0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SN65HVD257D

SN65HVD257D

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    SOIC8_150MIL

  • 描述:

    IC TRANSCEIVER HALF 1/1 8SOIC

  • 数据手册
  • 价格&库存
SN65HVD257D 数据手册
Product Folder Sample & Buy Support & Community Tools & Software Technical Documents SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 SN65HVD25x Turbo CAN Transceivers for Higher Data Rates and Large Networks Including Features for Functional Safety 1 Features 3 Description • • This CAN transceiver meets the ISO1189-2 High Speed CAN (Controller Area Network) Physical Layer standard. It is designed for data rates in excess of 1 Mbps for CAN in short networks, and enhanced timing margin and higher data rates in long and highly-loaded networks. The device provides many protection features to enhance device and CANnetwork robustness. The SN65HVD257 device adds additional features, allowing for easy design of redundant and multitopology networks with fault indication for higher levels of functional safety in the CAN system. 1 • • • • Meets the Requirements of ISO11898-2 Turbo CAN: – Short and Symmetrical Propagation Delay Times and Fast Loop Times for Enhanced Timing Margin – Higher Data Rates in CAN Networks I/O Voltage Range Supports 3.3-V and 5-V MCUs Ideal Passive Behavior When Unpowered – Bus and Logic Pins are High Impedance (No Load) – Power Up and Power Down With Glitch-Free Operation on Bus Protection Features – HBM ESD Protection Exceeds ±12 kV – Bus Fault Protection –27 V to 40 V – Undervoltage Protection on Supply Pins – Driver Dominant Time Out (TXD DTO) – SN65HVD257: Receiver-Dominant Time Out (RXD DTO) – SN65HVD257: FAULT Output Pin – Thermal Shutdown Protection Characterized for –40°C to 125°C Operation Device Information(1) PART NUMBER PACKAGE SN65HVD255 SN65HVD256 SN65HVD257 BODY SIZE (NOM) SOIC (8) 4.90 mm × 3.91 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. Block Diagram NC / VRXD / FAULT (See Note A) 5 3 FAULT LOGIC MUX (See Note A) VCC VCC VCC OVER TEMPERATURE 7 2 Applications • • • • • • 1-Mbps Operation in Highly Loaded CAN Networks Down to 10-kbps Networks Using TXD DTO Industrial Automation, Control, Sensors, and Drive Systems Building, Security, and Climate Control Automation Telecom Base Station Status and Control SN65HVD257: Functional Safety With Redundant and Multitopology CAN networks CAN Bus Standards Such as CANopen, DeviceNet, NMEA2000, ARNIC825, ISO11783, and CANaerospace TXD S 1 DOMINANT TIME OUT 8 6 CANH CANL MODE SELECT UNDER VOLTAGE VCC or V RXD (See Note B) RXD 4 LOGIC OUTPUT DOMINANT TIME OUT (See Note B) 2 GND A. Pin 5 function is device dependent; NC on the SN65HVD255 device, VRXD for RXD output level-shifting device on the SN65HVD256 device, and FAULT Output on the SN65HVD257 device. B. RXD logic output is driven to 5-V VCC on 5-V only supply devices (SN65HVD255, SN65HVD257) and driven to VRXD on the output level-shifting device (SN65HVD256). C. RXD (Receiver) Dominant State Time Out is a device-dependent option available only on the SN65HVD257 device. 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Table of Contents 1 2 3 4 5 6 7 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Device Options....................................................... Pin Configuration and Functions ......................... Specifications......................................................... 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 8 9 1 1 1 2 4 4 5 Absolute Maximum Ratings ...................................... 5 ESD Ratings.............................................................. 5 Recommended Operating Conditions....................... 6 Thermal Information .................................................. 6 Electrical Characteristics........................................... 7 Power Dissipation ..................................................... 9 Switching Characteristics .......................................... 9 Typical Characteristics ............................................ 10 Parameter Measurement Information ................ 11 Detailed Description ............................................ 14 9.1 9.2 9.3 9.4 Overview ................................................................. Functional Block Diagram ....................................... Feature Description................................................. Device Functional Modes........................................ 14 14 14 19 10 Application and Implementation........................ 22 10.1 Application Information.......................................... 22 10.2 Typical Applications .............................................. 23 11 Power Supply Recommendations ..................... 27 12 Layout................................................................... 27 12.1 Layout Guidelines ................................................. 27 12.2 Layout Example .................................................... 28 13 Device and Documentation Support ................. 28 13.1 13.2 13.3 13.4 Related Links ........................................................ Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 28 28 28 28 14 Mechanical, Packaging, and Orderable Information ........................................................... 28 4 Revision History Changes from Revision C (September 2013) to Revision D • Page Added Pin Configuration and Functions section, ESD Ratings table, Switching Characteristics table, Typical Characteristics section, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section ................................................................................................. 1 Changes from Revision B (June 2012) to Revision C Page • Added Table 1, Receiver Differential Input Voltage Threshold Test .................................................................................... 12 • Added Figure 13, Example Timing Diagram for TXD DTO and FAULT Pin ........................................................................ 17 • Added Bus Loading, Length, and Number of Nodes subsection ......................................................................................... 22 Changes from Revision A (June 2012) to Revision B • Page Added SN65HVD257 status to production in Ordering Information table .............................................................................. 4 Changes from Original (December 2011) to Revision A Page • Updated the Features list ....................................................................................................................................................... 1 • Updated the Applications list .................................................................................................................................................. 1 • Added text to the Description section..................................................................................................................................... 1 • Changed Block Diagram - Functional Block Diagram to include HVD257 and Note changes............................................... 