ADVANCE RELEASE
CS5467 Four-channel Power/Energy IC
Features
• Energy Data Linearity: ±0.1% of Reading over 1000:1 Dynamic Range • On-chip Functions:
- Instantaneous Voltage, Current, and Power - IRMS and VRMS, Active, Reactive, and Apparent Power - Current Fault and Voltage Sag Detect - System Calibrations / Phase Compensation - Temperature Sensor - Energy-to-pulse Conversion - Positive-only Accumulation Mode
Description
The CS5467 is an integrated power measurement device which combines four ∆Σ analog-to-digital converters, power calculation engine, energy-to-frequency converter, and a serial interface on a single chip. It is designed to accurately measure instantaneous current and voltage and calculate VRMS, IRMS, instantaneous power, active power, apparent power, and reactive power for high-performance power measurement applications. The CS5467 is optimized to interface to shunt resistors or current transformers for current measurement, and to resistive dividers or potential transformers for voltage measurement. The CS5467 also features system-level calibration, a temperature sensor, voltage sag & current fault detection, and phase compensation.
ORDERING INFORMATION:
See Page 45.
RESET VD+
• Meets Accuracy Spec for IEC, ANSI, & JIS • Low Power Consumption • GND-referenced Signals with Single Supply • On-chip, 2.5 V Reference • Power Supply Monitor • Simple Three-wire Digital Serial Interface • “Auto-boot” Mode from Serial E2PROM. • Power Supply Configurations
VA+ = +5 V; AGND = 0 V; VD+ = +3.3 V to +5 V
VA+
IIN1+ IIN1-
PGA
4th Order ∆Σ Modulator
Digital Filter
HPF Option
MODE CS SDI
VIN1+ VIIN1-
x10
2nd Order ∆Σ Modulator
Digital Filter
HPF Option Power Calculation Engine
Serial Interface
SDO SCLK INT E1 E2 E3
IIN2+ IIN2-
PGA
4th Order ∆Σ Modulator
Digital Filter
HPF Option
E-to-F
VIN2+ VIN2-
x10
2nd Order ∆Σ Modulator
Digital Filter
HPF Option
Calibration
VREFIN
x1 Voltage Reference AGND Power Monitor Temperature Sensor System Clock /K Clock Generator
VREFOUT
PFMON
XIN
XOUT CPUCLK
DGND
A dvance Product Information
http://www.cirrus.com
This document contains information for a new product. Cirrus Logic reserves the right to modify this product without notice.
Copyright © Cirrus Logic, Inc. 2006 (All Rights Reserved)
MAR ‘06 DS714A1
ADVANCE RELEASE
CS5467
TABLE OF CONTENTS
1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. Characteristics & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Analog Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Voltage Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Digital Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Switching Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4. Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.1 Digital Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.2 Voltage and Current Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4.3 Power Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4.4 Linearity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1 Analog Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1.1 Voltage Channel Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1.2 Current Channel Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.2 IIR Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.3 High-pass Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.4 Performing Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.5 Energy Pulse Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.5.1 Active Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.5.2 Apparent Energy Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.5.3 Reactive Energy Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.5.4 Voltage Channel Sign Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.5.5 PFMON Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.6 Sag and Fault Detect Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.7 On-chip Temperature Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.8 Voltage Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.9 System Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.10 Power-down States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.11 Oscillator Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.12 Event Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.12.1 Typical Interrupt Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.13 Serial Port Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.13.1 Serial Port Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.14 Register Paging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.15 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6. Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.1 Page 0 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.2 Page 1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
2 DS714A1
ADVANCE RELEASE
CS5467
38 39 39 39 39 39 39 40 40 40 41 41 41 41 42 42 42 42 43 44 45 45 46
6.3 Page 2 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7. System Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1 Channel Offset and Gain Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.1 Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.1.1 Duration of Calibration Sequence . . . . . . . . . . . . . . . . . . . . . 7.1.2 Offset Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.2.1 DC Offset Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . 7.1.2.2 AC Offset Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . 7.1.3 Gain Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.3.1 AC Gain Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . . 7.1.3.2 DC Gain Calibration Sequence . . . . . . . . . . . . . . . . . . . . . . . 7.1.4 Order of Calibration Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 Phase Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.3 Active Power Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8. Auto-boot Mode Using E2PROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1 Auto-boot Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Auto-boot Data for E2PROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.3 Which E2PROMs Can Be Used? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9. Basic Application Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. Package Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. Environmental, Manufacturing, & Handling Information . . . . . . . . . . . . . . . . . 13. Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DS714A1
3
ADVANCE RELEASE
CS5467
LIST OF FIGURES
Figure 1. CS5464 Read and Write Timing Diagrams ................................................................. 12 Figure 2. Timing Diagram for E1, E2, and E3 ...................................................................................... 13 Figure 3. Data Measurement Flow Diagram ............................................................................... 14 Figure 4. Data Measurement Flow Diagram ............................................................................... 14 Figure 5. Power Calculation Flow ............................................................................................... 15 Figure 6. Active and Reactive energy pulse outputs .................................................................. 19 Figure 7. Apparent energy pulse outputs.................................................................................... 19 Figure 8. Voltage Channel Sign Pulse outputs ........................................................................... 20 Figure 9. PFMON output to pin E3 ........................................................................................................ 20 Figure 10. Sag and Fault Detect................................................................................................. 20 Figure 11. Oscillator Connection ................................................................................................ 21 Figure 12. CS5467 Memory Map................................................................................................ 23 Figure 13. Calibration Data Flow ................................................................................................ 39 Figure 14. System Calibration of Offset...................................................................................... 39 Figure 15. System Calibration of Gain........................................................................................ 40 Figure 16. Example of AC Gain Calibration................................................................................ 40 Figure 17. Example of AC Gain Calibration................................................................................ 40 Figure 18. Typical Interface of E2PROM to CS5467 .................................................................. 42 Figure 19. Typical Connection Diagram (Single-phase, 3-wire – Direct Connect to Power Line) ...................... 43
LIST OF TABLES
Table 1. Current Channel PGA Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Table 2. E2 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table 3. E3 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table 4. Interrupt Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4
DS714A1
ADVANCE RELEASE
CS5467
1. OVERVIEW
The CS5467 is a CMOS monolithic power measurement device with a computation engine and an energy-to-frequency pulse output. The CS5467 combines four ∆Σ analog-to-digital converters (ADCs), system calibration, and a computation engine on a single chip. The CS5467 is designed for power measurement applications and is optimized to interface to a current-sense resistor or transformer for current measurement, and to a resistive divider or potential transformer for voltage measurement. The current channels provide programmable gains to accommodate various input levels from a multitude of sensing elements. With a single +5 V supply on VA+/AGND, the CS5467’s four input channels can accommodate common mode plus signal levels between (AGND - 0.25 V) and VA+. The CS5467 also is equipped with a computation engine that calculates instantaneous power, IRMS, VRMS, apparent power, active (real) power, reactive power, and power factor. Additional features of the CS5467 include line frequency monitoring, current and voltage sag detection, zero-cross detection, positive-only accumulation mode, and three programmable pulse output pins. To facilitate communication to a microprocessor, the CS5467 includes a simple three-wire serial interface which is SPI™ and Microwire™ compatible. The CS5467 provides three outputs for energy registration. Pins E1, E2, and E3 are designed to interface to a microprocessor.
DS714A1
5
ADVANCE RELEASE
CS5467
2. PIN DESCRIPTION
Crystal Out CPU Clock Output Positive Digital Supply Digital Ground Serial Clock Serial Data Ouput Chip Select Mode Select Differential Voltage Input Differential Voltage Input Voltage Reference Output Voltage Reference Input Differential Voltage Input Differential Voltage Input XOUT CPUCLK VD+ DGND SCLK SDO CS MODE VIN1+ VIN1VREFOUT VREFIN VIN2+ VIN21 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 XIN SDI E2 E1 INT RESET E3 PFMON IIN1+ IIN1VA+ AGND IIN2+ IIN2Crystal In Serial Data Input Energy Output 2 Energy Output 1 Interrupt Reset High-frequency Energy Output Power Fail Monitor Differential Current Input Differential Current Input Positive Analog Supply Analog Ground Differential Current Input Differential Current Input
Clock Generator Crystal Out Crystal In CPU Clock Output Control Pins and Serial Data I/O Serial Clock Input Serial Data Output Chip Select Mode Select Energy Output Reset Interrupt Serial Data Input Analog Inputs/Outputs Differential Voltage Inputs Differential Current Inputs Voltage Reference Output Voltage Reference Input Power Supply Connections Positive Digital Supply Digital Ground Positive Analog Supply Analog Ground Power Fail Monitor 3 4 18 17 21
VD+ - The positive digital supply. DGND - Digital Ground. VA+ - The positive analog supply. AGND - Analog ground. PFMON - The power fail monitor pin monitors the analog supply. If PFMON’s voltage threshold is tripped, a Low-Supply Detect (LSD) event is set in the status register.
