0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BQ27531YZFT-G1

BQ27531YZFT-G1

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    UFBGA15

  • 描述:

    IC BATT FUEL GAUGE LIION 15DSBGA

  • 数据手册
  • 价格&库存
BQ27531YZFT-G1 数据手册
Product Folder Sample & Buy Support & Community Tools & Software Technical Documents Reference Design bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 bq27531-G1 Battery Management Unit Impedance Track™ Fuel Gauge With MaxLife™ Technology for Use With the bq2419x Charger Controller 1 Features 3 • The Texas Instruments bq27531-G1 system-side LiIon Battery Management Unit is a microcontroller peripheral that provides Impedance Track fuel gauging and charging control for single-cell Li-Ion battery packs. The device requires little system microcontroller firmware development. Together with the bq2419x Single-Cell Switched-Mode Charger, the bq27531-G1 manages an embedded battery (nonremovable) or a removable battery pack. 1 • • • • • • • • Battery Fuel Gauge and Charger Controller for 1Cell Li-Ion Applications Resides on System Main Board Battery Fuel Gauge Based on Patented Impedance Track™ Technology – Models the Battery Discharge Curve for Accurate Time-to-Empty Predictions – Automatically Adjusts for Battery Aging, Battery Self-Discharge, and Temperature/Rate Inefficiencies – Low-Value Sense Resistor (5 mΩ to 20 mΩ) Battery Charger Controller With Customizable Charge Profiles – Configurable Charge Voltage and Current Based on Temperature – Optional State of Health (SoH) and MultilevelBased Charge Profiles Host-Free Autonomous Battery Management System – Reduced Software Overhead Allows for Easy Portability Across Platforms and Shorter OEM Design Cycles – Higher Safety and Security Intelligent Charging—Customized and Adaptive Charging Profiles – Charger Control Based on SoH – Temperature Level Charging (TLC) Battery Charger Controller for bq2419x Single-Cell Switched-Mode Battery Charger – Stand-Alone Charging Solution – SHIP Mode Capability 400-kHz I2C Interface for Connection to System Microcontroller Port In a 15-Pin NanoFree™ Packaging Description The bq27531-G1 uses the patented Impedance Track algorithm for fuel gauging, and provides information such as remaining battery capacity (mAh), state-ofcharge (%), run time to empty (minimum), battery voltage (mV), temperature (°C), and state of health (%). Battery fuel gauging with the bq27531-G1 requires only PACK+ (P+), PACK– (P–), and Thermistor (T) connections to a removable battery pack or embedded battery circuit. The CSP option is a 15-pin package in the dimensions of 2.61 mm × 1.96 mm with a 0.5-mm lead pitch, which is ideal for spaceconstrained applications. Device Information(1) PART NUMBER PACKAGE bq27531-G1 BODY SIZE (NOM) DSBGA (15) 2.61 mm × 1.96 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. Simplified Schematic 5V USB or AC Adapter SW VBUS SYSTEM LOAD SYS BQ2419x BAT PGND I2C 2 • • • • Applications Smart Phones, Feature Phones, and Tablets Digital Still and Video Cameras Handheld Terminals MP3 or Multimedia Players Single Cell Li-Ion Battery Pack Voltage Sense I2C Application Processor Temp Sense P+ T PROTECTION IC BQ27531-G1 SOCINT P- FETs Current Sense 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com Table of Contents 1 2 3 4 5 6 7 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Device Options....................................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 2 3 3 4 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 4 4 4 4 5 5 5 5 5 Absolute Maximum Ratings ...................................... ESD Ratings.............................................................. Recommended Operating Conditions....................... Thermal Information .................................................. Electrical Characteristics: Supply Current................. Digital Input and Output DC Characteristics ............. Power-On Reset........................................................ 2.5-V LDO Regulator ................................................ Internal Clock Oscillators .......................................... ADC (Temperature and Cell Measurement) Characteristics ........................................................... 7.11 Integrating ADC (Coulomb Counter) Characteristics ........................................................... 7.12 Data Flash Memory Characteristics........................ 7.13 I2C-Compatible Interface Communication Timing Characteristics ........................................................... 6 6 6 7 7.14 Typical Characteristics ............................................ 8 8 Detailed Description .............................................. 9 8.1 8.2 8.3 8.4 8.5 9 Overview ................................................................... 9 Functional Block Diagram ....................................... 10 Feature Description................................................. 11 Device Functional Modes........................................ 12 Programming........................................................... 16 Application and Implementation ........................ 21 9.1 Application Information............................................ 21 9.2 Typical Application ................................................. 21 10 Power Supply Recommendations ..................... 26 10.1 Power Supply Decoupling ..................................... 26 11 Layout................................................................... 26 11.1 Layout Guidelines ................................................. 26 11.2 Layout Example .................................................... 27 12 Device and Documentation Support ................. 28 12.1 12.2 12.3 12.4 12.5 Documentation Support ........................................ Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 28 28 28 28 28 13 Mechanical, Packaging, and Orderable Information ........................................................... 28 4 Revision History Changes from Revision B (September 2015) to Revision C • Page Changed ESD Ratings ........................................................................................................................................................... 4 Changes from Revision A (June 2015) to Revision B Page • Changed a Pin Functions description to correct the TRM link ............................................................................................... 3 • Changed Figure 6 ................................................................................................................................................................ 13 • Added Figure 7 .................................................................................................................................................................... 