0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ADS1115BQDGSRQ1

ADS1115BQDGSRQ1

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TFSOP10

  • 描述:

    ADS1115-Q1 AUTOMOTIVE 16-BIT 860

  • 数据手册
  • 价格&库存
ADS1115BQDGSRQ1 数据手册
Order Now Product Folder Support & Community Tools & Software Technical Documents ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 ADS111x Ultra-Small, Low-Power, I2C-Compatible, 860-SPS, 16-Bit ADCs With Internal Reference, Oscillator, and Programmable Comparator 1 Features 3 Description • The ADS1113, ADS1114, and ADS1115 devices (ADS111x) are precision, low-power, 16-bit, I2Ccompatible, analog-to-digital converters (ADCs) offered in an ultra-small, leadless, X2QFN-10 package, and a VSSOP-10 package. The ADS111x devices incorporate a low-drift voltage reference and an oscillator. The ADS1114 and ADS1115 also incorporate a programmable gain amplifier (PGA) and a digital comparator. These features, along with a wide operating supply range, make the ADS111x well suited for power- and space-constrained, sensor measurement applications. 1 • • • • • • • • • • Ultra-Small X2QFN Package: 2 mm × 1.5 mm × 0.4 mm Wide Supply Range: 2.0 V to 5.5 V Low Current Consumption: 150 μA (Continuous-Conversion Mode) Programmable Data Rate: 8 SPS to 860 SPS Single-Cycle Settling Internal Low-Drift Voltage Reference Internal Oscillator I2C Interface: Four Pin-Selectable Addresses Four Single-Ended or Two Differential Inputs (ADS1115) Programmable Comparator (ADS1114 and ADS1115) Operating Temperature Range: –40°C to +125°C The ADS111x perform conversions at data rates up to 860 samples per second (SPS). The PGA offers input ranges from ±256 mV to ±6.144 V, allowing precise large- and small-signal measurements. The ADS1115 features an input multiplexer (MUX) that allows two differential or four single-ended input measurements. Use the digital comparator in the ADS1114 and ADS1115 for under- and overvoltage detection. 2 Applications • • • • • The ADS111x operate in either continuousconversion mode or single-shot mode. The devices are automatically powered down after one conversion in single-shot mode; therefore, power consumption is significantly reduced during idle periods. Portable Instrumentation Battery Voltage and Current Monitoring Temperature Measurement Systems Consumer Electronics Factory Automation and Process Control Device Information(1) PART NUMBER ADS111x PACKAGE BODY SIZE (NOM) X2QFN (10) 1.50 mm × 2.00 mm VSSOP (10) 3.00 mm × 3.00 mm (1) For all available packages, see the package option addendum at the end of the data sheet. Simplified Block Diagrams VDD VDD VDD Comparator Voltage Reference AIN0 AIN1 16-Bit û¯ ADC ADDR I2C Interface SDA Oscillator AIN0 PGA SCL AIN1 16-Bit û¯ ADC ADDR I2C Interface GND SCL SDA AIN0 AIN1 AIN2 AIN3 MUX PGA 16-Bit û¯ ADC ADS1114 GND ALERT/ RDY Voltage Reference ADDR I2C Interface SCL SDA Oscillator Oscillator ADS1113 Comparator ALERT/ RDY Voltage Reference ADS1115 GND Copyright © 2016, Texas Instruments Incorporated 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Table of Contents 1 2 3 4 5 6 7 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Device Comparison Table..................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 2 5 5 6 7.1 7.2 7.3 7.4 7.5 7.6 7.7 6 6 6 6 7 8 9 Absolute Maximum Ratings ...................................... ESD Ratings.............................................................. Recommended Operating Conditions....................... Thermal Information .................................................. Electrical Characteristics.......................................... Timing Requirements: I2C......................................... Typical Characteristics .............................................. 8 Parameter Measurement Information ................ 13 9 Detailed Description ............................................ 14 8.1 Noise Performance ................................................. 13 9.1 9.2 9.3 9.4 Overview ................................................................. Functional Block Diagrams ..................................... Feature Description................................................. Device Functional Modes........................................ 14 14 15 21 9.5 Programming........................................................... 22 9.6 Register Map........................................................... 27 10 Application and Implementation........................ 31 10.1 Application Information.......................................... 31 10.2 Typical Application ............................................... 36 11 Power Supply Recommendations ..................... 40 11.1 Power-Supply Sequencing.................................... 40 11.2 Power-Supply Decoupling..................................... 40 12 Layout................................................................... 41 12.1 Layout Guidelines ................................................. 41 12.2 Layout Example .................................................... 42 13 Device and Documentation Support ................. 43 13.1 13.2 13.3 13.4 13.5 13.6 13.7 Documentation Support ........................................ Related Links ........................................................ Receiving Notification of Documentation Updates Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 43 43 43 43 43 43 43 14 Mechanical, Packaging, and Orderable Information ........................................................... 44 4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision C (December 2016) to Revision D Page • Changed Digital input voltage max value from VDD + 0.3 V to 5.5 V in Absolute Maximum Ratings table .......................... 6 • Added "over temperature" to Offset drift parameter for clarity ............................................................................................... 7 • Added Long-term Offset drift parameter in Electrical Characteristics table ........................................................................... 7 • Added "over temperature" to Gain drift parameter for clarity ................................................................................................. 7 • Added Long-term gain drift parameter in Electrical Characteristics table .............................................................................. 7 • Changed VIH parameter max value from VDD to 5.5 V in Electrical Characteristics table .................................................... 7 • Added Output Data Rate and Conversion Time section for clarity....................................................................................... 17 • Changed Figure 28, ALERT Pin Timing Diagram, for clarity................................................................................................ 19 • Changed Figure 39, Typical Connections of the ADS1115, for clarity ................................................................................. 31 • Changed the resistor values in Figure 43, Basic Hardware Configuration, from 10 Ω to 10 kΩ.......................................... 35 Changes from Revision B (October 2009) to Revision C Page • Added Device Information, ESD Ratings, Recommended Operating Conditions, and Thermal Information tables, and Parameter Measurement Information, Detailed Description, Application and Implementation, Power Supply Recommendations, Layout, Device and Documentation Support, and Mechanical, Packaging, and Orderable Information sections................................................................................................................................................................ 1 • Changed Title, and Description, Features, and Applications sections for clarity ................................................................... 1 • Deleted temperature range text from Description section and moved to Features section ................................................... 1 • Changed Product Family table title to Device Comparison Table and deleted Package Designator column........................ 5 • Changed Pin Functions table for clarity.................................................................................................................................. 5 • Changed Power-supply voltage max value from 5.5 V to 7 V in Absolute Maximum Ratings table...................................... 6 • Changed Analog input voltage min value from –0.3 V to GND – 0.3 V in Absolute Maximum Ratings table ....................... 6 2 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 • Changed Digital input voltage min value from –0.5 V to GND – 0.3 V in Absolute Maximum Ratings table......................... 6 • Changed Digital input voltage max value from 5.5 V to VDD + 0.3 V in Absolute Maximum Ratings table .......................... 6 • Deleted Analog input current rows in Absolute Maximum Ratings table................................................................................ 6 • Added Input current row in Absolute Maximum Ratings table ............................................................................................... 6 • Added Operating temperature range of –40°C to +125°C back into Absolute Maximum Ratings table................................ 6 • Added minimum specification of –40°C for TJ in Absolute Maximum Ratings table ............................................................. 6 • Changed Electrical Characteristics table conditions line for clarity ........................................................................................ 7 • Changed all instances of "FS" to "FSR" ................................................................................................................................. 7 • Deleted FSR from Electrical Characteristics and moved to Recommended Operating Conditions table .............................. 7 • Added values from Table 2 to Differential input impedance parameter in Electrical Characteristics table............................ 7 • Changed Output noise parameter link from "see Typical Characteristics" to "see Noise Performance section" in Electrical Characteristics table ............................................................................................................................................... 7 • Changed Offset error empty min value to –3, and max value from ±3 to 3 for clarity in Electrical Characteristics table ...... 7 • Changed VIH parameter max value from 5.5 V to VDD in Electrical Characteristics table .................................................... 7 • Changed VIL parameter min value from GND – 0.5 V to GND in Electrical Characteristics table ......................................... 7 • Changed Input leakage current parameters from two rows to one row, changed test conditions from VIH = 5.5V and VIL = GND to GND < VDIG < VDD, and changed min value from 10 µA to –10 µA in Electrical Characteristics table........... 7 • Changed text in note 1 of Electrical Characteristics table from "In no event should more than VDD + 0.3 V be applied to this device" to "No more than VDD + 0.3 V or 5.5 V (whichever is smaller) must be applied to this device. See Table 3 for more information."......................................................................................................................................... 7 • Deleted Power-supply voltage parameter from Electrical Characteristics and moved to Recommended Operating Conditions table ...................................................................................................................................................................... 8 • Deleted Specified temperature parameter from Electrical Characteristics and moved to Recommended Operating Conditions table ...................................................................................................................................................................... 8 • Deleted Storage temperature parameter from Electrical Characteristics and moved to Absolute Maximum Ratings table .. 8 • Added condition statement in Timing Requirements: I2C table .............................................................................................. 8 • Added note 1 to Timing Requirements table .......................................................................................................................... 8 • Changed Figure 22; deleted "Gain = 2/3, 1, 2, 4, 8, or 16" ................................................................................................. 14 • Added Functional Block Diagrams for ADS1114 and ADS1113 .......................................................................................... 