PVG5A103A01R00

PVG5A103A01R00

  • 厂商:

    BOURNS(伯恩斯)

  • 封装:

    SMD

  • 描述:

    可调电阻/电位器 10KΩ ±10% 250mW SMD ±100ppm/℃

  • 详情介绍
  • 数据手册
  • 价格&库存
PVG5A103A01R00 数据手册
R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. Trimmer Potentiometers SMD Sealed Type Multi-turn Type PVG5/PV01 Series 4.8 PVG5 Series ■ Features ADJ. Slot DIA 1.5 Width 0.6 Depth 0.5 5.0 3-0.9 #2 0.5 3.9 2.6 3-0.7 3-0.8 2.4 1.2 3.5 1. High resolution resulting from 11-turns design enables precise adjustment. 2. 5mm miniature size lead a high density PCB mounting. 3. Compatible with VPS reflow soldering method. 4. Compatible with ultrasonic cleaning. 5. Clutch mechanism prevents excessive wiper rotation. #3 0.2 #1 2.5 Schematic #2 ■ Applications PVG5A 1. Measuring instruments 2. sensors 3. CPUs 4. Industrial machines #1 #3 CLOCKWISE 4.8 2.4 4.9 3-0.8 2.6 3.7 1.2 0.5 ADJ.Slot DIA 1.5 Width 0.6 Depth 0.5 mm (Tolerancein: ±0.3 ) 3-0.7 3-0.9 #3 Schematic 2.3 #2 #2 PVG5H #1 #1 #3 CLOCKWISE mm (Tolerancein: ±0.3 ) Power Rating (W) Soldering Method Number of Turns (Effective Rotation Angle) Total Resistance Value TCR (ppm/°C) PVG5p100A01 0.25(70°C) Reflow 11 10ohm ±10% ±200 PVG5p200A01 0.25(70°C) Reflow 11 20ohm ±10% ±200 PVG5p500A01 0.25(70°C) Reflow 11 50ohm ±10% ±200 PVG5p101A01 0.25(70°C) Reflow 11 100ohm ±10% ±200 PVG5p201A01 0.25(70°C) Reflow 11 200ohm ±10% ±100 PVG5p501A01 0.25(70°C) Reflow 11 500ohm ±10% ±100 PVG5p102A01 0.25(70°C) Reflow 11 1k ohm ±10% ±100 PVG5p202A01 0.25(70°C) Reflow 11 2k ohm ±10% ±100 PVG5p502A01 0.25(70°C) Reflow 11 5k ohm ±10% ±100 PVG5p103A01 0.25(70°C) Reflow 11 10k ohm ±10% ±100 PVG5p203A01 0.25(70°C) Reflow 11 20k ohm ±10% ±100 PVG5p503A01 0.25(70°C) Reflow 11 50k ohm ±10% ±100 PVG5p104A01 0.25(70°C) Reflow 11 100k ohm ±10% ±100 PVG5p204A01 0.25(70°C) Reflow 11 200k ohm ±10% ±100 PVG5p504A01 0.25(70°C) Reflow 11 500k ohm ±10% ±100 PVG5p105A01 0.25(70°C) Reflow 11 1M ohm ±10% ±100 PVG5p205A01 0.25(70°C) Reflow 11 2M ohm ±10% ±100 Part Number The blank column is filled with the code of adjustment direction A (top) or H (side). 33 6 R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. ■ Construction Adjustment Screw Gear Case #2 Terminal Wiper Resistive Element #1, #3 Terminal Ceramic Substrate ■ Standard Land Pattern PVG5A PVG5H 1.6 2.25 1.2 1.3 1.3 mm (Tolerance in: ±0.1 ) ■ Characteristics 6 Temperature Cycle Humidity Vibration Shock ∆TR ±2% ∆V.S.S. ±1% ∆TR ±2% IR 10Mohm min. ∆TR ±1% ∆V.S.S. ±1% ∆TR ±1% ∆V.S.S. ±1% ∆TR ±3% or 3ohm max., Temperature Load Life Low Tamperature Exposure High Tamperature Exposure Rotational Life (100 cycles) whichever is greater ∆V.S.S. ±1% ∆TR ±1% ∆V.S.S. ±1% ∆TR ±2% ∆V.S.S. ±1% ∆TR ±3% or 3ohm max., whichever is greater ∆TR : Total Resistance Change ∆V.S.S. : Voltage Setting Stability IR : Insulation Resistance 34 2.8 1.6 2.25 1.6 1.6 1.3 2.8 1.3 1.3 1.0 1.3 mm (Tolerancein: ±0.1 ) R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. PV01 Series 6.4 1.8±0.2 DIA 3−1.0 4.0 1. High resolution, resulting from 12-turns design enables precise adjustment. 2. Compatible with VPS reflow soldering method. 3. Small size. (6.35x6.35x4.3mm) 4. Compatible with ultrasonic cleaning. 5. Clutch mechanism prevents excessive wiper rotation. 