0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
C1435ALMAA

C1435ALMAA

  • 厂商:

    BULGIN

  • 封装:

    -

  • 描述:

    Sensor Output

  • 数据手册
  • 价格&库存
C1435ALMAA 数据手册
CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 90 Maintenance indicator 1430 Smart indicator series ៉ Monitors appliance usage 230Vac. 115Vac, 48V, 24V & 12V available. Less than 1 watt (power consumption) ៉ Preventative maintenance reminder ៉ Direct replacement for Neon indicator UL Recognised. File no. E311309 ៉ Counts time that mains power is applied ៉ Remembers accumulated time even if ៉ ៉ ៉ ៉ ៉ ៉ power is switched off Connecting ‘reset’ terminal to Neutral resets timer to zero Green LED indicates normal operation Flashing Red LED indicates service action is required Convenient snap-in design Choice of connection terminals Panel cut out: 30.0 x 11.0 CE Mark FCC compliant RoHS RoHS compliant C 1432 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, TIME TERMINAL BODY & DIMENSIONS Dimensions L Panel Cut-Out C 30.0 30.1 6.3 x 0.8 H 11.0/11.1 Bezel 4.8 x 0.8 Panel thickness Bezel 32.0mm x 14.0mm Panel cut-out 11.0/11.1mm x 30.0/30.1mm 0.75mm to 2.5mm Body Lens Terminals Flame retardancy RoHS compliant Nylon 6.6, matt finish, black colour is standard Clear Polycarbonate, Softline matt finish Copper alloy, Silver plated UL94V0 Yes Operating supply 230V ±20% 50/60Hz. 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc & 12Vac available Less than 1 Watt R1.0 32.0 T 14.0 Ø2.1 SPECIFICATION Power consumption Operating conditions (body) -20°C to +70°C (-4°F to 158°F) 0 to 95% RH (non-condensing) Electromagnetic Compatibility Compliant with directives 89/336/EEC & 92/31/EEC EMC Immunity EN 55014-2:1997 Household appliances EN 61000-6-2:2005 Industrial Environments,10 V/m EN 61000-4-2:1995 Electrostatic Discharges (ESD) EN 61000-4-3:2002 RF Electromagnetic fields EN 61000-4-4:2004 Fast Transients & Bursts EN 61000-4-5:1995 Surges EN 61000-4-6:1996 Conducted disturbances EN 61000-4-11:2004 Voltage dips & interruptions EMC Emissions EN 55014-1:2001 Household appliances EN 55022 Class B:1998 Domestic environments Timing period Timing accuracy Any period from 1 minute to greater than 10 years 2% of scale Approvals UL Recognised CE Mark FCC Compliant Standards UL 508 CSA C22.2 No. 14-05 Dimensions Solder 2.0 X 25.3 Max 4.0 electronics PCB 0.8Sq 90 All dimensions in millimetres (mm) tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 91 APPLICATIONS OPERATION The smart indicator operates like a standard neon indicator, giving visible status indication for the appliance or application. Normal operation will show continuous Green LED illumination (contact sales for other colours). ៉ Coffee machines – decalcification ៉ Deep fat fryer – oil change ៉ Air conditioning – filter change, bleaching ៉ Vacuum cleaner – filter cleaning ៉ Motorised equipment – preventative maintenance, lubrication, belt change When the accrued usage time exceeds the factory-set time limit, the LED illumination changes colour to Red (contact sales for other colours) and starts to flash on/off to attract user attention. The indicator will continue to flash on subsequent appliance use, until the maintenance operation is carried out and the reset procedure followed. ៉ Petrol/Diesel engine generator – engine service ៉ Central heating – gas appliance inspection ៉ Inspection/cleaning interval reminder – washrooms, kitchens ៉ Equipment calibration interval reminder To reset the indicator after maintenance operations are completed, simply link terminal 3 to terminal 4 while the indicator is powered. This could be a key-operated switch or a service button within the appliance. The service interval time is factory programmed, and can be any time period from as little as one minute, up to tens of years. ៉ Electrical safety check interval reminder CONNECTIONS PART NUMBER 1 Live 3 Reset Switch 4 1432AL Neutral Specify Terminal Type: Specify Model Code: Specify Supply Voltage: Specify LED Colour: Specify Time Setting: C, H, T, X 1432AL 230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc, 12Vac Green/Red, Blue/Red Time interval between 1 minute and 10 years. Specify the required time in