0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TMP461AIRUNT-S

TMP461AIRUNT-S

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    WFQFN10

  • 描述:

    TEMPERATURE SENSOR

  • 数据手册
  • 价格&库存
TMP461AIRUNT-S 数据手册
Product Folder Sample & Buy Support & Community Tools & Software Technical Documents TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 TMP461 High-Accuracy Remote and Local Temperature Sensor with Pin-Programmable Bus Address 1 Features 3 Description • The TMP461 device is a high-accuracy, low-power remote temperature sensor monitor with a built-in local temperature sensor. The remote temperature sensors are typically low-cost discrete NPN or PNP transistors, or substrate thermal transistors or diodes that are integral parts of microprocessors, microcontrollers, or field-programmable gate arrays (FPGAs). Temperature is represented as a 12-bit digital code for both local and remote sensors, giving a resolution of 0.0625°C. The two-wire serial interface accepts the SMBus communication protocol with up to nine different pin-programmable addresses. 1 • • • • • • • • • • Remote Diode Temperature Sensor Accuracy: ±0.75°C Local Temperature Sensor Accuracy: ±1°C Resolution for Local and Remote Channels: 0.0625°C Supply and Logic Voltage Range: 1.7 V to 3.6 V 35-µA Operating Current (1 SPS), 3-µA Shutdown Current Series Resistance Cancellation η-Factor and Offset Correction Programmable Digital Filter Diode Fault Detection Two-Wire and SMBus™ Serial Interface Compatible with Pin-Programmable Address 10-Lead WQFN Package Advanced features [such as series resistance cancellation, programmable nonideality factor (ηfactor), programmable offset, programmable temperature limits, and a programmable digital filter] are combined to provide a robust thermal monitoring solution with improved accuracy and noise immunity. The TMP461 is ideal for multi-location, high-accuracy temperature measurements in a variety of communication, computing, instrumentation, and industrial applications. The device is specified for operation over a supply voltage range of 1.7 V to 3.6 V, and a temperature range of –40°C to 125°C. 2 Applications • • • • • • • • Processor Temperature Monitoring Telecommunication Equipment Servers and Personal Computers Precision Instruments Test Equipment Smart Batteries Embedded Applications LED Lighting Thermal Control Device Information(1) PART NUMBER TMP461 PACKAGE WQFN (10) BODY SIZE (NOM) 2.00 mm × 2.00 mm (1) For all available packages, see the orderable addendum at the end of the datasheet. 4 Simplified Block Diagram 1.7 V to 3.6 V 1.7 V to 3.6 V 10 A1 Processor or ASIC 1 9 SCL V+ 2 Built-In Thermal Transistor, Diode 3 8 D+ TMP461 D- ALERT/THERM2 4 SDA GND THERM 7 SMBus Controller 6 A0 5 Overtemperature Shutdown 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com Table of Contents 1 2 3 4 5 6 7 8 Features .................................................................. Applications ........................................................... Description ............................................................. Simplified Block Diagram ..................................... Revision History..................................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 1 2 3 4 7.1 7.2 7.3 7.4 7.5 7.6 7.7 4 4 4 4 5 6 7 Absolute Maximum Ratings ...................................... ESD Ratings.............................................................. Recommended Operating Conditions....................... Thermal Information .................................................. Electrical Characteristics........................................... Two-Wire Timing Requirements ............................... Typical Characteristics .............................................. Detailed Description .............................................. 9 8.1 Overview ................................................................... 9 8.2 Functional Block Diagram ......................................... 9 8.3 Feature Description................................................. 10 8.4 Device Functional Modes........................................ 13 8.5 Programming........................................................... 14 8.6 Register Map........................................................... 17 9 Application and Implementation ........................ 23 9.1 Application Information............................................ 23 9.2 Typical Application .................................................. 23 10 Power Supply Recommendations ..................... 26 11 Layout................................................................... 27 11.1 Layout Guidelines ................................................. 27 11.2 Layout Example .................................................... 28 12 Device and Documentation Support ................. 29 12.1 12.2 12.3 12.4 12.5 Receiving Notification of Documentation Updates Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 29 29 29 29 29 13 Mechanical, Packaging, and Orderable Information ........................................................... 29 5 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision A (July 2015) to Revision B Page • Added formating of limits - moved negative limits from max column to min column for all temperature accuracy limits. ..... 5 • Added minimum and maximum over temperature limits for all Remote sensor source current specifications. .................... 5 Changes from Original (June 2015) to Revision A • 2 Page Released to production .......................................................................................................................................................... 1 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 6 Pin Configuration and Functions RUN Package 10-Pin WQFN Top View A1 V+ 1 D+ 10 9 SCL 2 8 SDA D- 3 7 ALERT/THERM2 THERM 4 6 GND 5 A0 Pin Functions PIN NAME NO. TYPE DESCRIPTION A0 5 Digital input Address select. Connect to GND, V+, or leave floating. A1 10 Digital input Address select. Connect to GND, V+, or leave floating. ALERT/THERM2 7 Digital output Interrupt or SMBus alert output. Can be configured as a second THERM output. Open-drain; requires a pullup resistor to a voltage between 1.7 V and 3.6 V. D– 3 Analog input Negative connection to remote temperature sensor D+ 2 Analog input Positive connection to remote temperature sensor GND 6 Ground SCL 9 Digital input SDA 8 THERM 4 Digital output Thermal shutdown or fan-control pin. Open-drain; requires a pullup resistor to a voltage between 1.7 V and 3.6 V. V+ 1 Power supply Positive supply voltage, 1.7 V to 3.6 V Supply ground connection Serial clock line for SMBus. Input; requires a pullup resistor to a voltage between 1.7 V and 3.6 V if driven by an open-drain output. Bidirectional digital Serial data line for SMBus. Open-drain; requires a pullup resistor to a voltage between 1.7 V and 3.6 V. input-output Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 3 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 7 Specifications 7.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted) (1) Power supply Input voltage MIN MAX UNIT V+ –0.3 6 V THERM, ALERT/THERM2, SDA and SCL only –0.3 6 D+, A0, A1 –0.3 (V+) + 0.3 D– only –0.3 0.3 10 mA –55 150 °C 150 °C 150 °C Input current Operating temperature Junction temperature (TJ max) Storage temperature, Tstg (1) –60 V Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. 7.2 ESD Ratings VALUE V(ESD) (1) (2) Electrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) ±2000 Charged device model (CDM), JEDEC specification JESD22-C101 (2) ±1000 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. 