74AC11008
QUADRUPLE 2-INPUT POSITIVE-AND GATE
SCAS014C – AUGUST 1987 – REVISED APRIL 1996
D
D
D
D
D
D, N, OR PW PACKAGE
(TOP VIEW)
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPIC (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity at
125°C
Package Options Include Plastic
Small-Outline (D) and Thin Shrink
Small-Outline (PW) Packages, and
Standard Plastic 300-mil DIPs (N)
1A
1Y
2Y
GND
GND
3Y
4Y
4B
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
1B
2A
2B
VCC
VCC
3A
3B
4A
description
This device contains four independent 2-input AND gates. It performs the Boolean function
Y
+ A • B or Y + A ) B in positive logic.
The 74AC11008 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
(each gate)
INPUTS
A
B
OUTPUT
Y
H
H
H
L
X
L
X
L
L
logic symbol†
1A
1B
2A
2B
3A
3B
4A
4B
1
&
16
2
1Y
15
3
14
2Y
11
6
10
3Y
9
7
8
4Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright 1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
74AC11008
QUADRUPLE 2-INPUT POSITIVE-AND GATE
SCAS014C – AUGUST 1987 – REVISED APRIL 1996
logic diagram (positive logic)
1A
1B
2A
2B
3A
3B
4A
4B
1
16
15
14
11
10
9
8
2
3
6
7
1Y
2Y
3Y
4Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . . . 1.3 W
N package . . . . . . . . . . . . . . . . . . . . 1.1 W
PW package . . . . . . . . . . . . . . . . . . . 0.5 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
74AC11008
QUADRUPLE 2-INPUT POSITIVE-AND GATE
SCAS014C – AUGUST 1987 – REVISED APRIL 1996
recommended operating conditions
VCC
Supply voltage
VIH
High-level input voltage
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
VCC = 3 V
MIN
NOM
MAX
3
5
5.5
0.9
VI
VO
Input voltage
0
Output voltage
0
IOH
High-level output current
∆t/∆v
Input transition rise or fall rate
TA
Operating free-air temperature
V
3.85
Low-level input voltage
Low-level output current
V
2.1
3.15
VIL
IOL
UNIT
VCC = 4.5 V
VCC = 5.5 V
1.35
V
1.65
VCC
VCC
VCC = 3 V
VCC = 4.5 V
V
V
–4
–24
VCC = 5.5 V
VCC = 3 V
–24
VCC = 4.5 V
VCC = 5.5 V
24
mA
12
mA
24
0
10
ns/V
–40
85
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
IOH = –50 µA
VOH
3V
2.9
2.9
4.5 V
4.4
4.4
5.4
5.4
3V
2.58
2.48
4.5 V
3.94
3.8
IOH = –24
24 mA
A
5.5 V
4.94
IOH = –75 mA†
5.5 V
IOL = 12 mA
IOL = 24 mA
II
ICC
MIN
5.5 V
IOH = –4 mA
IOL = 50 µA
VOL
TA = 25°C
MIN
TYP
MAX
MAX
UNIT
V
4.8
3.85
3V
0.1
0.1
4.5 V
0.1
0.1
5.5 V
0.1
0.1
3V
0.36
0.44
4.5 V
0.36
0.44
5.5 V
0.36
0.44
V
IOL = 75 mA†
5.5 V
VI = VCC or GND
VI = VCC or GND,
5.5 V
±0.1
±1
µA
5.5 V
4
40
µA
IO = 0
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1.65
pF
3
74AC11008
QUADRUPLE 2-INPUT POSITIVE-AND GATE
SCAS014C – AUGUST 1987 – REVISED APRIL 1996
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
MIN
TA = 25°C
TYP
MAX
MIN
MAX
1.5
6.3
9
1.5
10.2
1.5
5.6
7.8
1.5
8.6
UNIT
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
MIN
TA = 25°C
TYP
MAX
MIN
MAX
1.5
4.3
6.2
1.5
6.9
1.5
5.6
5.9
1.5
6.5
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
TEST CONDITIONS
Power dissipation capacitance per gate
CL = 50 pF,
TYP
f = 1 MHz
29
UNIT
pF
PARAMETER MEASUREMENT INFORMATION
Input
(see Note B)
From Output
Under Test
CL = 50 pF
(see Note A)
VCC
50% VCC
50% VCC
0V
tPLH
tPHL
500 Ω
Output
50% VCC
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
10-Dec-2020
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
74AC11008D
ACTIVE
SOIC
D
16
40
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
AC11008
74AC11008N
ACTIVE
PDIP
N
16
25
RoHS & Green
NIPDAU
N / A for Pkg Type
-40 to 85
74AC11008N
74AC11008PWR
ACTIVE
TSSOP
PW
16
2000
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
AE008
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
很抱歉,暂时无法提供与“74AC11008D”相匹配的价格&库存,您可以联系我们找货
免费人工找货