minutes, hours, days, weeks or months. electronics tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk 91 CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 92 Temperature monitor 1430 Smart indicator series ៉ Monitors refrigeration temperatures are 230Vac, 115Vac, 48V, 24V & 12V available Less than 1 watt (power consumption) within safe limits ៉ Monitors correct equipment operation ៉ Factory programmed window limits UL Recognised. File no. E311309 ៉ Direct replacement for Neon indicator CE Mark ៉ Thermistor temperature sensor ៉ Blue LED indicates normal temperature FCC compliant ៉ Flashing Red LED indicates too hot ៉ Flashing Blue LED indicates too cool ៉ Convenient snap-in design RoHS RoHS compliant ៉ Choice of connection terminals ៉ Panel cut out: 30.0 x 11.0 C 1433 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, TEMPERATURES TERMINAL C BODY & DIMENSIONS L Panel Cut-Out Dimensions 30.0 30.1 6.3 x 0.8 H SPECIFICATION 11.0/11.1 Panel thickness Bezel 32.0mm x 14.0mm Panel cut-out 11.0/11.1mm x 30.0/30.1mm 0.75mm to 2.5mm Body Lens Terminals Flame retardancy RoHS compliant Nylon 6.6, matt finish, black colour is standard Clear Polycarbonate, Softline matt finish Copper alloy, Silver plated UL94V0 Yes Operating supply 230Vac ±20% 50/60Hz. 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc & 12Vac available Less than 1 Watt Bezel 4.8 x 0.8 R1.0 32.0 T 14.0 Ø2.1 Dimensions Power consumption Operating conditions (body) –20°C to +70°C (–4°F to 158°F) 0 to 95% RH (non-condensing) Electromagnetic Compatibility Compliant with directives 89/336/EEC & 92/31/EEC EMC Immunity EN 55014-2:1997 Household appliances EN 61000-6-2:2005 Industrial Environments,10 V/m EN 61000-4-2:1995 Electrostatic Discharges (ESD) EN 61000-4-3:2002 RF Electromagnetic fields EN 61000-4-4:2004 Fast Transients & Bursts EN 61000-4-5:1995 Surges EN 61000-4-6:1996 Conducted disturbances EN 61000-4-11:2004 Voltage dips & interruptions EMC Emissions EN 55014-1:2001 Household appliances EN 55022 Class B:1998 Domestic environments Measurement range Measurement accuracy Temperature sensor –30ºC to +80ºC (–22ºF to +176ºF) ±1.0ºC (±1.8F) NTC Thermistor, sealed sensor, cable length 1m Approvals UL Recognised FCC Compliant CE Mark Standards UL 508 CSA C22.2 No. 14-05 Solder 2.0 25.3 Max X 4.0 electronics PCB 0.8Sq 92 All dimensions in millimetres (mm) tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 93 APPLICATIONS INDICATIONS ៉ Deep freeze monitoring - visual check of correct temperature ៉ Cold storage monitor - visual check of correct temperature ៉ Refrigeration monitoring - visual check of correct temperature ៉ Chiller monitor - visual check of correct temperature ៉ Air conditioning - status indicator ៉ Equipment check - without having to know exact temperature Upper and lower temperature limits can be sales programmed to suit the application. The smart indicator operates like a standard neon indicator, giving visible status indication for the appliance or application. Normal operation will show continuous Blue LED illumination (contact sales for other colours) while the monitored temperature is within the ‘safe’ range between lower and upper limits. When the measured temperature falls outside of the ‘safe’ range, the LED illumination will start to flash or change colour. (contact sales for colour options). Example temperatures (Freezer): Above -14°C Between -14°C and -22°C Below -22°C Too warm (Flashing Red LED) OK (Blue LED) Too cold (Flashing Blue LED) Optional steady/flashing LED and colour combinations available – contact sales. PART NUMBER CONNECTIONS Live Specify Terminal Type: Specify Model Code: Specify Supply Voltage: 3 4 1433AL 1 2 Thermistor Neutral Specify LED Colour: Specify Lower temperature limit: Specify Upper temperature limit: C, H, T, X 1433AL 230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc, 12Vac Blue/Red, Green/Red –30ºC to +80ºC (–22ºF +176ºF) –30ºC to +80ºC (–22ºF +176ºF) electronics tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk 93 CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 94 Status monitor 1430 Smart indicator series ៉ Monitors many NO switch contacts 230Vac, 115Vac, 48V, 24V & 12V available Less than 1 watt (power