User's Guide
SBAU144D – March 2009 – Revised May 2016
ADS1282EVM and ADS1282EVM-PDK User's Guide
ADS1282EVM (Left) and ADS1282EVM-PDK (Right)
This user's guide describes the characteristics, operation, and use of the ADS1282EVM, both by itself and
as part of the ADS1282EVM-PDK. This evaluation model (EVM) is an evaluation board for the ADS1282,
a high-performance, 32-bit multi-channel, delta-sigma analog-to-digital converter (ADC). The EVM allows
evaluation of all aspects of the ADS1282. Complete circuit descriptions, schematic diagrams, and bills of
material are included in this document.
The following related documents are available for download through the Texas Instruments web site at
http://www.ti.com.
EVM-Compatible Device Data Sheets
Device
Literature Number
Device
Literature Number
ADS1282
SBAS418E
SN74LVC2G157
SCES207K
REF5025
SBOS410C
SN74LVC1G07
SCES296W
REF5050
SBOS410C
SN74AHCT1G04
SCLS319N
OPA2350
SBOS099C
TPS79225
SLVS337B
OPA1632
SBOS286A
TPS72325
SLVS346B
PCA9535
SCPS129H
ADCPro is a trademark of Texas Instruments.
SPI is a trademark of Motorola Inc.
I2C is a trademark of NXP Semiconductors.
NI-VISA is a trademark of National Instruments.
All other trademarks are the property of their respective owners.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
1
www.ti.com
1
2
3
4
5
6
7
8
9
10
11
12
Contents
EVM Overview ............................................................................................................... 3
Analog Interface.............................................................................................................. 3
Digital Interface .............................................................................................................. 4
Power Supplies .............................................................................................................. 5
Voltage Reference ........................................................................................................... 6
Power-Down, Mode and Format Control ................................................................................. 6
Clock Source ................................................................................................................. 6
EVM Operation ............................................................................................................... 7
ADS1282EVM-PDK Kit Operation ......................................................................................... 8
Running the Software and Completing Driver Installation ............................................................ 13
Evaluating Performance with the ADCPro Software ................................................................... 21
Schematics and Layout .................................................................................................... 26
List of Figures
1
Connectors for J7 ............................................................................................................ 5
2
Switch S1 ..................................................................................................................... 6
3
Jumper J3 ..................................................................................................................... 6
4
ADS1282EVM Default Jumper Locations
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
................................................................................ 7
MMB0 Initial Setup........................................................................................................... 9
Connecting ADS1282EVM to MMB0 .................................................................................... 10
Using the +6V Wall Supply for +5V ...................................................................................... 11
Using a External Supply For +5V ........................................................................................ 12
NI-VISA Driver Installation ................................................................................................ 13
NI-VISA Driver Installation Prompt ....................................................................................... 14
NI-VISA Driver Installing................................................................................................... 14
NI-VISA Driver Complete Installation .................................................................................... 15
NI-VISA Driver Verification Using Device Manager .................................................................... 15
ADCPro Software Start-up Display Window ............................................................................ 16
ADS1282EVM-PDK Plug-In Display Window........................................................................... 17
Install New Driver Wizard, Screen 1 ..................................................................................... 18
Install New Driver Wizard, Screen 2 ..................................................................................... 18
Install New Driver Wizard, Screen 3 ..................................................................................... 19
Install New Driver Wizard, Screen 4 ..................................................................................... 19
Install New Driver Wizard, Screen 5 ..................................................................................... 20
USBStyx Driver Verification Using Device Manager ................................................................... 20
Data Rate Select ........................................................................................................... 21
PGA Gain Select ........................................................................................................... 21
Mux Select .................................................................................................................. 22
Controls Tab ................................................................................................................ 22
Digital Filter ................................................................................................................. 23
Filter Tab .................................................................................................................... 23
Calibration ................................................................................................................... 24
Progress Bar While Collecting Data ..................................................................................... 25
List of Tables
2
1
J6: Analog Interface Pinout ................................................................................................. 4
2
J5: Serial Interface Pins ..................................................................................................... 4
3
J3 Configuration: Power-Supply Input
4
ADS1282EVM Bill of Materials
.................................................................................... 5
.......................................................................................... 26
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
EVM Overview
www.ti.com
1
EVM Overview
1.1
Features
ADS1282EVM:
• Contains all support circuitry needed for the ADS1282
• Voltage reference options: external or onboard
• Clock options: External clock source or 4.096MHz onboard crystal oscillator
• Compatible with the TI Modular EVM System
ADS1282EVM-PDK/ADS1282EVM-PDK Features:
• Easy-to-use evaluation software for Microsoft® Windows® XP
• Data collection to text files
• Built-in analysis tools including scope, FFT, and histogram displays
• Complete control of board settings
• Easily expandable with new analysis plug-in tools from Texas Instruments
For use with a computer, the ADS1282EVM-PDK is available. This kit combines the ADS1282EVM board
with the DSP-based MMB0 motherboard, and includes ADCPro™ software for evaluation.
The MMB0 motherboard allows the ADS1282EVM to be connected to the computer via an available USB
port. This manual shows how to use the MMB0 as part of the ADS1282EVM-PDK, but does not provide
technical details about the MMB0 itself.
ADCPro is a program for collecting, recording, and analyzing data from ADC evaluation boards. It is based
on a number of plug-in programs, so it can be expanded easily with new test and data collection plug-ins.
The ADS1282EVM-PDK is controlled by a plug-in that runs in ADCPro. For more information about
ADCPro, see the ADCPro™ Analog-to-Digital Converter Evalutation Software User's Guide (literature
number SBAU128), available for download from the TI web site.
This manual covers the operation of both the ADS1282EVM and the ADS1282EVM-PDK. Throughout this
document, the abbreviation EVM and the term evaluation module are synonymous with the
ADS1282EVM.
1.2
Introduction
The ADS1282EVM is an evaluation module built to the TI Modular EVM System specification. It can be
connected to any modular EVM system interface card.
The ADS1282EVM is available as a stand-alone printed circuit board (PCB) or as part of the
ADS1282EVM-PDK, which includes an MMB0 motherboard and software. As a stand-alone PCB, the
ADS1282EVM is useful for prototyping designs and firmware.
Note that the ADS1282EVM has no microprocessor and cannot run software. To connect it to a computer,
some type of interface is required.