14 2 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 5 Device Options PART NUMBER bq27531YZFR-G1 bq27531YZFT-G1 FIRMWARE VERSION COMMUNICATION FORMAT 1.02 (0x0102) I2C 6 Pin Configuration and Functions YZF Package 15-Pin DSBGA (TOP VIEW) B3 C3 D3 E3 E3 D3 C3 B3 A3 A2 B2 C2 D2 E2 E2 D2 C2 B2 A2 A1 B1 C1 D1 E1 E1 D1 C1 B1 A1 A3 E (BOTTOM VIEW) xx xx Pin A1 Index Area D DIM MIN TYP MAX D 2580 2610 2640 E 1926 1956 1986 UNITS m Pin Functions PIN NAME NO. I/O (1) DESCRIPTION BAT E2 I BI/TOUT E3 I/O Battery insertion detection input. Power pin for pack thermistor network. Thermistor multiplexer control pin. Use with pullup resistor >1 MΩ (1.8 MΩ typical). BSDA C3 I/O Battery Charger data line for chipset communication. Push-pull output. BSCL B2 O Battery Charger clock output line for chipset communication. Push-pull output. CE D2 I Chip Enable. Internal LDO is disconnected from REGIN when driven low. Note: CE has an internal ESD protection diode connected to REGIN. Recommend maintaining VCE ≤ VREGIN under all conditions. REGIN E1 P Regulator input. Decouple with 0.1-μF ceramic capacitor to Vss. SCL A3 I Slave I2C serial communications clock input line for communication with system (Master). Open-drain I/O. Use with 10-kΩ pullup resistor (typical). SDA B3 I/O Slave I2C serial communications data line for communication with system (Master). Open-drain I/O. Use with 10-kΩ pullup resistor (typical). SOC_INT A2 I/O SOC state interrupts output. Generates a pulse as described in the bq27531-G1 Technical Reference Manual (SLUUA96). Open-drain output. SRN B1 IA Analog input pin connected to the internal coulomb counter where SRN is nearest the Vss connection. Connect to 5mΩ to 20-mΩ sense resistor. SRP A1 IA Analog input pin connected to the internal coulomb counter where SRP is nearest the PACK– connection. Connect to 5-mΩ to 20-mΩ sense resistor. TS D3 IA Pack thermistor voltage sense (use 103AT-type thermistor). ADC input. VCC D1 P Regulator output and bq27531-G1 power. Decouple with 1-μF ceramic capacitor to Vss. VSS C1, C2 P Device ground (1) Cell voltage measurement input. ADC input. Recommend 4.8 V maximum for conversion accuracy. I/O = Digital input/output, IA = Analog input, P = Power connection Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 3 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 7 Specifications 7.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted) (1) MIN MAX –0.3 5.5 UNIT VREGIN Regulator input VCE CE input pin –0.3 VREGIN + 0.3 V VCC Supply voltage –0.3 2.75 V VIOD Open-drain I/O pins (SDA, SCL, SOC_INT) –0.3 5.5 V –0.3 5.5 –0.3 6.0 V (2) VBAT BAT input pin VI Input voltage to all other pins (BI/TOUT, TS, SRP, SRN, BSDA, BSCL) –0.3 VCC + 0.3 V TA Operating free-air temperature –40 85 °C (1) (2) –0.3 6.0 V (2) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Condition not to exceed 100 hours at 25°C lifetime. 7.2 ESD Ratings VALUE Electrostatic discharge V(ESD) (1) (2) Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, BAT pin (1) ±1500 Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001), All other pins (1) ±2000 Charged device model (CDM), per JEDEC specification JESD22-C101 (2) ±250 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. 7.3 Recommended Operating Conditions TA = –40°C to 85°C, VREGIN = VBAT = 3.6 V (unless otherwise noted) MIN No operating restrictions VREGIN Supply voltage CREGIN External input capacitor for internal LDO between REGIN and VSS CLDO25 External output capacitor for internal LDO between VCC and VSS tPUCD Power-up communication delay No flash writes Nominal capacitor values specified. Recommend a 5% ceramic X5R type capacitor located close to the device. NOM MAX 2.8 4.5 2.45 2.8 UNIT V 0.1 μF 1 μF 250 ms 0.47 7.4 Thermal Information bq27531-G1 THERMAL METRIC (1) YZF [DSBGA] UNIT 15 PINS RθJA Junction-to-ambient thermal resistance 70 °C/W RθJC(top) Junction-to-case(top) thermal resistance 17 °C/W RθJB Junction-to-board thermal resistance 20 °C/W ψJT Junction-to-top characterization parameter 1 °C/W ψJB Junction-to-board characterization parameter 18 °C/W RθJC(bot) Junction-to-case(bottom) thermal resistance N/A °C/W (1) 4 For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 7.5 Electrical Characteristics: Supply Current TA = 25°C and VREGIN = VBAT = 3.6 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ICC (1) NORMAL operating mode current Fuel gauge in NORMAL mode ILOAD > Sleep current 118 μA ISLP+ (1) SLEEP+ operating mode current Fuel gauge in SLEEP+ mode ILOAD < Sleep current 62 μA ISLP (1) Low-power storage mode current Fuel gauge in SLEEP mode ILOAD < Sleep current 23 μA IHIB (1) HIBERNATE operating mode current Fuel gauge in HIBERNATE mode ILOAD < Hibernate current 8 μA (1) Specified by design. Not production tested. 7.6 Digital Input and Output DC Characteristics TA = –40°C to 85°C, typical values at TA = 25°C and VREGIN = 3.6 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN VOL Output voltage, low (SCL, SDA, SOC_INT, BSDA, BSCL) IOL = 3 mA VOH(PP) Output voltage, high (BSDA, BSCL) IOH = –1 mA VCC – 0.5 VOH(OD) Output voltage, high (SDA, SCL, SOC_INT) External pullup resistor connected to VCC VCC – 0.5 Input voltage, low (SDA, SCL) VIL Input voltage, low (BI/TOUT) Input voltage, high (SDA, SCL) VIH Input voltage, high (BI/TOUT) VIL(CE) Input voltage, low (CE) VIH(CE) Input voltage, high (CE) Ilkg BAT INSERT CHECK mode active (1) (1) TYP MAX 0.4 VREGIN = 2.8 V to 4.5 V V V –0.3 0.6 –0.3 0.6 1.2 BAT INSERT CHECK mode active UNIT 1.2 VCC + 0.3 0.8 2.65 Input leakage current (I/O pins) 0.3 V V V μA Specified by design. Not production tested. 7.7 Power-On Reset TA = –40°C to 85°C, typical values at TA = 25°C and VREGIN = 3.6 V (unless otherwise noted) PARAMETER VIT+ Positive-going battery voltage input at VCC VHYS Power-on reset hysteresis TEST CONDITIONS MIN TYP MAX UNIT 2.05 2.15 2.20 V 115 mV 7.8 2.5-V LDO Regulator TA = –40°C to 85°C, CLDO25 = 1 μF, VREGIN = 3.6 V (unless otherwise noted) PARAMETER VREG25 (1) Regulator output voltage (VCC) TEST CONDITION MIN TYP MAX 2.8 V ≤ VREGIN ≤ 4.5 V, IOUT ≤ 16 mA (1) 2.3 2.5 2.6 2.45 V ≤ VREGIN < 2.8 V (low battery), IOUT ≤ 3mA 2.3 UNIT V LDO output current, IOUT, is the total load current. LDO regulator must be used to power internal fuel gauge only. 7.9 Internal Clock Oscillators TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT fOSC High-frequency oscillator 8.389 MHz fLOSC Low-frequency oscillator 32.768 kHz Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 5 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 7.10 ADC (Temperature and Cell Measurement) Characteristics TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX VADC1 Input voltage (TS) VSS – 0.125 2 VADC2 Input voltage (BAT) VSS – 0.125 5 VIN(ADC) Input voltage GTEMP Internal temperature sensor voltage gain tADC_CONV Conversion time 0.05 Resolution VOS(ADC) (1) Effective input resistance (TS) ZADC2 (1) Effective input resistance (BAT) (1) Ilkg(ADC) (1) V ms 15 bits mV 8 MΩ 8 bq27531-G1 measuring cell voltage V 125 1 bq27531-G1 not measuring cell voltage V mV/°C 14 Input offset ZADC1 1 –2 UNIT MΩ 100 kΩ Input leakage current 0.3 μA Specified by design. Not tested in production. 7.11 Integrating ADC (Coulomb Counter) Characteristics TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS VSR Input voltage, V(SRP) and V(SRN) VSR = V(SRP) – V(SRN) tSR_CONV Conversion time Single conversion Resolution VOS(SR) Input offset INL Integral nonlinearity error ZIN(SR) (1) (1) TYP –0.125 MAX UNIT 0.125 V 1 s 14 15 bits ±0.034% FSR μV 10 ±0.007% Effective input resistance Ilkg(SR) (1) MIN 2.5 MΩ Input leakage current 0.3 μA Specified by design. Not tested in production. 7.12 Data Flash Memory Characteristics TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER tDR (1) TEST CONDITIONS Data retention Flash-programming write cycles (1) tWORDPROG (1) ICCPROG (1) tDFERASE tIFERASE (1) tPGERASE (1) 6 (1) (1) MIN TYP MAX UNIT 10 Years 20000 Cycles Word programming time Flash-write supply current 5 2 ms 10 mA Data flash master erase time 200 ms Instruction flash master erase time 200 ms 20 ms Flash page erase time Specified by design. Not production tested. Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 7.13 I2C-Compatible Interface Communication Timing Characteristics TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER MIN NOM MAX UNIT tr SCL/SDA rise time 300 ns tf SCL/SDA fall time 300 ns tw(H) SCL pulse duration (high) 600 ns tw(L) SCL pulse duration (low) 1.3 μs tsu(STA) Setup for repeated start 600 ns td(STA) Start to first falling edge of SCL 600 ns tsu(DAT) Data setup time 100 ns th(DAT) Data hold time tsu(STOP) Setup time for stop t(BUF) Bus free time between stop and start fSCL (1) Clock frequency 0 ns 600 ns 66 μs (1) 400 kHz If the clock frequency (fSCL) is > 100 kHz, use 1-byte write commands for proper operation. All other transactions types are supported at 400 kHz. (See I2C Interface and I2C Command Waiting Time). Figure 1. I2C-Compatible Interface Timing Diagrams Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 7 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 7.14 Typical Characteristics 8.8 VREGIN = 2.7 V VREGIN = 4.5 V 2.6 fOSC - High Frequency Oscillator (MHz) VREG25 - Regulator Output Voltage (V) 2.65 2.55 2.5 2.45 2.4 2.35 8.7 8.6 8.5 8.4 8.3 8.2 8.1 8 -40 Temperature (qC) -20 0 20 40 Temperature (qC) D001 34 5 33.5 4 33 32.5 32 31.5 31 30.5 30 -40 -20 0 20 40 Temperature (qC) 60 80 100 8 100 D002 3 2 1 0 -1 -2 -3 -4 -5 -30 -20 D003 Figure 4. Low-Frequency Oscillator Frequency vs Temperature 80 Figure 3. High-Frequency Oscillator Frequency vs Temperature Reported Temperature Error (qC) fLOSC - Low Frequency Oscillator (kHz) Figure 2. Regulator Output Voltage vs Temperature 60 -10 0 10 20 30 Temperature (qC) 40 50 60 D004 Figure 5. Reported Internal Temperature Measurement vs Temperature Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 8 Detailed Description 8.1 Overview The fuel gauge accurately predicts the battery capacity and other operational characteristics of a single, Libased, rechargeable cell. It can be interrogated by a system processor to provide cell information, such as remaining capacity and state-of-charge (SOC) as well as SOC interrupt signal to the host. The fuel gauge can control a bq2419x Charger IC without the intervention from an application system processor. Using the bq27531-G1 and bq2419x chipset, batteries can be charged with the typical constant-current, constant-voltage (CCCV) profile or charged using a Multi-Level Charging (MLC) algorithm. NOTE Formatting conventions used in this document: Commands: italics with parentheses and no breaking spaces, for example, Control() Data flash: italics, bold, and breaking spaces, for example, Design Capacity Register bits and flags: brackets and italics, for example, [TDA] Data flash bits: brackets, italics and bold, for example, [LED1] Modes and states: ALL CAPITALS, for example, UNSEALED mode Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 9 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 8.2 Functional Block Diagram REGIN LDO POR 2.5 V VCC HFO BAT CC HFO SRN LFO HFO/128 4R HFO/128 SRP MUX ADC R Wake Comparator TS Internal Temp Sensor BI/TOUT HFO/4 SDA SOCINT 22 I2C Slave Engine Instruction ROM 22 CPU VSS SCL I/O Controller Instruction FLASH BSDA 8 Wake and Watchdog Timer 10 GP Timer and PWM 8 I2C Master Engine BSCL Data SRAM Data FLASH Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 8.3 Feature Description Information is accessed through a series of commands, called Standard Commands. Further capabilities are provided by the additional Extended Commands set. Both sets of commands, indicated by the general format Command(), are used to read and write information contained within the control and status registers, as well as its data flash locations. Commands are sent from system to gauge using the I2C serial communications engine, and can be executed during application development, pack manufacture, or end-equipment operation. Cell information is stored in nonvolatile flash memory. Many of these data flash locations are accessible during application development. They cannot, generally, be accessed directly during end-equipment operation. Access to these locations is achieved by either use of the companion evaluation software, through individual commands, or through a sequence of data-flash access commands. To access a desired data flash location, the correct data flash subclass and offset must be known. The key to the high-accuracy gas gauging prediction is the TI proprietary Impedance Track algorithm. This algorithm uses cell measurements, characteristics, and properties to create SOC predictions that can achieve less than 1% error across a wide variety of operating conditions and over the lifetime of the battery. The fuel gauge measures the charging and discharging of the battery by monitoring the voltage across a smallvalue series sense resistor (5 to 20 mΩ, typical) located between the system VSS and the battery PACK– terminal. When a cell is attached to the fuel gauge, cell impedance is computed, based on cell current, cell opencircuit voltage (OCV), and cell voltage under loading conditions. The external temperature sensing is optimized with the use of a high-accuracy negative temperature coefficient (NTC) thermistor with R25 = 10.0 kΩ ±1%, B25/85 = 3435 K ±1% (such as Semitec NTC 103AT). The fuel gauge can also be configured to use its internal temperature sensor. When an external thermistor is used, a 18.2-kΩ pullup resistor between the BI/TOUT and TS pins is also required. The fuel gauge uses temperature to monitor the battery-pack environment, which is used for fuel gauging and cell protection functionality. To minimize power consumption, the fuel gauge has different power modes: NORMAL, SLEEP, SLEEP+, HIBERNATE, and BAT INSERT CHECK. The fuel gauge passes automatically between these modes, depending upon the occurrence of specific events, though a system processor can initiate some of these modes directly. For complete operational details, see the bq27531-G1 Technical Reference Manual (SLUUA96). 8.3.1 Functional Description The fuel gauge measures the cell voltage, temperature, and current to determine battery SOC. The fuel gauge monitors the charging and discharging of the battery by sensing the voltage across a small-value resistor (5 mΩ to 20 mΩ, typical) between the SRP and SRN pins and in series with the cell. By integrating charge passing through the battery, the battery SOC is adjusted during battery charge or discharge. The total battery capacity is found by comparing states of charge before and after applying the load with the amount of charge passed. When an application load is applied, the impedance of the cell is measured by comparing the OCV obtained from a predefined function for present SOC with the measured voltage under load. Measurements of OCV and charge integration determine chemical SOC and chemical capacity (Qmax). The initial Qmax values are taken from a cell manufacturer's data sheet multiplied by the number of parallel cells. It is also used for the value in Design Capacity. The fuel gauge acquires and updates the battery-impedance profile during normal battery usage. It uses this profile, along with SOC and the Qmax value, to determine FullChargeCapacity() and StateOfCharge(), specifically for the present load and temperature. FullChargeCapacity() is reported as capacity available from a fully-charged battery under the present load and temperature until Voltage() reaches the Terminate Voltage. NominalAvailableCapacity() and FullAvailableCapacity() are the uncompensated (no or light load) versions of RemainingCapacity() and FullChargeCapacity(), respectively. The fuel gauge has two flags accessed by the Flags() function that warn when the battery SOC has fallen to critical levels. When RemainingCapacity() falls below the first capacity threshold as specified in SOC1 Set Threshold, the [SOC1] (State of Charge Initial) flag is set. The flag is cleared once RemainingCapacity() rises above SOC1 Clear Threshold. When the voltage is discharged to Terminate Voltage, the SOC will be set to 0. Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 11 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 8.4 Device Functional Modes 8.4.1 Power Modes The fuel gauge has different power modes: • BAT INSERT CHECK: The BAT INSERT CHECK mode is a powered-up, but low-power halted, state where the fuel gauge resides when no battery is inserted into the system. • NORMAL: In NORMAL mode, the fuel gauge is fully powered and can execute any allowable task. • SLEEP: In SLEEP mode, the fuel gauge turns off the high-frequency oscillator and exists in a reduced- power state, periodically taking measurements and performing calculations. • SLEEP+: In SLEEP+ mode, both low-frequency and high-frequency oscillators are active. Although the SLEEP+ mode has higher current consumption than the SLEEP mode, it is also a reduced power mode. • HIBERNATE: In HIBERNATE mode, the fuel gauge is in a low power state, but can be woken up by communication or certain I/O activity. The relationship between these modes is shown in Figure 6 and Figure 7. 8.4.1.1 BAT INSERT CHECK Mode This mode is a halted-CPU state that occurs when an adapter, or other power source, is present to power the fuel gauge (and system), yet no battery has been detected. When battery insertion is detected, a series of initialization activities begin, which include: OCV measurement, setting the Flags() [BAT_DET] bit, and selecting the appropriate battery profiles. Some commands, issued by a system processor, can be processed while the fuel gauge is halted in this mode. The gauge wakes up to process the command, then returns to the halted state awaiting battery insertion. 8.4.1.2 NORMAL Mode The fuel gauge is in NORMAL mode when not in any other power mode. During this mode, AverageCurrent() , Voltage() , and Temperature() measurements are taken, and the interface data set is updated. Decisions to change states are also made. This mode is exited by activating a different power mode. Because the gauge consumes the most power in NORMAL mode, the Impedance Track algorithm minimizes the time the fuel gauge remains in this mode. 8.4.1.3 SLEEP Mode SLEEP mode is entered automatically if the feature is enabled (Op Config [SLEEP] = 1) and AverageCurrent() is below the programmable level Sleep Current. Once entry into SLEEP mode has been qualified, but prior to entering it, the fuel gauge performs a coulomb counter autocalibration to minimize offset. During SLEEP mode, the fuel gauge periodically takes data measurements and updates its data set. However, a majority of its time is spent in an idle condition. The fuel gauge exits SLEEP mode if any entry condition is broken, specifically when: • AverageCurrent() rises above Sleep Current, or • A current in excess of IWAKE through RSENSE is detected. In the event that a battery is removed from the system while a charger is present (and powering the gauge), Impedance Track updates are not necessary. Hence, the fuel gauge enters a state that checks for battery insertion and does not continue executing the Impedance Track algorithm. 12 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 Device Functional Modes (continued) Exit From HIBERNATE Battery Removed POR BAT INSERT CHECK Exit From HIBERNATE Communication Activity AND Comm address is for bq27531 bq27531 clears CONTROL_STATUS [HIBERNATE] = 0 Recommend Host also set CONTROL_STATUS [HEBERNATE] = 0 Check for battery insertion from HALT state. No gauging Entry To NORMAL Flags [BAT_DET] = 1 Exit From NORMAL Flags [BAT_DET] = 0 NORMAL Entry To SLEEP+ Operation Configuration [SLEEP] = 1 AND CONTROL_STAUS [SNOOZE] = 1] AND Ι AverageCurrent ( ) Ι < Sleep Current Flags [BAT_DET] = 0 Fuel gauging and data updated every second Exit From SLEEP Flags [BAT_DET] = 0 Exit From SLEEP Ι AverageCurrent ( ) Ι > Sleep Current OR Current is detected above Ι WAKE Exit From SLEEP+ Any communication to the gauge OR Ι AverageCurrent ( ) Ι > Sleep Current OR Current is detected above Ι WAKE SLEEP+ Entry To SLEEP+ Operation Configuration [SLEEP] = 1 Fuel gauging and data updated every 20 seconds. Both LFO and HFO are ON. AND Ι AverageCurrent ( ) Ι < Sleep Current AND CONTROL_STAUS [SNOOZE] = 0 Entry to SLEEP+ CONTROL_STATUS [SNOOZE] = 1 Entry to SLEEP CONTROL_STATUS [SNOOZE] = 0 SLEEP Fuel gauging and data updated every 20 seconds. (LFO ON and HFO OFF) Exit From WAIT_HIBERNATE Host must set CONTROL_STATUS [HIBERNATE] = 0 AND VCELL < Hibernate Voltage To WAIT_HIBERNATE System Sleep Exit From SLEEP Host has set CONTROL_STATUS [HIBERNATE] = 1 OR VCELL < Hibernate Voltage Figure 6. Power Mode Diagram—System Sleep Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 13 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com Device Functional Modes (continued) POR Exit From HIBERNATE Battery Removed Exit From HIBERNATE Communication Activity AND Comm address is for bq27531 bq27531 clears CONTROL_STATUS [HIBERNATE] = 0 Recommend Host also set CONTROL_STATUS [HEBERNATE] = 0 Exit From SLEEP Flags [BAT_DET] = 0 BAT INSERT CHECK Check for battery insertion from HALT state. No gauging Entry To NORMAL Flags [BAT_DET] = 1 Flags [BAT_DET] = 0 Exit From NORMAL Flags [BAT_DET] = 0 NORMAL Fuel gauging and data updated every second. HIBERNATE Disable all bq27531 subcircuits. Wakeup From HIBERNATE Communication Activity AND Comm address is not for bq27531 Exit From WAIT_HIBERNATE Host must set CONTROL_STATUS [HIBERNATE] = 0 AND VCELL < Hibernate Voltage To SLEEP WAIT_HIBERNATE Exit From WAIT_HIBERNATE Cell relaxed AND Ι AverageCurrent () Ι < Hibernate Current OR Cell relaxed AND VCELL < Hibernate Voltage Fuel gauging and data updated every 20 seconds. Exit From SLEEP Host has set CONTROL_STATUS [HIBERNATE] = 1 OR VCELL < Hibernate Voltage System Shutdown Figure 7. Power Mode Diagram—System Shutdown 14 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 Device Functional Modes (continued) 8.4.2 SLEEP+ Mode Compared to the SLEEP mode, SLEEP+ mode has the high-frequency oscillator in operation. The communication delay could be eliminated. The SLEEP+ mode is entered automatically if the feature is enabled (CONTROL_STATUS [SNOOZE] = 1) and AverageCurrent() is below the programmable level Sleep Current. During SLEEP+ mode, the fuel gauge periodically takes data measurements and updates its data set. However, a majority of its time is spent in an idle condition. The fuel gauge exits SLEEP+ mode if any entry condition is broken, specifically when: • Any communication activity with the gauge, or • AverageCurrent() rises above Sleep Current , or • A current in excess of IWAKE through RSENSE is detected. 