1,28 2
XOUT, XIN - The output and input of an inverting amplifier. Oscillation occurs when connected to a crystal, providing an on-chip system clock. Alternatively, an external clock can be supplied to the XIN pin to provide the system clock for the device. CPUCLK - Output of on-chip oscillator which can drive one standard CMOS load.
5 6 7 8
SCLK - A Schmitt Trigger input pin. Clocks data from the SDI pin into the receive buffer and out of the transmit buffer onto the SDO pin when CS is low. SDO -Serial port data output pin.SDO is forced into a high impedance state when CS is high. CS - Low, activates the serial port interface. MODE - High, enables the “auto-boot” mode. The mode pin is pull-down by an internal resistor.
22, 25, E3, E1, E2 - Active low pulses with an output frequency proportional to energy. 26 23 24 27
RESET - A Schmitt Trigger input pin. Low activates Reset, all internal registers (some of which drive output pins) are set to their default states. INT - Low, indicates that an enabled event has occurred. SDI - Serial port data input pin. Data will be input at a rate determined by SCLK.
9,10 VIN1+, VIN1-, VIN2+, VIN2- - Differential analog input pins for the voltage channel. 13, 14 19,20, IIN+, IIN-, IIN2+, IIN2- - Differential analog input pins for the current channel. 15,16 11 12
VREFOUT - The on-chip voltage reference output. The voltage reference has a nominal magnitude of 2.5 V and is referenced to the AGND pin on the converter. VREFIN - The input to this pin establishes the voltage reference for the on-chip modulator.
6
DS714A1
ADVANCE RELEASE
CS5467
3. CHARACTERISTICS & SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
Parameter Positive Digital Power Supply Positive Analog Power Supply Voltage Reference Specified Temperature Range Symbol VD+ VA+ VREFIN TA Min 3.135 4.75 -40 Typ 5.0 5.0 2.5 Max 5.25 5.25 +85 Unit V V V °C
ANALOG CHARACTERISTICS
• • • • Min / Max characteristics and specifications are guaranteed over all Recommended Operating Conditions. Typical characteristics and specifications are measured at nominal supply voltages and TA = 25 °C. VA+ = VD+ = 5 V ±5%; AGND = DGND = 0 V; VREFIN = +2.5 V. All voltages with respect to 0 V. MCLK = 4.096 MHz.
Parameter Accuracy Active Power
(Note 1) All Gain Ranges Input Range 0.1% - 100% All Gain Ranges Input Range 0.1% - 100% All Gain Ranges Input Range 1.0% - 100% Input Range 0.1% - 1.0% All Gain Ranges Input Range 1.0% - 100% Input Range 0.1% - 1.0% All Gain Ranges Input Range 5% - 100%
Symbol PActive QAvg PF
Min
Typ
Max
Unit
80 -0.25 80 30 -
±0.1 ±0.2 ±0.2 ±0.27 ±0.1 ±0.17 ±0.1 500 100 94 -115 27 4.0 ±0.4
VA+ 22.5 4.5 -
% % % % % % % % dB V mVP-P mVP-P dB dB pF kΩ µVrms µVrms µV/°C %
Average Reactive Power
(Note 1 and 2)
Power Factor
(Note 1 and 2)
Current RMS
(Note 1)
IRMS VRMS CMRR
Voltage RMS
(Note 1)
Analog Inputs (All Channels) Common Mode Rejection Common Mode + Signal Analog Inputs (Current Channels) Differential Input Range
[(IIN+) - (IIN-)]
(DC, 50, 60 Hz)
(Gain = 10) (Gain = 50) (Gain = 50) (50, 60 Hz)
IIN THD IC EII
Total Harmonic Distortion Crosstalk with Voltage Channel at Full Scale Input Capacitance Effective Input Impedance Noise (Referred to Input) Offset Drift (Without the High Pass Filter) Gain Error
(Gain = 10) (Gain = 50)
NI OD GE
(Note 3)
Notes: 1. Applies when the HPF option is enabled. 2. Applies when the line frequency is equal to the product of the Output Word Rate (OWR) and the value of epsilon (ε).
DS714A1
7
ADVANCE RELEASE
CS5467
ANALOG CHARACTERISTICS (Continued)
Parameter Analog Inputs (Voltage Channel) Differential Input Range Symbol
[(VIN+) - (VIN-)]
Min 65 2 48 68 60 2.3 -
Typ 500 75 -70 2.0 16.0 ±3.0 ±5 1.3 2.9 1.7 33 20 7 10 55 75 65 2.45 2.55
Max 140 -
Unit mVP-P dB dB pF MΩ µVrms µV/°C % °C mA mA mA mW mW mW uW dB dB dB V V
VIN THD IC EII NV OD GE T
Total Harmonic Distortion Crosstalk with Current Channel at Full Scale (50, 60 Hz) Input Capacitance All Gain Ranges Effective Input Impedance Noise (Referred to Input) Offset Drift (Without the High Pass Filter) Gain Error Temperature Channel Temperature Accuracy Power Supplies Power Supply Currents (Active State)
(Note 3)
36 23 2.7
IA+
ID+ (VA+ = VD+ = 5 V) ID+ (VA+ = 5 V, VD+ = 3.3 V)
PSCA PSCD PSCD
Power Consumption
(Note 4)
Active State (VA+ = VD+ = 5 V) Active State (VA+ = 5 V, VD+ = 3.3 V) Stand-by State Sleep State
PC
Power Supply Rejection Ratio (50, 60 Hz)
(Note 5)
Voltage Channel Current Channel (Gain = 50x) Current Channel (Gain = 10x)
(Note 6) (Note 7)
PSRR PMLO PMHI
PFMON Low-voltage Trigger Threshold PFMON High-voltage Power-on Trip Point Notes: 3. Applies before system calibration.
4. All outputs unloaded. All inputs CMOS level. 5. Measurement method for PSRR: VREFIN tied to VREFOUT, VA+ = VD+ = 5 V, a 150 mV (zero-to-peak) (60 Hz) sinewave is imposed onto the +5 V DC supply voltage at VA+ and VD+ pins. The “+” and “-” input pins of both input channels are shorted to AGND. The CS5464 is then commanded to continuous conversion acquisition mode, and digital output data is collected for the channel under test. The (zero-to-peak) value of the digital sinusoidal output signal is determined, and this value is converted into the (zero-to-peak) value of the sinusoidal voltage (measured in mV) that would need to be applied at the channel’s inputs, in order to cause the same digital sinusoidal output. This voltage is then defined as Veq. PSRR is (in dB):
150 PSRR = 20 ⋅ log --------V eq
6. When voltage level on PFMON is sagging, and LSD bit = 0, the voltage at which LSD is set to 1. 7. If the LSD bit has been set to 1 (because PFMON voltage fell below PMLO), this is the voltage level on PFMON at which the LSD bit can be permanently reset back to 0.
8
DS714A1
ADVANCE RELEASE
CS5467
VOLTAGE REFERENCE
Parameter Reference Output Output Voltage Temperature Coefficient Load Regulation Reference Input Input Voltage Range Input Capacitance Input CVF Current VREFIN +2.4 +2.5 4 100 +2.6 V pF nA
(Note 8) (Note 9)
Symbol VREFOUT TCVREF ∆ VR
Min +2.4 -
Typ +2.5 25 6
Max +2.6 60 10
Unit V ppm/°C mV
Notes: 8. The voltage at VREFOUT is measured across the temperature range. From these measurements the following formula is used to calculate the VREFOUT Temperature Coefficient:.
TC VREF = V REFOUT ( (VREFOUT - UT VREFO
MAX AVG MIN )
(T
A
MAX
1 - T AM IN
( 1.0 x 10
6
9. Specified at maximum recommended output of 1 µA, source or sink.
DIGITAL CHARACTERISTICS
• • • • Min / Max characteristics and specifications are guaranteed over all Recommended Operating Conditions. Typical characteristics and specifications are measured at nominal supply voltages and TA = 25 °C. VA+ = VD+ = 5V ±5%; AGND = DGND = 0 V. All voltages with respect to 0 V. MCLK = 4.096 MHz.
