SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
•
•
•
•
•
D OR N PACKAGE
(TOP VIEW)
Fully Synchronous Operation for Counting
and Programming
Internal Look-Ahead Circuitry for Fast
Counting
Carry Output for N-Bit Cascading
Fully Independent Clock Circuit
Package Options Include Plastic
Small-Outline Packages and Standard
Plastic 300-mil DIPs
U/D
CLK
A
B
C
D
ENP
GND
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
RCO
QA
QB
QC
QD
ENT
LOAD
description
This synchronous, presettable, 4-bit up/down binary counter features an internal carry look-ahead circuitry for
cascading in high-speed counting applications. Synchronous operation is provided by having all flip-flops
clocked simultaneously so that the outputs change coincident with each other when so instructed by the
count-enable (ENP, ENT) inputs and internal gating. This mode of operation eliminates the output counting
spikes that are normally associated with asynchronous (ripple-clock) counters. A buffered clock (CLK) input
triggers the four flip-flops on the rising (positive-going) edge of the clock waveform.
This counter is fully programmable; that is, it may be preset to any number between 0 and its maximum count.
The load-input circuitry allows loading with the carry-enable output of cascaded counters. As loading is
synchronous, setting up a low level at the load (LOAD) input disables the counter and causes the outputs to
agree with the data inputs after the next clock pulse.
The carry look-ahead circuitry provides for cascading counters for n-bit synchronous application without
additional gating. Instrumental in accomplishing this function are two count-enable (ENP, ENT) inputs and a
ripple-carry (RCO) output. Both ENP and ENT must be low to count. The direction of the count is determined
by the level of the up/down (U/D) input. When U/D is high, the counter counts up; when low, it counts down. Input
ENT is fed forward to enable the RCO. RCO thus enabled will produce a low-level pulse while the count is zero
(all inputs low) counting down or maximum (9 or 15) counting up. This low-level overflow ripple-carry pulse can
be used to enable successive cascaded stages. Transitions at ENP or ENT are allowed regardless of the level
of the clock input. All inputs are diode clamped to minimize transmission-line effects, thereby simplifying system
design.
The SN74F169 features a fully independent clock circuit. Changes at control inputs (ENP, ENT, LOAD or U/D)
that will modify the operating mode have no effect on the contents of the counter until clocking occurs. The
function of the counter (whether enabled, disabled, loading, or counting) will be dictated solely by the conditions
meeting the setup and hold times.
The SN74F169 is characterized for operation from 0°C to 70°C.
Copyright 1993, Texas Instruments Incorporated
!"# $ %&'# "$ (&)*%"# +"#',
+&%#$ %! # $('%%"#$ (' #-' #'!$ '."$ $#&!'#$
$#"+"+ /""#0, +&%# (%'$$1 +'$ # '%'$$"*0 %*&+'
#'$#1 "** (""!'#'$,
• DALLAS, TEXAS 75265
• HOUSTON, TEXAS 77251−1443
POST OFFICE BOX 655303
POST OFFICE BOX 1443
2−1
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
logic symbol†
9
LOAD
1
U/D
10
ENT
ENP
CLK
7
2
CTRDIV16
M1 [LOAD]
M2 [COUNT]
M3 [UP]
M4 [DOWN]
3,5CT = 15
4,5CT = 0
G5
15
RCO
G6
2,3,5,6+/C7
2,4,5,6 −
A
B
C
D
3
1
1, 7D
4
2
5
4
6
8
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2−2
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
14
13
12
11
QA
QB
QC
QD
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
logic diagram (positive logic)
LOAD
U/D
ENT
ENP
9
1
10
7
15
CLK
A
RCO
2
G2
1, 2T/C3
1, 3D
3
14
QA
M1
B
G2
1, 2T/C3
1, 3D
4
13
QB
M1
C
G2
1, 2T/C3
1, 3D
5
12
QC
M1
D
G2
1, 2T/C3
1, 3D
6
11
QD
M1
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
2−3
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
