TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
D
D
D
D
D
D
D
Very Low Power Consumption . . . 2 mW
Typ at VDD = 5 V
Capable of Operation in Astable Mode
CMOS Output Capable of Swinging Rail to
Rail
High Output-Current Capability
Sink 100 mA Typ
Source 10 mA Typ
Output Fully Compatible With CMOS, TTL,
and MOS
Low Supply Current Reduces Spikes
During Output Transitions
Single-Supply Operation From 2 V to 15 V
Functionally interchangeable With the
NE556; Has Same Pinout
D, J, OR N PACKAGE
(TOP VIEW)
1 DISCH
1 THRES
1 CONT
1 RESET
1 OUT
1 TRIG
GND
14
2
13
3
12
4
11
5
10
6
9
7
8
VDD
2 DISCH
2 THRES
2 CONT
2 RESET
2 OUT
2 TRIG
FK PACKAGE
(TOP VIEW)
description
1 CONT
NC
1 RESET
NC
1 OUT
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
2 THRES
NC
2 CONT
NC
2 RESET
1 TRIG
GND
NC
2 TRIG
2 OUT
The TLC556 series are monolithic timing circuits
fabricated using the TI LinCMOS process, which
provides full compatibility with CMOS, TTL, and
MOS logic and operates at frequencies up to
2 MHz. Accurate time delays and oscillations are
possible with smaller, less-expensive timing
capacitors than the NE556 because of the high
input impedance. Power consumption is low
across the full range of power supply voltages.
1
1 THRES
1 DISCH
NC
V DD
2 DISCH
D
NC–No internal connection
Like the NE556, the TLC556 has a trigger level
approximately one-third of the supply voltage and
a threshold level approximately two-thirds of the supply voltage. These levels can be altered by use of the control
voltage terminal. When the trigger input falls below the trigger level, the flip-flop is set and the output goes high.
If the trigger input is above the trigger level and the threshold input is above the threshold level, the flip-flop is
reset and the output is low. The reset input can override all other inputs and can be used to initiate a new timing
cycle. If the reset input is low, the flip-flop is reset and the output is low. Whenever the output is low, a
low-impedance path is provided between the discharge terminal and ground.
While the CMOS output is capable of sinking over 100 mA and sourcing over 10 mA, the TLC556 exhibits greatly
reduced supply-current spikes during output transitions. This minimizes the need for the large decoupling
capacitors required by the NE556.
These devices have internal electrostatic-discharge (ESD) protection circuits that prevent catastrophic failures
at voltages up to 2000 V as tested under MIL-STD-883C, Method 3015. However, care should be exercised in
handling these devices, as exposure to ESD may result in degradation of the device parametric performance.
All unused inputs should be tied to an appropriate logic level to prevent false triggering.
The TLC556C is characterized for operation from 0°C to 70°C. The TLC556I is characterized for operation from
– 40°C to 85°C. The TLC556M is characterized for operation over the full military temperature range of – 55°C
to 125°C.
LinCMOS is a trademark of Texas Instruments Incorporated.
Copyright 1997, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
AVAILABLE OPTIONS
PACKAGE
TA
RANGE
VDD
RANGE
O°C
to
70°C
2V
to
18 V
TLC556CD
TLC556CN
– 4O°C
to
85°C
3V
to
18 V
TLC556lD
TLC556IN
– 55°C
to
125°C
5V
to
18 V
TLC556MD
SMALL OUTLINE
(D)
CHIP CARRIER
(FK)
CERAMIC DIP
(J)
TLC556MFK
PLASTIC DIP
(N)
TLC556MJ
CHIP FORM
(Y)
TLC556Y
TLC556MN
The D package is available taped and reeled. Add the suffix R to the device type (e.g., TLC556CDR).
FUNCTION TABLE
RESET
VOLTAGE†
TRIGGER
VOLTAGE†
THRESHOLD
VOLTAGE†
OUTPUT
DISCHARGE
SWITCH
On
< MIN
Irrelevant
Irrelevant
L
> MAX
< MIN
Irrelevant
H
Off
>MAX
>MAX
>MAX
L
On
> MAX
> MAX
< MIN
As previously established
† For conditions shown as MIN or MAX, use the appropriate value specified under electrical characteristics.
functional block diagram (each timer)
VDD
14
CONT
3
RESET
4
R
THRES
R1
2
R 1
5
OUT
S
R
6
TRIG
R
1
DISCH
7
GND
RESET can override TRIG and THRES.
