Maintenance indicator 1430 Smart indicator series
៉ Monitors appliance usage
230Vac. 115Vac, 48V, 24V & 12V available.
Less than 1 watt (power consumption)
៉ Preventative maintenance reminder
៉ Direct replacement for Neon indicator
UL Recognised. File no. E311309
៉ Counts time that mains power is applied
៉ Remembers accumulated time even if
៉
៉
៉
៉
៉
៉
power is switched off
Connecting ‘reset’ terminal to Neutral
resets timer to zero
Green LED indicates normal operation
Flashing Red LED indicates service
action is required
Convenient snap-in design
Choice of connection terminals
Panel cut out:
30.0 x 11.0
CE Mark
FCC compliant
RoHS
RoHS compliant
C 1432 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, TIME
TERMINAL
BODY & DIMENSIONS
Dimensions
L Panel Cut-Out
C
30.0
30.1
6.3 x 0.8
H
11.0/11.1
Bezel
4.8 x 0.8
Panel thickness
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
0.75mm to 2.5mm
Body
Lens
Terminals
Flame retardancy
RoHS compliant
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
Copper alloy, Silver plated
UL94V0
Yes
Operating supply
230V ±20% 50/60Hz.
115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc &
12Vac available
Less than 1 Watt
R1.0
32.0
T
14.0
Ø2.1
SPECIFICATION
Power consumption
Operating conditions (body)
-20°C to +70°C (-4°F to 158°F)
0 to 95% RH (non-condensing)
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EMC Emissions
EN 55014-1:2001
Household appliances
EN 55022 Class B:1998 Domestic environments
Timing period
Timing accuracy
Any period from 1 minute to greater than 10 years
2% of scale
Approvals
UL Recognised
CE Mark
FCC Compliant
Standards
UL 508
CSA C22.2 No. 14-05
Dimensions
Solder
2.0
X
25.3 Max
4.0
electronics
PCB 0.8Sq
90
All dimensions in millimetres (mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 91
APPLICATIONS
OPERATION
The smart indicator operates like a standard neon indicator, giving visible status
indication for the appliance or application. Normal operation will show continuous
Green LED illumination (contact sales for other colours).
៉ Coffee machines – decalcification
៉ Deep fat fryer – oil change
៉ Air conditioning – filter change, bleaching
៉ Vacuum cleaner – filter cleaning
៉ Motorised equipment – preventative maintenance, lubrication, belt
change
When the accrued usage time exceeds the factory-set time limit, the LED illumination
changes colour to Red (contact sales for other colours) and starts to flash on/off to
attract user attention. The indicator will continue to flash on subsequent appliance use,
until the maintenance operation is carried out and the reset procedure followed.
៉ Petrol/Diesel engine generator – engine service
៉ Central heating – gas appliance inspection
៉ Inspection/cleaning interval reminder – washrooms, kitchens
៉ Equipment calibration interval reminder
To reset the indicator after maintenance operations are completed, simply link terminal
3 to terminal 4 while the indicator is powered. This could be a key-operated switch or a
service button within the appliance.
The service interval time is factory programmed, and can be any time period from as
little as one minute, up to tens of years.
៉ Electrical safety check interval reminder
CONNECTIONS
PART NUMBER
1
Live
3
Reset Switch
4
1432AL
Neutral
Specify Terminal Type:
Specify Model Code:
Specify Supply Voltage:
Specify LED Colour:
Specify Time Setting:
C, H, T, X
1432AL
230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc,
12Vac
Green/Red, Blue/Red
Time interval between 1 minute and 10 years.
Specify the required time in minutes, hours, days,
weeks or months.
electronics
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
91
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 92
Temperature monitor 1430 Smart indicator series
៉ Monitors refrigeration temperatures are
230Vac, 115Vac, 48V, 24V & 12V available
Less than 1 watt (power consumption)
within safe limits
៉ Monitors correct equipment operation
៉ Factory programmed window limits
UL Recognised. File no. E311309
៉ Direct replacement for Neon indicator
CE Mark
៉ Thermistor temperature sensor
៉ Blue LED indicates normal temperature
FCC compliant
៉ Flashing Red LED indicates too hot
៉ Flashing Blue LED indicates too cool
៉ Convenient snap-in design
RoHS
RoHS compliant
៉ Choice of connection terminals
៉ Panel cut out:
30.0 x 11.0
C 1433 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, TEMPERATURES
TERMINAL
C
BODY & DIMENSIONS
L Panel Cut-Out
Dimensions
30.0
30.1
6.3 x 0.8
H
SPECIFICATION
11.0/11.1
Panel thickness
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
0.75mm to 2.5mm
Body
Lens
Terminals
Flame retardancy
RoHS compliant
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
Copper alloy, Silver plated
UL94V0
Yes
Operating supply
230Vac ±20% 50/60Hz.
