0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TPS_PX500

TPS_PX500

  • 厂商:

    CANDD

  • 封装:

  • 描述:

    TPS_PX500 - AC/DC 500W Multiple Output Power Supply - C&D Technologies

  • 数据手册
  • 价格&库存
TPS_PX500 数据手册
PX500 Series AC/DC 500W Multiple Output Power Supply SELECTION GUIDE Model Number PX500U3ABFHPHM PX500U3BBFHPHM PX500U4CBFHPHM PX500U4CBFHPHMC PX500U4EBFHPHM PX500U4HBFHPHM PX500U4HBFHPHMC PX500U4HBVHPHM PX500U4LBFHPHM PX500U4HBVHPHMC PX500U4LBFHPHMC Output 1 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A 5V@80A Output 2 2V@2A 5V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A Output 3 2V@2A 5V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A 2V@2A Output 4 --5V@4A 5V@4A 2V@4A 5.2V@0A 5.2V@0A 5.2V@0A 5.2V@0A 3.3V@0A 3.3V@0A NA NA NA Yes NA NA Yes NA Yes NA Yes FEATURES n Industry Standard 2"x5"x0" Package n 500W Power at 0-50ºC n Active Power Factor Correction n Efficiency up to 75% n Power Fail Warning Signal n 80A Main Output n Remote Sense on Main Output n Remote Inhibit Control n Class B conducted EMI Performance n Global 90-264VAC Input n Active Current Sharing on Output V n RoHS Compliant UCdTl D ROment Mo e P TEr Replace OLEry fo BSct Facto Oa INPUT CHARACTERISTICS Parameter Input Operating Voltage Input Current Power Factor Inrush Current 240Vac 20Vac Conditions Min 90 47 Typ Max 264 63 7.0 Units Vac Hz Arms Apk Apk nt CoInput Frequency 0.99 70 30 DESCRIPTION The PX500 is a family of 500W, multiple-output power supplies developed for a broad range of applications. All outputs are fully isolated and regulated for either positive or negative ground reference. The outputs can also be connected in series to develop higher voltages or in parallel to develop higher currents. The two-switch forward topology used in the PX500 supplies has been field-proven for high reliability. The mag-amp post-regulators used on the auxiliary outputs will support high peak currents. With a global input of 90-264VAC, safety agency approvals to UL950, CSA C22.2 No. 234-M90, and EN60950, EMI compliance to Class B FCC Part 5, the PX500 was designed with globallydeployed product applications in mind. The PX500 is available in various output voltage/ current configurations and with various cover options. Additional features include remote sense compensation, a power fail warning signal, as well as output inhibit. Several models of the PX500 are also available with RoHS compliance. OUTPUT CHARACTERISTICS Parameter Output Power Temperature Coefficient Voltage Regulation Minimum Load Minimum Load PARD (Vo) Output Voltage Adjustment Transient Excursion (Vo) Transient Recovery (Vo) Output Holdup Time Isolation, Pri-Sec Isolation, Pri-Chassis Isolation, Sec-Chassis Current Share Tolerance Remote Sense Comp. (Vo) Output V; Io>25% Conditions All line & environmental After 30min warm up Line Load Cross V V2, V3, V4 20MHz bandwidth All outputs 25% load step, A/μsec max slew 25% load step, A/μsec max slew Full load, low line 3 .5 500 0 000 20 -5 -3 -0. -0.5 -0. 4 0  +5 +3 400 Min Typ Max 500 0.02 +0. +0.5 +0. Units W %/ºC %Vo %Vo %Vo A A %Vnom %Vnom %Vo μsec msec kVac kVac Vac % mV ISO9001 CERTIFIED www.cd4power.com PCX500 Series Rev 07/2006 Page  of 4 PX500 Series AC/DC 500W Multiple Output Power Supply GENERAL CHARACTERISTICS Parameter Efficiency Switching Frequency MTBF Weight Conditions Full load, 240Vac PFC Converter Mil-HDBK-27E Unpackaged 3 4 Min Typ 70 00 Max 75 Units % kHz khrs lbs PROTECTION Parameter Output OverVoltage Protection Output Overload Protection Output Power Limit Thermal Shutdown Input Protection Conditions/Response V; Latching; cycle AC input to re-start All outputs; individual current