8.4.3 HIBERNATE Mode HIBERNATE mode should be used when the system equipment needs to enter a low-power state, and minimal gauge power consumption is required. This mode is ideal when system equipment is set to its own HIBERNATE, SHUTDOWN, or OFF mode. Before the fuel gauge can enter HIBERNATE mode, the system must set the CONTROL_STATUS [HIBERNATE] bit. The gauge waits to enter HIBERNATE mode until it has taken a valid OCV measurement and the magnitude of the average cell current has fallen below Hibernate Current. The gauge can also enter HIBERNATE mode if the cell voltage falls below Hibernate Voltage and a valid OCV measurement has been taken. The gauge remains in HIBERNATE mode until the system issues a direct I 2 C command to the gauge or a POR occurs. Any I 2 C communication that is not directed to the gauge does not wake the gauge. It is the responsibility of the system to wake the fuel gauge after it has gone into HIBERNATE mode. After waking, the gauge can proceed with the initialization of the battery information (OCV, profile selection, and so forth). Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 15 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 8.5 Programming 8.5.1 Data Commands 8.5.1.1 Standard Data Commands The bq27531-G1 uses a series of 2-byte standard commands to enable system reading and writing of battery information. Each standard command has an associated command-code pair, as indicated in Table 1. Because each command consists of two bytes of data, two consecutive I2C transmissions must be executed both to initiate the command function, and to read or write the corresponding two bytes of data. Additional details are found in the bq27531-G1 Technical Reference Manual (SLUUA96). Table 1. Standard Commands COMMAND CODE UNIT SEALED ACCESS UNSEALED ACCESS Control() 0x00 and 0x01 NA R/W R/W AtRate() 0x02 and 0x03 mA R/W R/W AtRateTimeToEmpty() 0x04 and 0x05 Minutes R R/W Temperature() 0x06 and 0x07 0.1 K R/W R/W NAME Voltage() 0x08 and 0x09 mV R R/W Flags() 0x0A and 0x0B Hex R R/W NominalAvailableCapacity() 0x0C and 0x0D mAh R R/W FullAvailableCapacity() 0x0E and 0x0F mAh R R/W RemainingCapacity() 0x10 and 0x11 mAh R R/W FullChargeCapacity() 0x12 and 0x13 mAh R R/W AverageCurrent() 0x14 and 0x15 mA R R/W TimeToEmpty() 0x16 and 0x17 Minutes R R/W RemainingCapacityUnfiltered() 0x18 and 0x19 mAh R R/W StandbyCurrent() 0x1A and 0x1B mA R R/W RemainingCapacityFiltered() 0x1C and 0x1D mAh R R/W ProgChargingCurrent() 0x1E and 0x1F mA R (1) R (1) (1) R (1) ProgChargingVoltage() 0x20 and 0x21 mV FullChargeCapacityUnfiltered() 0x22 and 0x23 mAh R R/W AveragePower() 0x24 and 0x25 mW R R/W FullChargeCapacityFiltered() 0x26 and 0x27 mAh R R/W StateOfHealth() 0x28 and 0x29 %/num R R/W CycleCount() 0x2A and 0x2B Counters R R/W StateOfCharge() 0x2C and 0x2D % R R/W TrueSOC() 0x2E and 0x2F % R R/W InstantaneousCurrentReading() 0x30 and 0x31 mA R R/W InternalTemperature() 0x32 and 0x33 0.1 K R R/W ChargingLevel() 0x34 and 0x35 Num R R LevelTaperCurrent() 0x6E and 0x6F mA R R CalcChargingCurrent() 0x70 and 0x71 mA R R CalcChargingVoltage() 0x72 and 0x73 V R R (1) 16 R Only writeable when Charger Options [BYPASS] is set. Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com 8.5.1.1.1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 Control(): 0x00/0x01 Issuing a Control() command requires a subsequent 2-byte subcommand. These additional bytes specify the particular control function desired. The Control() command allows the system to control specific features of the bq27531-G1 during normal operation and additional features when the device is in different access modes, as described in Table 2. Additional details are found in the bq27531-G1 Technical Reference Manual (SLUUA96). Table 2. Control() Subcommands CNTL DATA SEALED ACCESS CONTROL_STATUS 0x0000 Yes Reports the status of hibernate, IT, and so forth DEVICE_TYPE 0x0001 Yes Reports the device type (for example, 0x0531 for bq27531) FW_VERSION 0x0002 Yes Reports the firmware version on the device type HW_VERSION 0x0003 Yes Reports the hardware version of the device type PREV_MACWRITE 0x0007 Yes Returns previous MAC subcommand code CHEM_ID 0x0008 Yes Reports the chemical identifier of the Impedance Track configuration BOARD_OFFSET 0x0009 No Forces the device to measure and store the board offset CC_OFFSET 0x000a No Forces the device to measure the internal CC offset CC_OFFSET_SAVE 0x000b No Forces the device to store the internal CC offset OCV_CMD 0x000c Yes Request the gauge to take a OCV measurement BAT_INSERT 0x000d Yes Forces the BAT_DET bit set when the [BIE] bit is 0 BAT_REMOVE 0x000e Yes Forces the BAT_DET bit clear when the [BIE] bit is 0 SET_HIBERNATE 0x0011 Yes Forces CONTROL_STATUS [HIBERNATE] to 1 CLEAR_HIBERNATE 0x0012 Yes Forces CONTROL_STATUS [HIBERNATE] to 0 SET_SLEEP+ 0x0013 Yes Forces CONTROL_STATUS [SNOOZE] to 1 CLEAR_SLEEP+ 0x0014 Yes Forces CONTROL_STATUS [SNOOZE] to 0 OTG_ENABLE 0x0015 Yes Commands the bq2419x into USB On The Go mode OTG_DISABLE 0x0016 Yes Disables OTG mode at the bq2419x DIV_CUR_ENABLE 0x0017 Yes Makes the programmed charge current to be half of what is calculated by the gauge charging algorithm. CHG_ENABLE 0x001A Yes Enable charger. Charge will continue as dictated by gauge charging algorithm. CHG_DISABLE 0x001B Yes Disable charger (Set CE bit of bq2419x) GG_CHGRCTL_ENABLE 0x001C Yes Enables the gas gauge to control the charger while continuously resetting the charger watchdog GG_CHGRCTL_DISABLE 0x001D Yes The gas gauge stops resetting the charger watchdog DIV_CUR_DISABLE 0x001E Yes Makes the programmed charge current to be same as what is calculated by the gauge charging algorithm. DF_VERSION 0x001F Yes Returns the data flash version SEALED 0x0020 No Places device in SEALED access mode IT_ENABLE 0x0021 No Enables the Impedance Track algorithm RESET 0x0041 No Forces a full reset of the bq27531-G1 SHIPMODE_ENABLE 0x0050 Yes Commands the bq2419x to turn off BATFET after a delay time programmed in data flash so that system load does not draw power from battery SHIPMODE_DISABLE 0x0051 Yes Commands the bq2419x to disregard turning off BATFET before delay time or turns on commands BATFET to turn on if an VBUS had power during the SHIPMODE enabling process CNTL FUNCTION DESCRIPTION Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 17 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 8.5.1.2 Charger Data Commands The charger registers are mapped to a series of single byte Charger Data Commands to enable system reading and writing of battery charger registers. During charger power up, the registers are initialized to Charger Reset State. The fuel gauge can change the values of these registers during the System Reset State. Each of the bits in the Charger Data Commands can be read/write. It is important to note that System Access can be different from the read/write access as defined in bq2419x charger hardware. The fuel gauge may block write access to the charger hardware when the bit function is controlled by the fuel gauge exclusively. For example, the [VREGx] bits of Chrgr_Voltage_Reg4 are controlled by the fuel gauge and cannot be modified by system. The bq27531 reads the corresponding registers of System_Stat_Reg8() and Fault_Reg9() every second to mirror the charger status. Other registers in the bq2419x are read when registers are modified by the bq27531. Table 3. Charger Data Commands COMMAND CODE bq2419x CHARGER MEMORY LOCATION SEALED ACCESS UNSEALED ACCESS CHGRSTAT 0x74 NA R R Every second Chrgr_InCtrl_Reg0() CHGR0 0x75 0x00 R/W R/W Data Change Chrgr_POR_Config_Reg1() CHGR1 0x76 0x01 R/W R/W Data Change Chrgr_Current_Reg2() CHGR2 0x77 0x02 R/W R/W Data Change Chrgr_PreTerm_Reg3() CHGR3 0x78 0x03 R/W R/W Data Change Chrgr_Voltage_Reg4() CHGR4 0x79 0x04 R/W R/W Data Change Chrgr_TermTimer_Reg5() CHGR5 0x7a 0x05 R/W R/W Data Change Chrgr_IRThermal_Reg6() CHGR6 0x7b 0x06 R/W R/W Data Change Chrgr_OpCtrl_Reg7() CHGR7 0x7c 0x07 R/W R/W Data Change