2
Analog Interface
For maximum flexibility, the ADS1282EVM is designed for easy interfacing to multiple analog sources.
Samtec part numbers SSW-110-22-F-D-VS-K and TSM-110-01-T-DV-P provide a convenient 10-pin, dualrow, header/socket combination at J6. This header/socket provides access to the analog input pins of the
ADS1282. Consult Samtec at http://www.samtec.com or call 1-800-SAMTEC-9 for a variety of mating
connector options.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
3
Digital Interface
www.ti.com
The input pins on the ADS1282EVM are directly connected to the part, with no filtering or protection. It is
important that appropriate caution is taken when handling the pins. Table 1 summarizes the pinouts for
analog interface J6.
Table 1. J6: Analog Interface Pinout
Pin Number
Signal
J6.1
A1N
AINN1, ADS1282
Description
J6.2
A1P
AINP1, ADS1282
J6.3
A2N
AINN2, ADS1282
J6.4
A2P
AINP2, ADS1282
J6.9-13 (odd)
AGND
J6.15
VCOM
J6.17-19 (odd
AGND
Analog ground connections
J6.18
REFN
External reference source input
(– side of differential input)
J6.20
REFP
External reference source input
(+ side of differential input)
J6.5-8
Unused
J6.10-16 (even)
Unused
3
Digital Interface
3.1
Serial Data Interface
Analog ground connections
The ADS1282EVM is designed to easily interface with multiple control platforms. Samtec part numbers
SSW-110-22-F-D-VS-K and TSM-110-01-T-DV-P provide a convenient 10-pin, dual-row, header/socket
combination at J5. This header/socket provides access to the digital control and serial data pins of the
ADC. Consult Samtec at http://www.samtec.com or call 1-800-SAMTEC-9 for a variety of mating
connector options.
All logic levels on J5 are 3.3V CMOS, except for the I2C™ pins. These pins conform to 3.3V I2C rules.
Table 2 describes the J5 serial interface pins.
Table 2. J5: Serial Interface Pins
4
Pin No.
Pin Name
Signal Name
J5.1
CNTL
Unused
J5.2
GPIO0
M0
I/O Type
Pullup
Function
In/Out
Low
Data rate select input /
Modulator data output
J5.3
CLKX
SCLK
In
None
ADS1282 SPI™ clock
J5.4
DGND
DGND
In/Out
None
Digital ground
J5.5
CLKR
Unused
J5.6
GPIO1
M1
In/Out
High
Data rate select input /
Modulator data output
J5.7
FSX
Unused
J5.8
GPIO2
MCLK
Out
Low
Modulator clock output
J5.9
FSR
DRDY
Out
None
Data ready signal
J5.10
DGND
DGND
In/Out
None
Digital ground
J5.11
DX
MOD/DIN
In
None
ADS1282 SPI data in
J5.12
GPIO3
SUPSOR
In
High
Power-supply regulator
Hi = +5 V Lo = ±2.5 V
J5.13
DR
DOUT
Out
None
ADS1282 data out
J5.14
GPIO4
PDWN
In
High
Power-down input
J5.15
INT
DRDY
Out
None
Data ready signal
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Power Supplies
www.ti.com
Table 2. J5: Serial Interface Pins (continued)
Pin No.
Pin Name
Signal Name
I/O Type
Pullup
J5.16
SCL
SCL
I2C
n/a
Function
J5.17
TOUT
CLK
In
None
Can be used to provide
a clock from a
processor
J5.18
DGND
DGND
In/Out
None
Digital ground
J5.19
GPIO5
EXTCLK
In
None
External clock input
J5.20
SDA
SDA
I2C
n/a
I2C clock
I2C data
Many pins on J5 have weak pull-up/-down resistors. These resistors provide default settings for many of
the control pins. Many pins on J5 correspond directly to ADS1282 pins. See the ADS1282 product data
sheet for complete details on these pins.
4
Power Supplies
J8 is the power-supply input connector. Table 3 lists the configuration details for J8. Analog inputs to the
ADC can be applied directly to the device (see Section 8.1, Analog Input). An additional bipolar supply is
needed to power the bipolar amplifiers. For optimum noise performance, the external supplies (+VA and
–VA) should be used.
Table 3. J3 Configuration: Power-Supply Input
4.1
Pin No.
Pin Name
Function
Required
J8.1
+VA
+10V to +15V
Yes
J8.2
–VA
–10V to –15V
Yes
J8.3
+5VA
+5V analog supply
Always
J8.4
–5VA
–5V analog supply
No; only for bipolar
mode
J8.5
DGND
Digital ground input
Yes
J8.6
AGND
Analog ground input
Yes
J8.7
+1.8VD
1.8V digital supply
No
J8.8
VD1
Not used
No
J8.9
+3.3VD
3.3V digital supply
Always
J8.10
+5VD
+5V
No
Bipolar Power Options
The voltage used to power the operational amplifiers is +10V and –10V pins J8.1 and J8.2. If using bipolar
mode ±5V supplies must be connected to pins J8.3 and J8.4. The ±5V is regulated down to ±2.5V with
U10 and U13 in bipolar mode. Jumpers must be properly placed across J7.1 and J7.2 as well as J7.3 and
J7.4 to properly power the ADS1282 (shown in Figure 1).
Figure 1. Connectors for J7
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
5
Voltage Reference
5
www.ti.com
Voltage Reference
The ADS1282EVM has many options for supplying a reference voltage to the ADS1282. Jumper J1 can
select the voltage from the REF5050 (U1) or use ground. The REF5050 supplies 5.0V to the reference for
unipolar mode. If ground is selected, then the voltage reference becomes 2.5V in bipolar mode. This
comes from the voltage difference across the VREFP and VREFN pins on the ADS1282. The voltage is
filtered and buffered by U3 before it is used as a reference for the ADS1282.
The ADS1282 can also be referenced by an external reference voltage using pins J6.18 (REF–) and J6.20
(REF+). Switch S1 chooses either the onboard reference or the external reference voltage that is
connected to the pins of J6. Figure 2 shows switch S1 as it appears on the EVM.
Figure 2. Switch S1
6
Power-Down, Mode and Format Control
The power-down functionality of the ADS1282 is controlled by GPIO4 (J5.14) on the EVM. The
ADS1282EVM-PDK uses the I2C port expander on the EVM to allow the software to control this pin.
