470 V
600 V
700 V
800 V
< 900 V
< 1100 V
< 1100 V
< 1300 V
< 1200 V
< 1400 V
< 1300 V
< 1500 V
Model No.
Characteristic
Impulse Sparkover
100 V/μs
1000 V/μs
2063-23
(1)
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) (2) ....................................100 / 250 Vdc ........................................................ > 1 GΩ
Glow Voltage ...........................................................10 mA ..................................................................... ~ 70 V
Arc Voltage ..............................................................1 A .......................................................................... ~ 10 V
Glow-Arc Transition Current .................................................................................................................... < 1 A
Maximum Capacitance ............................................1 MHz ..................................................................... < 10 pF
Maximum Impulse Discharge Current .....................100,000 A, 8/20 μs ................................................ 1 operation
60,000 A, 8/20 μs ................................................... 5 operations
Nominal Alternating Discharge Current ...................60 A, 50 Hz, 1 second ............................................ 1 operation
300 A, 9 cycles ...................................................... 1 operation
Impulse Life ............................................................500 A, 10/1000 μs .................................................. > 400 operations
DC Holdover Voltage (3) ........................................................................................................................... < 150 ms
Operating Temperature............................................................................................................................ -30 to +85 ºC
Storage Temperature ............................................................................................................................... -40 to +115 °C
Climatic Category (IEC 60068-1)............................................................................................................. 40 / 90 / 21
Notes:
• UL Recognized component, UL File E313168.
• At delivery AQL 0.65, level II DIN ISO 2859
(2)
DC Sparkover Voltage
230–400 V
420–800 V
IR Measuring Voltage
100 V
250 V
(3)
Network Applied
DC Sparkover Voltage
230–250 V
300–800 V
DC Holdover Voltage
135 V
150 V
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of
this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Applications
■ Telecommunications equipment
■ Industrial equipment/electronics
2063 Series High-Current 2-Electrode Gas Discharge Tube
Product Dimensions
How to Order
2063 - xx - A __ LF
Model Number Designator
Voltage (Divided by 10)
23 = 230 V
47 = 470 V
25 = 250 V
60 = 600 V
30 = 300 V
70 = 700 V
35 = 350 V
80 = 800 V
42 = 420 V
17.1 ± 0.3
(.673 ± .012)
Leads
A = No Leads
Packaging
(Blank) = Bulk Packaging - 35 pcs./tray (Standard)
RoHS Compliancy
LF = RoHS Compliant Product
Packaging Specifications
11.8 ± 0.2
(.465 ± .008)
DIMENSIONS:
Model 2063 ships standard bulk, 35 pcs. per tray; 105 pcs. per box.
MM
(INCHES)
Asia-Pacific: Tel: +886-2 2562-4117 • Email: asiacus@bourns.com
EMEA: Tel: +36 88 885 877 • Email: eurocus@bourns.com
The Americas: Tel: +1-951 781-5500 • Email: americus@bourns.com
www.bourns.com
REV. E 09/19
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Legal Disclaimer Notice
This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and
P[ZHɉSPH[LZJVSSLJ[P]LS`¸)V\YUZ¹
Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change
^P[OV\[UV[PJL
很抱歉,暂时无法提供与“2063-60-ALF”相匹配的价格&库存,您可以联系我们找货
免费人工找货