User's Guide
SBOU211 – October 2018
Universal Difference Amplifier Evaluation Module
This user's guide describes the characteristics and operation of the universal difference amplifier
evaluation module (EVM) that is compatible with all standard pinout difference amplifiers. The EVM is
designed to evaluate the performance of these devices in a variety of common configurations and
supports both single and dual-supply operation. The amplifier interfaces with the board through a DIP
socket, allowing evaluation of any amplifier package with a DIP adapter board. A breakaway DIP adapter
section is included to accommodate both SOIC-8 and VSSOP-8 style packages. This document includes
the schematic, printed circuit board (PCB) layouts, and BOM. Throughout this document the terms
evaluation board, evaluation module, and EVM are synonymous with the Universal Diff-Amp EVM. Note
this EVM is not compatible with fully differential amplifiers.
1
2
3
4
5
6
7
Contents
Overview .....................................................................................................................
PCB Layout ...................................................................................................................
Schematic .....................................................................................................................
EVM Components ...........................................................................................................
Configurations ................................................................................................................
Bill of Materials ...............................................................................................................
Related Documentation from Texas Instruments ........................................................................
2
3
4
5
5
8
9
List of Figures
1
Supported Difference Amplifier Pinout .................................................................................... 2
2
DIFFAMP-EVM Top Side ................................................................................................... 3
3
DIFFAMP-EVM Bottom Side ............................................................................................... 3
4
DIFFAMP-EVM Schematic ................................................................................................. 4
5
Common Difference Amplifier Configurations ............................................................................ 6
6
AC Coupling with Output Integrator ....................................................................................... 7
Trademarks
All trademarks are the property of their respective owners.
SBOU211 – October 2018
Submit Documentation Feedback
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
1
Overview
www.ti.com
1
Overview
1.1
Features
This EVM is intended to provide basic functional evaluation of the amplifiers shown in Table 1 with the
pinout shown in Figure 1. The EVM provides the following features:
•
•
•
•
•
1.2
Breakaway DIP adapter boards for evaluation of multiple packages and easy comparison of devices
Intuitive layout for setting jumpers
Easy access to nodes with surface-mount test points
Reference voltage source flexibility
Support for a variety of configurations as a diff amp, current source, or precision inverting/non-inverting
amplifier
Diff-amp Pinout
This EVM is intended to evaluate diff-amps that have the pinout shown in Figure 1. Pin 8 is normally a no
connect pin, but some devices provide an additional reference input at this pin. Pin 8 is tied to ground on
the EVM, so these devices may also be tested but an additional reference is not supported. If it is desired
to evaluate an amplifier with a pinout different than that in Figure 1 than a custom DIP adapter board will
be required.
INA
1
8
NC / Ref 2
-In
2
7
V+
+In
3
6
Output
V-
4
5
Sense
±
Ref
+
Figure 1. Supported Difference Amplifier Pinout
1.3
Compatible Devices
Devices that are compatible with this EVMs are shown in Table 1.
Table 1. Compatible Devices
2
Device
Description
INA105
Precision Unity Gain Differential Amplifier
INA106
Precision Gain = 10 Differential Amplifier
INA132
Low Power, Single-Supply Difference Amplifier
INA133
High-Speed, Precision Difference Amplifier
INA134
Audio Differential Line Receivers, 0dB (G=1)
INA137
Audio Differential Line Receivers, +-6dB (G=1/2 or 2)
INA143
High-Speed, Precision, G = 10 or G = 0.1 Difference Amplifier
INA152
Single-Supply Difference Amplifier
INA154
High-Speed, Precision Difference Amplifier (G = 1)
INA157
High-Speed, Precision Difference Amplifier
INA159
High-Speed, Precision Gain of 0.2 Level Translation Difference
Amplifier
INA592
Wide Bandwidth, e-Trim Difference Amplifiers
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
SBOU211 – October 2018
Submit Documentation Feedback
PCB Layout
www.ti.com
2
PCB Layout
The top and bottom sides of the EVM are shown in Figure 2 and Figure 3, respectively.
NOTE: Board layouts are not to scale. These figures are intended to show how the board is laid out;
they are not intended to be used for manufacturing PCBs.