TRIG can override THRES.
Pin numbers shown are for the D, J, or N packages.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
TLC556Y chip information
These chips, properly assembled, display characteristics similar to the TLC556 (see electrical table). Thermal
compression or ultrasonic bonding may be used on the doped aluminum bonding pads. Chips may be mounted
with conductive epoxy or a gold-silicon preform.
BONDING PAD ASSIGNMENTS
CHIP THICKNESS: 15 TYPICAL
BONDING PADS: 4 × 4 MINIMUM
TJ max = 150°C
TOLERANCES ARE ± 10%
61
ALL DIMENSIONS ARE IN MILS
NO BACKSIDE METALLIZATION
PIN (7) INTERNALLY CONNECTED
TO BACKSIDE OF CHIP
97
FUNCTIONAL BLOCK DIAGRAM (EACH TIMER)
VDD
(14)
CONT
(3)
RESET
(4)
R
THRESH
R1
(2)
R 1
(5)
OUT
S
R
(6)
TRIG
R
(1)
DISCH
(7)
GND
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
TLC556C
TLC556I
TLC556M
UNIT
18
18
18
V
– 0.3 to VDD
– 0.3 to VDD
– 0.3 to VDD
V
Sink current, discharge or output
150
150
150
mA
Source current, output
15
15
15
mA
Supply voltage, VDD (see Note 1)
Input voltage range, VI
Continuous total power dissipation
See Dissipation Rating Table
Operating free-air temperature range
Storage temperature range
Case temperature for 60 seconds
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
FK package
J package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
D or N package
0 to 70
– 40 to 85
– 55 to 125
°C
– 65 to 150
– 65 to 150
– 65 to 150
°C
260
300
°C
260
260
NOTE 1: All voltage values are with respect to network ground terminal.
DISSIPATION RATING TABLE
PACKAGE
D
FK
J
N
TA ≤ 25°C
POWER RATING
950 mW
1375 mW
1375 mW
1150 mW
DERATING FACTOR
ABOVE TA = 25°C
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING
7.6 mW/°C
11.0 mW/°C
11.0 mW/°C
9.2 mW/°C
608 mW
880 mW
880 mW
736 mW
494 mW
715 mW
715 mW
598 mW
N/A
275 mW
275 mW
N/A
recommended operating conditions
Supply voltage, VDD
TLC556C
Operating free-air temperature range, TA
4
MIN
MAX
2
15
0
70
TLC556I
– 40
85
TLC556M
– 55
125
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
V
°C
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
electrical characteristics at specified free-air temperature, VDD = 2 V for TLC556C, VDD = 3 V for
TLC556I
PARAMETER
VIT
TEST
CONDITIONS
Input threshold voltage
Trigger voltage
I(trigger)
(t i
)
Trigger current
V((reset)
t)
Reset voltage
I(reset)
(
t)
Reset current
TYP
MAX
MIN
TYP
MAX
25°C
0.95
1.33
1.65
1.6
2
2.4
Full range
0.85
1.75
1.5
IOL = 1 mA
VOH
High level output voltage
High-level
IOH = –300
300 µA
VOL
Low level output voltage
Low-level
IOL = 1 mA
IDD
Supply current
See Note 2
10
10
MAX
75
150
0.4
Full range
0.3
0.67
0.95
0.71
1.05
0.61
1
10
10
MAX
75
150
25°C
0.4
0.3
1.1
1.5
0.4
1.8
0.3
1.1
10
10
MAX
75
150
MAX
66.7%
66.7%
25°C
0.04
Full range
0.2
0.03
0.25
0.1
0.1
MAX
0.5
120
25°C
1.5
1.5
25°C
1.9
Full range
1.5
0.07
0.2
0.3
0.07
130
500
800
V
V
0.3
0.4
130
V
nA
1.9
0.35
V
pA
2.5
Full range
25°C
1.5
V
pA
0.375
25°C
Full range
1.29
1.8
25°C
UNIT
pA
1.39
25°C
Full range
Discharge
g switch off-state current
2.5
25°C
25°C
Control voltage (open circuit) as
a percentage of supply voltage
Discharge
g switch on-state voltage
TLC556I
MIN
Threshold current
V(t
i
)
(trigger)
TLC556C
TA†
500
1000
V
µA
† Full range is 0°C to 70°C for TLC556C and – 40°C to 85°C for TLC556I.