Parameter Master Clock Characteristics Master Clock Frequency Master Clock Duty Cycle CPUCLK Duty Cycle Filter Characteristics Phase Compensation Range Input Sampling Rate Digital Filter Output Word Rate High-pass Filter Corner Frequency Channel-to-channel Time-shift Error Input/Output Characteristics High-level Input Voltage
All Pins Except XIN and SCLK and RESET XIN SCLK and RESET (Voltage Channel, 60 Hz) DCLK = MCLK/K (Both Channels) -3 dB (Note 12 and 13) Internal Gate Oscillator (Note 11)
Symbol MCLK
Min 2.5 40 40 -2.8 -
4.096 DCLK/8 DCLK/1024 0.5 1.0
OWR
25
Full-scale DC Calibration Range (Referred to Input) (Note 14) FSCR
(Note 15)
VIH
0.6 VD+ (VD+) - 0.5 0.8 VD+ -
Low-level Input Voltage (VD = 5 V)
All Pins Except XIN and SCLK and RESET XIN SCLK and RESET
VIL
DS714A1
(
Typ Max 20 60 60 +2.8 100 Unit MHz % % ° Hz Hz Hz %F.S. µs 0.8 1.5 0.2 VD+ V V V V V V 9
(
(
ADVANCE RELEASE
CS5467
Min Typ ±1 5 Max 0.48 0.3 0.2 VD+ 0.4 0.4 ±10 ±10 Unit V V V V V V µA µA pF
Parameter Low-level Input Voltage (VD = 3.3 V)
All Pins Except XIN and SCLK and RESET XIN SCLK and RESET
Symbol VIL VOH VOL Iin IOZ Cout
High-level Output Voltage Low-level Output Voltage
Iout = +5 mA Iout = -5 mA (VD = +5V) Iout = -2.5 mA (VD = +3.3V)
(VD+) - 1.0 -
Input Leakage Current 3-state Leakage Current Digital Output Pin Capacitance
(Note 16)
Notes: 10. All measurements performed under static conditions. 11. If a crystal is used, XIN frequency must remain between 2.5 MHz - 5.0 MHz. If an external oscillator is used, XIN frequency range is 2.5 MHz - 20 MHz, but K must be set so that MCLK is between 2.5 MHz - 5.0 MHz. 12. If external MCLK is used, the duty cycle must be between 45% and 55% to maintain this specification. 13. The frequency of CPUCLK is equal to MCLK. 14. The minimum FSCR is limited by the maximum allowed gain register value. The maximum FSCR is limited by the full-scale signal applied to the channel input. 15. Configuration Register bits PC[6:0] are set to “0000000”.
16. The MODE pin is pulled low by an internal resistor.
10
DS714A1
ADVANCE RELEASE
CS5467
SWITCHING CHARACTERISTICS
• • • • Min / Max characteristics and specifications are guaranteed over all Recommended Operating Conditions. Typical characteristics and specifications are measured at nominal supply voltages and TA = 25 °C. VA+ = 5 V ±5% VD+ = 3.3 V ±5% or 5 V ±5%; AGND = DGND = 0 V. All voltages with respect to 0 V. Logic Levels: Logic 0 = 0 V, Logic 1 = VD+.
Parameter Rise Times (Note 17) Fall Times (Note 17) Start-up Oscillator Start-up Time Serial Port Timing Serial Clock Frequency Serial Clock SDI Timing CS Falling to SCLK Rising Data Set-up Time Prior to SCLK Rising Data Hold Time After SCLK Rising SDO Timing CS Falling to SDO Driving SCLK Falling to New Data Bit (hold time) CS Rising to SDO Hi-Z Auto-Boot Timing Serial Clock MODE setup time to RESET Rising RESET rising to CS falling CS falling to SCLK rising SCLK falling to CS rising CS rising to driving MODE low (to end auto-boot sequence) SDO guaranteed setup time to SCLK rising
Pulse Width Low Pulse Width High Pulse Width High Pulse Width Low XTAL = 4.096 MHz (Note 18) Any Digital Output
Symbol trise tfall
Any Digital Output
Min 200 200
Typ 50 50 60 -
Max 1.0 1.0 2 -
Unit µs ns µs ns ms MHz ns ns
tost SCLK t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 t15 t16
50 50 100 -
20 20 20 8 8
50 50 50
ns ns ns ns ns ns MCLK MCLK ns MCLK
50 48 100 8 16 50 100
MCLK MCLK ns ns
Notes: 17. Specified using 10% and 90% points on waveform of interest. Output loaded with 50 pF. 18. Oscillator start-up time varies with crystal parameters. This specification does not apply when using an external clock source.
DS714A1
11
ADVANCE RELEASE
CS5467
t3
CS
t1 t2
SC LK
t4 MSB-1 MSB-1 MSB MSB LSB t5 MSB-1 MSB-1 MSB MSB LSB LSB LSB L o w B y te
SDI
C o m m a n d T im e 8 S C L K s
H ig h B y te
M id B y te
SDI Write Timing (Not to Scale)
CS
t6 MSB-1 MSB H igh B yte MSB-1 MSB LSB M id B yte MSB-1 MSB LSB Low B yte LSB
t15 t14 t7 STOP bit Last 8 B it s
t8
SDO
UNKNOW N t1 t2
t7
SCLK
MSB-1
MSB
SDI
C om m and T im e 8 S C LK s
LSB
S Y N C 0 or S Y N C 1 C om m and
S Y N C 0 or S Y N C 1 C om m and
S Y N C 0 or S Y N C 1 C om m and
SDO Read Timing (Not to Scale)
t11
MODE
( IN P U T )
RESET
( IN P U T )
t12 t13
CS
(O U T P U T )
SCLK
(O U T P U T )
t10
t16
t9 t4 t5
SDO
(O U T P U T )
SDI
( IN P U T )
D a ta fro m E E P R O M
Auto-boot Sequence Timing (Not to Scale)
Figure 1. CS5464 Read and Write Timing Diagrams 12 DS714A1
ADVANCE RELEASE
CS5467
SWITCHING CHARACTERISTICS (Continued)
Parameter E1, E2, and E3 Timing Period Pulse Width Rising Edge to Falling Edge E2 Setup to E1 and/or E3 Falling Edge E1 Falling Edge to E3 Falling Edge
(Note 19 and 20)
Symbol tperiod tpw t3 t4 t5
Min 250 244 6 1.5 248
Typ -
Max -
Unit µs µs µs µs µs
Notes: 19. Pulse output timing is specified at MCLK = 4.096 MHz, E2MODE = 0, and E3MODE[1:0] = 0. Refer to 5.5 Energy Pulse Output on page 18 for more information on pulse output pins. 20. Timing is proportional to the frequency of MCLK.
tpw
E1 E2
tperiod t3 t4 tpw t5 tperiod t3 t5
t4
E3
Figure 2. Timing Diagram for E1, E2, and E3
ABSOLUTE MAXIMUM RATINGS
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation is not guaranteed at these extremes. Parameter DC Power Supplies
(Notes 21 and 22) Positive Digital Positive Analog (Notes 23, 24, 25)
Symbol VD+ VA+ IIN IOUT
(Note 26) All Analog Pins All Digital Pins
Min -0.3 -0.3 - 0.3 -0.3 -40 -65
Typ -
Max +6.0 +6.0 ±10 100 500 (VA+) + 0.3 (VD+) + 0.3 85 150
Unit V V mA mA mW V V °C °C
Input Current, Any Pin Except Supplies Output Current, Any Pin Except VREFOUT Power Dissipation Analog Input Voltage Digital Input Voltage Ambient Operating Temperature Storage Temperature
PD VINA VIND TA Tstg
Notes: 21. VA+ and AGND must satisfy [(VA+) - (AGND)] ≤ + 6.0 V. 22. VD+ and AGND must satisfy [(VD+) - (AGND)] ≤ + 6.0 V. 23. Applies to all pins including continuous over-voltage conditions at the analog input pins. 24. Transient current of up to 100 mA will not cause SCR latch-up. 25. Maximum DC input current for a power supply pin is ±50 mA. 26. Total power dissipation, including all input currents and output currents. DS714A1 13
ADVANCE RELEASE
CS5467
VDCoff Vgn
VOLTAGE
x10
2nd Order ∆Σ Modulator
SINC 3 Digital Filter
X
IIR
DELAY REG
+
+
MUX
APF HPF HPF
Σ
V VQ
X
SYSGain
IIR
X
X
Q
Control Register PC[7] PC[6] PC[5] PC[4] PC[3] PC[2] PC[1] PC[0]
2322
ε
...
VHPF
6
X
IHPF
5
...
321 0
Operational Modes Register
7
2π
X
P
MUX
CURRENT
PGA
4th Order ∆Σ Modulator
DELAY REG
SINC 3
X
IIR
+
Σ
+
X I gn
HPF APF
I
REGISTER NAMES INDICATED IN SHADED AREAS.
