0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SN74AS169ADRE4

SN74AS169ADRE4

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    SOIC16_150MIL

  • 描述:

    IC COUNTER BIN SYNC 4BIT 16-SOIC

  • 数据手册
  • 价格&库存
SN74AS169ADRE4 数据手册
              SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 • • • • • SN54ALS169B, SN54AS169A . . . J PACKAGE SN74ALS169B, SN74AS169A . . . D OR N PACKAGE (TOP VIEW) Fully Synchronous Operation for Counting and Programming Internal Carry Look-Ahead Circuitry for Fast Counting Carry Output for n-Bit Cascading Fully Independent Clock Circuit Package Options Include Plastic Small-Outline (D) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs U/D CLK A B C D ENP GND 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC RCO QA QB QC QD ENT LOAD description These synchronous 4-bit up/down binary presettable counters feature an internal carry look-ahead circuitry for cascading in high-speed counting applications. Synchronous operation is provided by having all flip-flops clocked simultaneously so that the outputs change coincident with each other when so instructed by the count-enable (ENP, ENT) inputs and internal gating. This mode of operation eliminates the output counting spikes normally associated with asynchronous (ripple-clock) counters. A buffered clock (CLK) input triggers the four flip-flops on the rising (positive-going) edge of the clock waveform. CLK U/D NC VCC RCO SN54ALS169B, SN54AS169A . . . FK PACKAGE (TOP VIEW) 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 QA QB NC QC QD ENP GND NC LOAD ENT A B NC C D These counters are fully programmable; that is, they may be preset to either level. The load-input circuitry allows loading with the carry-enable output of cascaded counters. Because loading is synchronous, setting up a low level at the load (LOAD) input disables the counter and causes the outputs to agree with the data inputs after the next clock pulse. NC − No internal connection The internal carry look-ahead circuitry provides for cascading counters for n-bit synchronous application without additional gating. ENP and ENT inputs and a ripple-carry output (RCO) are instrumental in accomplishing this function. Both ENP and ENT must be low to count. The direction of the count is determined by the level of the up/down (U/D) input. When U/D is high, the counter counts up; when low, it counts down. ENT is fed forward to enable RCO. RCO, thus enabled, produces a low-level pulse while the count is zero (all inputs low) counting down or maximum (15) counting up. This low-level overflow ripple-carry pulse can be used to enable successive cascaded stages. Transitions at ENP or ENT are allowed regardless of the level of the clock input. All inputs are diode clamped to minimize transmission-line effects, thereby simplifying system design. These counters feature a fully independent clock circuit. Changes at control inputs (ENP, ENT, LOAD, or U/D) that modify the operating mode have no effect on the contents of the counter until clocking occurs. The function of the counter (whether enabled, disabled, loading, or counting) is dictated solely by the conditions meeting the stable setup and hold times. The SN54ALS169B and SN54AS169A are characterized for operation over the full military temperature range of −55°C to 125°C. The SN74ALS169B and SN74AS169A are characterized for operation from 0°C to 70°C. Copyright  1994, Texas Instruments Incorporated   !"#$ % &'!!($ #%  )'*+&#$ ,#$(!,'&$% &!" $ %)(&&#$% )(! $.( $(!"%  (/#% %$!'"($% %$#,#!, 0#!!#$1- !,'&$ )!&(%%2 ,(% $ (&(%%#!+1 &+',( $(%$2  #++ )#!#"($(!