14 • Changed Analog Inputs section to provide LSB size information instead of PGA setting ................................................... 16 • Changed Full-Scale Input section title to Full-Scale Range (FSR) and LSB Size, and updated section for clarity ............. 17 • Added Voltage Reference and Oscillator sections ............................................................................................................... 17 • Changed Comparator section title to Digital Comparator, and updated section for clarity. ................................................. 17 • Changed Conversion Ready Pin section for clarity .............................................................................................................. 19 • Changed Register Map section for clarity ............................................................................................................................ 27 • Changed Application Information section for clarity ............................................................................................................. 31 • Added Input Protection section............................................................................................................................................. 32 • Added Unused Inputs and Outputs section.......................................................................................................................... 32 • Changed Aliasing section title to Analog Input Filtering and updated section for clarity...................................................... 33 • Added Typical Application section........................................................................................................................................ 36 Changes from Revision A (August 2009) to Revision B Page • Deleted Operating Temperature bullet from Features section ............................................................................................... 1 • Deleted Operating temperature range from Absolute Maximum Ratings table...................................................................... 6 • Deleted Operating temperature parameter from Temperature section of Electrical Characteristics table............................. 8 • Changed Figure 2, Operating Current vs Temperature, to reflect maximum operating temperature .................................... 9 • Changed Figure 3, Power-Down Current vs Temperature, to reflect maximum operating temperature................................ 9 Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 3 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com • Changed Figure 4, Single-Ended Offset Error vs Temperature, to reflect maximum operating temperature ........................ 9 • Changed Figure 5, Differential Offset vs Temperature, to reflect maximum operating temperature ..................................... 9 • Changed Figure 6, Gain Error vs Temperature, to reflect maximum operating temperature................................................. 9 • Changed 140°C to 125°C in Figure 9, INL vs Input Signal .................................................................................................... 9 • Changed +140°C to +125°C in Figure 10, INL vs Input Signal .............................................................................................. 9 • Changed +140°C to +125°C in Figure 11, INL vs Input Signal .............................................................................................. 9 • Changed +140°C to +125°C in Figure 12, INL vs Input Signal .............................................................................................. 9 • Changed Figure 13, INL vs Temperature, to reflect maximum operating temperature.......................................................... 9 • Changed Figure 16, Noise vs Temperature, to reflect maximum operating temperature .................................................... 10 • Changed Figure 20, Data Rate vs Temperature, to reflect maximum operating temperature ............................................. 11 4 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 5 Device Comparison Table DEVICE RESOLUTION (Bits) MAXIMUM SAMPLE RATE (SPS) INPUT CHANNELS Differential (Single-Ended) PGA INTERFACE SPECIAL FEATURES ADS1115 16 860 2 (4) Yes I2C Comparator ADS1114 16 860 1 (1) Yes I2C Comparator ADS1113 16 860 1(1) No I2C ADS1015 12 3300 2 (4) Yes IC Comparator ADS1014 12 3300 1 (1) Yes I2C Comparator ADS1013 12 3300 1 (1) No I2C None ADS1118 16 860 2 (4) Yes SPI Temperature sensor ADS1018 12 3300 2 (4) Yes SPI Temperature sensor None 2 6 Pin Configuration and Functions RUG Package 10-Pin X2QFN Top View SCL DGS Package 10-Pin VSSOP Top View ADDR 1 10 SCL ALERT/RDY 2 9 SDA GND 3 8 VDD AIN0 4 7 AIN3 AIN1 5 6 AIN2 10 ADDR 1 9 SDA ALERT/RDY 2 8 VDD 3 7 AIN3 AIN0 4 6 AIN2 Not to scale AIN1 5 GND Not to scale Pin Functions PIN (1) NAME ADS1113 ADS1114 ADS1115 TYPE DESCRIPTION 2 ADDR 1 1 1 Digital input I C slave address select AIN0 4 4 4 Analog input Analog input 0 AIN1 5 5 5 Analog input Analog input 1 AIN2 — — 6 Analog input Analog input 2 (ADS1115 only) AIN3 — — 7 Analog input Analog input 3 (ADS1115 only) ALERT/RDY — 2 2 Digital output Comparator output or conversion ready (ADS1114 and ADS1115 only) GND 3 3 3 Analog NC 2, 6, 7 6, 7 — — SCL 10 10 10 Digital input SDA 9 9 9 Digital I/O VDD 8 8 8 Analog (1) Ground Not connected Serial clock input. locks data on SDA Serial data. Transmits and receives data Power supply. Connect a 0.1-μF, power-supply decoupling capacitor to GND. See the Unused Inputs and Outputs section for unused pin connections. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 5 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 7 Specifications 7.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted) (1) MIN MAX UNIT –0.3 7 V AIN0, AIN1, AIN2, AIN3 GND – 0.3 VDD + 0.3 V SDA, SCL, ADDR, ALERT/RDY GND – 0.3 5.5 V Any pin except power supply pins –10 10 mA Operating ambient, TA –40 125 Junction, TJ –40 150 Storage, Tstg –60 150 Power-supply voltage VDD to GND Analog input voltage Digital input voltage Input current, continuous Temperature (1) °C Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 7.2 ESD Ratings VALUE V(ESD) (1) (2) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) ±2000 Charged-device model (CDM), per JEDEC specification JESD22-C101 (2) ±500 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. 7.3 Recommended Operating Conditions MIN NOM MAX UNIT POWER SUPPLY Power supply (VDD to GND) 2 5.5 V ±0.256 ±6.144 V GND VDD V GND 5.5 V –40 125 °C ANALOG INPUTS (1) FSR Full-scale input voltage range (2) (VIN = V(AINP) – V(AINN)) V(AINx) Absolute input voltage DIGITAL INPUTS VDIG Digital input voltage TEMPERATURE TA (1) (2) Operating ambient temperature AINP and AINN denote the selected positive and negative inputs. AINx denotes one of the four available analog inputs. This parameter expresses the full-scale range of the ADC scaling. No more than VDD + 0.3 V must be applied to the analog inputs of the device. See Table 3 more information. 7.4 Thermal Information ADS111x THERMAL METRIC (1) DGS (VSSOP) RUG (X2QFN) UNIT 10 PINS 10 PINS RθJA Junction-to-ambient thermal resistance 182.7 245.2 °C/W RθJC(top) Junction-to-case (top) thermal resistance 67.2 69.3 °C/W RθJB Junction-to-board thermal resistance 103.8 172.0 °C/W ψJT Junction-to-top characterization parameter 10.2 8.2 °C/W ψJB Junction-to-board characterization parameter 102.1 170.8 °C/W RθJC(bot) Junction-to-case (bottom) thermal resistance N/A N/A °C/W (1) 6 For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report. Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com 7.5 SBAS444D – MAY 2009 – REVISED JANUARY 2018 Electrical Characteristics At VDD = 3.3 V, data rate = 8 SPS, and full-scale input voltage range (FSR) = ±2.048 V (unless otherwise noted). Maximum and minimum specifications apply from TA = –40°C to +125°C. Typical specifications are at TA = 25°C. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ANALOG INPUT FSR = ±6.144 V (1) Common-mode input impedance 10 FSR = ±4.096 V (1), FSR = ±2.048 V 6 FSR = ±1.024 V 3 FSR = ±0.512 V, FSR = ±0.256 V FSR = ±6.144 V Differential input impedance MΩ 100 (1) 22 FSR = ±4.096 V (1) 15 FSR = ±2.048 V 4.9 FSR = ±1.024 V 2.4 FSR = ±0.512 V, ±0.256 V 710 MΩ kΩ SYSTEM PERFORMANCE Resolution (no missing codes) DR 16 Data rate Data rate variation All data rates Output noise INL –10% 10% DR = 8 SPS, FSR = ±2.048 V (2) FSR = ±2.048 V, differential inputs Offset error 1 –3 FSR = ±2.048 V, single-ended inputs Offset drift over temperature FSR = ±2.048 V Long-term Offset drift FSR = ±2.048 V, TA = 125°C, 1000 hrs Offset power-supply rejection Offset channel match Gain error (3) FSR = ±2.048 V, TA = 25°C (3) ±1 LSB ±3 0.005 LSB/°C ±1 LSB FSR = ±2.048 V, DC supply variation 1 LSB/V Match between any two inputs 3 0.01% FSR = ±0.256 V 7 FSR = ±2.048 V 5 FSR = ±6.144 V (1) 5 LSB 0.15% 40 ±0.05 Gain match (3) Match between any two gains 0.02% 0.1% Gain channel match Match between any two inputs 0.05% 0.1% Gain power-supply rejection Common-mode rejection ratio LSB 3 FSR = ±2.048 V, TA = 125°C, 1000 hrs Long-term gain drift (3) CMRR SPS See Noise Performance section Integral nonlinearity Gain drift over temperature Bits 8, 16, 32, 64, 128, 250, 475, 860 % 80 At DC, FSR = ±0.256 V 105 At DC, FSR = ±2.048 V 100 At DC, FSR = ±6.144 V (1) 90 fCM = 60 Hz, DR = 8 SPS 105 fCM = 50 Hz, DR = 8 SPS 105 ppm/°C ppm/V dB DIGITAL INPUT/OUTPUT VIH High-level input voltage 0.7 VDD 5.5 V VIL Low-level input voltage GND 0.3 VDD V VOL Low-level output voltage IOL = 3 mA Input leakage current GND < VDIG < VDD (1) (2) (3) GND –10 0.15 0.4 V 10 µA This parameter expresses the full-scale range of the ADC scaling. No more than VDD + 0.3 V must be applied to the analog inputs of the device. See Table 3 more information. Best-fit INL; covers 99% of full-scale. Includes all errors from onboard PGA and voltage reference. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 7 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Electrical Characteristics (continued) At VDD = 3.3 V, data rate = 8 SPS, and full-scale input voltage range (FSR) = ±2.048 V (unless otherwise noted). Maximum and minimum specifications apply from TA = –40°C to +125°C. Typical specifications are at TA = 25°C. PARAMETER TEST CONDITIONS MIN TYP MAX TA = 25°C 0.5 2 TA = 25°C 150 200 UNIT POWER-SUPPLY Power-down IVDD 5 Supply current Operating PD Power dissipation µA 300 VDD = 5.0 V 0.9 VDD = 3.3 V 0.5 VDD = 2.0 V 0.3 mW 7.6 Timing Requirements: I2C over operating ambient temperature range and VDD = 2.0 V to 5.5 V (unless otherwise noted) FAST MODE HIGH-SPEED MODE MIN MAX MIN MAX UNIT 0.4 0.01 3.4 MHz fSCL SCL clock frequency 0.01 tBUF Bus free time between START and STOP condition 600 160 ns tHDSTA Hold time after repeated START condition. After this period, the first clock is generated. 