TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
TMP102 Low-Power Digital Temperature Sensor With SMBus and Two-Wire Serial
Interface in SOT563
1 Features
3 Description
•
The TMP102 device is a digital temperature sensor
ideal for NTC/PTC thermistor replacement where high
accuracy is required. The device offers an accuracy
of ±0.5°C without requiring calibration or external
component signal conditioning. Device temperature
sensors are highly linear and do not require complex
calculations or lookup tables to derive the
temperature. The on-chip 12-bit ADC offers
resolutions down to 0.0625°C.
1
•
•
•
•
•
•
SOT563 Package (1.6-mm × 1.6-mm) is a 68%
Smaller Footprint than SOT-23
Accuracy Without Calibration:
– 2.0°C (max) from –25°C to 85°C
– 3.0°C (max) from –40°C to 125°C
Low Quiescent Current:
– 10-μA Active (max)
– 1-μA Shutdown (max)
Supply Range: 1.4 to 3.6 V
Resolution: 12 Bits
Digital Output: SMBus, Two-Wire, and I2C
Interface Compatibility
NIST Traceable
2 Applications
•
•
•
•
•
•
•
•
•
The 1.6-mm × 1.6-mm SOT563 package is 68%
smaller footprint than an SOT-23 package. The
TMP102 device features SMBus™, two-wire and I2C
interface compatibility, and allows up to four devices
on one bus. The device also features an SMBus alert
function. The device is specified to operate over
supply voltages from 1.4 to 3.6 V with the maximum
quiescent current of 10 µA over the full operating
range.
The TMP102 device is ideal for extended temperature
measurement in a variety of communication,
computer, consumer, environmental, industrial, and
instrumentation applications. The device is specified
for operation over a temperature range of –40°C to
125°C.
Portable and Battery-Powered Applications
Power-supply Temperature Monitoring
Computer Peripheral Thermal Protection
Notebook Computers
Battery Management
Office Machines
Thermostat Controls
Electromechanical Device Temperatures
General Temperature Measurements:
– Industrial Controls
– Test Equipment
– Medical Instrumentations
The TMP102 production units are 100% tested
against sensors that are NIST-traceable and are
verified with equipment that are NIST-traceable
through ISO/IEC 17025 accredited calibrations.
Device Information(1)
PART NUMBER
TMP102
PACKAGE
BODY SIZE (NOM)
SOT563 (6)
1.60 mm × 1.20 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Simplified Schematic
Supply Voltage
1.4 V to 3.6 V
Supply Bypass
Capacitor
Pullup Resistors
Block Diagram
Temperature
0.01 µF
5k
SCL
1
Diode
Temp.
Sensor
Control
Logic
6
DS
A/D
Converter
Serial
Interface
5
OSC
Config.
and Temp.
Register
SDA
TMP102
Two-Wire
Host Controller
1
2
3
SCL
GND
ALERT
SDA
V+
6
GND
2
V+
5
4
ADD0
ALERT
3
4
ADD0
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Table of Contents
1
2
3
4
5
6
7
Features ..................................................................
Applications ...........................................................
Description .............................................................
Revision History.....................................................
Pin Configuration and Functions .........................
Specifications.........................................................
1
1
1
2
4
4
6.1
6.2
6.3
6.4
6.5
6.6
6.7
4
4
5
5
5
6
7
Absolute Maximum Ratings .....................................
Handling Ratings.......................................................
Recommended Operating Conditions.......................
Thermal Information ..................................................
Electrical Characteristics...........................................
Timing Requirements ...............................................
Typical Characteristics ..............................................
Detailed Description .............................................. 8
7.1 Overview ................................................................... 8
7.2 Functional Block Diagram ......................................... 8
7.3 Feature Description................................................... 8
7.4 Device Functional Modes........................................ 14
7.5 Programming........................................................... 15
8
Application and Implementation ........................ 21
8.1 Application Information............................................ 21
8.2 Typical Application .................................................. 21
9 Power Supply Recommendations...................... 23
10 Layout................................................................... 23
10.1 Layout Guidelines ................................................. 23
10.2 Layout Example .................................................... 23
11 Device and Documentation Support ................. 24
11.1
11.2
11.3
11.4
11.5
11.6
Documentation Support .......................................
Receiving Notification of Documentation Updates
Community Resources..........................................
Trademarks ...........................................................
Electrostatic Discharge Caution ............................
Glossary ................................................................
24
24
24
24
24
24
12 Mechanical, Packaging, and Orderable
Information ........................................................... 24
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision G (September 2018) to Revision H
Page
•
Changed Absolute Maximum Ratings for voltage at SCL, SDA and ADD0 pin ..................................................................... 4
•
Changed Absolute Maximum Ratings for voltage at ALERT pin............................................................................................ 4
Changes from Revision F (September 2018) to Revision G
Page
•
Changed input voltage maximum value from: 3.6 V to: 4 V................................................................................................... 4
•
Changed output voltage maximum value from: 3.6 V to: ((V+) + 0.5) and ≤ 4 V ................................................................... 4
•
Changed Junction-to-ambient thermal resistance from 200 °C/W to 210.3 °C/W ................................................................. 5
•
Changed Junction-to-case (top) thermal resistance from 73.7 °C/W to 105.0 °C/W ............................................................. 5
•
Changed Junction-to-board thermal resistance from 34.4 °C/W to 87.5 °C/W ...................................................................... 5
•
Changed Junction-to-top characterization parameter from 3.1 °C/W to 6.1 °C/W ................................................................. 5
•
Changed Junction-to-board characterization parameter from 34.2 °C/W to 87.0 °C/W......................................................... 5
•
Added the Receiving Notification of Documentation Updates section ................................................................................ 24
Changes from Revision E (April 2015) to Revision F
Page
•
Added TI Design .................................................................................................................................................................... 1
•
Added NIST Features bullet .................................................................................................................................................. 1
•
Added last paragraph of Description section ......................................................................................................................... 1
Changes from Revision D (December 2014) to Revision E
Page
•
Changed the MAX value for the Supply voltage from 3.6 to 4 in the Absolute Maximum Ratings table ............................... 4
•
Changed MIN, TYP, and MAX values for the Temperature Accuracy (temperature error) parameter .................................. 5
•
Changed the frequency from 2.85 to 3.4 MHz in the POWER SUPPLY section of the Electrical Characteristics table ....... 6
•
Changed the Temperature Error vs Temperature graph in the Typical Characteristics section ............................................ 7
2
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
•
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
Changed the Temperature Error at 25°C graph in the Typical Characteristics section ......................................................... 7
Changes from Revision C (October 2012) to Revision D
Page
•
Added Handling Rating table, Feature Description section, Device Functional Modes, Application and
Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation
Support section, and Mechanical, Packaging, and Orderable Information section ............................................................... 4
•
Changed parameters in Timing Requirements ...................................................................................................................... 6
Changes from Revision B (October 2008) to Revision C
•
Page
Changed values for Data Hold Time parameter in Timing Requirements .......................................................................... 12
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
3
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
5 Pin Configuration and Functions
DRL Package
6-Pin SOT563
Top View
1
GND
2
ALERT
3
CBZ
SCL
6
SDA
5
V+
4
ADD0
Pin Functions
PIN
NO.
