0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TLC2558IPWR

TLC2558IPWR

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP20

  • 描述:

    IC ADC 12BIT SAR 20TSSOP

  • 数据手册
  • 价格&库存
TLC2558IPWR 数据手册
TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 D D D D D D D Maximum Throughput 400 KSPS Built-In Reference and 8× FIFO Differential/Integral Nonlinearity Error: ±1 LSB Signal-to-Noise and Distortion Ratio: 69 dB, fi = 12 kHz Spurious Free Dynamic Range: 75 dB, fi = 12 kHz SPI/DSP-Compatible Serial Interfaces With SCLK up to 20 MHz Single Supply 5 Vdc D D D D D Analog Input Range 0 V to Supply Voltage With 500 kHz BW Hardware Controlled and Programmable Sampling Period Low Operating Current (4 mA at 5.5 V External Ref, 6 mA at 5.5 V, Internal Ref) Power Down: Software/Hardware Power-Down Mode (1 µA Max, Ext Ref), Auto Power-Down Mode (1 µA, Ext Ref) Programmable Auto-Channel Sweep D OR PW PACKAGE DW OR PW PACKAGE (TOP VIEW) (TOP VIEW) SDO SDI SCLK EOC/(INT) VCC A0 A1 A2 A3 A4 1 20 2 19 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 CS REFP REFM FS PWDN GND CSTART A7 A6 A5 SDO SDI SCLK EOC/(INT) VCC A0 A1 A2 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 CS REFP REFM FS PWDN GND CSTART A3 description The TLC2558 and TLC2554 are a family of high-performance, 12-bit low power, 1.6 µs, CMOS analog-to-digital converters (ADC) which operate from a single 5 V power supply. These devices have three digital inputs and a 3-state output [chip select (CS), serial input-output clock (SCLK), serial data input (SDI), and serial data output (SDO)] that provide a direct 4-wire interface to the serial port of most popular host microprocessors (SPI interface). When interfaced with a DSP, a frame sync (FS) signal is used to indicate the start of a serial data frame. In addition to a high-speed A/D converter and versatile control capability, these devices have an on-chip analog multiplexer that can select any analog inputs or one of three internal self-test voltages. The sample-and-hold function is automatically started after the fourth SCLK edge (normal sampling) or can be controlled by a special pin, CSTART, to extend the sampling period (extended sampling). The normal sampling period can also be programmed as short (12 SCLKs) or as long (24 SCLKs) to accommodate faster SCLK operation popular among high-performance signal processors. The TLC2558 and TLC2554 are designed to operate with very low power consumption. The power-saving feature is further enhanced with software/hardware/auto power down modes and programmable conversion speeds. The converter uses the external SCLK as the source of the conversion clock to achieve higher (up to 1.6 µs when a 20 MHz SCLK is used) conversion speed. There is a 4-V internal reference available. An optional external reference can also be used to achieve maximum flexibility. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright  1999, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 functional block diagram VCC 4V Reference REFP REFM 2554 A0 X A1 X A2 X A3 X Analog MUX 2558 A0 A1 A2 A3 A4 A5 A6 A7 FIFO 12 Bit × 8 Low Power 12-BIT SAR ADC S/H Conversion Clock Command Decode CFR SDI M U X SDO CMR (4 MSBs) SCLK CS FS CSTART PWDN Control Logic EOC/(INT) GND AVAILABLE OPTIONS PACKAGED DEVICES TA 2 20-TSSOP (PW) 20-SOIC (DW) 16-SOIC (D) 16-TSSOP (PW) 0°C to 70°C TLC2558CPW TLC2558CDW TLC2554CD TLC2554CPW – 40°C to 85°C TLC2558IPW TLC2558IDW TLC2554ID TLC2554IPW POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 Terminal Functions TERMINAL NAME A0 A1 A2 A3 A0 A1 A2 A3 A4 A5 A6 A7 CS NO. I/O DESCRIPTION 6 7 8 9 10 11 12 13 I Analog signal inputs. The analog inputs are applied to these terminals and are internally multiplexed. The driving source impedance should be less than or equal to 1 kΩ. 20 I TLC2554 TLC2558 6 7 8 9 16 For a source impedance greater than 1 kΩ, use the asynchronous conversion start signal CSTART (CSTART low time controls the sampling period) or program long sampling period to increase the sampling time. Chip select. A high-to-low transition on the CS input resets the internal 4-bit counter, enables SDI, and removes SDO from 3-state within a maximum setup time. SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first. SDO is 3-stated after the rising edge of CS. CS can be used as the FS pin when a dedicated serial port is used. CSTART 10 14 I EOC/(INT) 4 4 O This terminal controls the start of sampling of the analog input from a selected multiplex channel. A high-to-low transition starts sampling of the analog input signal. A low-to-high transition puts the S/H in hold mode and starts the conversion. This input is independent from SCLK and works when CS is high (inactive). The low time of CSTART controls the duration of the sampling period of the converter (extended sampling). Tie this terminal to VCC if not used. End of conversion or interrupt to host processor. [PROGRAMMED AS EOC]: This output goes from a high-to-low logic level at the end of the sampling period and remains low until the conversion is complete and data are ready for transfer. EOC is used in conversion mode 00 only. [PROGRAMMED AS INT]: This pin can also be programmed as an interrupt output signal to the host processor. The falling edge of INT indicates data are ready for output. The following CS↓ or FS↑ clears INT. The falling edge of INT puts SDO back to 3-state even if CS is still active. FS 13 17 I DSP frame sync input. Indication of the start of a serial data frame in or out of the device. If FS remains low at the falling edge of CS, SDI is not enabled. A high-to-low transition on the FS input resets the internal 4-bit counter and enables SDI within a maximum setup time. SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first. SDO is 3-stated after the 16th bit is presented. GND 11 15 I Ground return for the internal circuitry. Unless otherwise noted, all voltage measurements are with respect to GND. PWDN 12 16 I Both analog and reference circuits are powered down when this pin is at logic zero. The device can be restarted by active CS or CSTART after this pin is pulled back to logic one. SCLK 3 3 I Input serial clock. This terminal receives the serial SCLK from the host processor. SCLK is used to clock the input SDI to the input register. It is also used as the source of the conversion clock. SDI 2 2 I Serial data input. The input data is presented with the MSB (D15) first. The first 4-bit MSBs, D(15–12) are decoded as one of the 16 commands (12 only for the TLC2554). All trailing blanks are filled with zeros. The configure write commands require an additional 12 bits of data. When FS is not used (FS =1), the first MSB (D15) is expected after the falling edge of CS and is shifted in on the rising edges of SCLK (after CS↓). When FS is used (typical with an active FS from a DSP) the first MSB (D15) is expected after the falling edge of FS and is shifted in on the falling edges of SCLK. Tie this terminal to VCC if not used. