SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
D B Grade Is 100% Tested for Noise
D
D
D
30 nV/√Hz Max at f = 10 Hz
12 nV/√Hz Max at f = 1 kHz
Low Input Offset Voltage . . . 500 µV Max
Excellent Offset Voltage Stability
With Temperature . . . 0.5 µV/°C Typ
Rail-to-Rail Output Swing
D Low Input Bias Current
D
D
1 pA Typ at TA = 25°C
Common-Mode Input Voltage Range
Includes the Negative Rail
Fully Specified For Both Single-Supply and
Split-Supply Operation
TYPICAL EQUIVALENT
INPUT NOISE VOLTAGE
vs
FREQUENCY
description
The combination of excellent DC and noise
performance with a common-mode input voltage
range that includes the negative rail makes these
devices an ideal choice for high-impedance,
low-level signal-conditioning applications in either
single-supply or split-supply configurations.
60
V n − Equivalent Input Noise Voltage − nV/ Hz
Hz
Vn
The TLC220x, TLC220xA, TLC220xB, and
TLC220xY are precision, low-noise operational
amplifiers using Texas Instruments Advanced
LinCMOS process. These devices combine the
noise performance of the lowest-noise JFET
amplifiers with the dc precision available
previously only in bipolar amplifiers. The
Advanced LinCMOS process uses silicon-gate
technology to obtain input offset voltage stability
with temperature and time that far exceeds that
obtainable using metal-gate technology. In
addition, this technology makes possible input
impedance levels that meet or exceed levels
offered by top-gate JFET and expensive
dielectric-isolated devices.
VDD = 5 V
RS = 20 Ω
TA = 25°C
50
40
30
20
10
0
1
10
100
1k
10 k
f − Frequency − Hz
The device inputs and outputs are designed to withstand −100-mA surge currents without sustaining latch-up.
In addition, internal ESD-protection circuits prevent functional failures at voltages up to 2000 V as tested under
MIL-PRF-38535, Method 3015.2; however, care should be exercised in handling these devices as exposure
to ESD may result in degradation of the parametric performance.
The C-suffix devices are characterized for operation from 0°C to 70°C. The I-suffix devices are characterized
for operation from − 40 °C to 85°C. The M-suffix devices are characterized for operation over the full military
temperature range of −55°C to 125°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Advanced LinCMOS is a trademark of Texas Instruments Incorporated. All other trademarks are the property of their respective owners.
Copyright 1997−2008, Texas Instruments Incorporated
/0 / .$
" # !"
# . !1%
"
"+
!"# .$ " #.
"# ") "$# .
# #"!$"#
#"
*
"-+ !" ##, # " ##
%- %!
"#", .
%%
$"#+
!"# $%
" " &'(&(
%%
$"#
"#"
!%## ")*# "+
%% ") !"# !"
##, # " ##
%- %! "#", .
%%
$"#+
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201 AVAILABLE OPTIONS
PACKAGED DEVICES
TA
0°C
0
C to 70
70°C
C
−40°C
−40
C to 85
85°C
C
−55°C
−55
C to 125
125°C
C
VIOmax
AT 25°C
Vnmax
f = 10 Hz
AT 25°C
Vnmax
f = 1 kHz
AT 25°C
200 µV
35 nV/√Hz
15 nV/√Hz
TLC2201ACD
200 µV
30 nV/√Hz
12 nV/√Hz
TLC2201BCD
500 µV
—
—
TLC2201CD
200 µV
35 nV/√Hz
15 nV/√Hz
TLC2201AID
200 µV
30 nV/√Hz
12 nV/√Hz
TLC2201BID
SMALL
OUTLINE†
(D)
CHIP
CARRIER
(FK)
CERAMIC
DIP
(JG)
PLASTIC
DIP
(P)
CHIP
FORM‡
(Y)
TLC2201ACP
—
TLC2201BCP
—
TLC2201Y
TLC2201CP
TLC2201AIP
—
—
TLC2201BIP
500 µV
—
—
TLC2201ID
200 µV
35 nV/√Hz
15 nV/√Hz
TLC2201AMD
TLC2201AMFK
TLC2201AMJG
TLC2201AMP
200 µV
30 nV/√Hz
12 nV/√Hz
TLC2201BMD
TLC2201BMFK
TLC2201BMJG
TLC2201BMP
—
TLC2201IP
500 µV
TLC2201MD
TLC2201MFK
TLC2201MJG
—
—
† The D packages are available taped and reeled. Add R suffix to device type (e.g. TLC220xBCDR).
‡ Chip forms are tested at 25°C only.
—
TLC2201MP
TLC2202 AVAILABLE OPTIONS
PACKAGED DEVICES
TA
0°C
0
C to 70°C
70 C
40°C
85°C
− 40
C to 85
C
− 55
55°C
C to 125
125°C
C
SMALL
OUTLINE†
(D)
PLASTIC
SMALL
OUTLINE
(PS)
CHIP
CARRIER
(FK)
CERAMIC
DIP
(JG)
PLASTIC
DIP
(P)
12 nV/√Hz
TLC2202BCD
—
—
—
TLC2202BCP
15 nV/√Hz
TLC2202ACD
—
—
—
TLC2202ACP
—
—
TLC2202CD
TLC2202CPSR
—
—
TLC2202CP
500 µV
30 nV/√Hz
12 nV/√Hz
TLC2202BID
—
—
—
TLC2202BIP
500 µV
35 nV/√Hz
15 nV/√Hz
TLC2202AID
—
—
—
TLC2202AIP
VIOmax
AT 25°C
Vnmax
f = 10 Hz
AT 25°C
Vnmax
f = 1 kHz
AT 25°C
500 µV
30 nV/√Hz
500 µV
35 nV/√Hz
1 mV
1 mV
—
—
TLC2202ID
—
—
—
TLC2202IP
500 µV
30 nV/√Hz
12 nV/√Hz
TLC2202BMD
—
TLC2202BMFK
TLC2202BMJG
TLC2202BMP
500 µV
35 nV/√Hz
15 nV/√Hz
TLC2202AMD
—
TLC2202AMFK
TLC2202AMJG
TLC2202AMP
1 mV
—
—
TLC2202MD
—
TLC2202MFK
TLC2202MJG
TLC2202MP
† The D packages are available taped and reeled. Add R suffix to device type (e.g. TLC220xBCDR).
‡ Chip forms are tested at 25°C only.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CHIP
FORM‡
(Y)
TLC2202Y
—
—
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201
D, JG, OR P PACKAGE
(TOP VIEW)
NC
IN −
IN +
VDD − /GND
1
8
2
7
3
6
4
5
NC
VDD +
OUT
NC
TLC2202
PS, JG, OR P PACKAGE
(TOP VIEW)
1OUT
1IN −
1IN +
VDD − /GND
1
8
2
7
3
6
4
5
TLC2202
D PACKAGE
(TOP VIEW)
TLC2201
FK PACKAGE
(TOP VIEW)
3 2 1 20 19
18
5
17
6
16
7
8
15
14
9 10 11 12 13
14
2
13
3
12
4
11
5
10
6
9
7
8
NC
NC
VDD +
2OUT
2IN −
2IN +
NC
NC
1OUT
NC
VDD+
NC
NC
NC
NC
NC
NC
4
1
TLC2202
FK PACKAGE
(TOP VIEW)
NC
VDD +
NC
OUT
NC
NC
1IN −
NC
1IN +
NC
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
NC
2OUT
NC
2IN −
NC
NC
VDD − /GND
NC
2IN+
NC
NC
VDD − /GND
NC
NC
NC
NC
IN −
NC
IN +
NC
NC
NC
1OUT
1IN −
1IN +
VDD − /GND
NC
VDD +
2OUT
2IN −
2IN +
NC − No internal connection
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
equivalent schematic (each amplifier)
VDD +
Q3
Q6
Q9
Q12
Q14
Q16
IN +
OUT
C1
IN −
Q1
Q4
Q13
Q15
Q17
D1
Q7
Q8
Q10
Q11
R1
Q2
Q5
VDD − / GND
ACTUAL DEVICE COMPONENT COUNT
COMPONENT
TLC2201
TLC2202
17
34
Resistors
2
2
Diodes
1
4
Capacitors
1
2
Transistors
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
R2
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201Y chip information
This chip, when properly assembled, displays characteristics similar to the TLC2201C. Thermal compression
or ultrasonic bonding may be used on the doped-aluminum bonding path. Chips may be mounted with
conductive epoxy or a gold-silicon preform.
BONDING PAD ASSIGNMENTS
(8)
(7)
(6)
IN −
IN +
(2)
(3)
VDD+
(7)
+
(6)
OUT
−
(4)
VDD −
77
CHIP THICKNESS: 15 MILS TYPICAL
BONDING PADS: 4 × 4 MILS MINIMUM
TJmax = 150°C
TOLERANCES ARE ± 10%.
ALL DIMENSIONS ARE IN MILS.
(1)
(2)
(3)
(4)
TERMINAL NUMBERS ARE FOR THE
D, JG, AND P PACKAGES.
65
POST OFFICE BOX 655303
PIN (4) IS INTERNALLY CONNECTED
TO BACK SIDE OF CHIP.
• DALLAS, TEXAS 75265
5
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202Y chip formation
This chip, when properly assembled, displays characteristics similar to the TLC2202C. Thermal compression
or ultrasonic bonding may be used on the doped-aluminum bonding pads. Chips may be mounted with
conductive epoxy or a gold-silicon preform.
BONDING PAD ASSIGNMENTS
(8)
(7)
(6)
1IN +
(3)
(2)
1IN −
(5)
(7)
VDD+
(8)
+
(1)
1OUT
−
+
2OUT
−
(5)
(6)
2IN +
2IN −
(4)
80
VDD−
CHIP THICKNESS: 15 MILS TYPICAL
BONDING PADS: 4 × 4 MILS MINIMUM
TJmax = 150°C
(4)
TOLERANCES ARE ± 10%.
ALL DIMENSIONS ARE IN MILS.
(1)
(2)
(3)
100
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PIN (4) IS INTERNALLY CONNECTED
TO BACKSIDE OF CHIP.
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDD + (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V
Supply voltage, VDD − . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −8 V
Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 16 V
Input voltage, VI (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 8 V
Input current, II (each input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 5 mA
Output current, IO (each output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Duration of short-circuit current at (or below) 25°C (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . unlimited
Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
I suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
M suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, PS, or P package . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package . . . . . . . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values except differential voltages are with respect to the midpoint between VDD + and VDD − .