0.6±0.2 6.7 0.6 1.0 #2 3−0.4±0.1 Dia. #1 #3 2.5 2.5 #2 ■ Applications 1. Measuring instruments 3. CPUs 5. Printers 1.2 1.1 ■ Features PV01P #1 2. Facsimile machines 4. PPCs 6. Sensors #3 mm (Tolerancein: ±0.3 ) Clockwise 6.4 1.1 1.2 4.0 #2 3−0.4±0.1 Dia. #1 #3 2.5 2.5 1.8±0.2 Dia. 3−1.0 #2 PV01W 0.6 6.7 1.0 0.6±0.2 #1 #3 mm (Tolerancein: ±0.3 ) Clockwise 6.4 4.0 #2 2.5 6 1.1 6.7 1.1 2.5 1.8±0.2 Dia. #3 0.6±0.2 3−0.4±0.1 Dia. #1 0.6 1.0 3−1.0 #2 PV01X #1 #3 Clockwise mm (Tolerancein: ±0.3 ) Power Rating (W) Soldering Method Number of Turns (Effective Rotation Angle) Total Resistance Value TCR (ppm/°C) PV01p100A01 0.25(85°C) Reflow 12 10ohm ±10% ±100 PV01p200A01 0.25(85°C) Reflow 12 20ohm ±10% ±100 PV01p500A01 0.25(85°C) Reflow 12 50ohm ±10% ±100 PV01p101A01 0.25(85°C) Reflow 12 100ohm ±10% ±100 PV01p201A01 0.25(85°C) Reflow 12 200ohm ±10% ±100 PV01p501A01 0.25(85°C) Reflow 12 500ohm ±10% ±100 PV01p102A01 0.25(85°C) Reflow 12 1k ohm ±10% ±100 PV01p202A01 0.25(85°C) Reflow 12 2k ohm ±10% ±100 PV01p502A01 0.25(85°C) Reflow 12 5k ohm ±10% ±100 PV01p103A01 0.25(85°C) Reflow 12 10k ohm ±10% ±100 PV01p203A01 0.25(85°C) Reflow 12 20k ohm ±10% ±100 PV01p253A01 0.25(85°C) Reflow 12 25k ohm ±10% ±100 PV01p503A01 0.25(85°C) Reflow 12 50k ohm ±10% ±100 PV01p104A01 0.25(85°C) Reflow 12 100k ohm ±10% ±100 PV01p204A01 0.25(85°C) Reflow 12 200k ohm ±10% ±100 PV01p254A01 0.25(85°C) Reflow 12 250k ohm ±10% ±100 Part Number Continued on the following page. 35 R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. Continued from the preceding page. Power Rating (W) Soldering Method Number of Turns (Effective Rotation Angle) Total Resistance Value TCR (ppm/°C) PV01p504A01 0.25(85°C) Reflow 12 500k ohm ±10% ±100 PV01p105A01 0.25(85°C) Reflow 12 1M ohm ±10% ±100 Part Number The blank column is filled with the code of adjustment direction P (side), W (top) or X (rear). Magazine packaging is standard for PV01 series. ■ Construction Gear Case Terminal Adjustment Screw Wiper and Ratchet Arm Cermet Resistive Element Alumina Substrate ■ Standard Land Dimension PV01P PV01W/PV01X 1.6 1.6 3.4 1.6 3.8 1.8 4.85 1.8 6 3.8 4.85 1.8 1.8 1.6 mm (Tolerancein: ±0.1 ) ■ Characteristics Temperature Cycle Humidity Vibration (20G) Shock (100G) Temperature Load Life Low Tamperature Exposure High Tamperature Exposure Rotational Life (200 cycles) ∆TR ±1% ∆V.S.S. ±1% ∆TR ±2% IR 100Mohm min. ∆TR ±1% ∆V.S.S. ±1% ∆TR ±1% ∆V.S.S. ±1% ∆TR ±2% ∆V.S.S. ±1% ∆TR ±1% ∆V.S.S. ±1% ∆TR ±2% ∆V.S.S. ±1% ∆TR ±2% ∆TR : Total Resistance Change ∆V.S.S. : Voltage Setting Stability IR : Insulation Resistance 36 1.6 3.4 1.6 mm (Tolerancein: ±0.1 ) catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please R50E12.pdf 02.9.5 you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. PVG5/PV01 Series Notice ■ Notice (Operating and Storage Conditions) 1. Store that the temperature is -10 to +40deg. C and the relative humidity is 30-85%RH. 2. Do not store in or near corrosive gases. 3. Use within six months after delivery. 4. Open the package just before using. 5. Do not store under direct sunlight. 6. The trimmer potentiometer should not be used under the following environmental conditions: If you use the trimmer potentiometer in an environment other these listed below, please consult with Murata factory representative prior to using. (1) Corrosive gaseous atmosphere. (Ex. Chlorine gas, Hydrogen sulfide gas, Ammonia gas, Sulfuric acid gas, Nitric oxie gas, etc.) (2) In liquid. (Ex. Oil, Medical liquid, Organic solvent, etc.) (3) Dusty/dirty atmosphere. (4) Direct sunlight. (5) Static voltage nor electric/magnetic fields. (6) Direct sea breeze. (7) Other variations of the above. ■ Notice (Rating) 1. When using with partial load (rheostat), minimize the power depend on the resistance value. 2. The maximum input voltage to a trimmer potentiometer should not exceed (P•R)^1/2 or the maximum operating voltage, whichever is smaller. 