SCLS079E − MARCH 1984 − REVISED MARCH 2004
D Wide Operating Voltage Range of 2 V to 6 V
D Outputs Can Drive Up To 10 LSTTL Loads
D Low Power Consumption, 20-µA Max ICC
D
D
D
D
Typical tpd = 7 ns
±4-mA Output Drive at 5 V
Low Input Current of 1 µA Max
Unbuffered Outputs
SN54HCU04 . . . J OR W PACKAGE
SN74HCU04 . . . D, DB, N, NS, OR PW PACKAGE
(TOP VIEW)
1
14
2
13
3
12
4
11
5
10
6
9
7
8
1Y
1A
NC
VCC
6A
VCC
6A
6Y
5A
5Y
4A
4Y
2A
NC
2Y
NC
3A
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
6Y
NC
5A
NC
5Y
3Y
GND
NC
4Y
4A
1A
1Y
2A
2Y
3A
3Y
GND
SN54HCU04 . . . FK PACKAGE
(TOP VIEW)
NC − No internal connection
description/ordering information
The ’HCU04 devices contain six independent inverters. They perform the Boolean function Y = A in positive
logic.
ORDERING INFORMATION
PACKAGE†
TA
PDIP − N
SN74HCU04N
Tube of 50
SN74HCU04D
Reel of 2500
SN74HCU04DR
Reel of 250
SN74HCU04DT
SOP − NS
Reel of 2000
SN74HCU04NSR
HCU04
SSOP − DB
Reel of 2000
SN74HCU04DBR
HU04
Reel of 90
SN74HCU04PW
Reel of 2000
SN74HCU04PWR
Reel of 250
SN74HCU04PWT
CDIP − J
Tube of 25
SNJ54HCU04J
SNJ54HCU04J
CFP − W
Tube of 150
SNJ54HCU04W
SNJ54HCU04W
LCCC − FK
Tube of 55
SNJ54HCU04FK
TSSOP − PW
−55°C
−55
C to 125
125°C
C
TOP-SIDE
MARKING
Tube of 25
SOIC − D
−40°C
−40
C to 85
85°C
C
ORDERABLE
PART NUMBER
SN74HCU04N
HCU04
HCU04
SNJ54HCU04FK
† Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are
available at www.ti.com/sc/package.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2004, Texas Instruments Incorporated
! "#$ %!&
% "! "! '! ! !(
!
%% )*& % "!+ %! !!$* $%!
!+ $$ "!!&
"% "$ ,
-./.010 $$ "!! ! !!%
$! '!)! !%& $$ '! "% "%
"!+ %! !!$* $%! !+ $$ "!!&
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SCLS079E − MARCH 1984 − REVISED MARCH 2004
FUNCTION TABLE
(each inverter)
INPUT
A
OUTPUT
Y
H
L
L
H
logic diagram (positive logic)
A
Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Package thermal impedance, θJA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
SN54HCU04
VCC
VIH
VIL
VI
VO
Supply voltage
High-level input voltage
Low-level input voltage
SN74HCU04
MIN
NOM
MAX
2
5
6
MIN
NOM
MAX
2
5
6
VCC = 2 V
VCC = 4.5 V
1.7
1.7
3.6
3.6
VCC = 6 V
VCC = 2 V
4.8
4.8
VCC = 4.5 V
VCC = 6 V
Input voltage
0
Output voltage
0
0.5
0.5
1.35
1.8
1.8
0
0
V
V
1.35
VCC
VCC
UNIT
VCC
VCC
V
V
V
TA
Operating free-air temperature
−55
125
−40
85
°C
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SCLS079E − MARCH 1984 − REVISED MARCH 2004
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
IOH = −20 µA
VOH
VI = VCC or GND
IOH = −4 mA
IOH = −5.2 mA
IOL = 20 µA
VOL
VI = VCC or GND
IOL = 4 mA
IOL = 5.2 mA
II
ICC
VI = VCC or 0
VI = VCC or 0,
IO = 0
TA = 25°C
TYP
MAX
SN74HCU04
MIN
2V
1.8
1.8
4
4
4
6V
5.5
5.5
5.5
4.5 V
3.98
3.7
3.84
6V
5.48
4.5 V
MIN
MAX
MIN
MAX
UNIT
1.8
5.2
V
5.34
2V
0.2
0.2
0.2
4.5 V
0.5
0.5
0.5
6V
0.5
0.5
0.5
4.5 V
0.26
0.4
0.33
6V
0.26
0.4
0.33
6V
±100
±1000
±1000
nA
2
40
20
µA
10
10
10
pF
6V
Ci
SN54HCU04
VCC
2 V to 6 V
3
V
switching characteristics over recommended operating free-air temperature range, CL = 50 pF
(unless otherwise noted) (see Figure 1)
TA = 25°C
