Features
Additional Information
■ Axial leaded
Click these links for more information:
■ Fully compatible with current industry
standards
■ Weldable nickel terminals
S
014 350
4T
PRODUCT TECHNICAL INVENTORY SAMPLES
SELECTOR LIBRARY
■ Very low internal resistance
CONTACT
■ Agency recognition:
■ RoHS compliant*
MF-S Series - PTC Resettable Fuses
Electrical Characteristics
Ihold
Model
MF-S120
MF-S150
MF-S175
MF-S200
MF-S350
MF-S420
V max.
Volts
I max.
Amps
15
15
15
30
30
30
100
100
100
100
100
100
Itrip
Initial Resistance
1 Hour (R1)
Post-Trip
Resistance
Max. Time to Trip
Tripped
Power
Dissipation
Ohms
at 23 °C
Ohms
at 23 °C
Amperes Seconds
at 23 °C at 23 °C
Watts
at 23 °C
Amperes
at 23 °C
Hold
1.20
1.50
1.75
2.00
3.50
4.20
Trip
2.70
3.00
3.80
4.40
6.30
7.60
Min.
0.085
0.050
0.050
0.030
0.017
0.012
Max.
0.160
0.090
0.090
0.060
0.031
0.024
Max.
0.220
0.113
0.120
0.080
0.040
0.040
6
8
9
10
20
20
Typ.
1.20
1.30
1.50
1.90
2.50
2.90
5.0
5.0
4.0
4.0
3.0
6.0
Environmental Characteristics
Operating/Storage Temperature ........................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................ 125 °C
Passive Aging ....................................................... +85 °C, 1000 hours............................................... ±5 % typical resistance change
Humidity Aging...................................................... +85 °C, 85% R.H. 7 days...................................... ±5 % typical resistance change
Vibration ............................................................... MIL-STD-883C, Method 2007.1,........................... No change
Condition A
Moisture Sensitivity Level ..................................... 1
ESD Classification (HBM)
6
Test Procedures And Requirements For Model MF-S Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech. .................................................... Verify dimensions and materials .......................Per MF physical description
Resistance....................................................... In still air @ 23 °C.............................................Rmin ≤ R ≤ R1max
Time to Trip...................................................... At specified current, Vmax, 23 °C.....................T ≤ max. time to trip (seconds)
Hold Current .................................................... 30 min. at Ihold .................................................No trip
Trip Cycle Life.................................................. Vmax, Imax, 100 cycles....................................No arcing or burning
Trip Endurance ................................................ Vmax, 48 hours.................................................No arcing or burning
UL File Number .................................................... E174545
http://www.ul.com/ Follow link to Online Certificates Directory, then enter UL File No.
E174545, or click here
TÜV File Number.................................................. R 2057213
http://www.tuvdotcom.com/ Follow link to “other certificates”, enter File No. 2057213
or click here
Thermal Derating Chart - Ihold/ Itrip (Amps)
Model
Ambient Operating Temperature
-40 ºC
-20 ºC
0 ºC
MF-S120
1.90 / 4.28
1.70 / 3.83
1.50 / 3.38
1.20 / 2.70 1.00 / 2.25
0.90 / 2.03
0.80 / 1.80
0.70 / 1.58
0.50 / 1.13
MF-S150
2.20 / 4.40
2.00 / 4.00
1.80 / 3.60
1.50 / 3.00 1.30 / 2.60
1.10 / 2.20
1.00 / 2.00
0.90 / 1.80
0.70 / 1.40
MF-S175
2.50 / 5.59
2.30 / 5.14
2.00 / 4.47
1.70 / 3.80 1.50 / 3.35
1.30 / 2.91
1.20 / 2.68
1.10 / 2.46
0.90 / 2.01
MF-S200
3.20 / 7.04
2.80 / 6.16
2.50 / 5.50
2.00 / 4.40 1.70 / 3.74
1.60 / 3.52
1.40 / 3.08
1.20 / 2.64
0.90 / 1.98
MF-S350
5.40 / 9.72
4.80 / 8.64
4.30 / 7.74
3.50 / 6.30 3.00 / 5.40
2.80 / 5.04
2.50 / 4.50
2.20 / 3.96
1.70 / 3.06
MF-S420
6.40 / 11.5
5.70 / 10.3
5.10 / 9.23
4.20 / 7.60 3.60 / 6.51
3.30 / 5.97
3.00 / 5.43
2.60 / 4.70
2.10 / 3.80
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
23 ºC
40 ºC
50 ºC
60 ºC
70 ºC
85 ºC
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last
page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Applications
■ Rechargeable battery pack protection
■ Provides overcurrent protection with 125 °C trip temperature
MF-S Series - PTC Resettable Fuses
Product Dimensions
A
Model
B
Min.
19.9
(0.783)
21.3
(0.839)
20.9
(0.823)
21.3
(0.839)
28.4
(1.119)
30.6
(1.205)
MF-S120
MF-S150
MF-S175
MF-S200
MF-S350
MF-S420
Max.
22.1
(0.870)
23.4
(0.921)
23.1
(0.909)
23.4
(0.921)
31.8
(1.252)
32.4
(1.276)
Min.
