0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TLV62090EVM-125

TLV62090EVM-125

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    -

  • 描述:

    TLV62090 DCS-Control™ DC/DC, Step Down 1, Non-Isolated Outputs Evaluation Board

  • 数据手册
  • 价格&库存
TLV62090EVM-125 数据手册
User's Guide SLVU693B – March 2012 – Revised May 2012 TLV62090EVM-125 Evaluation Module This user’s guide describes the TLV62090 evaluation module (EVM) and how to perform a stand-alone evaluation or interface with a host or a system. The TLV62090 is a step-down converter that operates with an input voltage between 2.5 V and 6 Vdc, an output voltage of 1.8 V using external resistors, and can deliver up to 3000 mA of continuous current. The converter has a programmable soft-start, a power-out good status, and several other safety features. See the data sheet for the complete description. 1 2 3 4 5 Contents Introduction .................................................................................................................. Considerations When Evaluating theTLV62090 ........................................................................ Test Summary ............................................................................................................... 3.1 Equipment ........................................................................................................... 3.2 Equipment and EVM Setup ....................................................................................... 3.3 Test Procedure ..................................................................................................... Waveforms ................................................................................................................... Schematic, Printed-Circuit Board Layout, and Bill of Materials ....................................................... 5.1 Schematic ........................................................................................................... 5.2 Printed-Circuit Board Layouts .................................................................................... 5.3 Bill of Materials ..................................................................................................... 2 2 2 2 2 3 4 7 7 8 9 List of Figures 1 EVM Schematic and Evaluation Setup ................................................................................... 3 2 Typical Switching Waveforms ............................................................................................. 4 3 Low-Power Mode, 25-Ω Load – Shows Burst Low-Power Mode 4 5 6 7 8 9 10 .................................................... Power Up by Powering Laboratory Supply Connected to Vin ........................................................ Power Up by Hot Plugging Vin ............................................................................................ Power Up by Enable Pin Pulled High .................................................................................... Power Down by Enable Pulled Low ...................................................................................... Assembly Layer ............................................................................................................. Top Layer ................................................................................................................... Bottom Layer ................................................................................................................ 4 5 5 6 6 8 8 9 List of Tables ....................................................... 1 Setup I/O Connections and Configuration for TLV62090EVM 2 PWR125A Bill of Materials ................................................................................................. 9 2 DCS Control is a trademark of Texas Instruments. SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback TLV62090EVM-125 Evaluation Module Copyright © 2012, Texas Instruments Incorporated 1 Introduction 1 www.ti.com Introduction The TLV62090 device family is a high-frequency, synchronous, step-down converter optimized for small solution size, high efficiency, and is suitable for battery-powered applications. To maximize efficiency, the converter operates in PWM mode with a nominal switching frequency of 1.4 MHz and automatically enters Power Save Mode operation at light-load currents. When used in distributed power supplies and point-ofload regulation, the device allows voltage tracking to other voltage rails and tolerates capacitors ranging from 22 µF up to 100 µF. Using the DCS Control™ topology, the device achieves excellent load transient performance and accurate output voltage regulation. The device is available in 3 x 3-mm, 16-pin package with thermal pad. 2 Considerations When Evaluating theTLV62090 The TLV62090 integrated circuit (IC) has a two-stage, input current limit that sets the initial current limit to one third (~1.55 A) of the normal peak current limit of approximately 4.6 A, when the output is less than 0.6 V. Most system loads do not become enabled or active until the output has reached 0.8 V, which is after the initial start-up current limit. If a low-resistance load is used (less than approximately 1 Ω), the part may get stuck in short-circuit mode during power