NAME
I/O
DESCRIPTION
1
SCL
I
2
GND
—
Serial clock. Open-drain output; requires a pullup resistor.
Ground
3
ALERT
O
Overtemperature alert. Open-drain output; requires a pullup resistor.
4
ADD0
I
Address select. Connect to GND or V+
5
V+
I
Supply voltage, 1.4 V to 3.6 V
6
SDA
I/O
Serial data. Open-drain output; requires a pullup resistor.
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
MIN
MAX
UNIT
4
V
4
V
((V+) + 0.3)
and ≤ 4
V
150
°C
150
°C
150
°C
Supply Voltage
Voltage at SCL, SDA and ADD0 (2)
–0.5
Voltage at ALERT
Operating temperature
–55
Junction temperature
Storage temperature, Tstg
(1)
(2)
–60
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not supported.
Input voltage rating applies to all TMP102 input voltages.
6.2 Handling Ratings
VALUE
V(ESD)
(1)
(2)
4
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1)
±2000
Charged-device model (CDM), per JEDEC specification JESD22-C101 (2)
±1000
Machine model (MM)
±200
UNIT
V
Level listed above is the passing level per ANSI, ESDA, and JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows
safe manufacturing with a standard ESD control process.
Level listed above is the passing level per EIA-JEDEC JESD22-C101. JEDEC document JEP157 states that 250-V CDM allows safe
manufacturing with a standard ESD control process.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
3.3
V+
Supply voltage
1.4
TA
Operating free-air temperature
–40
MAX
UNIT
3.6
V
125
°C
6.4 Thermal Information
TMP102
THERMAL METRIC (1)
DRL (SOT563)
UNIT
6 PINS
RθJA
Junction-to-ambient thermal resistance
210.3
°C/W
RθJC(top)
Junction-to-case (top) thermal resistance
105.0
°C/W
RθJB
Junction-to-board thermal resistance
87.5
°C/W
ψJT
Junction-to-top characterization parameter
6.1
°C/W
ψJB
Junction-to-board characterization parameter
87.0
°C/W
(1)
For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report (SPRA953).
6.5 Electrical Characteristics
At TA = 25°C and VS = 1.4 to 3.6 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
125
°C
TEMPERATURE INPUT
Range
–40
Accuracy (temperature error)
–25°C to 85°C
–40°C to 125°C
vs supply
Resolution
±0.5
±2
±1
±3
0.2
0.5
°C
°C/V
0.0625
°C
3
pF
DIGITAL INPUT/OUTPUT
Input capacitance
VIH
Input logic high
VIL
Input logic low
IIN
Input current
3.6
–0.5
0.3 × (V+)
V
1
μA
0 < VIN < 3.6 V
SDA
VOL
0.7 × (V+)
Output logic
ALERT
V+ > 2 V, IOL = 3 mA
0
0.4
V+ < 2 V, IOL = 3 mA
0
0.2 × (V+)
V+ > 2 V, IOL = 3 mA
0
0.4
V+ < 2 V, IOL = 3 mA
0
0.2 × (V+)
Resolution
12
Conversion time
26
Conversion modes
CR1 = 0, CR0 = 0
0.25
CR1 = 0, CR0 = 1
1
CR1 = 1, CR0 = 0 (default)
4
CR1 = 1, CR0 = 1
8
Timeout time
30
V
V
Bit
35
ms
Conv/s
40
ms
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
5
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Electrical Characteristics (continued)
At TA = 25°C and VS = 1.4 to 3.6 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
+3.6
V
POWER SUPPLY
Operating supply range
IQ
ISD
Average quiescent current
Shutdown current
+1.4
Serial bus inactive, CR1 = 1, CR0 =
0 (default)
7
Serial bus active, SCL frequency =
400 kHz
15
Serial bus active, SCL frequency =
3.4 MHz
85
Serial bus inactive
0.5
Serial bus active, SCL frequency =
400 kHz
10
Serial bus active, SCL frequency =
3.4 MHz
80
10
μA
1
μA
TEMPERATURE
Specified range
–40
125
°C
Operating range
–55
150
°C
6.6 Timing Requirements
See the Timing Diagrams section for additional information.
FAST MODE
MIN
V+
0.001
TYP
HIGH-SPEED MODE
MAX
MIN
0.4
0.001
TYP
MAX
UNIT
ƒ(SCL)
SCL operating frequency
t(BUF)
Bus-free time between STOP and
START condition
2.85 MHz
600
160
ns
t(HDSTA)
Hold time after repeated START
condition.
After this period, the first clock is
generated.
600
160
ns
t(SUSTA)
repeated start condition setup time
600
160
ns
t(SUSTO)
STOP condition setup time
600
160
ns
t(HDDAT)
Data hold time
100
t(SUDAT)
Data setup time
100
25
ns
t(LOW)
SCL-clock low period
V+ , see Figure 7
1300
210
ns
t(HIGH)
SCL-clock high period
See Figure 7
600
60
ns
tFD
Data fall time
See Figure 7
300
See Figure 7
300
ns
1000
ns
See Figure 7
900
25
105
80
ns
ns
tRD
Data rise time
SCLK ≤ 100 kHz,
see Figure 7
tFC
Clock fall time
See Figure 7
300
40
ns
tRC
Clock rise time
See Figure 7
300
40
ns
6
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
6.7 Typical Characteristics
20
10
18
9
16
8
14
7
12
10
ISD (μA)
IQ (μA)
At TA = 25°C and V+ = 3.3 V, unless otherwise noted.