Figure 2. DIFFAMP-EVM Top Side
Figure 3. DIFFAMP-EVM Bottom Side
SBOU211 – October 2018
Submit Documentation Feedback
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
3
Schematic
3
www.ti.com
Schematic
Figure 4 shows the schematic for the PCB.
Figure 4. DIFFAMP-EVM Schematic
4
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
SBOU211 – October 2018
Submit Documentation Feedback
EVM Components
www.ti.com
4
EVM Components
4.1
Power
Power is applied to the device with test points VCC and VEE at TP1 and TP3, respectively. These test
points power both the socketed diff-amp and the onboard reference amplifier. The board is initially
populated with an OPA207 as the reference amplifier, but if a different device is used then take care that
the new device can operate with the same supply as the diff-amp.
4.2
Inputs
Inputs are applied to the device using test points VIN+ and VIN-. Alternately, they can be applied at
banana jacks J3 and J5. This is recommended if high currents will flow through the input. The jacks are
spaced a 1/4 inch apart to interface with standard connectors. Two footprints are provided at the input for
shunt resistors if it is desired to test an amplifier for a current sense application. Additionally, footprints are
provided for edge mount SMA connectors for easily interfacing with other EVMs or test equipment.
4.3
Output
The output of the circuit may be accessed through test point VO or by adding an SMA connector at J23.
4.3.1
Output Filtering
RO and CO provide the ability to apply a single-pole RC output filter. Care must be taken not to overload
the output with excess capacitance, as this could lead to stability issues. The cutoff frequency of the
output filter is calculated as shown in Equation 1:
1
fc-o =
2S u RO u CO
(1)
4.4
Reference
There are multiple methods of applying a reference voltage to the device. The reference voltage is set by
J9, which either connects the reference to ground or ties it to the output of the reference buffer. The
reference buffer is initially configured to generate a rail at mid-supply for single supply operation.
Alternatively, this jumper can be left unconnected and the desired voltage can be applied directly to the
VREF test point. It is also possible to connect J7 and configure the reference buffer as an integrator to ac
couple the output as shown in Figure 6.
4.5
Miscellaneous
C1, C2, C3, and C4 are the supply bypass capacitors for the device and are pre-populated with 0.1 µF
and 0.01µF capacitors that usually provide adequate power supply bypassing for U1. Refer to the
difference amplifier data sheet for further information. Similarly, C5, C6, C7, and C8 provide supply
bypassing for U2. Refer to the buffer amplifier data sheet for further information.
5
Configurations
5.1
Difference Amplifier
This EVM allows for many jumper-selectable configurations. Pins 1, 2, 3, and 5 of the amplifier are routed
to headers that allow the user to define what connections are made to the internal resistors. Note it is
always necessary for either pin 2 or pin 5 to route to the output to ensure closed loop operation with
negative feedback. Figure 5 shows several ways to configure the jumpers and the associated transfer
function. The exact gain depends on the ratio of resistors used in the selected difference amplifier. If the
resistors in the difference amplifier are not all equal, then reciprocal gains can be achieved in each
configuration as shown in the top two figures.
