SN54ALS832A, SN54AS832B, SN74ALS832A, SN74AS832B
HEX 2-INPUT OR DRIVERS
SDAS017C – DECEMBER 1982 – REVISED JANUARY 1995
SN54ALS832A, SN54AS832B . . . J PACKAGE
SN74ALS832A, SN74AS832B . . . DW OR N PACKAGE
(TOP VIEW)
High Capacitive-Drive Capability
′ALS832A Has Typical Delay Time of 4.8 ns
(CL = 50 pF) and Typical Power Dissipation
of 4.5 mW Per Gate
′AS832B Has Typical Delay Time of 3.2 ns
(CL = 50 pF) and Typical Power Dissipation
of Less Than 13 mW Per Gate
Package Options Include Plastic
Small-Outline (DW) Packages, Ceramic
Chip Carriers (FK), and Standard Plastic (N)
and Ceramic (J) 300-mil DIPs
•
•
1A
1B
1Y
2A
2B
2Y
3A
3B
3Y
GND
description
These devices contain six independent 2-input
OR drivers. They perform the Boolean functions
Y = A + B or Y = A • B in positive logic.
OUTPUT
Y
H
X
H
X
H
H
L
L
L
logic symbol†
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
1
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
VCC
6B
6A
6Y
5B
5A
5Y
4B
4A
4Y
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
6A
6Y
5B
5A
5Y
3Y
GND
4Y
4A
4B
B
2
1Y
1B
1A
VCC
2A
2B
2Y
3A
3B
FUNCTION TABLE
(each driver)
INPUTS
20
SN54ALS832A, SN54AS832B . . . FK PACKAGE
(TOP VIEW)
The SN54ALS832A and SN54AS832B are
characterized for operation over the full military
temperature range of – 55°C to 125°C. The
SN74ALS832A
and
SN74AS832B
are
characterized for operation from 0°C to 70°C.
A
1
6B
•
•
logic diagram (positive logic)
≥1
4
3
1Y
1B
6
5
2Y
9
3Y
11
4Y
15
16
4A
4B
14
5Y
18
19
3A
3B
12
13
2A
2B
7
8
1A
17
5A
5B
6Y
6A
6B
1
2
4
3
6
5
7
9
8
12
11
13
15
14
16
18
19
17
1Y
2Y
3Y
4Y
5Y
6Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Copyright 1995, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS832A, SN54AS832B, SN74ALS832A, SN74AS832B
HEX 2-INPUT OR DRIVERS
SDAS017C – DECEMBER 1982 – REVISED JANUARY 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS832A . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS832A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS832A
SN74ALS832A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.7
0.8
V
High-level output current
– 12
– 15
mA
IOL
TA
Low-level output current
12
24
mA
70
°C
High-level input voltage
2
Operating free-air temperature
2
– 55
125
V
V
0
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = –18 mA
IOH = – 0.4 mA
VCC = 4.5 V
IOH = – 3 mA
IOH = – 12 mA
VOL
VCC = 4
4.5
5V
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
IIL
IO§
VCC = 5.5 V,
VCC = 5.5 V,
ICCH
ICCL
VCC = 5.5 V,
VCC = 5.5 V,
SN54ALS832A
TYP‡
MAX
MIN
–1.5
VCC – 2
2.4
–1.5
VCC – 2
2.4
3.2
3.2
UNIT
V
V
2
IOH = – 15 mA
IOL = 12 mA
2
0.25
IOL = 24 mA
VI = 7 V
VI = 2.7 V
VI = 0.4 V
VO = 2.25 V
VI = 4.5 V
SN74ALS832A
TYP‡
MAX
MIN
0.4
0.25
0.4
0.35
0.5
0.1
0.1
mA
20
20
µA
– 0.1
– 20
– 112
– 30
– 0.1
mA
– 112
mA
mA
6
9
6
9
9.5
16
9.5
16
mA
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
2
VI = 0
V
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS832A, SN54AS832B, SN74ALS832A, SN74AS832B
HEX 2-INPUT OR DRIVERS
SDAS017C – DECEMBER 1982 – REVISED JANUARY 1995
switching characteristics (see Figure 1)
PARAMETER
tPLH
tPHL
FROM
(INPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
SN54ALS832A SN74ALS832A
TO
(OUTPUT)
A or B
MIN
MAX
MIN
MAX
1
13
2
9
1
11
1
8
Y
UNIT
ns