600 160 ns tSUSTA Setup time for a repeated START condition 600 160 ns tSUSTO Setup time for STOP condition 600 160 ns tHDDAT Data hold time tSUDAT Data setup time tLOW 0 0 ns 100 10 ns Low period of the SCL clock pin 1300 160 ns tHIGH High period for the SCL clock pin 600 tF Rise time for both SDA and SCL signals (1) 300 160 ns tR Fall time for both SDA and SCL signals (1) 300 160 ns (1) 60 ns For high-speed mode maximum values, the capacitive load on the bus line must not exceed 400 pF. t LOW tR tF t HDSTA SCL t HIGH t HDSTA t HDDAT SDA t SUSTO t SUSTA t SUDAT t BUF P S S P Figure 1. I2C Interface Timing 8 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 7.7 Typical Characteristics at TA = 25°C, VDD = 3.3 V, FSR = ±2.048 V, DR = 8 SPS (unless otherwise noted) 300 5.0 4.5 Power-down Current (µA) Operating Current (µA) 250 VDD = 5 V 200 150 VDD = 3.3 V VDD = 2 V 100 50 4.0 3.5 3.0 2.5 2.0 VDD = 5 V 1.5 VDD = 3.3 V 1.0 0.5 0 -40 -20 0 20 40 60 80 100 120 140 -40 -20 0 20 40 60 80 100 120 140 Temperature (°C) Temperature (°C) Figure 2. Operating Current vs Temperature Figure 3. Power-Down Current vs Temperature 150 60 FSR = ±4.096 V FSR = ±2.048 V 100 FSR = ±1.024 V FSR = ±0.512 V 50 VDD = 5 V 50 VDD = 2 V Offset Voltage (µV) Offset Error (µV) VDD = 2 V 0 0 -50 -100 -150 -200 VDD = 5 V 40 30 VDD = 4 V 20 VDD = 3 V 10 0 VDD = 2 V -10 -250 -20 -300 -40 -20 0 20 40 60 80 100 120 140 -40 -20 0 20 Temperature (°C) 40 60 80 100 120 140 Temperature (°C) Figure 4. Single-Ended Offset Error vs Temperature Figure 5. Differential Offset vs Temperature 0.05 0.15 FSR = ±0.256 V 0.04 0.10 FSR = ±0.512 V 0.02 Gain Error (%) Gain Error (%) 0.03 0.01 FSR = ±1.024 V, ±2.048 V, ±4.096 V, and ±6.144 V 0 -0.01 -0.02 0.05 FSR = ±256 mV 0 FSR = ±2.048 V -0.05 -0.10 -0.03 -0.15 -0.04 -40 -20 0 20 40 60 80 100 120 140 2.0 2.5 Figure 6. Gain Error vs Temperature 3.0 3.5 4.0 4.5 5.0 5.5 Supply Voltage (V) Temperature (°C) Figure 7. Gain Error vs Supply Voltage Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 9 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Typical Characteristics (continued) 60 60 50 40 Integral Nonlinearity (µV) Integral Nonlinearity (µV) at TA = 25°C, VDD = 3.3 V, FSR = ±2.048 V, DR = 8 SPS (unless otherwise noted) 40 FSR = ±6.144 V 30 FSR = ±2.048 V 20 FSR = ±0.512 V, ±0.256 V +125°C 20 -40°C 0 -20 +25°C -40 10 -60 0 2.0 2.5 3.0 3.5 4.0 4.5 5.0 -2.0 5.5 -1.5 -1.0 -0.5 0 0.5 1.0 1.5 2.0 Input Signal (V) Supply Voltage (V) VDD = 3.3 V, FSR = ±2.048 V, DR = 8 SPS, best fit Figure 8. INL vs Supply Voltage Figure 9. INL vs Input Signal 60 40 Integral Nonlinearity (µV) Integral Nonlinearity (µV) 60 +125°C 20 -40°C 0 +25°C -20 -40 40 20 TA = -40°C 0 -20 TA = +125°C TA = +25°C -40 -60 -60 -0.5 -0.375 -0.250 -0.125 0 0.125 0.250 0.375 0.5 -2.0 -1.5 -1.0 -0.5 Input Signal (V) VDD = 3.3 V, FSR = ±0.512 V, DR = 8 SPS, best fit Figure 10. INL vs Input Signal 1.5 2.0 Figure 11. INL vs Input Signal 120 Integral Nonlinearity (µV) Integral Nonlinearity (µV) 1.0 140 40 TA = +25°C TA = -40°C 0 -20 0.5 VDD = 5 V, FSR = ±2.048 V, DR = 8 SPS, best fit 60 20 0 Input Voltage (V) TA = +125°C 100 80 VDD = 2 V 60 VDD = 5 V 40 -40 20 -60 0 VDD = 3.3 V -0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 -60 -40 -20 Input Voltage (V) 0 20 40 60 80 100 120 140 Temperature (°C) VDD = 5 V, FSR = ±0.512 V, DR = 8 SPS, best fit Figure 12. INL vs Input Signal 10 Submit Documentation Feedback Figure 13. INL vs Temperature Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Typical Characteristics (continued) at TA = 25°C, VDD = 3.3 V, FSR = ±2.048 V, DR = 8 SPS (unless otherwise noted) 12 35 10 30 8 RMS Noise (µV) RMS Noise (µV) FSR = ±2.048 V DR = 860 SPS 6 DR = 128 SPS 4 DR = 8 SPS 20 15 128 SPS 10 2 5 0 0 -0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 860 SPS 25 8 SPS 2.0 0.5 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Supply Voltage (V) Input Voltage (V) FSR = ±0.512 V FSR = ±2.048 V Figure 14. Noise vs Input Signal Figure 15. Noise vs Supply Voltage 30 10 9 25 Number of Occurrences RMS Noise (µV) 8 7 6 5 4 3 2 20 15 10 5 1 0 -40 -20 0 20 40 60 80 100 120 -0.010 -0.005 0 0.005 0.010 0.015 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0 140 Temperature (°C) FSR = ±2.048 V, DR = 8 SPS Gain Error (%) FSR = ±2.048 V, 185 units Figure 17. Gain Error Histogram 4 140 3 120 2 Total Error (µV) Number of Occurrences Figure 16. Noise vs Temperature 160 100 80 60 1 0 -1 40 -2 20 -3 0 -3 -2 -1 0 1 2 3 -4 -2.048 -1.024 Offset (LSBs) FSR = ±2.048 V, 185 units Figure 18. Offset Histogram 0 1.024 2.048 Input Signal (V) Differential inputs; includes noise, offset and gain error Figure 19. Total Error vs Input Signal Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 11 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Typical Characteristics (continued) at TA = 25°C, VDD = 3.3 V, FSR = ±2.048 V, DR = 8 SPS (unless otherwise noted) 0 4 -10 VDD = 5 V -20 2 1 Gain (dB) Data Rate Error (%) 3 VDD = 3.3 V 0 -1 -30 -40 -50 -60 -2 VDD = 2 V -3 -70 -80 -4 -40 -20 0 20 40 60 80 100 120 140 1 10 100 1k 10k Input Frequency (Hz) Temperature (°C) DR = 8 SPS Figure 20. Data Rate vs Temperature 12 Submit Documentation Feedback Figure 21. Digital Filter Frequency Response Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 8 Parameter Measurement Information 8.1 Noise Performance Delta-sigma (ΔΣ) analog-to-digital converters (ADCs) are based on the principle of oversampling. The input signal of a ΔΣ ADC is sampled at a high frequency (modulator frequency) and subsequently filtered and decimated in the digital domain to yield a conversion result at the respective output data rate. The ratio between modulator frequency and output data rate is called oversampling ratio (OSR). By increasing the OSR, and thus reducing the output data rate, the noise performance of the ADC can be optimized. In other words, the inputreferred noise drops when reducing the output data rate because more samples of the internal modulator are averaged to yield one conversion result. Increasing the gain also reduces the input-referred noise, which is particularly useful when measuring low-level signals. Table 1 and Table 2 summarize the ADS111x noise performance. Data are representative of typical noise performance at TA = 25°C with the inputs shorted together externally. Table 1 shows the input-referred noise in units of μVRMS for the conditions shown. Note that µVPP values are shown in parenthesis. Table 2 shows the effective resolution calculated from μVRMS values using Equation 1. The noise-free resolution calculated from peak-to-peak noise values using Equation 2 are shown in parenthesis. Effective Resolution = ln (FSR / VRMS-Noise) / ln(2) Noise-Free Resolution = ln (FSR / VPP-Noise) / ln(2) (1) (2) Table 1. Noise in μVRMS (μVPP) at VDD = 3.3 V FSR (Full-Scale Range) DATA RATE (SPS) ±6.144 V ±4.096 V ±2.048 V ±1.024 V ±0.512 V ±0.256 V 8 187.5 (187.5) 125 (125) 62.5 (62.5) 31.25 (31.25) 15.62 (15.62) 7.81 (7.81) 16 187.5 (187.5) 125 (125) 62.5 (62.5) 31.25 (31.25) 15.62 (15.62) 7.81 (7.81) 32 187.5 (187.5) 125 (125) 62.5 (62.5) 31.25 (31.25) 15.62 (15.62) 7.81 (7.81) 64 187.5 (187.5) 125 (125) 62.5 (62.5) 31.25 (31.25) 15.62 (15.62) 7.81 (7.81) 128 187.5 (187.5) 125 (125) 62.5 (62.5) 31.25 (31.25) 15.62 (15.62) 7.81 (12.35) 250 187.5 (252.09) 125 (148.28) 62.5 (84.03) 31.25 (39.54) 15.62 (16.06) 7.81 (18.53) 475 187.5 (266.92) 125 (227.38) 62.5 (79.08) 31.25 (56.84) 15.62 (32.13) 7.81 (25.95) 860 187.5 (430.06) 125 (266.93) 62.5 (118.63) 31.25 (64.26) 15.62 (40.78) 7.81 (35.83) Table 2. Effective Resolution from RMS Noise (Noise-Free Resolution from Peak-to-Peak Noise) at VDD = 3.3 V FSR (Full-Scale Range) DATA RATE (SPS) ±6.144 V ±4.096 V ±2.048 V ±1.024 V ±0.512 V ±0.256 V 8 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 32 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 64 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 128 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.33) 250 16 (15.57) 16 (15.75) 16 (15.57) 16 (15.66) 16 (15.96) 16 (14.75) 475 16 (15.49) 16 (15.13) 16 (15.66) 16 (15.13) 16 (14.95) 16 (14.26) 860 16 (14.8) 16 (14.9) 16 (15.07) 16 (14.95) 16 (14.61) 16 (13.8) Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 13 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9 Detailed Description 9.1 Overview The ADS111x are very small, low-power, 16-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs). The ADS111x consist of a ΔΣ ADC core with an internal voltage reference, a clock oscillator and an I2C interface. The ADS1114 and ADS1115 also integrate a programmable gain amplifier (PGA) and a programmable digital comparator. Figure 22, Figure 23, and Figure 24 show the functional block diagrams of ADS1115, ADS1114, and ADS1113, respectively. The ADS111x ADC core measures a differential signal, VIN, that is the difference of V(AINP) and V(AINN). The converter core consists of a differential, switched-capacitor ΔΣ modulator followed by a digital filter. This architecture results in a very strong attenuation of any common-mode signals. Input signals are compared to the internal voltage reference. The digital filter receives a high-speed bitstream from the modulator and outputs a code proportional to the input voltage. The ADS111x have two available conversion modes: single-shot and continuous-conversion. In single-shot mode, the ADC performs one conversion of the input signal upon request, stores the conversion value to an internal conversion register, and then enters a power-down state. This mode is intended to provide significant power savings in systems that only require periodic conversions or when there are long idle periods between conversions. In continuous-conversion mode, the ADC automatically begins a conversion of the input signal as soon as the previous conversion is completed. The rate of continuous conversion is equal to the programmed data rate. Data can be read at any time and always reflect the most recent completed conversion. 9.2 Functional Block Diagrams VDD Comparator ADS1115 Voltage Reference MUX ALERT/RDY AIN0 ADDR AIN1 PGA 16-Bit û¯ ADC I2C Interface SCL SDA AIN2 Oscillator AIN3 GND Copyright © 2016, Texas Instruments Incorporated Figure 22. ADS1115 Block Diagram VDD VDD ADS1114 ADS1113 Comparator Voltage Reference ADDR AIN0 PGA AIN1 16-Bit û¯ ADC Voltage Reference ALERT/RDY I 2C Interface ADDR AIN0 SCL AIN1 16-Bit û¯ ADC SDA Oscillator GND Copyright © 2016, Texas Instruments Incorporated Figure 23. ADS1114 Block Diagram Submit Documentation Feedback SCL SDA Oscillator 14 I 2C Interface GND Copyright © 2016, Texas Instruments Incorporated Figure 24. ADS1113 Block Diagram Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 9.3 Feature Description 9.3.1 Multiplexer The ADS1115 contains an input multiplexer (MUX), as shown in Figure 25. Either four single-ended or two differential signals can be measured. Additionally, AIN0 and AIN1 may be measured differentially to AIN3. The multiplexer is configured by bits MUX[2:0] in the Config register. When single-ended signals are measured, the negative input of the ADC is internally connected to GND by a switch within the multiplexer. ADS1115 VDD AIN0 VDD GND AINP AINN AIN1 VDD GND AIN2 VDD GND AIN3 GND GND Copyright © 2016, Texas Instruments Incorporated Figure 25. Input Multiplexer The ADS1113 and ADS1114 do not have an input multiplexer and can measure either one differential signal or one single-ended signal. For single-ended measurements, connect the AIN1 pin to GND externally. In subsequent sections of this data sheet, AINP refers to AIN0 and AINN refers to AIN1 for the ADS1113 and ADS1114. Electrostatic discharge (ESD) diodes connected to VDD and GND protect the ADS111x analog inputs. Keep the absolute voltage of any input within the range shown in Equation 3 to prevent the ESD diodes from turning on. GND – 0.3 V < V(AINX) < VDD + 0.3 V (3) If the voltages on the input pins can potentially violate these conditions, use external Schottky diodes and series resistors to limit the input current to safe values (see the Absolute Maximum Ratings table). Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 15 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Feature Description (continued) 9.3.2 Analog Inputs The ADS111x use a switched-capacitor input stage where capacitors are continuously charged and then discharged to measure the voltage between AINP and AINN. The frequency at which the input signal is sampled is called the sampling frequency or the modulator frequency (fMOD). The ADS111x has a 1-MHz internal oscillator that is further divided by a factor of 4 to generate fMOD at 250 kHz. The capacitors used in this input stage are small, and to external circuitry, the average loading appears resistive. Figure 26 shows this structure. The capacitor values set the resistance and switching rate. Figure 27 shows the timing for the switches in Figure 26. During the sampling phase, switches S1 are closed. This event charges CA1 to V(AINP), CA2 to V(AINN), and CB to (V(AINP) – V(AINN)). During the discharge phase, S1 is first opened and then S2 is closed. Both CA1 and CA2 then discharge to approximately 0.7 V and CB discharges to 0 V. This charging draws a very small transient current from the source driving the ADS111x analog inputs. The average value of this current can be used to calculate the effective impedance (Zeff), where Zeff = VIN / IAVERAGE. 0.7 V CA1 AINP S1 S2 CB Equivalent Circuit 0.7 V ZCM AINP ZDIFF S2 S1 AINN 0.7 V AINN CA2 ZCM fMOD = 250 kHz 0.7 V Figure 26. Simplified Analog Input Circuit tSAMPLE ON S1 OFF ON S2 OFF Figure 27. S1 and S2 Switch Timing The common-mode input impedance is measured by applying a common-mode signal to the shorted AINP and AINN inputs and measuring the average current consumed by each pin. The common-mode input impedance changes depending on the full-scale range, but is approximately 6 MΩ for the default full-scale range. In Figure 26, the common-mode input impedance is ZCM. The differential input impedance is measured by applying a differential signal to AINP and AINN inputs where one input is held at 0.7 V. The current that flows through the pin connected to 0.7 V is the differential current and scales with the full-scale range. In Figure 26, the differential input impedance is ZDIFF. Make sure to consider the typical value of the input impedance. Unless the input source has a low impedance, the ADS111x input impedance may affect the measurement accuracy. For sources with high-output impedance, buffering may be necessary. Active buffers introduce noise, and also introduce offset and gain errors. Consider all of these factors in high-accuracy applications. The clock oscillator frequency drifts slightly with temperature; therefore, the input impedances also drift. For most applications, this input impedance drift is negligible, and can be ignored. 