Chrgr_Status_Reg8() CHGR8 0x7d 0x08 R/W R/W Every Second Chrgr_Fault_Reg9() CHGR9 0x7e 0x09 R/W R/W Every Second Chrgr_Rev_RegA() CHGRA 0x7f 0x0a R/W R/W Data Change NAME ChargerStatus() 18 Submit Documentation Feedback REFRESH RATE Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 8.5.2 Communications 8.5.2.1 I2C Interface The fuel gauge supports the standard I2C read, incremental read, quick read, one-byte write, and incremental write functions. The 7-bit device address (ADDR) is the most significant 7 bits of the hex address and is fixed as 1010101. The first 8 bits of the I2C protocol are, therefore, 0xAA or 0xAB for write or read, respectively. Host generated S ADDR[6:0] 0 A Gauge generated CMD [7:0] A DATA [7:0] A P S ADDR[6:0] 1 A (a) 1-byte write S ADDR[6:0] 0 A DATA [7:0] N P (b) quick read CMD [7:0] A Sr ADDR[6:0] 1 A DATA [7:0] N P (c) 1- byte read S ADDR[6:0] 0 A CMD [7:0] A Sr ADDR[6:0] 1 A DATA [7:0] A ... DATA [7:0] N P (d) incremental read S ADDR[6:0] 0 A CMD[7:0] A DATA [7:0] A DATA [7:0] A ... A P (e) incremental write (S = Start , Sr = Repeated Start , A = Acknowledge , N = No Acknowledge , and P = Stop). Figure 8. Supported I2C Formats The quick read returns data at the address indicated by the address pointer. The address pointer, a register internal to the I2C communication engine, increments whenever data is acknowledged by the bq27531-G1 or the I2C master. “Quick writes” function in the same manner and are a convenient means of sending multiple bytes to consecutive command locations (such as two-byte commands that require two bytes of data). The following command sequences are not supported: Attempt to write a read-only address (NACK after data sent by master): Figure 9. Attempt to Write a Read-Only Address Attempt to read an address above 0x6B (NACK command): Figure 10. Attempt to Read an Address Above 0x6B 8.5.2.2 I2C Time-Out The I2C engine releases both SDA and SCL if the I2C bus is held low for 2 seconds. If the bq27531-G1 is holding the lines, releasing them frees them for the master to drive the lines. If an external condition is holding either of the lines low, the I2C engine enters the low-power SLEEP mode. Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 19 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 8.5.2.3 I2C Command Waiting Time To ensure proper operation at 400 kHz, a t(BUF) ≥ 66 μs bus-free waiting time must be inserted between all packets addressed to the bq27531-G1 . In addition, if the SCL clock frequency (fSCL) is > 100 kHz, use individual 1-byte write commands for proper data flow control. The following diagram shows the standard waiting time required between issuing the control subcommand the reading the status result. For read-write standard command, a minimum of 2 seconds is required to get the result updated. For read-only standard commands, there is no waiting time required, but the host must not issue any standard command more than two times per second. Otherwise, the gauge could result in a reset issue due to the expiration of the watchdog timer. S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] A P 66ms S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] A P 66ms S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] 1 A DATA [7:0] A DATA [7:0] N P 66ms N P 66ms Waiting time inserted between two 1-byte write packets for a subcommand and reading results (required for 100 kHz < fSCL £ 400 kHz) S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] A 1 A DATA [7:0] A P DATA [7:0] A 66ms DATA [7:0] Waiting time inserted between incremental 2-byte write packet for a subcommand and reading results (acceptable for fSCL £ 100 kHz) S ADDR [6:0] DATA [7:0] 0 A A CMD [7:0] DATA [7:0] A Sr N P ADDR [6:0] 1 A DATA [7:0] A DATA [7:0] A 66ms Waiting time inserted after incremental read Figure 11. I2C Command Waiting Time 8.5.2.4 I2C Clock Stretching A clock stretch can occur during all modes of fuel gauge operation. In SLEEP and HIBERNATE modes, a short clock stretch occurs on all I2C traffic as the device must wake up to process the packet. In the other modes ( BAT INSERT CHECK , NORMAL, SLEEP+ ) clock stretching only occurs for packets addressed for the fuel gauge. The majority of clock stretch periods are small as the I2C interface performs normal data flow control. However, less frequent yet more significant clock stretch periods may occur as blocks of Data Flash are updated. The following table summarizes the approximate clock stretch duration for various fuel gauge operating conditions. Table 4. I2C Clock Stretching GAUGING MODE APPROXIMATE DURATION OPERATING CONDITION/COMMENT SLEEP HIBERNATE Clock stretch occurs at the beginning of all traffic as the device wakes up. ≤ 4 ms BAT INSERT CHECK NORMAL SLEEP+ Clock stretch occurs within the packet for flow control (after a start bit, ACK or first data bit). ≤ 4 ms Normal Ra table Data Flash updates. 24 ms 20 Data Flash block writes. 72 ms Restored Data Flash block write after loss of power. 116 ms End of discharge Ra table Data Flash update. 144 ms Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 9 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 9.1 Application Information The fuel gauge can control a bq2419x Charger IC without the intervention from an application system processor. Using the bq27531-G1 and bq2419x chipset, batteries can be charged with the typical constant-current, constant-voltage (CCCV) profile or charged using a Multi-Level Charging (MLC) algorithm. 9.2 Typical Application 1 2 Vin GND C5 1.0uF J1 1 2 3 4 PSEL PG STAT 5 6 7 8 9 10 11 12 BSCL BSDA OTG CE R7 REGN 80.6k 24 23 22 21 C2 10uF J5 2 1 L1 2.2uH C7 47nF 1 SW System Output GND SYS 2 C8 10uF C9 10uF C10 1uF C11 0.1uF TP13 SYS BAT+ C13 10uF R11 100k 169 C1 10uF REGN 4.7uF C6 20 19 18 17 16 15 14 13 25 R2 U1 BQ2419xRGE VBUS VBUS PSEL PMID PG REGN STAT BTST SCL SW SDA SW PGND INT PGND OTG CE SYS ILIM SYS TS 1 BAT TS2 BAT PwPd C14 1uF VCC R17 10.0k SDA SCL VSS J10 R18 10.0k SYS SDA 4 3 2 1 SCL CE OTG R19 J P3 1MΩ R20 SYS SYS R9 2.21k R8 2.21k J P4 D1 1MΩ Green D2 Green PG STAT VCC R23 10.0k SOC_INT SOC_INT 2 VSS 1 J13 SYS C15 0.1uF VCC R21 1.80M C17 1.0uF SDA SCL C18 0.033uF R22 18.2k U2 BQ27531-G1YFF E1 REGIN BAT D1 VCC CE B3 SDA SOC_INT A3 SCL E3 BI/TOUT BSCL BSDA D3 TS SRN C2 VSS SRP C1 VSS E2 D2 A2 B2 C3 B1 A1 BAT+ SYS SOC_INT BSCL BSDA TS_GAUGE 0.1uF C19 TS_GAUGE Vin Max: 4.4V Current max: 4A C16 0.1uF PACK+ 3 T 2 PACK1 J12 0.01 R24 R25 1.00k C20 0.1uF Only needed when the Gauge is monitoring the battery NTC. Figure 12. Typical Application Schematic Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 21 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com Typical Application (continued) 9.2.1 Design Requirements Several key parameters must be updated to align with a given application's battery characteristics. For highest accuracy gauging, it is important to follow-up this initial configuration with a learning cycle to optimize resistance and maximum chemical capacity (Qmax) values prior to sealing and shipping systems to the field. Successful and accurate configuration of the fuel gauge for a target application can be used as the basis for creating a "golden" gas gauge (.fs) file that can be written to all gauges, assuming identical pack design and Li-ion cell origin (chemistry, lot, and so on). Calibration data is included as part of this golden GG file to cut down on system production time. If going this route, TI recommends averaging the voltage and current measurement calibration data from a large