7.3 Recommended Operating Conditions over operating free-air temperature range (unless otherwise noted) MIN NOM MAX V+ Supply voltage 1.7 3.3 3.6 UNIT V TA Operating free-air temperature –40 125 °C 7.4 Thermal Information TMP461 THERMAL METRIC (1) RUN (WQFN) UNIT 10 PINS RθJA Junction-to-ambient thermal resistance 123.1 °C/W RθJC(top) Junction-to-case (top) thermal resistance 60.1 °C/W RθJB Junction-to-board thermal resistance 78.1 °C/W ψJT Junction-to-top characterization parameter 4.6 °C/W ψJB Junction-to-board characterization parameter 78.1 °C/W (1) 4 For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 7.5 Electrical Characteristics At TA = –40°C to 125°C and V+ = 1.7 V to 3.6 V, unless otherwise noted. PARAMETER CONDITIONS MIN TYP MAX TA = –10°C to 100°C, V+ = 1.7 V to 3.6 V -1 ±0.125 +1 TA = –40°C to 125°C, V+ = 1.7 V to 3.6 V -1.25 ±0.5 +1.25 TA = 0°C to 100°C, TD = –55°C to 150°C, V+ = 1.7 V to 3.6 V -0.75 ±0.125 + 0.75 -1.5 ±0.5 +1.5 -0.25 ±0.1 +0.25 UNIT TEMPERATURE MEASUREMENT TALOCAL TAREMOTE Local temperature sensor accuracy Remote temperature sensor accuracy Temperature sensor error versus supply (local or remote) TA = –40°C to 125°C, TD = –55°C to 150°C, V+ = 1.7 V to 3.6 V V+ = 1.7 V to 3.6 V °C Temperature resolution (local and remote) ADC conversion time 0.0625 One-shot mode, per channel (local or remote) 15 ADC resolution Medium 88 Series resistance 1 kΩ (max) Low η Remote transistor ideality factor 120 17 ms Bits 152 33 45 57 5.5 7.5 9.5 TMP461 optimized ideality factor °C/V °C 12 High Remote sensor source current °C µA 1.008 SERIAL INTERFACE VIH High-level input voltage VIL Low-level input voltage 1.4 Hysteresis 200 SDA output-low sink current VOL IO = –6 mA Serial bus input leakage current 0 V ≤ VIN ≤ 3.6 V mA 0.15 –1 0.4 V 1 μA pF SCL 3 6 SDA 4.6 9 Serial bus clock frequency 0.001 Serial bus timeout 20 V mV 6 Low-level output voltage Serial bus input capacitance V 0.45 2.17 25 30 pF MHz ms DIGITAL INPUTS (A0, A1) VIH High-level input voltage 0.9(V+) (V+) + 0.3 VIL Low-level input voltage –0.3 0.1(V+) V –1 1 μA 2.5 5 pF 0.15 0.4 V 1 μA 3.6 V Input leakage current 0 V ≤ VIN ≤ 3.6 V Input capacitance V DIGITAL OUTPUTS (THERM, ALERT/THERM2) Output-low sink current 6 VOL Low-level output voltage IO = –6 mA IOH High-level output leakage current VO = V+ mA POWER SUPPLY V+ IQ Specified supply voltage range Quiescent current 1.7 Active conversion, local sensor 240 375 Active conversion, remote sensor 400 600 15 35 3 8 Standby mode (between conversions) Shutdown mode, serial bus inactive Shutdown mode, serial bus active, fS = 400 kHz POR Power-on reset threshold 90 Shutdown mode, serial bus active, fS = 2.17 MHz 350 Rising edge 1.2 1.55 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 µA V 5 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 7.6 Two-Wire Timing Requirements At –40°C to 125°C and V+ = 1.7 V to 3.6 V, unless otherwise noted. FAST MODE HIGH-SPEED MODE MIN MAX MIN MAX UNIT 0.4 0.001 2.17 MHz f(SCL) SCL operating frequency 0.001 t(BUF) Bus free time between stop and start condition 1300 160 ns t(HDSTA) Hold time after repeated start condition. After this period, the first clock is generated. 600 160 ns t(SUSTA) Repeated start condition setup time 600 160 ns t(SUSTO) Stop condition setup time 600 160 t(HDDAT) Data hold time t(SUDAT) Data setup time t(LOW) 0 900 ns 0 150 ns 100 40 ns SCL clock low period 1300 320 ns t(HIGH) SCL clock high period 600 60 ns tF – SDA Data fall time 300 130 ns tF, tR – SCL Clock fall and rise time 300 40 ns tR Rise time for SCL ≤ 100 kHz t(LOW) 1000 tF tR ns t(HDSTA) SCL t(HDSTA) t(HIGH) t(HDDAT) t(SUSTO) t(SUSTA) t(SUDAT) SDA t(BUF) P S S P Figure 1. Two-Wire Timing Diagram 6 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 7.7 Typical Characteristics At TA = 25°C and V+ = 3.6 V, unless otherwise noted. 1 Mean 6V Mean + 6 V 0.7 0.8 Remote Temperature Error (qC) Local Temperature Error (qC) 0.9 0.5 0.3 0.1 -0.1 -0.3 -0.5 -0.7 -0.9 0.6 0.4 0.2 0 -0.2 -0.4 -0.6 Mean 6V Mean + 6V -0.8 -1.1 -40 -25 -10 5 20 35 50 65 80 Ambient Temperature (qC) 95 -1 -40 110 125 Typical behavior of 25 devices over temperature -10 5 20 35 50 65 80 Ambient Temperature (qC) 95 110 125 Typical behavior of 25 devices over temperature Figure 2. Local Temperature Error vs Ambient Temperature Figure 3. Remote Temperature Error vs Ambient Temperature 20 1 D+ to GND D+ to V+ 0 -20 -40 0.8 Remote Temperature Error (qC) Remote Temperature Error (qC) -25 0.6 0.4 0.2 0 -0.2 -0.4 -0.6 -0.8 -60 -1 1 2 3 4 5 6 7 8 10 20 30 40 50 70 100 Leakage Resistance (M:) 0 500 1000 1500 2000 Series Resistance (:) 2500 3000 D004 No physical capacitance during measurement Figure 4. Remote Temperature Error vs Leakage Resistance Figure 5. Remote Temperature Error vs Series Resistance 400 350 -5 Quiescent Current (PA) Remote Temperature Error (qC) 0 -10 -15 -20 -25 300 250 200 150 100 50 -30 0 5 10 15 Differential Capacitance (nF) 20 25 0 0.01 D005 0.1 1 Conversion Rate (Hz) 10 100 D007 No physical series resistance on D+, D– pins during measurement Figure 6. Remote Temperature Error vs Differential Capacitance Figure 7. Quiescent Current vs Conversion Rate Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 7 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com Typical Characteristics (continued) At TA = 25°C and V+ = 3.6 V, unless otherwise noted. 180 175 200 Quiescent Current (PA) Shutdown Quiescent Current (PA) 250 150 100 50 0 1k 170 165 160 155 10k 100k Clock Frequency (Hz) 1M 10M 150 1.5 2 2.5 3 Supply Voltage (V) D008 3.5 4 D009 16 samples per second (default mode) Figure 8. Shutdown Quiescent Current vs SCL Clock Frequency Figure 9. Quiescent Current vs Supply Voltage (At Default Conversion Rate of 16 Conversions per Second) Shutdown Quiescent Current (PA) 3 2.5 2 1.5 1 0.5 1.5 2 2.5 3 Supply Voltage (V) 3.5 4 D010 Figure 10. Shutdown Quiescent Current vs Supply Voltage 8 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 8 Detailed Description 8.1 Overview The TMP461 device is a digital temperature sensor that combines a local temperature measurement channel and a remote-junction temperature measurement channel in a single WQFN-10 package. The device is two-wireand SMBus-interface-compatible with nine pin-programmable bus address options, and is specified over a temperature range of –40°C to 125°C. The TMP461 device also contains multiple registers for programming and holding configuration settings, temperature limits, and temperature measurement results. 