7
Clock Source
The ADS1282 clock can come from one of two sources: the onboard 4.096MHz crystal oscillator, or a
clock supplied by a processor on the TOUT pin (J5.17).
7.1
Usage in PDK
If using the ADS1282EVM as part of the ADS1282EVM-PDK, the J3 jumper should be set to the DVDD
position. Using the onboard 4.096MHz crystal oscillator allows the the ADS1282EVM-PDK software to
recognize the EVM using the software provided.
7.2
Usage as a Stand-Alone EVM
If using the EVM in your own system and not with the PDK hardware and software, the J3 jumper can be
used to select the clock. The jumper can be used to always select the 4.096MHz crystal (DVDD position)
or allow the onboard clock to be controlled by GPIO5 (J5.19), as shown in Figure 3. The P05 (U7.6) pin
allows the I2C interface to program a clock to GPIO5.
Figure 3. Jumper J3
6
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
EVM Operation
www.ti.com
8
EVM Operation
This section provides information on the analog input, digital control, and general operating conditions of
the ADS1282EVM.
8.1
Analog Input
The two differential input sources can be applied directly to J6 (top or bottom side) or through signalconditioning modules available for the modular EVM system. Each input is connected directly through an
OPA1632 buffer before reaching the ADS1282. The Common-Mode Voltage (VCOM) for the input buffer
operational amplifiers is 2.5V supplied from the REF5025.
8.2
Digital Control
The digital control signals can be applied directly to J5 (top or bottom side). The modular ADS1282EVM
can also be connected directly to a DSP or microcontroller interface board, such as the 5-6K Interface
EVM or HPA-MCU Interface boards available from Texas Instruments, or the MMB0 if purchased as part
of the ADS1282EVM-PDK. For a list of compatible interface and/or accessory boards for the EVM or the
ADS1282, see the relevant product folder on the TI web site. Some of the digital signals are controlled
directly with pins on J5. Other signals, such as SYNC, MFLAG, PMODE, and RESET controls, can only
be controlled by U7. These signals are configured and read using the I2C signals on pins 16 and 20 of J5.
The Format and Mode pins can be controlled by both methods (GPIO pins on J5, and the I2C control from
U7).
8.3
Default Jumper Settings and Switch Positions
Figure 4 shows the jumpers found on the EVM and the respective factory default conditions for each.
Figure 4. ADS1282EVM Default Jumper Locations
There is only one switch, S1, located on the ADS1282EVM; it is used to set the reference voltage (VREF).
The default position is to the left, indicating that the EVM is to use the onboard reference voltage.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
7
ADS1282EVM-PDK Kit Operation
9
www.ti.com
ADS1282EVM-PDK Kit Operation
This section provides information on using the ADS1282EVM-PDK, including setup, program installation,
and program usage.
To prepare
Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
Step 7.
to evaluate the ADS1282 with the ADS1282EVM-PDK, complete the following steps:
Install the ADCPro software (if not already installed) on a PC.
Install the ADS1282EVM-PDK EVM plug-in software.
Set up the ADS1282EVM-PDK.
Connect a proper power supply or ac adapter.
Complete the NI-VISA™ USB driver installation process.
Run the ADCPro software.
Complete the Microsoft Windows USB driver installation process.
Each task is described in the subsequent sections of this document.
9.1
Installing the ADCPro Software
CAUTION
Do not connect the ADS1282EVM-PDK before installing the software on a
suitable PC. Failure to observe this caution may cause Microsoft Windows to
not recognize the ADS1282EVM-PDK as an connected device.
The latest software is available from the TI website at http://www.ti.com/tool/ADS1282EVM-PDK. The
ADCPro software can be downloaded directly from the TI web site (http://www.ti.com/adcpro). Refer to the
ADCPro User Guide for instructions on installing and using ADCPro.
To install the ADS1282EVM-PDK plug-in, run the file: ads1282evm-pdk-plugin-1.0.0.exe (1.0.0 is the
version number, and increments with software version releases). Double-click the file to run it; then follow
the instructions shown.
The software should now be installed, but the USB drivers may not yet have been loaded by the PC
operating system. This step will complete when the ADCPro software is executed; see Section 10,
Running the Software and Completing Driver Installation.
8
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM-PDK Kit Operation
www.ti.com
9.2
Setting Up the ADS1282EVM-PDK
The ADS1282EVM-PDK contains both the ADS1282EVM and the MMB0 motherboard; however, the
devices are shipped unconnected. Follow these steps to set up the ADS1282EVM-PDK.
Step 1. Unpack the ADS1282EVM-PDK kit.
Step 2. Set the jumpers and switches on the MMB0 as shown in Figure 5.
• Set the Boot Mode switch to USB.
• Set jumper J4 low to indicate that the EVM board is an ADS1282EVM.
Figure 5. MMB0 Initial Setup
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
9
ADS1282EVM-PDK Kit Operation
www.ti.com
3. Plug the ADS1282EVM into the MMB0 as Figure 6 illustrates.
Figure 6. Connecting ADS1282EVM to MMB0
CAUTION
Do not misalign the pins when plugging the ADS1282EVM into the MMB0.
Check the pin alignment carefully before applying power to the PDK.
9.2.1
About the MMB0
The MMB0 is a Modular EVM System motherboard. It is designed around the TMS320VC5507, a DSP
with an onboard USB interface from Texas Instruments. The MMB0 also has 16MB of SDRAM installed.
The MMB0 is not sold as a DSP development board, and it is not available separately. TI cannot offer
support for the MMB0 except as part of an EVM kit. For schematics or other information about the MMB0,
contact Texas Instruments.
10
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM-PDK Kit Operation
www.ti.com
9.3
Connecting the Power Supply
The ADS1282EVM-PDK requires both a +5V supply and a bipolar ±10-V supply to operate. The +5V
supply can be provided by either a wall supply or bench power supply.
When the MMB0 DSP is powered properly, LED D2 glows green. The green light indicates that the 3.3V
supply for the MMB0 is operating properly. (It does not indicate that the EVM power supplies are
operating properly.)
9.3.1
Using a Wall Supply for +5V
An ac wall supply can be connected to barrel jack J2 on the MMB0 to supply the +5V required for
operation. J2 is located next to the USB connector.
Jumper J12 on the MMB0 connects a wall-mounted power supply to the board. To use a wall-mount
supply, J12 must be shorted. Figure 7 illustrates how to connect an ac adapter to the MMB0.
