0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BZV03/Z0000/09

BZV03/Z0000/09

  • 厂商:

    BULGIN

  • 封装:

    -

  • 描述:

    PWR ENT MOD RCPT IEC320-C14 PNL

  • 数据手册
  • 价格&库存
BZV03/Z0000/09 数据手册
IEC Connectors Power Entry Modules With over 26,000 combinations Bulgin’s mains power entry modules offer a very adaptable and flexible solution to panel design. Power entry modules allow combinations of mains inlets and outlets, filtered inlets, switches, fuseholders, voltage selectors and indicators mounted in either horizontal or vertical format bezels ready for quick snap-fit assembly. The compact design occupies the minimum of panel area and a single rectangular mounting hole, offering easy installation for this mains power entry module. Our range offers a flange fixing alternative for designers who prefer the security of screw fixing. All types and variations are available through Bulgin’s extensive distribution network. Components used in Power Entry Modules. Note: Components are Approved Individually (where applicable). Please see individual component pages for full specifications. 416 IEC Connectors IEC Connectors Power Entry Modules Overview of Power Entry Modules Inlets Style C14 C14 Fused C16 C20 Snap to Panel Vertical With Single Contact switch Page 420 With Single Contact switch Page 418 With Single Contact switch Page 420 With Single Contact switch Page 424 With other components Pages 421, 422, 423 With Double Contact Switch Page 419 With other components Pages 421, 422, 423 Mini Bezel With Single Contact Switch Page 432 With Single Contact switch Page 427 Snap to Panel Horizontal Mini Bezel With Double Contact Switch Page 432 Flange Mount Vertical With Double Contact Switch Page 428 Outlets Sheet F With Single Contact switch Page 426 Inlet/ Outlet Combinations C14 C14 Fused With other components Page 425 With Single Contact switch Page 429 With Double Contact switch Page 430 No additional components Page 431 With Single Contact switch Page 433 With Double Contact switch Page 434 IEC Connectors 417 IEC Connectors C14 IEC Fused Inlet - Vertical Vertical Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Single Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BZV01/Z0000/01 How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Filtered or Non Filtered Inlet Single Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 01 = PF0011/63 02 = PF0011/28 Z0000 = Non Filtered Axxxx = Standard Single Contact Switch: 01 = S.P. Switch For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZV01/A0620/01 Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 15 = PF0033/63 16 = PF0033/28 Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) 418 IEC Connectors IEC Connectors C14 IEC Fused Inlet - Vertical Vertical Module Arrangement BZV01/Z0000/10 Fused Inlet with 2.8mm or 6.3mm tags Double Contact Switch or Indicator Variations Filtered Inlet Option Options of I/O marked switches How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components Single Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 01 = PF0011/63 02 = PF0011/28 Z0000 = Non Filtered Neon Indicator: D3 = Red Neon Indicator Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 15 = PF0033/63 16 = PF0033/28 Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZV01/A0620/10 Double Contact Switch: 10 = D.P. Switch Double Contact Neon Switch: 11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch Double Contact High Inrush Switch: 13 = D.P. High Inrush Switch Double Contact Switch Marked I/O: 70 = D.P. Switch (I/O) Double Contact Neon Switch Marked (I/O): 76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O) Double Contact High