3.6 V Supply
8
6
6
5
3.6 V Supply
4
3
4
1.4 V Supply
1.4 V Supply
2
2
1
0
-60
-40 -20
0
20
40
60
80
0
100 120 140 160
-60
Temperature (°C)
-40 -20
0
20
40
60
80
100 120 140 160
Temperature (°C)
Four conversions per second
Figure 1. Average Quiescent Current vs Temperature
100
38
90
36
80
34
70
32
IQ (μA)
1.4 V Supply
30
60
50
40
28
26
24
20
22
10
+25 °C
-55 °C
0
20
-40 -20
0
20
40
60
80
1k
100 120 140 160
100k
1M
10M
Bus Frequency (Hz)
Figure 3. Conversion Time vs Temperature
Figure 4. Quiescent Current vs Bus Frequency
(Temperature at 3.3-V Supply)
1
70
Mean
Mean + 3 V
Mean 3 V
0.8
0.6
60
50
Population
0.4
0.2
0
-0.2
40
30
20
-0.4
-0.6
D002
Figure 5. Temperature Error vs Temperature
0.4
0.3
0.2
0.1
0
0.35
140
0.25
120
0.15
100
0.05
20
40
60
80
Temperature (qC)
-0.1
0
-0.05
-20
-0.2
-40
-0.15
0
-0.3
10
-0.8
-1
-60
10k
Temperature (°C)
-0.25
-60
Temperature Error (qC)
+125 °C
30
3.6 V Supply
-0.35
Conversion Time (ms)
Figure 2. Shutdown Current vs Temperature
40
D001
Temperature Error (qC)
Figure 6. Temperature Error at 25°C
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
7
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
7 Detailed Description
7.1 Overview
The TMP102 device is a digital temperature sensor that is optimal for thermal-management and thermalprotection applications. The TMP102 device is two-wire, SMBus and I2C interface-compatible. The device is
specified over an operating temperature range of –40°C to 125°C. See Functional Block Diagram for a block
diagram of the TMP102 device.
The temperature sensor in the TMP102 device is the chip itself. Thermal paths run through the package leads as
well as the plastic package. The package leads provide the primary thermal path because of the lower thermal
resistance of the metal.
An alternative version of the TMP102 device is available. The TMP112 device has highest accuracy, the same
micro-package, and is pin-to-pin compatible.
Table 1. Advantages of TMP112 versus TMP102
DEVICE
COMPATIBLE
INTERFACES
PACKAGE
SUPPLY
CURRENT
SUPPLY
VOLTAGE
(MIN)
SUPPLY
VOLTAGE
(MAX)
RESOLUTION
LOCAL SENSOR ACCURACY
(MAX)
SPECIFIED
CALIBRATION
DRIFT SLOPE
TMP112
I2C
SMBus
SOT563
1.2 × 1.6 × 0.6
10 µA
1.4 V
3.6 V
12 bit
0.0625°C
0.5°C: (0°C to 65°C)
1°C: (-40°C to 125°C)
Yes
TMP102
I2C
SMBus
SOT563
1.2 × 1.6 × 0.6
10 µA
1.4 V
3.6 V
12 bit
0.0625°C
2°C: (25°C to 85°C)
3°C: (-40°C to 125°C)
No
7.2 Functional Block Diagram
Temperature
SCL
GND
ALERT
1
2
3
Diode
Temp.
Sensor
Control
Logic
6
DS
A/D
Converter
Serial
Interface
5
OSC
Config.
and Temp.
Register
4
SDA
V+
ADD0
7.3 Feature Description
7.3.1 Digital Temperature Output
The digital output from each temperature measurement is stored in the read-only temperature register. The
temperature register of the TMP102 device is configured as a 12-bit, read-only register (configuration register EM
bit = 0, see the Extended Mode (EM) section), or as a 13-bit, read-only register (configuration register EM bit = 1)
that stores the output of the most recent conversion. Two bytes must be read to obtain data and are listed in
Table 8 and Table 9. Byte 1 is the most significant byte (MSB), followed by byte 2, the least significant byte
(LSB). The first 12 bits (13 bits in extended mode) are used to indicate temperature. The least significant byte
does not have to be read if that information is not needed. The data format for temperature is summarized in
Table 2 and Table 3. One LSB equals 0.0625°C. Negative numbers are represented in binary twos-complement
format. Following power-up or reset, the temperature register reads 0°C until the first conversion is complete. Bit
D0 of byte 2 indicates normal mode (EM bit = 0) or extended mode (EM bit = 1) , and can be used to distinguish
between the two temperature register data formats. The unused bits in the temperature register always read 0.
8
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
Feature Description (continued)
Table 2. 12-Bit Temperature Data Format (1)
(1)
TEMPERATURE (°C)
DIGITAL OUTPUT (BINARY)
HEX
128
0111 1111 1111
7FF
127.9375
0111 1111 1111
7FF
100
0110 0100 0000
640
80
0101 0000 0000
500
75
0100 1011 0000
4B0
50
0011 0010 0000
320
25
0001 1001 0000
190
0.25
0000 0000 0100
004
0
0000 0000 0000
000
–0.25
1111 1111 1100
FFC
–25
1110 0111 0000
E70
–55
1100 1001 0000
C90
The resolution for the Temp ADC in Internal Temperature mode is 0.0625°C/count.
Table 2 does not list all temperatures. Use the following rules to obtain the digital data format for a given
temperature or the temperature for a given digital data format.
To convert positive temperatures to a digital data format:
1. Divide the temperature by the resolution
2. Convert the result to binary code with a 12-bit, left-justified format, and MSB = 0 to denote a positive sign.
Example: (50°C) / (0.0625°C / LSB) = 800 = 320h = 0011 0010 0000
To convert a positive digital data format to temperature:
1. Convert the 12-bit, left-justified binary temperature result, with the MSB = 0 to denote a positive sign, to a
decimal number.
2. Multiply the decimal number by the resolution to obtain the positive temperature.
Example: 0011 0010 0000 = 320h = 800 × (0.0625°C / LSB) = 50°C
To convert negative temperatures to a digital data format:
1. Divide the absolute value of the temperature by the resolution, and convert the result to binary code with a
12-bit, left-justified format.
2. Generate the twos complement of the result by complementing the binary number and adding one. Denote a
negative number with MSB = 1.