2. Differential voltages are at IN+ with respect to IN −.
3. The output may be shorted to either supply. Temperature and /or supply voltages must be limited to ensure that the maximum
dissipation rating in not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
25 C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C
TA = 70
70°C
C
POWER RATING
TA = 85
85°C
C
POWER RATING
TA = 125
125°C
C
POWER RATING
D−8
725 mW
5.8 mW/°C
464 mW
377 mW
145 mW
D−14
950 mW
7.6 mW/°C
608 mW
494 mW
190 mW
PS
770 mW
6.2 mW/°C
496 mW
403 mW
155 mW
FK
1375 mW
11.0 mW/°C
880 mW
715 mW
275 mW
JG
1050 mW
8.4 mW/°C
672 mW
546 mW
210 mW
P
1000 mW
8.0 mW/°C
640 mW
520 mW
200 mW
recommended operating conditions
C SUFFIX
MIN
Supply voltage, VDD ±
Common-mode input voltage, VIC
Operating free-air temperature, TA
± 2.3
VDD −
0
POST OFFICE BOX 655303
MAX
±8
VDD + − 2.3
70
I SUFFIX
MIN
± 2.3
VDD −
−40
• DALLAS, TEXAS 75265
MAX
±8
VDD + − 2.3
85
M SUFFIX
MIN
± 2.3
VDD −
−55
MAX
±8
VDD + − 2.3
125
UNIT
V
V
°C
7
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201C
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
VOM +
Maximum positive peak output voltage swing
600
RL = 10 kΩ
VOM −
Maximum negative peak output voltage swing
VO = ± 4 V,
AVD
1
Full range
RS = 50 Ω
RL = 500 kΩ
Large-signal differential voltage amplification
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
300
25°C
90
RL = 10 kΩ
Full range
70
VO = 0,
Full range
85
25°C
90
Full range
85
Common-mode rejection ratio
VIC = VICRmin,
RS = 50 Ω
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
25°C
µV/mo
60
pA
60
100
VO = ± 4 V,
CMRR
0.005
100
25°C
µV
V
µV/°C
V/°C
0.5
Full range
UNIT
pA
V
4.8
V
−4.9
V
560
V/mV
100
dB
110
dB
1.1
Full range
1.5
1.5
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201C operating characteristics at specified free-air temperature, VDD± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is 0°C to +70°C.
8
RL = 10 kΩ,
k ,
TA†
25°C
Full range
TLC2201C
MIN
TYP
2
2.7
MAX
UNIT
V/ s
V/µs
1.5
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.9
MHz
25°C
48°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201AC
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of input
offset voltage
Input offset voltage long-term
drift (see Note 4)
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage
range
VOM +
Maximum positive peak output
voltage swing
Full range
AVD
Maximum negative peak output
voltage swing
Large-signal differential voltage
amplification
200
RS = 50 Ω
0.5
RL = 10 kΩ
VO = ± 4 V,
VO = ± 4 V,
RL = 500 kΩ
RL = 10 kΩ
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio
(∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
80
200
60
0.5
1
60
1
−5 to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
300
25°C
90
Full range
70
25°C
90
Full range
85
25°C
90
Full range
85
25°C
Full range
4.7
−4.7
400
pA
4.8
V
−4.9
V
−4.7
560
pA
V
4.7
−4.9
µV/mo
60
100
−5 to
2.7
4.8
µV
V
60
100
100
UNIT
µV/°C
0.001 0.005
100
Full range
Full range
MAX
0.5
0.001 0.005
25°C
Full range
RS = 50 Ω
TYP
300
0.5
25°C
VOM −
80
MIN
300
25°C
IIO
MAX
Full range
VIC = 0,
TLC2201BC
TYP
560
300
100
90
V/mV
100
70
115
90
115
dB
85
110
90
110
dB
85
1.1
1.5
1.5
1.1
1.5
1.5
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C operating characteristics at specified free-air temperature, VDD± = ±5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage (see Note 5)
VN(PP)
In
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
RL = 10 kΩ,
k ,
TA†
25°C
Full range
TLC2201AC
MIN
TYP
2
2.7
TLC2201BC
MAX
1.5
MIN
TYP
2
2.7
MAX
UNIT
V/ s
V/µs
1.5
f = 10 Hz
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
Peak-to-peak equivalent input f = 0.1 to 1 Hz
noise voltage
f = 0.1 to 10 Hz
25°C
0.5
0.5
25°C
0.7
0.7
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
nV/√Hz
µV
V
φm
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
25°C
48°
48°
† Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201C
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
600
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
Full range
1
Full range
AVD
Large-signal differential voltage amplification
VO = 1 V to 4 V,
RL = 10 kΩ
CMRR
Common-mode rejection ratio
VIC = VICRmin,
RS = 50 Ω
VO = 0,
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
IDD
Supply current
VO = 2.5 V,
No load
60
V
50
50
Full range
100
25°C
25
Full range
15
25°C
90
Full range
85
25°C
90
Full range
85
25°C
pA
4.8
Full range
150
pA
V
0
25°C
µV/mo
60
100
25°C
VO = 1 V to 4 V,
RL = 500 kΩ
0.005
100
25°C
µV
V
µV/°C
0.5
IIO
UNIT
mV
315
V/mV
55
110
dB
110
dB
1
Full range
1.5
1.5
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201C operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is 0°C to +70°C.
TLC2201C
TA†
MIN
TYP
25°C
1.8
2.5
Full range
1.3
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.8
MHz
25°C
45°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
11
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201AC
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage long-term
drift (see Note 4)
Full range
80
200
RS = 50 Ω
25°C
25°C
0.5
IIB
Input bias current
VICR
Common-mode input voltage
range
RS = 50 Ω
Full range
0 to
2.7
Maximum high-level output
voltage
25°C
4.7
VOH
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output
voltage
IO = 0
Full range
VO = 1 V to 4 V,
RL = 500 kΩ
25°C
150
Full range
100
25°C
1
25
Full range
15
25°C
90
Full range
85
25°C
90
Full range
85
VDD = 4.6 V to 16 V
IDD
Supply current
VO = 2.5 V,
No load
0.001 0.005
60
0.5
1
4.8
25°C
Full range
315
pA
4.8
V
0
50
50
150
pA
V
4.7
50
µV/mo
60
100
4.7
µV
V
60
100
60
UNIT
V/°C
µV/°C
0.5
50
25°C
Supply voltage rejection ratio
(∆VDD ± /∆VIO)
200
0 to
2.7
0
VO = 1 V to 4 V,
RL = 10 kΩ
kSVR
80
100
25°C
VIC = VICRmin,
VO = 0,
RS = 50 Ω
MAX
100
Full range
Common-mode rejection ratio
TYP
300
0.001 0.005
Full range
CMRR
MIN
0.5
Input offset current
Large-signal differential
voltage amplification
MAX
300
IIO
AVD
TYP
Full range
VIC = 0,
TLC2201BC
mV
315
100
55
25
V/mV
55
15
110
90
110
dB
85
110
90
110
dB
85
1
1.5
1.5
1
1.5
1.5
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201C operating characteristics at specified free-air temperature, VDD = 5 V
TLC2201AC
TLC2201BC
PARAMETER
TEST CONDITIONS
TA†
SR
Slew rate at unity gain
VO = 0.5 V to 2.5 V,
RL = 10 kΩ, CL = 100 pF
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
Vn
f = 1 kHz
25°C
8
15
8
12
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
VN(PP)
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
1.8
1.8
MHz
Gain-bandwidth product
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
MIN
TYP
25°C
1.8
2.5
Full range
1.3
MAX
MIN
TYP
1.8
2.5
MAX
UNIT
V/ s
V/µs
1.3
nV/√Hz
µV
V
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
45°
45°
† Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202C electrical characteristics at specified free-air temperature, VDD ± = ±5 V (unless
otherwise specified)
PARAMETER
TEST CONDITIONS
TA†
TLC2202C
MIN
25°C
TYP
MAX
100
1000
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
IIO
Input offset current
IIB
Input bias current
1150
RS = 50 Ω
VOM +
Maximum positive peak output voltage swing
RL = 10 kΩ
VOM −
Maximum negative peak output voltage swing
VO = ± 4 V,
AVD
1
Full range
Common-mode input voltage range
RL = 500 kΩ
Large-signal differential voltage amplification
VO = ± 4 V,
RL = 10 kΩ
VIC = VICRmin,
CMRR
Common-mode rejection ratio
VO = 0,
RS = 50 Ω
kSVR
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
0.005
µV/mo
60
100
25°C
VICR
µV
V
µV/°C
0.5
Full range
UNIT
60
pA
100
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
300
Full range
200
25°C
50
Full range
25
25°C
80
Full range
80
25°C
80
Full range
80
V
4.8
V
−4.9
V
560
V/mV
100
115
dB
110
dB
25°C
1.8
Full range
2.7
2.7
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202C operating characteristics at specified free-air temperature, VDD± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is 0°C to +70°C.