115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc &
12Vac available
Less than 1 Watt
Bezel
4.8 x 0.8
R1.0
32.0
T
14.0
Ø2.1
Dimensions
Power consumption
Operating conditions (body)
–20°C to +70°C (–4°F to 158°F)
0 to 95% RH (non-condensing)
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EMC Emissions
EN 55014-1:2001
Household appliances
EN 55022 Class B:1998 Domestic environments
Measurement range
Measurement accuracy
Temperature sensor
–30ºC to +80ºC (–22ºF to +176ºF)
±1.0ºC (±1.8F)
NTC Thermistor, sealed sensor, cable length 1m
Approvals
UL Recognised
FCC Compliant
CE Mark
Standards
UL 508
CSA C22.2 No. 14-05
Solder
2.0
25.3 Max
X
4.0
electronics
PCB 0.8Sq
92
All dimensions in millimetres (mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 93
APPLICATIONS
INDICATIONS
៉ Deep freeze monitoring - visual check of correct temperature
៉ Cold storage monitor - visual check of correct temperature
៉ Refrigeration monitoring - visual check of correct temperature
៉ Chiller monitor - visual check of correct temperature
៉ Air conditioning - status indicator
៉ Equipment check - without having to know exact temperature
Upper and lower temperature limits can be sales programmed to suit the application.
The smart indicator operates like a standard neon indicator, giving visible status
indication for the appliance or application. Normal operation will show continuous Blue
LED illumination (contact sales for other colours) while the monitored temperature is
within the ‘safe’ range between lower and upper limits.
When the measured temperature falls outside of the ‘safe’ range, the LED illumination
will start to flash or change colour. (contact sales for colour options).
Example temperatures (Freezer):
Above -14°C
Between -14°C and -22°C
Below -22°C
Too warm (Flashing Red LED)
OK (Blue LED)
Too cold (Flashing Blue LED)
Optional steady/flashing LED and colour combinations available – contact sales.
PART NUMBER
CONNECTIONS
Live
Specify Terminal Type:
Specify Model Code:
Specify Supply Voltage:
3
4
1433AL
1
2
Thermistor
Neutral
Specify LED Colour:
Specify Lower temperature limit:
Specify Upper temperature limit:
C, H, T, X
1433AL
230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac,
12Vdc, 12Vac
Blue/Red, Green/Red
–30ºC to +80ºC (–22ºF +176ºF)
–30ºC to +80ºC (–22ºF +176ºF)
electronics
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
93
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 94
Status monitor 1430 Smart indicator series
៉ Monitors many NO switch contacts
230Vac, 115Vac, 48V, 24V & 12V available
Less than 1 watt (power consumption)
៉ Monitors correct equipment operation
៉ Direct replacement for Neon indicator
UL Recognised. File no. E311309
៉ Green LED indicates normal status
៉ Flashing Red LED indicates alarm status
CE Mark
៉ De-bounce, time delay and latching
options
FCC compliant
៉ Convenient snap-in design
៉ Choice of connection terminals
៉ Panel cut out:
RoHS
RoHS compliant
30.0 x 11.0
C 1437 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, FUNCTION
TERMINAL
C
BODY & DIMENSIONS
Panel Cut-Out
Dimensions
30.0
30.1
6.3 x 0.8
H
SPECIFICATION
11.0/11.1
Panel thickness
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
0.75mm to 2.5mm
Body
Lens
Terminals
Flame retardancy
RoHS compliant
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
Copper alloy, Silver plated
UL94V0
Yes
Sensor/Switch Input
Non-isolated 4.2Vdc 1mA rating for detection of
normally open, normally closed or open-collector
sensors
Operating supply
230Vac ±20% 50/60Hz.
115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc &
12Vac available
Less than 1 Watt
Bezel
4.8 x 0.8
R1.0
32.0
T
14.0
Ø2.1
Power consumption
Dimensions
Solder
2.0
X
4.0
Operating conditions (body)
–20°C to +70°C (–4°F to 158°F)
0 to 95% RH (non-condensing)
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EMC Emissions
EN 55014-1:2001
Household appliances
EN 55022 Class B:1998 Domestic environments
Approvals
UL Recognised
FCC Compliant
CE Mark
Standards
UL 508
CSA C22.2 No. 14-05
25.3 Max
electronics
PCB 0.8Sq
94
All dimensions in millimetres (mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 95
APPLICATIONS
INDICATIONS
៉ Limit switch detection and display – machine position
៉ Differential air pressure sensing - filter status indicator
៉ Latching and display of momentary sensor signals
The smart indicator operates like a standard neon indicator, giving visible status
indication for the application. Normal operation shows a continuous Green LED
illumination (contact sales for other colours) while an error or fault condition results in a
RED illumination. Fault condition indication can be factory configured as flashing.