8.2 Functional Block Diagram V+ TMP461 A0 Register Bank Oscillator A1 SCL Serial Interface Control Logic SDA 16 x I 6xI D+ I ALERT/THERM2 ADC DTHERM Internal BJT GND Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 9 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.3 Feature Description 8.3.1 Temperature Measurement Data The local and remote temperature sensors have a resolution of 12 bits (0.0625°C). Temperature data that result from conversions within the default measurement range are represented in binary form, as shown in the Standard Binary column of Table 1. Any temperatures above 127°C result in a value that rails to 127.9375 (7FFh). The device can be set to measure over an extended temperature range by changing bit 2 (RANGE) of the configuration register from low to high. The change in measurement range and data format from standard binary to extended binary occurs at the next temperature conversion. For data captured in the extended temperature range configuration, an offset of 64 (40h) is added to the standard binary value, as shown in the Extended Binary column of Table 1. This configuration allows measurement of temperatures as low as –64°C, and as high as 191°C; however, most temperature-sensing diodes only operate within the range of –55°C to 150°C. Additionally, the TMP461 is specified only for ambient temperatures ranging from –40°C to 125°C; parameters in the Absolute Maximum Ratings table must be observed. Table 1. Temperature Data Format (Local and Remote Temperature High Bytes) LOCAL AND REMOTE TEMPERATURE REGISTER HIGH BYTE VALUE (1°C Resolution) STANDARD BINARY (1) EXTENDED BINARY (2) TEMPERATURE (°C) BINARY HEX BINARY –64 1100 0000 C0 0000 0000 00 –50 1100 1110 CE 0000 1110 0E –25 1110 0111 E7 0010 0111 27 0 0000 0000 00 0100 0000 40 1 0000 0001 01 0100 0001 41 5 0000 0101 05 0100 0101 45 10 0000 1010 0A 0100 1010 4A 25 0001 1001 19 0101 1001 59 50 0011 0010 32 0111 0010 72 75 0100 1011 4B 1000 1011 8B 100 0110 0100 64 1010 0100 A4 125 0111 1101 7D 1011 1101 BD 127 0111 1111 7F 1011 1111 BF 150 0111 1111 7F 1101 0110 D6 175 0111 1111 7F 1110 1111 EF 191 0111 1111 7F 1111 1111 FF (1) (2) 10 HEX Resolution is 1°C per count. Negative numbers are represented in twos complement format. Resolution is 1°C per count. All values are unsigned with a –64°C offset. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 Both local and remote temperature data use two bytes for data storage. The high byte stores the temperature with 1°C resolution. The second or low byte stores the decimal fraction value of the temperature and allows a higher measurement resolution, as shown in Table 2. The measurement resolution for both the local and the remote channels is 0.0625°C. Table 2. Decimal Fraction Temperature Data Format (Local and Remote Temperature Low Bytes) (1) TEMPERATURE REGISTER LOW BYTE VALUE (0.0625°C Resolution) (1) TEMPERATURE (°C) STANDARD AND EXTENDED BINARY HEX 0 0000 0000 00 0.0625 0001 0000 10 0.1250 0010 0000 20 0.1875 0011 0000 30 0.2500 0100 0000 40 0.3125 0101 0000 50 0.3750 0110 0000 60 0.4375 0111 0000 70 0.5000 1000 0000 80 0.5625 1001 0000 90 0.6250 1010 0000 A0 0.6875 1011 0000 B0 0.7500 1100 0000 C0 0.8125 1101 0000 D0 0.8750 1110 0000 E0 0.9375 1111 0000 F0 Resolution is 0.0625°C per count. All possible values are shown. 8.3.1.1 Standard Binary to Decimal Temperature Data Calculation Example High-byte conversion (for example, 0111 0011): Convert the right-justified binary high byte to hexadecimal. From hexadecimal, multiply the first number by 160 = 1 and the second number by 161 = 16. The sum equals the decimal equivalent. 0111 0011b → 73h → (3 × 160) + (7 × 161) = 115. Low-byte conversion (for example, 0111 0000): To convert the left-justified binary low-byte to decimal, use bits 7 through 4 and ignore bits 3 through 0 because they do not affect the value of the number. 0111b → (0 × 1 / 2)1 + (1 × 1 / 2)2 + (1 × 1 / 2)3 + (1 × 1 / 2)4 = 0.4375. 8.3.1.2 Standard Decimal to Binary Temperature Data Calculation Example For positive temperatures (for example, 20°C): (20°C) / (1°C per count) = 20 → 14h → 0001 0100. Convert the number to binary code with 8-bit, right-justified format, and MSB = 0 to denote a positive sign. 20°C is stored as 0001 0100 → 14h. For negative temperatures (for example, –20°C): (|–20|) / (1°C per count) = 20 → 14h → 0001 0100. Generate the twos complement of a negative number by complementing the absolute value binary number and adding 1. –20°C is stored as 1110 1100 → ECh. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 11 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.3.2 Series Resistance Cancellation Series resistance cancellation automatically eliminates the temperature error caused by the resistance of the routing to the remote transistor or by the resistors of the optional external low-pass filter. A total of up to 1 kΩ of series resistance can be cancelled by the TMP461 device, thus eliminating the need for additional characterization and temperature offset correction. See Figure 5 (Remote Temperature Error vs Series Resistance) for details on the effects of series resistance on sensed remote temperature error. 8.3.3 Differential Input Capacitance The TMP461 device tolerates differential input capacitance of up to 1000 pF with minimal change in temperature error. The effect of capacitance on the sensed remote temperature error is illustrated in Figure 6 (Remote Temperature Error vs Differential Capacitance). 8.3.4 Filtering Remote junction temperature sensors are usually implemented in a noisy environment. Noise is most often created by fast digital signals that can corrupt measurements. The TMP461 device has a built-in, 65-kHz filter on the D+ and D– inputs to minimize the effects of noise. However, a bypass capacitor placed differentially across the inputs of the remote temperature sensor is recommended to make the application more robust against unwanted coupled signals. For this capacitor, select a value between 100 pF differential and 1 nF. Some applications attain better overall accuracy with additional series resistance. However, this increased accuracy is application-specific. When series resistance is added, the total value must not be greater than 1 kΩ. If filtering is required, suggested component values are 100 pF differential and 50 Ω on each input; exact values are application-specific. 100 100 90 90 80 80 70 Temperature (°C) Temperature (°C) Additionally, a digital filter is available for the remote temperature measurements to further reduce the effect of noise. This filter is programmable and has two levels when enabled. Level 1 performs a moving average of four consecutive samples. Level 1 filtering can be achieved by setting the digital filter control register (read address 24h, write address 24h) to 01h. Level 2 performs a moving average of eight consecutive samples. Level 2 filtering can be achieved by setting the digital filter control register (read address 24h, write address 24h) to 02h. The value stored in the remote temperature result register is the output of the digital filter, and is the value that the ALERT and THERM limits are compared to. The digital filter provides additional immunity to noise and spikes on the ALERT and THERM outputs. The filter responses to impulse and step inputs are shown in Figure 11 and Figure 12, respectively. The filter can be enabled or disabled by programming the desired levels in the digital filter register; see Table 4. The digital filter is disabled by default and on POR. Disabled 60 50 40 Level1 Level 2 30 70 Disabled 60 Level 1 Level 2 50 40 30 20 20 10 10 0 0 0 1 2 3 4 5 6 7 8 9 Samples 10 11 12 13 14 15 0 1 Figure 11. Filter Response to Impulse Inputs 12 Submit Documentation Feedback 2 3 4 5 6 7 8 9 Samples 10 11 12 13 14 15 Figure 12. Filter Response to Step Inputs Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 8.3.5 Sensor Fault The TMP461 device can sense a fault at the D+ input resulting from an incorrect diode connection. The TMP461 device can also sense an open circuit. Short-circuit conditions return a value of –64°C. The detection circuitry consists of a voltage comparator that trips when the voltage at D+ exceeds (V+) – 0.3 V (typical). The comparator output is continuously checked during a conversion. If a fault is detected, then OPEN (bit 2) in the status register is set to 1. When not using the remote sensor with the TMP461 device, the D+ and D– inputs must be connected together to prevent meaningless fault warnings. 