SN74AS194DR

SN74AS194DR

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    SOIC-16

  • 描述:

    SN74AS194DR

  • 数据手册
  • 价格&库存
SN74AS194DR 数据手册
                SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 • • • • • • SN54AS194 . . . J PACKAGE SN74AS194 . . . D OR N PACKAGE (TOP VIEW) Parallel-to-Serial, Serial-to-Parallel Conversions Left or Right Shifts Parallel Synchronous Loading Direct Overriding Clear Temporary Data-Latching Capability Package Options Include Plastic Small-Outline Packages (D), Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs CLR SR SER A B C D SL SER GND 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC QA QB QC QD CLK S1 S0 description SN54AS194 . . . FK PACKAGE (TOP VIEW) Inhibit clock (temporary data latch/do nothing) Shift right (in the direction QA toward QD) Shift left (in the direction QD toward QA) A B NC C D Parallel (broadside) load 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 QB QC NC QD CLK SL SER GND NC S0 S1 • • • • SR SER CLR NC VCC QA These 4-bit bidirectional universal shift registers feature parallel outputs, right-shift and left-shift serial (SR SER, SL SER) inputs, operatingmode-control (S0, S1) inputs, and a direct overriding clear (CLR) line. The registers have four distinct modes of operation: Parallel synchronous loading is accomplished by applying the four bits of data and taking both S0 and S1 high. The data is loaded into the associated flip-flops and appears at the outputs after the positive transition of the clock (CLK) input. During loading, serial data flow is inhibited. NC − No internal connection Shift right is accomplished synchronously with the rising edge of the clock pulse when S0 is high and S1 is low. Serial data for this mode is entered at the shift-right data input. When S0 is low and S1 is high, data shifts left synchronously and new data is entered at the shift-left serial inputs. Clocking of the flip-flop is inhibited when both mode-control inputs are low. The SN54AS194 is characterized for operation over the full military temperature range of −55°C to 125°C. The SN74AS194 is characterized for operation from 0°C to 70°C. Copyright  1994, Texas Instruments Incorporated    !"#$ % &'!!($ #%  )'*+&#$ ,#$(!,'&$% &!" $ %)(&&#$% )(! $.( $(!"%  (/#% %$!'"($% %$#,#!, 0#!!#$1- !,'&$ )!&(%%2 ,(% $ (&(%%#!+1 &+',( $(%$2  #++ )#!#"($(!%- • DALLAS, TEXAS 75265 • HOUSTON, TEXAS 77251−1443 POST OFFICE BOX 655303 POST OFFICE BOX 1443 1                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 FUNCTION TABLE INPUTS MODE CLR OUTPUTS SERIAL S1 S0 CLK PARALLEL LEFT RIGHT A B C D QA QB QC QD L X X X X X X X X X L L L L H X X L X X X X X X QA0 QB0 QC0 QD0 H H H ↑ X X a b c d a b c d H L H ↑ X H X X X X H QAn QBn QCn H L H ↑ X L X X X X L H L ↑ H X X X X X QBn QAn QCn QBn QDn QCn H H H L ↑ L X X X X X QBn QCn QDn L H H L L X X X X X X X QA0 QB0 QC0 QD0 H = high level (steady state); L = low level (steady state); X = irrelevant (any input, including transitions); ↑ = transition from low to high level; a, b, c, d = the level of steady-state input at inputs A, B, C, or D, respectively; QA0, QB0, QC0, QD0 = the level of QA, QB, QC, or QD, respectively, before the indicated steady-state input conditions were established; QAn, QBn, QCn, QDn = the level of QA, QB, QC, respectively, before the most recent ↑ transition of the clock. logic symbol† CLR S0 S1 CLK 1 9 10 11 SRG4 R 0 M 1 C4 1 SR SER A B C D SL SER 2 3 4 5 6 7 0 3 /2 15 1, 4D QA 3, 4D 14 3, 4D 13 3, 4D QC 3, 4D 12 QD 2, 4D † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. 2 QB • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 •                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 logic diagram (positive logic) Parallel Inputs A S1 S0 SR SER 10 D 6 3 9 2 7 Two Identical Channels Not Shown† 1S CLK CLR SL SER 1S C1 1R C1 1R R R 11 1 15 12 QA QD Parallel Outputs † I/O ports not shown: QB (14) and QC (13) Pin numbers shown are for the D, J, and N packages. