INA209AIPW

INA209AIPW

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP16

  • 描述:

    IC CURRENT MONITOR 1% 16TSSOP

  • 数据手册
  • 价格&库存
INA209AIPW 数据手册
INA209 INA 209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 High-Side Measurement, Bi-Directional Current/Power Monitor with I2C™ Interface FEATURES DESCRIPTION 1 • SENSES BUS VOLTAGES FROM 0V TO +26V • REPORTS CURRENT, VOLTAGE, AND POWER; STORES PEAKS • TRIPLE WATCHDOG LIMITS: – Lower Warning with Delay – Upper Over-limit, No Delay – Fast Analog Critical • HIGH ACCURACY: 1% MAX OVER TEMP 23 APPLICATIONS • • • • • • • • SERVERS TELECOM EQUIPMENT AUTOMOTIVE POWER MANAGEMENT BATTERY CHARGERS WELDING EQUIPMENT POWER SUPPLIES TEST EQUIPMENT VIN+ VIN- The INA209 also includes an analog comparator and a programmable digital-to-analog converter (DAC) that combine to provide the fastest possible responses to current overload conditions. The INA209 can be used together with hot swap controllers that already use a current sense resistor. The INA209 full-scale range can be selected to be either within the hot-swap controller sense limits, or wide enough to include them. VS (Supply Voltage) INA209 Critical DAC + CMP Filter Critical DAC - The INA209 is a high-side current shunt and power monitor with an I2C interface. The INA209 monitors both shunt drop and shunt bus voltage. A programmable calibration value, combined with an internal multiplier, enables direct readouts in amperes. An additional multiplying register calculates power in watts. The INA209 features two separate, onboard watchdog capabilities: a warning comparator and an over-limit comparator. The warning comparator is useful for monitoring lower warning limits and incorporates a user-defined delay. The over-limit comparator assists with monitoring upper limits that could require immediate system shutdown. Critical The INA209 senses across shunts on buses that can vary from 0V to 26V. The device uses a single +3V to +5.5V supply, drawing a maximum of 1.5mA of supply current. It is specified for operation from –25°C to +85°C. CMP Overlimit Watchdog Warning ´ Power Register Alert 2 IC Interface Current Register ADC Data CLK Voltage Register GND Convert GPIO 1 2 3 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. I2C is a trademark of NXP Semiconductors. All other trademarks are the property of their respective owners. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2007–2009, Texas Instruments Incorporated INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ORDERING INFORMATION (1) (1) PRODUCT PACKAGE-LEAD PACKAGE DESIGNATOR PACKAGE MARKING INA209 TSSOP-16 PW INA209A For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com. ABSOLUTE MAXIMUM RATINGS (1) Over operating free-air temperature range (unless otherwise noted). Supply Voltage, VS Analog Inputs, VIN+, VIN– INA209 UNIT 6 V Differential (VIN+) – (VIN–) (2) –26 to +26 V Common-Mode –0.3 to +26 V GND – 0.3 to +6 V Open-Drain Digital Outputs GPIO, Convert Pins Input Current Into Any Pin Open-Drain Digital Output Current GND – 0.3 to VS + 0.3 V 5 mA 10 mA Operating Temperature –40 to +125 °C Storage Temperature –65 to +150 °C Junction Temperature +150 °C Human Body Model 2000 V Charged-Device Model 1000 V Machine Model (MM) 150 V ESD Ratings (1) (2) 2 Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. VIN+ and VIN– may have a differential voltage of –26V to +26V; however, the voltage at these pins must not exceed the range –0.3V to +26V. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 ELECTRICAL CHARACTERISTICS: VS = +3.3V Boldface limits apply over the specified temperature range, TA = –25°C to +85°C. At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG (1) = 1, unless otherwise noted. INA209 PARAMETER TEST CONDITIONS MIN PGA = ÷ 1 0 PGA = ÷ 2 PGA = ÷ 4 TYP MAX UNIT ±40 mV 0 ±80 mV 0 ±160 mV PGA = ÷ 8 0 ±320 mV BRNG = 1 0 32 V BRNG = 0 0 16 VIN+ = 0V to 26V 100 INPUT Full-Scale Current Sense (Input) Voltage Range Bus Voltage (Input Voltage) Range (2) Common-Mode Rejection CMRR Offset Voltage, RTI (3) VOS PSRR ±10 ±100 µV PGA = ÷ 2 ±20 ±125 µV PGA = ÷ 4 ±30 ±150 µV PGA = ÷ 8 ±40 ±200 VS = 3V to 5.5V Current Sense Gain Error vs Temperature Input Impedance V dB PGA = ÷ 1 vs Temperature vs Power Supply 120 µV 0.1 µV/°C 10 µV/V ±40 m% 10 ppm/°C Active Mode VIN+ Pin 20 µA VIN– Pin 20 || 320 µA || kΩ Input Leakage Power-Down Mode VIN+ Pin 0.1 ±0.5 µA VIN– Pin 0.1 ±0.5 µA DC ACCURACY ADC Basic Resolution 12 Bits 1 LSB Step Size Shunt Voltage 10 µV Bus Voltage 4 mV Current Measurement Error ±0.2 over Temperature Bus Voltage Measurement Error ±0.2 over Temperature % ±1 % ±0.5 % ±1 Differential Nonlinearity ±0.1 Critical DAC Full-Scale Range 255 Critical DAC Accuracy ±0.5 Critical DAC Resolution mV ±1 mV ±0.3 Critical DAC Comparator Hysteresis (4) See Critical DAC Comparator Delay % Bits 1 Critical DAC Comparator Offset % LSB 8 Critical DAC 1 LSB Step Size (1) (2) (3) (4) ±0.5 ±1.6 mV (4) 5 µs BRNG is bit 13 of the Configuration Register. This parameter only expresses the full-scale range of the ADC scaling. In no event should more than 26V be applied to this device. Referred-to-input (RTI). User-programmable. See the Critical Comparator and Register sections. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 3 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com ELECTRICAL CHARACTERISTICS: VS = +3.3V (continued) Boldface limits apply over the specified temperature range, TA = –25°C to +85°C. At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. INA209 PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 12-Bit 532 586 µs 11-Bit 276 304 µs 10-Bit 148 163 µs 9-Bit 84 93 µs ADC TIMING ADC Conversion Time Minimum Convert Input Low Time µs 4 SMBus SMBus Timeout (5) 28 35 ms 1 µA V DIGITAL INPUTS (Convert, GPIO and SDA as Input, SCL, A0, A1) Input Capacitance 3 0 ≤ VIN ≤ VS Leakage Input Current 0.1 pF Input Logic Levels: VIH 0.7 (VS) 6 VIL –0.3 0.3 (VS) Hysteresis 500 V mV DIGITAL OUTPUTS GPIO Pin Output Low ISINK = 3mA GPIO Pin Output High ISOURCE = 3mA 0.15 VS – 0.4 0.4 VS – 0.15 V V OPEN-DRAIN DIGITAL OUTPUTS (Critical, Over-Limit, Warning, Alert, SDA) Logic '0' Output Level High-Level Output Leakage Current ISINK = 3mA 0.15 0.4 V VOUT = VS 0.1 1 µA POWER SUPPLY Operating Supply Range +5.5 V Quiescent Current +3 1 1.5 mA Quiescent Current, Power-Down Mode 6 15 µA Power-On Reset Threshold 2 V TEMPERATURE RANGE Specified Temperature Range –25 +85 °C Operating Temperature Range –40 +125 °C Thermal Resistance θJA TSSOP-16 (5) 4 +150 °C/W SMBus timeout in the INA209 resets the interface any time SCL or SDA is low for over 28ms. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 PIN CONFIGURATION INA209 Top View VIN+ 1 16 SMBus Alert VIN- 2 15 A1 Convert 3 14 A0 GND 4 13 SDA VS+ 5 12 SCL GPIO 6 11 GND Critical 7 10 VS+ Overlimit 8 9 Warning PIN DESCRIPTIONS PIN NO. NAME DESCRIPTION 1 VIN+ Positive differential shunt voltage. Connect to positive side of shunt resistor. 2 VIN– Negative differential shunt voltage. Connect to negative side of shunt resistor. Bus voltage is measured from this pin to ground. 3 Convert Used to trigger conversions in triggered mode. In triggered mode, this pin should normally be high and taken low to initiate conversion. It may be returned high after 4µs. If held low, the ADC converts each time a triggered mode command is written via the I2C bus. If not used, this line should be tied high. 4 GND 5 VS+ 6 GPIO General-purpose, user-programmable input/output. Totem-pole output. Connect to ground or supply if not used. Default state is as an input. 