Example: (|–25°C|) / (0.0625°C / LSB) = 400 = 190h = 0001 1001 0000
Two's complement format: 1110 0110 1111 + 1 = 1110 0111 0000
To convert a negative digital data format to temperature:
1. Generate the twos compliment of the 12-bit, left-justified binary number of the temperature result (with MSB
= 1, denoting negative temperature result) by complementing the binary number and adding one. This
represents the binary number of the absolute value of the temperature.
2. Convert to decimal number and multiply by the resolution to get the absolute temperature, then multiply by
–1 for the negative sign.
Example: 1110 0111 0000 has twos compliment of 0001 1001 0000 = 0001 1000 1111 + 1
Convert to temperature: 0001 1001 0000 = 190h = 400; 400 × (0.0625°C / LSB) = 25°C = (|–25°C|);
(|–25°C|) × (–1) = –25°C
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
9
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Table 3. 13-Bit Temperature Data Format
TEMPERATURE (°C)
DIGITAL OUTPUT (BINARY)
HEX
150
0 1001 0110 0000
0960
128
0 1000 0000 0000
0800
127.9375
0 0111 1111 1111
07FF
100
0 0110 0100 0000
0640
80
0 0101 0000 0000
0500
75
0 0100 1011 0000
04B0
50
0 0011 0010 0000
0320
25
0 0001 1001 0000
0190
0.25
0 0000 0000 0100
0004
0
0 0000 0000 0000
0000
–0.25
1 1111 1111 1100
1FFC
–25
1 1110 0111 0000
1E70
–55
1 1100 1001 0000
1C90
7.3.2 Serial Interface
The TMP102 device operates as a slave device only on the two-wire bus and SMBus. Connections to the bus
are made through the open-drain I/O lines, SDA and SCL. The SDA and SCL pins feature integrated spike
suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP102
device supports the transmission protocol for both fast (1 kHz to 400 kHz) and high-speed (1 kHz to 2.85 MHz)
modes. All data bytes are transmitted MSB first.
7.3.3 Bus Overview
The device that initiates the transfer is called a master, and the devices controlled by the master are called
slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus
access, and generates the START and STOP conditions.
To address a specific device, a START condition is initiated, indicated by pulling the data-line (SDA) from a high
to low logic level when SCL is high. All slaves on the bus shift in the slave address byte on the rising edge of the
clock, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the
slave being addressed responds to the master by generating an acknowledge and by pulling SDA pin low.
A data transfer is then initiated and sent over eight clock pulses followed by an acknowledge bit. During the data
transfer the SDA pin must remain stable when SCL is high, because any change in SDA pin when SCL pin is
high is interpreted as a START signal or STOP signal.
When all data have been transferred, the master generates a STOP condition indicated by pulling SDA pin from
low to high, when the SCL pin is high.
7.3.4 Serial Bus Address
To communicate with the TMP102, the master must first address slave devices via a slave address byte. The
slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or
write operation.
The TMP102 features an address pin to allow up to four devices to be addressed on a single bus. Table 4
describes the pin logic levels used to properly connect up to four devices.
10
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
Table 4. Address Pin and Slave Addresses
DEVICE TWO-WIRE ADDRESS
A0 PIN CONNECTION
1001000
Ground
1001001
V+
1001010
SDA
1001011
SCL
7.3.5 Writing and Reading Operation
Accessing a particular register on the TMP102 device is accomplished by writing the appropriate value to the
pointer register. The value for the pointer register is the first byte transferred after the slave address byte with the
R/W bit low. Every write operation to the TMP102 device requires a value for the pointer register (see Figure 8).
When reading from the TMP102 device, the last value stored in the pointer register by a write operation
determines which register is read by a read operation. To change the register pointer for a read operation, a new
value must be written to the pointer register. This action is accomplished by issuing a slave address byte with the
R/W bit low, followed by the pointer register byte. No additional data are required. The master then generates a
START condition and sends the slave address byte with the R/W bit high to initiate the read command. See
Figure 7 for details of this sequence. If repeated reads from the same register are desired, continually sending
the Pointer Register bytes is not necessary because the TMP102 remembers the Pointer Register value until it is
changed by the next write operation.
Register bytes are sent with the most significant byte first, followed by the least significant byte.
7.3.6 Slave Mode Operations
The TMP102 can operate as a slave receiver or slave transmitter. As a slave device, the TMP102 never drives
the SCL line.
7.3.6.1 Slave Receiver Mode
The first byte transmitted by the master is the slave address, with the R/W bit low. The TMP102 then
acknowledges reception of a valid address. The next byte transmitted by the master is the pointer register. The
TMP102 then acknowledges reception of the pointer register byte. The next byte or bytes are written to the
register addressed by the pointer register. The TMP102 acknowledges reception of each data byte. The master
can terminate data transfer by generating a START or STOP condition..
7.3.6.2 Slave Transmitter Mode
The first byte transmitted by the master is the slave address, with the R/W bit high. The slave acknowledges
reception of a valid slave address. The next byte is transmitted by the slave and is the most significant byte of
the register indicated by the pointer register. The master acknowledges reception of the data byte. The next byte
transmitted by the slave is the least significant byte. The master acknowledges reception of the data byte. The
master terminates data transfer by generating a Not-Acknowledge on reception of any data byte, or generating a
START or STOP condition.
7.3.7 SMBus Alert Function
The TMP102 device supports the SMBus alert function. When the TMP102 device operates in Interrupt Mode
(TM = 1), the ALERT pin can be connected as an SMBus alert signal. When a master senses that an ALERT
condition is present on the ALERT line, the master sends an SMBus alert command (0001 1001) to the bus. If
the ALERT pin is active, the device acknowledges the SMBus alert command and responds by returning the
slave address on the SDA line. The eighth bit (LSB) of the slave address byte indicates if the ALERT condition
was caused by the temperature exceeding THIGH or falling below TLOW. For POL = 0, the LSB is low if the
temperature is greater than or equal to THIGH; this bit is high if the temperature is less than TLOW. The polarity of
this bit is inverted if POL = 1. See Figure 10 for details of this sequence.