Digital Filter
SYSGain
IDCoff
Figure 3. Data Measurement Flow Diagram
4. THEORY OF OPERATION
The CS5467 is a four-channel analog-to-digital converter (ADC) followed by a computation engine that performs power calculations and energy-to-pulse conversion. The data flow for the voltage and current channel measurement and the power calculation algorithms are depicted in Figures 3, 4, and 5. The CS5467 analog inputs are structured with two Current channels and two Voltage channels, and are optimized to simplify interfacing to various sensing elements. As shown in Figures 3 and 4, the current and voltage channels are fully independent. The voltage-sensing elements introduces a voltage waveform on the two voltage channel inputs VIN± and VIN2±, which is subject to a gain of 10x. A second-order delta-sigma modulator samples the amplified signal for digitization. Simultaneously, the current-sensing elements introduce a voltage waveform on the two current channel inputs IIN± and IIN2±, which is subject to the two selectable gains of the programmable gain amplifier (PGA). The amplified signals are sampled by a fourth-order delta-sigma modulator for digitization. The converters sample at a rate of MCLK/8. The over-sampling provides a wide dynamic range and simplified anti-alias filter design.
4.1 Digital Filters
The decimating digital filters on the four channels are Sinc3 filters followed by 3rd-order IIR filters. The single-bit data is passed to the low-pass decimation filter and output at a fixed word rate. The output word is passed to an IIR filter to compensate for the magnitude roll off of the low-pass filtering operation. An optional digital high-pass filter (HPF in Figures 3 and 4) removes any DC component from the selected signal path. By removing the DC component from the voltage and/or the current channel, any DC content will also be removed from the calculated active power as well. With both HPFs enabled the DC component will be removed
V2 dcoff
V2gn X
VOLTAGE 2
X10
2nd Order ∆Σ Modulator
SINC 3 Digital Filter
X
IIR
DELAY REG
+
+
MUX
APF HPF HPF
Σ
V2 V2Q
SYSGain
IIR
X
X
Q2
ε
Control Register PC[7] PC[6] PC[5] PC[4] PC[3] PC[2] PC[1] PC[0]
2322
X
...
VHPF
8
IHPF
7
...
321 0
π
X
P2
Operational Modes Register
7
MUX
CURRENT 2
PGA
4th Order ∆Σ Modulator
DELAY REG
SINC 3
X
IIR
+
Σ
+
X
HPF APF
I2 REGISTER NAMES INDICATED IN SHADED AREAS.
Digital Filter
SYSGain
I2 dcoff
I2gn
Figure 4. Data Measurement Flow Diagram
14
DS714A1
ADVANCE RELEASE
CS5467
Vacoff (V2acoff)
V (V2) X
Σ
N
÷N
√ √
÷N ÷N
+
+
Σ
X
VRMS (V2RMS)
S (S2) X
Iacoff (I2acoff)
+ +
+
Σ
-
√
Energy-to-pulse
QTRIG (Q2TRIG)
I (I2)
X
Σ
N X
÷N
Σ
IRMS (I2RMS)
Inverse
X
PF (PF2) E1 E2 E3
Poff (P2off)
PulseRateE
+
P (P2)
+
Σ
Q (Q2)
Σ Σ
N N
PACTIVE (P2ACTIVE) X QAVG (Q2AVG) REGISTER NAMES (CHANNEL 2 REGISTER NAMES) INDICATED IN SHADED AREAS.
Figure 5. Power Calculation Flow
from the calculated VRMS and I RMS, as well as the apparent power. When the optional HPF in either channel is disabled, an all-pass filter (APF) in the complementary channel is implemented. The APF has an amplitude response that is flat within the channel bandwidth and is used for matching phase in systems where only one channel’s HPF is engaged.
4.3 Power Measurements
The instantaneous voltage and current samples are multiplied to obtain the instantaneous power (see Figure 3 and 4). The product is then averaged over N conversions to compute active power. The average active power measured on channels 1 and 2 is used to drive energy pulse output E1. Energy output E2 is configurable and can provide an energy sign or a pulse output that is proportional to the average apparent power measured on channels 1 and 2. Energy output E3 provides a pulse output that is proportional to the average reactive power or the average apparent power measured on channels 1 and 2. Output E3 can also be set to indicate the PFMON comparator output or to indicate the sign of the voltage applied to the voltage channel. The apparent power (S, S2) is the combination of the active power and reactive power, without reference to an impedance phase angle, and is calculated by the CS5467 using the following formula:
S = V RMS × I RMS
4.2 Voltage and Current Measurements
The digital filter output word is subject to a DC-offset adjustment and a gain calibration (See Section 7. System Calibration on page 39). The calibrated measurement is available by reading the instantaneous voltage and current registers. The Root Mean Square (RMS in Figure 5) calculations are performed on N instantaneous voltage and current samples, Vn and In, respectively (where N is the cycle count), using the formula:
I RMS =
∑ In n=0 -------------------N
N–1
Power Factor (PF, PF2) is the active power (PActive, P2Active) divided by the apparent power (S, S2)
P Active PF = ----------------S
The sign of the power factor is determined by the active power. and likewise for VRMS, using Vn. IRMS and VRMS are accessible by register reads, which are updated once every cycle count (referred to as a computational cycle).
DS714A1
15
ADVANCE RELEASE
CS5467
The CS5467 calculates the reactive power (QTrig, Q2Trig) utilizing trigonometric identities, using the formula
N
Q Trig =
2 S 2 – P Active
The average reactive power calculation (QAvg, Q2Avg) is generated by averaging the voltage and multiplying that value by the current measurement with a 90° phase difference between the two. The 90° phase shift is realized by applying an IIR digital filter in the voltage channel to obtain quadrature voltage (see Figure 3 and 4). This filter will give exactly -90° phase shift across all frequencies, and utilizes epsilon (ε) to achieve unity gain at the line frequency. The instantaneous quadrature voltage (VQ, V2Q) and current (I, I2) samples are multiplied to obtain the instantaneous quadrature power (Q, Q2). The product is then averaged over N conversions, utilizing the formula
∑ Qn n=1 Q Avg = -----------------------N
The peak current (Ipeak, I2peak) and peak voltage (Vpeak, V2peak) are the instantaneous current and voltage, respectively, with the greatest magnitude detected during the previous computation cycle. Active, apparent, reactive, and fundamental power are updated every computation cycle.
4.4 Linearity Performance
The linearity of the VRMS, I RMS, active, reactive, and power-factor power measurements (before calibration) will be within ±0.1% of reading over the ranges specified, with respect to the input voltage levels required to cause full-scale readings in the IRMS and VRMS registers. Refer to Accuracy Specifications on page 7. Until the CS5467 is calibrated, the accuracy of the CS5467 (with respect to a reference line-voltage and line-current level on the power mains) is not guaranteed
16
DS714A1
ADVANCE RELEASE
CS5467
5. FUNCTIONAL DESCRIPTION
5.1 Analog Inputs
The CS5467 is equipped with four fully differential input channels. The inputs VIN±, VIN2±, IIN±, and IIN2± are designated as the voltage, voltage 2, current, and current 2 channel inputs, respectively. The full-scale differential input voltage for the current and voltage channel is ±250 mVP. The Current Gain Register also facilitates an additional programmable gain of up to 4x. If an additional gain is applied to the voltage and/or current channel, the maximum input range should be adjusted accordingly.
5.2 IIR Filters
The current and voltage channels are equipped with a 3rd-order IIR filter, that is used to compensate for the magnitude roll off of the low-pass decimation filter.
5.1.1 Voltage Channel Input
The output of the line voltage resistive divider or transformer is connected to the VIN+ (VIN2+) and VIN(VIN2-) input pins of the CS5467. The voltage channels are equipped with a 10x fixed-gain amplifier. The full-scale signal level that can be applied to the voltage channel is ±250 mV. If the input signal is a sine wave, the maximum RMS voltage at a gain 10x is:
250mV P 2
5.3 High-pass Filters
By removing the offset from either channel, no error component will be generated at DC when computing the active power. By removing the offset from both channels, no error component will be generated at DC when computing VRMS, IRMS, and apparent power. Operational Mode Register bits VHPF, VHPF2, IHPF and IHPF2 activate the HPF in the voltage and current channel, respectively. When a high-pass filter is active in only one channel, an all-pass filter (APF) is applied to the companion channel. The APF has an amplitude response that is flat within the channel bandwidth and is used for matching phase in systems where only one HPF is engaged.
-------------------- ≅ 176.78mV -
RMS
which is approximately 70.7% of maximum peak voltage. The voltage channel is also equipped with a Voltage Gain Register, allowing for an additional programmable gain of up to 4x.
5.1.2 Current Channel Inputs
The output of the current-sense resistor or transformer is connected to the IIN+ (IIN2+) and IIN- (IIN2-) input pins of the CS5467. To accommodate different current-sensing elements, the current channel incorporates a programmable gain amplifier (PGA) with two programmable input gains. Configuration Register bit Igain (I2gain) defines the two gain selections and corresponding maximum input signal level.