%- • DALLAS, TEXAS 75265 • HOUSTON, TEXAS 77251−1443 POST OFFICE BOX 655303 POST OFFICE BOX 1443 2−1               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 logic symbol† LOAD 9 1 U/D ENT ENP CLK 10 7 2 CTRDIV16 M1 [LOAD] M2 [COUNT] M3 [UP] M4 [DOWN] 3,5CT=15 4,5CT=0 G5 15 RCO G6 2,3,5,6+/C7 2,4,5,6 − A B C D 3 1 1, 7D 4 2 5 4 6 8 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages. 2−2 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 14 13 12 11 QA QB QC QD               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 logic diagram (positive logic) LOAD U/D ENT ENP 9 1 15 RCO 10 7 C1 CLK A 2 1D 14 QA 3 C1 1D B 13 QB 4 C1 1D C 12 QC 5 C1 1D D 11 QD 6 Pin numbers shown are for the D, J, and N packages. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 2−3               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 typical load, count, and inhibit sequences The following sequence is illustrated below: 1. Load (preset) to binary 13 2. Count up to 14, 15 (maximum), 0, 1, and 2 3. Inhibit 4. Count down to 1, 0 (minimum), 15, 14, and 13 LOAD A Data Inputs B C D CLK U/D ENP and ENT QA Data Outputs QB QC QD RCO 13 14 15 0 1 2 Count Up 2 2 Inhibit 1 0 15 14 13 Count Down Load absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54ALS169B . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C SN74ALS169B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 2−4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 •               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 recommended operating conditions SN54ALS169B SN74ALS169B MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 UNIT VCC VIH Supply voltage VIL IOH Low-level input voltage 0.7 0.8 V High-level output current −0.4 −0.4 mA IOL fclock Low-level output current 4 8 mA 40 MHz tw Pulse duration, CLK high or low High-level input voltage 2 Clock frequency 2 0 tsu Setup time before CLK↑ th TA Hold time, data after CLK↑ 22 12.5 A, B, C, or D 20 15 ENP or ENT 25 15 LOAD 20 15 U/D 28 15 0 Operating free-air temperature V 0 14 ns ns 0 −55 125 V ns 0 70 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER SN54ALS169B MIN TYP† MAX TEST CONDITIONS VIK VOH VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = − 18 mA IOH = − 0.4 mA VOL VCC = 4.5 V IOL = 4 mA IOL = 8 mA II IIH VCC = 5.5 V, VCC = 5.5 V, VI = 7 V VI = 2.7 V IIL IO‡ VCC = 5.5 V, VCC = 5.5 V, VI = 0.4 V VO = 2.25 V SN74ALS169B MIN TYP† MAX −1.5 VCC − 2 −1.5 VCC − 2 0.25 −20 0.4 UNIT V V 0.25 0.4 0.35 0.5 V 0.1 0.1 20 20 µA −0.2 −0.2 mA −112 mA −112 −30 mA ICC VCC = 5.5 V 15 25 15 25 mA † All typical values are at VCC = 5 V, TA = 25°C. ‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 2−5               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 switching characteristics (see Figure 1) PARAMETER FROM (INPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 Ω, TA = MIN to MAX† TO (OUTPUT) SN54ALS169B MIN fmax tPLH tPHL tPLH tPHL tPLH tPHL tPLH SN74ALS169B MAX MIN 22 CLK RCO CLK Any Q ENT RCO U/D RCO UNIT MAX 40 MHz 3 20 3 20 6 25 6 20 2 20 2 15 5 23 5 20 2 16 2 13 3 24 3 16 4 22 5 19 5 19 tPHL 5 26 † For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. ns ns ns ns absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54AS169A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C SN74AS169A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions SN54AS169A SN74AS169A MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 UNIT VCC VIH Supply voltage VIL IOH Low-level input voltage 0.8 0.8 V High-level output current −2 −2 mA IOL fclock* Low-level output current tw* Pulse duration, CLK high or low High-level input voltage 2 20 Clock frequency tsu* Setup time before CLK↑ th* TA Hold time, data after CLK↑ 2 0 60 0 7.7 6.7 A, B, C, or D 10 8 ENP or ENT 10 8 LOAD 10 8 U/D 14 11 2 0 Operating free-air temperature −55 125 0 * On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested. 