SBOU211 – October 2018
Submit Documentation Feedback
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
5
Configurations
Precision Diff-Amp
Precision Diff-Amp
(Reciprocal Gain)
Pin1 (J2) ± Vref
Pin2 (J4) ± VINPin3 (J8) ± VIN+
Pin5 (J6) - Vopa
Pin1 (J2) ± VIN+
Pin2 (J4) ± Vopa
Pin3 (J8) ± Vref
Pin5 (J6) ± VIN-
Ra
2
Rb
5
±
6
Rb
5
VIN-
1
§ Rb ·
¨
¸
© Ra ¹
Vopa
Vref
V
IN
V
IN
§ Ra ·
¨
¸
© Rb ¹
Vopa
REF
Vref
Ra
V
V
IN
V
IN
Precision Non-inverting Amplifier
Precision Inverting Amplifier
Pin1 (J2) ± VIN+
Pin2 (J4) ± GND
Pin3 (J8) ± VIN+
Pin5 (J6) ± Vopa
Pin1 (J2) ± GND
Pin2 (J4) ± VINPin3 (J8) ± GND
Pin5 (J6) ± Vopa
1
Rb
Rb
5
±
6
VIN-
Vopa
2
Ra
1
Rb
Rb
5
6
REF
Vopa
+
Ra
±
2
+
3
Ra
Ra
§ Rb ·
¨1
¸
© Ra ¹
Vopa
V
Vopa
IN
§ Rb ·
¨
¸
© Ra ¹
Improved Howland
Current Source
Pin1 (J2) ± Vref
Pin2 (J4) ± VINPin3 (J8) ± VIN+
Pin5 (J6) ± Vout
Pin1 (J2) ± RS
Pin2 (J4) ± VINPin3 (J8) ± VIN+
Pin5 (J6) ± Vout
2
Ra
5
±
1
VIN+
Ra
6
3
Rb
§ Rb ·
¨
¸
© Rb Ra ¹
5
Vopa
+
3
Rb
+
6
§ Rb ·
¨
¸
Ra ¹
Iout | ©
IN
Rs
Iout
1
Ra
V
IN
±
VIN-
2
Rb
Vopa
V
Precision Divider
Ra
VIN+
Vopa
3
Rb
3
VIN+
1
VIN+
Rb
V
6
Vopa
+
3
Ra
2
+
VIN+
Ra
±
VIN-
www.ti.com
Rb
V
IN
V
IN
Rs
Figure 5. Common Difference Amplifier Configurations
6
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
SBOU211 – October 2018
Submit Documentation Feedback
Configurations
www.ti.com
5.2
Reference Amplifier
An onboard amplifier provides flexibility in reference configuration. In the default configuration the amplifier
operates as a supply splitter, dividing the positive supply voltage in half and buffering it for single supply
operation.
5.2.1
Buffered Reference Voltage Connection
A buffered-reference configuration is useful when the source impedance is high (for example, a voltage
divider). Buffering a high-impedance source with an operational amplifier provides a low-impedance
source and preserves common-mode rejection. The reference amplifier voltage is derived from the
positive power supply and can be adjusted by changing the R5 and R6.
5.2.2
AC Coupled Output
It is possible to generate an ac coupled output by feeding the output of the diff-amp through an integrator
and back to the reference pin. The output of the integrator will drive the reference such that the dc voltage
at the output of the diff-amp matches the voltage applied to the non-inverting terminal of the reference
amplifier. R5 can be removed if it is desired to ground the input of the amplifier in dual supply operation.
The cutoff frequency will be set by the RC time constant of the integrator. This is sometimes preferable to
using ac coupling capacitors at the input because capacitors tend to have wide tolerance ranges and
mismatch in these capacitors can degrade the common-mode rejection of the amplifier. This can be
implemented by placing a jumper on J7, removing R3, and populating R4 and C9 as shown in Figure 6.
Ra
Rb
5
±
2
6
VIN-
Vout
+
3
1
C9
J7
VIN+
Ra
Rb
R4
±
+
R6
Figure 6. AC Coupling with Output Integrator
SBOU211 – October 2018
Submit Documentation Feedback
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
7
Bill of Materials
6
8
www.ti.com
Bill of Materials
Designator
Quantity
Value
Description
PackageReferen
ce
PartNumber
Manufacturer
C1, C2, C5, C6
4