14
RL = 10 kΩ,
TA†
TLC2202C
MIN
TYP
25°C
1.8
2.7
Full range
1.3
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
MHz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
RL = 10 kΩ,
CL = 100 pF
25°C
48°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202C electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient
of input offset voltage
Input offset voltage long-term
drift (see Note 4)
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage
range
VOM +
Maximum positive peak
output voltage swing
VOM −
Maximum negative peak
output voltage swing
AVD
Large-signal differential
voltage amplification
TEST CONDITIONS
TA†
TLC2202AC
MIN
25°C
MAX
80
500
Full range
RS = 50 Ω
25°C
0.5
25°C
VO = ± 4 V,
VO = ± 4 V,
RL = 500 kΩ
RL = 10 kΩ
500
0.5
60
100
60
1
60
100
25°C
−5
to
2.7
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
300
Full range
200
25°C
50
Full range
25
25°C
80
Full range
80
CMRR
Common-mode rejection ratio
kSVR
Supply-voltage rejection ratio
( VDD ± /∆V
(∆V
/ VIO)
VDD ± = ± 2.3 V to ± 8 V
25°C
80
Full range
80
IDD
Supply current
VO = 0,
Full range
25°C
100
−5
to
2.7
4.7
4.8
−4.7
4.8
300
−4.9
50
pA
pA
V
560
200
100
µV/mo
V
−4.7
560
µV
V
4.7
−4.9
UNIT
µV/°C
0.001 0.005
60
1
VIC = VICRmin,
VO = 0,
RS = 50 Ω
No load
80
100
Full range
RL = 10 kΩ
MAX
0.5
0.001 0.005
25°C
Full range
TYP
650
0.5
Full range
RS = 50 Ω
MIN
650
Full range
VIC = 0,
TLC2202BC
TYP
V/mV
100
25
115
80
115
dB
80
110
80
110
dB
80
1.8
2.7
1.8
2.7
2.7
2.7
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202C operating characteristics at specified free-air temperature, VDD± = ±5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
VN(PP)
Peak-to-peak equivalent input
noise voltage
In
Equivalent input noise current
Gain-bandwidth product
TLC2202AC
TEST CONDITIONS
TA†
MIN
TYP
VO = ± 2.3 V,
RL = 10 kΩ, CL = 100 pF
f = 10 Hz
25°C
1.8
2.7
Full range
1.3
TLC2202BC
MAX
MIN
TYP
1.8
2.7
MAX
UNIT
V/ s
V/µs
1.3
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
25°C
0.6
0.6
fA/√Hz
25°C
25
C
1.9
1.9
MHz
kΩ
f = 10 kHz, RL = 10 kΩ,
CL = 100 pF
nV/√Hz
µV
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
48°
48°
† Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
15
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2202C
MIN
TYP
MAX
100
1000
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
1150
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
1
Full range
pA
4.8
V
0
50
50
25°C
150
Full range
100
VO = 1 V to 4 V,
RL = 10 kΩ
25°C
25
Full range
15
25°C
75
Full range
75
CMRR
Common-mode rejection ratio
VO = 0,
RS = 50 Ω
25°C
80
kSVR
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD= 4.6 V to 16 V
Full range
80
IDD
Supply current
VO = 0,
Full range
mV
315
V/mV
55
110
dB
110
dB
25°C
No load
60
V
Full range
VIC = VICRmin,
pA
100
25°C
Large-signal differential voltage amplification
60
µV/mo
100
25°C
AVD
0.005
Full range
VO =1 V to 4 V,
RL = 500 kΩ
µV
V
µV/°C
0.5
IIO
UNIT
1.7
2.6
2.6
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202C operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is 0°C to +70°C.
16
TA†
TLC2202C
MIN
TYP
25°C
1.6
2.5
Full range
1.1
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
nV/√Hz
µV
V
25°C
0.6
fA/√Hz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
MHz
RL = 10 kΩ,
CL = 100 pF
25°C
47°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient
of input offset voltage
Input offset voltage
long-term drift (see Note 4)
TEST CONDITIONS
TA†
TLC2202AC
MIN
25°C
MAX
80
500
Full range
RS = 50 Ω
MAX
80
500
25°C
0.5
IIB
Input bias current
VICR
Common-mode input
voltage range
RS = 50 Ω
Full range
0
to
2.7
VOH
Maximum high-level
output voltage
RL = 10 kΩ
25°C
4.7
Full range
4.7
VOL
Maximum low-level
output voltage
IO = 0
Full range
150
AVD
VO = 1 V to 4 V,
RL = 500 kΩ
25°C
Large-signal differential
voltage amplification
Full range
100
25°C
25
Full range
15
25°C
75
0.001 0.005
60
Full range
0.5
60
100
25°C
1
100
60
Full range
1
60
100
25°C
100
0
to
2.7
4.8
4.7
50
4.8
0
50
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
Full range
75
kSVR
Supply-voltage rejection ratio
(∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
25°C
80
Full range
80
IDD
Supply current
VO = 2.5 V,
Full range
25°C
50
150
25
pA
pA
mV
315
100
55
µV/mo
V
50
315
µV
V
4.7
0
UNIT
µV/°C
0.5
0.001 0.005
25°C
Input offset current
No load
TYP
650
0.5
IIO
VO = 1 V to 4 V,
RL = 10 kΩ
MIN
650
Full range
VIC = 0,
TLC2202BC
TYP
V/mV
55
15
110
75
110
dB
75
110
80
110
dB
80
1.7
2.6
1.7
2.6
2.6
2.6
mA
† Full range is 0°C to +70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202C operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TLC2202AC
TEST CONDITIONS
TA†
MIN
TYP
VO = 0.5 V to 2.5 V,
RL = 10 kΩ, CL = 100 pF
25°C
1.6
2.5
Full range
1.1
TLC2202BC
MAX
MIN
TYP
1.6
2.5
MAX
UNIT
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
VN(PP)
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
25
C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz, RL = 10 kΩ,
kΩ
CL = 100 pF
V/ s
V/µs
1.1
nV/√Hz
µV
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
47°
47°
† Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I electrical characteristics at specified free-air temperature, VDD ± = ±5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201I
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
VOM +
Maximum positive peak output voltage swing
650
RL = 10 kΩ
VOM −
Maximum negative peak output voltage swing
VO = ± 4 V,
AVD
1
Full range
RS = 50 Ω
RL = 500 kΩ
Large-signal differential voltage amplification
VO = ± 4 V,
RL = 10 kΩ
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
0.005
−5
to
2.7
25°C
4.7
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
250
25°C
90
Full range
65
25°C
90
85
25°C
90
Full range
85
25°C
pA
V
Full range
Full range
pA
60
150
Full range
µV/mo
60
150
25°C
µV
V
µV/°C
V/°C
0.5
Full range
UNIT
4.8
V
−4.9
V
560
V/mV
100
115
dB
110
dB
1.1
Full range
1.5
1.5
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201I operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 40°C to +85°C.
18
RL = 10 kΩ,
k ,
TLC2201I
TA†
MIN
TYP
25°C
2
2.7
Full range
MAX
UNIT
V/ s
V/µs
1.4
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.9
MHz
25°C
48°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise
noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient of input
offset voltage
Input offset voltage long-term
drift (see Note 4)
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage
range
VOM +
Maximum positive peak output
voltage swing
VOM −
Maximum negative peak output
voltage swing
AVD
Large-signal differential voltage
amplification
CMRR Common-mode rejection ratio
TEST CONDITIONS
TA†
TLC2201AI
MIN
25°C
TYP
MAX
80
200
Full range
RS = 50 Ω
25°C
0.5
1
Full range
VO = ± 4 V,
VO = ± 4 V,
RL = 500 kΩ
RL = 10 kΩ
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio
(∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
80
200
60
0.5
1
150
−5 to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
250
25°C
90
Full range
65
25°C
90
Full range
85
25°C
90
Full range
85
25°C
Full range
60
150
60
60
150
−5 to
2.7
4.8
4.7
−4.7
4.8
400
−4.9
90
pA
pA
V
560
250
100
µV/mo
V
−4.7
560
µV
V
4.7
−4.9
UNIT
µV/°C
0.001 0.005
150
25°C
RL = 10 kΩ
MAX
0.5
0.001 0.005
Full range
Full range
TYP
350
0.5
25°C
RS = 50 Ω
MIN
350
Full range
VIC = 0,
TLC2201BI
V/mV
100
65
115
90
115
dB
85
110
90
110
dB
85
1.1
1.5
1.5
1.1
1.5
1.5
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25°C using the Arrhenius equation assuming an activation energy of 0.96 eV.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
19
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I operating characteristics at specified free-air temperature, VDD ± = ±5 V
TLC2201AI
TLC2201BI
PARAMETER
TEST CONDITIONS
TA†
SR
Slew rate at unity gain
VO = ± 2.3 V,
RL = 10 kΩ, CL = 100 pF
Full range
Vn
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
VN(PP)
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
CL = 100 pF
25°C
MIN
TYP
2
2.7
MAX
1.4
MIN
TYP
2
2.7
MAX
UNIT
V/µs
1.4
nV/√Hz
µV
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
48°
48°
† Full range is − 40°C to +85°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
20
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201I
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
650
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
Full range
1
Full range
AVD
Large-signal differential voltage amplification
Full range
100
25°C
25
Full range
15
25°C
90
Full range
85
25°C
90
Full range
85
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
IDD
Supply current
VO = 2.5 V,
No load
pA
V
50
50
VO = 1 V to 4 V,
RL = 10 kΩ
CMRR
60
4.8
Full range
150
pA
V
0
25°C
µV/mo
60
150
25°C
VO = 1 V to 4 V,
RL = 500 kΩ
0.005
150
25°C
µV
V
µV/°C
0.5
IIO
UNIT
mV
315
V/mV
55
110
dB
110
dB
25°C
1
Full range
1.5
1.5
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201I operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 40°C to +85°C.