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 Terminal Functions (Continued) TERMINAL NAME SDO NO. TLC2554 TLC2558 1 1 I/O DESCRIPTION O The 3-state serial output for the A/D conversion result. SDO is kept in the high-impedance state when CS is high and after the CS falling edge and until the MSB (D15) is presented. The output format is MSB (D15) first. When FS is not used (FS = 1 at the falling edge of CS), the MSB (D15) is presented to the SDO pin after the CS falling edge, and successive data are available at the rising edge of SCLK. When FS is used (FS = 0 at the falling edge of CS), the MSB (D15) is presented to SDO after the falling edge of CS and FS = 0 is detected. Successive data are available at the falling edge of SCLK. (This is typically used with an active FS from a DSP.) For conversion and FIFO read cycles, the first 12 bits are the result from the previous conversion (data) followed by 4 trailing zeros. The first four bits from SDO for CFR read cycles should be ignored. The register content is in the last 12 bits. SDO is 3 stated after the 16th bit. REFM 14 18 I External reference input or internal reference decoupling. REFP 15 19 I External reference input or internal reference decoupling. (Shunt capacitors of 10 µF and 0.1 µF between REFP and REFM.) The maximum input voltage range is determined by the difference between the voltage applied to this terminal and the REFM terminal when an external reference is used. VCC 5 5 I Positive supply voltage detailed description analog inputs and internal test voltages The 4/8 analog inputs and three internal test inputs are selected by the analog multiplexer depending on the command entered. The input multiplexer is a break-before-make type to reduce input-to-input noise injection resulting from channel switching. pseudo-differential/single-ended input All analog inputs can be programmed as single-ended or pseudo-differential mode. Pseudo-differential mode is enabled by setting CFR.D7 – 1. Only three analog input channels (or seven channels for TLC2558) are available for TLV2554 since one input (A1 for TLC2554 or A2 for TLC2558) is used as the MINUS input when pseudo-differential mode is used. The minus input pin can have a maximum ±0.2 V ripple. This is normally used for ground noise rejection. converter The TLC2554/58 uses a 12-bit successive approximation ADC and 2-bit resistor string. The CMOS threshold detector in the successive-approximation conversion system determines each bit by examining the charge on a series of binary-weighted capacitors (see Figure 1). In the first phase of the conversion process, the analog input is sampled by closing the SC switch and all ST switches simultaneously. This action charges all the capacitors to the input voltage. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 converter (continued) SC Threshold Detector To Output Latch 512 256 8 REF+ REF+ 4 2 1 1 Node 512 REF– REF– ST REF– ST REF+ REF+ REF– REF– ST ST REF+ 2-Bit R-String DAC REF+ REF– ST ST ST VI Figure 1. Simplified Model of the Successive-Approximation System In the next phase of the conversion process the threshold detector begins identifying bits by identifying the charge (voltage) on each capacitor relative to the reference (REFM) voltage. In the switching sequence, ten capacitors are examined separately until all ten bits are identified and the charge-convert sequence is repeated. In the first step of the conversion phase, the threshold detector looks at the first capacitor (weight = 512). Node 512 of this capacitor is switched to the REFP voltage, and the equivalent nodes of all the other capacitors on the ladder are switched to REFM. If the voltage at the summing node is greater than the trip point of the threshold detector (approximately one-half the VCC voltage), a bit 0 is placed in the output register and the 512-weight capacitor is switched to REFM. If the voltage at the summing node is less than the trip point of the threshold detector, a bit 1 is placed in the register. The 512-weight capacitor remains connected to REFP through the remainder of the successive-approximation process. The process is repeated for the 1024-weight capacitor, the 128-weight capacitor, and so forth down the line until all bits are counted. With each step of the successive-approximation process, the initial charge is redistributed among the capacitors. The conversion process relies on charge redistribution to count and weigh the bits from MSB to LSB. serial interface INPUT DATA FORMAT MSB LSB D15–D12 D11–D0 Command Configuration data field Input data is binary. All trailing blanks can be filled with zeros. OUTPUT DATA FORMAT READ CFR MSB LSB D15–D12 D11–D0 Don’t care Register content OUTPUT DATA FORMAT CONVERSION/READ FIFO MSB LSB D15–D4 Conversion result POST OFFICE BOX 655303 D3–D0 All zeros • DALLAS, TEXAS 75265 5 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 serial interface (continued) The output data format is either binary (unipolar straight binary) or 2s complement. binary Zero scale code = 000h, Vcode = VREFM Full scale code = FFFh, Vcode = VREFP – 1 LSB 2’s complement Minus full scale code = 800h, Vcode = VREFM Full scale code = 7FFh, Vcode = VREFP – 1 LSB control and timing start of the cycle: D D When FS is not used ( FS = 1 at the falling edge of CS), the falling edge of CS is the start of the cycle. Input data is shifted in on the rising edge, and output data changes on the falling edge of SCLK. This is typically used for a SPI microcontroller, although it can also be used for a DSP. When FS is used ( FS is an active signal from a DSP), the falling edge of FS is the start of the cycle. Input data is shifted in on the falling edge, and output data changes on the rising edge of SCLK. This is typically used for a TMS320 DSP. first 4-MSBs: the command register (CMR) The TLC2554/TLC2558 have a 4-bit command set (see Table 1) plus a 12-bit configuration data field. Most of the commands require only the first 4 MSBs, i.e. without the 12-bit data field. NOTE: The device requires a write CFR (configuration register) with 000h data (write A000h to the serial input) at power up to initialize host select mode. The valid commands are listed in Table 1. Table 1. TLC2554/TLC2558 Command Set SDI D(15–12) BINARY, HEX 6 TLC2558 COMMAND TLC2554 COMMAND 0000b 0000h Select analog input channel 0 Select analog input channel 0 0001b 1000h Select analog input channel 1 N/A 0010b 2000h Select analog input channel 2 Select analog input channel 1 0011b 3000h Select analog input channel 3 N/A 0100b 4000h Select analog input channel 4 Select analog input channel 2 0101b 5000h Select analog input channel 5 N/A 0110b 6000h Select analog input channel 6 Select analog input channel 3 0111b 7000h Select analog input channel 7 N/A 1000b 8000h SW power down (analog + reference) 1001b 9000h Read CFR register data shown as SDO D(11–0) 1010b A000h plus data Write CFR followed by 12-bit data 1011b B000h Select test, voltage = (REFP+REFM)/2 1100b C000h Select test, voltage = REFM 1101b D000h Select test, voltage = REFP 1110b E000h FIFO read, FIFO contents shown as SDO D(15–4), D(3–0) = 0000 1111b F000h plus data Reserved POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 control and timing (continued) configuration Configuration data is stored in one 12-bit configuration register (CFR) (see Table 2 for CFR bit definitions). Once configured after first power up, the information is retained in the H/W or S/W power-down state. When the device is being configured, a write CFR cycle is issued by the host processor. This is a 16-bit write. If the SCLK stops after the first 8 bits are entered, then the next eight bits can be taken after the SCLK is resumed. The status of the CFR can be read with a read CFR command. Table 2. TLC2554/TLC2558 Configuration