0.01uF
CAP, CERM,
0.01 uF, 50 V,
+/- 10%, X7R,
0805
0805
C0805C103K5R
ACTU
Kemet
C3, C4, C7, C8
4
0.1uF
CAP, CERM, 0.1 0805
uF, 50 V, +/10%, X7R, 0805
C0805C104K5R
ACTU
Kemet
C10
1
1uF
CAP, CERM, 1
1206
µF, 50 V,+/10%, X7R, AECQ200 Grade 1,
1206
UMK316B7105K
LHT
Taiyo Yuden
H1, H2, H3, H4
4
Machine Screw,
Round, #4-40 x
1/4, Nylon,
Philips panhead
Screw
NY PMS 440
0025 PH
B&F Fastener
Supply
H5, H6, H7, H8
4
Standoff
1902C
Keystone
J1
1
Header,
2.54mm, 6x2,
Gold, SMT
Header,
2.54mm, 6x2,
Gold, TH
61031221121
Wurth Elektronik
J2, J8
2
Header,
2.54mm, 4x2,
Gold, SMT
Header,
2.54mm, 4x2,
SMT
95278801A08LF
FCI
J3, J5
2
Standard
Banana Jack,
Uninsulated,
5.5mm
Keystone_575-4
575-4
Keystone
J4, J6
2
Header,
2.54mm, 3x2,
Gold, SMT
Header,
2.54mm, 3x2,
SMT
TSM-103-01-LDV
Samtec
J7
1
Header, 2.54
mm, 2x1, Gold,
R/A, SMT
Header, 2.54
mm, 2x1, R/A,
SMT
878980204
Molex
J9
1
Header,
2.54mm, 3x1,
Gold, SMT
Header,
2.54mm, 3x1,
SMT
TSM-103-02-LSV
Samtek
R3, R7, R9
3
0
RES, 0, 5%,
0.25 W, AECQ200 Grade 0,
1206
1206
CRCW12060000 Vishay-Dale
Z0EA
R5, R6
2
10.0k
RES, 10.0 k, 1%, 1206
0.25 W, AECQ200 Grade 0,
1206
SH-J1, SH-J2,
SH-J3, SH-J4,
SH-J5, SH-J6,
SH-J7, SH-J8,
SH-J9, SH-J10
10
Shunt, 100mil,
Gold plated,
Black
Shunt 2 pos. 100 881545-2
mil
TE Connectivity
TP1, TP2, TP3,
TP4, TP5, TP6,
TP7, TP8, TP9,
TP10, TP11,
TP12, TP13,
TP14, TP15,
TP16, TP17,
TP18, TP19
19
Test Point,
Miniature, SMT
Testpoint_Keyst
one_Miniature
Keystone
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
ERJ-8ENF1002V Panasonic
5015
SBOU211 – October 2018
Submit Documentation Feedback
Related Documentation from Texas Instruments
www.ti.com
7
U1
1
High Precision,
Low Noise, Low
Power
Operational
Amplifier,
D0008A (SOIC8)
D0008A
OPA207IDR
Texas
Instruments
XU1
1
Socket, DIP-8,
2.54 mm Pitch,
SMT
Socket, DIP-8,
2.54 mm Pitch
110-87-308-41105191
Preci-Dip
C9
0
1uF
CAP, CERM, 1
1206
µF, 50 V,+/10%, X7R, AECQ200 Grade 1,
1206
UMK316B7105K
LHT
Taiyo Yuden
C11
0
0.01uF
CAP, CERM,
0.01 uF, 50 V,
+/- 10%, X7R,
1206
1206
C1206C103K5R
ACTU
Kemet
J10, J11, J12,
J13, J14, J15,
J16, J17, J18,
J19, J20, J21
0
Header,
2.54mm, 4x1,
Gold, Black, TH
Header,
TS-104-G-AA
2.54mm, 4x1, TH
J22, J23, J24
0
SMA(F) Jack, 50 SMA(F) Jack,
Ohm, SMT
SMT
EMPCB.SMAFS
TJ.B.HT
Taoglas Antenna
Solutions
R1
0
0.01
RES, 0.01, 1%,
1 W, 2010
2010
PMR50HZPFU1
0L0
Rohm
R2
0
0.01
RES, 0.01, 1%,
0.5 W, 1206
1206
CSR1206FK10L
0
Stackpole
Electronics Inc
R4
0
1.00Meg
RES, 1.00 M,
1%, 0.25 W,
1206
1206
MCR18EZHF100 Rohm
4
R8
0
10.0k
RES, 10.0 k, 1%, 1206
0.25 W, AECQ200 Grade 0,
1206
Samtec
ERJ-8ENF1002V Panasonic
Related Documentation from Texas Instruments
The following documents provide information regarding Texas Instruments' integrated circuits and support
tools for the EVM. This user's guide is available from the TI web site under literature number SBOU211.
Any letter appended to the literature number corresponds to the document revision that is current at the
time of the writing of this document. Newer revisions may be available from the TI web site, or call the
Texas Instruments' Literature Response Center at (800) 477-8924 or the Product Information Center at
(972) 644-5580. When ordering, identify the document by both title and literature number.