sample size and use these in the golden file. Table 5 lists the items that must be configured to achieve reliable protection and accurate gauging with minimal initial configuration. Table 5. Key Data Flash Parameters for Configuration NAME DEFAULT UNIT RECOMMENDED SETTING Design Capacity 2425 mAh Set based on the nominal pack capacity as interpreted from cell manufacturer's datasheet. If multiple parallel cells are used, must be set to N × Cell Capacity. Reserve Capacity-mAh 0 mAh Set to desired runtime remaining (in seconds/3600) × typical applied load between reporting 0% SOC and reaching Terminate Voltage, if needed. Cycle Count Threshold 900 mAh Set to 90% of configured Design Capacity. Must be configured using TI-supplied Battery Management Studio software. Default open-circuit voltage and resistance tables are also updated in conjunction with this step. Do not attempt to manually update reported Device Chemistry as this does not change all chemistry information. Always update chemistry using the appropriate evaluation software tool. Chem ID 1202 hex Load Mode 0 — Set to applicable load model, 0 for constant current or 1 for constant power. Load Select 1 — Set to load profile which most closely matches typical system load. Qmax Cell 0 2425 mAh Set to initial configured value for Design Capacity. The gauge will update this parameter automatically after the optimization cycle and for every regular Qmax update thereafter. V at Chg Term Cell 0 4200 mV Set to nominal cell voltage for a fully charged cell. The gauge will update this parameter automatically each time full charge termination is detected. Terminate Voltage 3200 mV Set to empty point reference of battery based on system needs. Typical is between 3000 and 3200 mV. Ra Max Delta 44 mΩ Set to 15% of Cell0 R_a 4 resistance after an optimization cycle is completed. Charging Voltage 4200 mV Set based on nominal charge voltage for the battery in normal conditions (25°C, and so forth). Used as the reference point for offsetting by Taper Voltage for full charge termination detection. Taper Current 121 mA Set to the nominal taper current of the charger + taper current tolerance to ensure that the gauge will reliably detect charge termination. Taper Voltage 100 mV Sets the voltage window for qualifying full charge termination. Can be set tighter to avoid or wider to ensure possibility of reporting 100% SOC in outer JEITA temperature ranges that use derated charging voltage. Dsg Current Threshold 60 mA Sets threshold for gauge detecting battery discharge. Must be set lower than minimal system load expected in the application and higher than Quit Current. Chg Current Threshold 75 mA Sets the threshold for detecting battery charge. Can be set higher or lower depending on typical trickle charge current used. Also must be set higher than Quit Current. Quit Current 40 mA Sets threshold for gauge detecting battery relaxation. Can be set higher or lower depending on typical standby current and exhibited in the end system. Avg I Last Run –299 mA Current profile used in capacity simulations at onset of discharge or at all times if Load Select = 0. Must be set to nominal system load. Is automatically updated by the gauge every cycle. Avg P Last Run –1131 mW Power profile used in capacity simulations at onset of discharge or at all times if Load Select = 0. Must be set to nominal system power. Is automatically updated by the gauge every cycle. Sleep Current 10 mA Sets the threshold at which the fuel gauge enters SLEEP mode. Take care in setting above typical standby currents else entry to SLEEP may be unintentionally blocked. 22 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 Typical Application (continued) Table 5. Key Data Flash Parameters for Configuration (continued) NAME DEFAULT UNIT Charge T0 0 °C Sets the boundary between charging inhibit and charging with T0 parameters. Charge T1 10 °C Sets the boundary between charging with T0 and T1 parameters. Charge T2 45 °C Sets the boundary between charging with T1 and T2 parameters. Charge T3 50 °C Sets the boundary between charging with T2 and T3 parameters. Charge T4 60 °C Sets the boundary between charging with T3 and T4 parameters. Charge Current T0 50 % Des Cap Sets the charge current parameter for T0. Charge Current T1 100 % Des Cap Sets the charge current parameter for T1. Charge Current T2 100 % Des Cap Sets the charge current parameter for T2. Charge Current T3 100 % Des Cap Sets the charge current parameter for T3. Charge Current T4 0 % Des Cap Sets the charge current parameter for T4. Charge Voltage T0 262 16 mV Sets the charge voltage parameter for T0. Charge Voltage T1 262 16 mV Sets the charge voltage parameter for T1. Charge Voltage T2 259 16 mV Sets the charge voltage parameter for T2. Charge Voltage T3 256 16 mV Sets the charge voltage parameter for T3. Charge Voltage T4 0 16 mV Sets the charge voltage parameter for T4. Chg Temp Hys 5 °C Adds temperature hysteresis for boundary crossings to avoid oscillation if temperature is changing by a degree or so on a given boundary. Chg Disabled Regulation V 4200 mV Sets the voltage threshold for voltage regulation to system when charge is disabled. TI recommends programming to same value as Charging Voltage and maximum charge voltage that is obtained from Charge Voltage Tn parameters. CC Gain 10 mΩ Calibrate this parameter using TI-supplied evaluation software and calibration procedure in the TRM. Determines conversion of coulomb counter measured sense resistor voltage to current. CC Delta 10 mΩ Calibrate this parameter using TI-supplied evaluation software and calibration procedure in the TRM. Determines conversion of coulomb counter measured sense resistor voltage to passed charge. CC Offset –1418 Counts Calibrate this parameter using TI-supplied evaluation software and calibration procedure in the TRM. Determines native offset of coulomb counter hardware that must be removed from conversions. Board Offset 0 Counts Calibrate this parameter using TI-supplied evaluation software and calibration procedure in the TRM. Determines native offset of the printed-circuit-board parasitics that must be removed from conversions. mV Calibrate this parameter using TI-supplied evaluation software and calibration procedure in the TRM. Determines voltage offset between cell tab and ADC input node to incorporate back into or remove from measurement, depending on polarity. Pack V Offset 0 RECOMMENDED SETTING Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 23 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 9.2.2 Detailed Design Procedure 9.2.2.1 BAT Voltage Sense Input A ceramic capacitor at the input to the BAT pin is used to bypass AC voltage ripple to ground, greatly reducing its influence on battery voltage measurements. It proves most effective in applications with load profiles that exhibit high-frequency current pulses (that is, cell phones) but is recommended for use in all applications to reduce noise on this sensitive high-impedance measurement node. 9.2.2.2 SRP and SRN Current Sense Inputs The filter network at the input to the coulomb counter is intended to improve differential mode rejection of voltage measured across the sense resistor. These components must be placed as close as possible to the coulomb counter inputs and the routing of the differential traces length-matched to best minimize impedance mismatchinduced measurement errors. 