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54AS832B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74AS832B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions§
SN54AS832B
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
High-level input voltage
SN74AS832B
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
2
High-level output current
IOL
Low-level output current
TA
Operating free-air temperature
– 55
§ These high sink- or source-current devices are not recommended for use above 40 MHz.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2
UNIT
V
V
0.8
0.8
V
– 40
– 48
mA
40
48
mA
70
°C
125
0
3
SN54ALS832A, SN54AS832B, SN74ALS832A, SN74AS832B
HEX 2-INPUT OR DRIVERS
SDAS017C – DECEMBER 1982 – REVISED JANUARY 1995
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
SN54AS832B
TYP†
MAX
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = –18 mA
IOH = – 2 mA
VCC = 4.5 V
IOH = – 3 mA
IOH = – 40 mA
VOL
VCC = 4
4.5
5V
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
IIL
IO‡
VCC = 5.5 V,
VCC = 5.5 V,
ICCH
ICCL
VCC = 5.5 V,
VCC = 5.5 V,
MIN
SN74AS832B
TYP†
MAX
MIN
–1.2
VCC – 2
2.4
–1.2
VCC – 2
2.4
3.2
3.2
V
V
2
IOH = – 48 mA
IOL = 40 mA
UNIT
2
0.25
IOL = 48 mA
VI = 7 V
0.5
0.35
VI = 2.7 V
VI = 0.4 V
0.5
0.1
0.1
mA
20
20
µA
– 0.5
VO = 2.25 V
VI = 4.5 V
– 50
VI = 0
V
– 200
– 50
– 0.5
mA
– 200
mA
mA
11
17
11
17
22
36
22
36
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX§
SN54AS832B
tPLH
tPHL
A or B
Y
SN74AS832B
MIN
MAX
MIN
MAX
1
7.5
1
6.3
1
7
1
6.3
§ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
ns
SN54ALS832A, SN54AS832B, SN74ALS832A, SN74AS832B
HEX 2-INPUT OR DRIVERS
SDAS017C – DECEMBER 1982 – REVISED JANUARY 1995
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
From Output
Under Test
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
Data
Input
tw
th
tsu
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
[3.5 V
1.3 V
tPHZ
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOL
0.3 V
VOH
1.3 V
0.3 V
[0 V
3.5 V
1.3 V
Input
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
PACKAGE OPTION ADDENDUM
www.ti.com
12-Dec-2022
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
Samples
(4/5)
(6)
5962-88523012A
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
596288523012A
SNJ54AS
832BFK
8414501RA
ACTIVE
CDIP
J
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
8414501RA
SNJ54ALS832AJ
Samples
SN54ALS832AJ
ACTIVE
CDIP
J
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
SN54ALS832AJ
Samples
SN74ALS832ADW
ACTIVE
SOIC
DW
20
25
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
ALS832A
Samples
SN74ALS832AN
ACTIVE
PDIP
N
20
20
RoHS &
Non-Green
NIPDAU
N / A for Pkg Type
0 to 70
SN74ALS832AN
Samples
SN74AS832BDW
ACTIVE
SOIC
DW
20
25
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
AS832B
Samples
SN74AS832BDWR
ACTIVE
SOIC
DW
20
2000
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
AS832B
Samples
SN74AS832BN
ACTIVE
PDIP
N
20
20
RoHS &
Non-Green
NIPDAU
N / A for Pkg Type
0 to 70
SN74AS832BN
Samples
SNJ54ALS832AJ
ACTIVE
CDIP
J
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
8414501RA
SNJ54ALS832AJ
Samples
SNJ54AS832BFK
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
596288523012A
SNJ54AS
832BFK
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Addendum-Page 1
Samples
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
12-Dec-2022
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of