TLC2201I
TA†
MIN
TYP
25°C
1.8
2.5
Full range
1.2
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.8
MHz
25°C
45°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
21
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage long-term
drift (see Note 4)
TEST CONDITIONS
TA†
TLC2201AI
MIN
25°C
Full range
RS = 50 Ω
200
25°C
0.5
Input bias current
VICR
Common-mode input voltage
range
RS = 50 Ω
Full range
VOH
Maximum high-level output
voltage
RL = 10 kΩ
25°C
0
to
2.7
4.7
Full range
4.7
VOL
Maximum low-level output
voltage
IO = 0
Full range
Full range
25°C
1
VO = 0,
RS = 50 Ω
200
0.001 0.005
60
0.5
1
150
Full range
100
25°C
25
Full range
15
25°C
90
Full range
85
Supply voltage rejection ratio
( VDD ± /∆V
(∆V
/ VIO)
VDD = 4.6 V to 16 V
25°C
90
Full range
85
IDD
Supply current
VO = 2.5 V,
Full range
25°C
60
150
0
to
2.7
4.7
4.8
315
0
50
50
150
25
pA
pA
mV
315
100
55
µV/mo
V
4.7
50
µA
V
50
25°C
60
150
60
UNIT
µV/°C
0.5
4.8
0
kSVR
No load
80
150
25°C
VO = 1 V to 4 V,
RL = 10 kΩ
k
VIC = VICRmin,
MAX
150
Full range
VO = 1 V to 4 V,
RL = 500 kkΩ
TYP
350
0.001 0.005
25°C
IIB
CMRR Common-mode rejection ratio
80
MIN
0.5
Input offset current
Large-signal differential
voltage amplification
MAX
350
IIO
AVD
TYP
Full range
VIC = 0,
TLC2201BI
V/mV
55
15
110
90
110
dB
85
110
90
110
dB
85
1
1.5
1.5
1
1.5
1.5
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
22
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201I operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise
voltage (see Note 5)
VN(PP)
In
TEST CONDITIONS
TA†
VO = 0.5 V to 2.5 V,
RL = 10 kΩ, CL = 100 pF
f = 10 Hz
TLC2201AI
MIN
TYP
25°C
1.8
2.5
Full range
1.2
TLC2201BI
MAX
MIN
TYP
1.8
2.5
MAX
UNIT
V/ s
V/µs
1.2
25°C
18
35
18
30
25°C
8
15
8
12
Peak-to-peak equivalent input f = 0.1 to 1 Hz
noise voltage
f = 0.1 to 10 Hz
25°C
0.5
0.5
25°C
0.7
0.7
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
1.8
1.8
MHz
Gain-bandwidth product
f = 1 kHz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
nV/√Hz
µV
V
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
45°
45°
† Full range is − 40°C to +85°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
23
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202I electrical characteristics at specified free-air temperature, VDD ± = ±5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2202I
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
MAX
100
1000
Full range
1200
Full range
Input offset voltage long-term drift (see Note 4)
RS = 50 Ω
VIC = 0,
IIO
TYP
Input offset current
25°C
0.001
0.005
25°C
0.5
60
Input bias current
VICR
Common-mode input voltage range
VOM +
Maximum positive peak output voltage swing
RL = 10 kΩ
VOM −
AVD
1
Full range
RS = 50 Ω
Maximum negative peak output voltage swing
VO = ± 4 V,
RL = 500 kΩ
VO = ± 4 V,
RL = 10 kΩ
Large-signal differential voltage amplification
VIC = VICRmin,
pA
60
pA
150
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
300
Full range
150
25°C
50
Full range
25
25°C
80
Full range
80
CMRR
Common-mode rejection ratio
VO = 0,
RS = 50 Ω
80
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD = ± 2.3 V to ± 8 V
25°C
kSVR
Full range
80
IDD
Supply current
VO = 0,
Full range
25°C
No load
µV/mo
150
25°C
IIB
µV
V
µV/°C
0.5
Full range
UNIT
V
4.8
V
−4.9
V
560
V/mV
100
115
dB
110
dB
1.8
2.7
2.7
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202I operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 40°C to +85°C.
24
RL = 10 kΩ,
TA†
TLC2202I
MIN
TYP
25°C
1.8
2.7
Full range
1.2
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
nV/√Hz
µV
V
25°C
0.6
fA/√Hz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
MHz
RL = 10 kΩ,
CL = 100 pF
25°C
48°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202I electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise
noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient
of input offset voltage
Input offset voltage long-term
drift (see Note 4)
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input
voltage range
VOM +
Maximum positive peak
output voltage swing
VOM −
Maximum negative peak
output voltage swing
AVD
Large-signal differential
voltage amplification
TEST CONDITIONS
TA†
TLC2202AI
MIN
25°C
MAX
80
500
Full range
RS = 50 Ω
0.5
1
0.5
60
150
60
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
1
60
25°C
−4.7
Full range
−4.7
25°C
300
Full range
150
25°C
50
Full range
25
25°C
80
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
Full range
80
kSVR
Supply-voltage rejection ratio
(∆VDD ± /∆VIO)
VDD ± ± 2.3 V to ± 8 V
25°C
80
Full range
80
IDD
Supply current
VO = 0,
Full range
25°C
150
−5
to
2.7
4.8
4.7
−4.7
4.8
300
−4.9
50
pA
pA
V
560
150
100
µV/mo
V
−4.7
560
µV
V
4.7
−4.9
UNIT
µV/°C
150
CMRR
No load
500
0.001 0.005
60
Full range
VO = ± 4 V,
RL = 10 kΩ
80
150
25°C
VO = ± 4 V,
RL = 500 kΩ
MAX
0.5
0.001 0.005
25°C
25°C
RL = 10 kΩ
TYP
700
0.5
Full range
RS = 50 Ω
MIN
700
Full range
VIC = 0,
TLC2202BI
TYP
V/mV
100
25
115
80
115
dB
80
110
80
110
dB
80
1.8
2.7
1.8
2.7
2.7
2.7
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202I operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
TLC2202AI
TEST CONDITIONS
TA†
MIN
TYP
VO = ± 2.3 V, RL = 10 kΩ,
CL = 100 pF
25°C
1.8
2.7
Full range
1.2
TLC2202BI
MAX
MIN
TYP
1.8
2.7
MAX
UNIT
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
VN(PP)
Peak-to-peak equivalent
input noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
25
C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz, RL = 10 kΩ,
kΩ
CL = 100 pF
V/ s
V/µs
1.2
nV/√Hz
µV
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
48°
48°
† Full range is − 40°C to +85°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
25
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2202I
MIN
25°C
TYP
MAX
100
1000
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
1200
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
Full range
1
Full range
Large-signal differential voltage amplification
60
pA
4.8
V
0
50
50
25°C
150
Full range
100
VO = 1 V to 4 V,
RL = 10 kΩ
25°C
25
Full range
15
25°C
75
Full range
75
CMRR
Common-mode rejection ratio
VO = 0,
RS = 50 Ω
25°C
80
kSVR
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD= 4.6 V to 16 V
Full range
80
IDD
Supply current
VO = 2.5 V,
Full range
mV
315
V/mV
55
110
dB
110
dB
25°C
No load
pA
V
Full range
VIC = VICRmin,
60
µV/mo
150
25°C
AVD
0.005
150
25°C
VO =1 V to 4 V,
RL = 500 kΩ
µV
V
µV/°C
0.5
IIO
UNIT
1.7
2.6
2.6
mA
† Full range is − 40°C to +85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202I operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 40°C to +85°C.
26
TEST CONDITIONS
TA†
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
Full range
25°C
TLC2202I
MIN
TYP
1.6
2.5
MAX
UNIT
V/ s
V/µs
1
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
MHz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
RL = 10 kΩ,
CL = 100 pF
25°C
47°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage long-term
drift (see Note 4)
TEST CONDITIONS
TA†
TLC2202AI
MIN
25°C
Full range
500
RS = 50 Ω
0.001 0.005
25°C
25°C
0.5
IIB
Input bias current
80
500
VICR
Common-mode input
voltage range
RS = 50 Ω
Full range
0
to
2.7
VOH
Maximum high-level output
voltage
RL = 10 kΩ
25°C
4.7
Full range
4.7
VOL
Maximum low-level output
voltage
IO = 0
Full range
VO = 1 V to 4 V,
RL = 500 kΩ
25°C
150
Full range
100
25°C
25
Full range
15
0.001 0.005
60
25°C
1
0.5
60
150
60
1
60
150
25°C
150
0
to
2.7
4.8
4.7
50
4.8
0
50
25°C
75
Full range
75
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply-voltage rejection ratio
(∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
25°C
80
Full range
80
IDD
Supply current
VO = 2.5 V,
Full range
25°C
50
150
25
pA
pA
mV
315
100
55
µV/mo
V
50
315
µV
V
4.7
0
UNIT
µV/°C
150
Full range
No load
MAX
0.5
Full range
VO =1 V to 4 V,
RL = 10 kΩ
TYP
700
0.5
Input offset current
Large-signal differential
voltage amplification
80
MIN
700
IIO
AVD
MAX
Full range
VIC = 0,
TLC2202BI
TYP
V/mV
55
15
110
75
110
dB
75
110
80
110
dB
80
1.7
2.6
1.7
2.6
2.6
2.6
mA
† Full range is − 40°C to +85°C
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202I operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TLC2202AI
TEST CONDITIONS
TA†
MIN
TYP
VO = 0.5 V to 2.5 V,
RL = 10 kΩ, CL = 100 pF
25°C
1.6
2.5
TLC2202BI
MAX
MIN
TYP
1.6
2.5
MAX
UNIT
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
VN(PP)
Peak-to-peak equivalent
input noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
25°C
25
C
1.9
1.9
MHz
Gain-bandwidth product
kΩ
f = 10 kHz, RL = 10 kΩ,
CL = 100 pF
Full range
1
V/ s
V/µs
1
nV/√Hz
µV
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
47°
47°
† Full range is − 40°C to +85°C
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
27
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M electrical characteristics at specified free-air temperature, VDD ± = ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201M
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
VOM +
Maximum positive peak output voltage swing
700
RL = 10 kΩ
VOM −
Maximum negative peak output voltage swing
VO = ± 4 V,
AVD
1
Full range
RS = 50 Ω
RL = 500 kΩ
Large-signal differential voltage amplification
VO = ± 4 V,
RL = 10 kΩ
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
0.005
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
200
25°C
90
Full range
45
25°C
90
Full range
85
25°C
90
Full range
85
pA
60
500
Full range
µV/mo
60
500
25°C
µV
V
µV/°C
0.5
Full range
UNIT
pA
V
4.8
V
−4.9
V
560
V/mV
100
115
dB
110
dB
25°C
1.1
Full range
1.5
1.5
mA
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201M operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin
† Full range is − 55°C to 125°C.