consumption) ៉ Monitors correct equipment operation ៉ Direct replacement for Neon indicator UL Recognised. File no. E311309 ៉ Green LED indicates normal status ៉ Flashing Red LED indicates alarm status CE Mark ៉ De-bounce, time delay and latching options FCC compliant ៉ Convenient snap-in design ៉ Choice of connection terminals ៉ Panel cut out: RoHS RoHS compliant 30.0 x 11.0 C 1437 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY VOLTAGE, COLOUR, FUNCTION TERMINAL C BODY & DIMENSIONS Panel Cut-Out Dimensions 30.0 30.1 6.3 x 0.8 H SPECIFICATION 11.0/11.1 Panel thickness Bezel 32.0mm x 14.0mm Panel cut-out 11.0/11.1mm x 30.0/30.1mm 0.75mm to 2.5mm Body Lens Terminals Flame retardancy RoHS compliant Nylon 6.6, matt finish, black colour is standard Clear Polycarbonate, Softline matt finish Copper alloy, Silver plated UL94V0 Yes Sensor/Switch Input Non-isolated 4.2Vdc 1mA rating for detection of normally open, normally closed or open-collector sensors Operating supply 230Vac ±20% 50/60Hz. 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc & 12Vac available Less than 1 Watt Bezel 4.8 x 0.8 R1.0 32.0 T 14.0 Ø2.1 Power consumption Dimensions Solder 2.0 X 4.0 Operating conditions (body) –20°C to +70°C (–4°F to 158°F) 0 to 95% RH (non-condensing) Electromagnetic Compatibility Compliant with directives 89/336/EEC & 92/31/EEC EMC Immunity EN 55014-2:1997 Household appliances EN 61000-6-2:2005 Industrial Environments,10 V/m EN 61000-4-2:1995 Electrostatic Discharges (ESD) EN 61000-4-3:2002 RF Electromagnetic fields EN 61000-4-4:2004 Fast Transients & Bursts EN 61000-4-5:1995 Surges EN 61000-4-6:1996 Conducted disturbances EN 61000-4-11:2004 Voltage dips & interruptions EMC Emissions EN 55014-1:2001 Household appliances EN 55022 Class B:1998 Domestic environments Approvals UL Recognised FCC Compliant CE Mark Standards UL 508 CSA C22.2 No. 14-05 25.3 Max electronics PCB 0.8Sq 94 All dimensions in millimetres (mm) tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 95 APPLICATIONS INDICATIONS ៉ Limit switch detection and display – machine position ៉ Differential air pressure sensing - filter status indicator ៉ Latching and display of momentary sensor signals The smart indicator operates like a standard neon indicator, giving visible status indication for the application. Normal operation shows a continuous Green LED illumination (contact sales for other colours) while an error or fault condition results in a RED illumination. Fault condition indication can be factory configured as flashing. Status indicators are commonly used on equipment and machinery to advise the operator that particular device conditions are normal, operational status is active or inactive, equipment is on-line or off-line. Various standard switches and sensors can be used to determine position, location, rotation speed, airflow, air pressure, vacuum level, interlock etc. The indicators’ sensing input provides a non-isolated DC voltage, current limited to 1mA, for detection of volt-free normally open or normally closed switch contacts, or open-collector type sensors. Some switches can exhibit transient effects or require de-bounce functions, most of which can be masked by having a qualifying time period before the indication takes place. In some applications a hold-off delay could be useful to ignore any settling during initial operation, or indications may only be required after power-up and then latched. The indicator can be factory programmed to cater for many different requirements, please contact us with application details. PART NUMBER CONNECTIONS Live 1 Specify Terminal Type: Specify Model Code: Specify Supply Voltage: Sensor/Switch Contact 2 3 4 1437AL Neutral Specify LED Colour: Specify application requirements: C, H, T, X 1437AL 230Vac, 115Vac, 48Vdc, 48Vac, 24Vdc, 24Vac, 12Vdc, 12Vac Green/Red, Blue/Red Normally open/closed contact, time delay, latching etc. electronics tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk 95 CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:55 Page 96 Single phase mains supply checker 1430 Smart indicator series ៉ Monitors appliance and mains supply 230V 50Hz. 115Vac 60Hz available. Less than 1 watt (power