NMR SERIES
Isolated 1W Single Output DC-DC Converters
SELECTION GUIDE
Nominal Input Voltage
Output Voltage
Output Current
Input Current at Rated Load
MTTF1
Order Code
NMR100
(V) 5
(V) 5
(mA) 200
(mA) 290
(%) 69
(pF) 28
kHrs 1322
NMR101
5
12
83
260
77
33
235
FEATURES s Wide Temperature Performance at Full 1 Watt Load, –40°C to 85°C s Industry Standard Pinout s 1kVDC Isolation s Efficiency to 79% s Power Density up to 0.90W/cm3 s 5V & 12V Input s 5V, 12V & 15V Output s Footprint of 1.17cm 2 s UL 94V-0 Package Material s No Heatsink Required s Internal SMD Construction s Toroidal Magnetics s Fully Encapsulated s No External Components Required s MTTF up to 1.6 Million Hours s Custom Solutions Available s No Electrolytic or Tantalum Capacitors DESCRIPTION
The NMR series of industrial temperature range DC-DC converters are the standard building blocks for on-board distributed power systems. They are ideally suited for providing single rail supplies on primarily digital boards with the added benefit of galvanic isolation to reduce switching noise. Surface mount technology and advanced packaging materials produce rugged reliable performance over an extended temperature range from –40°C to 85°C.
NMR102
5
15
67
253
79
40
127
NMR106
12
5
200
121
69
36
515
NMR107
12
12
83
110
76
58
184
NMR108
12
15
67
110
76
56
111
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Voltage Range Continuous operation, 5V input types Continuous operation, 12V input types Reflected Ripple Current
4.5 10.8
5 12 40
5.5 13.2 60
V mA p-p
OUTPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
High V IN to low V IN 10% load to rated load, 5V output types Load Regulation 10% load to rated load, 12V output types 10% load to rated load, 15V output types Ripple & Noise BW=DC to 20MHz
Rated Power2 Voltage Set Point Accuracy Line Regulation
TA= –40°C to 85°C See tolerance envelope 1.0 12.5 6.9 6.5 30
1.0
W
1.2 13.4 7.7 7.5 50
%/% % mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit duration 3 Internal power dissipation Lead temperature 1.5mm from case for 10 seconds Input voltage V IN , NME05 types Input voltage V IN , NME12 types 1 second 550mW 300°C 7V 15V
www.dc-dc.com
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 2 See derating curve 3 Supply voltage must be discontinued at the end of the short circuit duration. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NMR SERIES
Isolated 1W Single Output DC-DC Converters
ISOLATION CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage Resistance
Flash tested for 1 second Viso=1000VDC
1000 10
VDC GΩ
GENERAL CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Switching Frequency
5V input types 12V input types
110 160
kHz
TEMPERATURE CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Specification Storage Case Temperature Above Ambient Cooling
All output types 5V output types All other output types Free air convection
-40 -50 33 28
85 130
°C °C °C
PERFORMANCE CHARACTERISTICS
tolerance envelope +10%
+5% V nominal
2.0 +2.5% -2.5% -7.5% 1.0 0.5 0 1.5
temperature derating graph
Safe Operating Area
10
50 Output Load Current (%)
100
-40
0 50 100 Ambient Temperature (°C)
150
MECHANICAL DIMENSIONS
7 Pin SIP
19.50 1.88±0.50
6.00 10.0
NMR100
XYYWWi
PIN 1 VIN 2 GND 4 0V 6 +V Weight: 2.1g
1.25
0.55 0.45 12.70 0.55 0.45
0.30 0.20
4.60 3.60
12
4
2.54
6
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch and within ±0.25mm of true position.
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use. © C&D Technologies (NCL) Limited 2001 NDC NMR.3 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited. Instructions for use are available from www.dc-dc.com
C&D Technologies (NCL) Ltd Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: info@cdtechno-ncl.com www: http://www.dc-dc.com
C&D Technologies (NCL), Inc. 5816 Creedmoor Road, Raleigh NC 27612, USA Tel: +1 (919) 571-9405 Fax: +1 (919) 571-9262 email: info@us.cdtechno-ncl.com