0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TLV2548EVM

TLV2548EVM

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    -

  • 描述:

    EVALUATION MODULE FOR TLV2548

  • 数据手册
  • 价格&库存
TLV2548EVM 数据手册
                                SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 D Maximum Throughput 200-KSPS D Built-In Reference, Conversion Clock and 8× FIFO D Differential/Integral Nonlinearity Error: D D D ±1 LSB Signal-to-Noise and Distortion Ratio: 70 dB, fi = 12-kHz Spurious Free Dynamic Range: 75 dB, fi = 12- kHz SPI (CPOL = 0, CPHA = 0)/DSP-Compatible Serial Interfaces With SCLK up to 20-MHz TLV2548 DW OR PW PACKAGE (TOP VIEW) SDO SDI SCLK EOC/(INT) VCC A0 A1 A2 A3 A4 1 20 2 19 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 CS REFP REFM FS PWDN GND CSTART A7 A6 A5 D Single Wide Range Supply 2.7 Vdc to D D D D D 5.5 Vdc Analog Input Range 0-V to Supply Voltage With 500 kHz BW Hardware Controlled and Programmable Sampling Period Low Operating Current (1.0-mA at 3.3-V, 1.1-mA at 5.5-V With External Ref Power Down: Software/Hardware Power-Down Mode (1 µA Max, Ext Ref), Autopower-Down Mode (1 µA, Ext Ref) Programmable Auto-Channel Sweep TLV2544 D OR PW PACKAGE (TOP VIEW) SDO SDI SCLK EOC/(INT) VCC A0 A1 A2 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 CS REFP REFM FS PWDN GND CSTART A3 description The TLV2548 and TLV2544 are a family of high performance, 12-bit low power, 3.86 µs, CMOS analog-to-digital converters (ADC) which operate from a single 2.7-V to 5.5-V power supply. These devices have three digital inputs and a 3-state output [chip select (CS), serial input-output clock (SCLK), serial data input (SDI), and serial data output (SDO)] that provide a direct 4-wire interface to the serial port of most popular host microprocessors (SPI interface). When interfaced with a TI DSP, a frame sync (FS) signal is used to indicate the start of a serial data frame. In addition to a high-speed A/D converter and versatile control capability, these devices have an on-chip analog multiplexer that can select any analog inputs or one of three internal self-test voltages. The sample-and-hold function is automatically started after the fourth SCLK edge (normal sampling) or can be controlled by a special pin, CSTART, to extend the sampling period (extended sampling). The normal sampling period can also be programmed as short (12 SCLKs) or as long (24 SCLKs) to accommodate faster SCLK operation popular among high-performance signal processors. The TLV2548 and TLV2544 are designed to operate with very low power consumption. The power-saving feature is further enhanced with software/hardware/autopower-down modes and programmable conversion speeds. The conversion clock (OSC) and reference are built-in. The converter can use the external SCLK as the source of the conversion clock to achieve higher (up to 2.8 µs when a 20 MHz SCLK is used) conversion speed. Two different internal reference voltages are available. An optional external reference can also be used to achieve maximum flexibility. The TLV2544C and the TLV2548C are characterized for operation from 0°C to 70°C. The TLV2544I and the TLV2548I are characterized for operation from − 40°C to 85°C. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright  1999 − 2003, Texas Instruments Incorporated     !"#$%&'#! ( )*$$+!' &( #" ,*-.)&'#! /&'+ $#/*)'( )#!"#$% '# (,+)")&'#!( ,+$ '0+ '+$%( #" +1&( !('$*%+!'( ('&!/&$/ 2&$$&!'3 $#/*)'#! ,$#)+((!4 /#+( !#' !+)+((&$.3 !).*/+ '+('!4 #" &.. ,&$&%+'+$( ! ,$#/*)'( )#%,.&!' '# 5 6 77 &.. ,&$&%+'+$( &$+ '+('+/ *!.+(( #'0+$2(+ !#'+/ ! &.. #'0+$ ,$#/*)'( ,$#/*)'#! ,$#)+((!4 /#+( !#' !+)+((&$.3 !).*/+ '+('!4 #" &.. ,&$&%+'+$( POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 functional block diagram VCC REFP REFM 2544 A0 X A1 X A2 X A3 X FIFO 12 Bit × 8 Analog MUX 2548 A0 A1 A2 A3 A4 A5 A6 A7 4/2 V Reference Low Power 12-BIT SAR ADC S/H OSC INT Command Decode Conversion Clock EXT CFR SDI M U X SDO CMR (4 MSBs) DIV SCLK CS FS CSTART PWDN Control Logic EOC/(INT) GND AVAILABLE OPTIONS PACKAGED DEVICES TA 2 20-TSSOP (PW) 20-SOIC (DW) 16-SOIC (D) 16-TSSOP (PW) 20-CDIP (J) 20-LCCC (FK) 0°C to 70°C TLV2548CPW TLV2548CDW TLV2544CD TLV2544CPW — — −40°C to 85°C TLV2548IPW TLV2548IDW TLV2544ID TLV2544IPW — — POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 Terminal Functions TERMINAL NO. I/O DESCRIPTION 6 7 8 9 10 11 12 13 I Analog signal inputs. The analog inputs are applied to these terminals and are internally multiplexed. The driving source impedance should be less than or equal to 1 kΩ. 16 20 I Chip select. A high-to-low transition on the CS input resets the internal 4-bit counter, enables SDI, and removes SDO from 3-state within a maximum setup time. SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first. NOTE: CS falling and rising edges need to happen when SCLK is low for a microprocessor interface such as SPI. CSTART 10 14 I This terminal controls the start of sampling of the analog input from a selected multiplex channel. Sampling time starts with the falling edge of CSTART and ends with the rising edge of CSTART as long as CS is held high. In mode 01, select cycle, CSTART can be issued as soon as CHANNEL is selected which means the fifth SCLK during the select cycle, but the effective sampling time is not started until CS goes to high. The rising edge of CSTART (when CS = 1) also starts the conversion. Tie this terminal to VCC if not used. EOC/(INT) 4 4 O End of conversion or interrupt to host processor. [PROGRAMMED AS EOC]: This output goes from a high-to-low logic level at the end of the sampling period and remains low until the conversion is complete and data are ready for transfer. EOC is used in conversion mode 00 only. NAME TLV2544 TLV2548 6 7 8 9 CS A0 A1 A2 A3 A0 A1 A2 A3 A4 A5 A6 A7 For a source impedance greater than 1 kΩ, use the asynchronous conversion start signal CSTART (CSTART low time controls the sampling period) or program long sampling period to increase the sampling time. [PROGRAMMED AS INT]: This pin can also be programmed as an interrupt output signal to the host processor. The falling edge of INT indicates data are ready for output. The following CS↓ or FS clears INT. FS 13 17 I DSP frame sync input. Indication of the start of a serial data frame in or out of the device. If FS remains low after the falling edge of CS, SDI is not enabled until an active FS is presented. A high-to-low transition on the FS input resets the internal 4-bit counter and enables SDI within a maximum setup time. SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first. GND 11 15 I Ground return for the internal circuitry. Unless otherwise noted, all voltage measurements are with respect to GND. PWDN 12 16 I Both analog and reference circuits are powered down when this pin is at logic zero. The device can be restarted by active CS, FS or CSTART after this pin is pulled back to logic one. SCLK 3 3 I Input serial clock. This terminal receives the serial SCLK from the host processor. SCLK is used to clock the input SDI to the input register. When programmed, it may also be used as the source of the conversion clock. NOTE: This device supports CPOL (clock polarity) = 0, which is SCLK returns to zero when idling for SPI compatible interface. SDI 2 2 I Serial data input. The input data is presented with the MSB (D15) first. The first 4-bit MSBs, D(15−12) are decoded as one of the 16 commands (12 only for the TLV2544). The configure write commands require an additional 12 bits of data. When FS is not used (FS =1), the first MSB (D15) is expected