28
RL = 10 kΩ,
k ,
TLC2201M
TA†
MIN
TYP
25°C
2
2.7
Full range
MAX
UNIT
V/ s
V/µs
1.3
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.9
MHz
25°C
48°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
V
µV
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
TA†
TEST CONDITIONS
TLC2201AM
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage
long-term drift (see Note 4)
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input
voltage range
VOM+
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
AVD
Large-signal differential
voltage amplification
Common-mode rejection
CMRR
ratio
MAX
80
200
Full range
RS = 50 Ω
25°C
0.001
25°C
0.5
VO = ± 4 V,
RL = 500 kΩ
VO = ± 4 V,
RL = 10 kΩ
1
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
400
Full range
200
25°C
90
Full range
45
25°C
90
Full range
85
25°C
90
Full range
85
Supply voltage rejection
ratio (∆VDD ± /∆VIO)
VDD ± = ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
80
200
0.005
0.001
60
0.5
25°C
Full range
0.005
1
4.7
−4.7
400
pA
4.8
V
−4.9
V
−4.7
560
pA
V
4.7
−4.9
µV/mo
60
500
−5
to
2.7
4.8
µV
V
60
500
60
UNIT
V/°C
µV/°C
0.5
500
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
MAX
500
Full range
RL = 10 kΩ
TYP
400
0.5
Full range
RS = 50 Ω
MIN
400
25°C
VOM −
TYP
Full range
VIC = 0,
TLC2201BM
560
200
100
90
V/mV
100
45
115
90
115
dB
85
110
90
110
dB
85
1.1
1.5
1.5
1.1
1.5
1.5
mA
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observable through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
29
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
VN(PP)
Peak-to-peak equivalent input
noise voltage
In
Equivalent input noise current
φm
TEST
CONDITIONS
VO = ± 2.3 V,
RL = 10 kΩ,
CL = 100 pF
f = 10 Hz
TA†
25°C
Full range
TLC2201AM
MIN
TYP
2
2.7
TLC2201BM
MAX
1.3
MIN
TYP
2
2.7
MAX
UNIT
V/ s
V/µs
1.3
25°C
18
35
18
30
f = 1 kHz
25°C
8
15
8
12
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
25°C
0.6
0.6
fA/√Hz
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
CL = 100 pF
25°C
25
C
1.9
1.9
MHz
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
25°C
48°
48°
nV/√Hz
µV
V
† Full range is − 55°C to 125°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
30
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201M
MIN
25°C
TYP
MAX
100
500
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
700
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
1
Full range
4.8
V
Large-signal differential voltage amplification
Full range
75
VO = 1 V to 4 V,
RL = 10 kΩ
25°C
25
Full range
10
25°C
90
Full range
85
25°C
90
Full range
85
CMRR
Common-mode rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
IDD
Supply current
VO = 2.5 V,
No load
50
50
150
pA
V
0
25°C
pA
60
500
Full range
VO = 1 V to 4 V,
RL = 500 kΩ
µV/mo
60
500
25°C
AVD
0.005*
Full range
25°C
µV
V
µV/°C
0.5
IIO
UNIT
mV
315
V/mV
55
110
dB
110
dB
25°C
1
Full range
1.5
1.5
mA
∗On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201M operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
f = 10 Hz
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 55°C to 125°C.
TLC2201M
TA†
MIN
TYP
25°C
1.8
2.5
Full range
1.1
MAX
UNIT
V/ s
V/µs
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
25°C
0.6
fA/√Hz
25°C
1.8
MHz
25°C
45°
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
nV/√Hz
µV
V
31
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TA†
TEST CONDITIONS
TLC2201AM
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage
long-term drift (see Note 4)
MAX
80
200
Full range
RS = 50 Ω
25°C
0.001
25°C
0.5
IIB
Input bias current
VICR
Common-mode input
voltage range
RS = 50 Ω
Full range
0
to
2.7
Maximum high-level output
voltage
25°C
4.7
VOH
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output
voltage
IO = 0
Full range
150
Full range
75
AVD
VO = 1 V to 4 V,
RL = 500 kΩ
25°C
Large-signal differential
voltage amplification
25°C
25
Full range
10
Full range
25°C
1
90
Full range
85
25°C
90
Full range
85
Supply current
VO = 2.5 V,
No load
0.005
0.001
60
0.5
25°C
Full range
0.005
1
4.8
315
pA
4.8
V
0
50
50
150
pA
V
4.7
50
µV/mo
60
500
4.7
µV
V
60
500
60
UNIT
V/°C
µV/°C
0.5
50
25°C
IDD
200
0
to
2.7
0
VIC = VICRmin,
VO = 0,
RS = 50 Ω
VDD = 4.6 V to 16 V
80
500
25°C
Supply voltage rejection
ratio (∆VDD ± /∆VIO)
MAX
500
Full range
kSVR
TYP
400
0.5
Input offset current
VO = 1 V to 4 V,
RL = 10 kΩ
MIN
400
IIO
Common-mode rejection
CMRR
ratio
TYP
Full range
VIC = 0,
TLC2201BM
V
315
75
55
25
V/mV
55
10
110
90
110
dB
85
110
90
110
dB
85
1.1
1.5
1.5
1.1
1.5
1.5
mA
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observable through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
32
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201M operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
SR
Slew rate at unity gain
TEST CONDITIONS
TA†
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
TLC2201AM
MIN
TYP
25°C
1.8
2.5
Full range
1.1
TLC2201BM
MAX
MIN
TYP
1.8
2.5
MAX
UNIT
V/ s
V/µs
1.1
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35
18
30
Vn
f = 1 kHz
25°C
8
15
8
12
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
VN(PP)
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
MHz
φm
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
CL = 100 pF
25°C
25
C
1.8
1.8
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
25°C
45°
45°
nV/√Hz
µV
V
† Full range is − 55°C to 125°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
33
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2202M
MIN
25°C
TYP
MAX
100
1000
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
0.001
25°C
0.5
Full range
RS = 50 Ω
VIC = 0,
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
VOM +
Maximum positive peak output voltage swing
1250
VOM −
AVD
1
Full range
RL = 10 kΩ
Maximum negative peak output voltage swing
Large-signal differential voltage amplification
VO =1 V to 4 V,
RL = 500 kΩ
Full range
−5
to
2.7
25°C
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
300
Full range
100
25°C
50
Full range
25
25°C
80
Full range
80
25°C
80
Full range
80
Common-mode rejection ratio
VO = 0,
RS = 50 Ω
VIC = VICRmin,
kSVR
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD= ± 2.3 V to ± 8 V
IDD
Supply current
VO = 0,
No load
60
µV/mo
pA
60
pA
500
VO = 1 V to 4 V,
RL = 10 kΩ
CMRR
0.005
500
25°C
RS = 50 Ω
µV
V
µV/°C
0.5
Full range
UNIT
V
4.8
V
−4.9
V
560
V/mV
100
115
dB
110
dB
25°C
1.8
Full range
2.7
2.7
mA
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202M operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
TEST CONDITIONS
VO = ± 2.3 V,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 55°C to 125°C.
34
RL = 10 kΩ,
TA†
TLC2202M
MIN
TYP
25°C
1.8
2.7
Full range
1.1
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
nV/√Hz
µV
V
25°C
0.6
fA/√Hz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
MHz
RL = 10 kΩ,
CL = 100 pF
25°C
48°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
VIO
Input offset voltage
αVIO
Temperature coefficient
of input offset voltage
Input offset voltage
long-term drift (see Note 4)
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode input
voltage range
AVD
Large-signal differential
voltage amplification
TLC2202AM
MIN
MAX
80
500
25°C
RS = 50 Ω
25°C
0.5
25°C
VO = ± 4 V,
RL = 500 kkΩ
VO = ± 4 V,
RL = 10 kΩ
80
500
60
0.5
1
25°C
−5
to
2.7
4.7
Full range
4.7
25°C
−4.7
Full range
−4.7
25°C
300
Full range
100
25°C
50
Full range
25
25°C
80
CMRR
Common-mode rejection
ratio
VO = 0, VIC = VICRmin,
RS = 50 Ω
Full range
80
kSVR
Supply-voltage rejection
ratio (∆V
( VDD ± /∆V
/ VIO)
VDD ± = ± 2.3 V to ± 8 V
25°C
80
Full range
80
4.8
60
1
−5
to
2.7
4.7
−4.7
300
4.8
−4.9
50
µV/mo
pA
pA
V
V
560
100
100
µV
V
−4.7
560
60
500
4.7
−4.9
60
500
500
UNIT
µV/°C
0.001 0.005*
500
Full range
RL = 10 kΩ
MAX
0.5
0.001 0.005*
25°C
Full range
TYP
750
0.5
Full range
RS = 50 Ω
MIN
750
Full range
VIC = 0,
TLC2202BM
TYP
Full range
Maximum positive peak
VOM +
output voltage swing
Maximum negative peak
VOM −
output voltage swing
TA†
TEST CONDITIONS
100
V/mV
25
115
80
115
80
110
80
80
110
dB
dB
25°C
1.8
2.7
1.8
2.7
mA
Full range
2.7
2.7
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
IDD
Supply current
VO = 0,
No load
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
35
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M operating characteristics at specified free-air temperature, VDD ± = ±5 V
PARAMETER
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
(see Note 5)
VN(PP)
Peak-to-peak equivalent input
noise voltage
In
Equivalent input noise current
φm
TLC2202AM
TEST CONDITIONS
TA†
MIN
TYP
VO = ± 2.3 V,
RL = 10 kΩ,
CL = 100 pF
f = 10 Hz
25°C
1.8
2.7
Full range
1.1
TLC2202BM
MAX
MIN
TYP
1.8
2.7
MAX
UNIT
V/ s
V/µs
1.1
25°C
18
35*
18
30*
f = 1 kHz
25°C
8
15*
8
12*
f = 0.1 to 1 Hz
25°C
0.5
0.5
f = 0.1 to 10 Hz
25°C
0.7
0.7
25°C
0.6
0.6
fA/√Hz
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
CL = 100 pF
25°C
25
C
1.9
1.9
MHz
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
25°C
48°
48°
nV/√Hz
µV
V
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
36
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M electrical characteristics at specified free-air temperatures, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2202M
MIN
TYP
MAX
100
1000
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of input offset voltage
Full range
Input offset voltage long-term drift (see Note 4)
25°C
Full range
RS = 50 Ω
VIC = 0,
1250
25°C
0.5
Input offset current
IIB
Input bias current
VICR
Common-mode input voltage range
RS = 50 Ω
Full range
0
to
2.7
25°C
4.7
VOH
Maximum high-level output voltage
RL = 10 kΩ
Full range
4.7
VOL
Maximum low-level output voltage
IO = 0
Full range
1
Full range
Large-signal differential voltage amplification
V
25°C
150
Full range
75
25
Full range
10
25°C
75
Full range
75
25°C
80
Full range
80
kSVR
Supply-voltage rejection ratio (∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
IDD
Supply current
VO = 2.5 V,
No load
50
50
25°C
VIC = VICRmin, RS = 50 Ω
pA
4.8
0
VO = 1 V to 4 V,
RL = 10 kΩ
Common-mode rejection ratio
60
V
Full range
CMRR
pA
500
25°C
AVD
60
µV/mo
500
25°C
VO = 1 V to 4 V,
RL = 500 kΩ
µV
V
µV/°C
0.5
0.001 0.005*
IIO
UNIT
mV
315
V/mV
55
110
dB
110
dB
25°C
1.7
Full range
2.6
2.6
mA
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202M operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
SR
Slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
Gain-bandwidth product
φm
Phase margin at unity gain
† Full range is − 55°C to 125°C.