Register (CFR) Bit Definitions BIT DEFINITION D(15–12) All zeros, nonprogrammable D11 Reference select 0: External 1: Internal D10 Output select 0: Unipolar straight binary 1: 2’s complement D9 Sample period select 0: Short sampling 12 SCLKs (1x sampling time) 1: Long sampling 24 SCLKs (2x sampling time) D8 Conversion clock source select 0: Conversion clock = SCLK 1: Conversion clock = SCLK/2 D7 Input select 0: Normal 1: Pseudo differential CH A2(2558) or CH A1 (2554) is the differential input D(6,5) Conversion mode select 00: Single shot mode 01: Repeat mode 10: Sweep mode 11: Repeat sweep mode D(4,3)† TLC2558 Sweep auto sequence select 00: 0–1–2–3–4–5–6–7 01: 0–2–4–6–0–2–4–6 10: 0–0–2–2–4–4–6–6 11: 0–2–0–2–0–2–0–2 TLC2554 Sweep auto sequence select 00: N/A 01: 0–1–2–3–0–1–2–3 10: 0–0–1–1–2–2–3–3 11: 0–1–0–1–0–1–0–1 D2 EOC/INT – pin function select 0: Pin used as INT 1: Pin used as EOC D(1,0) FIFO trigger level (sweep sequence length) 00: Full (INT generated after FIFO level 7 filled) 01: 3/4 (INT generated after FIFO level 5 filled) 10: 1/2 (INT generated after FIFO level 3 filled) 11: 1/4 (INT generated after FIFO level 1 filled) † These bits only take effect in conversion modes 10 and 11. sampling The sampling period starts after the first 4 input data are shifted in if they are decoded as one of the conversion commands. These are select analog input (channel 0 through 7) and select test (channel 1 through 3). POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 normal sampling When the converter is using normal sampling, the sampling period is programmable. It can be 12 SCLKs (short sampling) or 24 SCLKs (long sampling). Long sampling helps the input analog signal sampled to settle to 0.5 LSB accuracy when input source resistance is high. extended sampling An asynchronous (to the SCLK) signal, via dedicated hardware pin CSTART, can be used in order to have total control of the sampling period and the start of a conversion. This is extended sampling. The falling edge of CSTART is the start of the sampling period. The rising edge of CSTART is the end of the sampling period and the start of the conversion. This function is useful for an application that requires: D D The use of an extended sampling period to accommodate different input source impedance. The use of a faster I/O clock on the serial port but not enough sampling time is available due to the fixed number of SCLKs. This could be due to a high input source impedance or due to higher MUX ON resistance at lower supply voltage (refer to application information). Once the conversion is complete, the processor can initiate a read cycle using either the read FIFO command to read the conversion result or simply select the next channel number for conversion. Since the device has a valid conversion result in the output buffer, the conversion result is simply presented at the serial data output. TLC2554/TLC2558 conversion modes The TLC2554 and TLC2558 have four different conversion modes (mode 00, 01, 10, 11). The operation of each mode is slightly different, depending on how the converter performs the sampling and which host interface is used. The trigger for a conversion can be an active CSTART (extended sampling), CS (normal sampling, SPI interface), or FS (normal sampling, TMS320 DSP interface). When FS is used as the trigger, CS can be held active, i.e. CS does not need to be toggled through the trigger sequence. Different types of triggers should not be mixed throughout the repeat and sweep operations. When CSTART is used as the trigger, the conversion starts on the rising edge of CSTART. The minimum low time for CSTART is 800 ns. If an active CS or FS is used as the trigger, the conversion is started after the 16th or 28th SCLK edge. Enough time (for conversion) should be allowed between consecutive triggers so that no conversion is terminated prematurely. one shot mode (mode 00) One shot mode (mode 00) does not use the FIFO, and the EOC is generated as the conversion is in progress (or INT is generated after the conversion is done). repeat mode (mode 01) Repeat mode (mode 01) uses the FIFO. Once the programmed FIFO threshold is reached, the FIFO must be read, or the data is lost and the sequence starts over again. This allows the host to set up the converter and continue monitoring a fixed input and come back to get a set of samples when preferred. The first conversion must start with a select command so an analog input channel can be selected. sweep mode (mode 10) Sweep mode (mode 10) also uses the FIFO. Once it is programmed in this mode, all of the channels listed in the selected sweep sequence are visited in sequence. The results are converted and stored in the FIFO. This sweep sequence may not be completed if the FIFO threshold is reached before the list is completed. This allows the system designer to change the sweep sequence length. Once the FIFO has reached its programmed threshold, an interrupt (INT) is generated. The host must issue a read FIFO command to read and clear the FIFO before the next sweep can start. 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 TLC2554/TLC2558 conversion modes (continued) repeat sweep mode (mode 11) Repeat sweep mode (mode 11) works the same way as mode 10 except the operation has an option to continue even if the FIFO threshold is reached. Once the FIFO has reached its programmed threshold, an interrupt (INT) is generated. Then two things may happen: 1. The host may choose to act on it (read the FIFO) or ignore it. If the next cycle is a read FIFO cycle, all of the data stored in the FIFO is retained until it has been read in order. 2. If the next cycle is not a read FIFO cycle, or another CSTART is generated, all of the content stored in the FIFO is cleared before the next conversion result is stored in the FIFO, and the sweep is continued. Table 3. TLC2554/TLC2558 Conversion Mode CONVERSION MODE One shot Repeat Sweep Repeat sweep CFR D(6,5) 00 01 10 11 SAMPLING TYPE OPERATION Normal • • • • Single conversion from a selected channel CS or FS to start select/sampling/conversion/read One INT or EOC generated after each conversion Host must serve INT by selecting channel, and converting and reading the previous output. Extended • • • • • Single conversion from a selected channel CS to select/read CSTART to start sampling and conversion One INT or EOC generated after each conversion Host must serve INT by selecting next channel and reading the previous output. Normal • • • • Repeated conversions from a selected channel CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by either 1) (FIFO read) reading out all of the FIFO contents up to the threshold, then repeat conversions from the same selected channel or 2) writing another command(s) to change the conversion mode. If the FIFO is not read when INT is served, it is cleared. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. Normal • • • • One conversion per channel from a sequence of channels CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by (FIFO read) reading out all of the FIFO contents up to the threshold, then write another command(s) to change the conversion mode. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. Normal • • • • Repeated conversions from a sequence of channels CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by either 1) (FIFO read) reading out all of the FIFO contents up to the threshold, then repeat conversions from the same selected channel or 2) writing another command(s) to change the conversion mode. If the FIFO is not read when INT is served it is cleared. