SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
•
•
•
•
•
•
SN54AS194 . . . J PACKAGE
SN74AS194 . . . D OR N PACKAGE
(TOP VIEW)
Parallel-to-Serial, Serial-to-Parallel
Conversions
Left or Right Shifts
Parallel Synchronous Loading
Direct Overriding Clear
Temporary Data-Latching Capability
Package Options Include Plastic
Small-Outline Packages (D), Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
CLR
SR SER
A
B
C
D
SL SER
GND
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
QA
QB
QC
QD
CLK
S1
S0
description
SN54AS194 . . . FK PACKAGE
(TOP VIEW)
Inhibit clock (temporary data latch/do nothing)
Shift right (in the direction QA toward QD)
Shift left (in the direction QD toward QA)
A
B
NC
C
D
Parallel (broadside) load
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
QB
QC
NC
QD
CLK
SL SER
GND
NC
S0
S1
•
•
•
•
SR SER
CLR
NC
VCC
QA
These 4-bit bidirectional universal shift registers
feature parallel outputs, right-shift and left-shift
serial (SR SER, SL SER) inputs, operatingmode-control (S0, S1) inputs, and a direct
overriding clear (CLR) line. The registers have
four distinct modes of operation:
Parallel synchronous loading is accomplished by
applying the four bits of data and taking both S0
and S1 high. The data is loaded into the
associated flip-flops and appears at the outputs
after the positive transition of the clock (CLK)
input. During loading, serial data flow is inhibited.
NC − No internal connection
Shift right is accomplished synchronously with the rising edge of the clock pulse when S0 is high and S1 is low.
Serial data for this mode is entered at the shift-right data input. When S0 is low and S1 is high, data shifts left
synchronously and new data is entered at the shift-left serial inputs. Clocking of the flip-flop is inhibited when
both mode-control inputs are low.
The SN54AS194 is characterized for operation over the full military temperature range of −55°C to 125°C. The
SN74AS194 is characterized for operation from 0°C to 70°C.
Copyright 1994, Texas Instruments Incorporated
!"#$ % &'!!($ #% )'*+$ ,#$(!,'&$% &!" $ %)(&$% )(! $.( $(!"% (/#%
%$!'"($%
%$#,#!, 0#!!#$1- !,'&$ )!&(%%2 ,(% $ (&(%%#!+1 &+',(
$(%$2 #++ )#!#"($(!%-
• DALLAS, TEXAS 75265
• HOUSTON, TEXAS 77251−1443
POST OFFICE BOX 655303
POST OFFICE BOX 1443
1
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
FUNCTION TABLE
INPUTS
MODE
CLR
OUTPUTS
SERIAL
S1
S0
CLK
PARALLEL
LEFT
RIGHT
A
B
C
D
QA
QB
QC
QD
L
X
X
X
X
X
X
X
X
X
L
L
L
L
H
X
X
L
X
X
X
X
X
X
QA0
QB0
QC0
QD0
H
H
H
↑
X
X
a
b
c
d
a
b
c
d
H
L
H
↑
X
H
X
X
X
X
H
QAn
QBn
QCn
H
L
H
↑
X
L
X
X
X
X
L
H
L
↑
H
X
X
X
X
X
QBn
QAn
QCn
QBn
QDn
QCn
H
H
H
L
↑
L
X
X
X
X
X
QBn
QCn
QDn
L
H
H
L
L
X
X
X
X
X
X
X
QA0
QB0
QC0
QD0
H = high level (steady state); L = low level (steady state); X = irrelevant (any input, including transitions); ↑ = transition from
low to high level; a, b, c, d = the level of steady-state input at inputs A, B, C, or D, respectively; QA0, QB0, QC0, QD0 = the
level of QA, QB, QC, or QD, respectively, before the indicated steady-state input conditions were established; QAn, QBn, QCn,
QDn = the level of QA, QB, QC, respectively, before the most recent ↑ transition of the clock.