3. The maximum input current to a trimmer potentiometer should not exceed (P/R)^1/2 or the allowable wiper current, whichever is smaller. ■ Notice (Soldering and Mounting) 1. Soldering (1) Standard soldering condition (a) Reflow and flow soldering : Refer to the standard temperature profile. (b) Soldering iron : >Temperature of tip 260 deg.C max. >Soldering time 3sec. max. >Diameter 2mm dia. max. >Wattage of iron 30W max. Before using other soldering conditions than those listed above, please consult with Murata factory representative prior to using. If the soldering conditions are not suitable, e. g., excessive time and/or excessive temperature, the trimmer capacitor may deviate from the specified characteristics. (2) Can not be soldered using the flow soldering method. If you use the flow soldering method, the trimmer potentiometer may not function. (3) The soldering iron should not come in contact with the case of the trimmer potentiometer. If such contact does occur, the trimmer potentiometer may be damaged. (4) Insufficient amounts of solder can lead to insufficient soldering strength on PCB. Excessive amounts of solder may cause the bridging between the terminals. 2. Mounting (1) Use our standard land dimension. Excessive land area causes displacement due to effect of the surface tension of the solder. Insufficient land area leads to insufficient soldering strength of the chip. (2) Do not apply excessive force (preferable 9.8N (Ref.; 1kgf) max.), when the trimmer potentiometer is mounted to the PCB. (3) Do not warp and/or bend PC board to prevent trimmer potentiometer from breakage. (4) In chip placers, the recommended size of the cylindrical pick-up nozzle should be outer dimension 4.0mm dia. and inner dimension 2.0mm dia.. 3. Cleaning (1) Isopropyl-alcohol and Ethyl-alcohol are applicable solvent for cleaning. If you use any other types of solvents, please consult with Murata factory representative prior to using. (2) The total cleaning time by cold dipping, vaper and ultrasonic washing (conditions as below) method shall be less than 3 minutes. (3) For ultra-sonic cleaning, the available condition is as follows. >Power : 600W (67liter) max. >Frequency : 28kHz >Temperature : Ambient temperature Due to the ultra-sonic cleaning equipment peculiar self resonance point and the cleaning compatibility usually depends on the jig construction and/or the cleaning condition such as the depth of immersion, please check the 6 Continued on the following page. 37 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please R50E12.pdf 02.9.5 you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. PVG5/PV01 Series Notice Continued from the preceding page. cleaning equipment to determine the suitable conditions. If the trimmer potentiometer is cleaned by other conditions, the trimmer potentiometer may be damaged. ■ Reflow Soldering Standard Profile For reflow soldering Pre-heating(in the air) Soldering Gradual Cooling (in the air) Temperature (°C) 230 200 100 0 60~120 sec. 30 sec. max. Time (Melting zone) ■ Notice (Handling) 6 1. Use suitable screwdrivers that fit comfortably in driver slot.We recommend the below screwdrivers. * Recommended screwdriver for manual adjustment VESSEL MFG. : NO. 9000-1.3x30 (Murata P/N : KMDR130) VESSEL MFG. : NO. 9000-1.8x30 (Murata P/N : KMDR110) We can supply above screwdrivers. If you place order, please nominate Murata P/N. ■ Notice (Other) 1. Please make sure that your product has been evaluated and confirmed against your specifications when our product is mounted to your product. 2. Murata connot guarantee trimmer potentiometer integrity when used under conditions other than those specified in this document. 38 2. Don't apply more than 9.8N (Ref.; 1kgf) of twist and stress after mounted onto PCB to prevent contact intermittence. If excessive force is applied, the trimmer potentiometer may not function. 