If multiple devices on the bus respond to the SMBus alert command, arbitration during the slave address portion
of the SMBus alert command determines which device clears the ALERT status. The device with the lowest twowire address wins the arbitration. If the TMP102 device wins the arbitration, its ALERT pin inactivates at the
completion of the SMBus alert command. If the TMP102 device loses the arbitration, its ALERT pin remains
active.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
11
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
7.3.8 General Call
The TMP102 device responds to a two-wire general call address (000 0000) if the eighth bit is 0. The device
acknowledges the general call address and responds to commands in the second byte. If the second byte is
0000 0110, the TMP102 device internal registers are reset to power-up values. The TMP102 device does not
support the general address acquire command.
7.3.9 High-Speed (HS) Mode
In order for the two-wire bus to operate at frequencies above 400 kHz, the master device must issue an HSMode master code (0000 1xxx) as the first byte after a START condition to switch the bus to high-speed
operation. The TMP102 device does not acknowledge this byte, but switches the input filters on SDA and SCL
and the output filters on SDA to operate in HS-mode, allowing transfers of up to 2.85 MHz. After the HS-Mode
master code has been issued, the master transmits a two-wire slave address to initiate a data transfer operation.
The bus continues to operate in HS-Mode until a STOP condition occurs on the bus. Upon receiving the STOP
condition, the TMP102 device switches the input and output filters back to fast-mode operation..
7.3.10 Timeout Function
The TMP102 device resets the serial interface if SCL is held low for 30 ms (typ) between a start and stop
condition. The TMP102 device releases the SDA line if the SCL pin is pulled low and waits for a start condition
from the host controller. To avoid activating the time-out function, maintaining a communication speed of at least
1 kHz for SCL operating frequency is necessary..
7.3.11 Timing Diagrams
The TMP102 device is two-wire, SMBus, and I2C-interface compatible. Figure 7, Figure 8, Figure 9, and
Figure 10 list the various operations on the TMP102 device. Parameters for Figure 7 are defined in the Timing
Requirements table. The bus definitions are defined as follows:
Acknowledge Each receiving device, when addressed, is obliged to generate an acknowledge bit. A device that
acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that
the SDA line is stable low during the high period of the Acknowledge clock pulse. Setup and hold
times must be taken into account. On a master receive, the termination of the data transfer can be
signaled by the master generating a not-acknowledge (1) on the last byte that has been transmitted
by the slave.
Bus Idle
Both SDA and SCL lines remain high.
Data Transfer The number of data bytes transferred between a START and a STOP condition is not limited and
is determined by the master device. The TMP102 device can also be used for single byte updates.
To update only the MS byte, terminate the communication by issuing a START or STOP
communication on the bus.
Start Data Transfer A change in the state of the SDA line, from high to low, when the SCL line is high, defines a
START condition. Each data transfer is initiated with a START condition.
Stop Data Transfer A change in the state of the SDA line from low to high when the SCL line is high defines a
STOP condition. Each data transfer is terminated with a repeated START or STOP condition.
t(LOW)
tFC
t(HDSTA)
tRC
SCL
t(HDSTA)
t(HIGH)
t(HDDAT)
t(SUSTO)
t(SUSTA)
t(SUDAT)
SDA
t(BUF)
P
tRD
S
tFD
S
P
Figure 7. Two-Wire Timing Diagram
12
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
1
9
1
9
SCL
¼
1
SDA
0
0
1
0
A1(1)
A0(1)
0
R/W
Start By
Master
0
0
0
0
0
P1
P0
ACK By
Device
¼
ACK By
Device
Frame 2 Pointer Register Byte
Frame 1 Two-Wire Slave Address Byte
1
9
1
9
SCL
(Continued)
SDA
(Continued)
D6
D7
D5
D4
D3
D2
D1
D7
D0
D6
D5
D4
D3
D2
D1
D0
ACK By
Device
ACK By
Device
Stop By
Master
Frame 4 Data Byte 2
Frame 3 Data Byte 1
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
Figure 8. Two-Wire Timing Diagram for Write Word Format
1
9
1
9
SCL
¼
SDA
1
0
0
1
0
A1
(1)
A0
(1)
R/W
Start By
Master
0
0
0
0
0
0
P1
P0
ACK By
Device
ACK By
Device
Frame 1 Two-Wire Slave Address Byte
Stop By
Master
Frame 2 Pointer Register Byte
1
9
1
9
SCL
(Continued)
¼
SDA
(Continued)
1
0
0
1
0
A1
(1)
A0
(1)
D7
R/W
Start By
Master
D6
D5
ACK By
Device
Frame 3 Two-Wire Slave Address Byte
1
D4
D3
D2
D1
D0
From
Device
¼
ACK By
Master
(2)
Frame 4 Data Byte 1 Read Register
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D0
ACK By
From
Device
Master
(3)
Stop By
Master
Frame 5 Data Byte 2 Read Register
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
(2) Master should leave SDA high to terminate a single-byte read operation.
(3) Master should leave SDA high to terminate a two-byte read operation.
Figure 9. Two-Wire Timing Diagram for Read Word Format
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
13
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
ALERT
1
9
1
9
SCL
SDA
0
0
0
1
1
0
0
1
R/W
Start By
Master
0
0
1
A1
ACK By
Device
Frame 1 SMBus ALERT Response Address Byte
A0
Status
From
Device
NACK By
Master
Stop By
Master
Frame 2 Slave Address From Device
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
Figure 10. Timing Diagram for SMBus Alert
7.4 Device Functional Modes
7.4.1 Continuos-Conversion Mode
The default mode of the TMP102 device is continuos conversion mode. During continuos-conversion mode, the
ADC performs continuos temperature conversions and stores each results to the temperature register,
overwriting the result from the previous conversion. The conversion rate bits, CR1 and CR0, configure the
TMP102 device for conversion rates of 0.25 Hz, 1 Hz, 4 Hz, or 8 Hz. The default rate is 4 Hz. The TMP102
device has a typical conversion time of 26 ms. To achieve different conversion rates, the TMP102 device makes
a conversion and then powers down to wait for the appropriate delay set by CR1 and CR0. Table 5 lists the
settings for CR1 and CR0.
Table 5. Conversion Rate Settings
CR1
CR0
CONVERSION RATE
0
0
0.25 Hz
0
1
1 Hz
1
0
4 Hz (default)
1
1
8 Hz
After power-up or general-call reset, the TMP102 immediately starts a conversion, as shown in Figure 11. The
first result is available after 26 ms (typical). The active quiescent current during conversion is 40 μA (typical at
+27°C). The quiescent current during delay is 2.2 μA (typical at +27°C).