after the falling edge of CS and is latched in on the rising edges of SCLK (after CS↓). When FS is used (typical with an active FS from a DSP) the first MSB (D15) is expected after the falling edge of FS and is latched in on the falling edges of SCLK. SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first. Tie this terminal to VCC if not used. See the date code information section, item (1). POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 Terminal Functions (Continued) TERMINAL NAME SDO NO. TLV2544 TLV2548 1 1 I/O DESCRIPTION O The 3-state serial output for the A/D conversion result. SDO is kept in the high-impedance state when CS is high and after the CS falling edge and until the MSB is presented. The output format is MSB first. When FS is not used (FS = 1 at the falling edge of CS), the MSB is presented to the SDO pin after the CS falling edge, and successive data are available at the rising edge of SCLK and changed on the falling edge. When FS is used (FS = 0 at the falling edge of CS), the MSB is presented to SDO after the falling edge of CS and FS = 0 is detected. Successive data are available at the falling edge of SCLK and changed on the rising edge. (This is typically used with an active FS from a DSP.) For conversion and FIFO read cycles, the first 12 bits are result from previous conversion (data) followed by 4 don’t care bits. The first four bits from SDO for CFR read cycles should be ignored. The register content is in the last 12 bits. SDO is 3-state (float) after the 16th bit. See the date code information section, item (2). REFM 14 18 I External reference input or internal reference decoupling. Tie this pin to analog ground if internal reference is used. REFP 15 19 I External reference input or internal reference decoupling. (Shunt capacitors of 10 µF and 0.1 µF between REFP and REFM.) The maximum input voltage range is determined by the difference between the voltage applied to this terminal and the REFM terminal when an external reference is used. VCC 5 5 I Positive supply voltage detailed description analog inputs and internal test voltages The 4/8 analog inputs and three internal test inputs are selected by the analog multiplexer depending on the command entered. The input multiplexer is a break-before-make type to reduce input-to-input noise injection resulting from channel switching. converter The TLV2544/48 uses a 12-bit successive approximation ADC utilizing a charge redistribution DAC. Figure 1 shows a simplified version of the ADC. The sampling capacitor acquires the signal on Ain during the sampling period. When the conversion process starts, the SAR control logic and charge redistribution DAC are used to add and subtract fixed amounts of charge from the sampling capacitor to bring the comparator into a balanced condition. When the comparator is balanced, the conversion is complete and the ADC output code is generated. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 detailed description (continued) Charge Redistribution DAC _ Ain + Control Logic ADC Code REFM Figure 1. Simplified Model of the Successive-Approximation System serial interface INPUT DATA FORMAT MSB LSB D15−D12 D11−D0 Command ID[15:12] Configuration data field ID[11:0] Input data is binary. All trailing blanks can be filled with zeros. OUTPUT DATA FORMAT READ CFR/FIFO READ MSB LSB D15−D12 Don’t care D11−D0 Register content or FIFO content OD[11:0] OUTPUT DATA FORMAT CONVERSION MSB LSB D15−D4 D3−D0 Conversion result OD[11:0] Don’t care The output data format is binary (unipolar straight binary). binary Zero scale code = 000h, Vcode = VREFM Full scale code = FFFh, Vcode = VREFP − 1 LSB POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 control and timing power up and initialization requirements D Determine processor type by writing A000h to the TLV2544/48 (CS must be toggled) D Configure the device (CS must make a high-to-low transition, then can be held low if in DSP mode; i.e., active FS.) The first conversion after power up or resuming from power down is not valid. start of the cycle: D When FS is not used (FS = 1 at the falling edge of CS), the falling edge of CS is the start of the cycle. D When FS is used (FS is an active signal from a DSP), the falling edge of FS is the start of the cycle. first 4-MSBs: the command register (CMR) The TLV2544/TLV2548 have a 4-bit command set (see Table 1) plus a 12-bit configuration data field. Most of the commands require only the first 4 MSBs, i.e., without the 12-bit data field. The valid commands are listed in Table 1. Table 1. TLV2544/TLV2548 Command Set SDI D(15−12) BINARY TLV2548 COMMAND TLV2544 COMMAND 0000b 0h Select analog input channel 0 Select analog input channel 0 0001b 1h Select analog input channel 1 N/A 0010b 2h Select analog input channel 2 Select analog input channel 1 0011b 3h Select analog input channel 3 N/A 0100b 4h Select analog input channel 4 Select analog input channel 2 0101b 5h Select analog input channel 5 N/A 0110b 6h Select analog input channel 6 Select analog input channel 3 0111b 7h Select analog input channel 7 N/A 1000b 8h SW power down (analog + reference) 1001b 9h Read CFR register data shown as SDO D(11−0) 1010b Ah plus data 1011b Bh Select test, voltage = (REFP+REFM)/2 1100b Ch Select test, voltage = REFM 1101b Dh Select test, voltage = REFP 1110b Eh FIFO read, FIFO contents shown as SDO D(15−4), D(3−0) = 0000 Write CFR followed by 12-bit data, e.g., 0A100h means external reference, short sampling, SCLK/4, single shot, INT 1111b Fh plus data Reserved NOTE: The status of the CFR can be read with a read CFR command when the device is programmed for one-shot conversion mode (CFR D[6,5] = 00). 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 control and timing (continued) configuration Configuration data is stored in one 12-bit configuration register (CFR) (see Table 2 for CFR bit definitions). Once configured after first power up, the information is retained in the H/W or S/W power down state. When the device is being configured, a write CFR cycle is issued by the host processor. This is a 16-bit write. If the SCLK stops after the first 8 bits are entered, then the next eight bits can be taken after the SCLK is resumed. Table 2. TLV2544/TLV2548 Configuration Register (CFR) Bit Definitions BIT DEFINITION D11 Reference select 0: External 1: Internal (Tie REFM to analog ground if the Internal reference is selected.) D10 Internal reference voltage select 0: Internal ref = 4 V 1: internal ref = 2 V D9 Sample period select 0: Short sampling 12 SCLKs (1x sampling time) 1: Long sampling 24 SCLKs (2x sampling time) D(8,7) Conversion clock source select 00: Conversion clock = internal OSC 01: Conversion clock = SCLK 10: Conversion clock = SCLK/4 11: Conversion clock = SCLK/2 D(6,5) Conversion mode select 00: Single shot mode [FIFO not used, D(1,0) has no effect.] 