3. When adjusting with a screwdriver, do not apply excessive force (preferable 4.9N (Ref; 500gf) max.) 4. When using a lock paint to fix slot position, please use adhesive resin without chlorine or sulfur (Three-bond "1401series"). R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. SMD Sealed Type/Lead Type Specifications and Test Methods Specifications and TestSealed Methods The following describes trimmer potentiometer testing conducted by Murata Manufacturing Co., Ltd. in accordance with MIL-R-22097 (Military specification for variable resistors, non-wirewound) and MIL-STD-202 (Test methods for electronic and electrical component parts). No. Item Test Methods Measure total resistance between the resistance element and terminals (#1 and #3) with the contact arm positioned against a stop. The positioning of the contact arm and terminal shall be the same for subsequent total resistance measurements on the same device. Use the test voltage specified in Table-1 for total resistance measurements. This voltage shall be used for all subsequent total resistance measurements. 1 Total Resistance Total resistance, Nominal (ohm) 10VRV100 100FRV1k 1kFRV10k 10kFRV100k 100kFR Maximum Test Voltage (V) 1.0 3.0 10.0 30.0 100.0 Table-1 Total resistance test voltage 2 Residual Resistance Position the contact arm at the extreme counterclockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. Then, position the contact arm at the extreme clockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. During this test, take suitable precautions to ensure that the rated current of the resistance element is not exceeded. Contact resistance variation shall be measured with the measuring circuit shown in Figure-1, or its equivalent. The adjustment rotor (screw) shall be rotated in both directions through 90% of the actual effective-electrical rotational angle(number of turns) for a total of 6 cycles. Only the last 3 cycles shall count in determining whether or not a contact resistance variation is observed at least twice in the same location, exclusive of the roll-on or roll-off points where the contact arm moves from the termination, on or off, the resistance element. The rate of rotation of the adjustment rotor (screw) shall be such that the adjustment rotor (screw) completes 1 cycle for 5 seconds minimum to 2 minutes maximum. The test current used shall follow the value given in Table-2 unless otherwise limited by power rating. 3 Contact Resistance Variation Standard total resistance R (ohm) RV100 100FRF500 500VRF1k 1kVRF2k 2kVRF50k 50kVRF200k 200kVRF1M 1MVRF2M 2MVR Test current 20mA 10mA 4mA 2mA 1mA 200µA 100µA 50µA 30µA #1 Rx Oscilloscope #3 #2 Constant Current Source not to Proofreaded Exceed Rating of Unit Being Resistance AC Amplifier Rx : Trimmer Potentiometer Oscilloscope bandwidth :100Hz to 50kHz Figure-1 CRV measuring circuit Table-2 Test current for CRV The trimmer potentiometer shall be subjected to the following each temperature (see Table-3) for 30-45 minutes. Temperature coefficient of resistance shall be applied to the following formula. R2 – R1 TCR= R1 (T2 – T1) Z 106 (ppm/°C) 4 Temperature Coefficient of Resistance T1 T2 R1 R2 : Reference temperature in degrees celsius : Test temperature in degrees celsius : Resistance at reference temperature ohm : Resistance at test temperature in ohm Sequence 1* 2 Temperature(°C) +25 -15 3 Min. operating temperature 4* 5 +25 +65 6 Max. operating temperature Note) * : Reference temperature Table-3 Test temperatures The wiper shall be set at approximately 40% of the actual effective-electrical rotational angle (number of turns). An adequate DC test potential shall be applied between the terminal #1 and the terminal #3. The voltage between the terminal #1 and the terminal #3, and the voltage between the terminal #1 and the terminal #2, shall be measured and applied to the following formula. E 9 5 Voltage