Inrush Switch Marked (I/O): 78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch (I/O) IEC Connectors 419 IEC Connectors C14 and C16 IEC Inlet - Vertical Vertical Module Arrangement Inlet with 2.8mm or 6.3mm tags Single Contact Switch or Neon Indicator Variations Filtered Inlet Option Options of I/O marked switches Non Fused BZV03/Z0000/02 How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 03 = PX0575/63 04 = PX0575/28 C16 Power Inlet (hot condition), 6.3 or 2.8mm tabs: 05 = PX0595/63 06 = PX0595/28 Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch Please note type 05 and 06 are not available in filtered version Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZV03/A0120/02 Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) 420 IEC Connectors IEC Connectors C14 and C16 IEC Inlet - Vertical Vertical Module Arrangement Inlet with 2.8mm or 6.3mm tags Double Contact Switch/ Fuseholder/Indicator/ Voltage Selectors/ Blanking Plate Filtered Inlet Option Options of I/O marked switches BZV03/Z0000/07 How to order - BZV XX XXXXX Type of Inlet / Outlet Filtered or Non Filtered Inlet C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: Z0000 = Non Filtered 03 = PX0575/63 04 = PX0575/28 For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZV03/A0120/07 C16 Power Inlet (hot condition), 6.3 or 2.8mm tabs: 05 = PX0595/63 06 = PX0595/28 Please note type 05 and 06 are not available in filtered version Axxxx = Standard XX Combination of Other Components Twin Fuseholder and Double Contact Switch: 05 = 2 x FX0359 + D.P. Switch Twin Fuseholder and Double Contact Neon Switch: 06 = 2 x FX0359 + D.P. Red Neon Switch 09 = 2 x FX0359 + D.P. Green Neon Switch 19 = 2 x FX0359 + D.P. Red Neon Switch 125V Twin Fuseholder and Neon Indicator: 07 = 2 x FX0359 + Red Neon Indicator Voltage Selector, Fuseholder and Double Contact Switch: 15 = 1 x VS0001 + 1 x FX0359 + Double Contact switch Voltage Selector, Fuseholder and Double Contact Neon Switch: 16 = 1 x VS0001 + 1 x FX0359 + D.P. Red Neon Switch 18 = 1 x VS0001 + 1 x FX0359 + D.P. Green Neon Switch Voltage Selector, Fuseholder and Neon Indicator: 17 = 1 x VS0001 + 1 x FX0359 + Red Neon Indicator Twin Fuseholder and Double Contact High Inrush Switch: 20 = 2 x FX0359 + D.P. High Inrush Switch Twin Fuseholder and Double Contact High Inrush Neon Switch: 21 = 2 x FX0359 + 1 x D.P. High Inrush Green Neon Switch 22 = 2 x FX0359 + 1 x D.P. High Inrush Red Neon Switch Voltage Selector, Neon Indicator and Double Contact Switch 25 = 1 x VS0001 + 1 x DX0928/110V/Red + D.P. Switch 26 = 1 x VS0001 + 1 x DX0928/110V/Green + D.P. Switch 27 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. Switch 28 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. Switch Voltage Selector, Neon Indicator and Double Contact High Inrush Switch: 29 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. High Inrush Switch 30 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. High Inrush Switch Fuseholder, Neon Indicator and Double Contact Switch 31 = 1 x FX0359 + 1 x DX0928/110V/Red + D.P. Switch 32 = 1 x FX0359 + 1 x DX0928/110V/Green + D.P. Switch 33 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. Switch 34 = 1 x Fx0359 + 1 x DX0928/250V/Green + D.P. Switch Fuseholder, Neon Indicator and Double Contact High Inrush Switch: 35 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. High Inrush Switch 36 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. High Inrush Switch Fuseholder, Blanking Plate and Double Contact High Inrush Neon Switch: 47 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. High Inrush Green Neon Switch Fuseholder, Blanking Plate and Double Contact