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. NOTE: Programming the EOC/INT pin as the EOC signal works for mode 00 only. The other three modes automatically generate an INT signal irrespective of whether EOC/INT is programmed. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 timing diagrams The timing diagrams can be categorized into two major groups: nonconversion and conversion. The nonconversion cycles are read and write (configuration). None of these cycles carry a conversion. Conversion cycles are those four modes of conversion. read cycle (read FIFO or read CFR) read CFR cycle: The read command is decoded in the first 4 clocks. SDO outputs the contents of the CFR after the 4th SCLK. 1 2 3 4 5 7 6 12 13 14 15 16 1 SCLK CS FS SDI INT EOC SDO ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎ ID15 ID14 ID13 ID12 ID15 OD11 OD10 OD9 OD4 OD3 OD2 OD1 OD0 Figure 2. TLC2554/TLC2558 Read CFR Cycle (FS active) 1 2 3 4 ID14 ID13 ID12 5 6 7 12 13 14 15 16 1 SCLK CS FS SDI INT EOC SDO ÎÎÎ ÎÎÎ ID15 ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ID15 ÎÎÎÎÎÎ OD11 OD10 OD9 OD4 OD3 OD2 OD1 OD0 Figure 3. TLC2554/TLC2558 Read CFR Cycle (FS = 1) 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 ID14 ÎÎÎÎ TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 read cycle (read FIFO or read CFR) (continued) FIFO read cycle The first command in the active cycle after INT is generated, if the FIFO is used, is assumed as the FIFO read command. The first FIFO content is output immediately before the command is decoded. If this command is not a FIFO read, then the output is terminated but the first data in the FIFO is retained until a valid FIFO read command is decoded. Use of more layers of the FIFO reduces the time taken to read multiple data. This is because the read cycle does not generate EOC or INT nor does it carry out any conversion. 1 2 3 4 ID14 ID13 ID12 OD11 OD10 OD9 OD8 5 6 7 12 13 14 15 16 1 SCLK CS ÎÎÎ ÎÎÎ FS SDI ID15 INT ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ID15 EOC SDO OD7 OD6 OD5 OD0 Figure 4. TLC2554/TLC2558 Continuous FIFO Read Cycle (FS = 1) (controlled by SCLK, SCLK can stop between each 16 SCLKs) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 ID14 ÎÎÎ ÎÎÎ 11 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 write cycle (write CFR) The write cycle is used to write to the configuration register CFR (with 12-bit register content). The write cycle does not generate an EOC or INT nor does it carry out any conversion. 1 2 3 4 5 6 ID11 ID10 7 12 13 14 15 16 1 SCLK CS ÎÎÎÎ ÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ FS SDI ID15 ID14 ID13 ID12 ID9 ID4 ID3 ID2 ID1 ID0 ID15 INT EOC SDO ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ Figure 5. TLC2554/TLC2558 Write Cycle (FS active) 1 2 3 4 5 6 7 12 13 ID15 ID14 ID13 ID12 ID11 ID10 ID9 ID4 ID3 14 15 16 ID1 ID0 ÎÎÎÎÎ ÎÎÎÎÎ 1 SCLK CS FS SDI INT EOC SDO ÎÎÎ ÎÎÎ ID2 ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ Figure 6. TLC2554/TLC2558 Write Cycle (FS = 1) 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 ID15 ID14 ÎÎÎÎ TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 conversion cycles DSP/normal sampling 1 2 3 4 ID13 ID12 5 6 7 12 13 14 15 16 28 1 SCLK CS ÎÎÎ ÎÎÎ FS SDI ID15 ID14 ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ID15 INT tsample (Long) tconv tsample (Short) EOC t conv SDO OD10 OD9 OD8 OD11 OD7 OD6 OD5 OD0 Figure 7. Mode 00 Single Shot/Normal Sampling (FS signal used) 1 2 3 4 5 6 7 12 13 14 15 16 ÎÎÎÎÎ ÎÎÎÎÎ 28 1 SCLK CS ÎÎÎ ÎÎÎ FS SDI ID15 ID14 ID13 ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ID12 INT ID14 tsample (Long) tconv tsample (Short) EOC t conv SDO ID15 OD11 OD10 OD9 OD8 OD7 OD6 OD5 OD0 ÎÎÎÎ ÎÎÎÎ Figure 8. Mode 00 Single Shot/Normal Sampling (FS = 1, FS signal not used) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 conversion cycles (continued) Select/Read Cycle Select/Read Cycle CS tsample CSTART ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ FS tconvert † SDI INT EOC SDO Previous Conversion Result Hi-Z Previous Conversion Result Hi-Z Hi-Z † This is one of the single shot commands. Conversion starts on next rising edge of CSTART. Figure 9. Mode 00 Single Shot/Extended Sampling (FS signal used, FS pin connected to TMS320 DSP) CS used as FS input When interfacing with the TMS320 DSP using conversion mode 00, the FSR signal from the DSP may be connected to the CS input if this is the only device on the serial port. This will save one output pin from the DSP. Output data is made available on the rising edge of SCLK and input data is latched on the rising edge of SCLK in this case. modes using the FIFO: modes 01, 10, 11 timing Modes 01, 10, and 11 timing are very similar except for how and when the FIFO is read, how the device is configured, and how channel(s) are selected. Mode 01 (repeat mode) requires a two-cycle configuration where the first one sets the mode and the second one selects the channel. Once the FIFO is filled up to the threshold programmed, it has the option to either read the FIFO or configure for other modes. Therefore, the sequence is either configure: select : triggered conversions : FIFO read : select : triggered conversions : FIFO read or configure : select : triggered conversions : configure : .... Each configure clears the FIFO and the action that follows the configure command depends on the mode setting of the device. 14 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 modes using the FIFO: modes 01, 10, 11 timing (continued) Configure Select Conversion #1 From Channel 2 Conversion #4 From Channel 2 Select CS FS tsample tsample tsample tconvert tconvert tconvert CSTART ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ † SDI § ‡ ‡ ‡ ‡ § INT Hi-Z Hi-Z SDO Read FIFO #1 Top of FIFO #2 #3 #4 Next #1 † Command = Configure write for mode 01, FIFO threshold = 1/2 ‡ Command = Read FIFO, 1st FIFO read § Command = Select ch2. Figure 10. TLC2554/TLC2558 Mode 01 DSP Serial Interface (conversions triggered by FS) Conversion #1 From Channel 2 Conversion #4 From Channel 2 Configure Select Select CS FS (DSP) tsample(2) tsample(1) tsample(3) tsample(4) CSTART tconvert(1) tconvert(2) tconvert(4) tconvert(3) ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ SDI † § ‡ ‡ ‡ ‡ § INT SDO Hi-Z Hi-Z tSample(i) > = MIN(tSample) Read FIFO #1 #2 First FIFO Read #3 #4 Next #1 † Command = Configure write for mode 01, FIFO threshold = 1/2 ‡ Command = Read FIFO, 1st FIFO read § Command = Select ch2. Figure 11. TLC2554/TLC2558 Mode 01 µp/DSP Serial Interface (conversions triggered by CSTART) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 modes using the FIFO: modes 01, 10, 11 timing (continued) Mode 10 (sweep mode) requires reconfiguration at the start of each new sweep sequence. Once the FIFO is filled up to the programmed threshold, the host has the option to either read the FIFO or configure for other modes. Once the FIFO is read, the host must reconfigure the device before the next sweep sequence can be started. So the sequence is either configure : triggered conversions : FIFO read : configure. or configure : triggered conversions : configure : .... Each configure clears the FIFO and the action that