0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TBU-CA025-050-WH

TBU-CA025-050-WH

  • 厂商:

    BOURNS(伯恩斯)

  • 封装:

    SMD,6.5X4MM

  • 描述:

    Transient Blocking Unit (TBU) - Bidirectional - 6.5 x 4 x 0.85 mm - Maximum impulse voltage 250V - M...

  • 数据手册
  • 价格&库存
TBU-CA025-050-WH 数据手册
PL IA NT Features ■ Superior circuit protection ■ Overcurrent and overvoltage protection ■ Blocks surges up to rated limits A5 E07 050 5 Applications ■ Voice / VDSL cards ■ Protection modules and dongles ■ Process control equipment ■ Test and measurement equipment ■ General electronics *R oH S CO M ■ High speed performance ■ Small SMT package ■ Agency recognition: TBU-CA Series - TBU® High Speed Protectors General Information Line In/ The TBU-CA Series of Bourns® TBU® Line Out products are low capacitance single bidirectional high speed protection components, constructed using MOSFET semiconductor technology, and designed to protect against faults caused by short circuits, AC power cross, induction and lightning surges. Line Out/ Line In Agency Approval Description UL File Number: E315805 TBU® Device The TBU® high speed protector placed in the system circuit will monitor the current with the MOSFET detection circuit triggering to provide an effective barrier behind which sensitive electronics will not be exposed to large voltages or currents during surge events. The TBU® device is provided in a surface mount DFN package and meets industry standard requirements such as RoHS and Pb Free solder reflow profiles. Absolute Maximum Ratings (@ TA = 25 °C Unless Otherwise Noted) Symbol Parameter Part Number TBU-CA025-xxx-WH TBU-CA040-xxx-WH TBU-CA050-xxx-WH TBU-CA065-xxx-WH TBU-CA085-xxx-WH TBU-CA025-xxx-WH TBU-CA040-xxx-WH TBU-CA050-xxx-WH TBU-CA065-xxx-WH TBU-CA085-xxx-WH Value 250 400 500 650 850 100 200 250 300 425 -40 to +125 -65 to +150 +125 ±2 Unit Vimp Peak impulse voltage withstand with duration less than 10 ms V Vrms Continuous A.C. RMS voltage V Top Tstg Tjmax ESD Operating temperature range Storage temperature range Maximum Junction Temperature HBM ESD protection per IEC 61000-4-2 °C °C °C kV Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com *RoHS Directive 2002/95/EC Jan 27, 2003 including Annex. Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. TBU-CA Series - TBU® High Speed Protectors Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted) Symbol Parameter Part Number TBU-CAxxx-050-WH TBU-CAxxx-100-WH TBU-CAxxx-200-WH TBU-CAxxx-300-WH TBU-CAxxx-500-WH TBU-CA025-050-WH TBU-CA025-100-WH TBU-CA025-200-WH TBU-CA025-300-WH TBU-CA025-500-WH TBU-CA040-050-WH TBU-CA040-100-WH TBU-CA040-200-WH TBU-CA040-300-WH TBU-CA040-500-WH TBU-CA050-050-WH TBU-CA050-100-WH TBU-CA050-200-WH TBU-CA050-300-WH TBU-CA050-500-WH TBU-CA065-050-WH TBU-CA065-100-WH TBU-CA065-200-WH TBU-CA065-300-WH TBU-CA065-500-WH TBU-CA085-050-WH TBU-CA085-100-WH TBU-CA085-200-WH TBU-CA085-300-WH TBU-CA085-500-WH Min. 50 100 200 300 500 Typ. 75 150 300 450 750 13.3 7.1 4.2 3.2 2.6 14.3 8.1 5.2 4.3 3.6 15.7 9.5 6.6 5.6 5.0 17.7 11.5 8.6 7.6 7.0 21.4 15.2 12.3 11.3 10.7 Max. 100 200 400 600 1000 15.3 8.2 4.8 3.8 3.0 16.5 9.4 6.0 5.0 4.2 18.0 10.9 7.5 6.5 5.7 20.3 13.2 9.8 8.8 8.0 24.5 17.4 14.0 13.0 12.2 1 0.25 12 0.50 16 98 40 1.00 20 µs mA V °C/W °C/W Unit Itrigger Current required for the device to go from operating state to protected state mA Vimp = 250 V Vimp = 250 V Vimp = 250 V Vimp = 250 V Vimp = 250 V Vimp = 400 V Vimp = 400 V Vimp = 400 V Vimp = 400 V Vimp = 400 V Vimp = 500 V Vimp = 500 V Vimp = 500 V Vimp = 500 V Vimp = 500 V Vimp = 650 V Vimp = 650 V Vimp = 650 V Vimp = 650 V Vimp = 650 V Vimp = 850 V Vimp = 850 V Vimp = 850 V Vimp = 850 V Vimp = 850 V tblock IQ Vreset Rth(j-l) Rth(j-l) Itrigger (min.) = 50 mA Itrigger (min.) = 100 mA Itrigger (min.) = 200 mA Itrigger (min.) = 300 mA Itrigger (min.) = 500 mA Itrigger (min.) = 50 mA Itrigger (min.) = 100 mA Itrigger (min.) = 200 mA Itrigger (min.) = 300 mA Itrigger (min.) = 500 mA Itrigger (min.) = 50 mA Itrigger (min.) = 100 mA Itrigger (min.) = 200 mA Itrigger (min.) = 300 mA Itrigger (min.) = 500 mA Itrigger (min.) = 50 mA Itrigger (min.) = 100 mA Itrigger (min.) = 200 mA Itrigger (min.) = 300 mA Itrigger (min.) = 500 mA Itrigger (min.) = 50 mA Itrigger (min.) = 100 mA Itrigger (min.) = 200 mA Itrigger (min.) = 300 mA Itrigger (min.) = 500 mA Rdevice Series resistance of the TBU device Ω Time for the device to go from normal operating state to protected state Current through the triggered TBU® device with 50 Vdc circuit voltage Voltage below which the triggered TBU® device will transition to normal operating state Junction to package pads - FR4 using recommended pad layout Junction to package pads - FR4 using heat sink on board (6 cm2) (1 in2) Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. TBU-CA Series - TBU® High Speed Protectors Reference Application The TBU devices are general use protectors used in a wide variety of applications. The maximum voltage rating of the TBU® device should never be exceeded. Where necessary, an OVP should be employed to limit the maximum voltage. A costeffective protection solution combines Bourns® TBU® protection devices with a pair of Bourns® MOVs. For bandwidth sensitive applications, a Bourns® GDT may be substituted for the MOV. ® Basic TBU Operation The TBU® device, constructed using MOSFET semiconductor technology, placed in the system circuit will monitor the current with the MOSFET detection circuit triggering to provide an effective barrier behind which sensitive electronics are not exposed to large voltages or currents during surge events. The TBU® device operates in approximately 1 µs - once line current exceeds the TBU® device’s trigger current Itrigger. When operated, the TBU® device restricts line current to less than 1 mA typically. When operated, the TBU® device will block all voltages including the surge up to rated limits. After the surge, the TBU® device resets when the voltage across the TBU® device falls to the Vreset level. The TBU® device will automatically reset on lines which have no DC bias or have DC bias below Vreset (such as unpowered signal lines). If the line has a normal DC bias above Vreset, the voltage across the TBU® device may not fall below Vreset after the surge. In such cases, special care needs to be taken to ensure that the TBU® device will reset, with software monitoring as one method used to accomplish this. Bourns application engineers can provide further assistance. Line Out / Line In TBU TM Device Line In / Line Out OVP Line Equip. TBU TM Device Line Out / Line In Line In / Line Out OVP Line Performance Graphs Typical V-I Characteristics (TBU-CA050-300-WH) ITRIP CURRENT (100 mA/div) VRESET Typical Trip Current vs. Temperature 1.8 Normalized Trip Current (A) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 -75 -50 -25 0 25 50 75 100 125 150 VOLTAGE (5 V/div) Junction Temperature (°C) Power Derating Curve 3.0 Typical Resistance vs. Temperature No Additional PCB Cu 0.5 sq. in. Additional PCB Cu 2.2 2.5 Normalized Resistance (Ω) 140 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 -75 -50 -25 Total Max. Power (W) 2.0 1.5 1.0 0.5 0.0 20 40 60 80 100 120 Junction Temperature (°C) 0 25 50 75 100 125 150 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. Junction Temperature (°C) TBU-CA Series - TBU® High Speed Protectors Product Dimensions 0.70 (.028) 1.85 (.073) 6.50 ± 0.10 (.256 ± .004) 0.85 ± 0.05 (.033 ± .002) 0.30 (.012) 0.80 (.031) 0.70 (.028) 1.85 (.073) 4.00 ± 0.10 (.157 ± .004) 3.40 (.134) PIN 1 & BACKSIDE CHAMFER 0.30 (.012) C 0.25 PIN 1 (.010) 0.00 - 0.05 (.000 - .002) Pad Designation Pad # 1 2 3 Pin Out Line In/Out NU Line Out/In DIMENSIONS: MM (INCHES) Recommended Pad Layout TBU® protectors have matte-tin termination finish. The suggested layout should use Non-Solder Mask Define (NSMD). The recommended stencil thickness is 0.10-0.12 mm (.004.005 in.) with a stencil opening size 0.025 mm (.0010 in.) less than the device pad size. As when heat sinking any power device, it is recommended that wherever possible, extra PCB copper area is allowed. For minimum parasitic capacitance, do not allow any signal, ground or power signals beneath any of the pads of the device. Thermal Resistance vs Additional PCB Cu Area 120 Thermal Resistance (°C/W) 100 80 60 40 20 0 3 2 1 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Added Cu Area (Sq. In.) Dark grey areas show added PCB copper area for better thermal resistance. Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. TBU-CA Series - TBU® High Speed Protectors Reflow Profile Profile Feature Average Ramp-Up Rate (Tsmax to Tp) Preheat - Temperature Min. (Tsmin) - Temperature Max. (Tsmax) - Time (tsmin to tsmax) Time maintained above: - Temperature (TL) - Time (tL) Peak/Classification Temperature (Tp) Time within 5 °C of Actual Peak Temp. (tp) Ramp-Down Rate Time 25 °C to Peak Temperature Pb-Free Assembly 3 °C/sec. max. 150 °C 200 °C 60-180 sec. 217 °C 60-150 sec. 260 °C 20-40 sec. 6 °C/sec. max. 8 min. max. How to Order Typical Part Marking TBU - CA 085 - 500 - WH TBU Product Series CA = Bi-Series Impulse Voltage Rating 025 = 250 V 040 = 400 V 050 = 500 V 065 = 650 V 085 = 850 V Trigger Current 050 = 50 mA 100 = 100 mA 200 = 200 mA 300 = 300 mA 500 = 500 mA Hold to Trip Ratio Suffix W = Hold to Trip Ratio Package Suffix H = DFN Package ® MANUFACTURER’S TRADEMARK PRODUCT CODE - 1ST DIGIT INDICATES PRODUCT FAMILY: A = TBU-CA SERIES - 2ND & 3RD DIGITS INDICATE IMPULSE VOLTAGE: 25 = 250 V 40 = 400 V 50 = 500 V 65 = 650 V 85 = 850 V - 4TH & 5TH DIGITS INDICATE TRIGGER CURRENT: 05 = 50 mA 10 = 100 mA 20 = 200 mA 30 = 300 mA 50 = 500 mA PIN 1 MANUFACTURING DATE CODE - 1ST DIGIT INDICATES THE YEAR’S 6-MONTH PERIOD. - 2ND DIGIT INDICATES THE WEEK NUMBER IN THE 6-MONTH PERIOD. - 3RD & 4TH DIGITS INDICATE SPECIFIC LOT FOR THE WEEK. 6-MONTH PERIOD CODES: A = JAN-JUN 2009 C = JAN-JUN 2010 B = JUL-DEC 2009 D = JUL-DEC 2010 E = JAN-JUN 2011 F = JUL-DEC 2011 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. TBU-CA Series - TBU® High Speed Protectors Packaging Specifications P0 E B t TOP COVER TAPE N D C F W D P2 A B0 K0 A0 P G (MEASURED AT HUB) USER DIRECTION OF FEED CENTER LINES OF CAVITY D1 EMBOSSMENT QUANTITY: 3000 PIECES PER REEL A Min. 326 (12.835) A0 Min. 4.3 (.169) K0 Min. 1.0 (.039) Max. 1.2 (.047) Min. 7.9 (.311) Max. 4.5 (.177) Min. 6.7 (.264) P Max. 330 (13.002) Min. 1.5 (.059) B0 B Max. 2.5 (.098) D Max. 6.9 (.272) Max. 8.1 (.319) Min. 1.5 (.059) P0 Min. 3.9 (.159) Max. 4.1 (.161) Max. 1.6 (.063) Min. 12.8 (.504) C Max. 13.5 (.531) D1 Min. 1.5 (.059) P2 Min. 1.9 (.075) Max. 2.1 (.083) Max. Min. 20.2 (.795) D Max. E Min. 1.65 (.065) t Min. 0.25 (.010) Max. 0.35 (.014) Max. 1.85 (.073) G Ref. 16.5 (.650) F Min. 7.4 (.291) W Min. 15.7 (.618) DIMENSIONS: N Ref. 102 (4.016) max. 7.6 (.299) Max. 16.3 (.642) MM (INCHES) REV. 12/16/10 “TBU” is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community. Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TBU-CA025-050-WH 价格&库存

很抱歉,暂时无法提供与“TBU-CA025-050-WH”相匹配的价格&库存,您可以联系我们找货

免费人工找货
TBU-CA025-050-WH
  •  国内价格
  • 5+10.49923
  • 750+10.18265
  • 1500+9.87857

库存:2655

TBU-CA025-050-WH
    •  国内价格
    • 1+11.09160
    • 10+9.60120
    • 30+8.67240

    库存:1