TYP
MAX
SN54HCU04
SN74HCU04
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC
2V
40
80
120
100
tpd
A
Y
4.5 V
8
16
24
20
6V
7
14
20
17
tf
Y
MIN
MIN
MAX
MIN
MAX
2V
38
75
110
95
4.5 V
8
15
22
19
6V
6
13
19
16
UNIT
ns
ns
operating characteristics, TA = 25°C
PARAMETER
Cpd
TEST CONDITIONS
Power dissipation capacitance per inverter
POST OFFICE BOX 655303
No load
• DALLAS, TEXAS 75265
TYP
20
UNIT
pF
3
SCLS079E − MARCH 1984 − REVISED MARCH 2004
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
Test
Point
Input
50%
VCC
50%
0V
CL = 50 pF
(see Note A)
tPLH
In-Phase
Output
LOAD CIRCUIT
tPHL
90%
50%
10%
90%
tr †
tPHL
Input
50%
10%
90%
90%
tr
VCC
50%
10% 0 V
tf
Out-of-Phase
Output
90%
VOH
50%
10%
VOL
tf
tPLH
50%
10%
tf
50%
10%
90%
VOH
VOL
tr †
† tr is not applicable to ’HCU devices.
VOLTAGE WAVEFORM
INPUT RISE AND FALL TIMES
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
NOTES: A. CL includes probe and test-fixture capacitance.
B. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following
characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 6 ns, tf = 6 ns.
C. The outputs are measured one at a time, with one input transition per measurement.
D. tPLH and tPHL are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
2-Dec-2023
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
Samples
(4/5)
(6)
86010012A
ACTIVE
LCCC
FK
20
55
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
86010012A
SNJ54HCU
04FK
8601001CA
ACTIVE
CDIP
J
14
25
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
8601001CA
SNJ54HCU04J
Samples
SN54HCU04J
ACTIVE
CDIP
J
14
25
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
SN54HCU04J
Samples
Samples
SN74HCU04D
LIFEBUY
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
SN74HCU04DR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU | SN
Level-1-260C-UNLIM
-40 to 85
HCU04
SN74HCU04DT
LIFEBUY
SOIC
D
14
250
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
SN74HCU04N
ACTIVE
PDIP
N
14
25
RoHS & Green
NIPDAU
N / A for Pkg Type
-40 to 85
SN74HCU04N
Samples
SN74HCU04NE4
ACTIVE
PDIP
N
14
25
RoHS & Green
NIPDAU
N / A for Pkg Type
-40 to 85
SN74HCU04N
Samples
SN74HCU04NSR
ACTIVE
SO
NS
14
2000
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
Samples
Samples
SN74HCU04PW
LIFEBUY
TSSOP
PW
14
90
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
SN74HCU04PWR
ACTIVE
TSSOP
PW
14
2000
RoHS & Green
NIPDAU | SN
Level-1-260C-UNLIM
-40 to 85
HCU04
Samples
SN74HCU04PWRG4
ACTIVE
TSSOP
PW
14
2000
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
Samples
SN74HCU04PWT
LIFEBUY
TSSOP
PW
14
250
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
HCU04
SNJ54HCU04FK
ACTIVE
LCCC
FK
20
55
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
86010012A
SNJ54HCU
04FK
SNJ54HCU04J
ACTIVE
CDIP
J
14
25
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
8601001CA
SNJ54HCU04J
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
Addendum-Page 1
Samples
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
2-Dec-2023
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
很抱歉,暂时无法提供与“SNJ54HCU04J”相匹配的价格&库存,您可以联系我们找货
免费人工找货