74ACT11032
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCAS008C – JULY 1987 – REVISED APRIL 1996
D
D
D
D
D
D, DB, N, OR PW PACKAGE
(TOP VIEW)
Inputs Are TTL-Voltage Compatible
Center-Pin VCC and GND Configurations to
Minimize High-Speed Switching Noise
EPICt (Enhanced-Performance Implanted
CMOS) 1-mm Process
500-mA Typical Latch-Up Immunity at 125°C
Package Options Include Plastic
Small-Outline Packages (D), Plastic Shrink
Small-Outline Packages (DB), Plastic Thin
Shrink Small-Outline Packages (PW), and
Standard Plastic 300-mil DIPs (N)
1A
1Y
2Y
GND
GND
3Y
4Y
4B
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
1B
2A
2B
VCC
VCC
3A
3B
4A
description
This device contains four independent 2-input OR gates. It performs the Boolean function Y = A + B or
Y
+ A • B in positive logic.
The 74ACT11032 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
(each gate)
B
OUTPUT
Y
H
X
H
X
H
H
L
L
L
INPUTS
A
logic symbol†
1A
1B
2A
2B
3A
3B
4A
4B
1
logic diagram (positive logic)
≥
16
2
1A
1Y
15
14
3
2A
2Y
1Y
1B
2Y
2B
11
10
6
3Y
3A
3Y
3B
9
7
8
4Y
4A
4B
4Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright 1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
74ACT11032
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCAS008C – JULY 1987 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 6V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . . . 1.3 W
DB package . . . . . . . . . . . . . . . . . . 0.55 W
N package . . . . . . . . . . . . . . . . . . . . 1.1 W
PW package . . . . . . . . . . . . . . . . . . . 0.5 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
recommended operating conditions
MIN
MAX
4.5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level input voltage
2
UNIT
V
V
0.8
V
VCC
VCC
V
High-level output current
– 24
mA
IOL
Dt /Dv
Low-level output current
24
mA
0
10
ns/ V
TA
Operating free-air temperature
–40
85
°C
2
Input transition rise or fall rate
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
74ACT11032
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCAS008C – JULY 1987 – REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
4.5 V
IOH = –50
50 mA
VOH
24 mA
IOH = –24
IOH = –75 mA†
DICC‡
MIN
4.4
4.4
5.5 V
5.4
5.4
4.5 V
3.94
3.8
5.5 V
4.94
MAX
UNIT
V
4.8
3.85
4.5 V
IOL = 24 mA
II
ICC
TA = 25°C
TYP
MAX
5.5 V
IOL = 50 mA
VOL
MIN
0.1
0.1
5.5 V
0.1
0.1
4.5 V
0.36
0.44
5.5 V
0.36
0.44
V
IOL = 75 mA†
VI = VCC or GND
5.5 V
5.5 V
±0.1
±1
mA
VI = VCC or GND,
IO = 0
One input at 3.4 V,
Other inputs at GND or VCC
5.5 V
4
40
mA
5.5 V
0.9
1
mA
1.65
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
pF
switching characteristics over recommended ranges of supply voltage and free-air temperature
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
MIN
TA = 25°C
TYP
MAX
MIN
MAX
1.5
6.2
8.1
1.5
9
1.5
4.9
7.4
1.5
8
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
TEST CONDITIONS
Power dissipation capacitance per gate
POST OFFICE BOX 655303
CL = 50 pF,
• DALLAS, TEXAS 75265
f = 1 MHz
TYP
UNIT
29
pF
3
74ACT11032
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCAS008C – JULY 1987 – REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
Input
(see Note B)
From Output
Under Test
CL = 50 pF
(see Note A)
3V
1.5 V
1.5 V
0V
tPLH
tPHL
500 Ω
Output
50% VCC
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns,
tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
14-Oct-2022
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
Samples
(4/5)
(6)
74ACT11032D
ACTIVE
SOIC
D
16
40
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
ACT11032
Samples
74ACT11032DR
ACTIVE
SOIC
D
16
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
ACT11032
Samples
74ACT11032N
ACTIVE
PDIP
N
16
25
RoHS & Green
NIPDAU
N / A for Pkg Type
-40 to 85
74ACT11032N
Samples
74ACT11032NE4
ACTIVE
PDIP
N
16
25
RoHS & Green
NIPDAU
N / A for Pkg Type
-40 to 85
74ACT11032N
Samples
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
很抱歉,暂时无法提供与“74ACT11032PWE4”相匹配的价格&库存,您可以联系我们找货