01: Repeat mode 10: Sweep mode 11: Repeat sweep mode D(4,3)† TLV2548 Sweep auto sequence select 00: 0−1−2−3−4−5−6−7 01: 0−2−4−6−0−2−4−6 10: 0−0−2−2−4−4−6−6 11: 0−2−0−2−0−2−0−2 TLV2544 Sweep auto sequence select 00: N/A 01: 0−1−2−3−0−1−2−3 10: 0−0−1−1−2−2−3−3 11: 0−1−0−1−0−1−0−1 D2 EOC/INT − pin function select 0: Pin used as INT 1: Pin used as EOC D(1,0) FIFO trigger level (sweep sequence length) 00: Full (INT generated after FIFO level 7 filled) 01: 3/4 (INT generated after FIFO level 5 filled) 10: 1/2 (INT generated after FIFO level 3 filled) 11: 1/4 (INT generated after FIFO level 1 filled) † These bits only take effect in conversion modes 10 and 11. sampling The sampling period starts after the first 4 input data are shifted in if they are decoded as one of the conversion commands. These are select analog input (channel 0 through 7) and select test (channel 1 through 3). POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 normal sampling When the converter is using normal sampling, the sampling period is programmable. It can be 12 SCLKs (short sampling) or 24 SCLKs (long sampling). Long sampling helps when SCLK is faster than 10 MHz or when input source resistance is high. extended sampling CSTART − An asynchronous (to the SCLK) signal, via dedicated hardware pin, CSTART, can be used in order to have total control of the sampling period and the start of a conversion. This extended sampling is user-defined and is totally independent of SCLK. While CS is high, the falling edge of CSTART is the start of the sampling period and is controlled by the low time of CSTART. The minimum low time for CSTART should be at least equal to the minimum t(SAMPLE). In a select cycle used in mode 01 (REPEAT MODE), CSTART can be started as soon as the channel is selected (after the fifth SCLK). In this case the sampling period is not started until CS has become inactive. Therefore the nonoverlapped CSTART low time must meet the minimum sampling time requirement. The low-to-high transition of CSTART terminates the sampling period and starts the conversion period. The conversion clock can also be configured to use either internal OSC or external SCLK. This function is useful for an application that requires: D The use of an extended sampling period to accommodate different input source impedance D The use of a faster I/O clock on the serial port but not enough sampling time is available due to the fixed number of SCLKs. This could be due to a high input source impedance or due to higher MUX ON resistance at lower supply voltage. Once the conversion is complete, the processor can initiate a read cycle by using either the read FIFO command to read the conversion result or by simply selecting the next channel number for conversion. Since the device has a valid conversion result in the output buffer, the conversion result is simply presented at the serial data output. To completely get out of the extended sampling mode, CS must be toggled twice from a high-to-low transition while CSTART is high. The read cycle mentioned above followed by another configuration cycle of the ADC qualifies this condition and successfully puts the ADC back to its normal sampling mode. This can be viewed in Figure 9. Table 3. Sample and Convert Conditions CSTART CONDITIONS SAMPLE CS = 1 (see Figures 11 and 18) No sampling clock (SCLK) required. Sampling period is totally controlled by the low time of CSTART. The high-to-low transition of CSTART (when CS=1) starts the sampling of the analog input signal. The low time of CSTART dictates the sampling period. The low-to-high transition of CSTART ends sampling period and begins the conversion cycle. (Note: this trigger only works when internal reference is selected for conversion modes 01, 10, and 11.) CS CSTART = 1 FS = 1 FS CSTART = 1 CS = 0 8 CONVERT 1) If the internal clock OSC is selected a maximum SCLK is required. Sampling period is programmable conversion time of 3.86 µs can be achieved. under normal sampling. When programmed to sample 2) If external SCLK is selected, conversion time is under short sampling, 12 SCLKs are generated to tconv = 14 × DIV/f(SCLK), where DIV can be 1, 2, or complete sampling period. 24 SCLKs are generated 4. when programmed for long sampling. A command set to configure the device requires 4 SCLKs thereby extending to 16 or 28 SCLKs respectively before conversion takes place. (Note: Because the ADC only bypasses a valid channel select command, the user can use select channel 0, 0000b, as the SDI input when either CS or FS is used as trigger for conversion. The ADC responds to commands such as SW powerdown, 1000b.) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TLV2544/TLV2548 conversion modes The TLV2544 and TLV2548 have four different conversion modes (mode 00, 01, 10, 11). The operation of each mode is slightly different, depending on how the converter performs the sampling and which host interface is used. The trigger for a conversion can be an active CSTART (extended sampling), CS (normal sampling, SPI interface), or FS (normal sampling, TMS320 DSP interface). When FS is used as the trigger, CS can be held active, i.e. CS does not need to be toggled through the trigger sequence. SDI can be one of the channel select commands, such as SELECT CHANNEL 0. Different types of triggers should not be mixed throughout the repeat and sweep operations. When CSTART is used as the trigger, the conversion starts on the rising edge of CSTART. The minimum low time for CSTART is equal to t(SAMPLE). If an active CS or FS is used as the trigger, the conversion is started after the 16th or 28th SCLK edge. Enough time (for conversion) should be allowed between consecutive triggers so that no conversion is terminated prematurely. one shot mode (mode 00) One shot mode (mode 00) does not use the FIFO, and the EOC is generated as the conversion is in progress (or INT is generated after the conversion is done). repeat mode (mode 01) Repeat mode (mode 01) uses the FIFO. This mode setup requires configuration cycle and channel select cycle. Once the programmed FIFO threshold is reached, the FIFO must be read, or the data is lost when the sequence starts over again with the SELECT cycle and series of triggers. No configuration is required except for reselecting the channel unless the operation mode is changed. This allows the host to set up the converter and continue monitoring a fixed input and come back to get a set of samples when preferred. Triggered by CSTART: The first conversion can be started with a select cycle or CSTART. To do so, the user can issue CSTART during the select cycle, immediately after the four-bit channel select command. The first sample started as soon as the select cycle is finished (i.e., CS returns to 1). If there is enough time (2 µs) left between the SELECT cycle and the following CSTART, a conversion is carried out. In this case, you need one less trigger to fill the FIFO. Succeeding samples are triggered by CSTART. sweep mode (mode 10) Sweep mode (mode 10) also uses the FIFO. Once it is programmed in this mode, all of the channels listed in the selected sweep sequence are visited in sequence. The results are converted and stored in the FIFO. This sweep sequence may not be completed if the FIFO threshold is reached before the list is completed. This allows the system designer to change the sweep sequence length. Once the FIFO has reached its programmed threshold, an interrupt (INT) is generated. The host must issue a read FIFO command to read and clear the FIFO before the next sweep can start. repeat sweep mode (mode 11) Repeat sweep mode (mode 11) works the same way as mode 10 except the operation has an option to continue even if the FIFO threshold is reached. Once the FIFO has reached its programmed threshold, an interrupt (INT) is generated. Then two things may happen: 1. The host may choose to act on it (read the FIFO) or ignore it. If the next cycle is a read FIFO cycle, all of the data stored in the FIFO is retained until it has been read in order. 2. If the next cycle is not a read FIFO cycle, or another CSTART is generated, all of the content stored in the FIFO is cleared before the next conversion result is stored in the FIFO, and the sweep is continued. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TLV2544/TLV2548 conversion modes (continued) Table 4. TLV2544/TLV2548 Conversion Mode CONVERSION MODE One shot Repeat Sweep Repeat sweep CFR D(6,5) 00 01 10 11 SAMPLING TYPE OPERATION Normal • • • • Single conversion from a selected channel CS or FS to start select/sampling/conversion/read One INT or EOC generated after each conversion Host must serve INT by selecting channel, and converting and reading the previous output. Extended • • • • • Single conversion from a selected channel CS to select/read CSTART to start sampling and conversion One INT or EOC generated after each conversion Host must serve INT by selecting next channel and reading the previous output. Normal • • • • Repeated conversions from a selected channel CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by either 1) (FIFO read) reading out all of the FIFO contents up to the threshold, then repeat conversions from the same selected channel or 2) writing another command(s) to change the conversion mode. If the FIFO is not read when INT is served, it is cleared. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. Normal • • • • One conversion per channel from a sequence of channels CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by (FIFO read) reading out all of the FIFO contents up to the threshold, then write another command(s) to change the conversion mode. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. Normal • • • • Repeated conversions from a sequence of channels CS or FS to start sampling/conversion One INT generated after FIFO is filled up to the threshold Host must serve INT by either 1) (FIFO read) reading out all of the FIFO contents up to the threshold, then repeat conversions from the same selected channel or 2) writing another command(s) to change the conversion mode. If the FIFO is not read when INT is served it is cleared. Extended • Same as normal sampling except CSTART starts each sampling and conversion when CS is high. NOTES: 1. Programming the EOC/INT pin as the EOC signal works for mode 00 only. The other three modes automatically generate an INT signal irrespective of how EOC/INT is programmed. 2. Extended. Sampling mode using CSTART as the trigger only works when internal reference is selected for conversion modes 01, 10, and 11. 3. When using CSTART to sample in extended mode, the falling edge of the next CSTART trigger should occur no more than 2.5 µs after the falling CS edge (or falling FS edge if FS is active) of the channel select cycle. This is to prevent an ongoing conversion from being canceled. 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 timing diagrams The timing diagrams can be categorized into two major groups: nonconversion and conversion. The nonconversion cycles are read and write (configuration). None of these cycles carry a conversion. Conversion cycles are those four modes of conversion. read cycle (read FIFO or read CFR) read CFR cycle: The read command is decoded in the first 4 clocks. SDO outputs the contents of the CFR after the 4th SCLK. This command works only when the device is programmed in the single shot mode (mode 00). 1 2 3 4 5 7 6 13 12 14 15 16 1 SCLK CS FS SDI ID15 ID14 ID13 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ID12 INT EOC SDO ID15 ÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏ OD11 OD10 OD9 OD4 OD3 OD2 OD1 OD0 ÏÏÏÏ ÏÏÏÏ Figure 2. TLV2544/TLV2548 Read CFR Cycle (FS active) 1 2 3 4 ID14 ID13 ID12 5 6 7 12 13 14 15 16 1 SCLK CS FS ÏÏÏ SDI ID15 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ID15 ID14 INT EOC SDO ÏÏÏÏÏÏ ÏÏÏÏÏÏ OD11 OD10 OD9 OD4 OD3 OD2 OD1 OD0 ÏÏÏ ÏÏÏ Figure 3. TLV2544/TLV2548 Read CFR Cycle (FS = 1) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 read cycle (read FIFO or read CFR) (continued) FIFO read cycle The first command in the active cycle after INT is generated, if the FIFO is used, is assumed as the FIFO read command. The first FIFO content is output immediately before the command is decoded. If this command is not a FIFO read, then the output is terminated but the first data in the FIFO is retained until a valid FIFO read command is decoded. Use of more layers of the FIFO reduces the time taken to read multiple data. This is because the read cycle does not generate EOC or INT, nor does it carry out any conversion. 1 2 3 4 ID13 ID12 5 7 6 12 13 14 15 16 1 2 ID15 ID14 SCLK CS FS SDI INT ÏÏÏ ÏÏÏ ID15 ID14 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ EOC SDO OD11 OD10 OD9 OD8 OD7 OD6 OD5 ÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏ OD0 OD11 OD10 These devices can perform continuous FIFO read cycles (FS = 1) controlled by SCLK; SCLK can stop between each 16 SCLKs. Figure 4. TLV2544/TLV2548 FIFO Read Cycle (FS = 1) 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 write cycle (write CFR) The write cycle is used to write to the configuration register CFR (with 12-bit register content). The write cycle does not generate an EOC or INT, nor does it carry out any conversion (see power up and initialization requirements). 1 2 3 4 5 6 ID11 ID10 7 12 13 14 15 16 1 SCLK CS FS ÏÏÏÏ ÏÏÏÏ SDI ID15 ID14 ID13 ID12 ID9 ID4 ID3 ID2 ID1 INT EOC SDO ÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏ ID0 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ Figure 5. TLV2544/TLV2548 Write Cycle (FS Active) 1 2 3 4 5 6 7 12 13 ID15 ID14 ID13 ID12 ID11 ID10 ID9 ID4 ID3 14 15 16 ID1 ID0 ID15 ÏÏÏÏÏ ÏÏÏÏÏ 1 SCLK CS FS ÏÏÏ SDI ID2 ÏÏÏÏÏÏÏÏ ID15 ID14 INT EOC SDO ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏ ÏÏÏÏ Figure 6. TLV2544/TLV2548 Write Cycle (FS = 1) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 conversion cycles DSP/normal sampling 1 2 3 4 5 6 7 12 16 − Short Sampling 30 − Short Sampling 28 − Long Sampling 42 − Long Sampling (If CONV CLK = SCLK0 SCLK tc (30 or 42 SCLKs) CS FS SDI INT ÏÏÏ ÏÏÏ ID15 ID14 ID13 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ID12 ID15 t(sample) (12 or 24 SCLKs) ÏÏÏÏÏÏ ÏÏÏÏÏÏ EOC (SDOZ on SCLK16L Regardless of Sampling Time) SDO MSB-1 MSB MSB-2 MSB-3 MSB-4 MSB-5 MSB-6 t(conv) LSB MSB Figure 7. Mode 00 Single Shot/Normal Sampling (FS Signal Used) 16 − Short Sampling 1 2 3 4 5 6 7 12 13 28 − Long Sampling 30 − Short Sampling 42 − Long Sampling (If CONV CLK = SCLK0 1 SCLK tc (30 or 42 SCLKs) CS ÏÏÏÏ ÏÏÏÏ FS SDI ID15 ID14 ID13 ID12 ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ID15 INT t(sample) (12 or 24 SCLKs) EOC SDO ÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏ (SDOZ on SCLK16L Regardless of Sampling Time) MSB MSB-1 MSB-2 MSB-3 MSB-4 MSB-5 MSB-6 t(conv) LSB Figure 8. Mode 00 Single Shot/Normal Sampling (FS = 1, FS Signal not Used) 14 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 MSB                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 conversion cycles (continued) Device Going Into Extended Sampling Mode Select/Read Cycle Select/Read Cycle Read Cycle Device Get Out Extended Sampling Mode CS t(sample ) Normal Cycle CSTART ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ FS t(conv) † SDI † INT EOC SDO Previous Conversion Result Previous Conversion Result Hi-Z Hi-Z ÏÏÏÏ Hi-Z † This is one of the single shot commands. Conversion starts on next rising edge of CSTART. Figure 9. Mode 00 Single Shot/Extended Sampling (FS Signal Used, FS Pin Connected to TMS320 DSP) modes using the FIFO: modes 01, 10, 11 timing Configure Select Conversion #1 From Channel 2 Conversion #4 From Channel 2 Select CS FS CSTART ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏ ÏÏ ÏÏÏÏÏ ÏÏ SDI † § ¶ ¶ ¶ ‡ ‡ ‡ ‡ § ¶ INT SDO Hi-Z Hi-Z Read FIFO #1 Top of FIFO #2 #3 #4 † Command = Configure write for mode 