4.9
(0.193)
10.2
(0.402)
4.9
(0.193)
10.2
(0.402)
13.0
(0.512)
12.9
(0.508)
C
Max.
5.2
(0.205)
11.0
(0.433)
5.2
(0.205)
11.0
(0.433)
13.5
(0.531)
13.6
(0.535)
Min.
0.6
(0.024)
0.5
(0.020)
0.6
(0.024)
0.5
(0.020)
0.5
(0.020)
0.5
(0.020)
D
Max.
1.0
(0.039)
1.1
(0.043)
1.0
(0.039)
1.1
(0.043)
1.1
(0.043)
1.1
(0.043)
Min.
5.5
(0.217)
4.1
(0.161)
4.1
(0.161)
5.0
(0.197)
6.3
(0.248)
5.0
(0.197)
F
Max.
7.5
(0.295)
5.5
(0.217)
5.5
(0.217)
7.6
(0.299)
8.9
(0.350)
7.5
(0.295)
Min.
3.8
(0.150)
4.8
(0.189)
3.8
(0.150)
4.8
(0.189)
6.0
(0.236)
6.0
(0.236)
Max.
4.1
(0.161)
5.4
(0.213)
4.1
(0.161)
5.4
(0.213)
6.6
(0.260)
6.6
(0.260)
Packaging: Bulk - 500 pcs. per bag. Tape and Reel - Consult factory.
A
DIMENSIONS:
Typical Part Marking
Represents total content. Layout may vary.
MANUFACTURER'S
TRADEMARK
F
B
MM
(INCHES)
S120
0180T
D
DATE CODE
(FIRST DIGIT =
LAST DIGIT OF YEAR;
NEXT THREE DIGITS =
DAY OF YEAR)
D
C
PART
IDENTIFICATION
LOT NO.
(T = TAIWAN
S = CHINA)
Terminal material: quarter-hard nickel
Typical Time to Trip at 23 ˚C
How to Order
MF
-S
MF 120
-S
MF 150
-S1
MF 75
-S2
00
MF
-S
MF 350
-S4
20
MF - S 120
Multifuse® Product
Designator
Series
S = Axial Leaded “Strap”
Component
10
Time to Trip (Seconds)
Hold Current, Ihold
120-420 (1.20 Amps - 4.20 Amps)
1
0.1
Asia-Pacific: Tel: +886-2 2562-4117
Email: asiacus@bourns.com
EMEA: Tel: +36 88 885 877
Email: eurocus@bourns.com
The Americas: Tel: +1-951 781-5500
Email: americus@bourns.com
www.bourns.com
0.01
0.001
1
10
Fault Current (Amps)
100
MF-S, REV. Q, 07/18
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Bourns
PPTC Resettable
Fuses
3312
- ®2 Multifuse
mm SMD® Trimming
Potentiometer
Application Notice
• Users are responsible for independent and adequate evaluation of Bourns® Multifuse® Polymer PTC devices in the user’s
application, including the PPTC device characteristics stated in the applicable data sheet.
•
Polymer PTC devices must not be allowed to operate beyond their stated maximum ratings. Operation in excess of such
maximum ratings could result in damage to the PTC device and possibly lead to electrical arcing and/or fire. Circuits with
inductance may generate a voltage above the rated voltage of the polymer PTC device and should be thoroughly evaluated
within the user’s application during the PTC selection and qualification process.
• Polymer PTC devices are intended to protect against adverse effects of temporary overcurrent or overtemperature
conditions up to rated limits and are not intended to serve as protective devices where overcurrent or overvoltage conditions
are expected to be repetitive or prolonged.
•
In normal operation, polymer PTC devices experience thermal expansion under fault conditions. Thus, a polymer PTC
device must be protected against mechanical stress, and must be given adequate clearance within the user’s application to
accommodate such thermal expansion. Rigid potting materials or fixed housings or coverings that do not provide adequate
clearance should be thoroughly examined and tested by the user, as they may result in the malfunction of polymer PTC
devices if the thermal expansion is inhibited.
• Exposure to lubricants, silicon-based oils, solvents, gels, electrolytes, acids, and other related or similar materials may
adversely affect the performance of polymer PTC devices.
•
Aggressive solvents may adversely affect the performance of polymer PTC devices. Conformal coating, encapsulating,
potting, molding, and sealing materials may contain aggressive solvents including but not limited to xylene and toluene,
which are known to cause adverse effects on the performance of polymer PTCs. Such aggressive solvents must be
thoroughly cured or baked to ensure their complete removal from polymer PTCs to minimize the possible adverse effect
on the device.
• Recommended storage conditions should be followed at all times. Such conditions can be found on the applicable data
sheet and on the Multifuse® Polymer PTC Moisture/Reflow Sensitivity Classification (MSL) note:
https://www.bourns.com/docs/RoHS-MSL/msl_mf.pdf
MFAN 12/18
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Legal Disclaimer Notice
This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and
P[ZHɉSPH[LZJVSSLJ[P]LS`¸)V\YUZ¹
Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change
^P[OV\[UV[PJL
很抱歉,暂时无法提供与“MF-S175”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+7.202241+0.92861