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or TRIG.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
electrical characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
VIT
TEST
CONDITIONS
Input threshold
voltage
Threshold current
V((trigger))
Trigger voltage
I((trigger)
i
)
Trigger current
V((reset))
Reset voltage
I((reset))
Reset current
Control voltage (open
circuit) as a
percentage of supply
voltage
Discharge
g switch
on-state voltage
IOL
O = 10 mA
Discharge
g switch
off-state current
VO
OH
High-level
g
output
voltage
IOH
1 mA
O = –1
IOL
O = 8 mA
VO
OL
Low-level output
voltage
IOL
O = 5 mA
IOL
3 2 mA
O = 3.2
IDD
Supply current
See Note 2
TLC556C
TLC556I
TLC556M
TA†
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
25°C
2.8
3.3
3.8
2.8
3.3
3.8
2.8
3.3
3.8
Full range
2.7
3.9
2.7
3.9
2.7
25°C
10
10
10
MAX
75
150
5000
25°C
1.36
Full range
1.26
1.66
1.96
1.36
2.06
1.26
1.66
1.96
1.36
2.06
1.26
1.66
10
10
10
MAX
75
150
5000
25°C
0.4
Full range
0.3
1.1
1.5
0.4
1.8
0.3
1.1
1.5
0.4
1.8
0.3
1.1
10
10
10
MAX
75
150
5000
MAX
66.7%
66.7%
66.7%
25°C
0.15
Full range
0.5
0.15
0.6
0.5
0.15
0.6
0.6
25°C
0.1
0.1
0.1
MAX
0.5
2
120
25°C
4.1
Full range
4.1
25°C
4.8
0.21
0.13
Full range
0.4
0.21
0.3
0.08
0.3
0.13
700
1000
0.4
0.3
0.08
0.3
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
0.21
pA
0.5
V
nA
700
1200
0.4
0.6
0.13
0.3
0.45
0.08
0.3
340
700
0.35
340
V
V
0.4
0.35
340
1.5
4.8
0.5
0.4
Full range
25°C
4.1
V
pA
4.1
0.5
Full range
25°C
4.8
4.1
Full range
25°C
4.1
1.96
1.8
25°C
V
pA
2.06
25°C
† Full range is 0°C to 70°C for TLC556C, – 40°C to 85°C for TLC556I, and – 55°C to 125°C for TLC556M.
NOTE 2:
These values apply for the expected operating configurations in which THRES is connected directly to DISCH or to TRIG.
6
3.9
UNIT
V
0.4
1400
µA
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
electrical characteristics at specified free-air temperature, VDD = 15 V
PARAMETER
VIT
TEST
CONDITIONS
Input threshold voltage
Threshold current
V(t
(trigger)
i
)
Trigger voltage
I(trigger)
(t i
)
Trigger current
V((reset)
t)
Reset voltage
I(reset)
(
t)
Reset current
Control voltage (open
circuit) as a percentage of supply voltage
Discharge
g switch onstate voltage
IOL = 100 mA
Discharge
g switch offstate current
IOH = –10
10 mA
VOH
High-level
g
output
voltage
IOH = –5
5 mA
IOH = –1
1 mA
IOL = 100 mA
VOL
Low-level output
voltage
IOL = 50 mA
IOL = 10 mA
IDD
Supply current
See Note 2
TA†
TLC556C
TLC556I
TLC556M
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
25°C
9.45
10
10.55
9.45
10
10.55
9.45
10
10.55
Full range
9.35
10.65
9.35
10.65
9.35
10
10
10
MAX
75
150
5000
25°C
4.65
4.55
5
5.35
4.65
5.45
4.55
5
5.35
4.65
5.45
4.55
5
10
10
10
MAX
75
150
5000
25°C
0.4
0.3
1.1
1.5
0.4
1.8
0.3
1.1
1.5
0.4
1.8
0.3
1.1
10
10
10
MAX
75
150
5000
MAX
66.7%
66.7%
66.7%
25°C
0.8
1.7
0.8
1.8
1.7
0.8
1.8
0.1
0.1
0.1
MAX
0.5
2
120
25°C
12.5
12.5
25°C
13.5
Full range
13.5
25°C
14.2
Full range
14.2
25°C
14.2
14.6
25°C
13.5
14.9
14.2
1.28
3.2
14.6
1
13.5
14.9
0.3
1.28
1.2
1.6
pA
1.7
V
nA
14.2
14.6
14.2
V
14.9
3.2
1.28
3.7
0.63
1
0.12
0.3
0.63
1.2
1.8
1
V
1.5
0.12
0.4
0.72
3.2
3.8
1.4
0.4
0.72
V
14.2
1.3
0.12
1.5
13.5
3.6
0.63
pA
12.5
14.2
Full range
Full range
12.5
13.5
Full range
25°C
14.2
12.5
Full range
25°C
12.5
V
1.8
25°C
Full range
5.35
1.8
25°C
Full range
pA
5.45
25°C
Full range
V
10.65
25°C
Full range
UNIT
0.3
0.45
0.72
1.2
mA
2
† Full range is 0°C to 70°C for TLC556C, – 40°C to 85°C for TLC556I, and – 55°C to 125°C for TLC556M.