Switch: 48 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. Switch IEC Connectors 421 IEC Connectors C14 and C16 IEC Inlet - Vertical Vertical Module Arrangement BZV03/Z0000/07 Inlet with 2.8mm or 6.3mm tags Double Contact Switch/ Fuseholder/Indicator/ Voltage Selectors/ Blanking Plate Filtered Inlet Option Options of I/O marked switches How to order - XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: Z0000 = Non Filtered 03 = PX0575/63 04 = PX0575/28 For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZV03/A0120/07 BZV XX C16 Power Inlet (hot condition), 6.3 or 2.8mm tabs: 05 = PX0595/63 06 = PX0595/28 Please note type 05 and 06 are not available in filtered version Axxxx = Standard Twin Fuseholder and Double Contact Switch Marked (I/O): 72 = 2 x FX0359 + D.P. Switch (I/O) Twin Fuseholder and Double Contact Neon Switch Marked (I/O): 73 = 2 x FX0359 + D.P. Red Neon Switch (I/O) 75 = 2 x FX0359 + D.P. Green Neon Switch(I/O) 82 = 2 x FX0359 + D.P. Red Neon Switch 125V(I/O) Voltage Selector, Fuseholder and Double Contact Switch Marked (I/O): 79 = 1 x VS0001 + 1 x FX0359 + Double Contact switch (I/O) Voltage Selector, Fuseholder and Double Contact Neon Switch Marked (I/O): 80 = 1 x VS0001 + 1 x FX0359 + D.P. Red Neon Switch (I/O) 81 = 1 x VS0001 + 1 x FX0359 + D.P. Green Neon Switch (I/O) Twin Fuseholder and Double Contact High Inrush Switch Marked (I/O): 83 = 2 x FX0359 + D.P. High Inrush Switch (I/O) Twin Fuseholder and Double Contact High Inrush Neon Switch Marked (I/O): 84 = 2 x FX0359 + 1 x D.P. High Inrush Green Neon Switch (I/O) 85 = 2 x FX0359 + 1 x D.P. High Inrush Red Neon Switch (I/O) Voltage Selector, Neon Indicator and Double Contact Switch Marked (I/O): 86 = 1 x VS0001 + 1 x DX0928/110V/Red + D.P. Switch (I/O) 87 = 1 x VS0001 + 1 x DX0928/110V/Green + D.P. Switch (I/O) 88 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. Switch (I/O) 89 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. Switch (I/O) 422 IEC Connectors Voltage Selector, Neon Indicator and Double Contact High Inrush Switch Marked (I/O): 90 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. High Inrush Switch(I/O) 91 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. High Inrush Switch(I/O) Fuseholder, Neon Indicator and Double Contact Switch Marked (I/O) 92 = 1 x FX0359 + 1 x DX0928/110V/Red + D.P. Switch (I/O) 93 = 1 x FX0359 + 1 x DX0928/110V/Green + D.P. Switch (I/O) 94 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. Switch (I/O) 95 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. Switch (I/O) Fuseholder, Neon Indicator and Double Contact High Inrush Switch Marked (I/O): 96 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. High Inrush Switch (I/O) 97 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. High Inrush Switch (I/O) Fuseholder, Blanking Plate and Double Contact High Inrush Neon Switch Marked (I/O): 99 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. High Inrush Green Neon Switch (I/O) Fuseholder, Blanking Plate and Double Contact Switch Marked (I/O): A0 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. Switch (I/O) B2 = 1 x VS0002 + 1 x Blanking Plate B3 = 1 x FX0359 + 1 x Blanking Plate + D.P. High Inrush Switch (I/O) B5 = 1 x VS0001 + 1 x Blanking Plate + D.P Switch (I/O) IEC Connectors C14 and C16 IEC Inlet - Vertical Vertical Module Arrangement Inlet with 2.8mm or 6.3mm tags Fuseholder/Voltage Selector/Indicator options/Blanking plate BZV04/Z0000/04 How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 03 = PX0575/63 04 = PX0575/28 Z0000 = Non Filtered Twin Fuseholder: 04 = 2 x FX0359 C16 Power Inlet (hot condition), 6.3 or 2.8mm tabs: 05 = PX0595/63 