16 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Feature Description (continued) 9.3.3 Full-Scale Range (FSR) and LSB Size A programmable gain amplifier (PGA) is implemented before the ΔΣ ADC of the ADS1114 and ADS1115. The full-scale range is configured by bits PGA[2:0] in the Config register and can be set to ±6.144 V, ±4.096 V, ±2.048 V, ±1.024 V, ±0.512 V, ±0.256 V. Table 3 shows the FSR together with the corresponding LSB size. Equation 4 shows how to calculate the LSB size from the selected full-scale range. LSB = FSR / 216 (4) Table 3. Full-Scale Range and Corresponding LSB Size (1) FSR LSB SIZE ±6.144 V (1) 187.5 μV ±4.096 V (1) 125 μV ±2.048 V 62.5 μV ±1.024 V 31.25 μV ±0.512 V 15.625 μV ±0.256 V 7.8125 μV This parameter expresses the full-scale range of the ADC scaling. Do not apply more than VDD + 0.3 V to the analog inputs of the device. The FSR of the ADS1113 is fixed at ±2.048 V. Analog input voltages must never exceed the analog input voltage limits given in the Absolute Maximum Ratings. If a VDD supply voltage greater than 4 V is used, the ±6.144 V full-scale range allows input voltages to extend up to the supply. Although in this case (or whenever the supply voltage is less than the full-scale range; for example, VDD = 3.3 V and full-scale range = ±4.096 V), a full-scale ADC output code cannot be obtained. For example, with VDD = 3.3 V and FSR = ±4.096 V, only signals up to VIN = ±3.3 V can be measured. The code range that represents voltages |VIN| > 3.3 V is not used in this case. 9.3.4 Voltage Reference The ADS111x have an integrated voltage reference. An external reference cannot be used with these devices. Errors associated with the initial voltage reference accuracy and the reference drift with temperature are included in the gain error and gain drift specifications in the Electrical Characteristics table. 9.3.5 Oscillator The ADS111x have an integrated oscillator running at 1 MHz. No external clock can be applied to operate these devices. The internal oscillator drifts over temperature and time. The output data rate scales proportionally with the oscillator frequency. 9.3.6 Output Data Rate and Conversion Time The ADS111x offer programmable output data rates. Use the DR[2:0] bits in the Config register to select output data rates of 8 SPS, 16 SPS, 32 SPS, 64 SPS, 128 SPS, 250 SPS, 475 SPS, or 860 SPS. Conversions in the ADS111x settle within a single cycle; thus, the conversion time is equal to 1 / DR. 9.3.7 Digital Comparator (ADS1114 and ADS1115 Only) The ADS1115 and ADS1114 feature a programmable digital comparator that can issue an alert on the ALERT/RDY pin. The COMP_MODE bit in the Config register configures the comparator as either a traditional comparator or a window comparator. In traditional comparator mode, the ALERT/RDY pin asserts (active low by default) when conversion data exceeds the limit set in the high-threshold register (Hi_thresh). The comparator then deasserts only when the conversion data falls below the limit set in the low-threshold register (Lo_thresh). In window comparator mode, the ALERT/RDY pin asserts when the conversion data exceed the Hi_thresh register or fall below the Lo_thresh register value. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 17 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com In either window or traditional comparator mode, the comparator can be configured to latch after being asserted by the COMP_LAT bit in the Config register. This setting causes the assertion to remain even if the input signal is not beyond the bounds of the threshold registers. This latched assertion can only be cleared by issuing an SMBus alert response or by reading the Conversion register. The ALERT/RDY pin can be configured as active high or active low by the COMP_POL bit in the Config register. Operational diagrams for both the comparator modes are shown in Figure 28. The comparator can also be configured to activate the ALERT/RDY pin only after a set number of successive readings exceed the threshold values set in the threshold registers (Hi_thresh and Lo_thresh). The COMP_QUE[1:0] bits in the Config register configures the comparator to wait for one, two, or four readings beyond the threshold before activating the ALERT/RDY pin. The COMP_QUE[1:0] bits can also disable the comparator function, and put the ALERT/RDY pin into a high state. 18 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 9.3.8 Conversion Ready Pin (ADS1114 and ADS1115 Only) The ALERT/RDY pin can also be configured as a conversion ready pin. Set the most-significant bit of the Hi_thresh register to 1 and the most-significant bit of Lo_thresh register to 0 to enable the pin as a conversion ready pin. The COMP_POL bit continues to function as expected. Set the COMP_QUE[1:0] bits to any 2-bit value other than 11 to keep the ALERT/RDY pin enabled, and allow the conversion ready signal to appear at the ALERT/RDY pin output. The COMP_MODE and COMP_LAT bits no longer control any function. When configured as a conversion ready pin, ALERT/RDY continues to require a pullup resistor. The ADS111x provide an approximately 8-µs conversion ready pulse on the ALERT/RDY pin at the end of each conversion in continuous-conversion mode, as shown in Figure 29. In single-shot mode, the ALERT/RDY pin asserts low at the end of a conversion if the COMP_POL bit is set to 0. TH_H TH_H Input Signal Input Signal TH_L TH_L Time Time Successful SMBus Alert Response Latching Comparator Output Latching Comparator Output Successful SMBus Alert Response Successful SMBus Alert Response Time Time Non-Latching Comparator Output Non-Latching Comparator Output Time Time TRADITIONAL COMPARATOR MODE WINDOW COMPARATOR MODE Figure 28. ALERT Pin Timing Diagram ADS1114/5 Status Converting Converting Conversion Ready Converting Conversion Ready Converting Conversion Ready 8 µs ALERT/RDY (active high) Figure 29. Conversion Ready Pulse in Continuous-Conversion Mode Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 19 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.3.9 SMbus Alert Response In latching comparator mode (COMP_LAT = 1), the ALERT/RDY pin asserts when the comparator detects a conversion that exceeds the upper or lower threshold value. This assertion is latched and can be cleared only by reading conversion data, or by issuing a successful SMBus alert response and reading the asserting device I2C address. If conversion data exceed the upper or lower threshold values after being cleared, the pin reasserts. This assertion does not affect conversions that are already in progress. The ALERT/RDY pin is an open-drain output. This architecture allows several devices to share the same interface bus. When disabled, the pin holds a high state so that the pin does not interfere with other devices on the same bus line. When the master senses that the ALERT/RDY pin has latched, the master issues an SMBus alert command (00011001) to the I2C bus. Any ADS1114 and ADS1115 data converters on the I2C bus with the ALERT/RDY pins asserted respond to the command with the slave address. If more than one ADS111x on the I2C bus assert the latched ALERT/RDY pin, arbitration during the address response portion of the SMBus alert determines which device clears assertion. The device with the lowest I2C address always wins arbitration. If a device loses arbitration, the device does not clear the comparator output pin assertion. The master then repeats the SMBus alert response until all devices have the respective assertions cleared. In window comparator mode, the SMBus alert status bit indicates a 1 if signals exceed the high threshold, and a 0 if signals exceed the low threshold. 20 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 9.4 Device Functional Modes 9.4.1 Reset and Power-Up The ADS111x reset on power-up and set all the bits in the Config register to the respective default settings. The ADS111x enter a power-down state after completion of the reset process. The device interface and digital blocks are active, but no data conversions are performed. The initial power-down state of the ADS111x relieves systems with tight power-supply requirements from encountering a surge during power-up. The ADS111x respond to the I2C general-call reset commands. When the ADS111x receive a general call reset command (06h), an internal reset is performed as if the device is powered-up. 9.4.2 Operating Modes The ADS111x operate in one of two modes: continuous-conversion or single-shot. The MODE bit in the Config register selects the respective operating mode. 9.4.2.1 Single-Shot Mode When the MODE bit in the Config register is set to 1, the ADS111x enter a power-down state, and operate in single-shot mode. This power-down state is the default state for the ADS111x when power is first applied. Although powered down, the devices still respond to commands. The ADS111x remain in this power-down state until a 1 is written to the operational status (OS) bit in the Config register. When the OS bit is asserted, the device powers up in approximately 25 μs, resets the OS bit to 0, and starts a single conversion. When conversion data are ready for retrieval, the device powers down again. Writing a 1 to the OS bit while a conversion is ongoing has no effect. To switch to continuous-conversion mode, write a 0 to the MODE bit in the Config register. 9.4.2.2 Continuous-Conversion Mode In continuous-conversion mode (MODE bit set to 0), the ADS111x perform conversions continuously. When a conversion is complete, the ADS111x place the result in the Conversion register and immediately begin another conversion. When writing new configuration settings, the currently ongoing conversion completes with the previous configuration settings. Thereafter, continuous conversions with the new configuration settings start. To switch to single-shot conversion mode, write a 1 to the MODE bit in the configuration register or reset the device. 9.4.3 Duty Cycling For Low Power The noise performance of a ΔΣ ADC generally improves when lowering the output data rate because more samples of the internal modulator are averaged to yield one conversion result. In applications where power consumption is critical, the improved noise performance at low data rates may not be required. For these applications, the ADS111x support duty cycling that yield significant power savings by periodically requesting high data rate readings at an effectively lower data rate. For example, an ADS111x in power-down state with a data rate set to 860 SPS can be operated by a microcontroller that instructs a single-shot conversion every 125 ms (8 SPS). A conversion at 860 SPS only requires approximately 1.2 ms, so the ADS111x enter power-down state for the remaining 123.8 ms. In this configuration, the ADS111x consume approximately 1/100th the power that is otherwise consumed in continuous-conversion mode. The duty cycling rate is completely arbitrary and is defined by the master controller. The ADS111x offer lower data rates that do not implement duty cycling and also offer improved noise performance if required. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 21 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.5 Programming 9.5.1 I2C Interface The ADS111x communicate through an I2C interface. I2C is a two-wire open-drain interface that supports multiple devices and masters on a single bus. Devices on the I2C bus only drive the bus lines low by connecting them to ground; the devices never drive the bus lines high. Instead, the bus wires are pulled high by pullup resistors, so the bus wires are always high when no device is driving them low. As a result of this configuration, two devices cannot conflict. If two devices drive the bus simultaneously, there is no driver contention. Communication on the I2C bus always takes place between two devices, one acting as the master and the other as the slave. Both the master and slave can read and write, but the slave can only do so under the direction of the master. Some I2C devices can act as a master or slave, but the ADS111x can only act as a slave device. An I2C bus consists of two lines: SDA and SCL. SDA carries data; SCL provides the clock. All data are transmitted across the I2C bus in groups of eight bits. To send a bit on the I2C bus, drive the SDA line to the appropriate level while SCL is low (a low on SDA indicates the bit is zero; a high indicates the bit is one). After the SDA line settles, the SCL line is brought high, then low. This pulse on SCL clocks the SDA bit into the receiver shift register. If the I2C bus is held idle for more than 25 ms, the bus times out. The I2C bus is bidirectional; that is, the SDA line is used for both transmitting and receiving data. When the master reads from a slave, the slave drives the data line; when the master sends to a slave, the master drives the data line. The master always drives the clock line. The ADS111x cannot act as a master, and therefore can never drive SCL. Most of the time the bus is idle; no communication occurs, and both lines are high. When communication takes place, the bus is active. Only a master device can start a communication and initiate a START condition on the bus. Normally, the data line is only allowed to change state while the clock line is low. If the data line changes state while the clock line is high, it is either a START condition or a STOP condition. A START condition occurs when the clock line is high, and the data line goes from high to low. A STOP condition occurs when the clock line is high, and the data line goes from low to high. After the master issues a START condition, the master sends a byte that indicates with which slave device to communicate. This byte is called the address byte. Each device on an I2C bus has a unique 7-bit address to which it responds. The master sends an address in the address byte, together with a bit that indicates whether the master wishes to read from or write to the slave device. Every byte (address and data) transmitted on the I2C bus is acknowledged with an acknowledge bit. When the master finishes sending a byte (eight data bits) to a slave, the master stops driving SDA and waits for the slave to acknowledge the byte. The slave acknowledges the byte by pulling SDA low. The master then sends a clock pulse to clock the acknowledge bit. Similarly, when the master completes reading a byte, the master pulls SDA low to acknowledge this completion to the slave. The master then sends a clock pulse to clock the bit. The master always drives the clock line. If a device is not present on the bus, and the master attempts to address it, it receives a not-acknowledge because no device is present at that address to pull the line low. A not-acknowledge is performed by simply leaving SDA high during an acknowledge cycle. When the master has finished communicating with a slave, it may issue a STOP condition. When a STOP condition is issued, the bus becomes idle again. The master may also issue another START condition. When a START condition is issued while the bus is active, it is called a repeated start condition. The Timing Requirements section shows a timing diagram for the ADS111x I2C communication. 22 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Programming (continued) 9.5.1.1 I2C Address Selection The ADS111x have one address pin, ADDR, that configures the I2C address of the device. This pin can be connected to GND, VDD, SDA, or SCL, allowing for four different addresses to be selected with one pin, as shown in Table 4. The state of address pin ADDR is sampled continuously. Use the GND, VDD and SCL addresses first. If SDA is used as the device address, hold the SDA line low for at least 100 ns after the SCL line goes low to make sure the device decodes the address correctly during I2C communication. Table 4. ADDR Pin Connection and Corresponding Slave Address ADDR PIN CONNECTION SLAVE ADDRESS GND 1001000 VDD 1001001 SDA 1001010 SCL 1001011 2 9.5.1.2 I C General Call The ADS111x respond to the I2C general call address (0000000) if the eighth bit is 0. The devices acknowledge the general call address and respond to commands in the second byte. If the second byte is 00000110 (06h), the ADS111x reset the internal registers and enter a power-down state. 9.5.1.3 I2C Speed Modes The I2C bus operates at one of three speeds. Standard mode allows a clock frequency of up to 100 kHz; fast mode permits a clock frequency of up to 400 kHz; and high-speed mode (also called Hs mode) allows a clock frequency of up to 3.4 MHz. The ADS111x are fully compatible with all three modes. No special action is required to use the ADS111x in standard or fast mode, but high-speed mode must be activated. To activate high-speed mode, send a special address byte of 00001xxx following the START condition, where xxx are bits unique to the Hs-capable master. This byte is called the Hs master code, and is different from normal address bytes; the eighth bit does not indicate read/write status. The ADS111x do not acknowledge this byte; the I2C specification prohibits acknowledgment of the Hs master code. Upon receiving a master code, the ADS111x switch on Hs mode filters, and communicate at up to 3.4 MHz. The ADS111x switch out of Hs mode with the next STOP condition. For more information on high-speed mode, consult the I2C specification. 9.5.2 Slave Mode Operations The ADS111x act as slave receivers or slave transmitters. The ADS111x cannot drive the SCL line as slave devices. 9.5.2.1 Receive Mode In slave receive mode, the first byte transmitted from the master to the slave consists of the 7-bit device address followed by a low R/W bit. The next byte transmitted by the master is the Address Pointer register. The ADS111x then acknowledge receipt of the Address Pointer register byte. The next two bytes are written to the address given by the register address pointer bits, P[1:0]. The ADS111x acknowledge each byte sent. Register bytes are sent with the most significant byte first, followed by the least significant byte. 9.5.2.2 Transmit Mode In slave transmit mode, the first byte transmitted by the master is the 7-bit slave address followed by the high R/W bit. This byte places the slave into transmit mode and indicates that the ADS111x are being read from. The next byte transmitted by the slave is the most significant byte of the register that is indicated by the register address pointer bits, P[1:0]. This byte is followed by an acknowledgment from the master. The remaining least significant byte is then sent by the slave and is followed by an acknowledgment from the master. The master may terminate transmission after any byte by not acknowledging or issuing a START or STOP condition. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 23 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.5.3 Writing To and Reading From the Registers To access a specific register from the ADS111x, the master must first write an appropriate value to register address pointer bits P[1:0] in the Address Pointer register. The Address Pointer register is written to directly after the slave address byte, low R/W bit, and a successful slave acknowledgment. After the Address Pointer register is written, the slave acknowledges, and the master issues a STOP or a repeated START condition. When reading from the ADS111x, the previous value written to bits P[1:0] determines the register that is read. To change which register is read, a new value must be written to P[1:0]. To write a new value to P[1:0], the master issues a slave address byte with the R/W bit low, followed by the Address Pointer register byte. No additional data has to be transmitted, and a STOP condition can be issued by the master. The master can now issue a START condition and send the slave address byte with the R/W bit high to begin the read. Figure 37 details this sequence. If repeated reads from the same register are desired, there is no need to continually send the Address Pointer register, because the ADS111x store the value of P[1:0] until it is modified by a write operation. However, for every write operation, the Address Pointer register must be written with the appropriate values. 1 9 1 9 SCL ¼ SDA 1 0 0 1 0 A1 (1) (1) A0 0 R/W Start By Master 0 0 0 0 0 P1 ACK By ADS1113/4/5 P0 ACK By ADS1113/4/5 Stop By Master Frame 2: Address Pointer Register Frame 1: Slave Address Byte 1 9 1 9 SCL (Continued) ¼ SDA (Continued) 1 0 0 0 1 A1 (1) (1) A0 R/W Start By Master D15 D14 D13 D12 D11 ACK By ADS1113/4/5 D10 D9 D8 From ADS1113/4/5 ¼ ACK By Master (2) Frame 4: Data Byte 1 Read Register Frame 3: Slave Address Byte 1 9 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 From ADS1113/4/5 D1 D0 ACK By Master (3) Stop By Master Frame 5: Data Byte 2 Read Register (1) The values of A0 and A1 are determined by the ADDR pin. (2) Master can leave SDA high to terminate a single-byte read operation. (3) Master can leave SDA high to terminate a two-byte read operation. Figure 30. Timing Diagram for Reading From ADS111x 24 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 1 9 9 1 SCL ¼ 1 SDA 0 0 1 A1(1) 0 A0(1) R/W Start By Master 0 0 0 0 0 0 P1 P0 ACK By ADS1113/4/5 ¼ ACK By ADS1113/4/5 Frame 2: Address Pointer Register Frame 1: Slave Address Byte 9 1 1 9 SCL (Continued) SDA (Continued) D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 ACK By ADS1113/4/5 ACK By ADS1113/4/5 Stop By Master Frame 4: Data Byte 2 Frame 3: Data Byte 1 (1) D0 The values of A0 and A1 are determined by the ADDR pin. Figure 31. Timing Diagram for Writing to ADS111x ALERT 1 9 1 9 SCL SDA 0 0 0 1 1 Start By Master 0 0 R/W 0 0 1 ACK By ADS1113/4/5 Frame 1: SMBus ALERT Response Address Byte (1) 1 A1 A0 From ADS1113/4/5 Status NACK By Master Stop By Master Frame 2: Slave Address The values of A0 and A1 are determined by the ADDR pin. Figure 32. Timing Diagram for SMBus Alert Response Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 25 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.5.4 Data Format The ADS111x provide 16 bits of data in binary two's complement format. A positive full-scale (+FS) input produces an output code of 7FFFh and a negative full-scale (–FS) input produces an output code of 8000h. The output clips at these codes for signals that exceed full-scale. Table 5 summarizes the ideal output codes for different input signals. Figure 33 shows code transitions versus input voltage. Table 5. Input Signal Versus Ideal Output Code INPUT SIGNAL VIN = (VAINP – VAINN) IDEAL OUTPUT CODE(1) (1) ≥ +FS (215 – 1)/215 7FFFh 15 0001h 0 0000h –FS/215 FFFFh ≤ –FS 8000h +FS/2 (1) Excludes the effects of noise, INL, offset, and gain errors. 7FFFh 0001h 0000h FFFFh ... Output Code ... 7FFEh 8001h 8000h ... -FS 2 15 -FS 2 0 ... +FS Input Voltage VIN 2 -1 15 15 +FS 2 -1 15 Figure 33. Code Transition Diagram NOTE Single-ended signal measurements, where VAINN = 0 V and VAINP = 0 V to +FS, only use the positive code range from 0000h to 7FFFh. However, because of device offset, the ADS111x can still output negative codes in case VAINP is close to 0 V. 26 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 9.6 Register Map The ADS111x have four registers that are accessible through the I2C interface using the Address Pointer register. The Conversion register contains the result of the last conversion. The Config register is used to change the ADS111x operating modes and query the status of the device. The other two registers, Lo_thresh and Hi_thresh, set the threshold values used for the comparator function, and are not available in the ADS1113. 9.6.1 Address Pointer Register (address = N/A) [reset = N/A] All four registers are accessed by writing to the Address Pointer register; see Figure 30. Figure 34. Address Pointer Register 7 0 W-0h 6 0 W-0h 5 0 W-0h 4 0 W-0h 3 0 W-0h 2 0 W-0h 1 0 P[1:0] W-0h LEGEND: R/W = Read/Write; R = Read only; W = Write only; -n = value after reset Table 6. Address Pointer Register Field Descriptions Bit Field Type Reset Description 7:2 Reserved W 0h Always write 0h 1:0 P[1:0] W 0h Register address pointer 00 01 10 11 : : : : Conversion register Config register Lo_thresh register Hi_thresh register 9.6.2 Conversion Register (P[1:0] = 0h) [reset = 0000h] The 16-bit Conversion register contains the result of the last conversion in binary two's complement format. Following power-up, the Conversion register is cleared to 0, and remains 0 until the first conversion is completed. Figure 35. Conversion Register 15 D15 R-0h 7 D7 R-0h 14 D14 R-0h 6 D6 R-0h 13 D13 R-0h 5 D5 R-0h 12 D12 R-0h 4 D4 R-0h 11 D11 R-0h 3 D3 R-0h 10 D10 R-0h 2 D2 R-0h 9 D9 R-0h 1 D1 R-0h 8 D8 R-0h 0 D0 R-0h LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Table 7. Conversion Register Field Descriptions Bit 15:0 Field Type Reset Description D[15:0] R 0000h 16-bit conversion result Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 27 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.6.3 Config Register (P[1:0] = 1h) [reset = 8583h] The 16-bit Config register is used to control the operating mode, input selection, data rate, full-scale range, and comparator modes. Figure 36. Config Register 15 OS R/W-1h 7 14 6 DR[2:0] R/W-4h 13 MUX[2:0] R/W-0h 5 12 11 4 COMP_MODE R/W-0h 3 COMP_POL R/W-0h 10 PGA[2:0] R/W-2h 2 COMP_LAT R/W-0h 9 8 MODE R/W-1h 1 0 COMP_QUE[1:0] R/W-3h LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Table 8. Config Register Field Descriptions Bit Field Type Reset Description Operational status or single-shot conversion start This bit determines the operational status of the device. OS can only be written when in power-down state and has no effect when a conversion is ongoing. 