TA†
TLC2202M
MIN
TYP
25°C
1.6
2.5
Full range
0.9
MAX
UNIT
V/ s
V/µs
f = 10 Hz
25°C
18
f = 1 kHz
25°C
8
f = 0.1 to 1 Hz
25°C
0.5
f = 0.1 to 10 Hz
25°C
0.7
nV/√Hz
µV
V
25°C
0.6
fA/√Hz
f = 10 kHz,
CL = 100 pF
RL = 10 kΩ,
25°C
1.9
MHz
RL = 10 kΩ,
CL = 100 pF
25°C
47°
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
37
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TA†
TEST CONDITIONS
TLC2202AM
MIN
25°C
VIO
Input offset voltage
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage
long-term drift (see Note 4)
TYP
MAX
80
500
Full range
RS = 50 Ω
25°C
MAX
80
500
25°C
0.5
IIB
Input bias current
VICR
Common-mode input
voltage range
RS = 50 Ω
VOH
Maximum high-level output
voltage
RL = 10 kΩ
VOL
Maximum low-level output
voltage
IO = 0
Full range
150
Full range
75
AVD
VO = 1 V to 4 V,
RL = 500 kΩ
25°C
Large-signal differential
voltage amplification
25°C
25
Full range
10
25°C
75
Full range
0.001 0.005*
60
0.5
500
25°C
1
Full range
60
1
Full range
0
to
2.7
25°C
4.7
Full range
4.7
25°C
4.7
50
V
0
CMRR
Common-mode rejection
ratio
VO = 0, VIC = VICRmin,
RS = 50 Ω
Full range
75
Supply-voltage rejection
ratio (∆VDD ± /∆VIO)
25°C
80
kSVR
VDD = 4.6 V to 16 V
Full range
80
IDD
Supply current
VO = 2.5 V,
Full range
25°C
50
50
150
pA
4.8
50
315
pA
V
4.7
0
µV/mo
60
500
0
to
2.7
4.8
µV
V
60
500
500
UNIT
µV/°C
V/°C
0.5
0.001 0.005*
Input offset current
No load
TYP
750
0.5
IIO
VO = 1 V to 4 V,
RL = 10 kΩ
MIN
750
Full range
VIC = 0,
TLC2202BM
mV
315
75
55
25
V/mV
55
10
110
75
110
dB
75
110
80
110
dB
80
1.7
2.6
2.6
1.7
2.6
2.6
mA
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
38
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202M operating characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
SR
Slew rate at unity gain
TLC2202AM
TEST CONDITIONS
TA†
MIN
TYP
VO = 0.5 V to 2.5 V,
RL = 10 kΩ,
CL = 100 pF
25°C
1.6
2.5
Full range
0.9
TLC2202BM
MAX
MIN
TYP
1.6
2.5
MAX
UNIT
V/ s
V/µs
1.1
Equivalent input noise voltage
(see Note 5)
f = 10 Hz
25°C
18
35*
18
30*
Vn
f = 1 kHz
25°C
8
15*
8
12*
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 1 Hz
25°C
0.5
0.5
VN(PP)
f = 0.1 to 10 Hz
25°C
0.7
0.7
In
Equivalent input noise current
25°C
0.6
0.6
fA/√Hz
MHz
φm
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
CL = 100 pF
25°C
25
C
1.9
1.9
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
25°C
47°
47°
nV/√Hz
µV
V
* On products compliant to MIL-PRF-38535, Class B, this parameter is not production tested.
† Full range is − 55°C to 125°C
NOTE 5: This parameter is tested on a sample basis for the TLC2202A and on all devices for the TLC2202B. For other test requirements, please
contact the factory. This statement has no bearing on testing or nontesting of other parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
39
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2201Y electrical characteristics at VDD± = ±5 V, TA = 25°C (unless otherwise noted)
TLC2201Y
PARAMETER
VIO
TEST CONDITIONS
MIN
Input offset voltage
TYP
MAX
µV
100
Input offset voltage long-term drift (see Note 4)
VIC = 0,
IIO
IIB
Input offset current
VOH
VOL
Maximum high-level output voltage
RL = 10 kΩ
Maximum low-level output voltage
IO = 0
VO = 1 V to 4 V,
Input bias current
AVD
Large-signal differential voltage amplification
CMRR
Common-mode rejection ratio
VO = 1 V to 4 V,
VIC = VICRmin,
RS = 50 Ω
µV/mo
0.001
RS = 50 Ω
0.5
pA
1
pA
4.8
V
0
RL = 500 Ω
55
RL = 10 Ω
55
VO = 0,
UNIT
mV
V/mV
110
dB
kSVR
Supply voltage rejection ratio (∆VDD ± /∆VIO)
VDD = 4.6 to 16 V
110
dB
IDD
Supply current per amplifier
VO = 2.5 V,
No load
1
mA
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201Y operating characteristics at VDD ± = ± 5 V, TA = 25°C
PARAMETER
SR
Positive slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise
voltage
In
Equivalent input noise current
φm
40
TLC2201Y
TEST CONDITIONS
VO = ± 0.5 to 2.5 V,
f = 10 Hz
RL = 10 kΩ,
MIN
CL = 100 pF
TYP
2.5
UNIT
V/µs
18
f = 1 kHz
8
f = 0.1 to 1 Hz
0.5
f = 0.1 to 10 Hz
0.7
Gain-bandwidth product
f = 10 kHz,
RL = 10 kΩ,
Phase margin at unity gain
RL = 10 kΩ,
CL = 100 pF
POST OFFICE BOX 655303
MAX
• DALLAS, TEXAS 75265
CL = 100 pF
nV/√Hz
µV
V
0.6
pA/√Hz
1.8
MHz
48°
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TLC2202Y electrical characteristics, VDD = 5 V, TA = 25°C (unless otherwise noted)
TLC2202Y
PARAMETER
VIO
TEST CONDITIONS
MIN
Input offset voltage
TYP
MAX
µV
100
Input offset voltage long-term drift (see Note 4)
Input offset current
VOH
VOL
Maximum high-level output voltage
RL = 10 kΩ
Maximum low-level output voltage
IO = 0
VO = 1 V to 4 V,
Input bias current
AVD
Large-signal differential voltage amplification
CMRR
Common-mode rejection ratio
kSVR
Supply-voltage rejection ratio (∆VDCC /∆VIO)
VO = 1 V to 4 V,
VO = 0, VICRmin,
µV/mo
0.001
RS = 50 Ω
VIC = 0,
IIO
IIB
UNIT
0.5
pA
1
pA
4.8
V
0
mV
RL = 500 Ω
315
RL = 10 Ω
55
RS = 50 Ω
110
dB
110
dB
VDD = 4.6 to 16 V
VO = 2.5 V,
V/mV
IDD
Supply current
No load
1.7
mA
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2202Y operating characteristics at VDD = 5 V, TA = 25°C
PARAMETER
TEST CONDITIONS
VO = 0.5 V to 2.5 V,
CL = 100 pF
f = 10 Hz
SR
Positive slew rate at unity gain
Vn
Equivalent input noise voltage
VN(PP)
Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
B1
Gain-bandwidth product
f = 10 kHz,
CL = 100 pF
φm
Phase margin at unity gain
RL = 10 kΩ,
RL = 10 kΩ,
TLC2202Y
MIN
TYP
2.5
UNIT
V/µs
18
f = 10 kHz
8
f = 0.1 to 1 Hz
0.5
f = 0.1 to 10 Hz
0.7
POST OFFICE BOX 655303
MAX
nV/√Hz
µV
V
0.6
pA/√Hz
RL = 10 kΩ,
1.9
MHz
CL = 100 pF
47°
• DALLAS, TEXAS 75265
41
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
PARAMETER MEASUREMENT INFORMATION
10 kΩ
VDD +
2 kΩ
VI
VDD +
−
+
VO
VDD −
VO
CL
(see Note A)
VDD − /GND
20 Ω
20 Ω
−
+
100 Ω
RL
NOTE A: CL includes fixture capacitance.
Figure 1. Noise-Voltage Test Circuit
Figure 2. Phase-Margin Test Circuit
VDD +
VI
−
+
VO
Ground Shield
VDD −
CL
(see Note A)
VDD +
−
+
RL
VO
VDD − /GND
pA
pA
NOTE A: CL includes fixture capacitance.
Figure 3. Slew-Rate Test Circuit
Figure 4. Input-Bias and Offset-Current Test Circuit
typical values
Typical values presented in this data sheet represent the median (50% point) of device parametric performance.
input bias and offset current
At the picoamp bias current level of the TLC220x, TLC220xA, and TLC220xB, accurate measurement of the
bias current becomes difficult. Not only does this measurement require a picoammeter, but test socket leakages
can easily exceed the actual device bias currents. To measure these small currents, Texas Instruments uses
a two-step process. The socket leakage is measured using picoammeters with bias voltages applied but with
no device in the socket. The device is then inserted in the socket, and a second test measuring both the socket
leakage and the device input bias current is performed. The two measurements are then subtracted
algebraically to determine the bias current of the device.
noise
Texas Instruments offers automated production noise testing to meet individual application requirements. Noise
voltage at f = 10 Hz and f = 1 kHz is 100% tested on every TLC2201B device, while lot sample testing is
performed on the TLC220xA. For other noise requirements, please contact the factory.