Igain, I2gain Maximum Input Gain
5.4 Performing Measurements
The CS5467 performs measurements of instantaneous voltage (Vn) and current (In), and calculates instantaneous power (Pn) at an output word rate (OWR) of
( MCLK ⁄ K ) OWR = ---------------------------1024
0 1
±250 mV ±50 mV
10x 50x
where K is the value of the clock divider selected in the Configuration Register by bits K[3:0]. Note that a value of K[3:0] = 0000 results in a clock divider setting of 16, rather than zero. The RMS voltage (VRMS, V2RMS), RMS current (IRMS, I2RMS), and active power (Pactive, P2active) are computed using N instantaneous samples of Vn, In, and Pn respectively, where N is the value in the Cycle Count Register and is referred to as a “computation cycle”. The apparent power (S, S2) is the product of VRMS and IRMS. A computation cycle is derived from the master clock (MCLK), with frequency: Under default conditions and
OWR Computation Cycle = -------------N
Table 1. Current Channel PGA Setting
For example, if Igain=0 (I2gain=0), current channel 1(2) PGA gain is set to 10x. If the input signals are pure sinusoids with zero phase shift, the maximum peak differential signal on the current or voltage channel is ±250 mVP. The input signal levels are approximately 70.7% of maximum peak voltage and produce a full-scale energy pulse registration equal to 50% of absolute maximum energy registration. This will be discussed further in See Section 5.5 Energy Pulse Output on page 18.
with K = 1, N = 4000, and MCLK = 4.096 MHz – the OWR = 4000 and the Computation Cycle = 1 Hz.
DS714A1
17
ADVANCE RELEASE
CS5467
All measurements are available as a percentage of full scale. The format for signed registers is a two’s complement, normalized value between -1 and +1. The format for unsigned registers is a normalized value between 0 and 1. A register value of
23 (2 – 1) ----------------------- = 0.99999988 23 2
The E1 pulse output is designed to indicate the average active energy measured on channels 1 and 2. The E2 pin can be used to register average apparent energy measured on channels 1 and 2 or to indicate the sign of energy. Table 2 defines the pulse output mode, which is controlled by bit E2MODE in the Operational Mode Register.
E2MODE E2 Output Mode
represents the maximum possible value. At each instantaneous measurement, the CRDY bit will be set in the Status Register, and the INT pin will become active if the CRDY bit is unmasked in the Mask Register. At the end of each computation cycle, the DRDY bit will be set in the Status Register, and the INT pin will become active if the DRDY bit is unmasked in the Mask Register. When these bits are asserted, they must be cleared before they can be asserted again. If the Cycle Count Register (N) is set to 1, all output calculations are instantaneous, and DRDY, like CRDY, will indicate when instantaneous measurements are finished. Some calculations are inhibited when the cycle count is less than 2. Epsilon (ε) is the ratio of the input line frequency (fi) to the sample frequency (fs) of the ADC.
0 1
Sign of Energy Apparent Energy
Table 2. E2 Pin Configuration
The E3 pin can be set to register average reactive energy measured on channels 1 and 2 (default), PFMON, voltage channel sign, or average apparent energy measured on channels 1 and 2. Table 3 defines the pulse output format, which is controlled by bits E3MODE[1:0] in the Operational Mode Register.
E3MODE1 E3MODE0 E3 OutPut Mode
0 0 1 1
0 1 0 1
Reactive Energy PFMON Voltage Channel Sign Apparent Energy
ε
Table 3. E3 Pin Configuration
= fi ⁄ fs
where fs = MCLK / (K x 1024). With MCLK = 4.096 MHz and clock divider K = 1, fs = 4000 Hz. For the two most-common line frequencies, 50 Hz and 60 Hz
ε
and
= 50 Hz ⁄ 4000 Hz = 0.0125
The pulse output frequencies of E1, E2, and E3 are directly proportional to the power calculated from the input signals. The value contained in the PulseRateE Register is the ratio of the frequency of energy-output pulses to the number of samples, at full scale, which defines the average frequency for the output pulses. The pulse width, tpw in Figure 2, is an integer multiple of MCLK cycles approximately equal to:
t pw ( sec )
ε
= 60 Hz ⁄ 4000 Hz = 0.015
-----------------------------------≅ ( MCLK/K ) / 1024
1
respectively. Epsilon is used to set the gain of the 90° phase shift (IIR) filter for the average reactive power calculation.
If MCLK = 4.096 MHz and K = 1 then tpw ≅ 0.25 ms.
5.5.1 Active Energy
The E1 pin produces active-low pulses with an output frequency proportional to the average active power measured on channels 1 and 2. The E2 pin is the energy direction indicator. Positive energy is represented by E1 pin falling while the E2 is high. Negative energy is represented by the E1 pin falling while the E2 is low. The E1 and E2 switching characteristics are specified in Figure 2. Timing Diagram for E1, E2, and E3 on page 13.
5.5 Energy Pulse Output
The CS5467 provides three output pins for energy registration. By default, E1 is used to register average active energy measured on channels 1 and 2, E3 is used to register average reactive energy measured on channels 1 and 2, and E2 indicates the sign of both active and reactive energy. (See Figure 2. Timing Diagram for E1, E2, and E3 on page 13.)
18
DS714A1
ADVANCE RELEASE
CS5467
Figure 6 illustrates the pulse output format with positive active energy and negative reactive energy.
where
E1 E2 E3
FREQ
S
= [ ( S + S2 ) ⁄ 2 ] × PulseRate
Figure 6. Active and Reactive energy pulse outputs
The pulse output frequency of E1 is directly proportional to the active power calculated from the input signals. To calculate the output frequency of E1, the following transfer function can be utilized:
FREQ P = [ ( P Active + P2 Active ) ⁄ 2 ] × PulseRate where P ( 2 ) Active VIN ( 2 ) × V ( 2 ) gain × IIN ( 2 ) × I ( 2 ) gain × PF ( 2 ) ----------------------------------------------------------------------------------------------------------------------------------2 VREFIN
VIN ( 2 ) × V ( 2 ) gain × IIN ( 2 ) × I ( 2 ) gain ---------------------------------------------------------------------------------------------------------2 VREFIN FREQS = Average frequency of apparent energy E2 and/or E3 pulses [Hz] VIN(2) = rms voltage across VIN(2)+ and VIN(2)- [V] V(2)gain = Voltage channel gain IIN(2) = rms voltage across IIN(2)+ and IIN(2)- [V] I(2)gain = Current channel gain PulseRate = PulseRateE x (MCLK/K)/2048 [Hz] VREFIN = Voltage at VREFIN pin [V] S(2)
=
=
FREQP = Average frequency of active energy E1 pulses [Hz] VIN(2) = rms voltage across VIN(2)+ and VIN(2)- [V] V(2)gain = Voltage channel gain IIN(2) = rms voltage across IIN(2)+ and IIN(2)- [V] I(2)gain = Current channel gain PF(2) = Power Factor PulseRate = PulseRateE x (MCLK/K)/2048 [Hz] VREFIN = Voltage at VREFIN pin [V]
With MCLK = 4.096 MHz and default settings, the pulses will have an average frequency equal to the frequency specified by PulseRateE when the input signals applied to the voltage and current channels cause full-scale readings in the instantaneous voltage and current registers. The maximum pulse frequency from the E2 (and/or E3) pin is (MCLK/K)/2048. The E2 (and/or E3) pin outputs apparent energy, but has no energy direction indicator.
5.5.3 Reactive Energy Mode
Reactive energy pulses are output on pin E3 by setting bit E3MODE[1:0] = 0 (default) in the Operational Mode Register. Positive reactive energy is registered by E3 falling when E2 is high. Negative reactive energy is registered by E3 falling when E2 is low. Figure 6 on page 19 illustrates the pulse output format with negative reactive energy output on pin E3 and the sign of the energy on E2. The E3 and E2 pulse output switching characteristics are specified in Figure 2 on page 13. The pulse output frequency of E3 is directly proportional to the reactive power calculated from the input signals. To calculate the output frequency on E3, the following transfer function can be utilized:
FREQ Q = [ ( Q Avg + Q2 Avg ) ⁄ 2 ] × PulseRate where Q ( 2 ) Avg VIN ( 2 ) × V ( 2 ) gain × IIN ( 2 ) × I ( 2 ) gain × PQ ( 2 ) -----------------------------------------------------------------------------------------------------------------------------------2 VREFIN
With MCLK = 4.096 MHz, PF = 1, and default settings, the pulses will have an average frequency equal to the frequency specified by PulseRateE when the input signals applied to the voltage and current channels cause full-scale readings in the instantaneous voltage and current registers. The maximum pulse frequency from the E1 pin is (MCLK/K)/2048.