J2
J12
AC ADAPTER INPUT
WALL SUPPLY CONNECTION
J13
POWER
SUPPLY
CONFIG
J14
POWER
INPUT
-10V
+10V
Figure 7. Using the +6V Wall Supply for +5V
9.3.1.1
External Wall-Adapter Power-Supply Requirements
The external wall-adapter power-supply requirements are as follows:
• Output voltage: 6 VDC to 7 VDC
• Maximum output current: ≥ 2 A
• Output connector: barrel plug (positive center), 2.0-mm I.D. × 5.5-mm O.D. (9-mm insertion depth)
NOTE: Use an external power supply that complies with applicable regional safety standards; for
example, UL, CSA, VDE, CCC, PSE, and so forth.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
11
ADS1282EVM-PDK Kit Operation
9.3.2
www.ti.com
Using an External Supply For +5V
A laboratory power supply can be connected through terminal block J14 on the MMB0, as shown in
Figure 8, to provide the +5V required for operation.
To
•
•
•
use a lab power supply for +5V:
Disconnect J12 on the MMB0. This disconnect the barrel jack, J2, from powering the +5V supply.
Connect a +5V dc supply to the +5VA and GND terminals on J14.
Make sure that the external supply can source 2A of current to the board.
J12
WALL SUPPLY DISCONNECT
J13
POWER
SUPPLY
CONFIG
J14
POWER
INPUT
GND
+5VDC
(OPTIONAL) -5VDC
-10V
+10V
Figure 8. Using a External Supply For +5V
9.3.3
Connecting the External Bipolar Supplies
An external bipolar supply of ±10V is required for proper operation of the EVM. These supplies can be
connected to the terminal block J14 on the MMB0.
Connect the –10V dc supply to –VA, and +10V dc to +VA terminals on J14.
9.3.4
Power For Bipolar Mode versus Unipolar Mode
The ADS1252EVM allows for operation of the device in either unipolar or bipolar mode. Depending on the
mode, the power supply requirements can differ.
For operation in unipolar mode, no additional supplies are required other than those specified in
Section 9.3.1 to Section 9.3.3.
For operation in bipolar mode, an additional -5V supply is required. Connect at –5V supply to – 5VA
terminal of J14. It is not necessary to connect a +5V dc supply voltage to the +5VA terminal on J14 if the
+5V/+5VA position on J13 is shorted.
12
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Running the Software and Completing Driver Installation
www.ti.com
10
Running the Software and Completing Driver Installation
Note: The software is continually under development. These instructions and screen images are current at
the time of this writing, but may not exactly match future releases.
The program for evaluating the ADS1282EVM-PDK is called ADCPro. This program uses plug-ins to
communicate with the EVM. The ADS1282EVM-PDK plug-in is included in the ADS1282EVM-PDK
package.
The program currently runs only on Microsoft Windows platforms of Windows XP; Windows Vista is NOT
supported.
If this is the first time to install ADCPro and the plug-ins, follow these procedures to run ADCPro and
complete the necessary driver installation. Make sure the ADCPro software and device plug-in software
are installed from the CD-ROM as described in Section 9.1, Installing the ADCPro Software.
10.1 NI-VISA USB Device Driver Installation
1. After the ADCPro software is installed, apply power to the PDK and connect the board to an available
PC USB port.
2. The computer should recognize new hardware and begin installing the drivers for the hardware.
Figure 9 through Figure 12 are provided for reference to show the installation steps.
• For the first screen, Figure 9, it is not necessary to search for the software; it has already been
installed to your PC.
• For the remaining steps, accept the default settings.
Figure 9. NI-VISA Driver Installation
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
13
Running the Software and Completing Driver Installation
www.ti.com
Figure 10. NI-VISA Driver Installation Prompt
Figure 11. NI-VISA Driver Installing
14
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Running the Software and Completing Driver Installation
www.ti.com
Figure 12. NI-VISA Driver Complete Installation
This process should complete the installation of the NI-VISA drivers. You can verify proper installation by
opening the Device Manager and locating the hardware as shown in Figure 13.
Figure 13. NI-VISA Driver Verification Using Device Manager
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
15
Running the Software and Completing Driver Installation
www.ti.com
10.2 USBStyx Driver Installation
Step 1.
Start the software by selecting ADCPro from the Windows Start menu. The screen in
Figure 14 appears.
Figure 14. ADCPro Software Start-up Display Window
16
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Running the Software and Completing Driver Installation
www.ti.com
2. Select ADS1282EVM from the EVM drop-down menu. The ADS1282EVM-PDK plug-in appears in the
left pane, as shown in Figure 15.
Figure 15. ADS1282EVM-PDK Plug-In Display Window
Step 2.
Step 3.
The ADS1282EVM-PDK plug-in window has a status area at the top of the screen. When the
plug-in is first loaded, the plug-in searches for the board. You will see a series of messages
in the status area indicating this action.
If you have not yet loaded the operating system drivers, Windows will display the Windows
Install New Driver Wizard sequence (illustrated in Figure 16 through Figure 20). Accept the
default settings.
NOTE: During the driver installation, a message may appear indicating the firmware load has timed
out. Click OK and continue driver installation. The plug-in will attempt to download the
firmware again once the driver installation completes.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
17
Running the Software and Completing Driver Installation
www.ti.com
Figure 16. Install New Driver Wizard, Screen 1
Figure 17. Install New Driver Wizard, Screen 2
18
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Running the Software and Completing Driver Installation
www.ti.com
Figure 18. Install New Driver Wizard, Screen 3
Figure 19. Install New Driver Wizard, Screen 4
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
19
Running the Software and Completing Driver Installation
www.ti.com
Figure 20. Install New Driver Wizard, Screen 5
Step 4.
Step 5.
Once Windows finishes installing the software driver, the plug-in downloads the firmware to
the MMB0. The status area will display Connected to EVM when the device is connected and
ready to use. If the firmware does not load properly, you can try resetting the MMB0 by
pressing Reset and then reloading the plug-in.
You can verify the proper installation of the USBStyx driver using the Device Manager. Note
that the first driver item, NI-VISA USB Devices, will disappear and a new item, LibUSBWin32 Devices will appear, as Figure 21 shows.
Figure 21. USBStyx Driver Verification Using Device Manager
The driver installation wizard sequence should not appear again, unless you connect the board to a
different USB port.