8.3.6 ALERT and THERM Functions Operation of the ALERT (pin 7) and THERM (pin 4) interrupts is shown in Figure 13. Operation of the THERM (pin 4) and THERM2 (pin 7) interrupts is shown in Figure 14. The ALERT and THERM pin setting is determined by bit 5 of the configuration register. The hysteresis value is stored in the THERM hysteresis register and applies to both the THERM and THERM2 interrupts. The value of the CONAL[2:0] bits in the consecutive ALERT register (see Table 4) determines the number of limit violations before the ALERT pin is tripped. The default value is 000b and corresponds to one violation, 001b programs two consecutive violations, 011b programs three consecutive violations, and 111b programs four consecutive violations. The CONAL[2:0] bits provide additional filtering for the ALERT pin state. Temperature Conversion Complete Temperature Conversion Complete 150 150 140 140 130 130 Temperature (°C) 110 THERM Limit 100 THERM Limit - Hysteresis 90 High Temperature Limit Temperature (°C) 120 120 110 THERM Limit 100 THERM Limit - Hysteresis 90 THERM2 Limit 80 80 70 70 THERM2 Limit - Hysteresis Measured Temperature 60 Measured Temperature 60 50 50 Time Time ALERT output serviced by master THERM2 ALERT THERM THERM Figure 13. ALERT and THERM Interrupt Operation Figure 14. THERM and THERM2 Interrupt Operation 8.4 Device Functional Modes 8.4.1 Shutdown Mode (SD) The TMP461 shutdown mode enables the user to save maximum power by shutting down all device circuitry other than the serial interface, and reducing current consumption to typically less than 3 μA; see Figure 10 (Shutdown Quiescent Current vs Supply Voltage). Shutdown mode is enabled when the SD bit (bit 6) of the configuration register is high; the device shuts down after the current conversion is finished. When the SD bit is low, the device maintains a continuous-conversion state. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 13 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.5 Programming 8.5.1 Serial Interface The TMP461 device operates only as a slave device on either the two-wire bus or the SMBus. Connections to either bus are made using the open-drain I/O lines, SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP461 device supports the transmission protocol for fast (1 kHz to 400 kHz) and high-speed (1 kHz to 2.17 MHz) modes. All data bytes are transmitted MSB first. 8.5.1.1 Bus Overview The TMP461 device is SMBus-interface-compatible. In SMBus protocol, the device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the start and stop conditions. To address a specific device, a start condition is initiated. A start condition is indicated by pulling the data line (SDA) from a high-to-low logic level when SCL is high. All slaves on the bus shift in the slave address byte, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an acknowledge bit and pulling SDA low. Data transfer is then initiated and sent over eight clock pulses followed by an acknowledge bit. During data transfer, SDA must remain stable when SCL is high. A change in SDA when SCL is high is interpreted as a control signal. After all data are transferred, the master generates a stop condition. A stop condition is indicated by pulling SDA from low to high when SCL is high. 8.5.1.2 Bus Definitions The TMP461 device is two-wire- and SMBus-compatible. Figure 15 and Figure 16 illustrate the timing for various operations on the TMP461 device. The bus definitions are as follows: Bus Idle: Both SDA and SCL lines remain high. Start Data Transfer: A change in the state of the SDA line (from high to low) when the SCL line is high defines a start condition. Each data transfer initiates with a start condition. Stop Data Transfer: A change in the state of the SDA line (from low to high) when the SCL line is high defines a stop condition. Each data transfer terminates with a repeated start or stop condition. Data Transfer: The number of data bytes transferred between a start and stop condition is not limited and is determined by the master device. The receiver acknowledges the data transfer. Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable low during the high period of the acknowledge clock pulse. Take setup and hold times into account. On a master receive, data transfer termination can be signaled by the master generating a not-acknowledge on the last byte that is transmitted by the slave. 14 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 Programming (continued) 1 9 9 1 SCL ¼ SDA 0 1 0 1 1 0(1) 0 R/W Start By Master P7 P6 P5 P4 P3 P2 P1 P0 ACK By Device ¼ ACK By Device Frame 2 Pointer Register Byte Frame 1 Two-Wire Slave Address Byte 9 1 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 D1 D0 ACK By Device Stop By Master Frame 3 Data Byte 1 (1) Slave address 1001100 is shown. Figure 15. Two-Wire Timing Diagram for Write Word Format 1 9 1 9 SCL ¼ SDA 1 0 0 1 1 0 0(1) P7 R/W Start By Master P6 P5 P4 P3 P2 P1 P0 ACK By Device ACK By Device Frame 1 Two-Wire Slave Address Byte 1 ¼ Frame 2 Pointer Register Byte 9 1 9 SCL (Continued) ¼ SDA (Continued) 1 0 0 1 1 0 0(1) R/W Start By Master D7 D6 ACK By Device Frame 3 Two-Wire Slave Address Byte (1) Slave address 1001100 is shown. (2) The master must leave SDA high to terminate a single-byte read operation. D5 D4 D3 D2 D1 D0 From Device ¼ NACK By Master(2) Frame 4 Data Byte 1 Read Register Figure 16. Two-Wire Timing Diagram for Single-Byte Read Format 8.5.1.3 Serial Bus Address To communicate with the TMP461 device, the master must first address slave devices using a slave address byte. The slave address byte consists of seven address bits and a direction bit indicating the intent of executing a read or write operation. The TMP461 allows up to nine devices to be connected to the SMBus, depending on the A0, A1 pin connections as described in Table 3. The A0 and A1 address pins must be isolated from noisy or high-frequency signals traces in order to avoid false address settings when these pins are set to a float state. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 15 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com Programming (continued) Table 3. TMP461 Slave Address Options SLAVE ADDRESS A1 CONNECTION A0 CONNECTION BINARY HEX GND GND 1001 000 48 GND Float 1001 001 49 GND V+ 1001 010 4A Float GND 1001 011 4B Float Float 1001 100 4C Float V+ 1001 101 4D V+ GND 1001 110 4E V+ Float 1001 111 4F V+ V+ 1010 000 50 8.5.1.4 Read and Write Operations Accessing a particular register on the TMP461 device is accomplished by writing the appropriate value to the pointer register. The value for the pointer register is the first byte transferred after the slave address byte with the R/W bit low. Every write operation to the TMP461 device requires a value for the pointer register (see Figure 15). When reading from the TMP461 device, the last value stored in the pointer register by a write operation is used to determine which register is read by a read operation. To change which register is read for a read operation, a new value must be written to the pointer register. This transaction is accomplished by issuing a slave address byte with the R/W bit low, followed by the pointer register byte; no additional data are required. The master can then generate a start condition and send the slave address byte with the R/W bit high to initiate the read command; see Figure 16 for details of this sequence. If repeated reads from the same register are desired, continually sending the pointer register bytes is not necessary because the TMP461 retains the pointer register value until it is changed by the next write operation. The register bytes are sent MSB first, followed by the LSB. Terminate read operations by issuing a not-acknowledge command at the end of the last byte to be read. For a single-byte operation, the master must leave the SDA line high during the acknowledge time of the first byte that is read from the slave. 