5.5.2 Apparent Energy Mode
Pin E2 outputs apparent energy pulses when the Operational Mode Register bit E2MODE = 1. Pin E3 outputs apparent energy pulses when the Operational Mode Register bits E3MODE[1:0] = 3 (11b). Figure 7 illustrates the pulse output format with apparent energy on E2 (E2MODE = 1 and E3MODE[1:0] = 0)
E1 E2 E3
=
Figure 7. Apparent energy pulse outputs
FREQQ = Average frequency of reactive energy E3 pulses [Hz] VIN(2) = rms voltage across VIN(2)+ and VIN(2)- [V] V(2)gain = Voltage channel gain IIN(2) = rms voltage across IIN(2)+ and IIN(2)- [V] I(2)gain = Current channel gain PQ = 1 – PF2 PulseRate = PulseRateE x (MCLK/K)/2048 [Hz] VREFIN = Voltage at VREFIN pin [V]
The pulse output frequency of E2 (and/or E3) is directly proportional to the apparent power calculated from the input signals. Since apparent power is without reference to an impedance phase angle, the following transfer function can be utilized to calculate the output frequency on E2 (and/or E3).
With MCLK = 4.096 MHz, PF = 0 and default settings, the pulses will have an average frequency equal to the frequency specified by PulseRateE when the input signals applied to the voltage and current channels cause full-scale readings in the instantaneous voltage and cur19
DS714A1
ADVANCE RELEASE
CS5467
rent registers. The maximum pulse frequency from the E1 pin is (MCLK/K)/2048.
rent, respectively. Voltage and current sag duration is specified in terms of ADC cycles.
5.5.4 Voltage Channel Sign Mode
Setting bits E3MODE[1:0] = 2 (10b) in the Operational Mode Register outputs the sign of the voltage channel on pin E3. Figure 8 illustrates the output format with voltage channel sign on E3
E1 E2 E3
Level
Figure 8. Voltage Channel Sign Pulse outputs
Output pin E3 is high when the line voltage is positive and pin E3 is low when the line voltage is negative.
Duration
5.5.5 PFMON Output Mode
Setting bit E3MODE[1:0] = 1 (01b) in the Operational Mode Register outputs the state of the PFMON comparator on pin E3. Figure 9 illustrates the output format with PFMON on E3
E1 E2 E3 Above PFMON Threshold Below PFMON Threshold
Figure 10. Sag and Fault Detect
5.7 On-chip Temperature Sensor
The on-chip temperature sensor is designed to assist in characterizing the measurement element over a desired temperature range. Once a temperature characterization is performed, the temperature sensor can be utilized to assist in compensating for temperature drift. Temperature measurements are performed when a one is written to the Temperature Measurement (Tmeas) register and stored in the Temperature Register. The Temperature Register (T) default is Celsius scale (°C). The Temperature Gain Register (Tgain) and Temperature Offset Register (Toff) are constant values allowing for temperature scale conversions. The temperature update rate is a function of the number of ADC samples. With MCLK = 4.096 MHz and K = 1 the update rate is:
2240 samples --------------------------------------- = ( MCLK ⁄ K ) ⁄ 1024 0.56 sec
Figure 9. PFMON output to pin E3
When PFMON is greater than the threshold, pin E3 is high and when PFMON is less than the threshold pin E3 is low.
5.6 Sag and Fault Detect Feature
Status bit VSAG (V2SAG) and IFAULT (I2FAULT) in the Status Register, indicates a sag occurred in the power line voltage (voltage 2) and current (current 2), respectively. For a sag condition to be identified, the absolute value of the instantaneous voltage or current must be less than the sag level for more than half of the sag duration (see Figure 10). To activate voltage sag detection, a voltage sag level must be specified in the Voltage Sag Level Register (VSAGlevel, V2SAGlevel), and a voltage sag duration must be specified in the Voltage Sag Duration Register (VSAGduration, V2SAGduration). To activate current fault detection, a current sag level must be specified in the Current Fault Level Register (ISAGlevel, I2SAGlevel), and a current sag duration must be specified in the Current Fault Duration Register (ISAGduration, I2SAGduration). The voltage and current sag levels are specified as the average of the absolute instantaneous voltage and cur-
The Cycle Count Register (N) must be set to a value greater than one. Status bit TUP in the Status Register, indicates when the Temperature Register is updated. The Temperature Offset Register sets the zero-degree measurement. To improve temperature measurement accuracy, the zero-degree offset may need to be adjusted after the CS5467 is initialized. Temperature-offset calibration is achieved by adjusting the Temperature Offset Register (Toff) by the differential temperature (∆T) measured from a calibrated digital thermometer and the CS5467 temperature sensor. A one-degree adjustment to the Temperature Register (T) is achieved by
20
DS714A1
ADVANCE RELEASE
CS5467
adding 2.737649x10-4 to the Temperature Offset Register (Toff). Therefore,
T off
5.10 Power-down States
The CS5467 has two power-down states, Stand-by and Sleep. In the stand-by state all circuitry except the voltage reference and crystal oscillator is turned off. To return the device to the active state, a power-up command is sent to the device. In Sleep state, all circuitry except the instruction decoder is turned off. When the power-up command is sent to the device, a system initialization is performed (See Section 5.9 System Initialization on page 21).
=
T
+ ( ∆ T × 2.737649 ⋅ 10 – 4 ) off
if Toff = -0.094488 and ∆T = -2.0 (°C), then
T off
= ( – 0.094488 + ( – 2.0 × 2.737649 ⋅ 10 ) ) =
–4
– 0.09504
or 0xF3D5BB (2’s compliment notation) is stored in the Temperature Offset Register (Toff). To convert the Temperature Register (T) from a Celsius scale (°C) to a Fahrenheit scale (°F) utilize the formula
o
5.11 Oscillator Characteristics
XIN and XOUT are the input and output of an inverting amplifier configured as an on-chip oscillator, as shown in Figure 11. The oscillator circuit is designed to work with a quartz crystal. To reduce circuit cost, two load capacitors C1 and C2 are integrated in the device, from XIN to DGND, and XOUT to DGND. PCB trace lengths should be minimized to reduce stray capacitance. To drive the device from an external clock source, XOUT should be left unconnected while XIN is driven by the external circuitry. There is an amplifier between XIN and the digital section which provides CMOS level signals. This amplifier works with sinusoidal inputs so there are no problems with slow edge times. The CS5467 can be driven by an external oscillator ranging from 2.5 to 20 MHz, but the K divider value must be set such that the internal MCLK will run somewhere between 2.5 MHz and 5 MHz. The K divider value is set with the K[3:0] bits in the Configuration Register. As an example, if XIN = MCLK = 15 MHz, and K is set to 5, DCLK will equal 3 MHz, which is a valid value for DCLK.
9o F = -- ( C + 17.7778 ) 5
Applying the above relationship to the CS5461A temperature measurement algorithm
–4 o o 9 T 〈 F〉 = ⎛ -- × T gain ⎞ T 〈 C〉 + ⎛ T off + ( 17.7778 × 2.737649 ⋅ 10 )⎞ ⎝5 ⎠ ⎝ ⎠
If Toff = -0.09504 and Tgain = 26.443 for a Celsius scale, the modified values are Toff = -0.09017 (0xF47550) and Tgain = 47.6 (0x5F3333) for a Fahrenheit scale.
5.8 Voltage Reference
The CS5467 is specified for operation with a +2.5 V reference between the VREFIN and AGND pins. To utilize the on-chip 2.5 V reference, connect the VREFOUT pin to the VREFIN pin of the device. The VREFIN can be used to connect external filtering and/or references.
5.9 System Initialization
Upon powering up, the digital circuitry is held in reset until the analog voltage reaches 4.0 V. At that time, an eight-XIN-clock-period delay is enabled to allow the oscillator to stabilize. The CS5467 will then initialize. A hardware reset is initiated when the RESET pin is asserted with a minimum pulse width of 50 ns. The RESET signal is asynchronous, with a Schmitt-trigger input. Once the RESET pin is de-asserted, an eight-XIN-clock-period delay is enabled. A software reset is initiated by writing the command 0x80. After a hardware or software reset, the internal registers (some of which drive output pins) will be reset to their default values. Status bit DRDY in the Status Register, indicates the CS5467 is in its active state and ready to receive commands.
