TYPE MXH, X2, EMI, RFI Suppression Capacitors, Harsh Environment
THB 2,000 Hr @ 85 °C, 85% RH, and Vr, AEC-Q200
The MXH series is constructed of Metallized Polypropylene
Film encapsulated with self-extinguishing resin in plastic box
of material meeting the UL 94V-0 requirements. The series is
suitable for harsh environment conditions and is compliant with
with AEC-Q200 requirements. Applications include “across the
line” class X2 and EMI, RFI suppression.
Highlights
- THB 2,000 Hr @ 85˚C, 85% RH, and Vr
- Automotive Grade (AEC-Q200)
- High stability of capacitance
- High operating temperature: 110 °C
- Self-healing property
- Flame-retardant plastic case and resin
- Suitable for harsh environmental conditions
Specifications
Capacitance Range
0.1 µF to 15 µF
Capacitance Tolerance
±10 % (±20% optional)
Rated Voltage
305 Vac, 630 Vdc
Operating Temperature Range
–40 ºC to +110 ºC (+85 °C to 110 °C, voltage derating factor of
1.35% per Deg. C)
Life Expectancy
100,000h at rated voltage and hot spot temperature ≤85 °C
Voltage Between Terminals UTT
DC Voltage: 4.3Ur for 60s or √2(2UR + 1000Vac) VDC for 2s,
charge current must be 1A max.
Withstanding DC voltage (cut-off current 10mA) Rise time
100V/s
Voltage Between Terminals and Case UTC
2UR + 1500Vac, 60s at 20 °C
Dissipation Factor
0.001 @ 1KHz @ 20 ˚C
Insulation Resistance
C ≤0.33µF at 100V; 1 min. > 15000 MΩ
C >0.33µF at 100V; 1 min. > 5000 MΩ x µF
IEC Climatic Category
40/110/56 IEC60068-1
Damp Heat, Steady State
+40ºC / 93% RH @ rated voltage for 1,344 hrs +24/-0
Capacitance Change Rate: (ΔC/C): ≤±5%
DF Change (Δtgδ): ≤80*10-4 at 10 KHz (C ≤ 1µF)
DF Change (Δtgδ): ≤50*10-4 at 1 KHz (C > 1µF)
IR: ≥ 50% of initial limit
THB Rating
+85ºC / 85% RH @ rated voltage for 2,000hrs +24/-0
Capacitance Change Rate: (ΔC/C): ≤±10%
DF Change (Δtgδ): ≤240*10-4 at 10 KHz (C ≤ 1µF)
DF Change (Δtgδ): ≤150*10-4 at 1 KHz (C > 1µF)
IR: ≥ 50% of initial limit
Storage Conditions
-40 °C to +85 °C ≤24 months from date code, Average RH
≤70%
RoHS Compliant
Safety
Agency
Standard
File Number
UL
UL 60384-14
CSA-E60384-14
E171988
VDE
IEC 60384-14:2013
IEC 60384-14:2013/
AMD1:2016
40055249
CQC
IEC 60384-14
GB/T6346.14-2015
Pending
Construction Details
Case Material
Plastic UL 94V-0
Resin Material
Dry Resin UL 94V-0
Terminal Material
Pitch ≤27.5mm = Copper Clad Steel
Pitch ≥37.5mm = Tinned Copper Wire
CDE Cornell Dubilier • 1661 East Rodney French Blvd • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
TYPE MXH, X2, EMI, RFI Suppression Capacitors, Harsh Environment
THB 2,000 Hr @ 85 °C, 85% RH, and Vr, AEC-Q200
Dimensions
Size Code Table
Size
Dimensions
Pitch
Lead Wire
Lead
Code
W
Tol. ±
H
Tol. ±
T
Tol. ±
P
Tol. ±
Ød
Tol. ±
Tol ±0.05
E10
18
0.5
11
0.5
5
0.5
15
0.5
0.6
0.05
5
E11
18
0.5
12
0.5
6
0.5
15
0.5
0.6
0.05
5
E13
18
0.5
13.5
0.5
7.5
0.5
15
0.5
0.8
0.05
5
E14
18
0.5
14.5
0.5
8.5
0.5
15
0.5
0.8
0.05
5
E20
18
0.5
16
0.5
10
0.5
15
0.5
0.8
0.05
5
E21
18
0.5
19
0.5
11
0.5
15
0.5
0.8
0.05
5
G11
26
0.5
16.5
0.5
7
0.5
22.5
0.5
0.8
0.05
5
G20
26
0.5
19
0.5
10
0.5
22.5
0.5
0.8
0.05
5
G22
26
0.5
22
0.5
12
0.5
22.5
0.5
0.8
0.05
5
G23
26
0.5
23
0.5
13
0.5
22.5
0.5
0.8
0.05
5
G24
26
0.5
29.5
0.5
14.5
0.5
22.5
0.5
0.8
0.05
5
H11
32
0.8
18
0.8
9
0.8
27.5
0.5
0.8
0.05
5
H20
32
0.8
20
0.8
11
0.8
27.5
0.5
0.8
0.05
5
H22
32
0.8
24.5
0.8
13
0.8
27.5
0.5
0.8
0.05
5
H23
32
0.8
24
0.8
14
0.8
27.5
0.5
0.8
0.05
5
H27
32
0.8
28
0.8
18
0.8
27.5
0.5
0.8
0.05
5
H28
32
0.8
33
0.8
18
0.8
27.5
0.5
0.8
0.05
5
H30
32
0.8
37
0.8
22
0.8
27.5
0.5
0.8
0.05
5
N31
42
1
37
1
22
1
37.5
0.5
1
0.05
5
N30
42
1
40
1
20
1
37.5
0.5
1
0.05
5
N32
42
1
44
1
24
1
37.5
0.5
1
0.05
5
N40
42
1
45
1
30
1
37.5
0.5
1
0.05
5