1 • Changed the DEVICE OPTIONS table................................................................................................................................... 4 • Added SN65HVD257 to the D PACKAGE OPTIONS images................................................................................................ 4 • Added SN65HVD257 FAULT pin to the PIN FUNCTIONS table ........................................................................................... 4 • Added SN65HVD257 to the Ordering Information table......................................................................................................... 4 • Added SN65HVD257 FAULT pin information to the Abs Max table ...................................................................................... 5 • Added FAULT pin information to the ROC table .................................................................................................................... 6 2 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 • changed RID - Differential input resistance value from 3 kΩ to 30 kΩ.................................................................................... 8 • Added tRXD_DTO - SN65HVD257 information ......................................................................................................................... 10 • Added Figure 4, RXD Dominant Timeout Test Circuit and Measurement ........................................................................... 11 • Added Figure 5, FAULT Test and Measurement ................................................................................................................. 11 • Added RXD Dominant Timeout (SN65HVD257) section...................................................................................................... 15 • Added FAULT pin information .............................................................................................................................................. 16 • Added footnote for SN65HVD257 function to Table 5 ......................................................................................................... 19 • Added 5-V VCC with FAULT Open-Drain Output Device (SN65HVD257) section................................................................ 21 • Added Example: Functional Safety Using the SN65HVD257 in a Redundant Physical Layer CAN Network Topology section .................................................................................................................................................................................. 24 Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 3 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 5 Device Options PART NUMBER I/O SUPPLY for RXD TXD DTO RXD DTO FAULT Output SN65HVD255 No Yes No No '251 and '1050 functional upgrade with Turbo CAN fast loop times and TXD DTO protection allowing data rates down to 10 kbps SN65HVD256 Yes Yes No No '251 and '1050 functional upgrade with Turbo CAN fast loop times and TXD DTO protection allowing data rates down to 10 kbps. RXD output level shifting through RXD supply input. SN65HVD257 No Yes Yes Yes '251 and '1050 functional upgrade with Turbo CAN fast loop times, TXD and RXD DTO protection allowing data rates down to 10 kbps and fault output pin COMMENT 6 Pin Configuration and Functions D Package 8-Pin SOIC (Top View) SN65HVD255 SN65HVD257 SN65HVD256 TXD 1 8 S TXD 1 8 S TXD 1 8 S GND 2 7 CANH GND 2 7 CANH GND 2 7 CANH VCC 3 6 CANL VCC 3 6 CANL VCC 3 6 CANL RXD 4 5 NC RXD 4 5 VRXD RXD 4 5 FAULT 5-V Supply and Fault Output 5-V Supply with RXD Level-Shifting 5-V Supply Pin Functions PIN NAME NO. TYPE TXD 1 GND 2 GND VCC 3 Supply RXD 4 O 5 Supply NC VRXD I NC FAULT DESCRIPTION CAN transmit data input (LOW for dominant and HIGH for recessive bus states) Ground connection Transceiver 5-V supply voltage CAN receive data output (LOW for dominant and HIGH for recessive bus states) SN65HVD255: No Connect SN65HVD256: RXD output supply voltage O SN65HVD257: Open drain FAULT output pin CANL 6 I/O Low level CAN bus line CANH 7 I/O High level CAN bus line S 8 I 4 Mode select: S (silent mode) select pin (active high) Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 7 Specifications 7.1 Absolute Maximum Ratings (1) (2) VCC Supply voltage VRXD RXD Output supply voltage VBUS CAN Bus I/O voltage (CANH, CANL) VLogic_Input Logic input pin voltage (TXD, S) SN65HVD256 MIN MAX UNIT –0.3 6.1 V –0.3 6 and VRXD ≤ VCC + 0.3 V –27 40 V –0.3 6 V –0.3 6 V –0.3 6 and VI ≤ VRXD + 0.3 V 12 mA VLogic_Output Logic output pin voltage (RXD) SN65HVD255, SN65HVD257 VLogic_Output Logic output pin voltage (RXD) SN65HVD256 IO(RXD) RXD (Receiver) output current IO(FAULT) FAULT output current 20 mA TJ Operating virtual junction temperature (see Power Dissipation) –40 150 °C TA Ambient temperature (see Power Dissipation) –40 125 °C (1) (2) SN65HVD257 Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltage values, except differential I/O bus voltages, are with respect to ground terminal. 7.2 ESD Ratings VALUE UNIT Human body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) V(ESD) Electrostatic discharge All pins ±2500 CAN bus pins (CANH, CANL) (2) ±12000 Charged-device model (CDM), per JEDEC specification JESD22-C101 (3) All pins ±750 Machine model All pins ±250 IEC 61400-4-2 according to GIFT-ICT CAN EMC CAN bus pins (CANH, CANL) to GND test spec (4) Pulse 1 ISO7637 Transients according to GIFT - ICT CAN EMC test spec (5) (1) (2) (3) (4) (5) ±8000 V –100 CAN bus pins (CANH, Pulse 2 CANL) Pulse 3a +75 –150 Pulse 3b +100 JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Test method based upon JEDEC Standard 22 Test Method A114, CAN bus pins stressed with respect to GND. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. IEC 61000-4-2 is a system level ESD test. Results given here are specific to the GIFT-ICT CAN EMC Test specification conditions. Different system level configurations may lead to different results. ISO7637 is a system level transient test. Results given here are specific to the GIFT-ICT CAN EMC Test specification conditions. Different system level configurations may lead to different results. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 5 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 7.3 Recommended Operating Conditions MIN MAX VCC Supply voltage 4.5 5.5 VRXD RXD supply (SN65HVD256 only) 2.8 5.5 VI or VIC CAN bus terminal voltage (separately or common mode) –2 7 VID CAN bus differential voltage -6 6 VIH Logic HIGH level input (TXD, S) 2 5.5 VIL Logic LOW level input (TXD, S) 0 0.8 IOH(DRVR) CAN BUS Driver High level output current IOL(DRVR) CAN BUS Driver Low level output current IOH(RXD) RXD pin HIGH level output current IOL(RXD) RXD pin LOW level output current IO(FAULT) FAULT pin LOW level output current TA Operational free-air temperature (see Power Dissipation) UNIT V –70 70 –2 mA 2 SN65HVD257 2 –40 125 °C 7.4 Thermal Information SN65HVD25x THERMAL METRIC (1) D (SOIC) UNIT 8 PINS RθJA Junction-to-ambient thermal resistance, High-K thermal resistance (2) 107.5 °C/W RθJC(top) Junction-to-case (top) thermal resistance 56.7 °C/W RθJB Junction-to-board thermal resistance 48.9 °C/W ψJT Junction-to-top characterization parameter 12.1 °C/W ψJB Junction-to-board characterization parameter 48.2 °C/W (1) (2) 6 For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953. The junction-to-ambient thermal resistance under natural convection is obtained in a simulation on a JEDEC-standard, High-K board, as specified in JESD51-7, in an environment described in JESD51-2a. Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 7.5 Electrical Characteristics Over recommended operating conditions, TA = –40°C to 125°C (unless otherwise noted). SN65HVD256 device VRXD = VCC. PARAMETER TEST CONDITIONS MIN TYP (1) MAX 60 85 130 180 UNIT SUPPLY CHARACTERISTICS 5-V Supply current ICC Normal Mode (Driving Dominant) See Figure 6, TXD = 0 V, RL = 50 Ω, CL = open, RCM = open, S = 0 V Normal Mode (Driving Dominant – bus fault) See Figure 6, TXD = 0 V, S = 0 V, CANH = –12 V, RL = open, CL = open, RCM = open Normal Mode (Driving Dominant) See Figure 6, TXD = 0 V, RL = open (no load), CL = open, RCM = open, S = 0 V 10 20 Normal Mode (Recessive) See Figure 6, TXD = VCC, RL = 50 Ω, CL = open, RCM = open, S=0V 10 20 Silent Mode See Figure 6, TXD = VCC, RL = 50 Ω, CL = open, RCM = open, S = VCC 2.5 5 All modes RXD Floating, TXD = 0 V IRXD RXD Supply current (SN65HVD256 only) UVVCC Undervoltage detection on VCC for protected mode VHYS(UVVCC) Hysteresis voltage on UVVCC UVRXD Undervoltage detection on VRXD for protected mode (SN65HVD256 only) VHYS(UVRXD) Hysteresis voltage on UVRXD (SN65HVD256 only) mA 3.5 500 µA 4.45 V 200 1.3 mV 2.75 80 V mV S PIN (MODE SELECT INPUT) VIH HIGH-level input voltage VIL LOW-level input voltage 2 IIH HIGH-level input leakage current S = VCC = 5.5 V IIL Low-level input leakage current S = 0 V, VCC = 5.5 V ILKG(OFF) Unpowered leakage current S = 5.5 V, VCC = 0 V, VRXD = 0 V V 7 0.8 V 100 µA –1 0 1 µA 7 35 100 µA TXD PIN (CAN TRANSMIT DATA INPUT) VIH HIGH level input voltage VIL LOW level input voltage 2 IIH HIGH level input leakage current TXD = VCC = 5.5 V –2.5 IIL Low level input leakage current TXD = 0 V, VCC = 5.5 V ILKG(OFF) Unpowered leakage current TXD = 5.5 V, VCC = 0 V, VRXD = 0 V CI Input Capacitance V 0.8 V 0 1 µA –100 –25 –7 µA –1 0 1 µA 3.5 pF RXD PIN (CAN RECEIVE DATA OUTPUT) VOH HIGH level output voltage See Figure 7, IO = –2 mA. For devices with VRXD supply VOH = 0.8 × VRXD VOL LOW level output voltage See Figure 7, IO = 2 mA ILKG(OFF) Unpowered leakage current RXD = 5.5 V, VCC = 0 V, VRXD = 0 V (1) 0.8 × VCC –1 V 0 0.4 V 1 µA All typical values are at 25°C and supply voltages of VCC = 5 V and VRXD = 5 V, RL = 60 Ω. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 7 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Electrical Characteristics (continued) Over recommended operating conditions, TA = –40°C to 125°C (unless otherwise noted). SN65HVD256 device VRXD = VCC. PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT DRIVER ELECTRICAL CHARACTERISTICS CANH VO(D) Bus output voltage (dominant) VO(R) Bus output voltage (recessive) CANL Differential output voltage (dominant) VOD(D) Differential output voltage (recessive) VOD(R) VSYM Output symmetry (dominant or recessive) (VCC – VO(CANH) – VO(CANL)) IOS(SS)_DOM Short circuit steady-state output current, Dominant See Figure 15 and Figure 6, TXD = 0 V, S = 0 V, RL = 60 Ω, CL = open, RCM = open See Figure 15 and Figure 6, TXD = VCC, VRXD = VCC, S = VCC or 0 V (2), RL = open (no load), RCM = open See Figure 15 and Figure 6, TXD = 0 V, S = 0 V, 45 Ω ≤ RL ≤ 65 Ω, CL = open, RCM = 330 Ω, –2 V ≤ VCM ≤ 7 V, 4.75 V≤ VCC ≤ 5.25 V See Figure 15 and Figure 6, TXD = 0 V, S = 0 V, 45 Ω ≤ RL ≤ 65 Ω, CL = open, RCM = 330 Ω, –2 V ≤ VCM ≤ 7 V, 4.5 V ≤ VCC ≤ 5.5 V 2.75 4.5 0.5 2.25 2 0.5 × VCC 1.5 3 V 3.2 See Figure 15 and Figure 6, TXD = VCC, S = 0 V, RL = 60 Ω, CL = open, RCM = open –0.12 0.012 See Figure 15 and Figure 6, TXD = VCC, S = 0 V, RL = open (no load), CL = open, RCM = open, –40°C ≤ TA ≤ 85°C –0.100 0.050 See Figure 15 and Figure 6, S at 0 V, RL = 60 Ω, CL = open, RCM = open –0.4 0.4 See Figure 15 and Figure 11, VCANH = 0 V, CANL = open, TXD = 0 V –160 V IOS(SS)_REC CO Output capacitance See Input capacitance to ground (CI) in the following Receiver Electrical Characteristics section of this table V mA See Figure 15 and Figure 11, VCANL = 32 V, CANH = open, TXD = 0 V See Figure 15 and Figure 11, –20 V ≤ VBUS ≤ 32 V, Where VBUS = CANH = CANL, TXD = VCC, Normal and Silent Modes V 3 1.25 Short circuit steady-state output current, Recessive V 160 –8 8 mA 900 mV RECEIVER ELECTRICAL CHARACTERISTICS Positive-going input threshold voltage, normal mode VIT+ See Figure 7, Table 5 and Table 1 VIT– Negative-going input threshold voltage, normal mode VHYS Hysteresis voltage (VIT+ - VIT–) IIOFF(LKG) Power-off (unpowered) bus input leakage current VCANH = VCANL = 5 V, VCC = 0 V, VRXD = 0 V CI Input capacitance to ground (CANH or CANL) TXD = VCC, VRXD = VCC, VI = 0.4 sin (4E6 π t) + 2.5 V 25 pF CID Differential input capacitance TXD = VCC, VRXD = VCC, VI = 0.4 sin (4E6 π t) 10 pF RID Differential input resistance RIN Input resistance (CANH or CANL) RIN(M) Input resistance matching: [1 – RIN(CANH) / RIN(CANL)] × 100% (2) 8 500 mV 125 mV 5.5 TXD = VCC = VRXD = 5 V, S = 0 V V(CANH) = V(CANL), –40°C ≤ TA ≤ 85°C µA 30 80 kΩ 15 40 kΩ –3% 3% For the bus output voltage (recessive) will be the same if the device is in normal mode with S pin LOW or if the device is in silent mode with the S pin HIGH. Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 Electrical Characteristics (continued) Over recommended operating conditions, TA = –40°C to 125°C (unless otherwise noted). SN65HVD256 device VRXD = VCC. PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT FAULT PIN (FAULT OUTPUT), SN65HVD257 ONLY ICH Output current high level FAULT = VCC, see Figure 5 ICL Output current low level FAULT = 0.4 V, see Figure 5 –10 10 5 12 µA mA 7.6 Power Dissipation THERMAL METRIC TEST CONDITIONS TYP VCC = 5 V, VRXD = 5 V, TJ = 27°C, RL = 60 Ω, S at 0 V, Input to TXD at 250 kHz, 25% duty cycle square wave, CL_RXD = 15 pF. Typical CAN operating conditions at 500 kbps with 25% transmission (dominant) rate. PD Average power dissipation UNIT 115 mW VCC = 5.5 V, VRXD = 5.5 V, TJ = 150°C, RL = 50 Ω, S at 0 V, Input to TXD at 500 kHz, 50% duty cycle square wave, CL_RXD = 15 pF. Typical high load CAN operating conditions at 1 Mbps with 50% transmission (dominant) rate and loaded network. 