0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PX500-U4C

PX500-U4C

  • 厂商:

    CANDD

  • 封装:

  • 描述:

    PX500-U4C - 500 WATT AC/DC POWER SUPPLY - C&D Technologies

  • 数据手册
  • 价格&库存
PX500-U4C 数据手册
Product Data Sheet 500 WATT AC/DC POWER SUPPLY PX500 DESCRIPTION The PX500 is a compact 500 watt Power Factor Corrected, multiple output power supply. All outputs are fully isolated and regulated. Active current sharing circuitry, together with control functions and alarm options, simplifies N+1 and redundant applications. Fan and disk drive applications are handled by the peak current ratings of the auxiliary outputs. FEATURES ! Active Power Factor Correction ! High Surge Current Auxiliary Outputs ! Fully Isolated Outputs ! One, Two, Three or Four Output Models ! N + 1 Current Sharing ! FCC/VDE Class B EMI Filter Standard ! Fast Transient Response ! Optional Cover With Fan Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 PX500 1/98 REV A Page 1 Input Specifications Parameter Operating Range Inrush Current Limiting 120VAC, cold start 240VAC, cold start Efficiency 120VAC, full load 240VAC, full load Power Factor Correction (PFC) Meets IEC 1000-4-7/EN61000-2-3 (formerly IEC 555-2) 70% 75% 0.99 30 70 APK APK Conditions 47-63 Hz Min 90 Typ Max 264 Units VAC Remote Sense Remote Sense is provided on Output #1 and will compensate for 1.0V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off (Optional) The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V, ±0.5 VDC The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 400 µsec for a 25% step load. Output Isolation All outputs are fully isolated. N+1 Load Share Output #1 has active load sharing circuitry. Units will load share within 1.0% of Maximum Rated Load. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 5msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options. Over Temperature Protection Internal thermal switch turns off power supply if overheating occurs and automatically restarts. Automatic restart when temperature drops below threshold. Safety UL Recognized: UL File Number E14675 (1950 & 1012) CSA Certified: CSA File Number LR 9070-154C (C22.2 No9. 234-M90, Level 6) TUV License Number: R9576030 (EN60950) (IEC950) Cooling The unit is designed to operate with 40 CFM of airflow. Page 2 PX500 1/98 REV A Output Voltages and Maximum Rated Loads OUTPUT #1 VOUT IMAX ±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V 80A 80A 80A 80A 80A 80A 80A 80A 80A 80A 80A 80A MODEL NUMBER PX500-U3A PX500-U3B PX500-U4C PX500-U4D PX500-U4E PX500-U4F PX500-U4G PX500-U4H PX500-U4I PX500-U4J PX500-U4K PX500-U4L OUTPUT #2 VNOM IMAX/IPK ± 12V ± 15V ± 12V ± 12V ± 12V ± 15V ± 15V ± 12V ± 12V ± 24V ± 5V ± 12V 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 4A 15A 12A OUTPUT #3 VNOM IMAX/IPK ± 12V ± 15V ± 12V ± 12V ± 12V ± 15V ± 15V ± 12V ± 15V ± 24V ± 12V ± 12V 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 12A/15A 4A 12A 12A OUTPUT #4 VNOM IMAX ± 5V ± 24V ± 12V ± 5V ± 24V ± 5.2V ± 5.2V ± 5V ± 12V ± 3.3V 4.0A 3.0A 4.0A 4.0A 3.0A 10.0A 10.0A 3.0A 4.0A 10.0A Note: Peak current ratings are for 10sec maximum. Total power not to exceed 500 watts. Output Specifications Parameter Regulation Line Load Cross Minimum Load Output # 1 Outputs #2, #3, #4 Hold-Up Time 4.0A 0.0A 20mSec at Full Load ± 0.1% ±0.25% ±0.1% Limits Parameter Voltage Adustment Range PARD Temperature Operating Conditions 20 MHz bandwidth Min Typ ±5 Max 1 Units % % P-P 0 Derates to half power 50 70 °C °C °C % /°C Storage Temperature Coefficient (TC) After half hour warm-up -20 ± 0.02 +85 PX500 1/98 REV A Page 3 Mechanical TOP VIEW 0.700 8.500 2.12 0.063 COVER 0.550 1 2 3 TB2 3.900 1 2 3 4.850 4 5 6 J9 5V TB1 10.000 5V Return Maximum depth of mounting screws is 0.156” NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30”. COOLING: The PX500 is designed to operate with 40 CFM airflow. SHOCK AND VIBRATION: The PX500 family meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Pocedure I; Shock-Method 516.3 Procedure I). WEIGHT: Approximately 4 lbs. Terminal Block 1 POS FUNCTION 1 2 3 Ground AC Neutral AC Line Terminal Block 2 POS 1 2 3 4 5 6 FUNCTION -V4 +V4 -V3 +V3 -V2 +V2 1 2 3 4 5 J9 Connector PIN FUNCTION - Sense + Sense Current Share Remote Inhibit Power Fail J9 Connector Molex No. Connector 22-28-1050 Standard Options are shown, consult factory for other available options. The information provided herein is believed to be reliable; however, C&D Technologies assumes no responsibility for inaccuracies or omissions. C&D Technologies assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D Technologies does not authorize or warrant any C&D Technologies product for use in life support devices/systems or in aircraft control applications. C&D Technologies, Iso-ThermoFlex and T.E.A.M. Q are trademarks of C&D Technologies Corporation. Page 4 PX500 1/98 REV A
PX500-U4C 价格&库存

很抱歉,暂时无法提供与“PX500-U4C”相匹配的价格&库存,您可以联系我们找货

免费人工找货