9.2.2.3 Sense Resistor Selection Any variation encountered in the resistance present between the SRP and SRN pins of the fuel gauge will affect the resulting differential voltage, and derived current, it senses. As such, TI recommends selecting a sense resistor with minimal tolerance and temperature coefficient of resistance (TCR) characteristics. The standard recommendation based on best compromise between performance and price is a 1% tolerance, 100-ppm drift sense resistor with a 1-W power rating. 9.2.2.4 TS Temperature Sense Input Similar to the BAT pin, a ceramic decoupling capacitor for the TS pin is used to bypass AC voltage ripple away from the high-impedance ADC input, minimizing measurement error. Another helpful advantage is that the capacitor provides additional ESD protection, because the TS input to system may be accessible in systems that use removable battery packs. The capacitor must be placed as close as possible to the respective input pin for optimal filtering performance. 9.2.2.5 Thermistor Selection The fuel gauge temperature sensing circuitry is designed to work with a negative temperature coefficient-type (NTC) thermistor with a characteristic 10-kΩ resistance at room temperature (25°C). The default curve-fitting coefficients configured in the fuel gauge specifically assume a 103AT-2 type thermistor profile and so that is the default recommendation for thermistor selection purposes. Moving to a separate thermistor resistance profile (for example, JT-2 or others) requires an update to the default thermistor coefficients in data flash to ensure highest accuracy temperature measurement performance. 9.2.2.6 REGIN Power Supply Input Filtering A ceramic capacitor is placed at the input to the fuel gauge internal LDO to increase power supply rejection (PSR) and improve effective line regulation. It ensures that voltage ripple is rejected to ground instead of coupling into the internal supply rails of the fuel gauge. 9.2.2.7 VCC LDO Output Filtering A ceramic capacitor is also needed at the output of the internal LDO to provide a current reservoir for fuel gauge load peaks during high peripheral utilization. It acts to stabilize the regulator output and reduce core voltage ripple inside of the fuel gauge. 24 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 9.2.3 Application Curves 8.8 VREGIN = 2.7 V VREGIN = 4.5 V 2.6 fOSC - High Frequency Oscillator (MHz) VREG25 - Regulator Output Voltage (V) 2.65 2.55 2.5 2.45 2.4 2.35 8.7 8.6 8.5 8.4 8.3 8.2 8.1 8 -40 Temperature (qC) -20 0 20 40 Temperature (qC) D001 34 5 33.5 4 33 32.5 32 31.5 31 30.5 30 -40 -20 0 20 40 Temperature (qC) 60 80 100 100 D002 3 2 1 0 -1 -2 -3 -4 -5 -30 -20 D003 Figure 15. Low-Frequency Oscillator Frequency vs Temperature 80 Figure 14. High-Frequency Oscillator Frequency vs Temperature Reported Temperature Error (qC) fLOSC - Low Frequency Oscillator (kHz) Figure 13. Regulator Output Voltage vs Temperature 60 -10 0 10 20 30 Temperature (qC) 40 50 60 D004 Figure 16. Reported Internal Temperature Measurement vs Temperature Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 25 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 10 Power Supply Recommendations 10.1 Power Supply Decoupling Both the REGIN input pin and the VCC output pin require low equivalent series resistance (ESR) ceramic capacitors placed as close as possible to the respective pins to optimize ripple rejection and provide a stable and dependable power rail that is resilient to line transients. A 0.1-μF capacitor at the REGIN and a 1-μF capacitor at VCC will suffice for satisfactory device performance. 11 Layout 11.1 Layout Guidelines 11.1.1 Sense Resistor Connections Kelvin connections at the sense resistor are just as critical as those for the battery terminals themselves. The differential traces must be connected at the inside of the sense resistor pads and not anywhere along the highcurrent trace path to prevent false increases to measured current that could result when measuring between the sum of the sense resistor and trace resistance between the tap points. In addition, the routing of these leads from the sense resistor to the input filter network and finally into the SRP and SRN pins needs to be as closely matched in length as possible else additional measurement offset could occur. It is further recommended to add copper trace or pour-based "guard rings" around the perimeter of the filter network and coulomb counter inputs to shield these sensitive pins from radiated EMI into the sense nodes. This prevents differential voltage shifts that could be interpreted as real current change to the fuel gauge. All of the filter components need to be placed as close as possible to the coulomb counter input pins. 11.1.2 Thermistor Connections The thermistor sense input must include a ceramic bypass capacitor placed as close to the TS input pin as possible. The capacitor helps to filter measurements of any stray transients as the voltage bias circuit pulses periodically during temperature sensing windows. 11.1.3 High-Current and Low-Current Path Separation For best possible noise performance, it is extremely important to separate the low-current and high-current loops to different areas of the board layout. The fuel gauge and all support components must be situated on one side of the boards and tap off of the high-current loop (for measurement purposes) at the sense resistor. Routing the low-current ground around instead of under high-current traces will further help to improve noise rejection. 26 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 bq27531-G1 www.ti.com SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 11.2 Layout Example Battery power connection to system Use copper pours for battery power path to minimize IR losses SCL To system host processor SDA BSDA BATTERY PACK CONNECTOR To charger slave BSCL C1 PACK+ Kelvin connect the BAT sense line right at positive terminal to battery pack REGIN BAT C2 BI/TOUT CE Vcc BSDA VSS VSS SDA BSCL SRN SCL SOC_INT SRP C3 THERM TS INT PACK – 10 mΩ 1% Via connects to Power Ground Ground return to system Kelvin connect SRP and SRN connections right at Rsense terminals Figure 17. Layout Schematic Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 27 bq27531-G1 SLUSBE7C – MARCH 2013 – REVISED JANUARY 2016 www.ti.com 12 Device and Documentation Support 12.1 Documentation Support 12.1.1 Related Documentation To obtain a copy of any of the following TI documents, go to the TI website at www.ti.com. • bq27531-G1 Technical Reference Manual User's Guide (SLUUA96) • bq27531EVM with bq27531 Battery Management Unit Impedance Track™ Fuel Gauge and bq24192 4.5-A, Switch-Mode Battery Charger for Single-Cell Applications User's Guide (SLUUA90) 12.2 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 12.3 Trademarks Impedance Track, MaxLife, NanoFree, E2E are trademarks of Texas Instruments. All other trademarks are the property of their respective owners. 12.4 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 12.5 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 13 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. 28 Submit Documentation Feedback Copyright © 2013–2016, Texas Instruments Incorporated Product Folder Links: bq27531-G1 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) BQ27531YZFR-G1 ACTIVE DSBGA YZF 15 3000 RoHS & Green SNAGCU Level-1-260C-UNLIM -40 to 85 BQ27531 BQ27531YZFT-G1 ACTIVE DSBGA YZF 15 250 RoHS & Green SNAGCU Level-1-260C-UNLIM -40 to 85 BQ27531 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
BQ27531YZFT-G1 价格&库存

很抱歉,暂时无法提供与“BQ27531YZFT-G1”相匹配的价格&库存,您可以联系我们找货

免费人工找货