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 3                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 CLK ModeControl Inputs S0 S1 CLR Serial Data Inputs Parallel Data Inputs R L A H B L C H D L QA QB Outputs QC QD Shift Right Shift Left Inhibit Clear Clear Load Figure 1. Typical Clear, Load, Right-Shift, and Clear Sequences absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54AS194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C SN74AS194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 •                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 recommended operating conditions SN54AS194 SN74AS194 MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 UNIT VCC VIH Supply voltage VIL IOH Low-level input voltage 0.8 0.8 V High-level output current −2 −2 mA IOL fclock* Low-level output current 20 20 mA 80 MHz tw* tsu* High-level input voltage 2 Clock frequency 0 4.5 CLK high 4 4 CLK low 6 7 Select 9 9.5 3.5 4 6 6 Hold time, data after CLK↑ 0.5 0.5 Operating free-air temperature −55 Data Setup time before CLK↑ 125 V 0 4 Clear inactive state th* TA 75 CLR Pulse duration V 2 ns ns ns 0 °C 70 * On products compliant to MIL-STD-883, Class B, these parameters are based on characterization data, but are not production tested. electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH VOL SN54AS194 MIN TYP† MAX TEST CONDITIONS VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = − 18 mA IOH = − 2 mA VCC = 4.5 V, IOL = 20 mA −1.2 VCC −2 VCC = 5.5 V, VI = 7 V VCC = 5.5 V, VI = 2.7 V VCC = 5.5 V, VI = 0.4 V IO‡ VCC = 5.5 V, ICC VCC = 5.5 V VO = 2.25 V Outputs high Mode, SL, SR 0.35 Data, CLK, CLR IIH Mode, SL, SR Data, CLK, CLR IIL Mode, SL, SR Outputs low −1.2 VCC −2 Data, CLK, CLR II SN74AS194 MIN TYP† MAX −30 0.5 V V 0.35 0.5 0.1 0.1 0.2 0.2 20 20 40 40 −0.5 −0.5 −1 −1 −112 UNIT −30 −112 30 49 30 43 38 60 38 53 V mA µA A mA mA mA † All typical values are at VCC = 5 V, TA = 25°C. ‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 5                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 Ω, TA = MIN to MAX† SN54AS194 MIN fmax* tPLH tPHL tPHL MAX 75 CLK Any Q CLR Any Q UNIT SN74AS194 MIN MAX 80 MHz 2.5 8 3 7 2.5 8 3 7 3.5 13 4 12 * On products compliant to MIL-STD-883, Class B, these parameters are based on characterization data, but are not production tested. † For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. 6 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • ns ns                 SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994 PARAMETER MEASUREMENT INFORMATION SERIES 54ALS/74ALS AND 54AS/74AS DEVICES 7V RL = R1 = R2 VCC S1 RL R1 Test Point From Output Under Test CL (see Note A) From Output Under Test RL Test Point CL (see Note A) CL (see Note A) LOAD CIRCUIT FOR BI-STATE TOTEM-POLE OUTPUTS 3.5 V High-Level Pulse 1.3 V R2 LOAD CIRCUIT FOR 3-STATE OUTPUTS LOAD CIRCUIT FOR OPEN-COLLECTOR OUTPUTS 3.5 V Timing Input Test Point From Output Under Test 1.3 V 1.3 V 0.3 V 0.3 V tsu Data Input tw th 3.5 V 1.3 V 3.5 V Low-Level Pulse 1.3 V 0.3 V 1.3 V 0.3 V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VOLTAGE WAVEFORMS PULSE DURATIONS 3.5 V Output Control (low-level enabling) 1.3 V 1.3 V 0.3 V tPZL Waveform 1 S1 Closed (see Note B) tPLZ 3.5 V Input tPHZ 1.3 V 0.3 V tPHL tPLH VOH In-Phase Output VOL 0.3 V 1.3 V 1.3 V VOL tPLH tPHL VOH 1.3 V 1.3 V [3.5 V 1.3 V tPZH Waveform 2 S1 Open (see Note B) 1.3 V VOH Out-of-Phase Output (see Note C) 0.3 V [0 V 1.3 V 1.3 V VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. When measuring propagation delay items of 3-state outputs, switch S1 is open. D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%. E. The outputs are measured one at a time with one transition per measurement. Figure 2. Load Circuits and Voltage Waveforms • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 7 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) SN74AS194D ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 AS194 SN74AS194DR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 AS194 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
SN74AS194DR 价格&库存

很抱歉,暂时无法提供与“SN74AS194DR”相匹配的价格&库存,您可以联系我们找货

免费人工找货