15 OS R/W 1h When writing: 0 : No effect 1 : Start a single conversion (when in power-down state) When reading: 0 : Device is currently performing a conversion 1 : Device is not currently performing a conversion Input multiplexer configuration (ADS1115 only) These bits configure the input multiplexer. These bits serve no function on the ADS1113 and ADS1114. 14:12 MUX[2:0] R/W 0h 000 : 001 : 010 : 011 : 100 : 101 : 110 : 111 : AINP AINP AINP AINP AINP AINP AINP AINP = AIN0 = AIN0 = AIN1 = AIN2 = AIN0 = AIN1 = AIN2 = AIN3 and AINN = AIN1 (default) and AINN = AIN3 and AINN = AIN3 and AINN = AIN3 and AINN = GND and AINN = GND and AINN = GND and AINN = GND Programmable gain amplifier configuration These bits set the FSR of the programmable gain amplifier. These bits serve no function on the ADS1113. 11:9 8 PGA[2:0] MODE R/W R/W 2h 1h 000 : 001 : 010 : 011 : 100 : 101 : 110 : 111 : FSR = ±6.144 FSR = ±4.096 FSR = ±2.048 FSR = ±1.024 FSR = ±0.512 FSR = ±0.256 FSR = ±0.256 FSR = ±0.256 V (1) V (1) V (default) V V V V V Device operating mode This bit controls the operating mode. 0 : Continuous-conversion mode 1 : Single-shot mode or power-down state (default) Data rate These bits control the data rate setting. 7:5 (1) 28 DR[2:0] R/W 4h 000 : 001 : 010 : 011 : 100 : 101 : 110 : 111 : 8 SPS 16 SPS 32 SPS 64 SPS 128 SPS (default) 250 SPS 475 SPS 860 SPS This parameter expresses the full-scale range of the ADC scaling. Do not apply more than VDD + 0.3 V to the analog inputs of the device. Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Table 8. Config Register Field Descriptions (continued) Bit 4 Field COMP_MODE Type R/W Reset Description 0h Comparator mode (ADS1114 and ADS1115 only) This bit configures the comparator operating mode. This bit serves no function on the ADS1113. 0 : Traditional comparator (default) 1 : Window comparator 3 COMP_POL R/W 0h Comparator polarity (ADS1114 and ADS1115 only) This bit controls the polarity of the ALERT/RDY pin. This bit serves no function on the ADS1113. 0 : Active low (default) 1 : Active high Latching comparator (ADS1114 and ADS1115 only) This bit controls whether the ALERT/RDY pin latches after being asserted or clears after conversions are within the margin of the upper and lower threshold values. This bit serves no function on the ADS1113. 2 1:0 COMP_LAT COMP_QUE[1:0] R/W R/W 0h 3h 0 : Nonlatching comparator . The ALERT/RDY pin does not latch when asserted (default). 1 : Latching comparator. The asserted ALERT/RDY pin remains latched until conversion data are read by the master or an appropriate SMBus alert response is sent by the master. The device responds with its address, and it is the lowest address currently asserting the ALERT/RDY bus line. Comparator queue and disable (ADS1114 and ADS1115 only) These bits perform two functions. When set to 11, the comparator is disabled and the ALERT/RDY pin is set to a high-impedance state. When set to any other value, the ALERT/RDY pin and the comparator function are enabled, and the set value determines the number of successive conversions exceeding the upper or lower threshold required before asserting the ALERT/RDY pin. These bits serve no function on the ADS1113. 00 01 10 11 : : : : Assert after one conversion Assert after two conversions Assert after four conversions Disable comparator and set ALERT/RDY pin to high-impedance (default) Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 29 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 9.6.4 Lo_thresh (P[1:0] = 2h) [reset = 8000h] and Hi_thresh (P[1:0] = 3h) [reset = 7FFFh] Registers The upper and lower threshold values used by the comparator are stored in two 16-bit registers in two's complement format. The comparator is implemented as a digital comparator; therefore, the values in these registers must be updated whenever the PGA settings are changed. The conversion-ready function of the ALERT/RDY pin is enabled by setting the Hi_thresh register MSB to 1 and the Lo_thresh register MSB to 0. To use the comparator function of the ALERT/RDY pin, the Hi_thresh register value must always be greater than the Lo_thresh register value. The threshold register formats are shown in Figure 37. When set to RDY mode, the ALERT/RDY pin outputs the OS bit when in single-shot mode, and provides a continuous-conversion ready pulse when in continuous-conversion mode. Figure 37. Lo_thresh Register 15 Lo_thresh15 R/W-1h 7 Lo_thresh7 R/W-0h 14 Lo_thresh14 R/W-0h 6 Lo_thresh6 R/W-0h 13 Lo_thresh13 R/W-0h 5 Lo_thresh5 R/W-0h 12 Lo_thresh12 R/W-0h 4 Lo_thresh4 R/W-0h 11 Lo_thresh11 R/W-0h 3 Lo_thresh3 R/W-0h 10 Lo_thresh10 R/W-0h 2 Lo_thresh2 R/W-0h 9 Lo_thresh9 R/W-0h 1 Lo_thresh1 R/W-0h 8 Lo_thresh8 R/W-0h 0 Lo_thresh0 R/W-0h 10 Hi_thresh10 R/W-1h 2 Hi_thresh2 R/W-1h 9 Hi_thresh9 R/W-1h 1 Hi_thresh1 R/W-1h 8 Hi_thresh8 R/W-1h 0 Hi_thresh0 R/W-1h LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Figure 38. Hi_thresh Register 15 Hi_thresh15 R/W-0h 7 Hi_thresh7 R/W-1h 14 Hi_thresh14 R/W-1h 6 Hi_thresh6 R/W-1h 13 Hi_thresh13 R/W-1h 5 Hi_thresh5 R/W-1h 12 Hi_thresh12 R/W-1h 4 Hi_thresh4 R/W-1h 11 Hi_thresh11 R/W-1h 3 Hi_thresh3 R/W-1h LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Table 9. Lo_thresh and Hi_thresh Register Field Descriptions Bit 30 Field Type Reset Description 15:0 Lo_thresh[15:0] R/W 8000h Low threshold value 15:0 Hi_thresh[15:0] R/W 7FFFh High threshold value Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 10 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 10.1 Application Information The following sections give example circuits and suggestions for using the ADS111x in various situations. 10.1.1 Basic Connections The principle I2C connections for the ADS1115 are shown in Figure 39. 10 ADS1115 1-k to 10-k (typ) Pullup Resistors VDD Microcontroller or Microprocessor with I2C Port VDD SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 0.1 …F (typ) AIN1 5 SCL SDA GPIO Inputs Selected from Configuration Register Copyright © 2016, Texas Instruments Incorporated Figure 39. Typical Connections of the ADS1115 The fully-differential voltage input of the ADS111x is ideal for connection to differential sources with moderately low source impedance, such as thermocouples and thermistors. Although the ADS111x can read bipolar differential signals, these devices cannot accept negative voltages on either input. The ADS111x draw transient currents during conversion. A 0.1-μF power-supply bypass capacitor supplies the momentary bursts of extra current required from the supply. The ADS111x interface directly to standard mode, fast mode, and high-speed mode I2C controllers. Any microcontroller I2C peripheral, including master-only and single-master I2C peripherals, operates with the ADS111x. The ADS111x does not perform clock-stretching (that is, the device never pulls the clock line low), so it is not necessary to provide for this function unless other clock-stretching devices are on the same I2C bus. Pullup resistors are required on both the SDA and SCL lines because I2C bus drivers are open drain. The size of these resistors depends on the bus operating speed and capacitance of the bus lines. Higher-value resistors consume less power, but increase the transition times on the bus, thus limiting the bus speed. Lower-value resistors allow higher speed, but at the expense of higher power consumption. Long bus lines have higher capacitance and require smaller pullup resistors to compensate. Do not use resistors that are too small because the bus drivers may not be able to pull the bus lines low. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 31 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Application Information (continued) 10.1.2 Single-Ended Inputs The ADS1113 and ADS1114 can measure one, and the ADS1115 up to four, single-ended signals. The ADS1113 and ADS1114 can measure single-ended signals by connecting AIN1 to GND externally. The ADS1115 measures single-ended signals by appropriate configuration of the MUX[2:0] bits in the Config register. Figure 40 shows a single-ended connection scheme for ADS1115. The single-ended signal ranges from 0 V up to positive supply or +FS, whichever is lower. Negative voltages cannot be applied to these devices because the ADS111x can only accept positive voltages with respect to ground. The ADS111x do not lose linearity within the input range. The ADS111x offer a differential input voltage range of ±FSR. Single-ended configurations use only one-half of the full-scale input voltage range. Differential configurations maximize the dynamic range of the ADC, and provide better common-mode noise rejection than single-ended configurations. VDD Output Codes 0-32767 10 ADS1115 SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 0.1 F (typ) AIN1 5 Inputs Selected from Configuration Register Copyright © 2016, Texas Instruments Incorporated NOTE: Digital pin connections omitted for clarity. Figure 40. Measuring Single-Ended Inputs The ADS1115 also allows AIN3 to serve as a common point for measurements by appropriate setting of the MUX[2:0] bits. AIN0, AIN1, and AIN2 can all be measured with respect to AIN3. In this configuration, the ADS1115 operates with inputs, where AIN3 serves as the common point. This ability improves the usable range over the single-ended configuration because negative differential voltages are allowed when GND < V(AIN3) < VDD; however, common-mode noise attenuation is not offered. 10.1.3 Input Protection The ADS111x are fabricated in a small-geometry, low-voltage process. The analog inputs feature protection diodes to the supply rails. However, the current-handling ability of these diodes is limited, and the ADS111x can be permanently damaged by analog input voltages that exceed approximately 300 mV beyond the rails for extended periods. One way to protect against overvoltage is to place current-limiting resistors on the input lines. The ADS111x analog inputs can withstand continuous currents as large as 10 mA. 10.1.4 Unused Inputs and Outputs Either float unused analog inputs, or tie the unused analog inputs to midsupply or VDD. Connecting unused analog inputs to GND is possible, but may yield higher leakage currents than the previous options. Either float NC (not-connected) pins, or tie the NC pins to GND. If the ALERT/RDY output pin is not used, leave the pin unconnected or tie the pin to VDD using a weak pullup resistor. 32 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Application Information (continued) 10.1.5 Analog Input Filtering Analog input filtering serves two purposes: 1. Limits the effect of aliasing during the sampling process 2. Reduces external noise from being a part of the measurement Aliasing occurs when frequency components are present in the input signal that are higher than half the sampling frequency of the ADC (also known as the Nyquist frequency). These frequency components fold back and show up in the actual frequency band of interest below half the sampling frequency. The filter response of the digital filter repeats at multiples of the sampling frequency, also known as the modulator frequency (fMOD), as shown in Figure 41. Signals or noise up to a frequency where the filter response repeats are attenuated to a certain amount by the digital filter depending on the filter architecture. Any frequency components present in the input signal around the modulator frequency, or multiples thereof, are not attenuated and alias back into the band of interest, unless attenuated by an external analog filter. Magnitude Sensor Signal Output Data Rate Magnitude Unwanted Signals Unwanted Signals fMOD / 2 fMOD Frequency fMOD Frequency fMOD Frequency Digital Filter Aliasing of Unwanted Signals Output Data Rate fMOD / 2 Magnitude External Antialiasing Filter Roll-Off Output Data Rate fMOD / 2 Figure 41. Effect of Aliasing Many sensor signals are inherently band-limited; for example, the output of a thermocouple has a limited rate of change. In this case, the sensor signal does not alias back into the pass-band when using a ΔΣ ADC. However, any noise pick-up along the sensor wiring or the application circuitry can potentially alias into the pass-band. Power line-cycle frequency and harmonics are one common noise source. External noise can also be generated from electromagnetic interference (EMI) or radio frequency interference (RFI) sources, such as nearby motors and cellular phones. Another noise source typically exists on the printed-circuit-board (PCB) itself in the form of clocks and other digital signals. Analog input filtering helps remove unwanted signals from affecting the measurement result. A first-order resistor-capacitor (RC) filter is (in most cases) sufficient to either totally eliminate aliasing, or to reduce the effect of aliasing to a level within the noise floor of the sensor. Ideally, any signal beyond fMOD / 2 is attenuated to a level below the noise floor of the ADC. The digital filter of the ADS111x attenuate signals to a certain degree, as shown in Figure 21. In addition, noise components are usually smaller in magnitude than the actual sensor signal. Therefore, use a first-order RC filter with a cutoff frequency set at the output data rate or 10x higher as a generally good starting point for a system design. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 33 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com Application Information (continued) 10.1.6 Connecting Multiple Devices It is possible to connect up to four ADS111x devices to a single I2C bus using different address pin configurations for each device. Use the address pin to set the ADS111x to one of four different I2C addresses. Use the GND, VDD and SCL addresses first. If SDA is used as the device address, hold the SDA line low for at least 100 ns after the SCL line goes low to make sure the device decodes the address correctly during I2C communication. An example showing four ADS111x devices on the same I2C bus is shown in Figure 42. One set of pullup resistors is required per bus. The pullup resistor values may need to be lowered to compensate for the additional bus capacitance presented by multiple devices and increased line length. VDD GND 10 ADS1115 1-k to 10-k (typ) I2C Pullup Resistors Microcontroller or Microprocessor With I2C Port VDD SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 AIN1 5 SCL SDA 10 ADS1115 SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 AIN1 5 10 ADS1115 SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 AIN1 5 10 ADS1115 SCL 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 AIN1 5 Copyright © 2016, Texas Instruments Incorporated NOTE: ADS111x power and input connections omitted for clarity. The ADDR pin selects the I2C address. Figure 42. Connecting Multiple ADS111x Devices 34 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 Application Information (continued) 10.1.7 Quickstart Guide This section provides a brief example of ADS111x communications. See subsequent sections of this data sheet for more detailed explanations. Hardware for this design includes: one ADS111x configured with an I2C address of 1001000; a microcontroller with an I2C interface; discrete components such as resistors, capacitors, and serial connectors; and a 2 V to 5 V power supply. Figure 43 shows the basic hardware configuration. The ADS111x communicate with the master (microcontroller) through an I2C interface. The master provides a clock signal on the SCL pin and data are transferred using the SDA pin. The ADS111x never drive the SCL pin. For information on programming and debugging the microcontroller being used, see the device-specific product data sheet. The first byte sent by the master is the ADS111x address, followed by the R/W bit that instructs the ADS111x to listen for a subsequent byte. The second byte is the Address Pointer register byte. The third and fourth bytes sent from the master are written to the register indicated in register address pointer bits P[1:0]. See Figure 30 and Figure 31 for read and write operation timing diagrams, respectively. All read and write transactions with the ADS111x must be preceded by a START condition, and followed by a STOP condition. For example, to write to the configuration register to set the ADS111x to continuous-conversion mode and then read the conversion result, send the following bytes in this order: 1. Write to Config register: – First byte: 0b10010000 (first 7-bit I2C address followed by a low R/W bit) – Second byte: 0b00000001 (points to Config register) – Third byte: 0b10000100 (MSB of the Config register to be written) – Fourth byte: 0b10000011 (LSB of the Config register to be written) 2. Write to Address Pointer register: – First byte: 0b10010000 (first 7-bit I2C address followed by a low R/W bit) – Second byte: 0b00000000 (points to Conversion register) 3. Read Conversion register: – First byte: 0b10010001 (first 7-bit I2C address followed by a high R/W bit) – Second byte: the ADS111x response with the MSB of the Conversion register – Third byte: the ADS111x response with the LSB of the Conversion register 3.3 V ADS111x VDD 0.1 µF GND 2 3.3 V I C-Capable Master (MSP430F2002) AIN0 AIN1 3.3 V ADDR AIN2 (ADS1115 Only) AIN3 (ADS1115 Only) 10 k 10 k SCL SCL (P1.6) SDA SDA (P1.7) VDD 0.1 µF GND ALERT (ADS1114/5 Only) JTAG Serial/UART Copyright © 2016, Texas Instruments Incorporated Figure 43. Basic Hardware Configuration Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 35 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 10.2 Typical Application Shunt-based, current-measurement solutions are widely used to monitor load currents. Low-side, current-shunt measurements are independent of the bus voltage because the shunt common-mode voltage is near ground. Figure 44 shows an example circuit for a bidirectional, low-side, current-shunt measurement system. The load current is determined by measuring the voltage across the shunt resistor that is amplified and level-shifted by a low-drift operational amplifier, OPA333. The OPA333 output voltage is digitized with ADS1115 and sent to the microcontroller using the I2C interface. This circuit is capable of measuring bidirectional currents flowing through the shunt resistor with great accuracy and precision. High-Voltage Bus VCM VDD VDD CCM2 LOAD R6 AINN ILOAD VINX RSHUNT 4-Wire Kelvin Connection R3 R4 VSHUNT + OPA333 ± VOUT CDIFF ADS1115 I2C R5 AINP R1 CCM1 R2 Figure 44. Low-Side Current Shunt Monitoring 10.2.1 Design Requirements Table 10 shows the design parameters for this application. Table 10. Design Parameters DESIGN PARAMETER VALUE Supply voltage (VDD) 5V Voltage across Shunt Resistor (VSHUNT) ±50 mV ≥200 readings per second Output Data Rate (DR) Typical measurement accuracy at TA = 25°C (1) (1) ±0.2% Does not account for inaccuracy of shunt resistor and the precision resistors used in the application. 10.2.2 Detailed Design Procedure The first stage of the application circuit consists of an OPA333 in a noninverting summing amplifier configuration and serves two purposes: 1. To level-shift the ground-referenced signal to allow bidirectional current measurements while running off a unipolar supply. The voltage across the shunt resistor, VSHUNT, is level-shifted by a common-mode voltage, VCM, as shown in Figure 44. The level-shifted voltage, VINX, at the noninverting input is given by Equation 5. VINX = (VCM · R3 + VSHUNT · R4) / (R3 + R4) (5) 2. To amplify the level-shifted voltage (VINX). The OPA333 is configured in a noninverting gain configuration with the output voltage, VOUT, given by Equation 6. VOUT = VINX · (1 + R2 / R1) (6) Using Equation 5 and Equation 6, VOUT is given as a function of VSHUNT and VCM by Equation 7. VOUT = (VCM · R3 + VSHUNT · R4) / (R3 + R4) · (1 + R2 / R1) (7) Using Equation 7 the ADC differential input voltage, before the first-order RC filter, is given by Equation 8. VOUT – VCM = VSHUNT · (1 + R2 / R1) / (1 + R4 / R3) + VCM · (R2 / R1 – R3 / R4) / (1 + R3 / R4) (8) If R1 = R3 and R2 = R4, Equation 8 is simplified to Equation 9. VOUT – VCM = VSHUNT · (1 + R2 / R1) / (1 + R4 / R3) 36 Submit Documentation Feedback (9) Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 10.2.2.1 Shunt Resistor Considerations A shunt resistor (RSHUNT) is an accurate resistance inserted in series with the load as shown in Figure 44. If the absolute voltage drop across the shunt, |VSHUNT|, is a larger percentage of the bus voltage, the voltage drop may reduce the overall efficiency and system performance. If |VSHUNT| is too low, measuring the small voltage drop requires careful design attention and proper selection of the ADC, operation amplifier, and precision resistors. Make sure that the absolute voltage at the shunt terminals does not result in violation of the input common-mode voltage range requirements of the operational amplifier. The power dissipation on the shunt resistor increases the temperature because of the current flowing through it. To minimize the measurement errors due to variation in temperature, select a low-drift shunt resistor. To minimize the measurement gain error, select a shunt resistor with low tolerance value. To remove the errors due to stray ground resistance, use a four-wire Kelvin-connected shunt resistor, as shown in Figure 44. 10.2.2.2 Operational Amplifier Considerations The operational amplifier used for this design example requires the following features: • Unipolar supply operation (5 V) • Low input offset voltage (< 10 µV) and input offset voltage drift (< 0.5 µV/°C) • Rail-to-rail input and output capability • Low thermal and flicker noise • High common-mode rejection (> 100 dB) OPA333 offers all these benefits and is selected for this application. 10.2.2.3 ADC Input Common-Mode Considerations VCM sets the VOUT common-mode voltage by appropriate selection of precision resistors R1, R2, R3, and R4. If R1 = R3, R2 = R4, and VSHUNT = 0 V, VOUT is given by Equation 10. VOUT = VCM (10) If VOUT is connected to the ADC positive input (AINP) and VCM is connected to the ADC negative input (AINN), VCM appears as a common-mode voltage to the ADC. This configuration allows pseudo-differential measurements and uses the maximum dynamic range of the ADC if VCM is set at midsupply (VDD / 2). A resistor divider from VDD to GND followed by a buffer amplifier can be used to generate VCM. 10.2.2.4 Resistor (R1, R2, R3, R4) Considerations Proper selection of resistors R1, R2, R3 and R4 is critical for meeting the overall accuracy requirements. Using Equation 8, the offset term, VOUT-OS, and the gain term, AOUT, of the differential ADC input are represented by Equation 11 and Equation 12 respectively. The error contributions from the first-order RC filters are ignored. VOUT-OS = VCM · (R2 / R1 - R3 / R4) / (1 + R3 / R4) AOUT = (1 + R2 / R1) / (1 + R4 / R3) (11) (12) The tolerance, drift and linearity performance of these resistors is critical to meeting the overall accuracy requirements. In Equation 11, if R1 = R3 and R2 = R4, VOUT-OS = 0 V and therefore, the common-mode voltage, VCM, only contributes to level-shift VSHUNT and does not introduce any error at the differential ADC inputs. Highprecision resistors provide better common-mode rejection from VCM. 10.2.2.5 Noise and Input Impedance Considerations If vn_res represents the input-referred rms noise from all the resistors, vn_op represents the input-referred rms noise of OPA333, and vn_ADC represents the input-referred rms noise of ADS1115, the total input-referred noise of the entire system, vN, can be approximated by Equation 13. vN2 = vn_res2 + vn_op2 + vn_ADC/ (1 + R2 / R1)2 (13) It is important to note that the ADC noise contribution, vn_ADC, is attenuated by the non-inverting gain stage. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 37 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com If the gain of the noninverting gain stage is high (≥ 5), a good approximation for vn_res2 is given by Equation 14. The noise contribution from resistors R2, R4, R5, and R6 when referred to the input is smaller in comparison to R1 and R3 and can be neglected for approximation purposes. vn_res2 = 4 · k · T · (R1 + R3) · Δf where • • • where k = Boltzmann constant T = temperature (in kelvins) Δf = noise bandwidth (14) An approximation for the input impedance, RIN, of the application circuit is given by Equation 15. RIN can be modeled as a resistor in parallel with the shunt resistor, and can contribute to additional gain error. RIN = R3 + R4 (15) From Equation 14 and Equation 15, a trade-off exists between vN and RIN. If R3 increases, vn_res increases, and therefore, the total input-referred rms system noise, vN, increases. If R3 decreases, the input impedance, RIN, drops, and causes additional gain error. 