logic symbol†
CLR
S0
S1
CLK
1
9
10
11
SRG4
R
0
M
1
C4
1
SR SER
A
B
C
D
SL SER
2
3
4
5
6
7
0
3
/2
15
1, 4D
QA
3, 4D
14
3, 4D
13
3, 4D
QC
3, 4D
12
QD
2, 4D
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2
QB
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
logic diagram (positive logic)
Parallel Inputs
A
S1
S0
SR SER
10
D
6
3
9
2
7
Two
Identical
Channels
Not
Shown†
1S
CLK
CLR
SL SER
1S
C1
1R
C1
1R
R
R
11
1
15
12
QA
QD
Parallel Outputs
† I/O ports not shown: QB (14) and QC (13)
Pin numbers shown are for the D, J, and N packages.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
3
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
CLK
ModeControl
Inputs
S0
S1
CLR
Serial
Data
Inputs
Parallel
Data
Inputs
R
L
A
H
B
L
C
H
D
L
QA
QB
Outputs
QC
QD
Shift Right
Shift Left
Inhibit
Clear
Clear Load
Figure 1. Typical Clear, Load, Right-Shift, and Clear Sequences
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54AS194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74AS194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
4
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
recommended operating conditions
SN54AS194
SN74AS194
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.8
0.8
V
High-level output current
−2
−2
mA
IOL
fclock*
Low-level output current
20
20
mA
80
MHz
tw*
tsu*
High-level input voltage
2
Clock frequency
0
4.5
CLK high
4
4
CLK low
6
7
Select
9
9.5
3.5
4
6
6
Hold time, data after CLK↑
0.5
0.5
Operating free-air temperature
−55
Data
Setup time before CLK↑
125
V
0
4
Clear inactive state
th*
TA
75
CLR
Pulse duration
V
2
ns
ns
ns
0
°C
70
* On products compliant to MIL-STD-883, Class B, these parameters are based on characterization data, but are not production tested.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
SN54AS194
MIN TYP†
MAX
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = − 18 mA
IOH = − 2 mA
VCC = 4.5 V,
IOL = 20 mA
−1.2
VCC −2
VCC = 5.5 V,
VI = 7 V
VCC = 5.5 V,
VI = 2.7 V
VCC = 5.5 V,
VI = 0.4 V
IO‡
VCC = 5.5 V,
ICC
VCC = 5.5 V
VO = 2.25 V
Outputs high
Mode, SL, SR
0.35
Data, CLK, CLR
IIH
Mode, SL, SR
Data, CLK, CLR
IIL
Mode, SL, SR
Outputs low
−1.2
VCC −2
Data, CLK, CLR
II
SN74AS194
MIN TYP†
MAX
−30
0.5
V
V
0.35
0.5
0.1
0.1
0.2
0.2
20
20
40
40
−0.5
−0.5
−1
−1
−112
UNIT
−30
−112
30
49
30
43
38
60
38
53
V
mA
µA
A
mA
mA
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
5
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
SN54AS194
MIN
fmax*
tPLH
tPHL
tPHL
MAX
75
CLK
Any Q
CLR
Any Q
UNIT
SN74AS194
MIN
MAX
80
MHz
2.5
8
3
7
2.5
8
3
7
3.5
13
4
12
* On products compliant to MIL-STD-883, Class B, these parameters are based on characterization data, but are not production tested.
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
6
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
ns
ns
SDAS212A − DECEMBER 1983 − REVISED DECEMBER 1994
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
From Output
Under Test
1.3 V
1.3 V
0.3 V
0.3 V
tsu
Data
Input
tw
th
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
3.5 V
Input
tPHZ
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
VOL
0.3 V
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
1.3 V
1.3 V
[3.5 V
1.3 V
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOH
Out-of-Phase
Output
(see Note C)
0.3 V
[0 V
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 2. Load Circuits and Voltage Waveforms
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
7
PACKAGE OPTION ADDENDUM
www.ti.com
10-Dec-2020
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
SN74AS194D
ACTIVE
SOIC
D
16
40
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
AS194
SN74AS194DR
ACTIVE
SOIC
D
16
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
AS194
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of