Delay
(1)
26ms
26ms
Startup
(1)
Start of
Conversion
Delay is set by CR1 and CR0.
Figure 11. Conversion Start
7.4.2 Extended Mode (EM)
The Extended-Mode bit configures the device for Normal mode operation (EM = 0) or Extended mode operation
(EM = 1). In Normal mode, the Temperature Register and high- and low-limit registers use a 12-bit data format.
Normal mode is used to make the TMP102 device compatible with the TMP75 device.
Extended mode (EM = 1) allows measurement of temperatures above 128°C by configuring the Temperature
Register, and high- and low-limit registers for 13-bit data format.
14
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
7.4.3 Shutdown Mode (SD)
The Shutdown-mode bit saves maximum power by shutting down all device circuitry other than the serial
interface, reducing current consumption to typically less than 0.5 μA. Shutdown mode enables when the SD bit is
1; the device shuts down when current conversion is completed. When SD is equal to 0, the device maintains a
continuous conversion state.
7.4.4 One-Shot/Conversion Ready (OS)
The TMP102 device features a one-shot temperature measurement mode. When the device is in Shutdown
Mode, writing a 1 to the OS bit starts a single temperature conversion. During the conversion, the OS bit reads
'0'. The device returns to the shutdown state at the completion of the single conversion. After the conversion, the
OS bit reads 1. This feature reduces power consumption in the TMP102 device when continuous temperature
monitoring is not required.
As a result of the short conversion time, the TMP102 device achieves a higher conversion rate. A single
conversion typically takes 26 ms and a read can take place in less than 20 μs. When using One-Shot Mode, 30
or more conversions per second are possible.
7.4.5 Thermostat Mode (TM)
The thermostat-mode bit indicates to the device whether to operate in comparator mode (TM = 0) or Interrupt
mode (TM = 1).
7.4.5.1 Comparator Mode (TM = 0)
In Comparator mode (TM = 0), the Alert pin is activated when the temperature equals or exceeds the value in the
T(HIGH) register and remains active until the temperature falls below the value in the T(LOW)register. For more
information on the comparator mode, see the High- and Low-Limit Registers section.
7.4.5.2 Interrupt Mode (TM = 1)
In Interrupt mode (TM = 1), the Alert pin is activated when the temperature exceeds T(HIGH) or goes below T(LOW)
registers. The Alert pin is cleared when the host controller reads the temperature register. For more information
on the interrupt mode, see the High- and Low-Limit Registers section.
7.5 Programming
7.5.1 Pointer Register
Figure 12 illustrates the internal register structure of the TMP102 device. The 8-bit Pointer Register of the device
is used to address a given data register. The Pointer Register uses the two least-significant bytes (LSBs) (see
Table 15 and Table 16) to identify which of the data registers must respond to a read or write command. Table 6
identifies the bits of the Pointer Register byte. During a write command, P2 through P7 must always be '0'.
Table 7 describes the pointer address of the registers available in the TMP102 device. The power-up reset value
of P1 and P0 is 00. By default, the TMP102 device reads the temperature on power up.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
15
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Programming (continued)
Pointer
Register
Temperature
Register
SCL
Configuration
Register
I/O
Control
Interface
TLOW
Register
SDA
THIGH
Register
Figure 12. Internal Register Structure
Table 6. Pointer Register Byte
P7
P6
P5
0
0
0
P4
P3
P2
0
0
0
P1
P0
Register Bits
Table 7. Pointer Addresses
P1
P0
REGISTER
0
0
Temperature Register (Read Only)
0
1
Configuration Register (Read/Write)
1
0
TLOW Register (Read/Write)
1
1
THIGH Register (Read/Write)
7.5.2 Temperature Register
The Temperature Register of the TMP102 is configured as a 12-bit, read-only register (Configuration Register
EM bit = 0, see the Extended Mode section), or as a 13-bit, read-only register (Configuration Register EM bit = 1)
that stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described
in Table 8 and Table 9. Note that byte 1 is the most significant byte, followed by byte 2, the least significant byte.
The first 12 bits (13 bits in Extended mode) are used to indicate temperature. The least significant byte does not
have to be read if that information is not needed.
Table 8. Byte 1 of Temperature Register (1)
(1)
16
D7
D6
D5
D4
D3
D2
D1
T11
T10
T9
T8
T7
T6
T5
D0
T4
(T12)
(T11)
(T10)
(T9)
(T8)
(T7)
(T6)
(T5)
Extended mode 13-bit configuration shown in parenthesis.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
Table 9. Byte 2 of Temperature Register (1)
(1)
D7
D6
D5
D4
D3
D2
D1
D0
T3
T2
T1
T0
0
0
0
0
(T4)
(T3)
(T2)
(T1)
(T0)
(0)
(0)
(1)
Extended mode 13-bit configuration shown in parenthesis.
7.5.3 Configuration Register
The Configuration Register is a 16-bit read/write register used to store bits that control the operational modes of
the temperature sensor. Read/write operations are performed MSB first. Table 10 and Table 11 list the format
and the power-up or reset value of the configuration register. For compatibility, Table 10 and Table 11
correspond to the configuration register in the TMP75 device and TMP275 device (for more information see the
device data sheets, SBOS288 and SBOS363, respectively). All registers are updated byte by byte.
Table 10. Byte 1 of Configuration and Power-Up or Reset Format
D7
D6
D5
D4
D3
D2
D1
D0
OS
R1
R0
F1
F0
POL
TM
SD
0
1
1
0
0
0
0
0
Table 11. Byte 2 of Configuration and Power-Up or Reset Format
D7
D6
D5
D4
D3
D2
D1
D0
CR1
CR0
AL
EM
0
0
0
0
1
0
1
0
0
0
0
0
7.5.3.1 Shutdown Mode (SD)
The Shutdown-mode bit saves maximum power by shutting down all device circuitry other than the serial
interface, reducing current consumption to typically less than 0.5 μA. Shutdown mode enables when the SD bit is
1; the device shuts down when current conversion is completed. When SD is equal to 0, the device maintains a
continuous conversion state
7.5.3.2 Thermostat Mode (TM)
The Thermostat mode bit indicates to the device whether to operate in Comparator mode (TM = 0) or Interrupt
mode (TM = 1). For more information on comparator and interrupt modes, see the High- and Low-Limit Registers
section.
