0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CC1101Q1EMK868-915

CC1101Q1EMK868-915

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    Module

  • 描述:

    EVAL MODULE FOR CC1101 915MHZ

  • 数据手册
  • 价格&库存
CC1101Q1EMK868-915 数据手册
SWRU126B December 2013 CC1101DK Quick Start Guide Opening the box and running the Packet Error Rate Test 1. Kit Contents 2. SmartRF04EB Overview LCD 3. Plug EM into SmartRF04EB EM connectors USB      2 x SmartRF04EB 2 x CC1101EM (433 or 868/915 MHz) 2 x Antennas (picture may deviate) 2 x USB cables Documentation The 868-915 MHz RF boards in this kit are FCC and IC certified. Both the 433 MHz and the 868-915 MHz boards are tested to comply with ETSI/R&TTE over temperatures from 0 to +35°C. Insert a CC1101EM (EM) with an antenna into the SmartRF04EB (EB). Make sure the antenna is firmly connected for best performance. UART LCD Joystick Button S1 Antenna types: 868-915 MHz: Pulse W5017, 2 dBi 420-470 MHz: Pulse SPWH24433TI, 0 dBi FCC/IC Regulatory Compliance (868-915 only) FCC Part 15 Class A Compliant IC ICES-003 Class A Compliant 4a. Power: Battery 4b. Power: DC/External Caution! The kit contains ESD sensitive components. Handle with care to prevent permanent damage. 4c. Power: USB There are three different ways of applying The second method applies DC power using power to the EB: the DC input jack (right in picture, center is +, sleeve is ground), or by connecting a 4-10V The first method involves using an alkaline voltage source between the 4-10V and 0V non-rechargeable battery, either a 9V or a terminals of the power connector (left in 4xAA battery pack connected to the battery picture). It is also possible to connect a 3.3V connector on the bottom side of the board voltage source between the 3.3V and 0V terminals. The on-board voltage regulators will Warning! To minimize risk of personal injury or be bypassed in this case. property damage, ONLY use alkaline nonrechargeable batteries. Never use External Power Supply1 Requirements: rechargeable batteries to power the board. Nom Voltage: 6 VDC Max Current: 800 mA Efficiency Level V The EB can also be powered from the USB bus. Make sure that the SmartRF™ Studio software is installed before connecting the EB to the PC; otherwise you may experience problems in installing it later due to driver issues. 5. Set Power Switch 6. Packet Error Rate Test 7. Set Frequency Band If a 3.3V source is used as described in 4b above, the switch should be set to the leftmost position. For all other cases, the switch should be set to the rightmost position. This switch can be used to turn off the EB by switching it to the opposite position of that used to turn it on When power is applied to the board, the PER test program will start. You should see the text shown above on the LCD display on both evaluation boards. Select the desired frequency band of operation by using the joystick. The frequency should match the evaluation module and antenna you are using. Press the button marked S1 (lower right corner) to continue. Note that the value shown in the display is also the selected value. There is no need to press a button to select or activate the selection. Do not leave the board powered when unattended. 1 Note that if multiple power sources are connected, the source with the highest voltage will power the EB. This means that you should disconnect any attached battery when using a lab supply or USB power; otherwise the battery will be drained. When using an external power supply, make sure it meets the listed requirements in addition to complying with applicable regional product regulatory and safety certification requirements such as UL, CSA, VDE, CCC, and PSE SWRU126B December 2013 8. Set Network ID 9. Packet Length 10. Number of Packets Push the joystick down to display the screen shown above. This lets you set the ID of the node in case you need to run several PER tests simultaneously and you have multiple development kits. Leave this set to 1 for now. Push the joystick down to display the screen shown above. This lets you set the length of the packets to be transmitted. The packet length will affect the measured packet error rate. Push the joystick left or right to select the packet length you want to use. Push the joystick down to display the screen shown above. This lets you set the number of packets to be transmitted. Set this to the desired value using the joystick. 11. Select RF Settings 12. Select Mode 13. Configure 2 Push the joystick down to display the screen shown above. This lets you select preset RF configurations, including modulation and data rate Push the joystick down to display the screen Perform steps 3 through 11 on the second EB. shown above. Use the joystick to select master Push the joystick down until you get the display mode. The EB you have configured now will be shown above. Leave this EB in slave mode. the master in the PER test. nd EB Preset 0: GFSK, 1.2 kBaud Preset 1: GFSK, 10 kBaud Preset 2: GFSK, 38.4 kBaud Preset 3: GFSK, 250 kBaud 14. Start PER 15. Run PER Test 16. References Please visit www.ti.com and http://www.ti.com/tool/cc1101dk433 http://www.ti.com/tool/cc1101dk868-915 Push the joystick down on both EBs, and the screen shown above is displayed. Push the joystick right on the slave EB first, and then push the joystick right on the master EB. The PER test will start when the two nodes have successfully connected. Download the CC1101DK User Manual, the SmartRF™ Studio software, examples, as well The uppermost line of the LCD will show the as datasheets, reference designs and PER for packets transmitted from the slave to application notes. the master, while the second line will show the PER for packets transmitted from the master to You will also find a lot of information on the TI E2E forum at http://e2e.ti.com the slave. The PER test will end when the number of We hope that you will enjoy working with Note that the PER test uses 10 dBm as default packets you selected in step 10 is reached or if the CC1101 device. output power, so the EBs should be placed at 100 consecutive packets are lost. least 1m apart to avoid saturation of the receiver. SmartRF™ Studio 1. Download and Install 2. Launch SmartRF Studio 3. Configure the Radio Before connecting the EB to your PC, download SmartRF™ Studio from www.ti.com/smartrfstudio. Install the program and follow the instructions in the wizard. Connect the EB with a CC1101EM to the PC using the USB cable. USB drivers will be Launch SmartRF Studio and double click on You can now configure the radio, run tests, the highlighted CC1101 device icon to get export register settings and run link tests with installed automatically. complete control of the device from the PC. another CC1101 on a SmartRF04EB connected to the PC. IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2016, Texas Instruments Incorporated
CC1101Q1EMK868-915 价格&库存

很抱歉,暂时无法提供与“CC1101Q1EMK868-915”相匹配的价格&库存,您可以联系我们找货

免费人工找货