follows the configure command depends on the mode setting of the device. Mode 11 (repeat sweep mode) requires one cycle configuration. This sweep sequence can be repeated without reconfiguration. Once the FIFO is filled up to the programmed threshold, the host has the option to either read the FIFO or configure for other modes. So the sequence is either configure : triggered conversions : FIFO read : triggered conversions : FIFO read ... or configure : triggered conversions : configure : .... Each configure clears the FIFO and the action that follows the configure command depends on the mode setting of the device. Conversion From Channel 0 Configure Conversion From Channel 3 Conversion From Channel 0 Conversion From Channel 3 CS tsample(3) tsample(2) tsample(4) tsample(1) FS (DSP) tconvert tconvert CSTART SDI INT ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tSample(i) > = MIN(tSample) ‡ † ‡ ‡ ‡ ‡ SDO Repeat Read FIFO #1 #2 #3 Top of FIFO First FIFO Read #4 Repeat Read FIFO Second FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0–1–2–3. ‡ Command = Read FIFO Figure 12. TLC2554/TLC2558 Mode 10/11 DSP Serial Interface (conversions triggered by FS) 16 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 #1 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 modes using the FIFO: modes 01, 10, 11 timing (continued) Conversion From Channel 0 Conversion From Channel 3 Conversion From Channel 0 Configure Conversion From Channel 3 CS tsample(i) >= MIN (tsample) FS (DSP) CSTART tsample (1) tsample (2) tsample (3) tsample (4) tconvert SDI INT ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎ tconvert ‡ † ‡ ‡ ‡ #3 #4 ‡ SDO Read FIFO Repeat #1 #2 Top of FIFO Repeat Read FIFO #1 Second FIFO Read First FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0–1–2–3. ‡ Command = Read FIFO Figure 13. TLC2554/TLC2558 Mode 10/11 DSP Serial Interface (conversions triggered by CSTART) Conversion From Channel 0 Conversion From Channel 3 Conversion From Channel 0 Conversion From Channel 3 Configure CS tsample(1) tsample(2) tsample(3) tsample(4) tconvert tconvert tSample (i) > = MIN(tSample) CSTART ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ SDI ‡ † ‡ ‡ ‡ ‡ INT SDO Read FIFO Repeat #1 #2 #3 Top of FIFO First FIFO Read #4 Read FIFO #1 Repeat Second FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0–1–2–3. ‡ Command = Read FIFO Figure 14. TLC2554/TLC2558 Mode 00/11 µp Serial Interface (conversions triggered by CS) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 FIFO operation Serial OD 12-BIT×8 FIFO ADC 7 6 FIFO Full 5 4 3 2 1 0 FIFO 1/2 Full FIFO 3/4 Full FIFO 1/4 Full FIFO Threshold Pointer Figure 15. TLC2554/TLC2558 FIFO The device has an 8 layer FIFO that can be programmed for different thresholds. An interrupt is sent to the host after the preprogrammed threshold is reached. The FIFO can be used to store data from either a fixed channel or a series of channels based on a preprogrammed sweep sequence. For example, an application may require eight measurements from channel 3. In this case, the FIFO is filled with 8 data sequentially taken from channel 3. Another application may require data from channel 0, channel 2, channel 4, and channel 6 in an orderly manner. Therefore, the threshold is set for 1/2 and the sweep sequence 0–2–4–6–0–2–4–6 is chosen. An interrupt is sent to the host as soon as all four data are in the FIFO. SCLK and conversion speed There are multiple ways to adjust the conversion speed. The maximum equivalent conversion clock (fSCLK/DIV) should not exceed 10 MHz. D The SCLK is used as the source of the conversion clock and 14 conversion clocks are required to complete a conversion plus 4 SCLKs overhead. The devices can operate with an SCLK up to 20 MHz for the supply voltage range specified. The clock divider provides speed options appropriate for an application where a high speed SCLK is used for faster I/O. The total conversion time is 14 × (DIV/fSCLK) where DIV is 1 or 2. For example a 20-MHz SCLK with the divide by 2 option produces a {14 × (2/20 M) + 4 × (1/20 MHz)} = 1.6 µs conversion time. D Auto power down can be used. This mode is always on. If the device is not accessed (by CS or CSTART), the converter is powered down to save power. The built-in reference is left on in order to quickly resume operation within one half SCLK period. This provides unlimited choices to trade speed with power savings. reference voltage The device has a built-in reference with a level of 4 V. If the internal reference is used, REFP is set to 4 V and REFM is set to 0 V. An external reference can also be used through two reference input pins, REFP and REFM, if the reference source is programmed as external. The voltage levels applied to these pins establish the upper and lower limits of the analog inputs to produce a full-scale and zero-scale reading respectively. The values of REFP, REFM, and the analog input should not exceed the positive supply or be lower than GND consistent with the specified absolute maximum ratings. The digital output is at full scale when the input signal is equal to or higher than REFP and at zero when the input signal is equal to or lower than REFM. 18 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 FIFO operation (continued) power down Writing 8000h to the device puts the device into a software power-down state. For a hardware power down, the dedicated PWDN pin provides another way to power down the device asynchronously. These two power-down modes power down the entire device including the built-in reference to save power. It requires 20 ms to resume from either a software or hardware power down. Auto power down mode is always enabled. This mode maintains the built-in reference if an internal reference is used, so resumption is fast enough to be used between cycles. The configuration register is not affected by any of the power down modes but the sweep operation sequence has to be started over again. All FIFO contents are cleared by the power-down modes. power up and initialization Initialization requires: 1. Determine processor type by writing A000h to the TLC2554/58 2. Configure the device The first conversion after power up or resuming from power down is not valid. absolute maximum ratings over operating free-air temperature (unless otherwise noted)† Supply voltage range, GND to VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6.5 V Analog input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VCC + 0.3 V Reference input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.3 V Digital input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VCC + 0.3 V Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 150°C Operating free-air temperature range, TA: TLC2554/58C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C TLC2554/58I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 85°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions Supply voltage, VCC MIN NOM MAX 4.5 5 5.5 V VCC 2 V VCC VCC+0.2 VCC V Positive external reference voltage input, VREFP (see Note 1) Negative external reference voltage input, VREFM (note Note 1) 2 Differential reference voltage input, VREFP – VREFM (see Note 1) 2 Analog input voltage (see Note 1) 0 0 High level control input voltage, VIH 2.1 Low-level control input voltage, VIL UNIT V V V 0.6 V Rise time, for CS, CSTART SDI at 0.5 pF, tr(I/O) 4.76 ns Fall time, for CS, CSTART SDI at 0.5 pF, tf(I/O) 2.91 ns Rise time, for INT, EOC, SDO at 30 pF, tr(Output) 2.43 ns Fall time, for INT, EOC, SDO at 30 pF, tf(Output) 2.3 ns NOTE 1: When binary output format is used, analog input voltages greater than that applied to REFP convert as all ones (111111111111), while input voltages less than that applied to REFM convert as all zeros (000000000000). The device is functional with reference down to 2 V (VREFP – VREFM –1); however, the electrical specifications are no longer applicable. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 19 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 recommended operating conditions (continued) MIN Transition time, for FS, SCLK, SDI, tt(CLK) Setup time, CS falling edge before SCLK rising edge (FS=1) or before SCLK falling edge (when FS is active), tsu(CS-SCLK) Hold time, CS rising edge after SCLK rising edge (FS=1) or after SCLK falling edge (when FS is active), th(SCLK-CS) Delay time, delay from CS falling edge to FS rising edge, td(CSL-FSH) Delay time, delay time from 16th SCLK falling edge to CS rising edge (FS is active), td(SCLK16F-CSH) NOM MAX UNIT 0.5 SCLK 0.5 SCLK 5 0.5 ns 7 0.5 Setup time, FS rising edge before SCLK falling edge, tsu(FSH-SCLKF) SCLKs SCLKs 0.5 SCLKs Hold time, FS hold high after SCLK falling edge, th(FSH-SCLKF) 0.5 SCLKs Pulse width, CS high time, twH(CS) 100 ns SCLK cycle time, VCC = 2.7 V to 3.6V, tc(SCLK) 67 ns SCLK cycle time, VCC = 4.5 V to 5.5V, tc(SCLK) Pulse width, SCLK low time, twL(SCLK) 50 20 30 ns Pulse width, SCLK high time, twH(SCLK) 20 30 ns 25 ns ns Setup time, SDI valid before falling edge of SCLK (FS is active) or the rising edge of SCLK (FS=1), tsu(DI-SCLK) Hold time, SDI hold valid after falling edge of SCLK (FS is active) or the rising edge of SCLK (FS=1), th(DI-SCLK) Delay time, delay from CS falling edge to SDO valid, td(CSL-DOV) 5 1 25 ns Delay time, delay from FS falling edge to SDO valid, td(FSL-DOV) 1 25 ns Delay time, delay from SCLK rising edge (FS is active) or SCLK falling edge (FS=1) SDO valid, td(CLK-DOV) 1 25 ns Delay time, delay from CS rising edge to SDO 3-stated, td(CSH-DOZ) 1 25 ns Delay time, delay from 16th SCLK falling edge (FS is active) or the 16th rising edge (FS=1) to EOC falling edge, td(CLK-EOCL) 1 25 ns Delay time, delay from EOC rising edge to SDO 3-stated if CS is low, td(EOCH-DOZ) 1 50 ns 3.5 µs 50 ns Delay time, delay from 16th SCLK rising edge to INT falling edge (FS =1) or from the 16th falling edge SCLK to INT falling edge (when FS active), td(SCLK-INTL) Delay time, delay from CS falling edge to INT rising edge, td(CSL-INTH) Delay time, delay from CS rising edge to CSTART falling edge, td(CSH-CSTARTL) Delay time, delay from CSTART rising edge to EOC falling edge, td(CSTARTH-EOCL) Pulse width, CSTART low time, twL(CSTART) 1 ns 100 1 ns 50 Delay time, delay from CS rising edge to EOC rising edge, td(CSH-EOCH) 1 Delay time, delay from CSTART rising edge to CSTART falling edge, td(CSTARTH-CSTARTL) 3.6 Delay time, delay from CSTART rising edge to INT falling edge, td(CSTARTH-INTL) 3.5 TLC2554C/TLC2558C free air temperature, temperature TA Operating free-air TLC2554I/TLC2558I ns µs 0.8 50 ns µs µs 0 70 –40 85 _C NOTE 2: This is the time required for the clock input signal to fall from VIH max or to rise from VILmax to VIHmin. In the vicinity of normal room temperature, the devices function with input clock transition time as slow as 1 µs for remote data-acquisition applications where the sensor and A/D converter are placed several feet away from the controlling microprocessor. 20 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 electrical characteristics over recommended operating free-air temperature range, VCC = VREFP = 4.5 V to 5.5 V, SCLK frequency = 20 MHz at 5 V, (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT VOH High-level output voltage VCC = 5.5 V, IOH = –20 µA at 30 pF load VOL Low-level output voltage VCC = 5.5 V, IOL = 20 µA at 30 pF load IOZ O s a e ou Off-state output u cu current e (high-impedance-state) VO = 0 IIH High-level input current IIL Low-level input current O e a g supply Operating su y current, cu e , normal o a sampling sa g (short) CS at 0 V, Ext ref VCC = 4.5 V to 5.5 V CS at 0 V, Int ref VCC = 4.5 V to 5.5 V CS at 0 V, Ext ref VCC = 4.5 V to 5.5 V 1.9 mA CS at 0 V, Int ref VCC = 4.5 V to 5.5 V 2 mA ICC ICC VO = VCC Operating supply current, current extended sampling ICC(PD) ICC(AUTOPWDN) 1 2.5 -2.5 VI = VCC 0.005 2.5 VI = 0 V –0.005 2.5 µA 4 mA 6 mA Power-down supply current For all digital inputs, 0≤ VI ≤ 0.3 V or VI ≥ VCC– 0.3 V, SCLK = 0, VCC = 4.5 V to 5.5 V, Ext clock Auto power-down current For all digital inputs, 0≤ VI ≤ 0.3 V or VI ≥ VCC– 0.3 V, SCLK = 0, VCC = 4.5 V to 5.5 V, Ext clock, Ext ref Ci Input capacitance Zi Input MUX ON resistance V –1 CS at 0 V, VCC = 4.5 V to 5.5 V Maximum static analog reference current into REFP (use external reference) V 0.4 CS = VCC Internal reference supply current Selected channel leakage current 2.4 0.1 mA 1 µA 5‡ µA 1 Selected channel at 0 V –1 1 Analog inputs 45 50 Control Inputs 5 25 VCC = 5.5 V µA 2 Selected channel at VCC VREFP = VCC = 5.5 V, VREFM = GND µA 500 µA µA pF Ω † All typical values are at VCC = 5 V, TA = 25°C. ‡ 800 µA if internal reference is used. ac specifications PARAMETER SINAD Signal-to-noise ratio +distortion THD Total harmonic distortion ENOB Effective number of bits SFDR Spurious free dynamic range TEST CONDITIONS MIN fI = 12 kHz at 400 KSPS fI = 12 kHz at 400 KSPS 69 fI = 12 kHz at 400 KSPS fI = 12 kHz at 400 KSPS TYP MAX 71 –82 dB –76 11.6 –84 UNIT dB Bits –75 dB Analog input Full power bandwidth, –3 dB 1 MHz Full power bandwidth, –1 dB 500 kHz POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 21 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 reference specifications (0.1 µF and 10 µF between REFP and REFM pins) PARAMETER TEST CONDITIONS Reference input voltage, REFP VCC = 4.5 V Input impedance VCC = 5 5V 5.5 Input voltage difference, REFP – REFM VCC = 4.5 V VCC = 5.5 V Internal reference voltage,REFP – REFM Internal reference start up time VCC = 5.5 V VCC = 4.5 V Reference temperature coefficient CS = 1, SCLK = 0, (off) CS = 0, SCLK = 20 MHz (on) MIN TYP UNIT VCC V 100 MΩ 20 25 2 Reference select = internal MAX 3.85 4 10 µF kΩ VCC 4.15 20 16 V V ms 40 PPM/°C operating characteristics over recommended operating free-air temperature range, VCC = VREFP = 4.5 V, SCLK frequency = 20 MHz (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP† Integral linearity error (INL) (see Note 4) Differential linearity error (DNL) See Note 3 EO EG Offset error (see Note 5) See Note 3 Gain error (see Note 5) See Note 3 ET Total unadjusted error (see Note 6) Self-test output code (see Table 1 and Note 7) tconv Conversion time tsample tt(I/O) Sampling time ±1 SDI = B000h 800h (2048D) SDI = C000h 000h (0D) SDI = D000h FFFh (4095D) MAX UNIT ±1 LSB ±1 LSB ±2.5 LSB ±2 LSB ±2 LSB (14XDIV) fSCLK External SCLK At 1 kΩ Transition time for EOC, INT 600 ns 50 ns tt(CLK) Transition time for SDI, SDO 25 ns † All typical values are at TA = 25°C. NOTES: 3. Analog input voltages greater than that applied to REFP convert as all ones (111111111111), while input voltages less than that applied to REFM convert as all zeros (0000000000). The device is functional with reference down to 2 V (VREFP – VREFM); however, the electrical specifications are no longer applicable. 