Product Data Sheet 750 WATT AC/DC POWER SUPPLY KX750 DESCRIPTION The KX750 is a low profile, 750 watt, power factor corrected, triple output power supply utilizing a half-bridge topology operating at 250kHz. The compact design yields a power density in excess of 6 watts per cubic inch. Universal input and power factor correction to EN61000-3-2 make the KX750 an excellent choice for product applications with woldwide markets. In addition, the KX750 carries UL, CSA and TUV approvals, and complies with FCC and VDE Class B EMI requirements. Optional active current sharing on all three outputs simplifies N+1 redundant applicaitons. Remote sensing capability is standard on all outputs and will compensate for up to 0.7V line drop. All outputs are fully isolated, regulated, and current limited FEATURES Active Power Factor Correction to EN61000-3-2 3.3V Main Output FCC/VDE Class B EMI Filter Active Current Sharing Optional Fully Isolated and Regulated Outputs Compact Size: 12” x 5” x 2” 75% Efficiency Typical > 6 Watts Per Cubic Inch Optional Fan Mounted On Cover Optional Current Sharing On All Outputs AGENCY APPROVALS Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 KX750 4/99 REV B Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 Page 1 Input Specifications Parameter Operating Range Inrush Current Conditions 47-63Hz 120VAC, cold start 240VAC, cold start Min 90 Typ Max 264 40 80 Units VAC APK APK % Efficiency Power Factor Correction (PFC) Nominal line and full load Meets EN61000-3-2 75 0.99 Remote Sense Remote Sense is provided on all outputs and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short, and reversal. Remote On/Off The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.25V, ±0.8 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Reverse Voltage Protection All outputs are protected to rated load. Transient Response The peak output voltage excursion on the main output will not exceed 2% and will recover within 1% in 200 µSec for a 25% load step change. Output Isolation All outputs are fully isolated. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 5msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation referenced to (-) sense terminal. Consult the factory for other options. DC Power Good Signal Upon a ±10% loss of regulation on any output, the DC Good signal drops to a logic zero referenced to (-) sense terminal. Consult the factory for other options. Over Temperature Protection Internal thermal switch turns off power supply if overheating occurs and automatically restarts when temperature drops below threshold. Safety UL Recognized: UL File Number 14675 (1950 & 1012) CSA Certified: CSA File Number LR9070-154C (C22.2 No. 234-M90, Level 6) TUV License Number:R9576032 (EN60950) (IEC950) Cooling The unit is designed to operate with 30 CFM of airflow. Page 2 KX750 4/99 REV B Output Voltages and Maximum Rated Loads MODEL NUMBER KX750-F3A KX750-F2B KX750-F1C OUTPUT #1 IMAX VOUT ± 5V ± 5V ± 5V 100A 100A 100A OUTPUT #2 VNOM IMAX ± 12V ± 12V 20A 20A OUTPUT #3 VNOM IMAX ± 12V 20A NOTE: Total power not to exceed 750 watts. Output Specifications Parameter Regulation Line Load Cross Minimum Load Output #1 Outputs #2 & #3 Hold-Up Time 5.0A 1.0A >20mSec at Full Load + 0.1% + 0.2% + 0.2% Limits Main Output Outputs #2 - 3 + 0.2% + 0.4% + 0.2% Parameter Voltage Adustment Range PARD Temperature Operating Conditions Nominal line on all outputs 20 MHz bandwidth Min Typ ±5 Max 1 Units % % P-P 0 Derates 20W/°C 50 -20 Non-condensing All outputs after half hour warm-up 0 50 70 +85 95 ± 0.02 °C °C °C % %/°C Storage Humidity Range Temperature Coefficient (TC) KX750 4/99 REV B Page 3 Mechanical Side View - Remote Sense #2 + Remote Sense #2 Current Sense Bus #2 - Remote Sense #3 + Remote Sense #3 Curent Sense Bus #3 + Remote Sense #1 - Remote Sense #1 Sync I/O AC Power Fail Alarm Status/Control Return DC Power Good Remote Inhibit Current Sense Bus #1 KX750 4/99 REV B Side View Top View Bottom View NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.70”. COOLING: The KX750 is designed to operate with 30 CFM airflow in 50°C ambient termperature. SHOCK AND VIBRATION: The KX750 meets the requirements of MIL-STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I). WEIGHT: Approximately 6 lbs. Pin Specifications Terminal Block 1 POS 1 2 3 FUNCTION AC Line AC Neutral Ground Connector Specifications Terminal Block 2 POS 1 2 3 4 FUNCTION -V2 +V2 -V3 +V3 PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J9 Connector Molex No. 22-08--1140 FUNCTION Standard Options are shown, consult factory for other available options. The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications. Page 4
KX750-F2B
1. 物料型号:KX750,这是一个750瓦的交流/直流电源供应器。

2. 器件简介:KX750是一款低配置文件、750瓦的电源因数校正三输出电源供应器,使用半桥拓扑结构在250kHz下运行。其紧凑设计使得功率密度超过每立方英寸6瓦。具有全球通用输入和符合EN61000-3-2标准的功率因数校正,使其成为全球市场产品应用的理想选择。此外,KX750还通过了UL、CSA和TUV认证,并符合FCC和VDE B级EMI要求。可选的主动电流共享功能简化了N+1冗余应用。所有输出均标准具备远程感应能力,能够补偿高达0.7V的线路下降。所有输出完全隔离、调节和限流。

3. 引脚分配: - 终端块1:1号位为交流线,2号位为交流中性线,3号位为地线。 - 终端块2:1号位为-V2,2号位为+V2,3号位为-V3,4号位为+V3。 - J9连接器:1至14号引脚分别对应不同的功能,如远程感应、电流感应总线、同步I/O、交流电源失效报警、状态/控制返回、直流电源良好、远程禁止和电流感应总线等。

4. 参数特性: - 输入规格:工作范围90至264V交流电,功率因数校正满足EN61000-3-2标准,效率为75%。 - 远程感应:所有输出均提供远程感应,能够补偿0.7V线路下降。 - 过电压保护:输出#1为6.25V,±0.8V直流电。 - 过电流保护:所有输出均有单独电流限制,故障移除后自动恢复。 - 反向电压保护:所有输出均保护至额定负载。

5. 功能详解:KX750具备主动功率因数校正、完全隔离和调节输出、紧凑尺寸、75%的典型效率、每立方英寸超过6瓦的功率密度、可选风扇安装在外壳上、可选所有输出的电流共享等功能。

6. 应用信息:KX750适用于需要全球市场的产品应用,特别是在需要高功率密度和全球通用输入的场合。

7. 封装信息:尺寸为12英寸 x 5英寸 x 2英寸,风扇安装在外壳上会增加1.70英寸的高度。KX750设计为在50°C的环境温度下以30CFM的气流运行。满足MIL-STD-810D的冲击和振动要求,重量约为6磅。
KX750-F2B 价格&库存