42
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
Table of Graphs
FIGURE
VIO
Input offset voltage
Distribution
IIB
Input bias current
vs Common-mode input voltage
vs Free-air temperature
7
8
VOM
Maximum peak output voltage
vs Output current
vs Free-air temperature
9
10
VO(PP)
Maximum peak-to-peak output voltage
vs Frequency
11
VOH
High-level output voltage
vs Frequency
vs High-level output current
vs Free-air temperature
12
13
14
VOL
Low-level output voltage
vs Low-level output current
vs Free-air temperature
15
16
AVD
Large-signal differential voltage amplification
vs Frequency
vs Free-air temperature
17
18
IOS
Short-circuit output current
vs Supply voltage
vs Free-air temperature
19
20
CMRR
Common-mode rejection ratio
vs Frequency
21
IDD
Supply current
vs Supply voltage
vs Free-air temperature
22
23, 24
Pulse response
Small signal
Large signal
25, 26
27, 28
Slew rate
vs Supply voltage
vs Free-air temperature
29
30
Noise voltage (referred to input)
0.1 to 1 Hz
0.1 to 10 Hz
31
32
Gain-bandwidth product
vs Supply voltage
vs Free-air temperature
33, 34
35
Phase margin
vs Supply voltage
vs Free-air temperature
36, 37
38, 39
Phase shift
vs Frequency
SR
φm
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5, 6
17
43
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
TLC2202
DISTRIBUTION OF
INPUT OFFSET VOLTAGE
DISTRIBUTION OF TLC2201
INPUT OFFSET VOLTAGE
16
20
1726 Amplifiers Tested From 1 Wafer Lot
VDD ± = ± 15 V
TA = 25°C
P Package
14
Percentage of Units − %
Percentage of Units − %
16
408 Units Tested From 2 Wafer Lots
VDD ± = ± 5 V
TA = 25°C
P Package
12
8
12
10
8
6
4
4
2
0
−500
−300
100
−100
300
0
−1000
500
−600
−200
VIO − Input Offset Voltage − µV
300
VDD ± = ± 5 V
TA = 25°C
VDD ± = ± 5 V
VO = 0
VIC = 0
250
6
I IB − Input Bias Current − pA
IIIB
IB − Input Bias Current − pA
1000
INPUT BIAS CURRENT†
vs
FREE-AIR TEMPERATURE
INPUT BIAS CURRENT
vs
COMMON-MODE INPUT VOLTAGE
8
600
Figure 6
Figure 5
10
200
VIO − Input Offset Voltage − µV
4
2
0
−2
−4
−6
200
150
100
50
−8
−10
−5
0
−4
−3
−2
−1
0
1
2
3
4
5
25
45
65
85
105
TA − Free-Air Temperature − °C
VIC − Common-Mode Input Voltage − V
Figure 7
Figure 8
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
44
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
125
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
MAXIMUM PEAK OUTPUT VOLTAGE†
vs
FREE-AIR TEMPERATURE
MAXIMUM PEAK OUTPUT VOLTAGE
vs
OUTPUT CURRENT
6
VDD ± = ± 5 V
TA = 25°C
VOM +
VOM
V OM − Maximum Peak Output Voltage − V
|VOM| − Maximum Peak Output Voltage − V
VOM
5
4
VOM −
3
2
1
0
0
2
4
8
6
VOM +
4
2
VDD ± = ± 5 V
RL = 10 kΩ
0
−2
−4
VOM −
−6
−75
10
−50
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
|IO| − Output Current − mA
Figure 9
Figure 10
MAXIMUM PEAK-TO-PEAK OUTPUT VOLTAGE†
vs
FREQUENCY
HIGH-LEVEL OUTPUT VOLTAGE†
vs
FREQUENCY
5
10
VOH − High-Level Output Voltage − V
V0H
VO(PP) − Maximum Peak-to-Peak Output Voltage − V
125
8
TA = − 55°C
6
TA = 125°C
4
2
VDD ± = ± 5 V
RL = 10 kΩ
0
10 k
30 k
100 k
300 k
1M
4
TA = − 55°C
3
TA = 125°C
2
1
VDD = 5 V
RL = 10 kΩ
0
10 k
f − Frequency − Hz
30 k
100 k
300 k
1M
f − Frequency − Hz
Figure 11
Figure 12
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
45
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
HIGH-LEVEL OUTPUT VOLTAGE†
vs
FREE-AIR TEMPERATURE
HIGH-LEVEL OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT CURRENT
VDD
6
VDD = 5 V
RL = 10 kΩ
VDD − 2
V OH − High-Level Output Voltage − V
VOM
V OH − High-Level Output Voltage − V
VOM
TA = 25°C
VDD = 5 V
VDD − 4
VDD − 6
VDD = 10 V
VDD − 8
VDD − 10
VDD − 12
VDD = 16 V
VDD − 14
VDD − 16
0
1
2
3
4
5
4
3
2
1
0
−75
5
−50
IOH − High-Level Output Current − mA
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
Figure 13
Figure 14
LOW-LEVEL OUTPUT VOLTAGE†
vs
FREE-AIR TEMPERATURE
LOW-LEVEL OUTPUT VOLTAGE
vs
LOW-LEVEL OUTPUT CURRENT
1.5
2
VDD = 5 V
VDD = 5 V
VDD = 10 V
VOL
VOL − Low-Level Output Voltage − V
TA = 25°C
VOL
VOL − Low-Level Output Voltage − V
125
VDD = 16 V
1.5
1
0.5
IOL = 5 mA
1
0.5
IOL = 1 mA
0
0
2
4
6
8
IOL − Low-Level Output Current − mA
10
0
−75
−50
Figure 15
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
Figure 16
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
46
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
125
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
LARGE-SIGNAL DIFFERENTIAL VOLTAGE
AMPLIFICATION†
vs
FREE-AIR TEMPERATURE
LARGE-SIGNAL DIFFERENTIAL VOLTAGE
AMPLIFICATION AND PHASE SHIFT
vs
FREQUENCY
50°
80
70°
60
90°
Phase Shift
40
110°
20
130°
150°
0
−20
10
100
1k
10 k
100 k
AVD
A
VD − Large-Signal Differential
Voltage Amplification − dB
AVD
Phase Shift
AVD
AVD − Large-Signal Differential
Voltage Amplification − dB
VDD ± = ± 5 V
RL = 10 kΩ
CL = 100 pF
TA = 25°C
100
ÁÁ
ÁÁ
130
30°
120
ÁÁ
ÁÁ
ÁÁ
VDD ± = ± 5 V, RL = 500 kΩ
120
110
VDD = 5 V, RL = 500 kΩ
VDD ± = ± 5 V, RL = 10 kΩ
100
VDD = 5 V, RL = 10 kΩ
90
80
−75
170°
1M
−50
f − Frequency − Hz
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
Figure 18
Figure 17
SHORT-CIRCUIT OUTPUT CURRENT†
vs
FREE-AIR TEMPERATURE
SHORT-CIRCUIT OUTPUT CURRENT
vs
SUPPLY VOLTAGE
12
15
VO = 0
TA= 25°C
8
IIOS
OS − Short-Circuit Output Current − mA
IIOS
OS − Short-Circuit Output Current − mA
125
4
VID = − 100 mV
0
−4
−8
VID = 100 mV
−12
0
1
2
3
4
5
6
|VDD ±| − Supply Voltage − V
7
8
VDD ± = ± 5 V
VO = 0
10
5
VID = − 100 mV
0
−5
VID = 100 mV
−10
−15
−75
−50
Figure 19
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
125
Figure 20
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
47
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
SUPPLY CURRENT†
vs
SUPPLY VOLTAGE
COMMON-MODE REJECTION RATIO
vs
FREQUENCY
2.5
VO = 0
No Load
TA = 25°C
100
2
IDD
I DD − Supply Current − mA
CMRR − Common-Mode Rejection Ratio − dB
120
VDD ± = ± 5 V
80
60
VDD = 5 V
40
1.5
1
0.5
20
0
0
10
100
1k
100 k
10 k
1M
0
1
f − Frequency − Hz
2
3
4
5
6
7
8
|VDD ±| − Supply Voltage − V
Figure 21
Figure 22
TLC2201
SUPPLY CURRENT†
vs
FREE-AIR TEMPERATURE
TLC2202
SUPPLY CURRENT†
vs
FREE-AIR TEMPERATURE
1.2
2.5
VDD ± = ± 5 V
VO = VDD + /2
No Load
1
2
IIDD
DD − Supply Current − mA
IIDD
DD − Supply Current − mA
TA = 125°C
TA = 25°C
TA = − 55°C
VDD = 5 V
0.8
0.6
0.4
VDD ± = ± 5 V
VDD = 5 V
1.5
1
0.5
0.2
VO = VDD + / 2
No Load
0
−75
−50
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
125
0
−75
−50
Figure 23
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
Figure 24
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
48
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
125
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
VOLTAGE-FOLLOWER
SMALL-SIGNAL
PULSE RESPONSE
VOLTAGE-FOLLOWER
SMALL-SIGNAL
PULSE RESPONSE
VO − Output Voltage − mV
VO
75
50
160
VDD ± = ± 5 V
RL = 10 kΩ
CL = 100 pF
TA = 25°C
140
120
VO − Output Voltage − mV
VO
100
25
0
−25
−50
−75
VDD = 5 V
RL = 10 kΩ
CL = 100 pF
TA = 25°C
100
80
60
40
20
0
−20
−100
0
1
2
3
4
5
6
7
0
t − Time − µs
Figure 25
1
2
3
4
t − Time − µs
5
VDD = 5 V
RL = 10 kΩ
CL = 100 pF
TA = 25°C
4
4
VO − Output Voltage − V
VO
VO − Output Voltage − V
VO
3
2
1
0
−1
−2
−5
7
VOLTAGE-FOLLOWER
LARGE-SIGNAL
PULSE RESPONSE
5
VDD ± = ± 5 V
RL = 10 kΩ
CL = 100 pF
TA = 25°C
−4
6
Figure 26
VOLTAGE-FOLLOWER
LARGE-SIGNAL
PULSE RESPONSE
−3
5
3
2
1
0
−1
0
5
10
15
20
25
30
35
40
0
t − Time − µs
5
10
15
20
25
30
35
40
t − Time − µs
Figure 27
Figure 28
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
49
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
SLEW RATE†
vs
FREE-AIR TEMPERATURE
SLEW RATE
vs
SUPPLY VOLTAGE
4
4
SR −
RL = 10 kΩ
CL = 100 pF
TA = 25°C
SR −
3
SR − Slew Rate − V/µ s
SR − Slew Rate − V/µ s
3
SR +
2
SR +
2
1
1
0
−75
0
0
1
2
3
4
5
6
7
8
VDD ± = ± 5 V
RL = 10 kΩ
CL = 100 pF
−50
|VDD ±| − Supply Voltage − V
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
Figure 29
Figure 30
NOISE VOLTAGE
(REFERRED TO INPUT)
OVER A 10-SECOND INTERVAL
NOISE VOLTAGE
(REFERRED TO INPUT)
OVER A 10-SECOND INTERVAL
1
1
VDD ± = ± 5 V
f = 0.1 Hz to 1 Hz
TA= 25°C
0.75
125
VDD ± = ± 5 V
f = 0.1 Hz to 10 Hz
TA= 25°C
0.8
0.6
0.4
V
Noise Voltage − µ
uV
V
Noise Voltage − µ
uV
0.5
0.25
0
−0.25
0.2
0
−0.2
−0.4
−0.5
−0.6
−0.75
−1
0
−0.8
1
2
3
4
5
6
7
8
9
10
−1
0
1
t − Time − s
2
3
4
5
6
7
8
9
t − Time − s
Figure 31
Figure 32
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
50
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
10
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
TLC2201
GAIN-BANDWIDTH PRODUCT
vs
SUPPLY VOLTAGE
TLC2202
GAIN-BANDWIDTH PRODUCT
vs
SUPPLY VOLTAGE
2.1
RL = 10 kΩ
CL = 100 pF
TA = 25°C
Gain-Bandwidth Product − MHz
Gain-Bandwidth Product − MHz
2.1
2
1.9
1.8
0
1
6
2
3
4
5
|VDD ±| − Supply Voltage − V
7
f = 10 kHz
RL = 10 kΩ
CL = 100 pF
TA = 25°C
2
1.9
1.8
8
0
1
6
2
3
4
5
|VDD ±| − Supply Voltage − V
8
Figure 34
Figure 33
TLC2201
PHASE MARGIN
vs
SUPPLY VOLTAGE
GAIN-BANDWIDTH PRODUCT†
vs
FREE-AIR TEMPERATURE
2.5
50°
f = 10 kHz
RL = 10 kΩ
CL = 100 pF
RL = 10 kΩ
CL = 100 pF
TA = 25°C
48°
VDD ± = ± 5 V