7 Critical Open-drain critical watchdog output (filter set in Critical DAC– Register). Default state is disabled; active-low; transparent (non-latched). 8 Overlimit Open-drain over-limit watchdog output. Default state is disabled; active-low; transparent (non-latched). 9 Warning Open-drain warning watchdog output (delay set in Critical DAC– Register). Default state is disabled; active-low; transparent (non-latched). Connect together with pin 11 to ground. Connect together with pin 10 to supply, 3V to 5.5V. 10 VS+ 11 GND Connect together with pin 5 to supply, 3V to 5.5V. Connect together with pin 4 to ground. 12 SCL Serial bus clock line. 13 SDA Serial bus data line. 14 A0 Address pin. Table 1 shows pin settings and corresponding addresses. 15 A1 Address pin. Table 1 shows pin settings and corresponding addresses. 16 SMBus Alert Open-drain SMBus alert output. Controlled in SMBus Alert Mask Register. Default state is disabled. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 5 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com TYPICAL CHARACTERISTICS At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. ADC SHUNT OFFSET vs TEMPERATURE 100 -10 80 -20 60 -30 40 Offset (mV) Gain (dB) FREQUENCY RESPONSE 0 -40 -50 -60 20 0 -20 -70 -40 -80 -60 -90 -80 -100 -100 100 10 1k 10k 100k 320mV Range 160mV Range 1M 80mV Range 0 -40 -25 Input Frequency (Hz) 40mV Range 25 Figure 1. 80 45 60 40 40 35 160mV Range 0 -20 -40 125 30 25 20 16V Range 32V Range 15 80mV Range 40mV Range -60 10 -80 5 0 -100 -40 -25 0 25 50 75 100 0 -40 -25 125 25 50 75 100 125 Temperature (°C) Temperature (°C) Figure 3. Figure 4. ADC BUS GAIN ERROR vs TEMPERATURE INTEGRAL NONLINEARITY vs INPUT VOLTAGE 100 20 80 15 60 10 40 16V Range 20 INL (mV) Gain Error (m%) 100 ADC BUS VOLTAGE OFFSET vs TEMPERATURE 50 Offset (mV) Gain Error (m%) ADC SHUNT GAIN ERROR vs TEMPERATURE 320mV Range 75 Figure 2. 100 20 50 Temperature (°C) 0 -20 0 -5 32V Range -40 5 -10 -60 -15 -80 -100 -40 -25 0 25 50 75 100 125 -20 -0.4 Temperature (°C) -0.2 -0.1 0 0.1 0.2 0.3 0.4 Input Voltage (V) Figure 5. 6 -0.3 Figure 6. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 TYPICAL CHARACTERISTICS (continued) At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. CRITICAL COMPARATOR FULL-SCALE ERROR vs TEMPERATURE CRITICAL COMPARATOR OFFSET vs TEMPERATURE 1.0 0.8 0.8 0.6 0.6 Offset (mV) 0.4 Full-Scale Error (mV) 1.0 Critical Comparator + 0.2 0 -0.2 -0.4 Critical Comparator - 0.2 0 -0.2 -0.4 -0.6 -0.6 -0.8 -0.8 -1.0 Critical Comparator + -1.0 0 -40 -25 Critical Comparator - 0.4 25 50 75 100 -40 -25 125 50 Figure 7. Figure 8. 75 100 125 100 125 ACTIVE IQ vs TEMPERATURE 1.2 VS+ = 5V VS = 5V 1.5 1.0 1.0 0.8 0.5 IQ (mA) Input Currents (mA) 25 Temperature (°C) INPUT CURRENTS WITH LARGE DIFFERENTIAL VOLTAGES (VIN+ at 12V, Sweep of VIN–) 2.0 0 Temperature (°C) VS+ = 3V 0 VS+ = 3V VS = 3V 0.6 0.4 -0.5 0.2 -1.0 VS+ = 5V 0 -1.5 0 10 5 15 20 25 30 -40 -25 25 50 Temperature (°C) Figure 9. Figure 10. 75 ACTIVE IQ vs I2C CLOCK FREQUENCY SHUTDOWN IQ vs TEMPERATURE 16 1.4 14 1.2 12 1.0 IQ (mA) 10 IQ (mA) 0 VIN- Voltage (V) VS = 5V 8 VS = 5V 0.8 VS = 3V 0.6 6 VS = 3V 4 0.4 0.2 2 0 0 -40 -25 0 25 50 75 100 125 1k 10k 100k Temperature (°C) SCL Frequency (Hz) Figure 11. Figure 12. 1M Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 10M 7 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com TYPICAL CHARACTERISTICS (continued) At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. SHUTDOWN IQ vs I2C CLOCK FREQUENCY 400 350 300 IQ (mA) 250 200 VS = 5V 150 100 VS = 3V 50 0 1k 10k 100k 1M 10M SCL Frequency (Hz) Figure 13. 8 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 Bus Voltage Channel Shunt Voltage Channel ADC (1) (1) (1) (1) (2) Data Registers PGA (In Configuration Register) Shunt Voltage Full-Scale Calibration Current Bus Voltage Power CMP CMP ´ ´ DAC DAC (2) (2) Peak-Hold Registers Shunt Voltage- Peak (2) (2) Shunt Voltage+ Peak Bus Voltage (2) Minimum Peak Bus Voltage (2) Maximum Peak Power Peak Critical DAC- (2) Critical DAC Hysteresis Critical DAC+ (2) (2) (2) CMP CMP CMP CMP CMP CMP CMP CMP Latch and Polarity Warning Registers and Output Programmable Delay (set in Critical DAC- Register) Warning Output Default: · Disabled · Active Low · Transparent (not latched) Overlimit Registers and Output Latch and Polarity Enable/Disable in SMBus/Enable Register Enable/Disable in SMBus/Enable Register Enable/Disable in SMBus/Enable Register Overlimit Output Default: · Disabled · Active Low · Transparent (not latched) Latch and Polarity NOTES: Dashed line indicates the flag is in the Status Register. (1) Read-only. (2) Read/Write. Shunt Voltage- Warning Shunt Voltage+ Warning Bus Voltage Under(2) Voltage Warning Bus Voltage Over(2) Voltage Warning Power Warning (2) (2) Bus Under-Voltage Over-limit Bus Over-Voltage Over-limit Power Over-limit (2) Programmable Delay (set in Critical DAC- Register) Critical Output Default: · Disabled · Active Low · Transparent (not latched) Warning (Open-Drain) Over-limit (Open-Drain) Critical (Open-Drain) INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 FUNCTIONAL BLOCK DIAGRAM Figure 14. Submit Documentation Feedback 9 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com APPLICATION INFORMATION The INA209 is a digital current-shunt monitor with an I2C and SMBus-compatible interface. It provides digital current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems. Programmable registers allow flexible configuration for setting warning limits, measurement resolution, and continuousversus-triggered operation. Detailed register information appears at the end of this data sheet, beginning with Table 2. See the Functional Block Diagram for a block diagram of the INA209. To address a specific device, the master initiates a START condition by pulling the data signal line (SDA) from a HIGH to a LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte on the rising edge of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA LOW. Data transfer is then initiated and eight bits of data are sent, followed by an Acknowledge bit. During data transfer, SDA must remain stable while SCL is HIGH. Any change in SDA while SCL is HIGH is interpreted as a START or STOP condition. The INA209 offers compatability with I2C and SMBus interfaces. The I2C and SMBus protocols are essentially compatible with each other. I2C will be used throughout this document, with SMBus being specified only when a difference between the two systems is being addressed. Two bi-directional lines, SCL and SDA, connect the INA209 to the bus. Both SCL and SDA are open-drain connections. Figure 15 shows a typical application circuit. Once all data have been transferred, the master generates a STOP condition, indicated by pulling SDA from LOW to HIGH while SCL is HIGH. The INA209 includes a 28ms timeout on its interface to prevent locking up an SMBus. BUS OVERVIEW The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates START and STOP conditions. Current Shunt Load Supply Voltage (INA209 Power Supply Range is 3V to 5.5V) Supply 3.3V Supply CBYPASS 0.1mF VIN+ VIN- INA209 VS Critical