NOTE 2:
These values apply for the expected operating configurations in which THRES is connected directly to DISCH or TRIG.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
electrical characteristics, VDD = 5 V, TA = 25°C
PARAMETER
VIT
TEST CONDITIONS
Input threshold voltage
MIN
TYP
MAX
2.8
3.3
3.8
1.36
1.66
0.4
1.1
Threshold current
V(trigger)
Trigger voltage
I(trigger)
Trigger current
V(reset)
I(reset)
Reset voltage
10
IOL = 10 mA
0.15
Discharge switch off-state current
VOH
VOL
IOH = – 1 mA
IOL = 8 mA
Low-level output voltage
4.1
IOL = 5 mA
IOL = 2.1 mA
V
pA
0.5
0.1
High-level output voltage
V
pA
1.5
10
Discharge switch on-state voltage
V
pA
1.96
10
Reset current
UNIT
V
nA
4.8
V
0.21
0.4
0.13
0.3
0.08
0.3
IDD
Supply current
See Note 2
3.40
700
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or TRIG.
V
µA
operating characteristics, VDD = 5 V, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
Initial error of timing interval †
VDD = 5 V to 15 V,
Supply voltage sensitivity of timing interval
CT = 0.1 µF,
tr
tf
Output pulse rise time
fmax
Maximum frequency in astable mode
Output pulse fall time
TYP
MAX
RA = RB = 1 kΩ to 100 kΩ
1%
3%
See Note 3
0.1
0.5
20
75
15
60
RL = 10 MΩ,
MΩ
CL = 10 pF
RA = 470 Ω,
CT = 200 pF,
RB = 200 Ω,
See Note 3
MIN
1.2
2.1
UNIT
%/V
ns
MHz
† Timing interval error is defined as the difference between the measured value and the average value of a random sample from each process
run.
NOTE 3: RA, RB, and CT are as defined in Figure 3.
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
TYPICAL CHARACTERISTICS
PROPAGATION DELAY TIMES (TO DISCHARGE
OUTPUT FROM TRIGGER AND THRESHOLD
SHORTED TOGETHER)
vs
SUPPLY VOLTAGE
DISCHARGE SWITCH ON-STATE RESISTANCE
vs
FREE-AIR TEMPERATURE
600
Discharge Switch On-State Resistance – Ω
70
VDD = 2 V, IO = 1 mA
40
VDD = 5 V, IO = 10 mA
20
VDD = 15 V, IO = 100 mA
10
7
4
2
1
–75
t PHL , t PLH – Propagation Delay Times – ns
100
IO(on) ≥ 1 mA
CL ≈ 0
TA = 25°C
500
400
300
tPHL
200
tPLH‡
100
0
–50
–25
0
25
50
75
100
125
0
2
TA – Free-Air Temperature – °C
4
6
8
10
12
14 16
18 20
VDD – Supply Voltage – V
‡ The effects of the load resistance on these values must be
taken into account separately.