limit; automatic recovery Automatic Recovery Inception Min 6.0 Nom 6.5 20 550 00 0 Max 7.0 Units V %Io W ºC A ENVIRONMENTAL CHARACTERISTICS Parameter Ambient Operating Temperature Ambient Storage Temperature Operating Humidity Storage Humidity Altitude UCdTl D ROment Mo e P TEr Replace OLEry fo OBSct Facto a Internal line fuse; Littlefuse 3200 or equivalent Conditions De-rate output power linearly above 50ºC to 250W at 70ºC Non-condensing Min 0 -20 0 5 -200 -200 Typ +50 Max +70 +85 90 90 0000 50000 Units ºC ºC % % ft ft t Non-condensing Con Storage Operating. De-rate operating ambient temperature by 2Cº per 000ft above 5000ft. ELECTROMAGNETIC COMPATIBILITY (EMC) Characteristic Input Current Harmonics Conducted Emissions Compliance EN6000-3-2, Class A CFR Title 47, Part 5, Sub-part B, Class B (when the cover option is employed) EN55022, Class A CERTIFICATIONS Agency/Characteristic UL CSA TUV CE RoHS SELV Vibration Shock Standard UL950 & UL02 (File Number E4675) CSA 22.2 No. 234-M90, Level 6 (File Number LR 9070-54C) EN60950 (License Number R9576030) LVD Directive; self-certified EN Directive 2002/95/EC; self-certified (see selection guide table on page  for compliance) Self-certified MIL-STD-80D, Method 54.3, Procedure I; self-certified MIL-STD-80D, Method 56.3, Procedure I; self-certified www.cd4power.com PCX500 Series Rev 07/2006 Page 2 of 4 PX500 Series AC/DC 500W Multiple Output Power Supply MECHANICAL DIMENSIONS (Top-Mounted Fan Cover, Option “F”) UCdTl D ROment Mo e P TEr Replace OLEry fo BSct Facto Oa MECHANICAL DIMENSIONS t Con (End-Vented Fan Cover, Option “V”) www.cd4power.com PCX500 Series Rev 07/2006 Page 3 of 4 PX500 Series AC/DC 500W Multiple Output Power Supply MODEL NUMBERING PX 500 U x x B x H P H M Product Family Maximum continuous output power in Watts U-Channel chassis Number of outputs (3 or 4) Output voltage & current configuration (see Selection Guide table on page  for details) Conducted emissions compliance level Cover Options (F, V) Remote Inhibit/Enable Logic (Logic  enables output) Power Factor Corrected Power Fail Warning Logic (Logic  indicates AC applied) Active current sharing on Main output (V) CONNECTIONS INPUT (Terminal Block TB) TB- TB-2 TB-3 OUTPUT (Terminal Block TB2) TB2- TB2-2 TB2-3 TB2-4 TB2-5 TB2-6 CONTROL (Molex PN 22-28-050) J- J-2 J-3 J-4 J-5 Ref Chassis Ground Input Neutral Input Line Ref Output 4 Return Output 4 Output 3 Return Output 3 Output 2 Return Output 2 Ref Remote Sense + Remote Sense V Current Share Remote Inhibit AC Power Fail Warning SS+ CS RI PFW -V4 +V4 -V3 +V3 -V2 +V2 G N L SAFETY AGENCY RATINGS Input Voltage Input Current 20/240Vac 8A-4A UCdTl ODnt Mo e R E Pplaceme LErTfor Re BScOacto y O a tF t Con C&D Technologies, Inc. reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our website to ensure that you have the current and complete specification for your product before use. © C&D Technologies 3400 E Britannia Drive, Tucson, Arizona 85706, USA C&D Technologies (NCL) Ltd C&D Technologies  Cabot Boulevard, Mansfield, Tanners Drive, Blakelands North Milton Keynes MK4 5BU, UK MA 02048-5, USA Tel: + (508) 339-3000 Fax: + (800) 233-2765 email: sales@cdtechno.com Tel: +44 (0)908 65232 Fax: +44 (0)908 67545 email: info@cdtechno-ncl.com C&D Technologies, Inc. 2006 Tel: + (800) 547-2537 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any Fax: + (520) 74-4598 way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior email: pedmktg@cdtechno.com written permission from C&D Technologies, Inc. Instructions for use are available from www.cd4power.com www.cd4power.com PCX500 Series Rev 07/2006 Page 4 of 4
TPS_PX500 价格&库存

很抱歉,暂时无法提供与“TPS_PX500”相匹配的价格&库存,您可以联系我们找货

免费人工找货