DAC + CMP Filter Critical DAC - Critical Output CMP Overlimit Output Watchdog Warning Output ´ Power Register Alert 2 Current Register IC Interface Data (SDA) ADC Clock (SCL) Voltage Register GND Convert GPIO Figure 15. Typical Application Circuit 10 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Serial Bus Address WRITING TO/READING FROM THE INA209 To communicate with the INA209, the master must first address slave devices via a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation. Accessing a particular register on the INA209 is accomplished by writing the appropriate value to the register pointer. Refer to Table 2 for a complete list of registers and corresponding addresses. The value for the register pointer as shown in Figure 19 is the first byte transferred after the slave address byte with the R/W bit LOW. Every write operation to the INA209 requires a value for the register pointer. The INA209 has two address pins, A0 and A1. Table 1 describes the pin logic levels for each of the 16 possible addresses. The state of pins A0 and A1 is sampled on every bus communication and should be set before any activity on the interface occurs. The address pins are read at the start of each communication event. Table 1. INA209 Address Pins and Slave Addresses A1 A0 SLAVE ADDRESS GND GND 1000000 GND VS+ 1000001 GND SDA 1000010 GND SCL 1000011 VS+ GND 1000100 VS+ VS+ 1000101 VS+ SDA 1000110 VS+ SCL 1000111 SDA GND 1001000 SDA VS+ 1001001 SDA SDA 1001010 SDA SCL 1001011 SCL GND 1001100 SCL VS+ 1001101 SCL SDA 1001110 SCL SCL 1001111 Serial Interface The INA209 operates only as a slave device on the I2C bus and SMBus. Connections to the bus are made via the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The INA209 supports the transmission protocol for fast (1kHz to 400kHz) and high-speed (1kHz to 3.4MHz) modes. All data bytes are transmitted most significant byte first. Writing to a register begins with the first byte transmitted by the master. This byte is the slave address, with the R/W bit LOW. The INA209 then acknowledges receipt of a valid address. The next byte transmitted by the master is the address of the register to which data will be written. This register address value updates the register pointer to the desired register. The next two bytes are written to the register addressed by the register pointer. The INA209 acknowledges receipt of each data byte. The master may terminate data transfer by generating a START or STOP condition. When reading from the INA209, the last value stored in the register pointer by a write operation determines which register is read during a read operation. To change the register pointer for a read operation, a new value must be written to the register pointer. This write is accomplished by issuing a slave address byte with the R/W bit LOW, followed by the register pointer byte. No additional data are required. The master then generates a START condition and sends the slave address byte with the R/W bit HIGH to initiate the read command. The next byte is transmitted by the slave and is the most significant byte of the register indicated by the register pointer. This byte is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master acknowledges receipt of the data byte. The master may terminate data transfer by generating a Not-Acknowledge after receiving any data byte, or generating a START or STOP condition. If repeated reads from the same register are desired, it is not necessary to continually send the register pointer bytes; the INA209 retains the register pointer value until it is changed by the next write operation. Figure 16 and Figure 17 show read and write operation timing diagrams, respectively. Note that register bytes are sent most-significant byte first, followed by the least significant byte. Figure 18 shows the timing diagram for the SMBus Alert response operation. Figure 19 illustrates a typical register pointer configuration. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 11 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com Start By Master 1 1 1 1 0 0 A3 A2 A1 A0 (1) R/W Frame 1 Two-Wire Slave Address Byte 0 A3 A2 A1 A0 (1) 9 ACK By INA209 R/W 1 P7 P6 9 ACK By INA209 1 D15 D14 P4 P3 P2 D13 P1 Frame 2 Register Pointer Byte P5 D12 D11 D10 D9 (2) From INA209 Frame 2 Data MSByte 9 ACK By INA209 P0 1 D15 D14 D13 D8 9 1 D7 ACK By Master D9 Frame 3 Data MSByte D12 D11 D10 NOTES: (1) The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. (2) Read data is from the last register pointer location. If a new register is desired, the register pointer must be updated. See Figure 19. (3) ACK by Master can also be sent. 0 Frame 1 Two-Wire Slave Address Byte D8 D6 9 ACK By INA209 D5 1 D7 D4 D3 From INA209 D5 D4 D2 D3 D1 (2) D2 Frame 3 Data LSByte D6 9 9 ACK By INA209 D0 NoACK By Master D0 D1 Frame 4 Data LSByte (3) Stop Stop By Master Product Folder Link(s): INA209 SCL SDA SCL SDA Start By Master NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Copyright © 2007–2009, Texas Instruments Incorporated Submit Documentation Feedback 12 Figure 17. Timing Diagram for Read Word Format Figure 16. Timing Diagram for Write Word Format INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 ALERT 1 9 1 9 SCL SDA 0 0 0 1 1 0 0 1 R/W Start By Master 0 0 A3 A2 ACK By INA209 A1 A0 0 From INA209 Frame 1 SMBus ALERT Response Address Byte Frame 2 Slave Address Byte NACK By Master Stop By Master (1) NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 18. Timing Diagram for SMBus ALERT 1 9 1 9 SCL ¼ SDA 1 0 0 A3 A2 A1 A0 R/W Start By Master P7 P6 P5 P4 P3 P2 P1 ACK By INA209 Frame 1 Two-Wire Slave Address Byte (1) P0 Stop ACK By INA209 Frame 2 Register Pointer Byte NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 19. Typical Register Pointer Set Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 13 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com High-Speed I2C Mode The master then generates a repeated start condition (a repeated start condition has the same timing as the start condition). After this repeated start condition, the protocol is the same as F/S mode, except that transmission speeds up to 3.4Mbps are allowed. Instead of using a stop condition, repeated start conditions should be used to secure the bus in HS-mode. A stop condition ends the HS-mode and switches all the internal filters of the INA209 to support the F/S mode. When the bus is idle, both the SDA and SCL lines are pulled high by the pull-up devices. The master generates a start condition followed by a valid serial byte containing High-Speed (HS) master code 00001XXX. This transmission is made in fast (400kbps) or standard (100kbps) (F/S) mode at no more than 400kbps. The INA209 does not acknowledge the HS master code, but does recognize it and switches its internal filters to support 3.4Mbps operation. t(LOW) tF tR t(HDSTA) SCL t(HDSTA) t(HIGH) t(SUSTO) t(SUSTA) t(HDDAT) t(SUDAT) SDA t(BUF) P S S P Figure 20. Bus Timing Diagram Bus Timing Diagram Definitions FAST MODE PARAMETER HIGH-SPEED MODE MIN MAX MIN MAX UNITS SCL Operating Frequency f(SCL) 0.001 0.4 0.001 3.4 MHz Bus Free Time Between STOP and START Condition t(BUF) 600 160 ns Hold time after repeated START condition. After this period, the first clock is generated. t(HDSTA) 100 100 ns Repeated START Condition Setup Time t(SUSTA) 100 100 ns STOP