8.5.1.5 Timeout Function The TMP461 device resets the serial interface if either SCL or SDA are held low for 25 ms (typical) between a start and stop condition. If the TMP461 device is holding the bus low, the device releases the bus and waits for a start condition. To avoid activating the timeout function, maintaining a communication speed of at least 1 kHz for the SCL operating frequency is necessary. 8.5.1.6 High-Speed Mode For the two-wire bus to operate at frequencies above 1 MHz, the master device must issue a high-speed mode (HS-mode) master code (0000 1xxx) as the first byte after a start condition to switch the bus to high-speed operation. The TMP461 device does not acknowledge this byte, but switches the input filters on SDA and SCL and the output filter on SDA to operate in HS-mode, thus allowing transfers at up to 2.17 MHz. After the HSmode master code is issued, the master transmits a two-wire slave address to initiate a data transfer operation. The bus continues to operate in HS-mode until a stop condition occurs on the bus. Upon receiving the stop condition, the TMP461 device switches the input and output filters back to fast mode operation. 8.5.2 General-Call Reset The TMP461 device supports reset using the two-wire general-call address 00h (0000 0000b). The TMP461 device acknowledges the general-call address and responds to the second byte. If the second byte is 06h (0000 0110b), the TMP461 device executes a software reset. This software reset restores the power-on reset state to all TMP461 registers and aborts any conversion in progress. The TMP461 device takes no action in response to other values in the second byte. 16 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 8.6 Register Map Table 4. Register Map BIT DESCRIPTION POINTER READ (HEX) POINTER WRITE (HEX) POR (HEX) 7 6 5 4 3 2 1 0 00 N/A 00 LT11 LT10 LT9 LT8 LT7 LT6 LT5 LT4 Local Temperature Register (high byte) 01 N/A 00 RT11 RT10 RT9 RT8 RT7 RT6 RT5 RT4 Remote Temperature Register (high byte) 02 N/A N/A BUSY LHIGH LLOW RHIGH RLOW OPEN RTHRM LTHRM 03 09 00 MASK1 SD ALERT/THERM2 0 0 RANGE 0 0 04 0A 08 0 0 0 0 CR3 CR2 CR1 CR0 05 0B 7F LTHL11 LTHL10 LTHL9 LTHL8 LTHL7 LTHL6 LTHL5 LTHL4 Local Temperature High Limit Register 06 0C 80 LTLL11 LTLL10 LTLL9 LTLL8 LTLL7 LTLL6 LTLL5 LTLL4 Local Temperature Low Limit Register 07 0D 7F RTHL11 RTHL10 RTHL9 RTHL8 RTHL7 RTHL6 RTHL5 RTHL4 Remote Temperature High Limit Register (high byte) 08 0E 80 RTLL11 RTLL10 RTLL9 RTLL8 RTLL7 RTLL6 RTLL5 RTLL4 Remote Temperature Low Limit Register (high byte) N/A 0F N/A X X X X X X X X One-Shot Start Register (1) 10 N/A 00 RT3 RT2 RT1 RT0 0 0 0 0 Remote Temperature Register (low byte) 11 11 00 RTOS11 RTOS10 RTOS9 RTOS8 RTOS7 RTOS6 RTOS5 RTOS4 Remote Temperature Offset Register (high byte) 12 12 00 RTOS3 RTOS2 RTOS1 RTOS0 0 0 0 0 Remote Temperature Offset Register (low byte) 13 13 F0 RTHL3 RTHL2 RTHL1 RTHL0 0 0 0 0 Remote Temperature High Limit Register (low byte) 14 14 00 RTLL3 RTLL2 RTLL1 RTLL0 0 0 0 0 Remote Temperature Low Limit Register (low byte) 15 N/A 00 LT3 LT2 LT1 LT0 0 0 0 0 Local Temperature Register (low byte) 16 16 03 0 0 0 0 0 0 REN LEN 19 19 7F RTH11 RTH10 RTH9 RTH8 RTH7 RTH6 RTH5 RTH4 Remote Temperature THERM Limit Register 20 20 7F LTH11 LTH10 LTH9 LTH8 LTH7 LTH6 LTH5 LTH4 Local Temperature THERM Limit Register 21 21 0A HYS11 HYS10 HYS9 HYS8 HYS7 HYS6 HYS5 HYS4 THERM Hysteresis Register 22 22 01 0 0 0 0 CONAL2 CONAL1 CONAL0 1 Consecutive ALERT Register 23 23 00 NC7 NC6 NC5 NC4 NC3 NC2 NC1 NC0 η-Factor Correction Register 24 24 00 0 0 0 0 0 0 DF1 DF0 Digital Filter Control Register FE N/A 55 0 1 0 1 0 1 0 1 (1) REGISTER DESCRIPTION Status Register Configuration Register Conversion Rate Register Channel Enable Register Manufacturer Identification Register X = undefined. Writing any value to this register initiates a one-shot start; see the One-Shot Conversion section. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 17 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.6.1 Register Information The TMP461 device contains multiple registers for holding configuration information, temperature measurement results, and status information. These registers are described in Figure 17 and Table 4. 8.6.1.1 Pointer Register Figure 17 shows the internal register structure of the TMP461 device. The 8-bit pointer register is used to address a given data register. The pointer register identifies which of the data registers must respond to a read or write command on the two-wire bus. This register is set with every write command. A write command must be issued to set the proper value in the pointer register before executing a read command. Table 4 describes the pointer register and the internal structure of the TMP461 registers. The power-on reset (POR) value of the pointer register is 00h (0000 0000b). Pointer Register Local and Remote Temperature Registers Status Register Configuration Register SDA Conversion Rate Register Local and Remote Temperature Limit Registers One-Shot Start Register Remote Temperature Offset Registers I/O Control Interface Local and Remote THERM Limit Registers THERM Hysteresis Register Consecutive ALERT Register N-factor Correction Register SCL Digital Filter Register Manufacturer ID Register Figure 17. Internal Register Structure 8.6.1.2 Local and Remote Temperature Registers The TMP461 device has multiple 8-bit registers that hold temperature measurement results. The eight most significant bits (MSBs) of the local temperature sensor result are stored in register 00h, and the four least significant bits (LSBs) are stored in register 15h (the four MSBs of register 15h). The eight MSBs of the remote temperature sensor result are stored in register 01h, and the four LSBs are stored in register 10h (the four MSBs of register 10h). The four LSBs of both the local and remote sensor indicate the temperature value after the decimal point (for example, if the temperature result is 10.0625°C, then the high byte is 0000 1010 and the low byte is 0001 0000). These registers are read-only and are updated by the ADC each time a temperature measurement is completed. When the full temperature value is needed, reading the MSB value first causes the LSB value to be locked (the ADC does not write to it) until the LSB value is read. The same thing happens upon reading the LSB value first (the MSB value is locked until it is read). This mechanism assures that both bytes of the read operation are from the same ADC conversion. This assurance remains valid only until another register is read. For proper operation, read the high byte of the temperature result first. Read the low byte register in the next read command; if the LSBs are not needed, the register can be left unread. The power-on reset value of all temperature registers is 00h. 18 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 8.6.1.3 Status Register The status register reports the state of the temperature ADC, the temperature limit comparators, and the connection to the remote sensor. Table 5 lists the status register bits. The status register is read-only and is read by accessing pointer address 02h. Table 5. Status Register Format STATUS REGISTER (Read = 02h, Write = N/A) BIT NUMBER (1) BIT NAME FUNCTION 7 BUSY 6 LHIGH (1) = 1 when the ADC is converting = 1 when the local