268 Thermal shutdown temperature Thermal shutdown hysteresis 170 °C 5 °C 7.7 Switching Characteristics over operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT DEVICE SWITCHING CHARACTERISTICS tPROP(LOOP1) Total loop delay, driver input (TXD) to receiver output (RXD), recessive to dominant tPROP(LOOP2) Total loop delay, driver input (TXD) to receiver output (RXD), dominant to recessive IMODE Mode change time, from Normal to Silent or from Silent to Normal 150 See Figure 9, S = 0 V, RL = 60 Ω, CL = 100 pF, CL_RXD = 15 pF ns 150 See Figure 8 20 µS DRIVER SWITCHING CHARACTERISTICS tpHR Propagation delay time, HIGH TXD to Driver Recessive tpLD Propagation delay time, LOW TXD to Driver Dominant tsk(p) Pulse skew (|tpHR – tpLD|) tR Differential output signal rise time 10 30 tF Differential output signal fall time 17 30 tR(10k) Differential output signal rise time, RL = 10 kΩ tF(10k) Differential output signal fall time, RL = 10 kΩ tTXD_DTO Dominant timeout (1) (1) See Figure 6, S = 0 V, RL = 60 Ω, CL = 100 pF, RCM = open 50 70 40 70 ns 10 35 See Figure 6, S = 0 V, RL = 10 kΩ, CL = 10 pF, RCM = open ns 100 See Figure 10, RL = 60 Ω, CL = open 1175 3700 µs The TXD dominant timeout (tTXD_DTO) disables the driver of the transceiver when the TXD has been dominant longer than tTXD_DTO, which releases the bus lines to recessive, thus preventing a local failure from locking the bus dominant. The driver may only transmit dominant again after TXD has been returned HIGH (recessive). While this protects the bus from local faults locking the bus dominant, it limits the minimum data rate possible. The CAN protocol allows a maximum of eleven successive dominant bits (on TXD) for the worst case, where five successive dominant bits are followed immediately by an error frame. This, along with the tTXD_DTO minimum, limits the minimum bit rate. The minimum bit rate may be calculated by: Minimum Bit Rate = 11 / tTXD_DTO = 11 bits / 1175 µs = 9.4 kbps. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 9 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Switching Characteristics (continued) over operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 70 90 ns 70 90 ns RECEIVER SWITCHING CHARACTERISTICS tpRH Propagation delay time, recessive input to high output tpDL Propagation delay time, dominant input to low output tR Output signal rise time 4 20 ns tF Output signal fall time 4 20 ns tRXD_DTO (2) Receiver dominant time out (SN65HVD257 only) See Figure 4, CL_RXD = 15 pF 4200 µs (2) See Figure 7, CL_RXD = 15 pF 1380 The RXD timeout (tRXD_DTO) disables the RXD output in the case that the bus has been dominant longer than tRXD_DTO, which releases RXD pin to the recessive state (high), thus preventing a dominant bus failure from permanently keeping the RXD pin low. The RXD pin will automatically resume normal operation once the bus has been returned to a recessive state. While this protects the protocol controller from a permanent dominant state, it limits the minimum data rate possible. The CAN protocol allows a maximum of eleven successive dominant bits (on RXD) for the worst case, where five successive dominant bits are followed immediately by an error frame. This, along with the tRXD_DTO minimum, limits the minimum bit rate. The minimum bit rate may be calculated by: Minimum Bit Rate = 11 / tRXD_DTO = 11 bits / 1380 µs = 8 kbps. 7.8 Typical Characteristics 4.8 4.4 4.6 4.2 4.4 4 VOD (V) VOD (V) 4.2 4 3.8 3.8 3.6 3.6 3.4 3.4 3.2 3.2 3 4.3 4.5 4.7 4.9 5.1 VCC (V) 5.3 5.5 3 -50 5.7 0 D001 Figure 1. Differential Output Voltage vs Supply Voltage 50 100 Temperature (qC) 150 200 D002 Figure 2. Differential Output Voltage vs Ambient Temperature 140 120 Time (ns) 100 80 60 40 20 0 40 45 50 55 60 RL - Bus Load (:) 65 70 C024 Figure 3. Typical Transceiver Loop Delay vs Bus Loading 10 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 8 Parameter Measurement Information VID(D) CANH VID RXD 0.9V 0.5V 0V VID CL_RXD CANL VO VOH RXD 50% 0V t RXD_DTO Figure 4. RXD Dominant Timeout Test Circuit and Measurement IFAULT TXD DTO FAULT RXD DTO + - Thermal Shutdown UV Lockout GND Figure 5. FAULT Test and Measurement RCM CANH TXD VCC TXD RL CL VOD VO(CANL) 50% 0V VCM VO(CANH) CANL 50% tpHR tpLD 90% RCM VOD 0.9 V 0.5 V 10% tR tF Figure 6. Driver Test Circuit and Measurement Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 11 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Parameter Measurement Information (continued) CANH 1 .5 V RXD 0 .9 V IO V ID 0 .5 V 0V VID CL_RXD CANL t pDL t pRH VO V OH 90 % V O(RXD) 50 % 10 % V OL tF tR Figure 7. Receiver Test Circuit and Measurement CANH 0V VCC TXD RL CL S 50% CANL VI S 0V tMODE RXD VO VOH CL_RXD RXD 50% VOL Figure 8. tMODE Test Circuit and Measurement Table 1. Receiver Differential Input Voltage Threshold Test INPUT 12 OUTPUT VCANH VCANL |VID| –1.1 V –2.0 V 900 mV L 7.0 V 6.1 V 900 mV L –1.5 V –2.0 V 500 mV H 7.0 V 6.5 V 500 mV H Open Open X H Submit Documentation Feedback RXD VOL VOH Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 CANH VCC TXD RL VI CL 50% TXD 0V CANL S 0V tPROP(LOOP1) RXD VO tPROP(LOOP2) VOH CL_RXD 50% RXD VOL Figure 9. TPROP(LOOP) Test Circuit and Measurement CANH TXD VIH TXD RL CL 0V VOD VOD(D) CANL 0.9 V VOD 0.5 V 0V tTXD_DTO Figure 10. TXD Dominant Timeout Test Circuit and Measurement CANH IOS 200 ms TXD IOS CANL VBUS VBUS VBUS 0V or 0V VBUS VBUS Figure 11. Driver Short Circuit Current Test and Measurement Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 13 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 9 Detailed Description 9.1 Overview The SN65HVD25x family of bus transceiver devices are compatible with the ISO 11898-2 High Speed CAN (Controller Area Network) physical layer standard. The SN65HVD25x devices are designed to interface between the differential bus lines and the CAN protocol controller at data rates up to 1 Mbps (megabits per second). 9.2 Functional Block Diagram NC / VRXD / FAULT (See Note A) 5 3 FAULT LOGIC MUX (See Note A) VCC VCC VCC OVER TEMPERATURE 7 TXD S 1 DOMINANT TIME OUT 8 6 CANH CANL MODE SELECT UNDER VOLTAGE VCC or V RXD (See Note B) RXD 4 LOGIC OUTPUT DOMINANT TIME OUT (See Note B) 2 GND A. Pin 5 function is device dependent; NC on SN65HVD255, VRXD for RXD output level-shifting device on the SN65HVD256 device, and FAULT Output on the SN65HVD257 device. B. RXD logic output is driven to 5-V VCC on 5-V only supply devices (SN65HVD255, SN65HVD257) and driven to VRXD on output level-shifting device (SN65HVD256). C. RXD (Receiver) Dominant State Time Out is a device dependent option available only on the SN65HVD257 device. 