consumption) ៉ Direct replacement for Neon indicator ៉ Equipment safety indication UL Recognised. File no. E311309 ៉ Checks for swapped connections ៉ Checks for missing connections CE Mark ៉ Green LED indicates normal operation ៉ Steady Red LED indicates connection ៉ ៉ ៉ ៉ ៉ fault Flashing Red LED indicates missing connection Live, Neutral and Earth connections Convenient snap-in design Fast-on terminals Panel cut out: 30.0 x 11.0 FCC compliant RoHS RoHS compliant C 1431 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY TERMINAL BODY & DIMENSIONS L Panel Cut-Out C H SPECIFICATION Dimensions 30.0 30.1 6.3 x 0.8 11.0/11.1 Bezel 4.8 x 0.8 VOLTAGE, COLOUR R1.0 Panel thickness Bezel 32.0mm x 14.0mm Panel cut-out 11.0/11.1mm x 30.0/30.1mm 0.75mm to 2.5mm Body Lens Terminals Flame retardancy RoHS compliant Nylon 6.6, matt finish, black colour is standard Clear Polycarbonate, Softline matt finish Copper alloy, Silver plated UL94V0 Yes Operating supply Power consumption 230V ±20% 50Hz. 115V 60Hz available Less than 1 Watt Operating conditions (body) -20°C to +70°C (-4°F to 158°F) 0 to 95% RH (non-condensing) Electromagnetic Compatibility Compliant with directives 89/336/EEC & 92/31/EEC EMC Immunity EN 55014-2:1997 Household appliances EN 61000-6-2:2005 Industrial Environments,10 V/m EN 61000-4-2:1995 Electrostatic Discharges (ESD) EN 61000-4-3:2002 RF Electromagnetic fields EN 61000-4-4:2004 Fast Transients & Bursts EN 61000-4-5:1995 Surges EN 61000-4-6:1996 Conducted disturbances EN 61000-4-11:2004 Voltage dips & interruptions EMC Emissions EN 55014-1:2001 Household appliances EN 55022 Class B:1998 Domestic environments Approvals UL Recognised FCC Compliant CE Mark Standards UL 508 CSA C22.2 No. 14-05 32.0 T 14.0 Ø2.1 Dimensions Solder 2.0 25.3 Max X 4.0 electronics PCB 0.8Sq 96 All dimensions in millimetres (mm) tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:56 Page 97 APPLICATIONS INDICATIONS The smart indicator can detect and display the following fault conditions: ៉ Portable appliances ៉ Site equipment Terminal 1 Terminal4 Terminal 3 ៉ Commercial kitchens L N E Normal Green ៉ Stainless steel appliances N L E L/N Swapped Red E N L L/E Swapped Red ៉ Extension cables/reels E L N Wrong sequence Red ៉ Garden equipment N E L Wrong sequence Red L - E Neutral missing Flashing Red L N - Earth missing Flashing Red ៉ Power tools ៉ Audio equipment ៉ Consumer units CONNECTIONS Fault LED Indication PART NUMBER 1 Live 3 Earth 4 1431AL Neutral Specify Terminal Type: Specify Model Code: Specify Supply Voltage: Specify LED Colour: C, H, T, X 1431AL 115Vac, 230Vac Green/Red, Blue/Red electronics tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk 97 CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:56 Page 98 Temperature Micro Logger 1430 Smart indicator series ៉ Intelligent temperature logger for 100 to 230Vac ±20% 50/60Hz. Less than 1 watt (power consumption) refrigeration ៉ Wireless data communication ៉ Over 14,000 data readings stored UL Recognised. File no. E311309 ៉ Non-volatile memory CE Mark ៉ Industry standard Thermistor supplied ៉ Configurable data log interval FCC compliant ៉ Monitors mains power interruptions ៉ Programmable upper/lower limit alarm ៉ Blue LED indicates normal operation RoHS RoHS compliant ៉ Red LED indicates problem ៉ Snap-in mounting ៉ Panel cut out: 30.0 x 11.0 C 1435 A L - - TERMINAL FUNCTION SOFTLINE LENS BODY COLOUR TERMINAL BODY & DIMENSIONS L Panel Cut-Out C Dimensions 30.0 30.1 6.3 x 0.8 H 11.0/11.1 Bezel 4.8 x 0.8 T R1.0 Dimensions Solder 66 X 4.0 Panel thickness Bezel 32.0mm x 14.0mm Panel cut-out 11.0/11.1mm x 30.0/30.1mm 0.75mm to 2.5mm Body Lens Terminals Flame retardancy RoHS compliant Nylon 6.6, matt finish, black colour is standard Clear Polycarbonate, Softline matt finish Copper alloy, Silver plated UL94V-0 Yes Operating supply Power consumption 100 to 230Vac ±20% 50/60Hz. Less than 1 Watt Operating conditions (body) –20°C to +70°C (–4°F to 158°F) 0 to 95% RH (non-condensing) Measurement range Measurement accuracy Measurement resolution Temperature sensor –30ºC to +80ºC (–22ºF to +176ºF) ±1.0ºC (±1.8F) ±0.5ºC (±0.9ºF) NTC Thermistor, sealed sensor, cable length 1m Communications method Logging Interval