5.12 Event Handler
The INT pin is used to indicate that an internal error or event has taken place in the CS5467. Writing a logic 1
XOUT C1
Oscillator Circuit
XIN C2
DGND
C1 = C2 = 22 pF
Figure 11. Oscillator Connection
DS714A1
21
ADVANCE RELEASE
CS5467
to any bit in the Mask Register allows the corresponding bit in the Status Register to activate the INT pin. The interrupt condition is cleared by writing a logic 1 to the bit that has been set in the Status Register. The behavior of the INT pin is controlled by the IMODE and IINV bits of the Configuration Register.
IMODE IINV INT Pin
INTERRUPT HANDLER ROUTINE:
4) Read the Status Register. 5) Disable all interrupts. 6) Branch to the proper interrupt service routine. 7) Clear the Status Register by writing back the read value in step 4. 8) Re-enable interrupt 9) Return from interrupt service routine. This handshaking procedure ensures that any new interrupts activated between steps 4 and 7 are not lost (cleared) by step 7.
0 0 1 1
0 1 0 1
Active-low Level Active-high Level Low Pulse High Pulse
5.13 Serial Port Overview
Table 4. Interrupt Configuration
If the interrupt output signal format is set for either falling or rising edge, the duration of the INT pulse will be at least one DCLK cycle (DCLK = MCLK/K).
The CS5467 incorporates a serial port transmit and receive buffer with a command decoder that interprets one-byte (8-bit) commands as they are received. There are four types of commands: instructions, synchronizing, register writes, and register reads (See Section 5.15 Commands on page 24). Instructions are one byte in length and will interrupt any instruction currently executing. Instructions do not affect register reads currently being transmitted. Synchronizing commands are one byte in length and only affect the serial interface. Synchronizing commands do not affect operations currently in progress. Register writes must be followed by three bytes of data. Register reads can return up to four bytes of data. Commands and data are transferred most-significant bit (MSB) first. Figure 1 on page 12, defines the serial port timing and required sequence necessary for writing to and reading from the serial port receive and transmit buffer, respectively. While reading data from the serial port, commands and data can be written simultaneously. Starting a new register read command while data is being read will terminate the current read in progress. This is acceptable if the remainder of the current read data is not needed. During data reads, the serial port requires input data. If a new command and data is not sent, SYNC0 or SYNC1 must be sent.
5.12.1 Typical Interrupt Handler
The steps below show how interrupts can be handled.
INITIALIZATION:
1) All Status bits are cleared by writing 0xFFFFFF to the Status Register. 2) The condition bits which will be used to generate interrupts are set to logic 1 in the Mask Register. 3) Enable interrupts.
5.13.1 Serial Port Interface
The serial port interface is a “4-wire” synchronous serial communications interface. The interface is enabled to start excepting SCLKs when CS (Chip Select) is asserted (logic 0). SCLK (Serial bit-clock) is a Schmitt-trigger input that is used to strobe the data on SDI (Serial Data In) into the receive buffer and out of the transmit buffer onto SDO (Serial Data Out).
22
DS714A1
ADVANCE RELEASE
CS5467
If the serial port interface becomes unsynchronized with respect to the SCLK input, any attempt to clock valid commands into the serial interface may result in unexpected operation. Therefor, the serial port interface must be re-initialized by one of the following actions: Drive the CS pin high, then low. Hardware Reset (drive RESET pin low for at least 10 µs). Issue the Serial Port Initialization Sequence, which is 3 (or more) SYNC1 command bytes (0xFF) followed by one SYNC0 command byte (0xFE).
registers in another page, the Page Register (address 0x1F) must be written with the desired page number.
0xFFF
ROM 2048 Words
Pages 0x40 - 0x7F
0x800 0x7FF Hardware Registers* 32 Pages 0x400 0x3FF Software Register* 32 Pages 0x000 * Accessed using register read/write commands. Pages 0 - 0x1F Pages 0x20 - 0x3F
If a re-synchronization is necessary, it is best to re-initialize the part either by hardware or software reset (command 0x80), as the state of the part may be unknown.
5.14 Register Paging
Read/write commands access one of the 32 registers within a specified page. By default, Page = 0. To access
Figure 12. CS5467 Memory Map
Example: Reading register 6 in page 3. 1. Write 3 to page register with command and data: 0x7E 0x00 0x00 0x03 2. Read register 6 with command: 0x0C 0xFF 0xFF 0xFF
DS714A1
23
ADVANCE RELEASE
CS5467
5.15 Commands
All commands are 8 bits in length. Any command byte value that is not listed in this section is invalid. Commands that write to registers must be followed by 3 bytes of data. Commands that read data can be chained with other commands (e.g., while reading data, a new command can be sent which can execute during the original read). All commands except register reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.15.1 Start Conversions
B7 1 B6 1 B5 1 B4 0 B3 C3 B2 0 B1 0 B0 0
Initiates acquiring measurements and calculating results. The device has two modes of acquisition. C3 Modes of acquisition/measurement 0 = Perform a single computation cycle 1 = Perform continuous computation cycles
5.15.2 SYNC0 and SYNC1
B7 1 B6 1 B5 1 B4 1 B3 1 B2 1 B1 1 B0 SYNC
The serial port is resynchronized to byte boundaries by sending three or more consecutive SYNC1 commands followed by a SYNC0 command. The SYNC0 or SYNC1 commands can also be used as a NOP command. SYNC Designates calibration 0 = This command is the end of the serial port re-initialization sequence. 1 = This command is part of the serial port re-initialization sequence.
5.15.3 Power-down, Power-up, Halt and Software Reset
B7 1 B6 0 B5 S1 B4 S0 B3 0 B2 0 B1 0 B0 0
To conserve power the CS5467 has two power-down states. In stand-by state all circuitry, except the analog/digital clock generators, is turned off. In the sleep state all circuitry, except the digital clock generator and the command decoder, is turned off. Bringing the CS5467 out of sleep state requires more time than bringing it out of stand-by state, because of the extra time needed to re-start and re-stabilize the analog clock signal. If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all computations will be halted. S[1:0] Power-down state 00 = Software Reset 01 = Halt and enter sleep power saving state. This state requires a slow power-on time 10 = Power-up and Halt 11 = Halt and enter stand-by power saving state. This state allows quick power-on time
24
DS714A1
ADVANCE RELEASE
CS5467
5.15.4 Register Read/Write
B7 0 B6 W/R B5 RA4 B4 RA3 B3 RA2 B2 RA1 B1 RA0 B0 0
The Read/Write informs the command decoder that a register access is required. During a read operation, the addressed register is loaded into the device’s output buffer and clocked out by SCLK. During a write operation, the data is clocked into the input buffer and transferred to the addressed register upon completion of the 24th SCLK. W/R Write/Read control 0 = Read register 1 = Write register Register address bits (bits 5 through 1) of the read/write command.
RA[4:0]
Page 0
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
RA[4:0] 00000 00001 00010 00011 00100 00101 00110 00111 01000 01001 01010 01011 01100 01101 01110 01111 10000 10001 10010 10011 10100 10101 10110 10111 11000 11001 11010 11011 11100 11101 11110 11111
Name Config I V P PActive IRMS VRMS I2 V2 P2 P2Active I2RMS V2RMS QAvg Q Status Q2Avg Q2 Ipeak Vpeak S PF I2peak V2peak S2 PF2 Mask T Ctrl Ppulse Spulse Qpulse / Page
Description Configuration Instantaneous Current Instantaneous Voltage Instantaneous Power Average Active (Real) Power RMS Current RMS Voltage Instantaneous Current 2 Instantaneous Voltage 2 Instantaneous Power 2 Average Active (Real) Power 2 RMS Current 2 RMS Voltage 2 Average Reactive Power Instantaneous Reactive Power Status (Write of ‘1’ to status bit will clear the bit) Average Reactive Power 2 Instantaneous Reactive Power 2 Peak Current Peak Voltage Apparent Power Power Factor Peak Current 2 Peak Voltage 2 Apparent Power 2 Power Factor 2 Mask Temperature Control Active Energy Pulse Output Accumulator Apparent Energy Pulse Output Accumulator Reactive Energy Pulse Output Accumulator (read only) and Page (write only)
Note: For proper operation, do not attempt to write to unspecified registers.