Condition Setup Time t(SUSTO) 100 100 ns Data Hold Time t(HDDAT) 0 0 ns Data Setup Time t(SUDAT) 100 10 ns SCL Clock LOW Period t(LOW) 1300 160 ns SCL Clock HIGH Period t(HIGH) 600 60 Clock/Data Fall Time tF Clock/Data Rise Time Clock/Data Rise Time for SCLK ≤ 100kHz 14 ns 300 160 ns tR 300 160 ns tR 1000 Submit Documentation Feedback ns Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Power-Up Conditions BASIC ADC FUNCTIONS Power-up conditions apply to a software reset via the RST bit (bit 15) in the Configuration Register, or the I2C bus General Call Reset. At device power up, all Status bits are masked. Warning, Over-Limit, Critical, and SMBus Alert functions are disabled. All watchdog outputs default to active low and transparent (non-latched) modes. The two analog inputs to the INA209, VIN+ and VIN–, connect to a shunt resistor in the bus of interest. The INA209 is typically powered by a separate supply from +3V to +5.5V. The bus being sensed can vary from 0V to 26V. There are no special considerations for power-supply sequencing (for example, a bus voltage can be present with the supply voltage off, and vice-versa). The INA209 senses the small drop across the shunt for shunt voltage, and senses the voltage with respect to ground from VIN– for the bus voltage. Figure 21 illustrates this operation. VSHUNT = VIN+ - VINTypically < 50mV Current Shunt Supply Load Supply Voltage VIN+ VIN- INA209 Power Supply 3V to 5.5V VS INA209 Critical DAC + CMP Filter Critical CMP Critical DAC - Overlimit VBUS = VIN- - GND Watchdog Range of 0V to 26V Typical Application 12V Warning ´ Power Register Alert 2 IC Interface Current Register ADC Data CLK Voltage Register GND Convert GPIO Figure 21. INA209 Configured for Shunt and Bus Voltage Measurement Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 15 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com When the INA209 is in the normal operating mode (that is, MODE bits of the Configuration Register are set to '111'), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration Register, SADC bits). The device then converts the bus voltage up to the number set in the bus voltage averaging (Configuration Register, BADC bits). The Mode control in the Configuration Register also permits selecting modes to convert only voltage or current, either continuously or in response to an event (triggered). All current and power calculations are performed in the background and do not contribute to conversion time; conversion times shown in the Electrical Characteristics table can be used to determine the actual conversion time. Power-Down mode reduces the quiescent current and turns off current into the INA209 inputs, avoiding any supply drain. Full recovery from Power-Down requires 40µs. ADC Off mode (set by the Configuration Register, MODE bits) stops all conversions. In triggered mode, the external Convert line becomes active. Convert commands are initiated by taking the Convert line low for a minimum of 4µs. The Convert line may be connected high when unused. Any re-trigger of the Convert line during a conversion is ignored, and the Convert line state is disregarded until the conversion ends. There are several available triggered modes; however, all conversions are performed repeatedly up to the number set in the Averaging function (Configuration Register, BADC and SADC bits). If the Convert line is held low, writing any of the triggered convert modes into the Configuration Register (even if the desired mode is already programmed into the register) triggers a single-shot conversion. Although the INA209 can be read at any time, and the data from the last conversion remain available, the Conversion Ready bit (Status Register, CNVR bit) is provided to help co-ordinate one-shot or triggered conversions. The Conversion Ready bit is set after all conversions, averaging, and multiplication operations are complete. 16 The Conversion Ready bit clears under these conditions: 1. Writing to the Configuration Register, except when configuring the MODE bits for Power Down or ADC off (Disable) modes; 2. Reading the Status Register; or 3. Triggering a single-shot conversion with the Convert pin. Power Measurement Current and bus voltage are converted at different points in time, depending on the resolution and averaging mode settings. For instance, when configured for 12-bit and 128 sample averaging, up to 68ms in time between sampling these two values is possible. Again, these calculations are performed in the background and do not add to the overall conversion time. Peak-Hold Registers Shunt voltage peak registers hold the lowest and highest converted reading for the shunt value. The shunt value may be either positive or negative; as a result, there is a need for a sign bit in either register. For instance, the Shunt Voltage Positive Peak Register in most systems records a positive voltage; in most unidirectional current measurement applications, the Shunt Voltage Negative Peak Register also records a positive voltage. However, certain conditions can occur in normally unidirectional systems that cause a negative polarity across the shunt; these events are recorded in the Shunt Voltage Negative Peak Register. Peak-hold registers do not record conditions that trigger a Critical Comparator shutdown. A Critical Comparator shutdown occurs within 5µs of detecting a critical condition, while the ADC conversion necessary to record a peak-hold requires 532µs. Therefore, a system shutdown removes the fault before the analog-to-digital conversion (ADC) can record it. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Critical Comparator PGA Function The Critical Comparator function is included to provide the fastest possible response to overload events. This function bypasses the digital circuit by capturing the event in the analog domain. If larger full-scale shunt voltages are desired, the INA209 provides a PGA function that increases the full-scale range up to 2, 4, or 8 times (320mV). Additionally, the bus voltage measurement has two full-scale ranges: 16V or 32V. The Critical Comparator responds only to shunt voltage, and can be programmed for a value from 0mV to 255mV (in 1mV increments) in the Critical DAC+ and Critical DAC– Registers. Two thresholds are provided, allowing users to set different thresholds in systems where bi-directional current measurement occurs. For example, a power supply may readily allow sourcing of 10A, but must indicate an alarm whenever sinking more than 1A. The SMBus Alert Mask/Enable Control Register allows the user to enable or disable the Critical pin output through the CREN bit. The CREN bit affects only the Critical pin; it does not affect the CRIT+ or CRIT– flags within the Status Register. The Critical Comparator output filter is set by the CF bits of the Critical DAC– Register. This filter determines the duration of time that the CMP output must be continuously active (not toggling) to propagate to the Critical pin output and set the CRIT+ or CRIT– flags within the Status Register. While the Critical Comparator output filter provides settings from 0ms to 0.96ms, the CMP is actually strobed every 4µs, providing multiple samples per delay period. For the Critical output pin to become active, the critical condition must be true for every sample during the specified delay period. When