06 = PX0595/28 Please note type 05 and 06 are not available in filtered version Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZV03/A0120/04 Voltage Selector and Fuseholder: 14 = 1 x VS0001 + 1 x FX0359 Voltage selector and Neon: 37 = 1 x VS0001 + DX0928/110V/Red 38 = 1 x VS0001 + DX0928/110V/Green 39 = 1 x VS0001 + DX0928/250V/Red 40 = 1 x VS0001 + DX0928/250V/Green Fuseholder and Neon: 41 = 1 x FX0359 + DX0928/110V/Red 42 = 1 x FX0359 + DX0928/110V/Green 43 = 1 x FX0359 + DX0928/250V/Red 44 = 1 x FX0359 + DX0928/250V/Green Fuseholder and Blanking Plate: 45 = 1 x FX0359 + Blanking Plate Voltage Selector and Blanking Plate: B2 = 1 x VS0001 + Blanking Plate IEC Connectors 423 IEC Connectors C20 IEC Inlet - Vertical Vertical Module Arrangement BZV49/Z0000/69 Inlet with 4.8mm or 6.3mm tags Single Contact Switch marked I/O Illuminated, red or green, switches High inrush non-illuminated switch How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components C20 Power Inlet (cold condition), 4.8 or 6.3mm tabs: Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch 49 = PX0598/63 50 = PX0598/48 Single Contact Switch Marked (I/O): 69 = S.P. Switch (I/O) Single Contact Illuminated Switch: 02 = S.P. Illuminated Red 08 = S.P. Illuminated Green Single Contact Non-illuminated High Inrush Switch Marked I/O: 98 = S.P. High Inrush Switch (I/O) Single Contact Illuminated (Red or Green 250v Neon) Switch Marked I/O: 71 = S.P. Switch Illuminated Red (I/O) 74 = S.P. Switch Illuminated Green (I/O) 424 IEC Connectors IEC Connectors C14 IEC Inlet/Sheet F IEC Outlet - Vertical Vertical Module Arrangement Inlet/Outlet Combination 2.8mm or 6.3mm tags Filtered Inlet and Blanking Plate options Shuttered or Non-shuttered Outlet Fused BZV09/Z0000/04 How to order - BZV XX Type of Inlet / Outlet C14 Power Inlet (cold condition) and Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm tabs: 09 = PX0575/63 + PX0695/63 10 = PX0575/28 + PX0695/28 C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs: 17 = PX0575/63 + PX0783/63 18 = PX0575/28 + PX0783/28 XXXXX XX Filtered or Non Filtered Inlet Combination of Other Components Z0000 = Non Filtered Twin Fuseholder: 04 = 2 x FX0359 Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZV09/A0120/04 Voltage Selector and Fuseholder: 14 = 1 x VS0001 + 1 x FX0359 Voltage selector and Neon: 37 = 1 x VS0001 + DX0928/110V/Red 38 = 1 x VS0001 + DX0928/110V/Green 39 = 1 x VS0001 + DX0928/250V/Red 40 = 1 x VS0001 + DX0928/250V/Green Fuseholder and Neon: 41 = 1 x FX0359 + DX0928/110V/Red 42 = 1 x FX0359 + DX0928/110V/Green 43 = 1 x FX0359 + DX0928/250V/Red 44 = 1 x FX0359 + DX0928/250V/Green Fuseholder and Blanking Plate: 45 = 1 x FX0359 + Blanking Plate Voltage Selector and Blanking Plate: B2 = 1 x VS0001 + Blanking Plate IEC Connectors 425 IEC Connectors Sheet F IEC Outlet - Vertical Vertical Module Arrangement Outlet with 2.8mm or 6.3mm tags Shuttered or Non-Shuttered Single Contact Switch or Neon Indicator I/O Marking Options BZV45/Z0000/02 How to order - BZV XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components Sheet F Power Outlet (non shuttered), 6.3 or 2.8mm tabs: Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch 45 = PX0695/63 46 = PX0695/28 Sheet F Power Outlet (shuttered), 6.3 or 2.8mm tabs: 47 = PX0783/63 48 = PX0783/28 Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) 426 IEC Connectors IEC Connectors C14 IEC Fused Inlet - Horizontal Horizontal Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Single Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BZH01/Z0000/01 How to order - BZH XX Type of Inlet / Outlet Single Fused C14 Power Inlet (cold condition), 2.8 or 6.3mm