high temperature limit is tripped 5 LLOW (1) = 1 when the local low temperature limit is tripped 4 RHIGH (1) 3 RLOW (1) = 1 when the remote low temperature limit is tripped 2 OPEN (1) = 1 when the remote sensor is an open circuit 1 RTHRM = 1 when the remote THERM limit is tripped 0 LTHRM = 1 when the local THERM limit is tripped = 1 when the remote high temperature limit is tripped These flags stay high until the status register is read or are reset by a POR when pin 7 is configured as ALERT. Only bit 2 (OPEN) stays high until the status register is read or is reset by a POR when pin 7 is configured as THERM2. The BUSY bit = 1 if the ADC is making a conversion. This bit is set to 0 if the ADC is not converting. The LHIGH and LLOW bits indicate a local sensor overtemperature or undertemperature event, respectively. The RHIGH and RLOW bits indicate a remote sensor overtemperature or undertemperature event, respectively. The HIGH bit is set when the temperature exceeds the high limit in alert mode and therm mode and the low bit is set when the temperature goes below the low limit in alert mode. The OPEN bit indicates an open-circuit condition on the remote sensor. When pin 7 is configured as the ALERT output, the five flags are NORed together. If any of the five flags are high, the ALERT interrupt latch is set and the ALERT output goes low. Reading the status register clears the five flags, provided that the condition that caused the setting of the flags is not present anymore (that is, the value of the corresponding result register is within the limits, or the remote sensor is connected properly and functional). The ALERT interrupt latch (and the ALERT pin correspondingly) is not reset by reading the status register. The reset is done by the master reading the temperature sensor device address to service the interrupt, and only if the flags are reset and the condition that caused them to be set is no longer present. The RTHRM and LTHRM flags are set when the corresponding temperature exceeds the programmed THERM limit. These flags are reset automatically when the temperature returns to within the limits. The THERM output goes low in the case of overtemperature on either the local or remote channel, and goes high as soon as the measurements are within the limits again. The THERM hysteresis register (21h) allows hysteresis to be added so that the flag resets and the output goes high when the temperature returns to or goes below the limit value minus the hysteresis value. When pin 7 is configured as THERM2, only the high limits matter. The LHIGH and RHIGH flags are set if the respective temperatures exceed the limit values, and the pin goes low to indicate the event. The LLOW and RLOW flags have no effect on THERM2 and the output behaves the same way when configured as THERM. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 19 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.6.1.4 Configuration Register The configuration register sets the temperature range, the ALERT/THERM modes, and controls the shutdown mode. The configuration register is set by writing to pointer address 09h, and is read by reading from pointer address 03h. Table 6 summarizes the bits of the configuration register. Table 6. Configuration Register Bit Descriptions CONFIGURATION REGISTER (Read = 03h, Write = 09h, POR = 00h) BIT NUMBER NAME 7 MASK1 6 SD 5 ALERT/THERM2 4:3 Reserved 2 RANGE 1:0 Reserved FUNCTION POWER-ON RESET VALUE 0 = ALERT enabled 1 = ALERT masked 0 0 = Run 1 = Shut down 0 0 = ALERT 1 = THERM2 0 — 0 0 = –40°C to +127°C 1 = –64°C to +191°C 0 — 0 MASK1 (bit 7) of the configuration register masks the ALERT output. If MASK1 is 0 (default), the ALERT output is enabled. If MASK1 is set to 1, the ALERT output is disabled. This configuration applies only if the value of ALERT/THERM2 (bit 5) is 0 (that is, pin 7 is configured as the ALERT output). If pin 7 is configured as the THERM2 output, the value of the MASK1 bit has no effect. The shutdown bit (SD, bit 6) enables or disables the temperature-measurement circuitry. If SD = 0 (default), the TMP461 device converts continuously at the rate set in the conversion rate register. When SD is set to 1, the TMP461 device stops converting when the current conversion sequence is complete and enters a shutdown mode. When SD is set to 0 again, the TMP461 resumes continuous conversions. When SD = 1, a single conversion can be started by writing to the one-shot start register; see the One-Shot Start Register section for more information. ALERT/THERM2 (bit 5) sets the configuration of pin 7. If the ALERT/THERM2 bit is 0 (default), then pin 7 is configured as the ALERT output; if this bit is set to 1, then pin 7 is configured as the THERM2 output. The temperature range is set by configuring RANGE (bit 2) of the configuration register. Setting this bit low (default) configures the TMP461 device for the standard measurement range (–40°C to +127°C); temperature conversions are stored in the standard binary format. Setting bit 2 high configures the TMP461 device for the extended measurement range (–64°C to +191°C); temperature conversions are stored in the extended binary format (see Table 1). The remaining bits of the configuration register are reserved and must always be set to 0. The power-on reset value for this register is 00h. 20 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 8.6.1.5 Conversion Rate Register The conversion rate register (read address 04h, write address 0Ah) controls the rate at which temperature conversions are performed. This register adjusts the idle time between conversions but not the conversion time itself, thereby allowing the TMP461 power dissipation to be balanced with the temperature register update rate. Table 7 lists the conversion rate options and corresponding time between conversions. The default value of the register is 08h, which gives a default rate of 16 conversions per second. Table 7. Conversion Rate VALUE CONVERSIONS PER SECOND TIME (Seconds) 00h 0.0625 16 01h 0.125 8 02h 0.25 4 03h 0.5 2 04h 1 1 05h 2 0.5 06h 4 0.25 07h 8 0.125 08h 16 (default) 0.0625 (default) 09h 32 0.03125 8.6.1.6 One-Shot Start Register When the TMP461 device is in shutdown mode (SD = 1 in the configuration register), a single conversion is started by writing any value to the one-shot start register, pointer address 0Fh. This write operation starts one conversion and comparison cycle on either both the local and remote sensors or on only one or the other sensor, depending on the LEN and REN values configured in the channel enable register (read address 16h, write address 16h). The TMP461 device returns to shutdown mode when the cycle completes. The value of the data sent in the write command is irrelevant and is not stored by the TMP461 device. 8.6.1.7 Channel Enable Register The channel enable register (read address 16h, write address 16h) enables or disables the temperature conversion of remote and local temperature sensors. LEN (bit 0) of the channel enable register enables/disables the conversion of local temperature. REN (bit 1) of the channel enable register enables/disables the conversion of remote temperature. Both LEN and REN are set to 1 (default), this enables the ADC to convert both local and remote temperatures. If LEN is set to 0, the local temperature conversion is disabled and similarly if REN is set to 0, the remote temperature conversion is disabled. Both local and remote temperatures are converted by the internal ADC as a default mode. Channel Enable register can be configured to achieve power savings by reducing the total ADC conversion time to half for applications that do not require both remote and local temperature information. 