01, FIFO threshold = 1/2 ‡ Command = Read FIFO, first FIFO read § Command = Select ch2. ¶ Use any channel select command to trigger SDI input. Figure 10. TLV2544/TLV2548 Mode 01 DSP Serial Interface (Conversions Triggered by FS) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 modes using the FIFO: modes 01, 10, 11 timing (continued) Conversion #1 From Channel 2 Configure Select CS Conversion #4 From Channel 2 Select ¶ FS (DSP) t(sample) t(sample) t(sample) t(sample) CSTART SDI INT SDO ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏ ÏÏÏ ÏÏÏÏ ÏÏÏ † § ‡ ‡ ‡ ‡ § Hi-Z Hi-Z Read FIFO #1 #2 First FIFO Read Sample Times ≥ MIN t(sample) (See Operating Characteristics) #3 #4 † Command = Configure write for mode 01, FIFO threshold = 1/2 ‡ Command = Read FIFO, first FIFO read § Command = Select ch2. ¶ Minimum CS low time for select cycle is 6 SCLKs. The same amount of time is required between FS low to CSTART for proper channel decoding. The low time of CSTART, not overlapped with CS low time, is the valid sampling time for the select cycle (see Figure 18). Figure 11. TLV2544/TLV2548 Mode 01 µp/DSP Serial Interface (Conversions Triggered by CSTART) Conversion From Channel 0 Configure Conversion From Channel 3 Conversion From Channel 0 Conversion From Channel 3 CS FS (DSP) CSTART SDI INT SDO ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏ ÏÏ † § § § Repeat § Read FIFO ‡ ‡ ‡ #1 #2 #3 Top of FIFO First FIFO Read ‡ #4 § § Repeat § § ‡ Read FIFO #1 Second FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0−1−2−3. ‡ Command = Read FIFO § Use any channel select command to trigger SDI input. Figure 12. TLV2544/TLV2548 Mode 10/11 DSP Serial Interface (Conversions Triggered by FS) 16 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 modes using the FIFO: modes 01, 10, 11 timing (continued) Conversion From Channel 0 Conversion From Channel 3 Conversion From Channel 3 Conversion From Channel 0 Configure CS FS (DSP) CSTART t(sample) t(sample) t(sample) t(sample) SDI INT ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ ‡ † ‡ ‡ ‡ #3 #4 ‡ SDO Read FIFO Repeat #1 #2 Top of FIFO Read FIFO Repeat #1 Second FIFO Read First FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0−1−2−3. ‡ Command = Read FIFO Figure 13. TLV2544/TLV2548 Mode 10/11 DSP Serial Interface (Conversions Triggered by CSTART) Conversion From Channel 0 Conversion From Channel 0 Conversion From Channel 3 Conversion From Channel 3 Configure CS CSTART ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ SDI † § § § § ‡ ‡ ‡ ‡ § § § § ‡ INT SDO Read FIFO Repeat #1 #2 #3 Top of FIFO First FIFO Read #4 Read FIFO #1 Repeat Second FIFO Read † Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0−1−2−3. ‡ Command = Read FIFO § Use any channel select command to trigger SDI input. Figure 14. TLV2544/TLV2548 Mode 10/11 µp Serial Interface (Conversions Triggered by CS) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 FIFO operation Serial SDO 12-BIT×8 FIFO ADC 7 6 FIFO Full 5 4 3 2 1 0 FIFO 1/2 Full FIFO 3/4 Full FIFO 1/4 Full FIFO Threshold Pointer Figure 15. TLV2544/TLV2548 FIFO The device has an 8-layer FIFO that can be programmed for different thresholds. An interrupt is sent to the host after the preprogrammed threshold is reached. The FIFO can be used to store data from either a fixed channel or a series of channels based on a preprogrammed sweep sequence. For example, an application may require eight measurements from channel 3. In this case, the FIFO is filled with eight data sequentially taken from channel 3. Another application may require data from channel 0, channel 2, channel 4, and channel 6 in an orderly manner. Therefore, the threshold is set for 1/2 and the sweep sequence 0−2−4−6−0−2−4−6 is chosen. An interrupt is sent to the host as soon as all four data are in the FIFO. In single shot mode, the FIFO automatically uses a 1/8 FIFO depth. Therefore the CFR bits (D1,0) controlling FIFO depth are don’t care. SCLK and conversion speed There are two ways to adjust the conversion speed. D The SCLK can be used as the source of the conversion clock to get the highest throughput of the device. The minimum onboard OSC is 3.6 MHz and 14 conversion clocks are required to complete a conversion. (Corresponding 3.86 µs conversion time) The devices can operate with an SCLK up to 20 MHz for the supply voltage range specified. When a more accurate conversion time is desired, the SCLK can be used as the source of the conversion clock. The clock divider provides speed options appropriate for an application where a high speed SCLK is used for faster I/O. The total conversion time is 14 × (DIV/fSCLK) where DIV is 1, 2, or 4. For example a 20 MHz SCLK with the divide by 4 option produces a {14 × (4/20 M)} = 2.8 µs conversion time. When an external serial clock (SCLK) is used as the source of the conversion clock, the maximum equivalent conversion clock (fSCLK/DIV) should not exceed 6 MHz. D Autopower down can be used to slow down the device at a reduced power consumption level. This mode is always used by the converter. If the device is not accessed (by CS or CSTART), the converter is powered down to save power. The built-in reference is left on in order to quickly resume operation within one half SCLK period. This provides unlimited choices to trade speed with power savings. reference voltage The device has a built-in reference with a programmable level of 2 V or 4 V. If the internal reference is used, REFP is set to 2 V or 4 V and REFM should be connected to the analog ground of the converter. An external reference can also be used through two reference input pins, REFP and REFM, if the reference source is programmed as external. The voltage levels applied to these pins establish the upper and lower limits of the analog inputs to produce a full-scale and zero-scale reading respectively. The values of REFP, REFM, and the analog input should not exceed the positive supply or be lower than GND consistent with the specified absolute maximum ratings. The digital output is at full scale when the input signal is equal to or higher than REFP and at zero when the input signal is equal to or lower than REFM. 18 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 reference block equivalent circuit INTERNAL REF Close = Int Ref Used Open = Ext Ref Used REFP Sample 0.1 µF Decoupling Cap 10 µF Internal Reference Compensation Cap Convert ~50 pF CDAC REFM (See Note A) External to the Device NOTES: A. If internal reference is used, tie REFM to analog ground and install a 10 µF (or 4.7 µF) internal reference compensation capacitor between REFP and REFM to store the charge as shown in the figure above. B. If external reference is used, the 10 µF (internal reference compensation) capacitor is optional. REFM can be connected to external REFM or AGND. C. Internal reference voltage drift, due to temperature variations, is approximately ±10 mV about the nominal 2 V (typically) from −10°C to 100°C. The nominal value also varies approximately ±50 mV across devices. D. Internal reference leakage during low ON time: Leakage resistance is on the order of 100 MΩ or more. This means the time constant is about 1000 s with 10 µF compensation capacitance. Since the REF voltage does not vary much, the reference comes up quickly after resuming from auto power down. At power up and power down the internal reference sees a glitch of about 500 µV when 2 V internal reference is used (1 mV when 4 V internal reference is used). This glitch settles out after about 50 µs. power down The device has three power-down modes. autopower-down mode The device