20
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Evaluating Performance with the ADCPro Software
www.ti.com
11
Evaluating Performance with the ADCPro Software
The evaluation software is based on ADCPro, a program that operates using a variety of plug-ins. (The
ADS1282EVM plug-in is installed as described in the installation section, Section 10.)
To use ADCPro, load an EVM plug-in and a test plug-in. To load an EVM plug-in, select it from the EVM
menu. To load a test plug-in, select it from the Test menu. To unload a plug-in, select the Unload option
from the corresponding menu.
Only one of each kind of plug-in can be loaded at a time. If you select a different plug-in, the previous
plug-in is unloaded.
11.1 Using the ADS1282EVM-PDK Plug-in
The ADS1282EVM-PDK plug-in for ADCPro provides complete control over all settings of the ADS1282. It
consists of a tabbed interface (see Figure 15), with different functions available on different tabs. These
controls are described in this section.
You can adjust the ADS1282EVM settings when you are not acquiring data. During acquisition, all
controls are disabled and settings may not be changed.
When you change a setting on the ADS1282EVM plug-in, the setting immediately updates on the board.
Settings on the ADS1282EVM correspond to settings described in the ADS1282 product data sheet; see
the ADS1282 data sheet (available for download at the TI web site) for details.
11.1.1
Controls Tab
ADCPro can receive data from the ADS1282 at five different data rates. The data rate is controlled by the
DR[2:0] Register control (shown in Figure 22). The data rate choices are determined by the digital filter
that is used. The setting of the register selects the data rate and displays it to the right of the screen.
Figure 22. Data Rate Select
The PGA found on the ADS1282 can be set through ADCPro. The Gain control is used to set binary gains
by setting the register bits accordingly (as shown in Figure 23).
Figure 23. PGA Gain Select
ADCPro can access to the Chop control. Chop will take two readings, a normal reading and one with the
input pins switched. It then averages the two readings for a final output result. Doing this averaging
removes the offset, offset drift, and reduces the noise reading. See the ADS1282 product data sheet for
more information on Chop.
The Operating Mode control allows optimization of noise and power. Either Low Power or High
Resolution can be selected.
NOTE: Low-power mode is no longer supported
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
21
Evaluating Performance with the ADCPro Software
www.ti.com
The Mux control determines which input channel is sent through the converter. The five options, shown in
Figure 24, are explained in the product data sheet.
Figure 24. Mux Select
When switch S1 is switched to external VREF, VREFP and VREFN control the bounds for the reference
voltage.
The Standby and Wakeup controls send the corresponding commands to the ADS1282 (as illustrated in
Figure 25). Data cannot be collected while the device is in Standby mode.
Figure 25. Controls Tab
22
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Evaluating Performance with the ADCPro Software
www.ti.com
11.1.2
Filter Tab
There are three different digital filter options in ADCPro. A Sinc Filter + LPF Filter Block is the default filter.
The Low-Pass Filter (LPF) can be removed or a High-Pass Filter (HPF) can be added (as shown in
Figure 26).
Figure 26. Digital Filter
The LPF Phase Response control can be set to either Linear phase or Maximum phase. The Digital
Filter, LPF Phase Response and the High-pass Filter Corner Frequency are controlled in the Filter
Tab (as Figure 27 shows).
Figure 27. Filter Tab
11.1.3
Calibration Tab
A calibration feature is integrated into the ADS1282 to correct for offset and gain errors. The
ADS1282EVM-PDK software is designed to allow the user to use either the built-in system calibration
commands or manually calibrate the device by directly entering the values for the offset and gain registers
of the ADS1282.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
23
Evaluating Performance with the ADCPro Software
11.1.3.1
www.ti.com
System Calibration
The Start Calibration button is used for system calibration by sending the Offset and Gain Calibration
commands to the ADS1282. Which command is sent is determined by the radio buttons in the Calibration
Type groupbox (see Figure 28). The calibrations should be performed separately before testing. See the
ADS1282 product data sheet for more information on calibration.
A zero input signal must be applied before performing offset calibration. The Offset radio button should be
selected. When Start Calibration is pushed, the offset calibration is performed and the resulting value is
reflected in the OFC register display (in hex).
A full-scale dc input should be applied for gain calibration. The Gain radio button should be selected.
When Start Calibration is pushed, the gain calibration is performed and the resulting value is reflected in
the FSC register display (in hex).
11.1.3.2
Manual Calibration
The values of the offset (OFC) and full-scale (FSC) calibration registers can be directly written to if there
are different offset and gain values desired to be used. The OFC or FSC registers are written to the
ADS1282 when the value in these controls changes and the user deselects the text box. For ease of
entry, the gain or offset values are entered only in the OFC or FSC controls; the actual values placed in
each of the three corresponding registers on the ADS1282 are displayed on this tab.
Figure 28. Calibration
24
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Evaluating Performance with the ADCPro Software
www.ti.com
11.1.4
Collecting Data
Once you have configured the ADS1282 for your test scenario, press the ADCPro Acquire button to start
the collection of the number of datapoints specified in the Test plug-in Block Size control. The
ADS1282EVM-PDK plug-in disables all the front panel controls while acquiring, and displays a progress
bar as shown in Figure 29.
Figure 29. Progress Bar While Collecting Data
For more information on testing analog-to-digital converters in general and using ADCPro and Test plugins, refer to the ADCPro User Guide.
11.2 Troubleshooting
If ADCPro stops responding while the ADS1282EVM-PDK is connected, try unplugging the power supply
from the PDK. Unload and reload the plug-in before reapplying power to the PDK.
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
25
Schematics and Layout
12
www.ti.com
Schematics and Layout
Schematics for the ADS1282EVM are appended to this user's guide. The bill of materials is provided in
Table 4.
12.1 Bill of Materials
NOTE:
All components should be compliant with the European Union Restriction on Use of
Hazardous Substances (RoHS) Directive. Some part numbers may be either leaded or
RoHS. Verify that purchased components are RoHS-compliant. (For more information about
TI's position on RoHS compliance, see the Quality and Eco-Info information on the TI web
site.)
Table 4. ADS1282EVM Bill of Materials
Item No.