Setting Stability Voltage setting stability= ( e'E – Ee ) Z100 (%) e : Before test (The voltage between the terminal #1 and the terminal #2) e': After test (The voltage between the terminal #1 and the terminal #2) E : The voltage between the terminal #1 and the terminal #3 #1 #3 #2 e Figure-2 Continued on the following page. 72 1 R50E12.pdf 02.9.5 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. SMD Sealed Type/Lead Sealed Type Specifications and Test Methods Specifications and Test Methods Continued from the preceding page. No. Item Test Methods The trimmer potentiometer shall be subjected to Table-4 temperature for 5 cycles. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 1~2 hours. 6 Temperature Cycle 1 Sequence PV-- series Temp. -55±3 PV22 series (°C) PVF2 series -25±3 Time (min.) 30 2 3 4 +125±3 +25±2 +150±3 +25±2 +60±3 30 5 max. 5 max. Table-4 One cycle of temperature cycle. 1) PVC6, PV12, PV32, PV34 PVM4A---B01series The trimmer potentiometer shall be placed in a chamber at a temperature of 40±2°C and a humidity of 90~95% without loading for 250±8 hours. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/6 hours. 2) PVF2series The trimmer potentiometer shall be placed in a chamber at 60±2°C and 90~95% without loading for 1000±12 hours. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/6 hours 2) PVG3, PVG5, PV01, PV22, PV23, PV36, PV37series The trimmer potentiometer shall be subjected Figure-3 the programmed humidity environment for 10 cycle. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/2 hours. MIL-STD-202 METHOD 106 80-98%RH 70 65 60 55 Humidity TEMPERTURE (DEGREES CELSIUS) 7 40 90-98%RH 90-98%RH 24 HOURS RATE OF CHANGE OF TEMPERATURE IS UNSPECIFIED. HOWEVER, SPECIMENS SHALL NOT BE SUBJECTED TO RADIANT HEAT FROM CHAMBER-CONDITIONING PROCESSES 50 45 80-98%RH 90-98%RH INITIAL CONDITIONING IN A DRY OVEN HUMIDITY UNCONTROLLED 35 30 +10°C -2°C CIRCULATION OF CONDITIONING AIR SHALL BE AT A MINIMUM CUBIC RATE PER MINUTE EQUIVALENT TO 5 TIMES THE VOLUME OF THE CHAMBER 25 20 15 INITIAL MEASUREMENTS AS SPECIFIED IN 3.2 10 5 0 -5 -10 END OF FINAL CYCLE MEASUREMENTS AS SPECIFIED IN 3.6 VOLTAGE APPLIED AS SPECIFIED IN 3.5 UNLESS OTHERWISE SPECIFIED TEMPERATURE TOLERANCE IS, ±2°C AT ALL POINTS WITHIN THE CHAMBER EXCEPT THE IMMEDIATE VICINITY OF THE SPECIMENS AND THE CHAMBER SURFACES PRIOR TO FIRST CYCLE STEP 1 UNLESS OTHERWISE SPECIFIED STEPS 7a AND 7b PERFORMED DURING ANY 5 OF THE FIRST 9 CYCLES. HUMIDITY UNCONTROLLED DURING STEPS 7a AND 7b ONLY STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7b STEP 7a STEP 7 ONE CYCLE 24 HOURS. REPEAT AS SPECIFIED IN 3.3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Figure-3 Vibration 1) PV-- series The trimmer potentiometer shall be vibrated throughout the frequency range at the 20G level. A complete frequency range, 10Hz to 2000Hz and back, shall be made within 15 minutes for a total of 4 sweeps in each of the three axis direction for a total of 12 sweeps. 2) PVF2 series The trimmer potentiometer shall be subjected to vibration at 0.3 inch amplitude. The frequency shall be varied uniformly between the approximate limits of 10 Hz and 55Hz. This motion shall be applied for preiod of 2 hours in each of 3 mutually perpendicular direction (total of 6 hours). Shock 1) PV-- series The trimmer potentiometer shall be shocked at the 100G (50G for PV22 and PV23series) level and shall be subjected to 4 shocks in each of the three axis direction for a total of 12 shocks. 2) PVM4A---B01series The trimmer potentiometer shall be shocked at the 100G level and shall be subjected to 3 shocks in each of the six axis direction for a total of 18 shocks. 