up. Thus, very heavy loads may have to be applied after power up or the user can place an N-CH logic level FET in series with the resistor (drain connected to ground side of resistor, source connected to ground and gate tied to the drain). Once the output reaches approximately 1 V, the load turns on. 3 Test Summary The TLV62090EVM-125 board requires an adjustable dc power supply with up to a 6-V output and ≥ 2.5 A for powering the input to the EVM and a resistive output load between 1 kΩ and 0.6 Ω. Choose the proper power rating for the load resistor, P = V2 / R. Use at least 2x the calculated power dissipation. The test setup connections and jumper settings selections are configured for a stand-alone evaluation, but can be changed to interface with external hardware such as a system load and microcontroller. 3.1 Equipment • • • • 3.2 Adjustable dc power supply between 2.5 V and 6 V with adjustable current limit set to approximately 2.5 A Load: System load, resistive load of 2 Ω, 3 W and 25 Ω Three Fluke 75 digital multimeters (DMM); (equivalent or better) Oscilloscope, model TDS222 (equivalent or better) Equipment and EVM Setup Table 1 shows the setup input/output connections and configuration of the TLV62090 evaluation module. The silk screen labels appear in parentheses. Table 1. Setup I/O Connections and Configuration for TLV62090EVM Jack/Component (Silk Screen) Connect or Adjustment to: J1-1/2 (Vin) P/S positive lead, preset to 4.5 Vdc; 2.5A Current Limit J2-1 (+ SNS) Input positive lead of DMM #1 J2-2 (– SNS) Input negative lead of DMM #1 J3-1/2 (GND) P/S negative lead. J5-1/2 (Vout) Positive lead to system load or load resistance J6-1 (+ SNS) Output positive lead of DMM #2 J6-2 (– SNS) Output negative lead of DMM #2 J7-1/2 (GND) Negative lead to system load or load resistance J4-1 (PG) Positive lead of DMM #3 J4-2 (GND) Negative lead of DMM #3 JP1-1/2 (ON) Apply shunt to ON for converter operation JP1-2/3 (OFF) 2 TLV62090EVM-125 Evaluation Module SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated Test Summary www.ti.com Connect the meters, scope probes (see Figure 1), 2-Ω output load, shunt jumpers, and input power supply ( Table 1); set the oscilloscope to 200 ns/div, positive trigger, or HF trigger on CH2; CH1: ac-coupled, 50 mV/div; CH2: dc-coupled, 2 V/div; CH3: ac-coupled, 10 mV/div; CH4: dc-coupled, 10 V/div. Users can replace the resistive load with a system load or decade load box to vary the load (2-Ω to 25-Ω load). Figure 1. EVM Schematic and Evaluation Setup 3.3 Test Procedure 1. Set up the EVM according to Table 1 and Figure 1, and preset the power supply 4.5 Vdc at approximately 2.5-A current limit. 2. Turn on input supply, and verify that the input voltage is approximately 4.5 Vdc (DMM#1) and the output voltage is at approximately 1.8 Vdc (DMM#2). 3. Refer to Figure 2, and verify that the duty cycle is near 40%, input ripple is less than 50 mVpp (ignoring switching spikes) and the output ripple is less than 10 mVpp. These waveforms were taken with high-frequency probes (meaning that the ground lead was short (approximately 1 cm). This reduces the high-frequency spikes that the ground loop on the probe picks up. 4. Vary input voltage between 2.6 V and 5.5 V, and observe the change in duty cycle and ripple waveforms. Set Vin back to 4.5 Vdc. 5. Change the output load to 25 Ω, set CH3 to 50 mV/div, and verify how the duty cycle changes into a burst low-power mode (see Figure 3). At the end of the burst switching, the inductor’s current goes to zero, becomes discontinuous, and rings with the FET and output capacitance (normal operation at light loads). Set the load back to approximately 2 Ω. 6. Turn off the input supply. Set CH1 to dc coupled, 2 V/div; set CH3 to dc coupled, 1 V/div; CH4 to dc coupled, 5 V/div; set the oscilloscope timing to 500 µs/div; set the oscilloscope trigger to positive or HF trigger on CH1 and arm scope. Turn on the laboratory supply. The laboratory supply that captured Figure 4 ramped up over 3 ms. Figure 5 is a hot plug power up. The output ramp rate is the same in both figures due to the controlled soft-start. The user can program the output to track another voltage with the soft-start pin. See the data sheet for more details. 7. Move CH1 to JP1-2 (Enable pin), and set JP1 shunt to off. Arm the oscilloscope, and remove JP1 shunt. Figure 6 shows the power up of the converter by the enable pin. 8. Set the oscilloscope trigger to negative, arm the oscilloscope, and apply a shunt on JP1-OFF. See Figure 7 for the power-down sequence. 