NTA SERIES
Isolated 1W Dual Output SM DC-DC Converters
SELECTION GUIDE
Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Efficiency Isolation Capacitance MTTF1
Order Code5
NTA0312M NTA0315M NTA0505M NTA0509M NTA0512M
(V) 3.3 3.3 5 5 5 5 12 12 12 12
(V) 12 15 5 9 12 15 5 9 12 15
(mA) ±42 ±33 ±100 ±55 ±42 ±33 ±100 ±55 ±42 ±33
(mA) 390 392 290 267 260 256 121 113 111 110
(%) 77 77 69 75 77 78 69 74 75 76
(pF) 40 42 33 38 44 43 50 72 89 100
kHrs 375 206 1697 682 343 188 559 375 243 154
FEATURES ■ Wide Temperature Performance at Full 1Watt Load, -40°C to 85°C ■ Lead Frame Technology ■ CECC00802 Reflow (280°C) ■ Dual Isolated Output ■ 1kVDC Isolation ■ Efficiency to 78% ■ Power Density 1.36W/cm3 ■ 5V & 12V Input ■ 5V, 9V, 12V and 15V Output ■ Footprint Over Pins 1.64cm2 ■ UL 94V-0 Package Material ■ No Heatsink Required ■ Internal SMD Construction ■ Toroidal Magnetics ■ Plastic Encapsulated ■ MTTF up to 2.1 Million Hours ■ Custom Solutions Available ■ Multi Layer Ceramic Capacitors ■ Lead Free Compatible DESCRIPTION
The NTA series of miniature surface mounted DC-DC Converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitry. The devices are fully compatible with CECC00802 to 280°C which allows them to be placed and reflowed with IC’s, thus reducing time and cost in production. Co-planarity of the lead positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged.
NTA0515M NTA1205M NTA1209M NTA1212M NTA1215M
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Voltage Range Reflected Ripple Current
Continuous operation, 3V input types 2.97 Continuous operation, 5V input types 4.5 Continuous operation, 12V input types 10.8
3.3 5 12 41
3.63 5.5 V 13.2 47 mA p-p
OUTPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Rated Power2 Voltage Set Point Accuracy Line regulation
TA = -40°C to 85°C See tolerance envelope 1.0 10 6.5 6.0 6.0 50 35 50 65
1.0
W
High VIN to low VIN 10% load to rated load, 5V output types Load Regulation3 10% load to rated load, 9V output types 10% load to rated load, 12V output types 10% load to rated load, 15V output types BW=DC to 20MHz, 5V output types Ripple and Noise BW=DC to 20MHz, 9V output types BW=DC to 20MHz, 12V output types BW=DC to 20MHz, 15V output types
1.2 12 8 8.5 7.0 100 80 110 110
%/% %
mV p-p
ABSOLUTE MAXIMUM RATINGS
Short circuit duration4 Internal power dissipation Lead temperature 1.5mm from case for 10 seconds Input Voltage VIN , NTA03 types Input Voltage VIN , NTA05 types Input voltage VIN , NTA12 types
1 2 3 4 5
1second 550mW 300°C 5.5V 7V 15V
Calculated using MIL-HDBK-217F with nominal input voltage at full load. See derating curve. 12V input types have typically 3% less load regulation change. Supply voltage must be discontinued at the end of the short circuit duration. If components are required in tape and reel format suffix order code with -R, e.g. NTA0505M-R
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.cdpoweronline.com
NTA SERIES
Isolated 1W Dual Output SM DC-DC Converters
ISOLATION CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage Resistance
Flash tested for 1 second Viso=1000VDC
1000 10
VDC GΩ
GENERAL CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Switching Frequency
3V input types 5V & 12V input types
100 115
kHz
TEMPERATURE CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Specification Storage Case Temperature Case Temperature above ambient Cooling
All output types NTA312M, NTA315M 5V output types All other output types Free air convection
-40 -55 19 46 35
85 125
°C °C °C
PERFORMANCE CHARACTERISTICS
tolerance envelope +10%
+5% V nominal
2.0 +2.5% -2.5%
Output Power (W)
temperature derating graph
1.5 1.0 0.5 0
Safe Operating Area 85°C
Output Voltage
-7.5%
10
50 Output Load Current (%)
100
-40
0 50 100 Ambient Temperature (°C)
150
MECHANICAL DIMENSIONS
15.24 10.16
18 16 14 12 10
DETAIL A
REFERENCE PLANE
P
11.20 7.70 10.40
1
NTA0505M
XYYWW
3 5 7 9
0.5
1.50 1.20 10 PINS 0.65 0.2 M S 0.55 P 2.10
±5.00°
2.54
DETAIL A S 1.875 MAX
SEATING PLANE
6.60 (6.35) (5.95) 5.85
0.25 0.10 0.1 S
PIN 1 GND 3 VIN 5 NA 7 0V 9 -V 10 NA 12 +V 14 NA 16 NA 18 NA Weight: 1.53g
0.30 0.20
2.79MAX
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch.
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use. © C&D Technologies (NCL) Limited 2003 NDC NTA.3 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited. Instructions for use are available from www.cdpoweronline.com C&D Technologies (NCL) Ltd Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545 email: info@cdtechno-ncl.com www.cdpoweronline.com C&D Technologies Inc. 3400 E Britannia Drive, Tucson, Arizona 85706, USA Tel: +1 (800) 547-2537 Fax: +1 (520) 741-4598 email: sales@cdtechno.com