using the Critical Comparator in unidirectional applications, where the Critical DAC– Register is unused, the Comparator could trip in error if the input is near zero, because the comparator can have an offset of up to ±1.5mV. Noise also contributes to false tripping. To avoid false tripping in unidirectional applications, the Critical DAC– should be programmed to a value beyond –2mV to account for the offset, and an additional amount to provide a noise margin. Alternatively, the Critical DAC– can be programmed to negative full-scale range (–255mV), in order to eliminate false tripping. Compatibility with TI Hot Swap Controllers The INA209 is designed for compatibility with hot swap controllers such the TI TPS2490. The TPS2490 uses a high-side shunt with a limit at 50mV; the INA209 full-scale range of 40mV enables the use of the same shunt for current sensing below this limit. When sensing is required at (or through) the 50mV sense point of the TPS2490, the PGA of the INA209 can be set to ÷2 to provide an 80mV full-scale range. A typical application connects the Critical pin output to the TPS2490 enable line; this configuration enables user-programmable current limits. Note that the latched mode should be used for the Critical pin output to avoid oscillation at the trip level. Filtering and Input Considerations Measuring current is often noisy, and such noise can be difficult to define. The INA209 offers several options for filtering by choosing resolution and averaging in the Configuration Register. These filtering options can be set independently for either voltage or current measurement. The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500kHz (±10%) typical sampling rate. This architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling rate harmonics can cause problems. Because these signals are at 1MHz and higher, they can be dealt with by incorporating filtering at the input of the INA209. The high frequency enables the use of low-value series resistors on the filter for negligible effects on measurement accuracy. Figure 22 shows the INA209 with an additonal filter added at the input. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 17 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com Current Shunt Load Supply RFILTER 10W RFILTER 10W Supply Voltage 0.1mF to 1mF Ceramic Capcitor 3.3V Supply VIN+ VIN- INA209 VS Critical DAC + CMP Filter Critical DAC - Critical Output CMP Overlimit Output Watchdog Warning Output ´ Alert Power Register 2 Current Register IC Interface Data (SDA) ADC Clock (SCL) Voltage Register GND Convert GPIO Figure 22. INA209 with Input Filtering Overload conditions are another consideration for the INA209 inputs. The INA209 inputs are specified to tolerate 26V across the inputs. A large differential scenario might be a short to ground on the load side of the shunt. This type of event can result in full power-supply voltage across the shunt (as long the power supply or energy storage capacitors support it). It must be remembered that removing a short to ground can result in inductive kickbacks that could exceed the 26V differential and common-mode rating of the INA209. Inductive kickback voltages are best dealt with by zener-type transient-absorbing devices (commonly called transzorbs) combined with sufficient energy storage capacitance. In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most likely cause of this event, particularly in applications with no large electrolytics present. This problem occurs because an excessive dV/dt can activate the ESD protection in the INA209 in systems where large currents are 18 available. Testing has demonstrated that the addition of 10Ω resistors in series with each input of the INA209 sufficiently protects the inputs against dV/dt failure up to the 26V rating of the INA209. These resistors have no significant effect on accuracy. SMBus Alert Response The ALERT interrupt pin is set whenever Warning, Over-Limit, Critical faults, or Conversion Ready states (in triggered modes) occur. The ALERT interrupt output signal is latched and can be cleared only by either reading the Status Register or by successfully responding to an alert response address. If the fault is still present, the ALERT pin re-asserts. Asserting the ALERT pin does not halt automatic conversions that are already in progress. The ALERT output pin is open-drain, allowing multiple devices to share a common interrupt line. The ALERT output can be disabled via the SMBus Alert Mask/Enable Control Register using the SMAEN bit. When disabled, the ALERT pin goes to a high state. The INA209 responds to the SMBus alert response address, an interrupt pointer return-address feature. The SMBus alert response interrupt pointer provides Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 quick fault identification for simple slave devices. When an ALERT occurs, the master can broadcast the alert response slave address (0001 100). Following this alert response, any slave devices that generated interrupts identify themselves by putting the respective addresses on the bus. VIN+ VIN- VS Critical Overlimit INA209 The alert response can activate several different slave devices simultaneously, similar to the I2C General Call. If more than one slave attempts to respond, bus arbitration rules apply; the device with the lower address code wins. The losing device does not generate an Acknowledge and continues to hold the ALERT line low until the interrupt is cleared. Successful completion of the read alert response protocol clears the SMBus ALERT pin, provided that the condition causing the alert no longer exists. The SMBus Alert flag is cleared separately by either reading the Status Register or by disabling the SMBus Alert function. The Status Register flags indicate which (if any) of the watchdogs have been activated. After power-on reset (POR), the normal state of all flag bits is '0', assuming that no alarm conditions exist. The flags are cleared by any successful read of the Status Register, after a conversion is complete and the fault no longer exists. Warning 2 IC Bus Alert Data Clk Gnd VIN+ VIN- Convert GPIO VS Critical Overlimit INA209 Warning Alert Data Clk Gnd VIN+ VIN- Convert VS Critical All Other Latches Overlimit The latches in the Configuration Register for the Warning, Over-Limit, and Critical outputs are not associated with the SMBus alert response, and are cleared whenever the Status Register is read. If the fault remains, they continue to set (they may also be cleared by setting the latch enable to transparent, and then returning it to latch mode). The values in the Peak-Hold Registers must be cleared by writing a '1' to the respective LSBs. INA209 Warning Alert Data Clk Gnd VIN+ VIN- Convert VS Critical Multichannel Data Acquisition Overlimit INA209 The INA209 can be used in multiple current measurement channels where the controlling processor sums the currents of all the channels for a total current. Often these current measurements must occur simultaneously. Use the GPIO output from one of the INA209s and connect it to the Convert pin of the other INA209s. This architecture allows for sending conversion commands via the I2C bus to the master device, and all devices will convert simultaneously. Figure 23 illustrates this architecture using four INA209s. Warning Alert Data Clk Gnd Convert Figure 