tabs: 01 = PF0011/63 02 = PF0011/28 Twin Fused C14 Power Inlet (cold condition), 2.8 or 6.3mm tabs: 15 = PF0033/63 16 = PF0033/28 XXXXX XX Filtered or Non Filtered Inlet Combination of Other Components Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZH01/A0620/01 Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) IEC Connectors 427 IEC Connectors C14 IEC Fused Inlet - Horizontal Horizontal Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Double Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BZH01/Z0000/10 How to order - BZH XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components Single Fused C14 Power Inlet (cold condition), 2.8 or 6.3mm tabs: Z0000 = Non Filtered Neon Indicator: 03 = Red Neon Indicator 01 = PF0011/63 02 = PF0011/28 Twin Fused C14 Power Inlet (cold condition), 2.8 or 6.3mm tabs: 15 = PF0033/63 16 = PF0033/28 Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZH01/A0620/10 Double Contact Switch: 10 = D.P. Switch Double Contact Neon Switch: 11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch Double Contact High Inrush Switch: 13 = D.P. High Inrush Switch Double Contact Switch marked I/O: 70 = D.P. Switch (I/O) Double Contact Neon Switch Marked (I/O): 76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O) Double Contact High Inrush Switch Marked (I/O): 78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch (I/O) 428 IEC Connectors IEC Connectors C14 IEC Fused Inlet - Horizontal Horizontal Module Arrangement BZH09/Z0000/01 Inlet/Outlet Combination with 2.8mm or 6.3mm tags Shuttered or Non-Shuttered Outlet Single Contact Switch Variations Filtered Inlet Option Options of I/O marked switches How to order - BZH XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components C14 Power Inlet (cold condition) and Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm tabs: Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch 09 = PX0575/63 + PX0695/63 10 = PX0575/28 + PX0695/28 C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs: 17 = PX0575/63 + PX0783/63 18 = PX0575/28 + PX0783/28 Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZH09/A0120/01 Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) IEC Connectors 429 IEC Connectors C14 IEC Inlet/Sheet F IEC Outlet - Horizontal Horizontal Module Arrangement BZH11/Z0000/10 Inlet/Outlet Combination with 2.8mm or 6.3mm tags Single or Twin Fused Inlet Shuttered or Non-Shuttered Outlet Double Contact Switch Variations Filtered Inlet Option Options of I/O marked switches How to order - BZH XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components Single Fused C14 Power Inlet (cold condition) and Sheet F Power Outlet, 2.8 or 6.3mm tabs: Z0000 = Non Filtered Neon Indicator: D3 = Red Neon Indicator 11 = PF0011/63 + PX0695/63 12 = PF0011/28 + PX0695/28 Twin Fused C14 Power Inlet (cold condition) and Sheet F Power Outlet , 2.8 or 6.3mm tabs: 13 = PF0033/63 + PX0695/63 14 = PF0033/28 + PX0695/28 Single Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs: 19 = PF0011/63 + PX0783/63 20 = PF0011/28 + PX0783/28 Twin Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs: 21 = PF0033/63 + PX0783/63 22 = PF0033/28 + PX0783/28 430 IEC Connectors Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZH11/A0620/10 Double Contact Switch: 10 = D.P. Switch Double Contact Neon Switch: 11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch Double Contact High Inrush Switch: 13 = D.P. High Inrush Switch Double Contact Switch Marked I/O: 70 = D.P. Switch (I/O) Double Contact Neon Switch Marked (I/O): 76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O) Double Contact High Inrush Switch Marked (I/O): 