9.3 Feature Description 9.3.1 TXD Dominant Timeout (DTO) During normal mode (the only mode where the CAN driver is active), the TXD DTO circuit prevents the transceiver from blocking network communication in the event of a hardware or software failure where TXD is held dominant longer than the timeout period tTXD_DTO. The DTO circuit timer starts on a falling edge on TXD. The DTO circuit disables the CAN bus driver if no rising edge is seen before the timeout period expires, which frees the bus for communication between other nodes on the network. The CAN driver is reactivated when a recessive signal is seen on TXD pin, thus clearing the TXD DTO condition. The receiver and RXD pin still reflect the CAN bus, and the bus pins are biased to recessive level during a TXD dominant timeout. NOTE The minimum dominant TXD time allowed by the TXD DTO circuit limits the minimum possible transmitted data rate of the device. The CAN protocol allows a maximum of eleven successive dominant bits (on TXD) for the worst case, where five successive dominant bits are followed immediately by an error frame. This, along with the tTXD_DTO minimum, limits the minimum data rate. Calculate the minimum transmitted data rate by: Minimum Data Rate = 11 / tTXD_DTO. 14 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 Feature Description (continued) 9.3.2 RXD Dominant Timeout (SN65HVD257) The SN65HVD257 device has a RXD dominant timeout (RXD DTO) circuit that prevents a bus stuck dominant fault from permanently driving the RXD output dominant (low) when the bus is held dominant longer than the timeout period tRXD_DTO. The RXD DTO timer starts on a falling edge on RXD (bus going dominant). If no rising edge (bus returning recessive) is seen before the timeout constant of the circuit expires (tRXD_DTO), the RXD pin returns high (recessive). The RXD output is reactivated to mirror the bus receiver output when a recessive signal is seen on the bus, clearing the RXD dominant timeout. The CAN bus pins are biased to the recessive level during a RXD DTO. NOTE The minimum dominant RXD time allowed by the RXD DTO limits the minimum possible received data rate of the device. The CAN protocol allows a maximum of eleven successive dominant bits for the worst case transmission, where five successive dominant bits are followed immediately by an error frame. This, along with the tRXD_DTO minimum, limits the minimum data rate. The minimum received data rate may be calculated by: Minimum Data Rate = 11 / tRXD_DTO. 9.3.3 Thermal Shutdown If the junction temperature of the device exceeds the thermal shut down threshold, the device turns off the CAN driver circuits thus blocking the TXD to bus transmission path. The shutdown condition is cleared when the junction temperature drops below the thermal shutdown temperature of the device. NOTE During thermal shutdown the CAN bus drivers turn off; thus, no transmission is possible from TXD to the bus. The CAN bus pins are biased to recessive level during a thermal shutdown, and the receiver to RXD path remains operational. 9.3.4 Undervoltage Lockout The supply pins have undervoltage detection that places the device in protected mode, which protects the bus during an undervoltage event on either the VCC or VRXD supply pins. Table 2. Undervoltage Lockout 5-V Only Devices (SN65HVD255 and SN65HVD257) VCC DEVICE STATE BUS OUTPUT RXD GOOD Normal Per Device State and TXD Mirrors Bus BAD Protected High Impedance High Impedance (3-state) Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 15 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Table 3. Undervoltage Lockout 5 V and VRXD Device (SN65HVD256) VCC VRXD DEVICE STATE BUS OUTPUT RXD GOOD GOOD Normal Per Device State and TXD Mirrors Bus BAD GOOD Protected High Impedance High (Recessive) GOOD BAD Protected Recessive High Impedance (3-state) BAD BAD Protected High Impedance High Impedance (3-state) NOTE After an undervoltage condition is cleared and the supplies have returned to valid levels, the device typically resumes normal operation in 300 µs. 9.3.5 FAULT Pin (SN65HVD257) If one or more of the faults (TXD dominant timeout, RXD dominant timeout, thermal shutdown or undervoltage lockout) occurs, the FAULT pin (open-drain) turns off, resulting in a high level when externally pulled up to VCC or I/O supply. VCC or VIO µP FAULT Input FAULT TXD DTO RXD DTO Thermal Shutdown GND UV Lockout Figure 12. FAULT Pin Function Diagram and Application 16 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 TXD fault stuck dominant, example PCB failure or bad software TXD (driver) tTXD_DTO Fault is repaired & transmission capability restored Driver disabled freeing bus for other nodes %XVZRXOGEH³VWXFNGRPLQDQW´EORFNLQJFRPPXQLFDWLRQIRUWKH whole network but TXD DTO prevents this and frees the bus for communication after the time tTXD_DTO. Normal CAN communication CAN Bus Signal tTXD_DTO Communication from other bus node(s) Communication from repaired node FAULT is signaled to link layer / protocol. Fault indication is removed. FAULT (HVD257) RXD (receiver) Communication from other bus node(s) Communication from local node Communication from repaired local node Figure 13. Example Timing Diagram for TXD DTO and FAULT Pin Bus Fault stuck dominant , example CANH short to supply =5V and CAN L short to GND . Fault is repaired and normal communication returns SN65HVD255 SN65HVD256 CAN Bus Signal SN65HVD257 CAN PHY With RXD DTO AND FAULT CAN PHY CAN BUS Normal CAN communication RXD (receiver) RXD will also be “stuck dominant” blocking alternative communication paths RXD (reciever) t RXD_DTO RXD output is returned recessive (high) and FAULT is signaled to μP and link layer / protocol. RXD mirrors bus FAULT cleared signal is given FAULT Figure 14. Example Timing Diagram for Devices With and Without RXD DTO and FAULT Pin Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 17 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 9.3.6 Unpowered Device The SN65HVD25x device is designed to be an ideal passive or no load to the CAN bus if it is unpowered. The bus pins (CANH, CANL) have extremely low leakage currents when the device is unpowered, so they will not load down the bus. This is critical if some nodes of the network will be unpowered while the rest of the of network remains in operation. The logic pins also have extremely low leakage currents when the device is unpowered to avoid loading down other circuits that may remain powered. 9.3.7 Floating Pins The device has internal pullups and pulldowns on critical pins to place the device into known states if the pins float. The TXD pin is pulled up to VCC to force a recessive input level if the pin floats. The S pin is pulled down to GND to force the device into normal mode if the pin floats. 9.3.8 CAN Bus Short-Circuit Current Limiting The SN65HVD25x device has several protection features that limit the short circuit current when a CAN bus line is shorted. These features include driver current limiting (dominant and recessive). The device has TXD dominant state time out to prevent permanent higher short circuit current of the dominant state during a system fault. During CAN communication, the bus switches between dominant and recessive states with the data and control fields bits; thus the short circuit current may be viewed either as the instantaneous current during each bus state or as a DC average current. For system current (power supply) and power considerations in the termination resistors and common-mode choke ratings, use the average short circuit current. Determine the ratio of dominant and recessive bits by the data in the CAN frame plus the following factors of the protocol and PHY that force either recessive or dominant at the following times: • • • • Control fields with set bits Bit stuffing Interframe space TXD dominant time out (fault case limiting) These factors ensure a minimum recessive amount of time on the bus even if the data field contains a high percentage of dominant bits. 18 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 The short circuit current of the bus depends on the ratio of recessive to dominant bits and their respective short circuit currents. The average short circuit current may be calculated with Equation 1. IOS(AVG) = %Transmit × [(%REC_Bits × IOS(SS)_REC) + (%DOM_Bits × IOS(SS)_DOM)] + [%Receive × IOS(SS)_REC] (1) where: IOS(AVG) is the average short circuit current %Transmit is the percentage the node is transmitting CAN messages %Receive is the percentage the node is receiving CAN messages %REC_Bits is the percentage of recessive bits in the transmitted CAN messages %DOM_Bits is the percentage of dominant bits in the transmitted CAN messages IOS(SS)_REC is the recessive steady state short circuit current IOS(SS)_DOM is the dominant steady state short circuit current NOTE Consider the short circuit current and possible fault cases of the network when sizing the power ratings of the termination resistance and other network components. 