Status indicators are commonly used on equipment and machinery to advise the
operator that particular device conditions are normal, operational status is active or
inactive, equipment is on-line or off-line. Various standard switches and sensors can be
used to determine position, location, rotation speed, airflow, air pressure, vacuum level,
interlock etc.
The indicators’ sensing input provides a non-isolated DC voltage, current limited to
1mA, for detection of volt-free normally open or normally closed switch contacts, or
open-collector type sensors.
Some switches can exhibit transient effects or require de-bounce functions, most of
which can be masked by having a qualifying time period before the indication takes
place. In some applications a hold-off delay could be useful to ignore any settling
during initial operation, or indications may only be required after power-up and then
latched. The indicator can be factory programmed to cater for many different
requirements, please contact us with application details.
PART NUMBER
CONNECTIONS
Live
1
Specify Terminal Type:
Specify Model Code:
Specify Supply Voltage:
Sensor/Switch Contact
2
3
4
1437AL
Neutral
Specify LED Colour:
Specify application requirements:
C, H, T, X
1437AL
230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac,
12Vdc, 12Vac
Green/Red, Blue/Red
Normally open/closed contact, time delay,
latching etc.
electronics
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
95
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:55
Page 96
Single phase mains supply checker 1430 Smart indicator series
៉ Monitors appliance and mains supply
230V 50Hz. 115Vac 60Hz available.
Less than 1 watt (power consumption)
៉ Direct replacement for Neon indicator
៉ Equipment safety indication
UL Recognised. File no. E311309
៉ Checks for swapped connections
៉ Checks for missing connections
CE Mark
៉ Green LED indicates normal operation
៉ Steady Red LED indicates connection
៉
៉
៉
៉
៉
fault
Flashing Red LED indicates missing
connection
Live, Neutral and Earth connections
Convenient snap-in design
Fast-on terminals
Panel cut out:
30.0 x 11.0
FCC compliant
RoHS
RoHS compliant
C 1431 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY
TERMINAL
BODY & DIMENSIONS
L Panel Cut-Out
C
H
SPECIFICATION
Dimensions
30.0
30.1
6.3 x 0.8
11.0/11.1
Bezel
4.8 x 0.8
VOLTAGE, COLOUR
R1.0
Panel thickness
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
0.75mm to 2.5mm
Body
Lens
Terminals
Flame retardancy
RoHS compliant
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
Copper alloy, Silver plated
UL94V0
Yes
Operating supply
Power consumption
230V ±20% 50Hz. 115V 60Hz available
Less than 1 Watt
Operating conditions (body)
-20°C to +70°C (-4°F to 158°F)
0 to 95% RH (non-condensing)
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EMC Emissions
EN 55014-1:2001
Household appliances
EN 55022 Class B:1998 Domestic environments
Approvals
UL Recognised
FCC Compliant
CE Mark
Standards
UL 508
CSA C22.2 No. 14-05
32.0
T
14.0
Ø2.1
Dimensions
Solder
2.0
25.3 Max
X
4.0
electronics
PCB 0.8Sq
96
All dimensions in millimetres (mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:56
Page 97
APPLICATIONS
INDICATIONS
The smart indicator can detect and display the following fault conditions:
៉ Portable appliances
៉ Site equipment
Terminal 1
Terminal4
Terminal 3
៉ Commercial kitchens
L
N
E
Normal
Green
៉ Stainless steel appliances
N
L
E
L/N Swapped
Red
E
N
L
L/E Swapped
Red
៉ Extension cables/reels
E
L
N
Wrong sequence
Red
៉ Garden equipment
N
E
L
Wrong sequence
Red
L
-
E
Neutral missing
Flashing Red
L
N
-
Earth missing
Flashing Red
៉ Power tools
៉ Audio equipment
៉ Consumer units
CONNECTIONS
Fault
LED Indication
PART NUMBER
1
Live
3
Earth
4
1431AL
Neutral
Specify Terminal Type:
Specify Model Code:
Specify Supply Voltage:
Specify LED Colour:
C, H, T, X
1431AL
115Vac, 230Vac
Green/Red, Blue/Red
electronics
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
97
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:56
Page 98
Temperature Micro Logger 1430 Smart indicator series
៉ Intelligent temperature logger for
100 to 230Vac ±20% 50/60Hz.
