OBSOLETE PRODUCT
Contact Factory for Replacement Model
Product Data Sheet
1 0 ATT NREGULATED 1.0 WATT UNREGULATED SIP DC/DC CONVERTER
HPR10XX
DESCRIPTION
The HPR10XX Series uses advanced circuit design and packaging technology to deliver superior reliability and performance. A 170kHz push-pull oscillator is used in the input stage. Beatfrequency oscillation problems are reduced when using the HPR10XX Series with high frequency isolation amplifiers. Reduced parts count and high efficiency add to the reliability of the HPR10XX Series. The high efficiency of the HPR10XX Series means less internal power dissipation, as low as 190mW. With reduced heat dissipation the HPR10XX Series can operate at higher temperatures with no degradation. In addition, the high efficiency of the HPR10XX Series means the series is able to offer greater than 13 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although a 1mA minimum load is needed to realize published specifications. The HPR10XX Series provides the user low cost without sacrificing reliability. The use of surface mounted devices and advanced manufacturing technologies make it possible to offer premium performance and low cost.
FEATURES
l l l l l l l
LOW COST SINGLE-IN-LINE PACKAGE (SIP) INTERNAL INPUT AND OUTPUT FILTERING NON-CONDUCTIVE CASE HIGH OUTPUT POWER DENSITY: 13 WATTS/INCH3 EXTENDED TEMPERATURE RANGE: -25°C TO +65°C HIGH EFFICIENCY: TO 72% TYPICAL
MECHANICAL
FRONT VIEW
HPR10XX
Notes: All dimensions are in inches (millimeters).
RIGHT SIDE VIEW
GRID: 0.100 inches (2.54 millimeters) PIN PLACEMENT TOLERANCE: ± 0.015"
PIN CONNECTIONS
BOTTOM VIEW
1. +VIN
2. -VIN
4. -VOUT 5. COM* 6. +VOUT
* Common pin not present on
single output models.
Internet: http://www.cd4power.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 520.295.4100 Fax: 520.770.9369
HPR10XX REV D 8/2007
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141
Page 1
ELECTRICAL SPECIFICATIONS
NOMINAL INPUT VOLTAGE MODEL HPR1000 HPR1001 HPR1002 HPR1003 HPR1004 HPR1005 HPR1006 HPR1007 HPR1008 HPR1009 HPR1010 HPR1011 HPR1012 HPR1013 HPR1014 HPR1015 HPR1016 HPR1017 HPR1018 HPR1019 HPR1020 HPR1021 HPR1022 HPR1023 (VDC) 5 5 5 5 5 5 12 12 12 12 12 12 15 15 15 RATED OUTPUT VOLTAGE (VDC) 5 12 15 ±5 ±12 ±15 5 12 15 ±5 ±12 ±15 5 12 15
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. RATED OUTPUT CURRENT (mA) 200 83 67 ±100 ±42 ±34 200 83 67 ±100 ±42 ±34 200 83 67 INPUT CURRENT NO LOAD (mA) 33 33 33 33 33 33 18 18 18 18 18 18 15 15 15 RATED LOAD (mA) 290 290 285 285 285 285 110 107 107 107 107 107 96 94 94 REFLECTED RIPPLE CURRENT (mAp-p) 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 EFFICIENCY (%) 68 69 70 70 70 70 70 71 71 71 71 71 70 70 71
15 15 24 24 24 24 24 24
±12 ±15 5 12 15 ±5 ±12 ±15
±42 ±34 200 83 67 ±100 ±42 ±34
15 15 12 12 12 12 12 12
94 94 60 60 58 58 58 58
10 10 15 15 15 15 15 15
71 71 71 71 72 72 72 72
Note: Other input to output voltages may be available. Please contact factory.