9. With an understanding of the basic functions of the EVM, users may want to integrate the EVM into their system using short, twisted wires, to minimize connection impedances. SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback TLV62090EVM-125 Evaluation Module Copyright © 2012, Texas Instruments Incorporated 3 Waveforms 4 www.ti.com Waveforms Vin_ac Vsw Vout Time - 200 ns/div 4.5V input, 1.8V output, 1.4MHz Switching; CH1: Input Ripple, CH2: Switching Node, CH3: Output Ripple Figure 2. Typical Switching Waveforms Vin_ac Vsw Vout_ac Time - 2 ms/div Figure 3. Low-Power Mode, 25-Ω Load – Shows Burst Low-Power Mode 4 TLV62090EVM-125 Evaluation Module SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated Waveforms www.ti.com Vpg Vin_ac Vsw Vout Time - 50 ms/div Figure 4. Power Up by Powering Laboratory Supply Connected to Vin Vpg Vin_ac Vsw Vout Time - 500 ms/div Figure 5. Power Up by Hot Plugging Vin SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback TLV62090EVM-125 Evaluation Module Copyright © 2012, Texas Instruments Incorporated 5 Waveforms www.ti.com Vpg Ven Vsw Vout Time - 500 ms/div Figure 6. Power Up by Enable Pin Pulled High Vpg Ven Vsw Vout Time - 10 ms/div Figure 7. Power Down by Enable Pulled Low 6 TLV62090EVM-125 Evaluation Module SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated Schematic, Printed-Circuit Board Layout, and Bill of Materials www.ti.com PG GND 1 J4 1 1 2 1 R2 158k 1 C4 AGND 6 PG 4 9 SS FB 5 VOS 16 SW 2 10nF R1 1.0 uH SW 1 1 17 AGND CN CP 8 7 EN 13 AVIN 3 DEF 1 22uF See BOM for part usage 1 1 GND 2 1 2 2 S- J3 1 J2 S+ 2 1 J1 VIN 2.3V to 6V Not Installed 1 47uF C3 + ON EN OFF 1 JP1 R4 1.00M C1 C5 10nF VIN 10 PVIN 11 12 14 PGND PVIN 15 PGND U1 TLV6209x 2 TP1 L1 200k 1 1 C9 R3 500k 1 C2 22uF 1 1 C8 1 1 C7 1 1 C6 2 GND J7 S+ S2 J6 1 J5 VOUT Schematic 1.8V, 1.2A max 5.1 2 Schematic, Printed-Circuit Board Layout, and Bill of Materials 1 5 SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback TLV62090EVM-125 Evaluation Module Copyright © 2012, Texas Instruments Incorporated 7 Schematic, Printed-Circuit Board Layout, and Bill of Materials 5.2 www.ti.com Printed-Circuit Board Layouts Figure 8. Assembly Layer Figure 9. Top Layer 8 TLV62090EVM-125 Evaluation Module SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated Schematic, Printed-Circuit Board Layout, and Bill of Materials www.ti.com Figure 10. Bottom Layer 5.3 Bill of Materials Table 2. PWR125A Bill of Materials Count -001 RefDes Value Description Size Part Number MFR 2 C1-2 22µF Capacitor, Ceramic Chip, 10V, X5R, 10% 0805 STD STD 1 C3 47µF Capacitor, Tantalum, 8V, 35milliohm, 20% 3528(B) T520B476M008ATE035 Kemet 2 C4-5 10nF Capacitor, Ceramic, 25V, X5R, 10% 0603 Std Std 0 C6-7 open Capacitor, Ceramic 1210 Std Std 0 C8 open Capacitor, Ceramic 0805 Std Std 0 C9 Capacitor, Ceramic, 50V, C0G, 5% 0603 Std Std 7 J1-7 PEC02SAAN Header, Male 2-pin, 100mil spacing 0.100 inch x 2 PEC02SAAN Sullins 1 JP1 PEC03SAAN Header, 3 pin, 100mil spacing 0.100 x 3 PEC03SAAN Sullins 1 L1 1.0 µH Inductor, Power, 4.5A, ±20% 0.157 x 0.157 inch XFL4020-102ML Coilcraft 1 R1 200k Resistor, Chip, 1/16W, 1% 0603 Std Std 1 R2 158k Resistor, Chip, 1/16W, 1% 0603 Std Std 1 R3 500k Resistor, Chip, 1/16W, 1% 0603 Std Std 1 R4 1.00M Resistor, Chip, 1/16W, 1% 0603 Std Std 0 TP1 STD Test Point, O.032 Hole 0.032 Std Std 1 U1 TLV62090RGT IC, 3A High Efficient Synchronous Step Down Converter QFN-16 TLV62090RGT TI 1 – – Shunt, 100-mil, Black 0.100 929950-00 3M 1 – – PCB 1.8 x 1.8 x 0.031 inch PWR125 Any 1 – – Label (See note 5) 1.25 x 0.25 inch THT-13-457-10 Brady SLVU693B – March 2012 – Revised May 2012 Submit Documentation Feedback TLV62090EVM-125 Evaluation Module Copyright © 2012, Texas Instruments Incorporated 9 EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. REGULATORY COMPLIANCE INFORMATION As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference. General Statement for EVMs including a radio User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization. For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Interference Statement for Class A EVM devices This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Interference Statement for Class B EVM devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For EVMs annotated as IC – INDUSTRY CANADA Compliant This Class A or B digital apparatus complies with Canadian ICES-003. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Concerning EVMs including radio transmitters This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Concerning EVMs including detachable antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada. Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement. Concernant les EVMs avec appareils radio Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Concernant les EVMs avec antennes détachables Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER 【Important Notice for Users of this Product in Japan】 】 This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product: 1. 2. 3. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan, Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan. Texas Instruments Japan Limited (address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan http://www.tij.co.jp 【ご使用にあたっての注】 本開発キットは技術基準適合証明を受けておりません。 本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。 1. 2. 3. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。 実験局の免許を取得後ご使用いただく。 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。    上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product. Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1. 2. 3. 4. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard. You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials. Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs. Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected. Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated
TLV62090EVM-125 价格&库存

很抱歉,暂时无法提供与“TLV62090EVM-125”相匹配的价格&库存,您可以联系我们找货

免费人工找货