10.2.2.6 First-order RC Filter Considerations Although the device digital filter attenuates high-frequency noise, use a first order low-pass RC filter at the ADC inputs to further reject out-of-bandwidth noise and avoid aliasing. A differential low-pass RC filter formed by R5, R6, and the differential capacitor CDIFF sets the –3-dB cutoff frequency, fC, given by Equation 16. These filter resistors produce a voltage drop because of the input currents flowing into and out of the ADC. This voltage drop could contribute to an additional gain error. Limit the filter resistor values to below 1 kΩ. fC = 1 / [2π · (R5 + R6) · CDIFF] (16) Two common-mode filter capacitors (CCM1 and CCM2) are also added to offer attenuation of high-frequency, common-mode noise components. Select a differential capacitor, CDIFF, that is at least an order of magnitude (10x) larger than these common-mode capacitors because mismatches in these common-mode capacitors can convert common-mode noise into differential noise. 10.2.2.7 Circuit Implementation Table 11 shows the chosen values for this design. Table 11. Parameters PARAMETER (1) VALUE VCM 2.5 V FSR of ADC ±0.256 V Output Data Rate 250 SPS R1, R3 1 kΩ (1) R2, R4 5 kΩ (1) R5, R6 100 Ω (1) CDIFF 0.22 µF CCM1, CCM2 0.022 µF 1% precision resistors used Using Equation 7, if VSHUNT ranges from –50 mV to +50 mV, the application circuit produces a differential voltage ranging from –0.250 V to +0.250 V across the ADC inputs . The ADC is therefore configured at a FSR of ±0.256 V to maximize the dynamic range of the ADC. The –3 dB cutoff frequencies of the differential low-pass filter and the common-mode low-pass filters are set at 3.6 kHz and 0.36 kHz, respectively. RSHUNT typically ranges from 0.01 mΩ to 100 mΩ. Therefore, if R1 = R3 = 1 kΩ, a good trade-off exists between the circuit input impedance and input referred resistor noise as explained in the Noise and Input Impedance Considerations section. A simple resistor divider followed by a buffer amplifier is used to generate VCM of 2.5 V from a 5-V supply. 38 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 10.2.2.8 Results Summary A precision voltage source is used to sweep VSHUNT from –50 mV to +50 mV. The application circuit produces a differential voltage of –250 mV to +250 mV across the ADC inputs. Figure 45 and Figure 46 show the measurement results. The measurements are taken at TA = 25°C. Although 1% tolerance resistors are used, the exact value of these resistors are measured with a Fluke 4.5 digit multimeter to exclude the errors due to inaccuracy of these resistors. In Figure 45, the x-axis represents VSHUNT and the black line represents the measured digital output voltage in mV. In Figure 46, the x-axis represents VSHUNT, the black line represents the total measurement error in %, the blue line represents the total measurement error in % after excluding the errors from precision resistors and the green line represents the total measurement error in % after excluding the errors from precision resistors and performing a system offset calibration with VSHUNT = 0 V. Table 12 shows a results summary. Table 12. Results Summary (1) PARAMETER VALUE Total error, including errors from 1% precision resistors 1.89% Total error, excluding errors from 1% precision resistors 0.17% Total error, after offset calibration, excluding errors from 1% precision resistors 0.11% (1) TA = 25°C, not accounting for inaccuracy of shunt resistor. 10.2.3 Application Curves 250 150 Measurement Error ( ) Measured Output (mV) 200 100 50 0 -50 -100 -150 -200 -250 -60 -50 -40 -30 -20 -10 0 10 20 Shunt Voltage (mV) 30 40 50 60 2 1.75 1.5 1.25 1 0.75 0.5 0.25 0 -0.25 -0.5 -0.75 -1 -1.25 -1.5 -1.75 -2 -50 Including all errors Excluding resistor errors Excluding resistor errors, after offset calibration -40 -30 -20 D004 Figure 45. Measured Output vs Shunt Voltage (VSHUNT) -10 0 10 20 Shunt Voltage (mV) 30 40 50 D005 Figure 46. Measurement Error vs Shunt Voltage (VSHUNT) Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 39 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 11 Power Supply Recommendations The device requires a single unipolar supply, VDD, to power both the analog and digital circuitry of the device. 11.1 Power-Supply Sequencing Wait approximately 50 µs after VDD is stabilized before communicating with the device to allow the power-up reset process to complete. 11.2 Power-Supply Decoupling Good power-supply decoupling is important to achieve optimum performance. VDD must be decoupled with at least a 0.1-µF capacitor, as shown in Figure 47. The 0.1-μF bypass capacitor supplies the momentary bursts of extra current required from the supply when the device is converting. Place the bypass capacitor as close to the power-supply pin of the device as possible using low-impedance connections. Use multilayer ceramic chip capacitors (MLCCs) that offer low equivalent series resistance (ESR) and inductance (ESL) characteristics for power-supply decoupling purposes. For very sensitive systems, or for systems in harsh noise environments, avoid the use of vias for connecting the capacitors to the device pins for better noise immunity. The use of multiple vias in parallel lowers the overall inductance, and is beneficial for connections to ground planes. VDD TI Device 10 DIN 1 ADDR SDA 9 2 ALERT/RDY VDD 8 3 GND AIN3 7 4 AIN0 AIN2 6 0.1 µF AIN1 5 Figure 47. ADS1115 Power-Supply Decoupling 40 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 12 Layout 12.1 Layout Guidelines Employ best design practices when laying out a printed-circuit board (PCB) for both analog and digital components. For optimal performance, separate the analog components [such as ADCs, amplifiers, references, digital-to-analog converters (DACs), and analog MUXs] from digital components [such as microcontrollers, complex programmable logic devices (CPLDs), field-programmable gate arrays (FPGAs), radio frequency (RF) transceivers, universal serial bus (USB) transceivers, and switching regulators]. An example of good component placement is shown in Figure 48. Although Figure 48 provides a good example of component placement, the best placement for each application is unique to the geometries, components, and PCB fabrication capabilities employed. That is, there is no single layout that is perfect for every design and careful consideration must always be used when designing with any analog component. Ground Fill or Ground Plane Supply Generation Microcontroller Device Optional: Split Ground Cut Signal Conditioning (RC Filters and Amplifiers) Ground Fill or Ground Plane Optional: Split Ground Cut Ground Fill or Ground Plane Interface Transceiver Connector or Antenna Ground Fill or Ground Plane Figure 48. System Component Placement The following outlines some basic recommendations for the layout of the ADS111x to get the best possible performance of the ADC. A good design can be ruined with a bad circuit layout. • • • • • • • Separate analog and digital signals. To start, partition the board into analog and digital sections where the layout permits. Route digital lines away from analog lines. This prevents digital noise from coupling back into analog signals. Fill void areas on signal layers with ground fill. Provide good ground return paths. Signal return currents flow on the path of least impedance. If the ground plane is cut or has other traces that block the current from flowing right next to the signal trace, it has to find another path to return to the source and complete the circuit. If it is forced into a larger path, it increases the chance that the signal radiates. Sensitive signals are more susceptible to EMI interference. Use bypass capacitors on supplies to reduce high-frequency noise. Do not place vias between bypass capacitors and the active device. Placing the bypass capacitors on the same layer as close to the active device yields the best results. Consider the resistance and inductance of the routing. Often, traces for the inputs have resistances that react with the input bias current and cause an added error voltage. Reduce the loop area enclosed by the source signal and the return current in order to reduce the inductance in the path. Reduce the inductance to reduce the EMI pickup, and reduce the high frequency impedance seen by the device. Differential inputs must be matched for both the inputs going to the measurement source. Analog inputs with differential connections must have a capacitor placed differentially across the inputs. Best input combinations for differential measurements use adjacent analog input lines such as AIN0, AIN1 and AIN2, AIN3. The differential capacitors must be of high quality. The best ceramic chip capacitors are C0G (NPO), which have stable properties and low-noise characteristics. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 41 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com SDA SCL ADDR ALERT/RDY 12.2 Layout Example VDD 10 SCL 1 ADDR 2 ALERT/RDY SDA 9 VDD 8 AIN3 TI Device 3 GND 4 AIN0 AIN1 AIN3 7 AIN2 6 5 Vias connect to either bottom layer or an internal plane. The bottom layer or internal plane are dedicated GND planes AIN1 AIN0 AIN2 SCL SDA ADDR ALERT/RDY Figure 49. ADS1115 X2QFN Package VDD 1 ADDR 2 ALERT/RDY 3 GND 4 5 SCL 10 SDA 9 VDD 8 AIN0 AIN3 7 AIN1 AIN2 6 AIN3 AIN0 TI Device AIN2 AIN1 Vias connect to either bottom layer or an internal plane. The bottom layer or internal plane are dedicated GND planes Figure 50. ADS1115 VSSOP Package 42 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 ADS1113, ADS1114, ADS1115 www.ti.com SBAS444D – MAY 2009 – REVISED JANUARY 2018 13 Device and Documentation Support 13.1 Documentation Support 13.1.1 Related Documentation For related documentation see the following: • OPAx333 1.8-V, microPower, CMOS Operational Amplifiers, Zero-Drift Series (SBOS351) • MSP430F20x1, MSP430F20x2, MSP430F20x3 Mixed Signal Microcontroller (SLAS491) • TIDA-00824 Human Skin Temperature Sensing for Wearable Applications Reference Design (TIDUAY7) 13.2 Related Links The following table lists quick access links. Categories include technical documents, support and community resources, tools and software, and quick access to sample or buy. Table 13. Related Links PARTS PRODUCT FOLDER SAMPLE & BUY TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY ADS1113 Click here Click here Click here Click here Click here ADS1114 Click here Click here Click here Click here Click here ADS1115 Click here Click here Click here Click here Click here 13.3 Receiving Notification of Documentation Updates To receive notification of documentation updates, navigate to the device product folder on ti.com. In the upper right corner, click on Alert me to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document. 13.4 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 13.5 Trademarks E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners. 13.6 Electrostatic Discharge Caution This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. 13.7 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 Submit Documentation Feedback 43 ADS1113, ADS1114, ADS1115 SBAS444D – MAY 2009 – REVISED JANUARY 2018 www.ti.com 14 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. 44 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Product Folder Links: ADS1113 ADS1114 ADS1115 PACKAGE OPTION ADDENDUM www.ti.com 10-Nov-2021 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) ADS1113IDGSR ACTIVE VSSOP DGS 10 2500 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BROI ADS1113IDGST ACTIVE VSSOP DGS 10 250 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BROI ADS1113IRUGR ACTIVE X2QFN RUG 10 3000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N6J ADS1113IRUGT ACTIVE X2QFN RUG 10 250 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N6J ADS1114IDGSR ACTIVE VSSOP DGS 10 2500 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BRNI ADS1114IDGST ACTIVE VSSOP DGS 10 250 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BRNI ADS1114IRUGR ACTIVE X2QFN RUG 10 3000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N5J ADS1114IRUGT ACTIVE X2QFN RUG 10 250 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N5J ADS1115IDGSR ACTIVE VSSOP DGS 10 2500 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BOGI ADS1115IDGST ACTIVE VSSOP DGS 10 250 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 BOGI ADS1115IRUGR ACTIVE X2QFN RUG 10 3000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N4J ADS1115IRUGT ACTIVE X2QFN RUG 10 250 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 N4J (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
ADS1115BQDGSRQ1 价格&库存

很抱歉,暂时无法提供与“ADS1115BQDGSRQ1”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ADS1115BQDGSRQ1
  •  国内价格 香港价格
  • 2500+28.100512500+3.48586

库存:2513

ADS1115BQDGSRQ1
  •  国内价格 香港价格
  • 1+49.900181+6.19010
  • 10+38.2211910+4.74132
  • 25+35.3087125+4.38003
  • 100+32.10528100+3.98265
  • 250+30.57807250+3.79320
  • 500+29.65780500+3.67904
  • 1000+28.900211000+3.58506

库存:2513