Product Data Sheet
2000 WATT AC/DC POWER SUPPLY
TXD2000
DESCRIPTION
The TXD2000 Series is a flexible, modular, 2000 Watt design offering two high current outputs in a 5 x 8 x 12 package. Output voltages from 2.5 VDC through 48 VDC are standard. With Power Factor Correction, EMI compliance to FCC and CISPR22, CE Mark and immunity to EN61000-4, the TXD2000 Series is ready for global deployment. Standard features include Remote Sense Compensation, Output Voltage Adjustment, Active Current Sharing, Remote Inhibit, Power Fail Warning, DC OK Signal and Thermal Shutdown. An optional ORing diode is offered on models with an output voltage of 12 VDC or above.
FEATURES
Wide Range Input of 90-264VAC, 1000 Watts, High Range Input of 180-264VAC, 2000 Watts, Harmonic Correction to EN61000-3-2 ont Active Current Sharing No Load Operation Optional ORing Diode 70-80% Efficiencies FCC / CISPR 22 Class A EMI Filtering Self-Cooled 5”x 8”x 12” Chassis EN61000-4 Immunity
UCdTl D ROment Mo e E Pplace LErTfor Re BScOacto y O a tF
C
AGENCY APPROVALS
Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 Page 1
TXD2000 2/2000 REV A
Input Specifications
Parameters
Operating Range 1000W 2000W Inrush Current Efficiency Holdup Power Factor
(1)
Conditions
47-63Hz 47-63Hz 120VAC, 250C, cold start 240VAC, 250C, cold start Nominal line, full load Full load Full load
Min
90 180
Typ
Max
264 264 80 160
Units
VAC VAC Apk Apk % m sec
70 20
75 0.99
80
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltage Modules and Maximum Rated Load
Output Output Voltage Voltage Code Voltage
A B C D E F G H J 5.0 12.0 15.0 18.0 24.0 28.0 36.0 48.0 3.3
Output Current (Maximum Continuous)
200A 83A 67A 55A 42A 36A 28A 21A
Output Power (Maximum Continuous)
1000W 1000W 1000W 1000W 1000W 1000W 1000W 1000W 800W 600W
UCdTl D ROment Mo e P TEr Replace OLEry fo S to Output SpecificationsOB ct Fac a
20.0 2.5 40A K L 182A 200A 500W
Parameter
Conditions Co
nt
Min
Typ
Max
1000
Units
Watts Watts % % Amps pk-pk %/0C
Output Power 90-264VAC 180-264VAC Voltage Adjustment Range Output Regulation Minimum Load PARD Temperature Coefficient
All environmental and line conditions Limited by output module selection Relative to nominal output voltage Line, load or cross 0 Measured at output terminals, 20MHz 00 to 500C +0.2 50 mv or 1% +5 +0.2 2000
Environmental Specifications
Parameter
Ambient Temperature (Operating) Ambient Temperature Altitude (Operating) Altitude (Non-operating) Shock Vibration Cooling
Conditions
Output de-rated linearly to 50% of rated capacity between 500C and 700C Non-operating
Min
0 -50 -200 -200
Typ
Max
+70 +85 +10,000 +50,000
Units
0 0
C C
Feet Feet
Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test The TXD2000 is provided with internal cooling fans.
Page 2
TXD2000 2/2000 REV A
Product Features
Features
Remote Sense Active Current Sharing ORing Diode OVP Thermal Shutdown DC OK Signal Power Fail Warning Remote Inhibit
Characteristic
500mV compensation Single Wire; 5% current share if outputs are over 25% of rated load Optional (not available on modules below 12V) 125% of nominal (+7.5%) Automatic Restart Logic “1” when output is within +3% of nominal Transition to Logic “0” at least 5msec before loss of output regulation Logic “0” applied will inhibit output (referenced to –Sense terminal)
Product Compliances
Approval
UL and cUL VDE FCC CISPR 22 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-3-2 CE Mark
rd
Characteristic
UL1950, 3rd Edition EN60950 Class A requirements for conducted emissions Class A requirements for conducted emissions Electrostatic Discharge, Level 4 Electrical Fast Transients, Level 3 Input Surge Immunity, Level 3 Harmonic Currents, Class A Low Voltage Directive
(1)
UCdTl D Ordering Information ROment Mo e P TEr Replace OLEry fo OBSct Facto a
Notes: (1) UL1950, 3 Edition incorporates the requirements of CSA 950.
Model Designation
BASE MODEL
TXD2000
F
L
L
H
Chassis: “8” = 5” x 8” x 12”; “M” = modified
Output Voltage Module A: (see chart below) Output Voltage Module B: (see chart below) Standard Fan: “F”:
t Con
Remote Inhibit - TTL Logic Level “0” turns the power supply OFF: Power Fail Warning - TTL Logic Level “0” indicates AC is LOST: ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None: DC OK - TTL Logic Level “1” indicates DC is OK:
OUTPUT VOLTAGES A = 5V B = 12V C = 15V D = 18V E = 24V F = 28V
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications.
G = 36V H = 48V J = 20V K = 3.3V L = 2.5V
TXD2000 2/2000 REV A
Page 3
UCdTl D ROment Mo e P TEr Replace OLEry fo OBSct Facto a
t Con