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. PARAMETER INPUT Voltage Range CONDITIONS MIN TYP MAX UNITS
COMMON SPECIFICATIONS
Voltage Rise Time ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Ripple & Noise Voltage
4.5 5 5.5 VDC 10.8 12 13.2 VDC 13.5 15 16.5 VDC 21.6 24 26.4 VDC See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters" 1000 1000 10 25 2 1.0 Rated Load, Nominal VIN BW = DC to 10MHz BW =10Hz to 2MHz 1mA Load, VOUT = 5V 1mA Load, VOUT = 12V 1mA Load, VOUT = 15V ±5 100 30 7 15 18 .01 1 10 3 170 24 2 3.8 1.4 685 211 2 100 8.5 VDC Vpk GΩ pF μArms W % mVp-p mVrms VDC VDC VDC %/Deg C %/%Vin % % kHz % g MHr MHr kHr kHr
60 Hz, 10 Seconds
VISO= 240VAC, 60Hz
Temperature Coefficent REGULATION Line Regulation Load Regulation (5V out only) Load Regulation (All other Models) GENERAL Switching Frequency Frequency Change Package Weight MTTF per MIL-HDBK-217, Rev. E Ground Benign Fixed Ground Naval Sheltered Airborne Uninhabited Fighter Moisture Sensitivity Level (MSL) TEMPERATURE Specification Storage
High Line to Low Line Rated Load to 1mA Load Rated Load to 1mA Load
Over Line and Load Circuit Stress Method TA = +25°C TA = +35°C TA = +35°C TA = +35°C IPC/JEDEC J-STD-20
-25 -50
+25
+65 +110
°C °C
HPR10XX REV D 8/2007
* For demonstrated MTTF results reference Reliability Report HPR105
Page 2
TYPICAL PERFORMANCE CURVES
VOUT VS LOAD (5Vout Models) 5.7 5.5
Vout Vout
VOUT VS LOAD (±5Vout Models) 5.4 5.2
Vout
VOUT VS LOAD (12Vout Models) 12.5 12.4 12.3 12.2 12.1
5.3 5.1 4.9 0 40 80 120 160 Output Current (mA) VOUT VS LOAD (±12Vout Models) 12.6 12.5 12.4
5.0 4.8
12.0 4.6 0 20 40 60 80 Output Current each load (mA) VOUT VS LOAD (15Vout Models) 15.9 15.7
Vout Vout
11.9 0 20 40 60 80 Output Current each load (mA) VOUT VS LOAD (±15Vout Models) 16.5 16.0 15.5
Vout
12.3 12.2 12.1 12.0 0 10 20 30 40 Output Current each load (mA)
15.5 15.3 15.1 14.9 0 20 40 60 80 Output Current each load (mA) OSCILLATION FREQUENCY VS TEMPERATURE 220
15.0 14.5 14.0 13.5 0 0.2 0.4 0.6 0.8 1.0 Output Power each load (Watts)
EFFICIENCY VS LOAD 90 75
Efficiency (%) Efficiency (%)
60 45 30 15 0 0 20 40 60 80 100 % of Rated Load (%)
200 180 160 140 -30 0 30 Temperature (°C) 60 90
SAFE OPERATING AREA
600
LOAD CAPACITANCE vs INPUT RISE TIME (5 Vout models)
60
LOAD CAPACITANCE vs INPUT RISE TIME (15 Vout models)
500
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
400
40
300
30
SAFE OPERATING AREA
200
SAFE OPERATING AREA
20
100
10
0 0 5 10 15 20 25 30 35 Rise Time of Input Voltage (mS) 40 45 50
0 0 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS)
LOAD CAPACITANCE vs INPUT RISE TIME (12 Vout models)
90
NOTES: 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HPR10XX devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steady-state value. 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs.
Total Load Capacitance (uF)
80 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS)
SAFE OPERATING AREA
HPR10XX
REV D
8/2007
Page 3
ORDERING INFORMATION
HPR 10XX /H Device Family HPR Indicates DC/DC Converter Model Number Selected from Table of Electrical Characteristics Screening Option
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation.....................................................490mW Short Circuit Duration......................................................Momentary Lead Temperature (soldering, 10 seconds max)..................+300°C
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device’s body will not be compromised and internal temperatures within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering.
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications.
Page 4
HPR10XX
REV D
8/2007