8.6.1.8 Consecutive ALERT Register The Consecutive ALERT register (read address 22h, write address 22h) controls the number of out-of-limit temperature measurements required for ALERT to be asserted. Table 8 summarizes the values of the consecutive ALERT register. The number programmed in the consecutive ALERT applies to both the remote and local temperature results. When the number of times that the temperature result consecutively exceeds the high limit register value is equal to the value programmed in the consecutive ALERT register, ALERT is asserted. Similarly, the consecutive ALERT register setting is also applicable to the low-limit register. Table 8. Consecutive ALERT REGISTER VALUE NUMBER OF OUT-OF-LIMIT MEASUREMENTS REQUIRED TO ASSERT ALERT 01h 1 (default) 03h 2 07h 3 0Fh 4 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 21 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 8.6.1.9 η-Factor Correction Register The TMP461 device allows for a different η-factor value to be used for converting remote channel measurements to temperature. The remote channel uses sequential current excitation to extract a differential VBE voltage measurement to determine the temperature of the remote transistor. Equation 1 shows this voltage and temperature. VBE2 - VBE1 = hkT I ln 2 q I1 (1) The value η in Equation 1 is a characteristic of the particular transistor used for the remote channel. The poweron reset value for the TMP461 device is η = 1.008. The value in the η-factor correction register can be used to adjust the effective η-factor according to Equation 2 and Equation 3. eff § 1.008 u 2088 · ¨ ¸ © 2088 NADJUST ¹ NADJUST § 1.008 u 2088 · ¨ ¸ eff © ¹ (2) 2088 (3) The η-factor correction value must be stored in twos complement format, yielding an effective data range from –128 to 127. The η-factor correction value is written to and read from pointer address 23h. The register power-on reset value is 00h, thus having no effect unless a different value is written to it. The resolution of the η-factor register is 0.000483. Table 9. η-Factor Range NADJUST BINARY HEX DECIMAL η 0111 1111 7F 127 0.950205 0000 1010 0A 10 1.003195 0000 1000 08 8 1.004153 0000 0110 06 6 1.005112 0000 0100 04 4 1.006073 0000 0010 02 2 1.007035 0000 0001 01 1 1.007517 0000 0000 00 0 1.008 1111 1111 FF –1 1.008483 1111 1110 FE –2 1.008966 1111 1100 FC –4 1.009935 1111 1010 FA –6 1.010905 1111 1000 F8 –8 1.011877 1111 0110 F6 –10 1.012851 1000 0000 80 –128 1.073829 8.6.1.10 Remote Temperature Offset Register The offset register allows the TMP461 device to store any system offset compensation value that may result from precision calibration. The value in the register is stored in the same format as the temperature result, and is added to the remote temperature result upon every conversion. Combined with the η-factor correction, this function allows for very accurate system calibration over the entire temperature range. 8.6.1.11 Manufacturer Identification Register The TMP461 device allows for the two-wire bus controller to query the device for manufacturer and device IDs to enable software identification of the device at the particular two-wire bus address. The manufacturer ID is obtained by reading from pointer address FEh. The TMP461 device reads 55h for the manufacturer code. 22 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 9 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 9.1 Application Information The TMP461 device requires only a transistor connected between the D+ and D– pins for remote temperature measurement. Tie the D+ pin to GND if the remote channel is not used and only the local temperature is measured. The SDA, ALERT, and THERM pins (and SCL, if driven by an open-drain output) require pullup resistors as part of the communication bus. A 0.1-µF power-supply decoupling capacitor is recommended for local bypassing. Figure 18 and Figure 19 illustrate the typical configurations for the TMP461 device. 9.2 Typical Application 1.7V to 3.6V RS(2) 10k (typ) 0.1µF CDIFF(3) RS(2) 10k (typ) 10k (typ) 10k (typ) 10 A1 Diode-connected configuration(1) 1 9 V+ SCL D+ SDA Series Resistance RS(2) RS(2) 2 8 CDIFF(3) SMBus Controller TMP461 3 ALERT / THERM2 D4 Transistor-connected configuration(1) 7 6 GND THERM A0 5 Over-Temperature Shutdown (1) The diode-connected configuration provides better settling time. The transistor-connected configuration provides better series resistance cancellation. (2) RS (optional) is < 1 kΩ in most applications. RS is the combined series resistance connected externally to the D+, Dpins. RS selection depends on the application; see the Filtering section. (3) CDIFF (optional) is < 1000 pF in most applications. CDIFF selection depends on the application; see the Filtering section and Figure 6 (Remote Temperature Error vs Differential Capacitance). Figure 18. TMP461 Basic Connections Using a Discrete Remote Transistor Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 23 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com Typical Application (continued) 1.7 V to 3.6 V 1.7 V to 3.6 V 10 A1 Processor or ASIC 1 9 SCL V+ 2 Built-In Thermal Transistor, Diode 3 8 D+ TMP461 D- ALERT/THERM2 4 SDA GND THERM 7 SMBus Controller 6 A0 5 Overtemperature Shutdown Figure 19. TMP461 Basic Connections Using a Processor Built-In Remote Transistor 9.2.1 Design Requirements The TMP461 device is designed to be used with either discrete transistors or substrate transistors built into processor chips and application-specific integrated circuits (ASICs). Either NPN or PNP transistors can be used, as long as the base-emitter junction is used as the remote temperature sense. NPN transistors must be diodeconnected. PNP transistors can either be transistor- or diode-connected (see Figure 18). Errors in remote temperature sensor readings are typically the consequence of the ideality factor and current excitation used by the TMP461 device versus the manufacturer-specified operating current for a given transistor. Some manufacturers specify a high-level and low-level current for the temperature-sensing substrate transistors. The TMP461 device uses 7.5 μA for ILOW and 120 μA for IHIGH. The ideality factor (η) is a measured characteristic of a remote temperature sensor diode as compared to an ideal diode. The TMP461 allows for different η-factor values; see the η-Factor Correction Register section. The ideality factor for the TMP461 device is trimmed to be 1.008. For transistors that have an ideality factor that does not match the TMP461, Equation 4 can be used to calculate the temperature error. NOTE For Equation 4 to be used correctly, the actual temperature (°C) must be converted to Kelvin (K). TERR = h - 1.008 ´ (273.15 + T(°C)) 1.008 where • • • TERR = error in the TMP461 device because η ≠ 1.008, η = ideality factor of the remote temperature sensor, T(°C) = actual temperature, and (4) In Equation 4, the degree of delta is the same for °C and K. 24 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 Typical Application (continued) For η = 1.004 and T(°C) = 100°C: § 1.004 1.008 · TERR = ¨ ¸ u 273.15 1.008 © ¹ TERR 1.48qC 100qC (5) If a discrete transistor is used as the remote temperature sensor with the TMP461, the best accuracy can be achieved by selecting the transistor according to the following criteria: 1. Base-emitter voltage is > 0.25 V at 7.5 μA, at the highest-sensed temperature. 2. Base-emitter voltage is < 0.95 V at 120 μA, at the lowest-sensed temperature. 