Figure 1
Figure 2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
APPLICATION INFORMATION
0.1 µF
RA
tL
tH
VDD
0.1 µF
tPHL
CONT
VDD
RESET
TLC556
DISCH
RL
2/3 VDD
Output
OUT
RB
THRES
CL
1/3 VDD
TRIG
GND
GND
CT
tPLH
CIRCUIT
TRIGGER AND THRESHOLD VOLTAGE WAVEFORM
Figure 3. Astable Operation
Connecting the trigger input to the threshold input, as shown in Figure 3, causes the timer to run as a
multivibrator. The capacitor CT charges through RA and RB to the threshold voltage level (approximately 0.67
VDD) and then discharges through RB only to the value of the trigger voltage level (approximately 0.33 VDD).
The output is high during the charging cycle (tH) and low during the discharge cycle (tL). The duty cycle is
controlled by the values of RA, and RB, and CT, as shown in the equations below.
[ CT (RA ) RB) In 2 (In 2 + 0.693)
t L [ C T R B In 2
Period + t H ) t L [ C T (R A ) 2R B) In 2
tL
RB
Output driver duty cycle +
[
1 *
tH ) tL
R A ) 2R B
tH
Output waveform duty cycle
+ tH t)H tL [ R )RB2R
B
A
The 0.1-µF capacitor at CONT in Figure 3 decreases the period by about 10%.
The formulas shown above do not allow for any propagation delay from the trigger and threshold inputs to the
discharge output. These delay times add directly to the period and create differences between calculated and
actual values that increase with frequency. In addition, the discharge output resistance ron adds to RB to provide
another source of error in the calculation when RB is very low or ron is very high.
ƪ ǒ
ƪ ǒ
Ǔƫ
Ǔƫ
The equations below provide better agreement with measured values.
10
tH
+ CT (RA ) RB) In
tL
+ CT (RB ) ron) In
3
* exp
* tPLH
C T (R B ) r on)
3
* exp
* tPHL
C T (R A ) R B)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
) tPHL
) tPLH
TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
APPLICATION INFORMATION
The preceding equations and those given earlier are similar in that a time constant is multiplied by the logarithm
of a number or function. The limit values of the logarithmic terms must be between In 2 at low frequencies and
In 3 at extremely high frequencies. For a duty cycle close to 50%, an appropriate constant for the logarithmic
t
t
H
terms can be substituted with good results. Duty cycles less than 50%
will require that H < 1 and
t
t
t
H
L
L
possibly RA ≤ ron. These conditions can be difficult to obtain.
)
In monostable applications, the trip point of the trigger input can be set by a voltage applied to CONT. An input
voltage between 10% and 80% of the supply voltage from a resistor divider with at least 500-µA bias provides
good results.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
PACKAGE OPTION ADDENDUM
www.ti.com
10-Jun-2022
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
Samples
(4/5)
(6)
5962-89503022A
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
596289503022A
TLC556MFKB
5962-8950302CA
ACTIVE
CDIP
J
14
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
5962-8950302CA
TLC556MJB
Samples
TLC556CD
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
TLC556C
Samples
TLC556CDG4
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
0 to 70
TLC556C
Samples
TLC556CDR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556C
Samples
TLC556CDRG4
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556C
Samples
TLC556CN
ACTIVE
PDIP
N
14
25
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC556CN
Samples
TLC556ID
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556I
Samples
TLC556IDG4
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556I
Samples
TLC556IDR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
TLC556I
Samples
TLC556IDRG4
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-40 to 85
TLC556I
Samples
TLC556IN
ACTIVE
PDIP
N
14
25
RoHS & Green
NIPDAU
N / A for Pkg Type
TLC556IN
Samples
TLC556MD
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556M
Samples
TLC556MDG4
ACTIVE
SOIC
D
14
50
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
TLC556M
Samples
TLC556MDR
ACTIVE
SOIC
D
14
2500
RoHS & Green
NIPDAU
Level-1-260C-UNLIM
-55 to 125
TLC556M
Samples
TLC556MFKB
ACTIVE
LCCC
FK
20
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
596289503022A
TLC556MFKB
TLC556MJ
ACTIVE
CDIP
J
14
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
TLC556MJ
Samples
TLC556MJB
ACTIVE
CDIP
J
14
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
5962-8950302CA
TLC556MJB
Samples
Addendum-Page 1
-55 to 125
Samples
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
10-Jun-2022
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of