Table 2. Related Documentation
SBOU211 – October 2018
Submit Documentation Feedback
Document
Literature Number
OPA207 Product Data Sheet
SBOS826
Universal Difference Amplifier Evaluation Module
Copyright © 2018, Texas Instruments Incorporated
9
STANDARD TERMS FOR EVALUATION MODULES
1.
Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or
documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.
1.1 EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software
1.2 EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.
2
Limited Warranty and Related Remedies/Disclaimers:
2.1 These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.
2.2 TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques are used to the extent TI deems necessary. TI does not test all parameters of each EVM.
User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.
2.3 TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.
3
Regulatory Notices:
3.1 United States
3.1.1
Notice applicable to EVMs not FCC-Approved:
FCC NOTICE: This kit is designed to allow product developers to evaluate electronic components, circuitry, or software
associated with the kit to determine whether to incorporate such items in a finished product and software developers to write
software applications for use with the end product. This kit is not a finished product and when assembled may not be resold or
otherwise marketed unless all required FCC equipment authorizations are first obtained. Operation is subject to the condition
that this product not cause harmful interference to licensed radio stations and that this product accept harmful interference.
Unless the assembled kit is designed to operate under part 15, part 18 or part 95 of this chapter, the operator of the kit must
operate under the authority of an FCC license holder or must secure an experimental authorization under part 5 of this chapter.
3.1.2
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant:
CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC Interference Statement for Class A EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
3.2 Canada
3.2.1
For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210 or RSS-247
Concerning EVMs Including Radio Transmitters:
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Concernant les EVMs avec appareils radio:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concerning EVMs Including Detachable Antennas:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur
3.3 Japan
3.3.1
Notice for EVMs delivered in Japan: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page 日本国内に
輸入される評価用キット、ボードについては、次のところをご覧ください。
http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page
3.3.2
Notice for Users of EVMs Considered “Radio Frequency Products” in Japan: EVMs entering Japan may not be certified
by TI as conforming to Technical Regulations of Radio Law of Japan.
If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required to follow the
instructions set forth by Radio Law of Japan, which includes, but is not limited to, the instructions below with respect to EVMs
(which for the avoidance of doubt are stated strictly for convenience and should be verified by User):
1.
2.
3.
Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,
Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or
Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて
いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの
措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用
いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ
ンスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
3.3.3
Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧ください。http:/
/www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
3.4 European Union
3.4.1
For EVMs subject to EU Directive 2014/30/EU (Electromagnetic Compatibility Directive):
This is a class A product intended for use in environments other than domestic environments that are connected to a
low-voltage power-supply network that supplies buildings used for domestic purposes. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.
4
EVM Use Restrictions and Warnings:
4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT
LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling
or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.
4.3 Safety-Related Warnings and Restrictions:
4.3.1
User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.
4.3.2
EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.
4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,
state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.
5.
Accuracy of Information: To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate
as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.
6.
Disclaimers:
6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT
LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.
6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE
CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.
7.
USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS. USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS
LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.
8.
Limitations on Damages and Liability:
8.1 General Limitations. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,
INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS OR THE USE OF THE EVMS , REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, COST OF REMOVAL OR
REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, RETESTING,
OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS, LOSS OF SAVINGS, LOSS OF
USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL BE BROUGHT AGAINST TI
MORE THAN TWELVE (12) MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS
OCCURRED.
8.2 Specific Limitations. IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY USE OF AN EVM PROVIDED
HEREUNDER, INCLUDING FROM ANY WARRANTY, INDEMITY OR OTHER OBLIGATION ARISING OUT OF OR IN
CONNECTION WITH THESE TERMS, , EXCEED THE TOTAL AMOUNT PAID TO TI BY USER FOR THE PARTICULAR
EVM(S) AT ISSUE DURING THE PRIOR TWELVE (12) MONTHS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE
CLAIMED. THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT.
9.
Return Policy. Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)
will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.
10. Governing Law: These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,
without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2018, Texas Instruments Incorporated
IMPORTANT NOTICE AND DISCLAIMER
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE
DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS”
AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD
PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate
TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable
standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you
permission to use these resources only for development of an application that uses the TI products described in the resource. Other
reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third
party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims,
damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on
ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable
warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2018, Texas Instruments Incorporated