logic symbol, each flip-flop
TE
G2
Q1
Q2
1, 2T/C3
CLK
DATA
1, 3D
Q1
LOAD
M1
Q2
logic diagram, each flip-flop (positive logic)
TE
(Toggle
Enable)
CLK
Q1
Q2
DATA
LOAD
Q1
Q2
FUNCTION TABLE
(each flip-flop)
COUNTER
INPUTS
2−4
LOAD
CLK
L
L
FLIP-FLOP INPUTS
LOAD
TE
↑
H
↑
H
H
↑
H
↑
OUTPUTS
CLK
DATA
Q
L
↓
H
H
L
L
↓
L
L
H
L
H
↓
X
Q0
Q0
L
L
↓
X
Q0
Q0
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
Q
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
typical load, count, and inhibit sequences
Illustrated below is the following sequence:
1. Load (preset) to binary thirteen
2. Count up to fourteen, fifteen (maximum), zero, one, and two
3. Inhibit
4. Count down to one, zero (minimum), fifteen, fourteen, and thirteen
LOAD
A
Data
Inputs
B
C
D
CLK
U/D
ENP and ENT
QA
Data
Outputs
QB
QC
QD
RCO
13
14
15
0
1
2
Count Up
2
2
Inhibit
1
0
15
14
13
Count Down
Load
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
2−5
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −1.2 V to 7 V
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA to 5 mA
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Current into any output in the low state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
recommended operating conditions
MIN
NOM
MAX
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IIK
Low-level input voltage
0.8
V
Input clamp current
−18
mA
IOH
IOL
High-level output current
−1
mA
Low-level output current
20
mA
TA
Operating free-air temperature
70
°C
High-level input voltage
2
V
V
0
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
II
IIH
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V,
II = − 18 mA
IOH = − 1 mA
VCC = 4.75 V,
VCC = 4.5 V,
IOH = − 1 mA
IOL = 20 mA
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
ENT
IIL
All others
MIN
TYP‡
2.5
3.4
MAX
UNIT
−1.2
V
V
2.7
0.3
0.5
V
0.1
mA
20
µA
− 1.2
VCC = 5.5 V,
VI = 0.5 V
− 0.6
mA
IOS§
VCC = 5.5 V,
VO = 0
−60
−150
mA
ICC
VCC = 5.5 V,
See Note 2
38
52
mA
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTE 2: ICC is measured after applying a momentary 4.5 V, then ground, to the clock input with B and ENT inputs high and all other inputs low.
2−6
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
VCC = 5 V,
TA = 25°C
fclock
tw
tsu
Clock frequency
Pulse duration
CLK high or low
Setup time
Hold time
MAX
0
100
MIN
MAX
UNIT
0
90
MHz
5
5.5
Data before CLK↑
High or low
4
4.5
LOAD before CLK↑
High or low
8
9
ENP and ENT before CLK↑
High or low
5
6
High
11
12.5
U/D before CLK↑
th
MIN
Low
7
8
Data after CLK↑
High or low
3
3.5
LOAD after CLK↑
High or low
0
0
ENP and ENT after CLK↑
High or low
0
0
U/D after CLK↑
High or low
0
0
ns
ns
ns
switching characteristics (see Note 3)
PARAMETER
fmax
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
FROM
(INPUT)
TO
(OUTPUT)
CLK
Q
CLK
RCO
ENT
RCO
U/D
RCO
VCC = 5 V,
CL = 50 pF,
RL = 500 Ω,
TA = 25°C
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
MIN
TYP
100
115
MAX
MIN
2.2
6.1
8.5
2.2
9.5
3.2
8.6
11.5
3.2
13
4.7
11.6
15.5
4.7
17
3.2
8.1
11
3.2
12.5
1.7
4.1
6
1.7
7
1.7
5.6
8
1.7
9
2.7
8.1
11
2.7
12.5
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
MAX
90
tPHL
3.2
7.6
10.5
3.2
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
NOTE 3: Load circuits and waveforms are shown in Section 1.
UNIT
MHz
12
ns
ns
ns
ns
2−7
SDFS089 − MARCH 1987 − REVISED OCTOBER 1993
2−8
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
PACKAGE OPTION ADDENDUM
www.ti.com
6-Sep-2015
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
SN74F169D
OBSOLETE
SOIC
D
16
TBD
Call TI
Call TI
0 to 70
F169
SN74F169N
OBSOLETE
PDIP
N
16
TBD
Call TI
Call TI
0 to 70
SN74F169N
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
6-Sep-2015
Addendum-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2016, Texas Instruments Incorporated