4. Linear error is the maximum deviation from the best straight line through the A/D transfer characteristics. 5. Zero error is the difference between 000000000000 and the converted output for zero input voltage: full-scale error is the difference between 111111111111 and the converted output for full-scale input voltage. 6. Total unadjusted error comprises linearity, zero, and full-scale errors. 7. Both the input data and the output codes are expressed in positive logic. 22 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PARAMETER MEASUREMENT INFORMATION tt(I/O) 90% 50% 10% CS tt(I/O) VIH VIL twH(CS) td(CSL-FSH) VIH FS VIL tsu(FSH-SCLKF) th(FSH-SCLKF) td(SCLK16F-CSH) twH(SCLK) twL(SCLK) th(SCLK-CS) tsu(CS-SCLK) 1 16 VIH SCLK tc(SCLK) VIL tsu(DI-CLK) ÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎ SDI td(FSL-DOV) td(CSL-DOV) th(DI-CLK) ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ VIH ID15 ID1 VIL td(CLK-DOV) VOH Hi-Z SDO VOL td(CLK-EOCL) td(EOCH–DOZ) VOH EOC VOL td(SCLK-INTL) td(CSL-INTH) VOH INT VOL Figure 16. Critical Timing (normal sampling, FS is active) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 23 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PARAMETER MEASUREMENT INFORMATION VIH CS VIL td(CSH-CSTARTL) twL(CSTART) VIH CSTART VIL td(CSH-EOCH) tt(I/O) tt(I/O) tconvert VOH EOC VOL td(CSTARTH-EOCL) td(EOCH-INTL) td(CSL-INTH) VOH INT VOL Figure 17. Critical Timing (extended sampling, single shot) VIH CS twL(CSTART) td(CSL-CSTARTL) VIL td(CSTARTH–CSTARTL) VIH 90% 50% 10% CSTART td(CSH-EOCH) tt(I/O) VIL tt(I/O) VOH EOC VOL td(CSTARTH-EOCL) td(CSTARTH-INTL) td(CSL-INTH) INT VOL Figure 18. Critical Timing (extended sampling, repeat/sweep/repeat sweep) 24 VOH POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PARAMETER MEASUREMENT INFORMATION tt(I/O) tt(I/O) VIH CS twH(CS) tsu(CS-SCLK) VIL td(SCLK16F-CSH) twL(SCLK) tt(CLK) twH(SCLK) 1 16 VIH SCLK VIL tc(SCLK) tsu(DI-CLK) SDI th(DI-CLK) ÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ ID15 td(CSL-DOV) SDO Hi-Z ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ID1 VIH VIL td(CLK-DOV) OD15 OD1 VOH Hi-Z OD0 VOL td(EOCH-DOZ) td(CLK-EOCL) VOH ECO VOL td(SCLK-INTL) td(CSL-INTH) VOH INT VOL Figure 19. Critical Timing (normal sampling, FS = 1) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 25 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 TYPICAL CHARACTERISTICS DIFFERENTIAL NONLINEARITY vs TEMPERATURE INTEGRAL NONLINEARITY vs TEMPERATURE 0.5 0.53 VCC = 5 V, Internal Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode DNL – Differential Nonlinearity – LSB INL – Integral Nonlinearity – LSB 0.55 0.51 0.49 0.47 0.45 –40 25 TA – Temperature – °C 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 –40 85 Figure 20 0 1.7 1.6 1.5 1.4 1.3 1.2 –0.5 –1 –1.5 Gain Error – LSB Offset Error – LSB 85 GAIN ERROR vs TEMPERATURE 1.1 1 0.9 0.8 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode 25 TA – Temperature – °C –2 –2.5 –3 –3.5 –4 –4.5 85 –5 –40 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode 25 TA – Temperature – °C Figure 22 26 25 TA – Temperature – °C Figure 21 OFFSET ERROR vs TEMPERATURE 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 –40 VCC = 5 V, Internal Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode Figure 23 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 85 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 TYPICAL CHARACTERISTICS POWER DOWN CURRENT vs TEMPERATURE SUPPLY CURRENT vs TEMPERATURE 0.5 4 3.7 0.3 3.6 3.5 3.4 0.2 0 –0.1 –0.2 3.2 –0.3 3.1 –0.4 3 –40 25 TA – Temperature – °C VCC = 5.5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode 0.1 3.3 –0.5 –40 85 25 85 TA – Temperature – °C Figure 24 Figure 25 INTEGRAL NONLINEARITY vs SAMPLES INL – Integral Nonlinearity – LSB Supply Current – mA 3.8 0.4 Power Down – µ A 3.9 VCC = 5.5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 µP mode 1.0 VCC = 5 V, External Reference = 5 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 0.8 0.6 0.4 0.2 –0.0 –0.2 –0.4 –0.6 –0.8 –1.0 0 2048 4096 Samples Figure 26 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 27 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 DNL – Differential Nonlinearity – LSB TYPICAL CHARACTERISTICS DIFFERENTIAL NONLINEARITY vs SAMPLES 1.0 VCC = 5 V, External Reference = 5 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 0.8 0.6 0.4 0.2 –0.0 –0.2 –0.4 –0.6 –0.8 –1.0 0 2048 4096 Samples Figure 27 INL – Integral Nonlinearity – LSB INTEGRAL NONLINEARITY vs SAMPLES 1.0 VCC = 5 V, Internal Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 0.8 0.6 0.4 0.2 –0.0 –0.2 –0.4 –0.6 –0.8 –1.0 0 2048 Samples Figure 28 28 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 4096 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 TYPICAL CHARACTERISTICS DNL – Differential Nonlinearity – LSB DIFFERENTIAL NONLINEARITY vs SAMPLES 1.0 VCC = 5 V, Internal Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 0.8 0.6 0.4 0.2 –0.0 –0.2 –0.4 –0.6 –0.8 –1.0 0 2048 4096 Samples Figure 29 FAST POURIER TRANSFORM vs FREQUENCY 0 AIN = 50 kHz VCC = 5 V, Channel 0 External Reference = 4 V SCLK = 20 MHz Single Shot, Short Sample Mode 00 DSP Mode Magnitude – dB –20 –40 –60 –80 –100 –120 –140 0 50 100 150 200 f – Frequency – kHz Figure 30 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 29 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 TYPICAL CHARACTERISTICS EFFECTIVE NUMBER OF BITS vs INPUT FREQUENCY SIGNAL-TO-NOISE + DISTORTION vs INPUT FREQUENCY 12.00 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 75 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode 11.80 ENOB – Effective Number of Bits – BITS SINAD – Signal-to-Noise + Distortion – dB 80 70 65 60 55 50 45 11.60 11.40 11.20 11.00 10.80 10.60 10.40 10.20 10.00 9.80 9.60 9.40 9.20 40 9.00 0 100 200 0 100 f – Frequency – kHz f – Frequency – kHz Figure 31 Figure 32 TOTAL HARMONIC DISTORTION vs INPUT FREQUENCY SPURIOUS FREE DYNAMIC RANGE vs INPUT FREQUENCY 0 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode –55 Spurious Free Dynamic Range – dB THD – Total Harmonic Distortion – dB –50 –60 –65 –70 –75 –80 VCC = 5 V, External Reference = 4 V, SCLK = 20 MHz, Single Shot, Short Sample, Mode 00 DSP Mode –20 –40 –60 –80 –100 0 25 50 75 100 125 150 f – Frequency – kHz 175 200 0 25 50 75 100 Figure 34 POST OFFICE BOX 655303 125 f – Frequency – kHz Figure 33 30 200 • DALLAS, TEXAS 75265 150 175 200 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION 4095 1111111111 VFS See Notes A and B 1111111110 4094 1111111101 4093 VFT = VFS – 1/2 LSB 2049 1000000001 2048 1000000000 VZT =VZS + 1/2 LSB Step Digital Output Code VFS Nom 2047 0111111111 VZS 0000000001 1 0000000000 0 0.0012 0.0024 2.4564 2.4576 2.4588 4.9134 2 0.0006 0000000010 4.9056 4.9104 0 4.9152 VI – Analog Input Voltage – V NOTES: A. This curve is based on the assumption that Vref+ and Vref– have been adjusted so that the voltage at the transition from digital 0 to 1 (VZT) is 0.0006 V, and the transition to full scale (VFT) is 4.9134 V, 1 LSB = 1.2 mV. B. The full scale value (VFS) is the step whose nominal midstep value has the highest absolute value. The zero-scale value (VZS) is the step whose nominal midstep value equals zero. Figure 35. Ideal 12-Bit ADC Conversion Characteristics vcc 10 kΩ VDD XF CS TXD SDI RXD SDO AIN CLKR CLKX TMS320 DSP BIO FSR FSX INT SCLK TLC2554/ TLC2558 