23. Multichannel Data Acquisition with Simultaneous Sampling Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 19 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com External Circuitry for Additional VBUS Input The INA209 GPIO can be used to control an external circuit to switch the VBUS measurement to an alternate location. Switching is most often done to perform bus voltage measurements on the opposite side of a MOSFET switch in series with the shunt resistor. Consideration must be given to the typical 20µA input current of each INA209 input, along with the 320kΩ impedance present at the VIN– input where the bus voltage is measured. These effects can create errors Shunt RSHUNT through the resistance of any external switching method used. The easiest way to avoid these errors is by reducing this resistance to a minimum; select switching MOSFETs with the lowest possible RDS(on) values. The circuit shown in Figure 24 uses MOSFET pairs to reduce package count. Back-to-back MOSFETs must be used in each leg because of the built-in back diodes from source-to-drain. In this circuit, the normal connection for VIN– is at the shunt, with the optional voltage measurement at the output of the control FET. Control FET From Hot Swap Controller 10kW 10kW P-channel MOSFETs dual pairs such as Vishay Si3991DV Supply Voltage VIN+ VIN- N-channel MOSFETs dual pair such as Vishay Si1034 INA209 VS Critical DAC + CMP Filter Critical DAC - Critical Output CMP Overlimit Output Watchdog Warning Output ´ Power Register Alert 2 Current Register IC Interface ADC CLK (SCL) Voltage Register GND Convert Data (SDA) GPIO Figure 24. External Circuitry for Additional VBUS Input 20 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 PROGRAMMING THE INA209 POWER MEASUREMENT ENGINE Calibration Register and Scaling The Calibration Register makes it possible to set the scaling of the Current and Power Registers to whatever values are most useful for a given application. One strategy may be to set the Calibration Register such that the largest possible number is generated in the Current Register or Power Register at the expected full-scale point; this approach yields the highest resolution. The Calibration Register can also be selected to provide values in the Current and Power Registers that either provide direct decimal equivalents of the values being measured, or yield a round LSB number. After these choices have been made, the Calibration Register also offers possibilities for end user system-level calibration, where the value is adjusted slightly to cancel total system error. Below are two examples for configuring the INA209 calibration. Both examples are written so the information directly relates to the calibration set up found in the INA209EVM softwar. Calibration Example 1: Calibrating the INA209 with no possibility for overflow. (Note that the numbers used in this example are the same used with the INA209EVM software as shown in Figure 25. 1. Establish the following parameters: VBUS_MAX = 32 VSHUNT_MAX = 0.32 RSHUNT = 0.5 2. Using Equation 1, determine the maximum possible current . VSHUNT_MAX MaxPossible_I = RSHUNT MaxPossible_I = 0.64 (1) 3. Choose the desired maximum current value. This value is selected based on system expectations. Max_Expected_I = 0.6 4. Calculate the possible range of current LSBs. To calculate this range, first compute a range of LSBs that is appropriate for the design. Next, select an LSB within this range. Note that the results will have the most resolution when the minimum LSB is selected. Typically, an LSB is selected to be the nearest round number to the minimum LSB value. Max_Expected_I Minimum_LSB = 32767 Minimum_LSB = 18.311 ´ 10-6 (2) Max_Expected_I 4096 Maximum_LSB = 146.520 ´ 10-6 Maximum_LSB = (3) Choose an LSB in the range: Minimum_LSB 320.00 2. Translate this number to a whole decimal number ==> 32000 3. Convert it to binary==> 111 1101 0000 0000 4. Complement the binary result : 000 0010 1111 1111 5. Add 1 to the Complement to create the Two’s Complement formatted result ==> 000 0011 0000 0000 6. Extend the sign and create the 16-bit word: 1000 0011 0000 0000 = 8300h (Remember to extend the sign to all sign-bits, as necessary based on the PGA setting.) At PGA = ÷8, full-scale range = ±320mV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300), and LSB = 10µV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SD14_8 SD13_8 SD12_8 SD11_8 SD10_8 SD9_8 SD8_8 SD7_8 SD6_8 SD5_8 SD4_8 SD3_8 SD2_8 SD1_8 SD0_8 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷4, full-scale range = ±160mV (decimal = 16000, positive value hex = 3E80, negative value hex = C180), and LSB = 10µV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SD13_4 SD12_4 SD11_4 SD10_4 SD9_4 SD8_4 SD7_4 SD6_4 SD5_4 SD4_4 SD3_4 SD2_4 SD1_4 SD0_4 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷2, full-scale range = ±80mV (decimal = 8000, positive value hex = 1F40, negative value hex = E0C0), and LSB = 10µV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SIGN SD12_2 SD11_2 SD10_2 SD9_2 SD8_2 SD7_2 SD6_2 SD5_2 SD4_2 SD3_2 SD2_2 SD1_2 SD0_2 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷1, full-scale range = ±40mV (decimal = 4000, positive value hex = 0FA0, negative value hex = F060), and LSB = 10µV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SIGN SIGN SD11_1 SD10_1 SD9_1 SD8_1 SD7_1 SD6_1 SD5_1 SD4_1 SD3_1 SD2_1 SD1_1 SD0_1 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 34 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Table 6. Shunt Voltage Register Format (1) VSHUNT Reading (mV) Decimal Value PGA = ÷ 8 (D15…..................D0) PGA = ÷ 4 (D15…..................D0) PGA = ÷ 2 (D15…..................D0) PGA = ÷ 1 (D15…..................D0) 320.02 32002 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.01 32001 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.00 32000 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.99 31999 0111 1100 1111 1111 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.98 31998 0111 1100 1111 1110 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.02 16002 0011 1110 1000 0010 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.01 16001 0011 1110 1000 0001 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.00 16000 0011 1110 1000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 159.99 15999 0011 1110 0111 1111 0011 1110 0111 1111 0001 1111 0100 0000 0000 1111 1010 0000 159.98 15998 0011 1110 0111 1110 0011 1110 0111 1110 0001 1111 0100 0000 0000 1111 1010 0000 80.02 8002 0001 1111 0100 0010 0001 1111 0100 0010 0001 1111 0100 0000 0000 1111 1010 0000 80.01 8001 0001 1111 0100 0001 0001 1111 0100 0001 0001 1111 0100 0000 0000 1111 1010 0000 80.00 8000 0001 1111 0100 0000 0001 1111 0100 0000 0001 1111 0100 0000 0000 1111 1010 0000 79.99 7999 0001 1111 0011 1111 0001 1111 0011 1111 0001 1111 0011 1111 0000 1111 1010 0000 79.98 7998 0001 1111 0011 1110 0001 1111 0011 1110 0001 1111 0011 1110 0000 1111 1010 0000 40.02 4002 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0000 40.01 4001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0000 40.00 4000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 39.99 3999 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 39.98 3998 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0.02 2 