Logging data capacity Data retention Infrared serial data port Programmable 1 second to 12 hours per reading >14,000 measurements stored >10 years without power Electromagnetic Compatibility Compliant with directives 89/336/EEC & 92/31/EEC EMC Immunity EN 55014-2:1997 Household appliances EN 61000-6-2:2005 Industrial Environments,10 V/m EN 61000-4-2:1995 Electrostatic Discharges (ESD) EN 61000-4-3:2002 RF Electromagnetic fields EN 61000-4-4:2004 Fast Transients & Bursts EN 61000-4-5:1995 Surges EN 61000-4-6:1996 Conducted disturbances EN 61000-4-11:2004 Voltage dips & interruptions EMC Emissions EN 55014-1:2001 Household appliances EN 55022 Class B:1998 Domestic environments Approvals UL Recognised FCC compliant CE Mark Standards UL 508 CSA C22.2 No. 14-05 32.0 14.0 Ø2.1 SPECIFICATION electronics PCB 0.8Sq 98 All dimensions in millimetres (mm) tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk CAT 170 P90-99 Smart Inds_2:CAT 170 P90-105 Smart Inds 19/11/09 13:56 Page 99 APPLICATIONS INDICATIONS An Intelligent temperature data logging device for refrigeration applications, ideal for monitoring that freezers and chillers are maintaining the required temperatures to comply with food safety guidelines. ៉ Refrigeration temperature monitoring for food safety compliance ៉ Deep freeze monitoring ៉ Cold storage monitor Designed to directly replace the standard neon indicator already fitted on many appliances, the front-panel mounted temperature logger operates like a standard neon indicator, giving visible status indication for the appliance or application. Normal operation will show continuous blue LED illumination (contact sales for other colours) while the monitored temperature is within the ‘safe’ range between lower and upper limits. The upper and lower temperature limits for alarm indication are fully user programmable. ៉ Chiller monitoring ៉ Process control temperature monitoring ៉ Visual checking of correct temperature ៉ Control system verification – independent monitoring of controller ៉ Power quality indication – records power interruptions ៉ Equipment status check - simple indicator lights The embedded microcontroller stores the temperature readings at regular intervals for retrieval and analysis. Over 14,000 readings can be stored in non-volatile memory (no battery is required). The data log interval is user configurable between 1 second and 12 hours. The logger also records the number of mains power interruptions. Stored data can be transferred to a collection device (PDA or Laptop) via a wireless infrared data link, a serial to infared communication adapter is available as an accessory. The device is provided with an industry standard Thermistor temperature sensor. PC and PDA software can be downloaded from www.arcolectric.co.uk/software CONNECTIONS PART NUMBERS 1435AL Specify Terminal Type: Specify Model Code: Specify LED Colour: 3 4 Live C, H, T, X 1435AL Green/Red, Blue/Red 2 Thermistor 1 Neutral SOFTWARE The PC software allows fast and simple configuration of the temperature micro logger device settings. The stored temperature data can be easily extracted using a serial port infrared data link. With a single button press, the ‘Download log’ feature imports the stored temperature reading data directly into an Excel spreadsheet for easy analysis and display. The logging time interval can be set to suit the end application. Low and high alarm setpoints can be fully configured for LED indication on the logger front panel. When the measured temperature is between the low and high limits, the Blue LED illuminates to indicate that the measured temperature is acceptable. When the measured temperature falls outside of low or high alarm setpoint, the LED illumination changes colour to Red. Additionally, if the alarm memory box is checked, the only way to clear a temperature alarm is to press the ‘Alarm Clear’ button. The Logger status is continually updated while the infrared data link is active, and the current measured temperature is displayed in °C or °F. electronics Memory usage can also be monitored. tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk 99
C1435ALMAA 价格&库存

很抱歉,暂时无法提供与“C1435ALMAA”相匹配的价格&库存,您可以联系我们找货

免费人工找货