78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch (I/O) IEC Connectors C14 IEC Inlet/Sheet F IEC Outlet - Horizontal Horizontal Module Arrangement Fused Inlet/Outlet Combination with 2.8mm or 6.3mm tags Filtered Inlet Option Single or Twin Fused BZH11/Z0000/00 How to order - BZH XX XXXXX XX Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components Single Fused C14 Power Inlet (cold condition) and Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm tabs: Z0000 = Non Filtered None Axxxx = Standard 00 = None 11 = PF0011/63 + PX0695/63 12 = PF0011/28 + PX0695/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BZH11/A0620/00 Twin Fused C14 Power Inlet (cold condition) and Sheet F Non-shuttered Power Outlet , 2.8 or 6.3mm tabs: 13 = PF0033/63 + PX0695/63 14 = PF0033/28 + PX0695/28 Single Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs: 19 = PF0011/63 + PX0783/63 20 = PF0011/28 + PX0783/28 Twin Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs: 21 = PF0033/63 + PX0783/63 22 = PF0033/28 + PX0783/28 IEC Connectors 431 IEC Connectors C14 IEC Inlet - Mini Bezel Minimum Combined Bezel Size Inlet with 2.8, 4.8 or 6.3mm tags Horizontal Module Arrangement Single and Double Contact Switch Variations Filtered Inlet Option BZM27/Z0000/57B How to order - BZM XX XXXXX XX X Type of Inlet / Outlet Filtered or Non Filtered Inlet Switch Variation Panel Thickness C14 Power Inlet (cold condition), 6.3, 4.8 & 2.8mm tabs: Z0000 = Non Filtered Single Contact Switch, 4.8mm or solder tab, marked I/O: 53 = S.P. Switch, 4.8mm tab (I/O) 54 = S.P. Switch, solder tab (I/O) 27 = PX0575/63 42 = PX0575/48 28 = PX0575/28 For Filtered inlet use 6th to 9th characters from filter ordering code see page 435 E.g. BZM27/A0120/57B 1.0mm = A 1.5mm = B 2.0mm = C 3.0mm = D Axxxx = Standard Single Contact Illuminated Switch, 4.8mm or solder tab: 55 = S.P. Switch Illum. Red, 4.8mm tab 61 = S.P. Switch Illum. Green, 4.8mm tab 56 = S.P. Switch Illum. Red, solder tab 62 = S.P. Switch Illum. Green, solder tab Double Contact Switch, 4.8mm or solder tab, marked I/O: 57 = D.P. Switch, 4.8mm tab (I/O) 58 = D.P. Switch, solder tab (I/O) Double Contact Illuminated Switch, 4.8mm or solder tab: 59 = D.P. Switch Illum. Red, 4.8mm tab 63 = D.P. Switch Illum. Green, 4.8mm tab 60 = D.P. Switch Illum. Red, solder tab 64 = D.P. Switch Illum. Green, solder tab Double Contact High Inrush, 4.8mm tabs: 65 = D.P. High Inrush Switch, 4.8mm tabs (S.P. format) Double Contact High Inrush, 4.8mm tabs, marked I/O: 68 = D.P. High Inrush Switch, 4.8mm tabs, I/O (S.P. format) Single Contact Illuminated Switch, 4.8mm or solder tab, Marked I/O: A1 = S.P. Switch Illum. Red, 4.8mm tab (I/O) A5 = S.P. Switch Illum. Green, 4.8mm tab (I/O) A2 = S.P. Switch Illum. Red, solder tab (I/O) A6 = S.P. Switch Illum. Green, solder tab (I/O) Double Contact Illuminated Switch, 4.8mm or solder tab, Marked I/O: A3 = D.P. Switch Illum. Red, 4.8mm tab A7 = D.P. Switch Illum. Green, 4.8mm tab A4 = D.P. Switch Illum. Red, solder tab A8 = D.P. Switch Illum. Green, solder tab 432 IEC Connectors IEC Connectors C14 IEC Fused Inlet - Polyflange Vertical Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Screw Fixing to Panel Single Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BVA01/Z0000/02 Vertical Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Screw Fixing to Panel Single Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BVB01/Z0000/01 How to order - BV X XX XXXXX XX Flange Type Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components A = Top fixing Single Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: Z0000 = Non Filtered Single Contact Switch: 01 = S.P. Switch 01 = PF0011/63 02 = PF0011/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BVA01/A0620/01 B = Side fixing Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 15 = PF0033/63 16 = PF0033/28 Axxxx = Standard Single Contact Neon Switch: 02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch Neon Indicator: 03 = Red Neon Indicator Single Contact High Inrush Switch: 46 = S.P. High Inrush Switch Single Contact Switch Marked I/O: 69 = S.P. Switch (I/O) Single Contact Neon Switch Marked (I/O): 71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O) Single Contact High Inrush Switch Marked (I/O): 98 = S.P. High Inrush Switch (I/O) IEC Connectors 433 IEC Connectors C14 IEC Fused Inlet - Polyflange Vertical Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Screw Fixing to Panel Double Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BVA01/Z0000/10 Vertical Module Arrangement Fused Inlet with 2.8mm or 6.3mm tags Screw Fixing to Panel Double Contact Switch Variations Filtered Inlet Option Options of I/O marked switches BVB01/Z0000/11 How to order - BV X XX XXXXX XX Flange Type Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components A = Top fixing Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: Z0000 = Non Filtered Neon Indicator: D3 = Red Neon Indicator B = Side fixing 01 = PF0011/63 02 = PF0011/28 Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm tabs: 15 = PF0033/63 16 = PF0033/28 Axxxx = Standard For Filtered inlet use 6th to 9th characters from filter ordering code see pages 436 - 437 E.g. BVA01/A0620/10 Double Contact Switch: 10 = D.P. Switch Double Contact Neon Switch: 11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch Double Contact High Inrush Switch: 13 = D.P. High Inrush Switch Double Contact Switch Marked I/O: 70 = D.P. Switch (I/O) Double Contact Neon Switch Marked (I/O): 76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O) Double Contact High Inrush Switch Marked (I/O): 78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch (I/O) 434 IEC Connectors IEC Connectors C14 IEC Fused Inlet EMI Filter Options For Polysnap modules BZV03, BZV04, BZV09, BZV10, BZV17, BZV18, BZH09, BZH10, BZH17, BZH18, BZM27, BZM28 PX0575 style IEC inlet Using PS01/A style filter Standard Attenuation Filter BVA01/Z0000/10 How to order - A B XXXX XX X X Polysnap Part No. Filter Type Rating L/C Circuit Additional Components From Polysnap Selection A = Standard 01 = 1A 1 = Version 1 0 = None 03 = 3A 2 = Version 2 06 = 6A 3 = Version 3 XX Polysnap Part No. From Polysnap Selection 10 = 10A Rating Version L1 Cx Cy Part No. Example 1 AMP “ “ 1 2 3 2 x 2.8mH 2 x 10mH 2 x 10mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF BZV03/A0120/02 3 AMP “ “ 1 2 3 2 x 0.75mH 2 x 1.8mH 2 x 1.8mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 6 AMP “ “ 1 2 3 2 x 0.3mH 2 x 0.7mH 2 x 0.7mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 10 AMP “ “ 1 2 3 2 x 0.17mH 2 x 0.35mH 2 x 0.17mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF BZV style Polysnap module with PX0575 IEC power inlet, filter rated at 1 amp, L/C circuit version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF, Cy = 2 x 2.2nF) 6.3mm tabs and single Contact red neon switch. Filter Specification Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage: 250V a.c. 50-400Hz
BZV03/Z0000/09 价格&库存

很抱歉,暂时无法提供与“BZV03/Z0000/09”相匹配的价格&库存,您可以联系我们找货

免费人工找货
BZV03/Z0000/09
    •  国内价格
    • 5+179.48123
    • 25+155.84224
    • 55+140.08291

    库存:0

    BZV03/Z0000/09
      •  国内价格 香港价格
      • 1+118.992181+14.42317
      • 4+118.436144+14.35577
      • 20+118.4335220+14.35545
      • 40+118.4308940+14.35513
      • 125+118.42828125+14.35482

      库存:0