7.5.3.3 Polarity (POL)
The polarity bit allows the user to adjust the polarity of the ALERT pin output. If the POL bit is set to 0 (default),
the ALERT pin becomes active low. When the POL bit is set to 1, the ALERT pin becomes active high and the
state of the ALERT pin is inverted. The operation of the ALERT pin in various modes is illustrated in Figure 13.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
17
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
THIGH
Measured
Temperature
TLOW
Device ALERT PIN
(Comparator Mode)
POL = 0
Device ALERT PIN
(Interrupt Mode)
POL = 0
Device ALERT PIN
(Comparator Mode)
POL = 1
Device ALERT PIN
(Interrupt Mode)
POL = 1
Read
Read
Read
Time
Figure 13. Output Transfer Function Diagrams
7.5.3.4 Fault Queue (F1/F0)
A fault condition exists when the measured temperature exceeds the user-defined limits set in the THIGH and
TLOW registers. Additionally, the number of fault conditions required to generate an alert may be programmed
using the fault queue. The fault queue is provided to prevent a false alert as a result of environmental noise. The
fault queue requires consecutive fault measurements in order to trigger the alert function. Table 12 defines the
number of measured faults that may be programmed to trigger an alert condition in the device. For THIGH and
TLOW register format and byte order, see the High- and Low-Limit Registers section.
Table 12. TMP102 Fault Settings
F1
F0
CONSECUTIVE FAULTS
0
0
1
0
1
2
1
0
4
1
1
6
7.5.3.5 Converter Resolution (R1/R0)
The converter resolution bits, R1 and R0, are read-only bits. The TMP102 converter resolution is set at device
start-up to 11 which sets the temperature register to a 12 bit-resolution.
7.5.3.6 One-Shot (OS)
When the device is in Shutdown Mode, writing a 1 to the OS bit starts a single temperature conversion. During
the conversion, the OS bit reads '0'. The device returns to the shutdown state at the completion of the single
conversion. For more information on the one-shot conversion mode, see the One-Shot/Conversion Ready (OS)
section.
7.5.3.7 EM Bit
The Extended-Mode bit configures the device for Normal Mode operation (EM = 0) or Extended Mode operation
(EM = 1). In normal mode, the temperature register, high-limit register, and low-limit register use a 12-bit data
format. For more information on the extended mode, see the Extended Mode (EM) section.
18
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
7.5.3.8 Alert (AL Bit)
The AL bit is a read-only function. Reading the AL bit provides information about the comparator mode status.
The state of the POL bit inverts the polarity of data returned from the AL bit. When the POL bit equals 0, the AL
bit reads as 1 until the temperature equals or exceeds T(HIGH) for the programmed number of consecutive faults,
causing the AL bit to read as 0. The AL bit continues to read as 0 until the temperature falls below T(LOW) for the
programmed number of consecutive faults, when it again reads as 1. The status of the TM bit does not affect the
status of the AL bit..
7.5.3.9 Conversion Rate (CR)
The conversion rate bits, CR1 and CR0, configure the TMP102 device for conversion rates of 0.25 Hz, 1 Hz, 4
Hz, or 8 Hz. The default rate is 4 Hz. For more information on the conversion rate bits, see Table 5.
7.5.4 High- and Low-Limit Registers
The temperature limits are stored in the T(LOW) and T(HIGH) registers in the same format as the temperature result,
and their values are compared to the temperature result on every conversion. The outcome of the comparison
drives the behavior of the ALERT pin, which operates as a comparator output or an interrupt, and is set by the
TM bit in the configuration register.
In Comparator mode (TM = 0), the ALERT pin becomes active when the temperature equals or exceeds the
value in THIGH and generates a consecutive number of faults according to fault bits F1 and F0. The ALERT pin
remains active until the temperature falls below the indicated TLOW value for the same number of faults.
In Interrupt mode (TM = 1), the ALERT pin becomes active when the temperature equals or exceeds the value in
THIGH for a consecutive number of fault conditions (as shown in Table 5). The ALERT pin remains active until a
read operation of any register occurs, or the device successfully responds to the SMBus Alert Response
address. The ALERT pin will also be cleared if the device is placed in Shutdown mode. When the ALERT pin is
cleared, it becomes active again only when temperature falls below TLOW, and remains active until cleared by a
read operation of any register or a successful response to the SMBus Alert Response address. When the ALERT
pin is cleared, the above cycle repeats, with the ALERT pin becoming active when the temperature equals or
exceeds THIGH. The ALERT pin can also be cleared by resetting the device with the General Call Reset
command. This action also clears the state of the internal registers in the device, returning the device to
Comparator mode (TM = 0).
Both operational modes are represented in Figure 13. Table 13 through Table 16 describe the format for the
THIGH and TLOW registers. Note that the most significant byte is sent first, followed by the least significant byte.
Power-up reset values for THIGH and TLOW are: THIGH = +80°C and TLOW = +75°C. The format of the data for THIGH
and TLOW is the same as for the Temperature Register.
Table 13. Byte 1 Temperature Register
(1)
HIGH
D7
D6
D5
D4
D3
D2
D1
D0
H11
H10
H9
H8
H7
H6
H5
H4
(H12)
(H11)
(H10)
(H9)
(H8)
(H7)
(H6)
(H5)
Extended mode 13-bit configuration shown in parenthesis.
Table 14. Byte 2 Temperature Register
HIGH
D7
D6
D5
D4
D3
D2
D1
D0
H3
H2
H1
H0
0
0
0
0
(H4)
(H3)
(H2)
(H1)
(H0)
(0)
(0)
(0)
Table 15. Byte 1 Temperature Register
(1)
(1)
LOW
(1)
D7
D6
D5
D4
D3
D2
D1
D0
L11
L10
L9
L8
L7
L6
L5
L4
(L12)
(L11)
(L10)
(L9)
(L8)
(L7)
(L6)
(L5)
Extended mode 13-bit configuration shown in parenthesis.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
19
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Table 16. Byte 2 Temperature Register
20
LOW
D7
D6
D5
D4
D3
D2
D1
D0
L3
L2
L1
L0
0
0
0
0
(L4)
(L3)
(L2)
(L1)
(L0)
(0)
(0)
(0)
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
8 Application and Implementation
NOTE
Information in the following applications sections is not part of the TI component
specification, and TI does not warrant its accuracy or completeness. TI’s customers are
responsible for determining suitability of components for their purposes. Customers should
validate and test their design implementation to confirm system functionality.