Less than 1 watt (power consumption)
refrigeration
៉ Wireless data communication
៉ Over 14,000 data readings stored
UL Recognised. File no. E311309
៉ Non-volatile memory
CE Mark
៉ Industry standard Thermistor supplied
៉ Configurable data log interval
FCC compliant
៉ Monitors mains power interruptions
៉ Programmable upper/lower limit alarm
៉ Blue LED indicates normal operation
RoHS
RoHS compliant
៉ Red LED indicates problem
៉ Snap-in mounting
៉ Panel cut out:
30.0 x 11.0
C 1435 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY COLOUR
TERMINAL
BODY & DIMENSIONS
L Panel Cut-Out
C
Dimensions
30.0
30.1
6.3 x 0.8
H
11.0/11.1
Bezel
4.8 x 0.8
T
R1.0
Dimensions
Solder
66
X
4.0
Panel thickness
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
0.75mm to 2.5mm
Body
Lens
Terminals
Flame retardancy
RoHS compliant
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
Copper alloy, Silver plated
UL94V-0
Yes
Operating supply
Power consumption
100 to 230Vac ±20% 50/60Hz.
Less than 1 Watt
Operating conditions (body)
–20°C to +70°C (–4°F to 158°F)
0 to 95% RH (non-condensing)
Measurement range
Measurement accuracy
Measurement resolution
Temperature sensor
–30ºC to +80ºC (–22ºF to +176ºF)
±1.0ºC (±1.8F)
±0.5ºC (±0.9ºF)
NTC Thermistor, sealed sensor, cable length 1m
Communications method
Logging Interval
Logging data capacity
Data retention
Infrared serial data port
Programmable 1 second to 12 hours per reading
>14,000 measurements stored
>10 years without power
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EMC Emissions
EN 55014-1:2001
Household appliances
EN 55022 Class B:1998 Domestic environments
Approvals
UL Recognised
FCC compliant
CE Mark
Standards
UL 508
CSA C22.2 No. 14-05
32.0
14.0
Ø2.1
SPECIFICATION
electronics
PCB 0.8Sq
98
All dimensions in millimetres (mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds
19/11/09
13:56
Page 99
APPLICATIONS
INDICATIONS
An Intelligent temperature data logging device for refrigeration applications, ideal for
monitoring that freezers and chillers are maintaining the required temperatures to
comply with food safety guidelines.
៉ Refrigeration temperature monitoring for food safety compliance
៉ Deep freeze monitoring
៉ Cold storage monitor
Designed to directly replace the standard neon indicator already fitted on many
appliances, the front-panel mounted temperature logger operates like a standard neon
indicator, giving visible status indication for the appliance or application. Normal
operation will show continuous blue LED illumination (contact sales for other colours)
while the monitored temperature is within the ‘safe’ range between lower and upper
limits. The upper and lower temperature limits for alarm indication are fully user
programmable.
៉ Chiller monitoring
៉ Process control temperature monitoring
៉ Visual checking of correct temperature
៉ Control system verification – independent monitoring of controller
៉ Power quality indication – records power interruptions
៉ Equipment status check - simple indicator lights
The embedded microcontroller stores the temperature readings at regular intervals for
retrieval and analysis. Over 14,000 readings can be stored in non-volatile memory (no
battery is required). The data log interval is user configurable between 1 second and
12 hours. The logger also records the number of mains power interruptions. Stored
data can be transferred to a collection device (PDA or Laptop) via a wireless infrared
data link, a serial to infared communication adapter is available as an accessory.
The device is provided with an industry standard Thermistor temperature sensor.
PC and PDA software can be downloaded from www.arcolectric.co.uk/software
CONNECTIONS
PART NUMBERS
1435AL
Specify Terminal Type:
Specify Model Code:
Specify LED Colour:
3
4
Live
C, H, T, X
1435AL
Green/Red, Blue/Red
2
Thermistor
1
Neutral
SOFTWARE
The PC software allows fast and simple configuration of the temperature
micro logger device settings. The stored temperature data can be easily
extracted using a serial port infrared data link.
With a single button press, the ‘Download log’ feature imports the stored
temperature reading data directly into an Excel spreadsheet for easy analysis
and display.
The logging time interval can be set to suit the end application.
Low and high alarm setpoints can be fully configured for LED indication on
the logger front panel. When the measured temperature is between the low
and high limits, the Blue LED illuminates to indicate that the measured
temperature is acceptable. When the measured temperature falls outside of
low or high alarm setpoint, the LED illumination changes colour to Red.
Additionally, if the alarm memory box is checked, the only way to clear a
temperature alarm is to press the ‘Alarm Clear’ button.
The Logger status is continually updated while the infrared data link is active,
and the current measured temperature is displayed in °C or °F.
electronics
Memory usage can also be monitored.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
99