3. Base resistance is < 100 Ω. 4. Tight control of VBE characteristics indicated by small variations in hFE (that is, 50 to 150). Based on this criteria, two recommended small-signal transistors are the 2N3904 (NPN) or 2N3906 (PNP). 9.2.2 Detailed Design Procedure The local temperature sensor inside the TMP461 device monitors the ambient air around the device. The thermal time constant for the TMP461 device is approximately two seconds. This constant implies that if the ambient air changes quickly by 100°C, then the TMP461 device takes approximately 10 seconds (that is, five thermal time constants) to settle to within 1°C of the final value. In most applications, the TMP461 package is in electrical, and therefore thermal, contact with the printed circuit board (PCB), as well as subjected to forced airflow. The accuracy of the measured temperature directly depends on how accurately the PCB and forced airflow temperatures represent the temperature that the TMP461 is measuring. Additionally, the internal power dissipation of the TMP461 can cause the temperature to rise above the ambient or PCB temperature. The internal power dissipated as a result of exciting the remote temperature sensor is negligible because of the small currents used. Equation 6 can be used to calculate the average conversion current for power dissipation and self-heating based on the number of conversions per second and temperature sensor channel enabled. Equation 7 shows an example with local and remote sensor channels enabled and 16 conversions per second; see the Electrical Characteristics table for typical values required for these calculations. For a 3.3-V supply and a conversion rate of 16 conversions per second, the TMP461 device dissipates 0.531 mW (PDIQ = 3.3 V × 161 μA) when both the remote and local channels are enabled. Average Conversion Current Local ADC Conversion Time ˜ Conversions per Second ˜ Local Active IQ Remote ADC Conversion Time ˜ Conversions per Second ˜ Remote Active IQ Standby Mode IQ ˜ ª¬1 Local ADC Conversion Time Remote ADC Conversion Time ˜ Conversions per Second º¼ (6) Average Conversion Current § 16 · 15 ms ¨ ¸ ˜ 240 $ © s ¹ § 16 · 15 ms ˜ ¨ ¸ ˜ 400 $ © s ¹ ª § 16 · º 15 $ ˜ « PV PV ˜ ¨ ¸ » © s ¹¼ ¬ 161 $ (7) The temperature measurement accuracy of the TMP461 device depends on the remote and local temperature sensor being at the same temperature as the system point being monitored. If the temperature sensor is not in good thermal contact with the part of the system being monitored, then there is a delay between the sensor response and the system changing temperature. This delay is usually not a concern for remote temperaturesensing applications that use a substrate transistor (or a small, SOT23 transistor) placed close to the device being monitored. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 25 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com Typical Application (continued) 9.2.3 Application Curve Figure 20 shows the typical step response to submerging a sensor in an oil bath with a temperature of 100°C. 100 Temperature (qC) 85 70 55 40 25 -1 1 3 5 7 9 11 Time (s) 13 15 17 19 Figure 20. Temperature Step Response 10 Power Supply Recommendations The TMP461 device operates with a power-supply range of 1.7 V to 3.6 V. The device is optimized for operation at a 3.3-V supply but can measure temperature accurately in the full supply range. A power-supply bypass capacitor is recommended. Place this capacitor as close as possible to the supply and ground pins of the device. A typical value for this supply bypass capacitor is 0.1 μF. Applications with noisy or high-impedance power supplies may require additional decoupling capacitors to reject power-supply noise. 26 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 11 Layout 11.1 Layout Guidelines Remote temperature sensing on the TMP461 device measures very small voltages using very low currents; therefore, noise at the device inputs must be minimized. Most applications using the TMP461 have high digital content, with several clocks and logic-level transitions that create a noisy environment. Layout must adhere to the following guidelines: 1. Place the TMP461 device as close to the remote junction sensor as possible. 2. Route the D+ and D– traces next to each other and shield them from adjacent signals through the use of ground guard traces, as shown in Figure 21. If a multilayer PCB is used, bury these traces between the ground or V+ planes to shield them from extrinsic noise sources. 5-mil (0.127 mm) PCB traces are recommended. 3. Minimize additional thermocouple junctions caused by copper-to-solder connections. If these junctions are used, make the same number and approximate locations of copper-to-solder connections in both the D+ and D– connections to cancel any thermocouple effects. 4. Use a 0.1-μF local bypass capacitor directly between the V+ and GND of the TMP461 device. For optimum measurement performance, minimize filter capacitance between D+ and D– to 1000 pF or less. This capacitance includes any cable capacitance between the remote temperature sensor and the TMP461 device. 5. If the connection between the remote temperature sensor and the TMP461 device is less than 8-in (20.32 cm) long, use a twisted-wire pair connection. For lengths greater than 8 in, use a twisted, shielded pair with the shield grounded as close to the TMP461 device as possible. Leave the remote sensor connection end of the shield wire open to avoid ground loops and 60-Hz pickup. 6. Thoroughly clean and remove all flux residue in and around the pins of the TMP461 device to avoid temperature offset readings as a result of leakage paths between D+ and GND, or between D+ and V+. V+ D+ Ground or V+ layer on bottom and top, if possible. D- GND NOTE: Use a minimum of 5-mil (0.127 mm) traces with 5-mil spacing. Figure 21. Suggested PCB Layer Cross-Section Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 27 TMP461 SBOS722B – JUNE 2015 – REVISED AUGUST 2016 www.ti.com 11.2 Layout Example VIA to Power or Ground Plane VIA to Internal Layer Pullup Resistors Ground Plane Supply Voltage Supply Bypass Capacitor RS 1 V+ 2 3 10 A1 SCL 9 D+ SDA 8 D- ALERT / THERM2 7 CDIFF RS A0 4 THERM 5 Thermal Shutdown GND 6 Serial Bus Traces Figure 22. TMP461 Layout Example 28 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 12 Device and Documentation Support 12.1 Receiving Notification of Documentation Updates To receive notification of documentation updates, navigate to the device product folder on ti.com. In the upper right corner, click on Alert me to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document. 12.2 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 12.3 Trademarks E2E is a trademark of Texas Instruments. SMBus is a trademark of Intel Corporation. All other trademarks are the property of their respective owners. 12.4 Electrostatic Discharge Caution This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. 12.5 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 13 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated Product Folder Links: TMP461 29 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) TMP461AIRUNR-S ACTIVE QFN RUN 10 3000 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 ZDW1 TMP461AIRUNT-S ACTIVE QFN RUN 10 250 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 125 ZDW1 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TMP461AIRUNT-S 价格&库存

很抱歉,暂时无法提供与“TMP461AIRUNT-S”相匹配的价格&库存,您可以联系我们找货

免费人工找货
TMP461AIRUNT-S
  •  国内价格
  • 1+14.04000
  • 10+12.13920
  • 30+10.95120

库存:0