8.1 Application Information
The TMP102 device is used to measure the PCB temperature of the board location where the device is mounted.
The programmable address options allow up to four locations on the board to be monitored on a single serial
bus.
8.2 Typical Application
Supply Voltage
1.4 V to 3.6 V
Supply Bypass
Capacitor
Pullup Resistors
0.01 µF
5k
TMP102
Two-Wire
Host Controller
1
2
3
SCL
SDA
GND
V+
ALERT
6
5
4
ADD0
Figure 14. Typical Connections
8.2.1 Design Requirements
The TMP102 device requires pullup resistors on the SCL, SDA, and ALERT pins. The recommended value for
the pullup resistors is 5-kΩ. In some applications the pullup resistor can be lower or higher than 5 kΩ but must
not exceed 3 mA of current on any of those pins. A 0.01-μF bypass capacitor on the supply is recommended as
shown in Figure 14. The SCL and SDA lines can be pulled up to a supply that is equal to or higher than V+
through the pullup resistors. To configure one of four different addresses on the bus, connect the ADD0 pin to
either the GND, V+, SDA, or SCL pin.
8.2.2 Detailed Design Procedure
Place the TMP102 device in close proximity to the heat source that must be monitored, with a proper layout for
good thermal coupling. This placement ensures that temperature changes are captured within the shortest
possible time interval. To maintain accuracy in applications that require air or surface temperature measurement,
care must be taken to isolate the package and leads from ambient air temperature. A thermally-conductive
adhesive is helpful in achieving accurate surface temperature measurement.
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
21
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
Typical Application (continued)
The TMP102 device is a very low-power device and generates very low noise on the supply bus. Applying an RC
filter to the V+ pin of the TMP102 device can further reduce any noise that the TMP102 device might propagate
to other components. R(F) in Figure 15 must be less than 5 kΩ and C(F) must be greater than 10 nF.
Supply Voltage
R(F) ≤ 5 kΩ
Device
SCL
SDA
GND
V+
ALERT
C(F) ≥ 10 nF
ADD0
Figure 15. Noise Reduction Techniques
8.2.3 Application Curve
Figure 16 shows the step response of the TMP102 device to a submersion in an oil bath of 100ºC from room
temperature (27ºC). The time-constant, or the time for the output to reach 63% of the input step, is 0.8 s. The
time-constant result depends on the printed circuit board (PCB) that the TMP102 device is mounted. For this test,
the TMP102 device was soldered to a two-layer PCB that measured 0.375 inch × 0.437 inch.
Temperature (qC)
space
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
-1
1
3
5
7
9
11
Time (s)
13
15
17
19
Figure 16. Temperature Step Response
22
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
TMP102
www.ti.com
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
9 Power Supply Recommendations
The TMP102 device operates with power supply in the range of 1.4 to 3.6 V. The device is optimized for
operation at 3.3-V supply but can measure temperature accurately in the full supply range.
A power-supply bypass capacitor is required for proper operation. Place this capacitor as close as possible to the
supply and ground pins of the device. A typical value for this supply bypass capacitor is 0.01 μF. Applications
with noisy or high-impedance power supplies may require additional decoupling capacitors to reject power-supply
noise.
10 Layout
10.1 Layout Guidelines
Place the power-supply bypass capacitor as close as possible to the supply and ground pins. The recommended
value of this bypass capacitor is 0.01 μF. Additional decoupling capacitance can be added to compensate for
noisy or high-impedance power supplies. Pull up the open-drain output pins (SDA , SCL and ALERT) through 5kΩ pullup resistors.
10.2 Layout Example
Via to Power or
Ground Plane
Via to Internal Layer
Pullup Resistors
SCL
SDA
GND
V+
Supply Voltage
ALERT
ADD0
Supply Bypass
Capacitor
Ground Plane for
Thermal Coupling
to Heat Source
Serial Bus Traces
Heat Source
Figure 17. TMP102 Layout Example
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
23
TMP102
SBOS397H – AUGUST 2007 – REVISED DECEMBER 2018
www.ti.com
11 Device and Documentation Support
11.1 Documentation Support
11.1.1 Related Documentation
For related documentation see the following:
• TMP175, TMP75 Data Sheet, SBOS288
• TMP275 Data Sheet, SBOS363
• Capacitive Touch Operated Automotive LED Dome Light with Haptics Feedback Design Guide
11.2 Receiving Notification of Documentation Updates
To receive notification of documentation updates, navigate to the device product folder on ti.com. In the upper
right corner, click on Alert me to register and receive a weekly digest of any product information that has
changed. For change details, review the revision history included in any revised document.
11.3 Community Resources
The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective
contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of
Use.
TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration
among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help
solve problems with fellow engineers.
Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and
contact information for technical support.
11.4 Trademarks
E2E is a trademark of Texas Instruments.
SMBus is a trademark of Intel, Inc.
All other trademarks are the property of their respective owners.
11.5 Electrostatic Discharge Caution
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
11.6 Glossary
SLYZ022 — TI Glossary.
This glossary lists and explains terms, acronyms, and definitions.
12 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the most
current data available for the designated devices. This data is subject to change without notice and revision of
this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
24
Submit Documentation Feedback
Copyright © 2007–2018, Texas Instruments Incorporated
Product Folder Links: TMP102
PACKAGE OPTION ADDENDUM
www.ti.com
1-Dec-2021
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
Device Marking
(3)
(4/5)
(6)
TMP102AIDRLR
ACTIVE
SOT-5X3
DRL
6
4000
RoHS & Green NIPDAU | NIPDAUAG
Level-1-260C-UNLIM
-40 to 125
CBZ
TMP102AIDRLRG4
ACTIVE
SOT-5X3
DRL
6
4000
RoHS & Green
Level-1-260C-UNLIM
-40 to 125
CBZ
TMP102AIDRLT
ACTIVE
SOT-5X3
DRL
6
250
RoHS & Green NIPDAU | NIPDAUAG
Level-1-260C-UNLIM
-40 to 125
CBZ
TMP102AIDRLTG4
ACTIVE
SOT-5X3
DRL
6
250
RoHS & Green
Level-1-260C-UNLIM
-40 to 125
CBZ
NIPDAU
NIPDAU
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of