enters the autopower-down state at the end of a conversion. In autopower-down, the power consumption reduces to about 1 mA when an internal reference is selected. The built-in reference is still on to allow the device to resume quickly. The resumption is fast enough (within 0.5 SCLK) for use between cycles. An active CS, FS, or CSTART resumes the device from power-down state. The power current is 1 µA when an external reference is programmed and SCLK stops. hardware/software power-down mode Writing 8000h to the device puts the device into a software power down state, and the entire chip (including the built-in reference) is powered down. For a hardware power-down, the dedicated PWDN pin provides another way to power down the device asynchronously. These two power-down modes power down the entire device including the built-in reference to save power. The power down current is reduced to about 1 µA is the SCLK is stopped. An active CS, FS, or CSTART restores the device. There is no time delay when an external reference is selected. However, if an internal reference is used, it takes about 20 ms to warm up. Deselect PWDN pin to remove the device from the hardware power-down state. This requires about 20 ms to warm up if an internal reference is also selected. The configuration register is not affected by any of the power down modes but the sweep operation sequence has to be started over again. All FIFO contents are cleared by the power-down modes. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 19                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 absolute maximum ratings over operating free-air temperature (unless otherwise noted)† Supply voltage range, GND to VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 6.5 V Analog input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VCC + 0.3 V Reference input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.3 V Digital input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VCC + 0.3 V Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 150°C Operating free-air temperature range, TA: TLV2544/48C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C TLV2544/48I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C 25 C POWER RATING DERATING FACTOR ABOVE TA = 25°C‡ TA = 70 70°C C POWER RATING TA = 85 85°C C POWER RATING TA = 125 125°C C POWER RATING D 1110 mW 8.9 mW/°C 710 mW 577 mW 222 mW DW 1294 mW 10.4 mW/°C 828 mW 673 mW 259 mW 16 PW 839 mW 6.7 mW/°C 537 mW 437 mW — 20 PW 977 mW 7.8 mW/°C 625 mW 508 mW — ‡ This is the inverse of the traditional junction-to-ambient thermal resistance (RΘJA). Thermal resistance is not production tested and the values given are for informational purposes only. recommended operating conditions MIN Supply voltage, VCC 2.7 Analog input voltage (see Note 4) 0 High level control input voltage, VIH NOM 3.3 MAX V VCC V 2.1 Low-level control input voltage, VIL UNIT 5.5 V 0.6 V Delay time, delay from CS falling edge to FS rising edge, td(CSL-FSH) (See Figure 16) 0.5 SCLKs Delay time, delay time from 16th SCLK falling edge to CS rising edge (FS = 1), or 17th rising edge (FS is active) td(SCLK-CSH) (See Figures 16, and 19) 0.5 SCLKs Setup time, FS rising edge before SCLK falling edge, tsu(FSH-SCLKL (See Figure 16) 20 ns Hold time, FS hold high after SCLK falling edge, th(FSH-SCLKL) (See Figure 16) 30 ns Pulse width, CS high time, twH(CS) (See Figures 16 and 19) 100 Pulse width, FS high time, twH(FS) (See Figure 16) 0.75 1 75 10000 50 10000 SCLK cycle time, tc(SCLK) (See Figures 16, and 19) VCC = 2.7 V to 3.6 V VCC = 4.5 V to 5.5V ns SCLKs ns NOTE 4: When binary output format is used, analog input voltages greater than that applied to REFP convert as all ones (111111111111), while input voltages less than that applied to REFM convert as all zeros (000000000000). The device is functional with reference down to 1 V. (VREFP − VREFM − 1); however, the electrical specifications are no longer applicable. 20 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 recommended operating conditions (continued) MIN NOM MAX UNIT Pulse width, SCLK low time, twL(SCLK) (See Figures 16 and 19) 0.4 0.6 SCLKs Pulse width, SCLK high time, twH(SCLK) (See Figures 16 and 19) 0.4 0.6 SCLKs Setup time, SDI valid before falling edge of SCLK (FS is active) or the rising edge of SCLK (FS=1), tsu(DI-SCLK (See Figures 16 and 19) 25 ns Hold time, SDI hold valid after falling edge of SCLK (FS is active) or the rising edge of SCLK (FS=1), th(DI-SCLK) (See Figure 16) 5 ns Delay time, delay from CS falling edge to SDO valid, td(CSL-DOV) (See Figures 16 and 19) Delay time, delay from FS falling edge to SDO valid, td(FSL-DOV) (See Figure 16) Delay time, delay from SCLK falling edge (FS is active) or SCLK rising edge (FS=1) to SDO valid, td(SCLK-DOV). (See Figures 16 and 19). For a date code later than xxx, see the date code information item (3). ns 25 ns SDO = 5 pF 0.5 SCLK 0.5 SCLK +9 SDO = 25 pF 0.5 SCLK 0.5 SCLK + 10 SDO = 5 pF 0.5 SCLK 0.5 SCLK + 18 SDO = 25 pF 0.5 SCLK 0.5 SCLK + 19 VCC = 4.5 V VCC = 2.7 V Delay time, delay from 17th SCLK rising edge (FS is active) or the 16th falling edge (FS=1) to EOC falling edge, td(SCLK-EOCL) (See Figures 16 and 19) Delay time, delay from 16th SCLK falling edge to INT falling edge (FS =1) or from the 17th rising edge SCLK to INT falling edge (when FS active), td(SCLK-INTL) (See Figure 19) 45 Pulse width, CSTART low time, twL(CSTART) (See Figures 17 and 18) Delay time, delay from CSTART rising edge to CSTART falling edge, td(CSTARTH-CSTARTL) (See Figure 18) Delay time, delay from CSTART rising edge to INT falling edge, td(CSTARTH-INTL) (See Figures 17 and 18) 50 100 ns ns 1 50 ns Min t(sample) µs Max t(conv) µs TLV2544C/TLV2548C TLV2544I/TLV2548I POST OFFICE BOX 655303 µs 1 Delay time, delay from CSTART rising edge to EOC falling edge, td(CSTARTH-EOCL) (See Figures 17 and 18) ns ns Min t(conv) Delay time, delay from CS falling edge or FS rising edge to INT rising edge, td(CSL-INTH) or td(FSH-INTH). See Figures 16, 17, 18 and 19) Delay time, delay from CS rising edge to CSTART falling edge, td(CSH-CSTARTL) (See Figures 17 and 18) Operating free-air temperature, TA 25 • DALLAS, TEXAS 75265 µs Max t(conv) 0 70 −40 85 °C 21                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 electrical characteristics over recommended operating free-air temperature range, VCC = VREFP = 2.7 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V, 15 MHz at 3 V (unless otherwise noted) PARAMETER TEST CONDITIONS VCC = 5.5 V, IOH = −0.2 mA at 25 pF load VOH High-level output voltage VOL Low-level output voltage IOZ Off-state output current (high-impedance-state) VO = VCC CS = VCC IOZ Off-state output current (high-impedance-state) VO = 0 CS = VCC IIH High-level input current VI = VCC IIL Low-level input current VI = 0 V VCC = 2.7 V, IOH = -20 µA at 25 pF load 0.1 ICC CS at 0 V, Ext ref Operating supply current, extended sampling CS at 0 V, Int ref Selected channel leakage current Maximum static analog reference current into REFP (use external reference) Input capacitance Zi Input MUX ON resistance −2.5 2.5 µA µA −1 0.005 2.5 µA −0.005 2.5 µA VCC = 4.5 V to 5.5 V 1.1 VCC = 2.7 V to 3.3 V 1 VCC = 4.5 V to 5.5 V 2.1 VCC = 2.7 V to 3.3 V 1.6 VCC = 4.5 V to 5.5 V 1.1 VCC = 2.7 V to 3.3 V 1 VCC = 4.5 V to 5.5 V 2.1 VCC = 2.7 V to 3.3 V 1.6 mA mA mA mA VCC = 4.5 V to 5.5 V, Ext clock 0.1 1 VCC = 2.7 V to 3.3 V, Ext clock 0.1 1 VCC = 4.5 V to 5.5 V, Ext clock, Ext ref 1‡ VCC = 2.7 V to 3.3 V, Ext ref, Ext clock 1.0§ Selected channel at VCC 1 Selected channel at 0 V 1 VREFP = VCC = 5.5 V, VREFM = GND 45 50 Control Inputs 5 25 VCC = 4.5 V 500 VCC = 2.7 V 600 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 µA A µA A µA 1 Analog inputs † All typical values are at VCC = 5 V, TA = 25°C. ‡ 1.2 mA if internal reference is used, 165 µA if internal clock is used. § 0.8 mA if internal reference is used, 116 µA if internal clock is used. 22 1 V µA A Auto power-down current for all digital inputs, 0 ≤ VI ≤ 0.3 V or VI ≥ VCC − 0.3 V, SCLK = 0 Ci UNIT V VCC−0.2 0.4 CS at 0 V, Int ref ICC(AUTOPWDN) MAX 2.4 VCC = 2.7 V, IOL = 20 µA at 25 pF load CS at 0 V, Ext ref ICC(PD) TYP† VCC = 5.5 V, IOL = 0.8 mA at 25 pF load Operating supply current, normal short sampling Power down supply current for all digital inputs, 0 ≤ VI ≤ 0.3 V or VI ≥ VCC − 0.3 V, SCLK = 0 MIN pF Ω                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 electrical characteristics over recommended operating free-air temperature range, VCC = VREFP = 2.7 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V, 15 MHz at 3 V (unless otherwise noted) (continued) ac specifications PARAMETER SINAD Signal-to-noise ratio +distortion THD Total harmonic distortion ENOB Effective number of bits SFDR Spurious free dynamic range TEST CONDITIONS fI = 12 kHz at 200 KSPS fI = 12 kHz at 200 KSPS MIN 69 C and I suffix TYP 70 −82 fI = 12 kHz at 200 KSPS fI = 12 kHz at 200 KSPS MAX dB −76 11.6 −84 UNIT dB Bits −75 dB Analog input Full power-bandwidth, −3 dB 1 MHz Full-power bandwidth, −1 dB 500 kHz reference specifications† (0.1 µF and 10 µF between REFP and REFM pins) PARAMETER TEST CONDITIONS Positive reference input voltage, REFP VCC = 2.7 V to 5.5 V VCC = 2.7 V to 5.5 V Negative reference input voltage, REFM VCC = 5.5 V Reference Input impedance VCC = 2.7 V 0 CS = 1, SCLK = 0, (off) CS = 0, SCLK = 20 MHz (on) CS = 1, SCLK = 0 (off) CS = 0, SCLK = 15 MHz (on) VCC = 2.7 V to 5.5 V VCC = 5.5 V VREF SELECT = 4 V Internal reference voltage, REFP−REFM VCC = 5.5 V VCC = 2.7 V Internal reference temperature coefficient † Specified by design MAX UNIT VCC 2 V 100 20 25 kΩ 100 20 V MΩ MΩ 25 3.85 4 VREF SELECT = 2 V 1.925 2 2.075 V VREF SELECT = 2 V 1.925 2 2.075 V • DALLAS, TEXAS 75265 2 kΩ VCC 4.15 VCC = 5.5 V, 2.7 V with 10 µF compensation cap VCC = 2.7 V to 5.5 V POST OFFICE BOX 655303 TYP 2 Reference Input voltage difference, REFP−REFM Internal reference start-up time MIN 20 16 V V ms 40† PPM/°C 23                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 operating characteristics over recommended operating free-air temperature range, VCC = VREFP = 2.7 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V, 15 MHz at 3 V (unless otherwise noted) PARAMETER TEST CONDITIONS UNIT ±1 LSB See Note 5 ±1 LSB See Note 5 ±2.5 LSB +3.5 LSB Integral linearity error (INL) (see Note 6) Differential linearity error (DNL) EO EFS Offset error (see Note 7) Full scale error (see Note 7) See Note 5 Self-test output code (see Table 1 and Note 8) Conversion time t(sample) Sampling time −1.6 SDI = B000h 800h (2048D) SDI = C000h 000h (0D) SDI = D000h FFFh (4095D) Internal OSC t(conv) TYP† MAX EL ED MIN 2.33 3.5 (14 DIV) f SCLK External SCLK With a maximum of 1-kΩ input source impedance 600 3.86 µs ns † All typical values are at TA = 25°C. NOTES: 5. Analog input voltages greater than that applied to REFP convert as all ones (111111111111), while input voltages less than that applied to REFM convert as all zeros (000000000000). 6. Linear error is the maximum deviation from the best straight line through the A/D transfer characteristics. 7. Zero error is the difference between 000000000000 and the converted output for zero input voltage: full-scale error is the difference between 111111111111 and the converted output for full-scale input voltage. 8. Both the input data and the output codes are expressed in positive logic. 24 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 INT EOC SDO SDI td(FSL-DOV) 1 Hi-Z OD11 ID15 OD10 ID14 ID1 ID0 don’t care 16 td(SCLK-INTL) td(SCLK-EOCL) don’t care 15 td(SCLK-CSH) t(conv) td(CSL-INTH) Hi-Z Figure 16. Critical Timing, DSP Mode (Normal Sampling, FS is Active) td(SCLK-DOV) 2 twL(SCLK) tsu(DI-SCLK) th(DI-SCLK) tc(SCLK) twH(SCLK) th(FSH-SCLKL) tWH(FS) ÎÎÎÎÎ ÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ td(CSL-DOV) SCLK tsu(FSH-SCLKL) FS td(CSL-FSH) twH(CS) td(FSL-DOV) OD15 td(FSH-INTH) ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ CS VOL VOH VOL VOH VOL VOH VIL VIH VIL VIH VIL VIH 8  8 8  8  8 8  8    8   8 88     SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 PARAMETER MEASUREMENT INFORMATION 25                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 PARAMETER MEASUREMENT INFORMATION SELECT CYCLE VIH CS VIL td(CSH-CSTARTL) twL(CSTART) VIH CSTART † VIL td(CSTARTH-INTL) t(CONV) VOH EOC VOL td(CSTARTH-EOCL) td(CSL-INTH) VOH INT VOL † CSTART falling edge may come before the rising edge of CS but no sooner than the fifth SCLK of the SELECT CYCLE. Figure 17. Critical Timing (Extended Sampling, Single Shot) SELECT CYCLE VIH CS twL(CSTART) VIL td(CSTARTH−CSTARTL) td(CSH-CSTARTL) VIH CSTART VIL † VOH EOC td(CSL-INTH) td(CSTARTH-EOCL) VOL td(CSTARTH-INTL) VOH INT VOL † CSTART falling edge may come before the rising edge of CS but no sooner than the fifth SCLK of the SELECT CYCLE. In this case, the actual sampling time is measured from the rising edge CS to the rising edge of CSTART. Figure 18. Critical Timing (Extended Sampling, Repeat/Sweep/Repeat Sweep) 26 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 INT EOC SDO SDI Hi-Z td(SCLK-DOV) td(CSL-DOV) ÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ SCLK OD10 ID14 th(DI-SCLK) don’t care ID0 16 td(SCLK-INTL) td(SCLK-EOCL) don’t care ID1 15 td(SCLK-CSH) t(conv) Hi-Z twH(CS) td(CSL-INTH) Figure 19. Critical Timing, Microprocessor Mode (Normal Sampling, FS = 1) OD11 ID15 2 twL(SCLK) tsu(DI-SCLK) 1 tc(SCLK) twH(SCLK) ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ CS VOL VOH VOL VOH VOL VOH VIL VIH VIL VIH VIL VIH 8  8 8  8  8 8  8    8   8 88     SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 PARAMETER MEASUREMENT INFORMATION POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 27                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TYPICAL CHARACTERISTICS INTEGRAL NONLINEARITY vs TEMPERATURE INTEGRAL NONLINEARITY vs TEMPERATURE 0.6 0.595 0.52 INL − Integral Nonlinearity − LSB INL − Integral Nonlinearity − LSB 0.53 0.51 0.5 0.49 0.48 VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.59 0.585 0.58 0.575 0.57 0.565 0.47 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C VCC = 5.5 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.56 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C 90 Figure 21 Figure 20 DIFFERENTIAL NONLINEARITY vs TEMPERATURE DIFFERENTIAL NONLINEARITY vs TEMPERATURE 0.48 0.494 DNL − Differential Nonlinearity − LSB DNL − Differential Nonlinearity − LSB 0.496 0.492 0.49 0.488 0.486 0.484 0.482 90 VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.47 0.46 0.45 0.44 0.43 VCC = 5.5 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.48 0.478 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C 90 0.42 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C Figure 22 28 Figure 23 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 90                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TYPICAL CHARACTERISTICS GAIN ERROR vs TEMPERATURE 1.2 0.5 1 0 0.8 −0.5 Gain Error − LSB Offset Error − LSB OFFSET ERROR vs TEMPERATURE 0.6 0.4 0.2 VCC = 5 V, Internal Reference = 4 V, External Oscillator = SCLK/4, Single