9.4 Device Functional Modes Table 4. Driver Function Table INPUTS DEVICE S (1) (2) L or Open All Devices H (1) (2) (3) OUTPUTS TXD (1) (3) CANH (1) CANL (1) DRIVEN BUS STATE L H L Dominant H or Open Z Z Recessive X Z Z Recessive H = high level, L = low level, X= irrelevant, Z = common mode (recessive) bias to VCC / 2. See Figure 15 and Figure 16 for bus state and common mode bias information. Devices have an internal pulldown to GND on S pin. If S pin is open the pin will be pulled low and the device will be in normal mode. Devices have an internal pullup to VCC on TXD pin. If the TXD pin is open the pin will be pulled high and the transmitter will remain in recessive (nondriven) state. Table 5. Receiver Function Table DEVICE MODE Normal or Silent (1) (2) CAN DIFFERENTIAL INPUTS VID = VCANH – VCANL BUS STATE RXD PIN (1) VID ≥ 0.9 V Dominant L (2) 0.5 V < VID < 0.9 V ? ? VID ≤ 0.5 V Recessive H Open (VID ≈ 0 V) Open H H = high level, L = low level, ? = indeterminate. RXD output remains dominant (low) as long as the bus is dominant. On the SN65HVD257 device with RXD dominant timeout, when the bus has been dominant longer than the dominant timeout, tRXD_DTO, the RXD pin will return recessive (high). See RXD Dominant Timeout (SN65HVD257) for a description of behavior during receiving a bus stuck dominant condition. 9.4.1 Operating Modes The device has two main operating modes: normal mode and silent mode. Operating mode selection is made via the S input pin. Table 6. Operating Modes (1) S Pin MODE DRIVER RECEIVER RXD PIN LOW Normal Mode Enabled (ON) Enabled (ON) Mirrors Bus State (1) HIGH Silent Mode Disabled (OFF) Enabled (ON) Mirrors Bus State Mirrors bus state: low if CAN bus is dominant, high if CAN bus is recessive. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 19 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 9.4.2 Can Bus States The CAN bus has two states during powered operation of the device: dominant and recessive. A dominant bus state is when the bus is driven differentially, corresponding to a logic low on the TXD and RXD pin. A recessive bus state is when the bus is biased to VCC / 2 via the high-resistance internal input resistors RIN of the receiver, corresponding to a logic high on the TXD and RXD pins. See Figure 15 and Figure 16. Typical Bus Voltage (V) Normal & Silent Mode 4 CANH 3 Vdiff(D) 2 Vdiff(R) CANL 1 Recessive Logic H Dominant Logic L Recessive Logic H Time, t Figure 15. Bus States (Physical Bit Representation) CANH VCC/2 RXD CANL Figure 16. Simplified Recessive Common Mode Bias and Receiver 9.4.3 Normal Mode Select the normal mode of device operation by setting S low. The CAN driver and receiver are fully operational and CAN communication is bidirectional. The driver is translating a digital input on TXD to a differential output on CANH and CANL. The receiver is translating the differential signal from CANH and CANL to a digital output on RXD. 9.4.4 Silent Mode Activate silent mode (receive only) by setting S high. The CAN driver is turned off while the receiver remains active and RXD outputs the received bus state. NOTE Silent mode may be used to implement babbling idiot protection, to ensure that the driver does not disrupt the network during a local fault. Silent mode may also be used in redundant systems to select or de-select the redundant transceiver (driver) when needed. 20 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 9.4.5 Digital Inputs and Outputs 9.4.5.1 5-V VCC Only Devices (SN65HVD255 and SN65HVD257) The 5-V VCC device is supplied by a single 5-V rail. The digital inputs are 5-V and 3.3-V compatible. The SN65HVD255 and SN65HVD257 devices have a 5-V (VCC) level RXD output. TXD is internally pulled up to VCC and S is internally pulled down to GND. NOTE TXD is internally pulled up to VCC and the S pin is internally pulled down to GND. However, the internal bias may only put the device into a known state if the pins float. The internal bias may be inadequate for system-level biasing. TXD pullup strength and CAN bit timing require special consideration when the SN65HVD25x devices are used with an open-drain TXD output on the CAN controller. An adequate external pullup resistor must be used to ensure that the CAN controller output of the μP maintains adequate bit timing input to the SN65HVD25x devices. 9.4.5.2 5-V VCC With VRXD RXD Output Supply Devices (SN65HVD256) This device is a 5-V VCC CAN transceiver with a separate supply for the RXD output, VRXD. The digital inputs are 5-V and 3.3-V compatible. The SN65HVD256 device has a VRXD level RXD output. TXD remains weakly pulled up to VCC. NOTE On device versions with a VRXD supply that shifts the RXD output level, the input pins of the device remain the same. TXD remains weakly pulled up to VCC internally. Thus, a small IIH current flows if the TXD input is used below VCC levels. 9.4.5.3 5-V VCC with FAULT Open-Drain Output Device (SN65HVD257) The SN65HVD257 device has a FAULT output pin (open-drain). FAULT must be pulled up to VCC or I/O supply level through an external resistor. NOTE Because the FAULT output pin is open-drain, it actively pulls down when there is no fault and becomes high-impedance when a fault condition is detected. An external pullup resistor to the VCC or I/O supply of the system must be used to pull the pin high to indicate a fault to the host microprocessor. The open-drain architecture makes the fault pin compatible with 3.3-V and 5-V I/O-level systems. The pullup current, selected by the pullup resistance value, must be as low as possible while achieving the desired voltage level output in the system with margin against noise. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 21 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 10 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 10.1 Application Information 10.1.1 Bus Loading, Length, and Number of Nodes The ISO 11898 standard states that a CAN bus should have a maximum of 30 nodes, be less than 40 meters from end to end, and should have no stubs greater than 0.3 meters. However, with careful design, users can have longer cables, longer stub lengths, and many more nodes to a bus. A large number of nodes requires a transceiver with high input impedance, such as the SN65HVD25x family devices. Many CAN organizations and standards have scaled the use of CAN for applications outside the original ISO11898 standard. They have made system level trade-offs for data rate, cable length, and parasitic loading of the bus. Examples of some of these specifications are: ARINC825, CANopen, DeviceNet, and NMEA200. A CAN network design is a series of trade-offs, but these devices operate over wide common-mode range. In ISO11898-2, the driver differential output is specified with a 60-Ω load (the two 120-Ω termination resistors in parallel) and the differential output must be greater than 1.5 V. The SN65HVD25x devices are specified to meet the 1.5-V requirement with a 45-Ω load incorporating the worst case including parallel transceivers. The differential input resistance of the SN65HVD25x devices is a minimum of 30 KΩ. If 167 SN65HVD25x family transceivers are in parallel on a bus, this is equivalent to a 180-Ω differential load worst case. That transceiver load of 180 Ω in parallel with the 60 Ω gives a total 45 Ω. Therefore, the SN65HVD25x family theoretically supports over 167 transceivers on a single bus segment with margin to the 1.2-V minimum differential input at each node. However, CAN network design margin must be given for signal loss across the system and cabling, parasitic loadings, network imbalances, ground offsets, and signal integrity; thus a practical maximum number of nodes is typically much lower. Bus length may also be extended beyond the original ISO11898 standard of 40 m by careful system design and data-rate tradeoffs. For example, CAN open network design guidelines allow the network to be up to 1 km with changes in the termination resistance, cabling, less than 64 nodes, and a significantly lowered data rate. This flexibility in CAN network design is one of the key strengths of the various extensions and additional standards that have been built on the original ISO11898 CAN standard. In using this flexibility comes the responsibility of good network design and balancing these tradeoffs. 22 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 10.2 Typical Applications 10.2.1 Typical 5-V Microcontroller Application VIN VIN VOUT 5-V Voltage Regulator (e.g.TPSxxxx) VCC VCC 3 Port x S 7 CANH 8 SN65HVD255 5-V MCU CAN Transceiver RXD TXD RXD TXD 4 1 5 NC 6 2 CANL GND Figure 17. Typical 5-V Application 10.2.1.1 Design Requirements 10.2.1.1.1 CAN Termination The ISO11898 standard specifies the interconnect to be a twisted-pair cable (shielded or unshielded) with 120-Ω characteristic impedance (ZO). Resistors equal to the characteristic impedance of the line must be used to terminate both ends of the cable to prevent signal reflections. Unterminated drop lines (stubs) connecting nodes to the bus must be kept as short as possible to minimize signal reflections. The termination may be on the cable or in a node, but if nodes may be removed from the bus, the termination must be carefully placed so that it is not removed from the bus. Node 1 Node 2 Node 3 MCU or DSP MCU or DSP MCU or DSP CAN Controller CAN Controller CAN Controller CAN Transceiver CAN Transceiver CAN Transceiver Node n (with termination) MCU or DSP CAN Controller CAN Transceiver RTERM RTERM Figure 18. Typical CAN Bus Termination may be a single 120-Ω resistor at the end of the bus either on the cable or in a terminating node. If filtering and stabilization of the common mode voltage of the bus is desired, then split termination may be used (see Figure 19). Split termination improves the electromagnetic emissions behavior of the network by eliminating fluctuations in the bus common-mode voltages at the start and end of message transmissions. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 23 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Typical Applications (continued) Standard Termination CANH Split Termination CANH RTERM/2 CAN CAN Transceiver RTERM Transceiver CSPLIT RTERM/2 CANL CANL Figure 19. CAN Bus Termination Concepts 10.2.1.2 Detailed Design Procedure 10.2.1.2.1 Example: Functional Safety Using the SN65HVD257 in a Redundant Physical Layer CAN Network Topology CAN is a standard linear bus topology using 120-Ω twisted-pair cabling. The SN65HVD257 CAN device includes several features to use the CAN physical layer in nonstandard topologies with only one CAN link layer controller (μP) interface. This allows much greater flexibility in the physical topology of the bus while reducing the digital controller and software costs. The combination of RXD DTO and the FAULT output allows great flexibility, control, and monitoring of these applications. A simple example of this flexibility is to use two SN65HVD257 devices in parallel with an AND gate to achieve redundancy (parallel) of the physical layer (cabling and PHYs) in a CAN network. For the CAN bit-wise arbitration to work, the RXD outputs of the transceivers must connect through AND gate logic so that a dominant bit (low) from any of the branches is received by the link layer logic (μP) and appears to the link layer and above as a single physical network. The RXD DTO feature prevents a bus stuck dominant fault in a single branch from taking down the entire network by forcing the RXD pin for the transceivers on the branch with the fault back to the recessive after the tRXD_DTO time. The remaining branch of the network continues to function. The FAULT pin of the transceivers on the branch with the fault indicates this through the FAULT output to their host processors, which diagnose the failure condition. The S pin (silent mode pin) may be used to put a branch in silent mode to check each branch for other faults. Therefore, it is possible to implement a robust and redundant CAN network topology in a very simple and low-cost manner. These concepts can be expanded into more complicated and flexible CAN network topologies to solve various system-level challenges with a networked infrastructure. 