10 Temperature Road Life Full rated continuous working voltage not exceeding the maximum rated voltage shall be applied intermittently between the terminal #1 and the terminal #3 of the trimmer potentiometer, 1.5 hours on and 0.5 hours off, for a total of 1000±12 hours, at a temperature of 70±2°C (85±2°C for PV01 and PV37series, 50±2°C for PVF2series). The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 1 to 2 hours. 11 High Temperature Exposure (Except for PVF2) The trimmer potentiometer shall be placed in a camber at a temperature of 125±3°C (150±3°C for PV12series) 250±8 hours without loading. The trimmer potentiometer shall be removed from the camber, and maintained at a temperature of 25±5°C for 1 to 2 hours. 12 Low Temperature Exposure (Except for PVF2 and PVM4A---B01) The trimmer potentiometer shall be placed in a camber at a temperature of -55±3°C for 1 hours without loading. Full rated continuous working voltage not exceeding the maximum rated voltage shall be applied for 45 minutes. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for approximately 24 hours. 8 9 Continued on the following page. 1 73 9 catalog to prevent smoking and/or burning, Pleaseread readrating ratingand and!CAUTION !CAUTION(for (forstorage storageand andoperating, operating,rating, rating,soldering solderingand andmounting, mounting,handling) handling)ininthis thisPDF catalog to prevent smoking and/or burning, etc. etc. !Note •Please R50E12.pdf 02.9.5 you are requested approvespecifications. our product specification or to transact theour approval for product specificaion before ordering. •This Thiscatalog cataloghas hasonly onlytypical typicalspecifications. specificationsTherefore, because there is no space fortodetailed Therefore, please approve productsheet specification or transact the approval sheet for product specification before ordering. SMD Sealed Type/Lead Type Specifications and Test Methods Specifications and TestSealed Methods Continued from the preceding page. No. 13 Item Low Temperature Operation (Only for PVF2 and PVM4A---B01) Test Methods The trimmer potentiometer shall be placed in a camber at a temperature of -25±3°C (-55±3°C for PVM4A--B01series) 48±4 hours without loading. The trimmer potentiometer shall be removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/6 hours 1)PV-- series Full rated continuous working voltage not exceeding the maximum rated voltage shall be applied with the circuit shown in the figure. The adjustment rotor (screw) shall be continuously cycled through not less than 90% of effective-electrical rotational angle (number of turns), at the rate of 1 cycle for 5 seconds minimum to 2.5 a minutes maximum for total of 200 cycles. End Terminal Resistor 1 End Terminal 14 End Terminal Resistor 2 End Terminal Rotational Life DC supply Figure-4 2) PVG3, PVG5series The adjustment rotor (screw) shall be continuously cycled though not less than 90% of effective- electrical rotational angle (number of turns), at the rate of 1 cycle for 5 seconds minimum to 2.5 minutes maximum for a total of 50 (100 for PVG5) cycles, without loading. 3) PVF2, PVM4A---B01series The wiper shall be rotated over 90% of the effective rotational angle without loading at a speed of 10 cycles per minute, for 100 cycles continuously. 9 74
PVG5A103A01R00
物料型号:文档中提到了两个系列的可变电阻器,分别是PVG5系列和PV01系列。

器件简介: - PVG5系列:具有11转设计,提供高分辨率,5mm小型尺寸,适用于高密度PCB安装,兼容VPS回流焊接方法和超声波清洗,具有防止刮刷器过度旋转的离合机制。 - PV01系列:具有12转设计,提供高分辨率,尺寸更小(6.35x6.35x4.3mm),兼容VPS回流焊接和超声波清洗,也有防止刮刷器过度旋转的离合机制。

引脚分配:文档中提供了PVG5系列和PV01系列的引脚分配图,包括调整槽直径、宽度和深度等信息。

参数特性:列出了不同型号的可变电阻器的功率等级、焊接方法、有效旋转角度、总电阻值和温度系数(TCR)。

功能详解:文档中提到了这些可变电阻器的应用领域,包括测量仪器、传感器、CPU、工业机器等。

应用信息:详细列出了PVG5系列和PV01系列的应用场景。

封装信息:提供了PVG5系列和PV01系列的标准焊盘图案尺寸和公差。
PVG5A103A01R00 价格&库存

很抱歉,暂时无法提供与“PVG5A103A01R00”相匹配的价格&库存,您可以联系我们找货

免费人工找货