2−6 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • V V 20 mA 75 MHz ns ns ns 70 °C               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER SN54AS169A TYP† MAX TEST CONDITIONS MIN VIK VOH VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = − 18 mA IOH = − 2 mA VOL VCC = 4.5 V, IOL = 20 mA VCC = 5.5 V, VI = 7 V VCC = 5.5 V, VI = 2.7 V VCC = 5.5 V, VI = 0.4 V −1.2 VCC − 2 All others 0.25 LOAD, ENT, U/D IIH All others LOAD, ENT, U/D IIL All others −1.2 VCC − 2 LOAD, ENT, U/D II SN74AS169A TYP† MAX MIN 0.5 UNIT V V 0.25 0.5 0.2 0.2 0.1 0.1 40 40 20 20 −1 −1 −0.5 −0.5 V mA µA A mA IO‡ VCC = 5.5 V, VO = 2.25 V −30 −112 −30 −112 mA ICC VCC = 5.5 V 41 63 41 63 mA † All typical values are at VCC = 5 V, TA = 25°C. ‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. switching characteristics (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 Ω, TA = MIN to MAX§ SN54AS169A MIN fmax* tPLH tPHL tPLH tPHL tPLH tPHL tPLH MAX 60 CLK RCO (LOAD high or low) CLK Any Q ENT RCO UNIT SN74AS169A MIN MAX 75 MHz 3 17.5 3 16.5 2 14 2 13 1 7.5 1 7 2 14 2 13 1.5 10 1.5 9 1.5 10 1.5 9 2 14 2 12 U/D RCO tPHL 2 14.5 2 13 * On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested. § For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • ns ns ns ns 2−7               SDAS125B − MARCH 1984 − REVISED DECEMBER 1994 PARAMETER MEASUREMENT INFORMATION SERIES 54ALS/74ALS AND 54AS/74AS DEVICES 7V RL = R1 = R2 VCC S1 RL R1 Test Point From Output Under Test CL (see Note A) From Output Under Test RL Test Point CL (see Note A) CL (see Note A) LOAD CIRCUIT FOR BI-STATE TOTEM-POLE OUTPUTS LOAD CIRCUIT FOR OPEN-COLLECTOR OUTPUTS 3.5 V Timing Input Test Point From Output Under Test LOAD CIRCUIT FOR 3-STATE OUTPUTS 3.5 V High-Level Pulse 1.3 V R2 1.3 V 1.3 V 0.3 V 0.3 V tsu Data Input tw th 3.5 V 1.3 V 3.5 V Low-Level Pulse 1.3 V 0.3 V 1.3 V 0.3 V VOLTAGE WAVEFORMS PULSE DURATIONS VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 3.5 V Output Control (low-level enabling) 1.3 V 1.3 V 0.3 V tPZL Waveform 1 S1 Closed (see Note B) tPLZ 3.5 V Input tPZH 1.3 V 0.3 V tPHL tPLH VOH In-Phase Output VOL 0.3 V 1.3 V 1.3 V VOL tPLH tPHL VOH 1.3 V 1.3 V [3.5 V 1.3 V tPHZ Waveform 2 S1 Open (see Note B) 1.3 V VOH Out-of-Phase Output (see Note C) 0.3 V [0 V 1.3 V 1.3 V VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. When measuring propagation delay items of 3-state outputs, switch S1 is open. D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%. E. The outputs are measured one at a time with one transition per measurement. Figure 1. Load Circuits and Voltage Waveforms 2−8 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • PACKAGE OPTION ADDENDUM www.ti.com 20-Aug-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) Samples (4/5) (6) 8302501EA ACTIVE CDIP J 16 1 Non-RoHS & Green SNPB N / A for Pkg Type -55 to 125 8302501EA SNJ54ALS169BJ Samples JM38510/38003BEA ACTIVE CDIP J 16 1 Non-RoHS & Green SNPB N / A for Pkg Type -55 to 125 JM38510/ 38003BEA Samples M38510/38003BEA ACTIVE CDIP J 16 1 Non-RoHS & Green SNPB N / A for Pkg Type -55 to 125 JM38510/ 38003BEA Samples SN54ALS169BJ ACTIVE CDIP J 16 1 Non-RoHS & Green SNPB N / A for Pkg Type -55 to 125 SN54ALS169BJ Samples SN74ALS169BD ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 ALS169B Samples SN74ALS169BDR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 ALS169B Samples SN74ALS169BN ACTIVE PDIP N 16 25 RoHS & Green NIPDAU N / A for Pkg Type 0 to 70 SN74ALS169BN Samples SN74ALS169BNSR ACTIVE SO NS 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 ALS169B Samples SN74AS169AN ACTIVE PDIP N 16 25 RoHS & Green NIPDAU N / A for Pkg Type 0 to 70 SN74AS169AN Samples SNJ54ALS169BJ ACTIVE CDIP J 16 1 Non-RoHS & Green SNPB N / A for Pkg Type -55 to 125 8302501EA SNJ54ALS169BJ Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
SN74AS169ADRE4 价格&库存

很抱歉,暂时无法提供与“SN74AS169ADRE4”相匹配的价格&库存,您可以联系我们找货

免费人工找货