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0.01 1 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 –0.01 –1 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 –0.02 –2 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 –39.98 –3998 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 –39.99 –3999 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 –40.00 –4000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 –40.01 –4001 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0110 0000 –40.02 –4002 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0110 0000 –79.98 –7998 1110 0000 1100 0010 1110 0000 1100 0010 1110 0000 1100 0010 1111 0000 0110 0000 –79.99 –7999 1110 0000 1100 0001 1110 0000 1100 0001 1110 0000 1100 0001 1111 0000 0110 0000 –80.00 –8000 1110 0000 1100 0000 1110 0000 1100 0000 1110 0000 1100 0000 1111 0000 0110 0000 –80.01 –8001 1110 0000 1011 1111 1110 0000 1011 1111 1110 0000 1100 0000 1111 0000 0110 0000 –80.02 –8002 1110 0000 1011 1110 1110 0000 1011 1110 1110 0000 1100 0000 1111 0000 0110 0000 –159.98 –15998 1100 0001 1000 0010 1100 0001 1000 0010 1110 0000 1100 0000 1111 0000 0110 0000 –159.99 –15999 1100 0001 1000 0001 1100 0001 1000 0001 1110 0000 1100 0000 1111 0000 0110 0000 –160.00 –16000 1100 0001 1000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.01 –16001 1100 0001 0111 1111 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.02 –16002 1100 0001 0111 1110 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.98 –31998 1000 0011 0000 0010 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.99 –31999 1000 0011 0000 0001 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.00 –32000 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.01 –32001 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.02 –32002 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 (1) Out-of-range values are shown in grey shading. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 35 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com Bus Voltage Register 04h (Read-Only) The Bus Voltage Register stores the most recent bus voltage reading, VBUS. At full-scale range = 32V (decimal = 8000, hex = 1F40), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BD12 BD11 BD10 BD9 BD8 BD7 BD6 BD5 BD4 BD3 BD2 BD1 BD0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At full-scale range = 16V (decimal = 4000, hex = 0FA0), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME 0 BD11 BD10 BD9 BD8 BD7 BD6 BD5 BD4 BD3 BD2 BD1 BD0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Register 05h (Read-Only) Full-scale range and LSB are set by the Calibration Register. See the Programming the INA209 Power Measurement Engine section. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PD15 PD14 PD13 PD12 PD11 PD10 PD9 PD8 PD7 PD6 PD5 PD4 PD3 PD2 PD1 PD0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The Power Register records power in watts by multiplying the values of the current with the value of the bus voltage according to the equation: Current ´ BusVoltage Power = 5000 Current Register 06h (Read-Only) Full-scale range and LSB depend on the value entered in the Calibration Register. See the Programming the INA209 Power Measurement Engine section. Negative values are stored in two's complement format. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME CSIGN CD14 CD13 CD12 CD11 CD10 CD9 CD8 CD7 CD6 CD5 CD4 CD3 CD2 CD1 CD0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The value of the Current Register is calculated by multiplying the value in the Shunt Voltage Register with the value in the Calibration Register according to the equation: Current = 36 ShuntVoltage ´ Calibration Register 4096 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 PEAK-HOLD REGISTERS Note: All peak-hold registers are cleared and reset to POR values by writing a '1' into the respective D0 bits. Shunt Voltage Positive Peak Register 07h (Read/Write) Mirrors highest voltage reading of the Shunt Voltage Register (03h). BIT # D15 BIT NAME SPP SIGN D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 SPP14 SPP13 SPP12 SPP11 SPP10 SPP9 SPP8 SPP7 SPP6 SPP5 SPP4 SPP3 POR VALUE 1 0 0 0 0 0 0 0 0 0 0 0 D2 D1 D0 SPP2 SPP1 SPP0/R S 0 0 0 0 D3 D2 D1 D0 Shunt Voltage Negative Peak Register 08h (Read/Write) Mirrors lowest voltage reading (positive or negative) of the Shunt Voltage Register (03h). BIT # D15 BIT NAME SPN SIGN D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 SPN14 SPN13 SPN12 SPN11 SPN10 SPN9 SPN8 SPN7 SPN6 SPN5 SPN4 SPN3 SPN2 SPN1 SPN0/R S POR VALUE 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Bus Voltage Maximum Peak Register 09h (Read/Write) Mirrors highest voltage reading of the Bus Voltage Register (04h). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BH12 BH11 BH10 BH9 BH8 BH7 BH6 BH5 BH4 BH3 BH2 BH1 BH0 — — BPK/RS POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bus Voltage Minimum Peak Register 0Ah (Read/Write) Mirrors lowest voltage reading of the Bus Voltage Register (04h). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BL12 BL11 BL10 BL9 BL8 BL7 BL6 BL5 BL4 BL3 BL2 BL1 BL0 — — BL/RS POR VALUE 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 Power Peak Register 0Bh (Read/Write) Mirrors highest reading of the Power Register (05h). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PPK15 PPK14 PPK13 PPK12 PPK11 PPK10 PPK9 PPK8 PPK7 PPK6 PPK5 PPK4 PPK3 PPK2 PPK1 PPK0/R S POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 37 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com WARNING WATCHDOG REGISTERS These registers set warning limits that trigger flags in the Status Register and activate the Warning pin. Note: Delayed output is set in the Critical DAC– Register (15h). Shunt Voltage Positive Warning Register 0Ch (Read/Write) At full-scale range = ±320mV, 15-bit + sign, LSB = 10µV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SWP SIGN SWP14 SWP13 SWP12 SWP11 SWP10 SWP9 SWP8 SWP7 SWP6 SWP5 SWP4 SWP3 SWP SWP1 SWP0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions SWP: Sets the shunt voltage positive warning limit. Bits 15–0 If the value of the Shunt Voltage Register (03h) exceeds this limit, the WS+ bit of the Status Register (01h) is set to '1' and the Warning pin asserts if the WRNEN bit is set. Shunt Voltage Negative Warning Register 0Dh (Read/Write) At full-scale range = ±320mV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300), 15 bit + sign, LSB = 10µV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SWN SIGN SWN14 SWN13 SWN12 SWN11 SWN10 SWN9 SWN8 SWN7 SWN6 SWN5 SWN4 SWN3 SWN2 SWN1 SWN0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions SWN: Sets the shunt voltage negative warning limit. Bits 15–0 If the value of the Shunt Voltage Register (03h) is below this limit, the WS– bit of the Status Register (01h) is set to '1' and the Warning pin asserts if the WRNEN bit is set. Power Warning Register 0Eh (Read/Write) At full-scale range, same as the Power Register. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PW15 PW14 PW13 PW12 PW11 PW10 PW9 PW8 PW7 PW6 PW5 PW4 PW3 PW2 PW1 PW0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions PW: Sets the power warning limit. Bits 15–0 If the value of the Power Register (05h) exceeds this limit, the WP bit of the Status Register (01h) is set to '1' and the Warning pin asserts if the WRNEN bit is set. Bus Over-Voltage Warning Register 0Fh (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BWO12 BWO11 BWO10 BWO9 BWO8 BWO7 BWO6 BWO5 BWO4 BWO3 BWO2 BWO1 BWO0 — WPL WNL POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 38 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Bit Descriptions BWO: Sets the bus over-voltage warning limit. Bits 15–3 If a Bus Voltage Register (04h) value exceeds this limit, the WOV bit of the Status Register (01h) is set to '1' and the Warning pin asserts if the WRNEN bit is set. WPL: The Warning Polarity bit sets the Warning pin polarity. Bit 1 1 = Inverted (active-high open collector) 0 = Normal (active-low open collector) (default) WNL: The Warning Latch bit configures the latching feature of the Warning pin. Bit 0 1 = Latch enabled 0 = Transparent (default) Bus Under-Voltage Warning Register 10h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BWU12 BWU11 BWU10 BWU9 BWU8 BWU7 BWU6 BWU5 BWU4 BWU3 BWU2 BWU1 BWU0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions BWU: Sets the bus over-voltage warning limit. Bits 15–3 If a Bus Voltage Register (04h) value is below this limit, the WUV bit of the Status Register (01h) is set to '1' and the Warning pin asserts if the WRNEN bit is set. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 39 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com OVER-LIMIT/CRITICAL WATCHDOG REGISTERS These registers set the over-limit and critical DAC limits that trigger flags to be set in the Status Register and activate the Overlimit pin or the Critical pin. Power Over-Limit Register 11h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PO15 PO14 PO13 PO12 PO11 PO10 PO9 PO8 PO7 PO6 PO5 PO4 PO3 PO2 PO1 PO0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions PO: Sets the power over-limit value. Bits 15–0 If the value of the Power Register (05h) exceeds this limit, the OLP bit of the Status Register (01h) is set to '1' and the Overlimit pin asserts if the OLEN bit is set. Bus Over-Voltage Over-Limit Register 12h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BOO12 BOO11 BOO10 BOO9 BOO8 BOO7 BOO6 BOO5 BOO4 BOO3 BOO2 BOO1 BOO0 — OLP OLL POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions BOO: Sets the bus over-voltage over-limit value. Bits 15–3 If a Bus Voltage Register (04h) value exceeds this limit, the OLOV bit of the Status Register (01h) is set to '1' and the Overlimit pin asserts if the OLEN bit is set. OLP: The Over-Limit Polarity bit sets the Overlimit pin polarity. Bit 1 1 = Inverted (asserts high) 0 = Normal (asserts low) (default) OLL: The Over-Limit Latch bit configures the latching feature of the Overlimit pin. Bit 0 1 = Latch enabled 0 = Transparent (default) Bus Under-Voltage Over-Limit Register 13h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BUO12 BUO11 BUO10 BUO9 BUO8 BUO7 BUO6 BUO5 BUO4 BUO3 BUO2 BUO1 BUO0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions BUO: Sets the bus under-voltage over-limit value. Bits 15–3 If a Bus Voltage Register (04h) value is below this limit, the OLUV bit of the Status Register (01h) is set to '1' and the Overlimit pin asserts if the OLEN bit is set. 40 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Critical DAC+ Register (Critical Shunt Positive Voltage) 14h (Read/Write) No sign bit (sets a positive limit only). At full-scale range = 255mV; LSB = 1mV; 8-bit. BIT # D15 D14 D13 D12 D11 D10 D9 D8 BIT NAME CDP7 CDP6 CDP5 CDP4 CDP3 CDP2 CDP1 CDP0 POR VALUE 0 0 0 0 0 0 0 0 (1) D7 GP x D6 D5 D4 D3 D2 D1 D0 CHYST 1 CHYST 0 CRL 0 0 0 GMP1 GPM0 CP CHYST 2 0 0 0 0 (1) POR value reflects the state of the GPIO pin. Bit Descriptions CDP: Critical DAC+ limit setting. Bits 15–8 GP: GPIO read back. Bit 7 Shows state of the GPIO pin. GPM: GPIO mode bit. Bits 6, 5 The GPIO mode settings are shown in Table 7. Table 7. GPIO Mode Settings (1) (1) GPM1 GPM0 STATE NOTES 0 0 Hi-Z 0 1 Hi-Z Use as an input in either of these modes. 1 0 0 1 1 1 Shaded values are default. CP: Configures the Critical output pin polarity (open-drain output). Bit 4 1 = Active high 0 = Active low (default) CHYST: Configures Critical comparator hysteresis. Bits 3–1 The CHYST settings are shown in Table 8. Table 8. CHYST Settings (1) (1) CHYST2 CHYST1 CHYST0 HYSTERESIS 0 0 0 0mV 0 0 1 2mV 0 1 0 4mV 0 1 1 6mV 1 0 0 8mV 1 0 1 10mV 1 1 0 12mV 1 1 1 14mV Shaded values are default. CRL: Configures Critical pin latch feature. Bit 0 1 = Latch enabled 0 = Transparent (default) Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 41 INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com Critical DAC– Register (Critical Shunt Negative Voltage) 15h (Read/Write) No sign bit (sets negative limit only). At full-scale range = –255mV; LSB = 1mV; 8-bit. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME CDP7 CDP6 CDP5 CDP4 CDP3 CDP2 CDP1 CDP0 CF3 CF2 CF1 CF0 WD3 WD2 WD1 WD0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit Descriptions CDP: Critical DAC- limit setting. Bits 15–8 CF: Configures DAC Comparator output filter. Bits 7–4 Ranges from 0 to 0.96ms; 64s/LSB. CF settings are listed in Table 9. WD: Configures Warning pin Output Delay from 0 to 1.5s; 0.1 second/LSB. Bits 3–0 Default = 0. WD settings are listed in Table 10. Table 9. CF Settings 42 FILTER SETTING (ms) CF3 CF2 CF1 CF0 0 0 0 0 0 0 0 0 1 0.064 0 0 1 0 0.128 0 0 1 1 0.192 0 1 0 0 0.256 0 1 0 1 0.320 0 1 1 0 0.384 0 1 1 1 0.448 1 0 0 0 0.512 1 0 0 1 0.576 1 0 1 0 0.640 1 0 1 1 0.704 1 1 0 0 0.768 1 1 0 1 0.832 1 1 1 0 0.896 1 1 1 1 0.960 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 INA209 www.ti.com ......................................................................................................................................................... SBOS403B – JUNE 2007 – REVISED MARCH 2009 Table 10. WD Settings WD3 WD2 WD1 WD0 DELAY SETTING (s) 0 0 0 0 0 0 0 0 1 0.1 0 0 1 0 0.2 0 0 1 1 0.3 0 1 0 0 0.4 0 1 0 1 0.5 0 1 1 0 0.6 0 1 1 1 0.7 1 0 0 0 0.8 1 0 0 1 0.9 1 0 1 0 1.0 1 0 1 1 1.1 1 1 0 0 1.2 1 1 0 1 1.3 1 1 1 0 1.4 1 1 1 1 1.5 Calibration Register 16h (Read/Write) Current and power calibration are set by bits D15 to D1 of the Calibration Register. Note that bit D0 is not used in the calculation. This register sets the current that corresponds to a full-scale drop across the shunt. Full-scale range and the LSB of the current and power measurement depend on the value entered in this register. See the Programming the INA209 Power Measurement Engine section. This register is suitable for use in overall system calibration. Note that the '0' POR values are all default. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 (1) BIT NAME FS14 FS13 FS12 FS11 FS10 FS9 FS8 FS7 FS6 FS5 FS4 FS3 FS2 FS1 FS0 FRB POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (1) D0 is a void bit and will always be '0'. It is not possible to write a '1' to D0. CALIBRATION is the value stored in D15:D1. Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 43 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) INA209AIPW ACTIVE TSSOP PW 16 90 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 INA209A INA209AIPWR ACTIVE TSSOP PW 16 2000 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 INA209A (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
INA209AIPW 价格&库存

很抱歉,暂时无法提供与“INA209AIPW”相匹配的价格&库存,您可以联系我们找货

免费人工找货
INA209AIPW
    •  国内价格
    • 1000+21.34000

    库存:21890