Input Specifications
Parameter
Operating Range Inrush Current Limiting 36VD 72VDC Efficiency 48 VDC, at full load 70 25 50 APK APK %
Conditions
DC
Min
36
Typ
48
Max
72
Units
VDC
Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off (Optional) The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V ± 0.5 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Active Inrush Current Limiting Inrush current is independent of ambient temperature.
Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 μsec for a 25% load step change. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety Safety certified to UL/CUL to 1950, File Number E131694 TUV to EN60950/IEC950. Cooling The unit is designed to operate with 30 CFM of airflow.
Page 2
DNX301 4/2002 REV B
Output Voltages and Maximum Rated Loads
OUTPUT #1 VOUT IMAX
±5V ±5V ±5V ±5V ±5V ±5V ±5V ±5V 45A 45A 45A 45A 45A 45A 45A 45A
MODEL NUMBER
DNX301-U3A DNX301-U3B DNX301-U4C DNX301-U4D DNX301-U4E DNX301-U4F DNX301-U4G DNX301-U4H
OUTPUT #2 VNOM IMAX/IPK
± 12V ± 15V ± 12V ± 12V ± 12V ± 15V ± 15V ± 15V 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A
OUTPUT #3 VNOM IMAX/IPK
± 12V ± 15V ± 12V ± 12V ± 12V ± 15V ± 15V ± 15V 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A
OUTPUT #4 VNOM IMAX
± 5V ± 24V ± 12V ± 5V ± 24V ± 12V 3.0A 1.5A 3.0A 3.0A 1.5A 3.0A
Note: Maximum current ratings are for 10sec maximum. Total power not to exceed 300 watts.
Output Specifications
Parameter
Regulation Line Load Cross Minimum Load Output #1 Auxiliary Outputs 3.0A 0.1A ± 0.03% ±0.25% ±0.05%
Limits
Parameter
Voltage Adustment Range PARD Temperature Operating Storage Temperature Coefficient (TC)
Conditions
20 MHz bandwidth
Min
Typ
±5
Max
1
Units
% % P-P
0 -20 After half hour warm-up ± 0.02
50 +85
°C °C %/°C
DNX301 4/2002 REV B
Page 3
Mechanical
TOP VIEW 0.25 0.55 8.50 1.95 0.040
COVER
1
TB2
3.90
4.85
1 J9
1
OUTPUT NO. 1
5V RETURN
TB1
9.00
5V 6-32 THD 4 PLC’S Maximum depth of mounting scres is 0.156 inches
NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30”. COOLING: The DNX301 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The DNX301 meets the requirements of MIL STD-810D. WEIGHT: Approximately 3 lbs.
Terminal Block 1
POS 1 2 3 FUNCTION DC + DC Ground
Terminal Block 2
POS 1 2 3 4 5 6 FUNCTION -V2 +V2 -V3 +V3 -V4 +V4
J9 Connector Molex No. 22-28-1090
PIN 1 2 3 4 5 6 7 8 9 FUNCTION + Sense - Sense N/C N/C Start Up Sync. N/C Remote Inhibit Current Share Control Signal Rtn