FS GND Figure 36. Typical Interface to a TMS320 DSP POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 31 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION simplified analog input analysis Using the equivalent circuit in Figure 39, the time required to charge the analog input capacitance from 0 to VS within 1/2 LSB can be derived as follows. ǒ ǒ ǓǓ The capacitance charging voltage is given by: Vc + Vs 1–EXP –tc Rt (1) Ci Where Rt = Rs + Zi tc = Cycle time ǒ Ǔ ǒ Ǔ + ǒ ǒ ǓǓ The input impedance Zi is 0.5 kΩ at 5 V. The final voltage to 1/2 LSB is given by: ń VC (1 2 LSB) + VS– VS 8192 (2) Equating equation 1 to equation 2 and solving for cycle time tc gives: Vs– VS 8192 Vs 1–EXP –tc Rt (3) Ci and time to change to 1/2 LSB (minimum sampling time) is: ń tch (1 2 LSB) Where + Rt Ci In(8192) In(8192) = 9.011 Therefore, with the values given, the time for the analog input signal to settle is: ń tch (1 2 LSB) + (Rs ) 0.5 kW) Ci (4) In(8192) This time must be less than the converter sample time shown in the timing diagrams. This is 12× SCLKs (if the sampling mode is short normal sampling mode). ń tch (1 2 LSB) v 12 1 f (SCLK) (5) Therefore the maximum SCLK frequency is: ƪ max f ( SCLK ) 32 ƫ + tch ǒ112ń2 LSBǓ + [In(8192)12 Rt POST OFFICE BOX 655303 Ci ] • DALLAS, TEXAS 75265 (6) TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION Driving Source† TLC2554/58 Rs VS VI = Input Voltage at AIN VS = External Driving Source Voltage Rs = Source Resistance ri = Input Resistance (MUX on Resistance) Ci = Input Capacitance VC = Capacitance Charging Voltage ri VI VC Ci † Driving source requirements: • Noise and distortion for the source must be equivalent to the resolution of the converter. • Rs must be real at the input frequency. Figure 37. Equivalent Input Circuit Including the Driving Source maximum conversion throughput For a supply voltage of 5 V, if the source impedance is less than 1 kΩ, and the ADC analog input capacitance Ci is less than 50 pF, this equates to a minimum sampling time tch(0.5 LSB) of 0.676 µs. Since the sampling time requires 12 SCLKs, the fastest SCLK frequency is 12/tch = 18 MHz. The minimal total cycle time is given as: tc + tcommand ) tch ) tconv ) td(EOCH–CSL ) + 4 + 16 18 1MHz ) 1.7 ms + 2.59 ms 1 f (SCLK) ) 12 1 f (SCLK) ) 1.6 ms ) 0.1 ms This is equivalent to a maximum throughput of 386 KSPS. The throughput can be even higher with a smaller source impedance. When source impedance is 100 Ω, the minimum sampling time becomes: ń tch (1 2 LSB) + Rt Ci In(8192) + 0.27 ms The maximum SCLK frequency possible is 12/tch = 44 MHz. Then a 20 MHz clock (maximum SCLK frequency for the TLC2554/2548 ) can be used. The minimal total cycle time is then reduced to: tc + tcommand ) tch ) tconv ) td(EOCH–CSL ) + 4 + 0.8 ms ) 1.6 ms ) 0.1 ms + 2.5 ms 1 f (SCLK) ) 12 1 f (SCLK) ) 1.6 ms ) 0.1 ms The maximum throughput is 1/2.5 µs = 400 KSPS for this case. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 33 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION power down calculations i(AVERAGE) = (fS /fSMAX ) × i(ON) + (1–fS /fSMAX ) × i(OFF) CASE 1: If VDD = 3.3 V, auto power down, and an external reference is used: + 10 kHz + 200 kHz f SMAX i (ON) +X 1 mA operating current and i (OFF) +X 1 mA auto power-down current f S so i (AVERAGE) + 0.05 1000 mA ) 0.95 1 mA + 51 mA CASE 2: Now if software power down is used, another cycle is needed to shut it down. + 20 kHz + 200 kHz f SMAX i (ON) +X 1 mA operating current and i (OFF) +X 1 mA power-down current f S so i (AVERAGE) + 0.1 1000 mA ) 0.9 1 mA + 101 mA In reality this will be less since the second conversion never happened. It is only the additional cycle to shut down the ADC. 34 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION CASE 3: Now if the hardware power down is used. + 10 kHz + 200 kHz f SMAX i (ON) +X 1 mA operating current and i (OFF) +X 1 mA power-down current f S so i (AVERAGE) + 0.05 1000 mA ) 0.95 1 mA + 51 mA difference between modes of conversion The major difference between sweep mode (mode 10) and repeat sweep mode (mode 11) is that the sweep sequence ends after the FIFO is filled up to the programmed threshold. The repeat sweep can either dump the FIFO (by ignoring the FIFO content but simply reconfiguring the device) or read the FIFO and then repeat the conversions on the the same sequence of the channel as before. FIFO reads are expected after the FIFO is filled up to the threshold in each case. Mode 10 – the device allows only FIFO read or CFR read or CFR write to be executed. Any conversion command is ignored. In the case of mode 11, in addition to the above commands, conversion commands are also executed , i.e. the FIFO is cleared and the sweep sequence is restarted. Both single shot and repeat modes require selection of a channel after the device is configured for these modes. Single shot mode does not use the FIFO, but repeat mode does. When the device is operating in repeat mode, the FIFO can be dumped (by ignoring the FIFO content and simply reconfiguring the device) or the FIFO can be read and then the conversions repeated on the same channel as before. However, the channel has to be selected first before any conversion can be carried out. The devices can be programmed with the following sequences for operating in the different modes that use a FIFO: POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 35 TLC2554, TLC2558 5-V, 12-BIT, 400 KSPS, 4/8 CHANNEL, LOW POWER, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTO POWER DOWN SLAS220A –JUNE 1999 PRINCIPLES OF OPERATION difference between modes of conversion (continued) REPEAT: Configure FIFO Depth=4 /CONV Mode 01 Select Channel/ 1st Conv (CS or CSTART) 2nd Conv (CS or CSTART) 3rd Conv (CS or CSTART) 4th Conv (CS or CSTART FIFO READ 1 FIFO READ 2 FIFO READ 3 FIFO READ 4 Select Channel 1st Conv (CS or CSTART) 2nd Conv (CS or CSTART) 3rd Conv (CS or CSTART) 4th Conv (CS or CSTART SWEEP: Configure FIFO Depth=4 SEQ=1–2–3–4/CONV Mode 10 conv ch 1 (CS/CSTART) conv ch 2 (CS/CSTART) conv ch 3 (CS/CSTART) conv ch 4 (CS/CSTART FIFO READ ch 1 result FIFO READ ch 2 result FIFO READ ch 3 result FIFO READ ch 4 result Configure (not required if same sweep sequence is to be used again) REPEAT SWEEP: Configure FIFO Depth=4 SWEEP SEQ=1-2-3-4/CONV Mode 11 conv ch 1 (CS/CSTART) conv ch 2 (CS/CSTART) conv ch 3 (CS/CSTART) conv ch 4 (CS/CSTART FIFO READ ch 1 result FIFO READ ch 2 result FIFO READ ch 3 result FIFO READ ch 4 result conv ch 1 (CS/CSTART) conv ch 2 (CS/CSTART) conv ch 3 (CS/CSTART) conv ch 4 (CS/CSTART 36 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PACKAGE OPTION ADDENDUM www.ti.com 14-Oct-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) Samples (4/5) (6) TLC2554ID ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TLC2554I Samples TLC2554IPW ACTIVE TSSOP PW 16 90 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 Y2554 Samples TLC2558CDW ACTIVE SOIC DW 20 25 RoHS & Green NIPDAU Level-1-260C-UNLIM TLC2558C Samples TLC2558IDW ACTIVE SOIC DW 20 25 RoHS & Green NIPDAU Level-1-260C-UNLIM TLC2558I Samples TLC2558IPW ACTIVE TSSOP PW 20 70 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 Y2558 Samples TLC2558IPWR ACTIVE TSSOP PW 20 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 Y2558 Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TLC2558IPWR 价格&库存

很抱歉,暂时无法提供与“TLC2558IPWR”相匹配的价格&库存,您可以联系我们找货

免费人工找货