Part Numbering System
MXH
Series
MXH
104
Capacitance
EIA Cap Code
104 = 0.1 µF
125 = 1.2 µF
156 = 15 µF
K
Tolerance
K = ±10% Standard
305
Voltage
305 = 305 Vac
E10
Case
See Size
CodeTable
CDE Cornell Dubilier • 1661 East Rodney French Blvd • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
TYPE MXH, X2, EMI, RFI Suppression Capacitors, Harsh Environment
THB 2,000 Hr @ 85 °C, 85% RH, and Vr, AEC-Q200
Ratings
Part Number
Cap (µF)
W
Dimensions
H
T
mm
mm
mm
P
Peak
Surge
dv/dt
Lead
Current
Current
mm
A
A
V/us
Wire
mm
305 VAC
MXH104K305E10
0.1
18
11
5
15
40
120
400
0.6
MXH154K305E11
0.15
18
12
6
15
60
180
400
0.6
MXH224K305E13
0.22
18
13.5
7.5
15
88
264
400
0.8
MXH224K305E14
0.22
18
14.5
8.5
15
88
264
400
0.8
MXH224K305G11
0.22
26
16.5
7
22.5
44
132
200
0.8
MXH274K305E14
0.27
18
14.5
8.5
15
108
324
400
0.8
MXH334K305E14
0.33
18
14.5
8.5
15
132
396
400
0.8
MXH334K305G11
0.33
26
16.5
7
22.5
66
198
200
0.8
MXH474K305E20
0.47
18
16
10
15
188
564
400
0.8
MXH474K305G11
0.47
26
16.5
7
22.5
94
282
200
0.8
MXH564K305E21
0.56
18
19
11
15
224
672
400
0.8
MXH564K305G20
0.56
26
19
10
22.5
112
336
200
0.8
MXH684K305E21
0.68
18
19
11
15
272
816
400
0.8
MXH684K305G20
0.68
26
19
10
22.5
136
408
200
0.8
MXH684K305H11
0.68
32
18
9
27.5
102
306
150
0.8
MXH824K305H11
0.82
32
18
9
27.5
123
369
150
0.8
MXH105K305G20
1
26
19
10
22.5
200
600
200
0.8
MXH105K305H20
1
32
20
11
27.5
150
450
150
0.8
MXH125K305G22
1.2
26
22
12
22.5
240
720
200
0.8
MXH155K305G23
1.5
26
23
13
22.5
300
900
200
0.8
MXH155K305H22
1.5
32
24.5
13
27.5
225
675
150
0.8
MXH185K305G24
1.8
26
29.5
14.5
22.5
360
1080
200
0.8
MXH185K305H22
1.8
32
24.5
13
27.5
270
810
150
0.8
MXH225K305G24
2.2
26
29.5
14.5
22.5
440
1320
200
0.8
MXH225K305H23
2.2
32
24
14
27.5
330
990
150
0.8
MXH275K305H27
2.7
32
28
18
27.5
405
1215
150
0.8
MXH335K305H28
3.3
32
33
18
27.5
495
1485
150
0.8
MXH395K305H28
3.9
32
33
18
27.5
585
1755
150
0.8
MXH475K305H30
4.7
32
37
22
27.5
705
2115
150
0.8
MXH685K305N31
6.8
42
37
22
37.5
680
2040
100
1
MXH685K305N30
6.8
42
40
20
37.5
680
2040
100
1
MXH106K305N32
10
42
44
24
37.5
1000
3000
100
1
MXH126K305N40
12
42
45
30
37.5
1200
3600
100
1
MXH156K305N40
15
42
45
30
37.5
1500
4500
100
1
CDE Cornell Dubilier • 1661 East Rodney French Blvd • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to
change. The customer is responsible for checking, confirming and verifying the extent to which the
Information contained in this datasheet or other publication is applicable to an order at the time the
order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind, expressed or
implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions
that such Cornell Dubilier company regards as typical for such applications, but are not intended
to constitute any guarantee, warranty or representation regarding any such matter – and Cornell
Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning
the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience
and capability to determine the correct products for their application. Any technical advice inferred
from this Information or otherwise provided by Cornell Dubilier with reference to the use of any
Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although
Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the
design and manufacturing of its products, in light of the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability
or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure
of an electrical component does not result in a risk of personal injury or property damage. Although
all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated in such warnings, cautions and notes, or that other
safety measures may not be required.