Qty
Value
Ref Des
1
2
0
R4, R5
Resistor, Thick Film Chip, 0Ω, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEY0R00V
2
7
47
R3, R6-R11
Resistor, Thick Film Chip, 47Ω, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ470V
3
8
1k
R16-R23
Resistor, Thick Film Chip, 1kΩ, 1%,
1/16W, Size = 0603
Panasonic
ERJ-3EKF1001V
4
1
2k
R2
Resistor, Thick Film Chip, 2kΩ, 1%,
1/16W, Size = 0603
Panasonic
ERJ-3EKF2001V
5
1
10k
R1
Resistor, Thick Film Chip, 10kΩ, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ103V
6
1
47k
R24
Resistor, Thick Film Chip, 47kΩ, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ473V
7
5
100k
R12-R15, R27
Resistor, Thick Film Chip, 100kΩ, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ104V
Not Installed
1
100k
R28
Resistor, Thick Film Chip, 100kΩ, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ104V
8
2
470k
R25, R26
Resistor, Thick Film Chip, 470kΩ, 5%,
1/10W, Size = 0603
Panasonic
ERJ-3GEYJ474V
9
2
100k
RA1, RA2
Resistor, 8 Thick Film Chip Array,
100kΩ, 5%, 63mW
CTS
745C101104JPTR
Not Installed
1
100k
RA3
Resistor, Chip Array 4 Independent
Bus, 100kΩ, 5%, 1/16W, SMD
CTS
741C083104JP
10
6
1nF
C11-C14, C21, C22
Capacitor, C0G Ceramic 1nF ±5%,
50WV, Size = 0603
TDK
C1608C0G1H102JT
11
2
10nF
C27, C32
Capacitor, C0G Ceramic 10nF ±5%,
25WV, Size = 0603
TDK
C1608C0G1E103JT
12
7
0.1μF
C4, C5, C7, C28,
C29, C35, C36
Capacitor, X7R Ceramic 0.1μF ±10%,
25WV, Size = 0603
TDK
C1608X7R1E104KT
13
1
0.15μF
C6
Capacitor, X7R Ceramic 0.15μF
±10%, 25WV, Size = 0603
TDK
C1608X7R1E154KT
14
6
1μF
C1, C10, C25, C26,
C33, C34
Capacitor, X7R Ceramic 1μF ±10%,
16WV, Size = 0603
TDK
C1608X7R1C105KT
15
2
1μF
C8, C9
Capacitor, X7R Ceramic 1μF ±10%,
50WV, Size = 1206
TDK
C3216X7R1H105KT
16
2
10μF
C17, C20
Capacitor, X5R Ceramic 10μF ±20%,
6.3WV, Size = 0805
TDK
C2012X5R0J106MT
17
4
10μF
C23, C24, C30, C31
Capacitor, X7R Ceramic 10μF ±20%,
16WV, Size = 1206
TDK
C3216X7R1C106MT
18
4
10μF
C15, C16, C18, C19
Capacitor, X7R Ceramic 10μF ±20%,
25WV, Size = 1210
DK
C3225X7R1E106MT
19
2
22μF
C2, C3
Capacitor, X5R Ceramic 22μF ±20%,
16WV, Size = 1210
TDK
C3225X5R1C226MT
20
1
U6
Precision Delta-Sigma ADC, 2
Differential Input, 24-bit
Texas
Instruments
ADS1282IPW
21
1
U3
Precision Operational Amplifier
Texas
Instruments
OPA227U
26
Description
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
Vendor
Part Number
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Schematics and Layout
www.ti.com
Table 4. ADS1282EVM Bill of Materials (continued)
Item No.
Qty
22
2
Value
U4
U5,Fully-Differential Amplifier
Texas
Instruments
OPA1632DGN
23
1
U2
Precision Voltage Reference, 2.5V
Texas
Instruments
REF5025ID
24
1
U1
Precision Voltage Reference, 5V
Texas
Instruments
REF5050ID
25
1
U8
Inverter, Single Gate
Texas
Instruments
SN74AHCT1G04DBVT
26
1
U9
Buffer, Open Drain, Single Gate
Texas
Instruments
SN74LVC1G07DBVT
27
1
U11
Single, 2-Line to 1 Data
Selector/Multiplexer
Texas
Instruments
SN74LVC2G157DCTR
28
1
U13
LDO Voltage Regulator, 2.5V, 200mA
Texas
Instruments
TPS72325DBVT
29
1
U10
LDO Voltage Regulator, 2.5V, 100mA
Texas
Instruments
TPS79225DBVT
30
1
U7
16-Bit I2C I/O Expander
Texas
Instruments
PCA9535RGE
31
1
U12
3.3 V Oscillator
Crystek
C3391-4.096
32
1
U14
EEPROM, 1.8V, 256k
Microchip
24AA256-I/ST
33
2
Q1, Q2
MOSFET, P-Channel, 2.5V
Fairchild
Semiconductor
FDN302P
34
1
Q3
Enhancement Mode FET, N-Channel
Fairchild
Semiconductor
FDN337N
35
2
J5A, J6A
20 Pin SMT Plug
Samtec
TSM-110-01-L-DV-P
36
2
J5B, J6B
20 pin SMT Socket
Samtec
SSW-110-22-F-D-VS-K
37
1
J8A
10 Pin SMT Plug
Samtec
TSM-105-01-L-DV-P
38
1
J8B
10 pin SMT Socket
Samtec
SSW-105-22-F-D-VS-K
39
5
J1-J4, J10
Header Strip, 3-pin ( )
Samtec
TSW-103-07-L-S
Not Installed
1
J9
Header Strip, 6-pin ( )
Samtec
TSW-103-07-L-D
40
1
J7
Header Strip, 10-pin ( )
Samtec
TSW-105-07-L-D
41
1
N/A
ADS1282_82 EVM PCB
Texas
Instruments
6495106
42
2
D5, D6
Schottky Diode
Fairchild
BAT54
43
4
D1-D4
Schottky Diode, Stacked
Fairchild
BAT54S
44
2
D7, D8
5.1V, Zener Diode
On
Semiconductor
MMBZ5231BLT1G
45
1
S1
Switch, Mini Slide, DPDT
NKK
SS22SDP2
46
1
TP1
PCB Test Point, Large Loop,
Through-Hole
Keystone
Electronics
5011
47
9
N/A
Shorting Blocks
Samtec
SNT-100-BK-G-H
4.096MHz
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Ref Des
Description
Vendor
Part Number
ADS1282EVM and ADS1282EVM-PDK User's Guide