Shot, Long Sample, Mode 00 µP Mode −1 −1.5 −2 0 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C VCC = 5 V, Internal Reference = 4 V, External Oscillator = SCLK/4, Single Shot, Long Sample, Mode 00 µP Mode −2.5 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C 90 Figure 24 90 Figure 25 SUPPLY CURRENT vs TEMPERATURE POWER DOWN CURRENT vs TEMPERATURE 1.4 0.4 External Reference = 4 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.2 Long Sample 1 Powerdown Current − µ A Supply Current − mA 1.2 Short Sample 0.8 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.6 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C VCC = 5 V 0 −0.2 −0.4 VCC = 2.7 V −0.6 VCC = 5.5 V −0.8 90 −1 −40 −23.75 −7.5 8.75 25 41.25 57.5 73.75 TA − Temperature − °C Figure 26 90 Figure 27 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 29                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TYPICAL CHARACTERISTICS INL − Integral Nonlinearity − LSB INTEGRAL NONLINEARITY vs SAMPLES 1.0 VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.5 0.0 −0.5 −1.0 0 Samples 4097 Figure 28 DNL − Differential Nonlinearity − LSB DIFFERENTIAL NONLINEARITY vs SAMPLES 1.0 VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.5 0.0 −0.5 −1.0 0 Samples 4097 Figure 29 INL − Integral Nonlinearity − LSB INTEGRAL NONLINEARITY vs SAMPLES 1.0 VCC = 5 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.5 0.0 −0.5 −1.0 0 Samples Figure 30 30 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 4097                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 DNL − Differential Nonlinearity − LSB TYPICAL CHARACTERISTICS DIFFERENTIAL NONLINEARITY vs SAMPLES 1.0 VCC = 5 V, Internal Reference = 2 V, Internal Oscillator, Single Shot, Short Sample, Mode 00 µP Mode 0.5 0.0 −0.5 −1.0 0 4097 Samples Magnitude − dB Figure 31 100% 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 VCC = 5 V, External Reference = 4 V, Internal Oscillator , Single Shot, Long Sample, Mode 00 µP Mode @ 200 KSPS 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 f − Frequency − kHz Figure 32 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 31                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TYPICAL CHARACTERISTICS SIGNAL-TO-NOISE + DISTORTION vs INPUT FREQUENCY 11.50 ENOB − Effective Number of Bits − BITS SINAD − Signal-to-Noise + Distortion − dB −67 −67.50 −68 −68.50 −69 −69.50 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Long Sample, Mode 00 µP Mode −70 −70.50 −71 EFFECTIVE NUMBER OF BITS vs INPUT FREQUENCY 11.40 11.30 11.20 11.10 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Long Sample, Mode 00 µP Mode 11 10.90 10.80 0 50 100 f − Frequency − kHz 0 150 50 100 f − Frequency − kHz Figure 33 Figure 34 SPURIOUS FREE DYNAMIC RANGE vs INPUT FREQUENCY −69 −73 −70 −74 Spurious Free Dynamic Range − dB THD − Total Harmonic Distortion − dB TOTAL HARMONIC DISTORTION vs INPUT FREQUENCY −71 −72 −73 −74 −75 −76 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Long Sample, Mode 00 µP Mode −77 −78 −79 0 50 100 f − Frequency − kHz −75 −76 −77 −78 −79 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Long Sample, Mode 00 µP Mode −80 −81 150 −82 0 Figure 35 32 150 50 100 f − Frequency − kHz Figure 36 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 150                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 TYPICAL CHARACTERISTICS SIGNAL-TO-NOISE RATIO vs INPUT FREQUENCY RNR − Signal-to-Noise Ratio − dB −70.2 VCC = 5 V, External Reference = 4 V, Internal Oscillator, Single Shot, Long Sample, Mode 00 µP Mode −70.4 −70.6 −70.8 −71 −71.2 −71.4 0 50 100 f − Frequency − kHz 150 Figure 37 PRINCIPLES OF OPERATION vcc 10 kΩ VDD XF CS TXD SDI RXD SDO AIN CLKR CLKX TMS320 DSP BIO FSR FSX INT SCLK TLV2544/ TLV2548 FS GND Figure 38. Typical Interface to a TMS320 DSP POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 33                                 SLAS198E − FEBRUARY 1999 − REVISED JUNE 2003 DATA CODE INFORMATION Parts with a date code earlier than 31xxxxx have the following discrepancies: 1. Earlier devices react to FS input irrespective of the state of the CS signal 2. The earlier silicon was designed with SDO prereleased half clock ahead. This means in the microcontroller mode (FS=1) the SDO is changed on the rising edge of SCLK with a delay; and for DSP serial port (when FS is active) the SDO is changed on the falling edge of SCLK with a delay. This helps the setup time for processor input data, but may reduce the hold time for processor input data. It is recommended that a 100 pF capacitance be added to the SDO line of the ADC when interfacing with a slower processor that requires longer input data hold time. 3. For earlier silicon, the delay time is specified as: MIN Delay time, delay from SCLK falling edge (FS is active) or SCLK rising edge (FS=1) to next SDO valid, td(SCLK-DOV). VCC = 4.5 V VCC = 2.7 V SDO = 0 pF 16 SDO = 100 pF 20 SDO = 0 pF 24 SDO = 100 pF 30 NOM MAX UNIT ns This is because the SDO is changed at the rising edge in the up mode with a delay. This is the hold time required by the external digital host processor, therefore, a minimum value is specified. The newer silicon has been revised with SDO changed at the falling edge in the up mode with a delay. Since at least 0.5 SCLK exists as the hold time for the external host processor, the specified maximum value helps with the calculation of the setup time requirement of the external digital host processor. For an explanation of the DSP mode, reverse the rising/falling edges in item (2) above. 34 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PACKAGE OPTION ADDENDUM www.ti.com 14-Oct-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) Samples (4/5) (6) TLV2544CD ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 2544C Samples TLV2544CDR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 2544C Samples TLV2544CPW ACTIVE TSSOP PW 16 90 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TV2544 Samples TLV2544CPWR ACTIVE TSSOP PW 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TV2544 Samples TLV2544ID ACTIVE SOIC D 16 40 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 2544I Samples TLV2544IDR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 2544I Samples TLV2544IPW ACTIVE TSSOP PW 16 90 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TY2544 Samples TLV2544IPWR ACTIVE TSSOP PW 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TY2544 Samples TLV2548CDW ACTIVE SOIC DW 20 25 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 2548C Samples TLV2548CDWR ACTIVE SOIC DW 20 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 2548C Samples TLV2548CPW ACTIVE TSSOP PW 20 70 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TV2548 Samples TLV2548CPWR ACTIVE TSSOP PW 20 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TV2548 Samples TLV2548IDW ACTIVE SOIC DW 20 25 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 2548I Samples TLV2548IDWR ACTIVE SOIC DW 20 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 2548I Samples TLV2548IPW ACTIVE TSSOP PW 20 70 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TY2548 Samples TLV2548IPWG4 ACTIVE TSSOP PW 20 70 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TY2548 Samples TLV2548IPWR ACTIVE TSSOP PW 20 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 TY2548 Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. Addendum-Page 1 PACKAGE OPTION ADDENDUM www.ti.com 14-Oct-2022 OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TLV2548EVM 价格&库存

很抱歉,暂时无法提供与“TLV2548EVM”相匹配的价格&库存,您可以联系我们找货

免费人工找货