2
φm − Phase Margin
om
Gain-Bandwidth Product − MHz
7
VDD = 5 V
1.5
46°
44°
42°
1
−75
40°
−50
−25
0
25
50
75 100
TA − Free-Air Temperature − °C
125
0
1
2
3
4
5
6
|VDD ±| − Supply Voltage − V
7
8
Figure 36
Figure 35
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
51
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
TYPICAL CHARACTERISTICS
TLC2202
PHASE MARGIN
vs
SUPPLY VOLTAGE
50°
TLC2201
PHASE MARGIN†
vs
FREE-AIR TEMPERATURE
50°
RL = 10 kΩ
CL = 100 pF
TA = 25°C
VDD ± = ± 5 V
48°
φm − Phase Margin
om
φ
om
m − Phase Margin
48°
46°
44°
42°
46°
VDD = 5 V
44°
42°
RL = 10 kΩ
CL = 100 pF
40°
0
1
2
3
4
5
6
|VDD ±| − Supply Voltage − V
7
40°
−75
8
−50
−25
0
25
50
75
100
125
TA − Free-Air Temperature − °C
Figure 37
Figure 38
TLC2202
PHASE MARGIN†
vs
FREE-AIR TEMPERATURE
50°
VDD ± = ± 5 V
φ
om
m − Phase Margin
48°
VDD = 5 V
46°
44°
42°
RL = 10 kΩ
CL = 100 pF
40°
−75
−50
−25
0
25
50
75
100
125
TA − Free-Air Temperature − °C
Figure 39
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
52
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
APPLICATION INFORMATION
latch-up avoidance
Because CMOS devices are susceptible to latch-up due to their inherent parasitic thyristors, the TLC220x,
TLC220xA, and TLC220xB inputs and outputs are designed to withstand − 100-mA surge currents without
sustaining latch-up; however, techniques reducing the chance of latch-up should be used whenever possible.
Internal protection diodes should not be forward biased in normal operation. Applied input and output voltages
should not exceed the supply voltage by more than 300 mV. Care should be exercised when using capacitive
coupling on pulse generators. Supply transients should be shunted by the use of decoupling capacitors
(0.1 µF typical) located across the supply rails as close to the device as possible.
electrostatic discharge protection
These devices use internal ESD-protection circuits that prevent functional failures at voltages at or below
2000 V. Care should be exercised in handling these devices as exposure to ESD may result in degradation of
the device parametric performance.
macromodel information
Macromodel information provided was derived using Microsim Parts, the model generation software used
with Microsim PSpice. The Boyle macromodel (see Note 5) and subcircuit in Figure 40 were generated using
the TLC220x typical electrical and operating characteristics at 25°C. Using this information, output simulations
of the following key parameters can be generated to a tolerance of 20% (in most cases):
D Maximum positive output voltage swing
D Unity-gain frequency
D Maximum negative output voltage swing
D Common-mode rejection ratio
D Slew rate
D Phase margin
D Quiescent power dissipation
D DC output resistance
D Input bias current
D AC output resistance
D Open-loop voltage amplification
D Short-circuit output current limit
NOTE 5: G. R. Boyle, B. M. Cohn, D. O. Pederson, and J. E. Solomon, “Macromodeling of Integrated Circuit Operational Amplifiers”, IEEE Journal
of Solid-State Circuits, SC-9, 353 (1974).
PSpice and Parts are trademarks of MicroSim Corporation.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
53
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
APPLICATION INFORMATION
macromodel information (continued)
99
3
VCC +
egnd
9
rss
92
fb
−
+
iss
din
+
rp
2
10
IN −
j1
dp
vc
j2
IN+
1
11
r2
−
53
C2
6
dc
12
hlim
−
+
VCC −
54
4
+
−
−
+
vin
+
gcm
ga
−
ro1
de
5
−
ve
OUT
.subckt TLC220x 1 2 3 4 5
*
c1
11 12 8.51E−12
c2
6
7 50.00E−12
cpsr 85 86 79.6E−9
dcm+ 81 82 dx
dcm− 83 81 dx
dc
5
53 dx
de
54 5 dx
dlp 90 91 dx
dln 92 90 dx
dp
4
3 dx
ecmr 84 99 (2,99) 1
egnd 99 0 poly(2) (3,0) (4,0) 0 .5 .5
epsr 85 0 poly(1) (3,4) −200E−6 20E−6
ense 89 2 poly(1) (88,0) 100E−6 1
fb
7
99 poly(6) vb vc ve vlp vln
+ vpsr 0 +
895.9E3 −90E3 90E3 90E3 −90E3 895E3
ga
6
0 11 12 314.2E−6
gcm 0
6 10 99 1.295E−9
gpsr 85 86 (85,86) 100E−6
grd1 60 11 (60,11) 3.141E−4
grd2 60 12 (60,12) 3.141E−4
hlim 90 0 vlim 1k
hcmr 80 1 poly(2) vcm+ vcm− 0 1E2 1E2
irp 3
4 965E−6
iss 3
10 dc 135.0E−6
iio 2
0 .5E−12
i1
88 0 1E−21
j1
11 89 10 jx
j2
12 80 10 jx
r2
6
9 100.0E3
rcm 84 81 1k
rn1 88 0 1500
ro1 8
5 188
ro2 7
99 187
rss 10 99 1.481E6
vad 60 4 −.3v
vcm+ 82 99 2.2
vcm− 83 99 −4.5
vb
9
0 dc 0
vc
3
53 dc .9
ve
54 4 dc .8
vlim 7
8 dc 0
vlp 91 0 dc 2.8
vln 0
92 dc 2.8
vpsr 0
86 dc 0
.model dx d(is=800.0E−18)
.model jx pjf(is=500.0E−15 beta=1.462E−3
+ vto=−.155 kf=1E−17)
.endsx
Figure 40. Boyle Macromodel and Subcircuit
54
−
vlim
8
rd2
91
+
vip
7
C1
rd1
+ dip
90
ro2
vb
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
14-Aug-2021
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
5962-9088201M2A
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088201M2A
TLC2201MFKB
5962-9088201MPA
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088201MPA
TLC2201M
5962-9088202M2A
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088202M2A
TLC2202MFKB
5962-9088202MPA
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088202MPA
TLC2202M
5962-9088203QPA
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088203QPA
TLC2201AM
5962-9088204Q2A
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088204Q2A
TLC2202
AMFKB
5962-9088204QPA
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088204QPA
TLC2202AM
TLC2201ACD
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201AC
TLC2201ACDR
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201AC
TLC2201ACDRG4
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201AC
TLC2201AID
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2201AI
TLC2201AIDG4
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2201AI
TLC2201AIDR
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2201AI
TLC2201AMD
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC2201AMDG4
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC2201AMJG
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
Addendum-Page 1
-55 to 125
2201AM
2201AM
-55 to 125
TLC2201
AMJG
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
14-Aug-2021
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
TLC2201AMJGB
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
TLC2201CD
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201C
TLC2201CDG4
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201C
TLC2201CDR
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201C
TLC2201CDRG4
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2201C
TLC2201CP
ACTIVE
PDIP
P
8
50
RoHS & Green
NIPDAU
N / A for Pkg Type
0 to 70
TLC2201CP
TLC2201ID
ACTIVE
SOIC
D
8
75
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2201I
TLC2201IDR
ACTIVE
SOIC
D
8
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2201I
TLC2201IP
ACTIVE
PDIP
P
8
50
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC2201MFKB
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088201M2A
TLC2201MFKB
TLC2201MJGB
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088201MPA
TLC2201M
TLC2202ACD
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
TLC2202ACDR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2202AC
TLC2202ACDRG4
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
2202AC
TLC2202AID
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
2202AI
TLC2202AIDG4
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
2202AI
TLC2202AMFKB
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088204Q2A
TLC2202
AMFKB
TLC2202AMJG
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
TLC2202
AMJG
Addendum-Page 2
9088203QPA
TLC2201AM
TLC2201IP
2202AC
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
14-Aug-2021
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
TLC2202AMJGB
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088204QPA
TLC2202AM
TLC2202CD
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2202C
TLC2202CDR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
2202C
TLC2202CP
ACTIVE
PDIP
P
8
50
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC2202CPS
ACTIVE
SO
PS
8
80
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
P2202
TLC2202CPSR
ACTIVE
SO
PS
8
2000
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
P2202
TLC2202ID
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC2202I
TLC2202IDG4
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC2202I
TLC2202IP
ACTIVE
PDIP
P
8
50
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC2202IP
TLC2202IPE4
ACTIVE
PDIP
P
8
50
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC2202IP
TLC2202MFKB
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
59629088202M2A
TLC2202MFKB
TLC2202MJG
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
TLC2202MJG
TLC2202MJGB
ACTIVE
CDIP
JG
8
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
9088202MPA
TLC2202M
TLC2202CP
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Addendum-Page 3
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
14-Aug-2021
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of