Copyright © 2009–2016, Texas Instruments Incorporated
27
1
2
3
4
REVISION HISTORY
REV
DVDD
ENGINEERING CHANGE NUMBER
APPROVED
C6
2K
J1
JPR-1X3
6
5
R2
150nF
+10V
RA2A
100K
AVDD
C4
7
1
8
1
2
3
D5
FRC_BAT54
0.1uF
U3
D
+10V
3
47
6
C3
22uF
C7
0.1uF
0.1uF
R4
0
-10V
C2
22uF
5
R5
0
D6
FRC_BAT54
C9
REF5050ID
RA1A
100K
1uF
U2
AVDD
C23
10uF
DVDD
C24
5
J5
C25
10uF
REF5025
47
C11 R18 1K
OPA1632
C12
-10V
R7
C16
C21
1nF C0G
22
17
AINP1
10uF
D2A
BAT54S
D1A
BAT54S
C17
10uF
ADS1282 - TSSOP-28
16
AINN2
15
1nF C0G R19
AVDD
1K
+10V
1nF C0G
D3B
BAT54S
R13
100K
1K
1
1K
+
6
OPA1632
C14
B
DVDD
R28
J10
JPR-1X3
D4B
BAT54S
M0
M1
MCLK
PDWN
PMODE
RESET
-10V
C22
1nF C0G
D3A
BAT54S
R11 47
C19
D4A
BAT54S
C20
10uF
DVDD
C34
9
PMODE 10
RESET 11
12
VCC A/B
Y
A
Y
B
G
GND
6
1
2
4
U12
1
3
OBCLK
R26
470K
SN74LVC2G157DCT
EOH
OUT
DVDD
4
2
VCC
GND
U10 +2.5V
+5V
1
IN
3
J6
A2
A1
INT
VCC
SDA
SCL
24
23
22
21
20
19
DVDD
0.1uF
PCA9535RGE
5
4
2
EN
C28
0.1uF
C30
10uF
B
JUMPER FUNCTIONS
J7
OUT
BYP
GND
1
3
5
7
9
2
4
6
8
10
DVDD
ADC AVDD
ADC AVSS
DIGITAL=3.3V
AGND
DGND
J4
5
2
These pins are shorted on the PCB.
+10V
FRC_FDN302P
3
5.1V
U13 -2.5V
-5VA
2
DAUGHTER-ANALOG
3
C33
1uF
IN
EN
OUT
BYP
GND
-10V
J8
1
3
5
7
9
D8
ONS_MMBZ5231BLT1
RefRef+
U14
J9
4
SN74LVC1G07DBV
4
JPR-1X3
RA3
100K
R14
100K
U9
3
2
5
SN74AHCT1G04DBV
+5V
U8
1
2
3
ADS1282
ADS1281
DVDD
Q1
+5V
+VA
+5VA
DGND
+1.8VD
+3.3VD
-VA
-5VA
AGND
VD1
+5VD
2
4
6
8
10
1
3
5
1
2
3
7
2
4
6
HEADER-3X2
A0
A1
A2
WP
DVDD
8
5
6
4
VCC
SDA
SCL
GND
C36
0.1uF
MCP_24AA256-I/ST
DAUGHTER-POWER
5
4
1
C29
0.1uF
TPS72325DBV
C31
10uF
J8A (TOP) = SAM_TSM-105-01-L-DV-P
J8B (BOTTOM) = SAM_SSW-105-22-F-D-VS
ti
+5V
TP1
GND
Q2
R15
100K
GND
Q3
DATA ACQUISITION PRODUCTS
HIGH-PERFORMANCE ANALOG DIVISION
SEMICONDUCTOR GROUP
6730 SOUTH TUCSON BLVD., TUCSON, AZ 85706 USA
FRC_FDN337N
FRC_FDN302P
ENGINEER RUSSELL ANDERSON
TITLE
ADS1281/82EVM
DRAWN BYRUSSELL ANDERSON
DOCUMENT CONTROL NO.6495107
SHEET 1
1
P06
P07
GND
P10
P11
P12
C5
C32
10nF C0G
CRY_C3391-4.096
JPR-2X5
J6A (TOP) = SAM_TSM-110-01-L-DV-P
J6B (BOTTOM) = SAM_SSW-110-22-F-D-VS-
SYNC 7
MFLAG 8
DVDD
TPS79225DBV
A
R25
470K
AVDD
C26
1uF
2
4
6
8
10
12
14
16
18
20
C
U11
+3.3V
1K
A0(+)
A1(+)
A2(+)
A3(+)
A4
A5
A6
A7
REFREF+
R27
100K
U7
R24
47K
1uF
8
5
3
7
10uF
1nF C0G R23
A0(-)
A1(-)
A2(-)
A3(-)
AGND
AGND
AGND
VCOM
AGND
AGND
DVDD
2
4
6
8
10
12
14
16
18
20
J5A (TOP) = SAM_TSM-110-01-L-DV-P
J5B (BOTTOM) = SAM_SSW-110-22-F-D-VS-K
3
2
1
JPR-1X3
C18
5 R10
2 47
4
J3
GPIO0
DGND
GPIO1
GPIO2
DGND
GPIO3
GPIO4
SCL
DGND
SDA
SERIALHDR
DVDD
100K
C27
10uF
3
+
VOCM
R21
JPR-1X3
MFLAG
10nF C0G
U5
8
AINP2
U6
ADS1281/82
C13 R22 1K
R20
ADS1281 - TSSOP-24
47
J2
CNTL
CLKX
CLKR
FSX
FSR
DX
DR
INT
TOUT
GPIO5
6
5
4
3
2
1
6
3
2
1
47
2
4
5
11
12
6
SCLK
DOUT
MOD/DIN
MFLAG
DGND
DGND
3
2
1
1K
+
-
AINN1
AVSS
RESET
PINMOD
PWDN
PHS/MCLK
DR1/M1
DR0/M0
DGND
1
18
20
24
25
23
7
8
9
27
VOCM
R17
5 R6
2 47
4
VREFP
-
VREFN
AVDD
DVDD
BYPAS
CLK
HPF/SYNC
DRDY
10uF
3
+
CAP+
CAP-
R12
100K
R9
U4
8
1K
SYNC
D2B
BAT54S
13
14
R16
D1B
BAT54S
C15
21
19
26
28
1
10
3
+10V
1nF C0G
C
1
3
5
7
9
11
13
15
17
19
R8
1uF
P05
P04
P03
P02
P01
P00
6
P13
P14
P15
P16
P17
A0
VIN
VOUT
TEMP
GND TRIM
13
14
15
16
17
18
2
3
4
C10
1uF
GPIO5
+10V
1
3
5
7
9
11
13
15
17
19
D
SYNC
MFLAG
PMODE
RESET
TOUT
C1
1uF
VIN
VOUT
TEMP
GND TRIM
D7
ONS_MMBZ5231BLT1
SW-DPDT
4
U1
C8
1uF
Ref-
OPA227
C35
10K
2
3
4
M0
M1
MCLK
PDWN
R3
6
R1
Ref+
S1
2
2
3
4
5
OF 1
SIZE B
DATE 21-AUG-2008
FILE
6
REV
A
A
Revision History
www.ti.com
Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from C Revision (May, 2011) to D Revision ..................................................................................................... Page
•
•
•
•
28
Changed function parameters on the J5.12 row in the J5: Serial Interface Pins table. .......................................... 4
Added External Wall-Adapter Power-Supply Requirements section. ............................................................. 11
Changed text of first paragraph in the Connecting the External Bipolar Supplies section. .................................... 12
Added low-power mode note in Controls Tab section. ............................................................................. 21
Revision History
SBAU144D – March 2009 – Revised May 2016
Submit Documentation Feedback
Copyright © 2009–2016, Texas Instruments Incorporated
STANDARD TERMS AND CONDITIONS FOR EVALUATION MODULES
1.
Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, or
documentation (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance with the terms and conditions set forth herein.
Acceptance of the EVM is expressly subject to the following terms and conditions.
1.1 EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms and conditions that accompany such Software
1.2 EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.
2
Limited Warranty and Related Remedies/Disclaimers:
2.1 These terms and conditions do not apply to Software. The warranty, if any, for Software is covered in the applicable Software
License Agreement.
2.2 TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for any defects that are caused by neglect, misuse or mistreatment
by an entity other than TI, including improper installation or testing, or for any EVMs that have been altered or modified in any
way by an entity other than TI. Moreover, TI shall not be liable for any defects that result from User's design, specifications or
instructions for such EVMs. Testing and other quality control techniques are used to the extent TI deems necessary or as
mandated by government requirements. TI does not test all parameters of each EVM.
2.3 If any EVM fails to conform to the warranty set forth above, TI's sole liability shall be at its option to repair or replace such EVM,
or credit User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the
warranty period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to
repair or replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall
be warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.
3
Regulatory Notices:
3.1 United States
3.1.1
Notice applicable to EVMs not FCC-Approved:
This kit is designed to allow product developers to evaluate electronic components, circuitry, or software associated with the kit
to determine whether to incorporate such items in a finished product and software developers to write software applications for
use with the end product. This kit is not a finished product and when assembled may not be resold or otherwise marketed unless
all required FCC equipment authorizations are first obtained. Operation is subject to the condition that this product not cause
harmful interference to licensed radio stations and that this product accept harmful interference. Unless the assembled kit is
designed to operate under part 15, part 18 or part 95 of this chapter, the operator of the kit must operate under the authority of
an FCC license holder or must secure an experimental authorization under part 5 of this chapter.
3.1.2
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant:
CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC Interference Statement for Class A EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
FCC Interference Statement for Class B EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
3.2 Canada
3.2.1
For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210
Concerning EVMs Including Radio Transmitters:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Concernant les EVMs avec appareils radio:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concerning EVMs Including Detachable Antennas:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur
3.3 Japan
3.3.1
Notice for EVMs delivered in Japan: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page 日本国内に
輸入される評価用キット、ボードについては、次のところをご覧ください。
http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page
3.3.2
Notice for Users of EVMs Considered “Radio Frequency Products” in Japan: EVMs entering Japan may not be certified
by TI as conforming to Technical Regulations of Radio Law of Japan.
If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required by Radio Law of
Japan to follow the instructions below with respect to EVMs:
1.
2.
3.
Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,
Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or
Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.
SPACER
SPACER
SPACER
SPACER
SPACER
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて
いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの
措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用
いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ
ンスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
3.3.3
Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧くださ
い。http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
SPACER
4
EVM Use Restrictions and Warnings:
4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT
LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling
or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.
4.3 Safety-Related Warnings and Restrictions:
4.3.1
User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.
4.3.2
EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.
4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,
state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.
5.
Accuracy of Information: To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate
as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
6.
Disclaimers:
6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY WRITTEN DESIGN MATERIALS PROVIDED WITH THE EVM (AND THE
DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL FAULTS." TI DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY
THIRD PARTY PATENTS, COPYRIGHTS, TRADE SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.
6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS AND
CONDITIONS SHALL BE CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY
OTHER INDUSTRIAL OR INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD
PARTY, TO USE THE EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY
INVENTION, DISCOVERY OR IMPROVEMENT MADE, CONCEIVED OR ACQUIRED PRIOR TO OR AFTER DELIVERY OF
THE EVM.
7.
USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS. USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS
LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS AND CONDITIONS. THIS OBLIGATION
SHALL APPLY WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY
OTHER LEGAL THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.
8.
Limitations on Damages and Liability:
8.1 General Limitations. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,
INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS ANDCONDITIONS OR THE USE OF THE EVMS PROVIDED HEREUNDER, REGARDLESS OF WHETHER TI HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED
TO, COST OF REMOVAL OR REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES, RETESTING, OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS,
LOSS OF SAVINGS, LOSS OF USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL
BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED.
8.2 Specific Limitations. IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY WARRANTY OR OTHER OBLIGATION
ARISING OUT OF OR IN CONNECTION WITH THESE TERMS AND CONDITIONS, OR ANY USE OF ANY TI EVM
PROVIDED HEREUNDER, EXCEED THE TOTAL AMOUNT PAID TO TI FOR THE PARTICULAR UNITS SOLD UNDER
THESE TERMS AND CONDITIONS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE CLAIMED. THE EXISTENCE
OF MORE THAN ONE CLAIM AGAINST THE PARTICULAR UNITS SOLD TO USER UNDER THESE TERMS AND
CONDITIONS SHALL NOT ENLARGE OR EXTEND THIS LIMIT.
9.
Return Policy. Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)
will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.
10. Governing Law: These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,
without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated
spacer
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265