24 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 Typical Applications (continued) μP μP SN65HVD 257 A1 ~~ ~ ~ SN65HVD 257 B1 RX D_A RXD_B SN65HVD 257 A2 RX D TXD S_A FAULT_ A S_B RX D_A RXD_B SN65HVD 257 B2 FAULT_ B RX D SN65HVD 257 A3 TXD S_A FAULT_ A S_B SN65 HVD 257 B3 RX D_A RXD_B RXD_A RXD_B SN65 HVD257 An FAULT_ B RX D TXD S_A FAULT_ A S_B FAULT_ B RXD TXD S_A FAULT_A S_B FAULT_B SN65HVD 257 Bn μP μP A. CAN nodes with termination are PHY A, PHY B, PHY An and PHY Bn. B. RXD DTO prevents a single branch-stuck-dominant condition from blocking the redundant branch through the AND logic on RXD. The transceivers signal a received bus stuck dominant fault through the FAULT pin. The system detects which branch is stuck dominant and issues a system warning. Other network faults on a single branch that appear as recessive (not blocking the redundant network) may be detected through diagnostic routines and using the Silent Mode of the PHYs to use only one branch at a time for transmission during diagnostic mode. This combination allows robust fault detection and recovery within single branches so that they may be repaired and again provide redundancy of the physical layer. Figure 20. Typical Redundant Physical Layer Topology Using the SN65HVD257 Device 10.2.1.3 Application Curves Figure 21 shows the typical loop delay through the transceiver based on the differential resistive load between CANH and CANL. Figure 21. Typical TXD to RXD Loop Delay Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 25 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com Typical Applications (continued) 10.2.2 Typical 3.3-V Microcontroller Application The SN65HVD256 device has a second supply voltage pin used for level shifting the input and output pins. This can be used for applications where there is a 3.3-V micrcontroller and a 5-V CAN transceiver. VIN VIN VOUT 5-V Voltage Regulator (e.g. TPSxxxx) VCC VCC 3 Port x S SN65HVD256 CAN Transceiver VOUT RXD 3-V Voltage Regulator (e.g. TPSxxxx) CANH 8 3-V MCU VIN 7 TXD RXD TXD 4 1 5 VRXD 6 2 CANL GND Figure 22. Typical 3.3-V Application 26 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 SN65HVD255, SN65HVD256, SN65HVD257 www.ti.com SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 11 Power Supply Recommendations To ensure reliable operation at all data rates and supply voltages, each supply must be decoupled with a 100-nF ceramic capacitor located as close as possible to the supply pins. The TPS76350 device is a linear voltage regulator suitable for the 5-V supply rail. 12 Layout 12.1 Layout Guidelines For the PCB design to be successful, start with the design of the protection and filtering circuitry because ESD and EFT transients have a wide frequency bandwidth from approximately 3-MHz to 3-GHz and high frequency layout techniques must be applied during PCB design. On chip IEC ESD protection is good for laboratory and portable equipment but is usually not sufficient for EFT and surge transients occurring in industrial environments. Therefore, robust and reliable bus node design requires the use of external transient protection devices at the bus connectors. Placement at the connector also prevents these harsh transient events from propagating further into the PCB and system. Use VCC and ground planes to provide low inductance. NOTE High frequency current follows the path of least inductance and not the path of least resistance. Design the bus protection components in the direction of the signal path. Do not force the transient current to divert from the signal path to reach the protection device. Below is a list of layout recommendations when designing a CAN transceiver into an application. • Transient Protection on CANH and CANL: Transient Voltage Suppression (TVS) and capacitors (D1, C5 and C7 shown in Figure 23) can be used to protect the system level transients like EFT, IEC ESD, and Surge. These devices must be placed as close to the connector as possible. This prevents the transient energy and noise from penetrating into other nets on the board. • Bus Termination on CANH and CANL: Figure 23 shows split termination where the termination is split into two resistors, R5 and R6, with the center or split tap of the termination connected to ground through capacitor C6. Split termination provides common mode filtering for the bus. When termination is placed on the board instead of directly on the bus, care must be taken to ensure the terminating node is not removed from the bus, as this causes signal integrity issues if the bus is not properly terminated on both ends. • Decoupling Capacitors on VCC and VRXD: Bypass and bulk capacitors must be placed as close as possible to the supply pins of transceiver (examples are C2, C3, C5, and C6). • Ground and power connections: Use at least two vias for VCC, VIO, and ground connections of bypass capacitors and protection devices to minimize trace and via inductance. • Digital inputs and outputs: To limit current of digital lines, serial resistors may be used. Examples are R1, R2, R3, R4, and R5. • Filtering noise on digital inputs and outputs: To filter noise on the digital I/O lines, a capacitor may be used close to the input side of the I/O as shown by C1 and C4. • External pull-up resistors on input and output pins: Because the internal pullup and pulldown biasing of the device is weak for floating pins, an external 1-kΩ to 10-kΩ pullup or pulldown resistor must be used to bias the state of the pins during transient events. • Fault Output Pin (SN65HVD257 only): Because the FAULT output pin is an open drain output, an external pullup resistor is required to pull the pin voltage high for normal operation (R5). • VRXD Supply (SN65HVD256 only): The SN65HVD256 device will need additional bypass capacitors for the VRXD supply shown with C5 and C6. • TXD input pin: If an open-drain host processor is used to drive the TXD pin of the device, an external pullup resistor between 1 kΩ and 10 kΩ must be used to help drive the recessive input state of the device (weak internal pullup resistor). Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 27 SN65HVD255, SN65HVD256, SN65HVD257 SLLSEA2D – DECEMBER 2011 – REVISED MAY 2015 www.ti.com 12.2 Layout Example S R2 GND C4 TXD R4 R1 8 1 C1 VCC orVRXD C8 GND GND 2 C7 SN65HVD25x 6 4 5 R8 C9 3 J1 D1 U1 C3 C2 VCC R7 7 U1 GND RXD R3 VRXD C6 C5 GND R5 R6 FAULT VCC or VRXD Figure 23. Layout Example 13 Device and Documentation Support 13.1 Related Links The table below lists quick access links. Categories include technical documents, support and community resources, tools and software, and quick access to sample or buy. Table 7. Related Links PARTS PRODUCT FOLDER SAMPLE & BUY TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY SN65HVD255 Click here Click here Click here Click here Click here SN65HVD256 Click here Click here Click here Click here Click here SN65HVD257 Click here Click here Click here Click here Click here 13.2 Trademarks All trademarks are the property of their respective owners. 13.3 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 13.4 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 14 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. 28 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: SN65HVD255 SN65HVD256 SN65HVD257 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) SN65HVD255D ACTIVE SOIC D 8 75 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD255 SN65HVD255DR ACTIVE SOIC D 8 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD255 SN65HVD256D ACTIVE SOIC D 8 75 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD256 SN65HVD256DR ACTIVE SOIC D 8 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD256 SN65HVD257D ACTIVE SOIC D 8 75 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD257 SN65HVD257DR ACTIVE SOIC D 8 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 125 HVD257 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
SN65HVD257D 价格&库存

很抱歉,暂时无法提供与“SN65HVD257D”相匹配的价格&库存,您可以联系我们找货

免费人工找货