DS714A1
25
ADVANCE RELEASE
CS5467
Page1
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 19 20 21 22 23 26 28
Page2
RA[4:0] 00000 00001 00010 00011 00100 00101 00110 00111 01000 01001 01010 01011 01100 01101 01111 10000 10001 10011 10100 10101 10110 10111 11010 11100
Name Idcoff Ign Vdcoff Vgn Poff Iacoff Vacoff I2dcoff I2gn V2dcoff V2gn P2off I2acoff V2acoff PulseRateE Mode Epsilon Cycle Count QTrig Q2Trig TGain Toff Tmeas SYSgain
Description Current DC offset Current Gain Calibration Voltage DC offset Voltage Gain Calibration Power Offset Current AC (RMS) offset Voltage AC (RMS) offset Current DC offset 2 Current Gain Calibration 2 Voltage DC offset 2 Voltage Gain Calibration 2 Power Offset 2 Current AC (RMS) offset 2 Voltage AC (RMS) offset 2 Sets the energy-to-frequency output pulse rate Operational Modes Epsilon Number of conversions in one computation cycle (N) Reactive Power calculated from Power Triangle Reactive Power calculated from Power Triangle 2 Temperature Sensor Gain Temperature Sensor Offset Temperature Measurement System Gain
Address 0 1 4 5 8 9 12 13
RA[4:0] 00000 00001 00100 00101 01000 01001 01100 01101
Name VSAGduration VSAGlevel ISAGduration ISAGlevel V2SAGduration V2SAGlevel I2SAGduration I2SAGlevel
Description VSAG Duration VSAG Level ISAG Duration ISAG Level VSAG Duration 2 VSAG Level 2 ISAG Duration 2 ISAG Level 2
Note: For proper operation, do not attempt to write to unspecified registers.
26
DS714A1
ADVANCE RELEASE
CS5467
5.15.5 Calibration
B7 1 B6 0 B5 CAL5 B4 CAL4 B3 CAL3 B2 CAL2 B1 CAL1 B0 CAL0
The CS5467 can perform system calibrations. Proper input signals must be applied to the current and voltage channel before performing a designated calibration. CAL[5:4]* Designates calibration to be performed 00 = Channel DC offset 01 = Channel DC gain 10 = Channel AC offset 11 = Channel AC gain Designates channel to calibrate 0001 = Current channel 0010 = Voltage channel 0100 = Current channel 2 1000 = Voltage channel 2
CAL[3:0]*
*By utilizing different combinations for CAL[3:0], multiple channels can be calibrated simultaneously, e.g. CAL[5:0] = 001111 commands the CS5467 to perform a DC offset calibration on all four channels. Values for CAL[5:0] not specified should not be used.
DS714A1
27
ADVANCE RELEASE
CS5467
6. REGISTER DESCRIPTION
1. 2. “Default” = bit status after power-on or reset Any bit not labeled is Reserved. A zero should always be used when writing to one of these bits.
6.1 Page 0 Registers
6.1.1 Configuration (Config) Register
Address: 0
23 PC[7] 15 EWA 7 22 PC[6] 14 6 21 PC[5] 13 5 20 PC[4] 12 IMODE 4 iCPU 19 PC[3] 11 IINV 3 K[3] 18 PC[2] 10 2 K[2] 17 PC[1] 9 1 K[1] 16 PC[0] 8 0 K[0]
Default = 0x000001 PC[7:0] EWA Phase compensation. Sets a delay in the voltage channel relative to the current channel 1. Default setting is 00000000 = 0.0215 degree phase delay at 60 Hz (when MCLK = 4.096 MHz). Allows the E1 and E2 pins to be configured as open-collector output pins. 0 = Normal outputs (default) 1 = Only the pull-down device of the E1 and E2 pins are active Soft interrupt configuration bits. Select the desired pin behavior for indication of an interrupt. 00 = Active-low level (default) 01 = Active-high level 10 = Low pulse 11 = High pulse Inverts the CPUCLK clock. In order to reduce the level of noise present when analog signals are sampled, the logic driven by CPUCLK should not be active during the sample edge. 0 = Normal operation (default) 1 = Minimize noise when CPUCLK is driving rising edge logic Clock divider. A 4-bit binary number used to divide the value of MCLK to generate the internal clock DCLK. The internal clock frequency is DCLK = MCLK/K. The value of K can range between 1 and 16. Note that a value of “0000” will set K to 16 (not zero). K = 1 at reset.
IMODE, IINV
iCPU
K[3:0]
28
DS714A1
ADVANCE RELEASE
CS5467
6.1.2 Instantaneous Current (I, I2), Voltage (V, V2), and Power (P, P2) Registers
Address: 1 (I), 2 (V), 3 (P), 7 (I2), 8 (V2), 9 (P2)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
I (I2) and V (V2)contain the instantaneous measured values for current and voltage, respectively. The instantaneous voltage (voltage 2) and current (current 2) samples are multiplied to obtain Instantaneous Power, P (P2). The value is represented in two's complement notation and in the range of -1.0 ≤ I, V, P < 1.0 (-1.0 ≤ I2, V2, P2 < 1.0), with the binary point to the right of the MSB.
6.1.3 Active (Real) Power (PActive, P2Active) Registers
Address: 4 (PActive), 10 (P2Active)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The instantaneous power is averaged over each computation cycle (N conversions) to compute Active Power, PActive (P2Active). The value will be within in the range of -1.0 ≤ PActive< 1.0 (-1.0 ≤ P2Active< 1.0). The value is represented in two's complement notation, with the binary point to the right of the MSB.
6.1.4 RMS Current (IRMS, I2RMS) & Voltage (VRMS, V2RMS) Registers
Address: 5 (IRMS), 6 (VRMS), 11 (I2RMS), 12 (V2RMS)
MSB 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 ..... 2-18 2-19 2-20 2-21 2-22 2-23 LSB 2-24
IRMS (I2RMS) and VRMS (V2RMS) contain the Root Mean Square (RMS) values of I (I2) and V (V2), calculated each computation cycle. The value is represented in unsigned binary notation and in the range of 0.0 ≤ IRMS, VRMS < 1.0 (0.0 ≤ I2RMS, V2RMS < 1.0), with the binary point to the left of the MSB.
6.1.5 Instantaneous Reactive Power (Q, Q2) Registers
Address: 14 (Q), 17 (Q2)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Instantaneous Reactive Power (Q, Q2) is the product of the voltage (voltage 2) signal, shifted 90 degrees, and the current (current 2) signal. The value is represented in two's complement notation and in the range of -1.0 < Q < 1.0 (1.0 < Q2 < 1.0), with the binary point to the right of the MSB.
6.1.6 Average Reactive Power (QAvg, Q2Avg) Registers
Address: 13 (QAvg), 16 (Q2Avg)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Average Reactive Power (QAVG, Q2AVG) is Q (Q2) averaged over N samples. The value is represented in two's complement notation and in the range of -1.0 < QAVG < 1.0 (-1.0 < Q2AVG < 1.0), with the binary point to the right of the MSB.
DS714A1
29
ADVANCE RELEASE
CS5467
6.1.7 Status (Status) and Mask (Mask) Register
Address: 15 (Status); 26 (Mask)
23 DRDY 15 E2OR 7 TUP 22 I2OR 14 IROR 6 V2OD 21 V2OR 13 VROR 5 I2OD 20 CRDY 12 EOR 4 VOD 19 I2ROR 11 IFAULT 3 IOD 18 V2ROR 10 VSAG 2 LSD 17 IOR 9 I2FAULT 1 FUP 16 VOR 8 V2SAG 0 IC
Default =
0x800001 (Status Register), 0x000000 (Mask Register)
The Status Register indicates status within the chip. In normal operation, writing a '1' to a bit will cause the bit to reset. Writing a '0' to a bit will not change it’s current state. The Mask Register is used to control the activation of the INT pin. Placing a logic '1' in a Mask bit will allow the corresponding bit in the Status Register to activate the INT pin when the status bit is asserted. DRDY IOR (I2OR) VOR (V2OR) CRDY IROR (I2ROR) VROR (V2ROR) EOR (E2OR) Data Ready. During conversions, this bit will indicate the end of computation cycles. For calibrations, this bit indicates the end of a calibration sequence. Current Out of Range. Set when the magnitude of the measured current value causes the I (I2) register to overflow. Voltage Out of Range. Set when the magnitude of the measured voltage value causes the V (V2) register to overflow. Conversion Ready. Indicates a new conversion is ready. This will occur at the output word rate. RMS Current Out of Range. Set when the calculated RMS current value causes the IRMS (I2RMS) register to overflow. RMS Voltage Out of Range. Set when the calculated RMS voltage value causes the VRMS (V2RMS) register to overflow. Energy Out of Range. Set when PActive (P2Active) overflows.
IFAULT (I2FAULT) Indicates a current fault occurred in the power line current. If the absolute value of the instantaneous current is less than ISAGlevel (I2SAGlevel) for more than half of the ISAGduration (I2SAGduration), the IFAULT (I2FAULT) bit will be set. VSAG (V2SAG) Indicates a voltage sag occurred in the power line voltage. If the absolute value of the instantaneous voltage is less than VSAGlevel (V2SAGlevel) for more than half of the VSAGduration (V2SAGduration), the VSAG (V2SAG) bit will be set. Temperature Updated. Indicates a temperature conversion is ready. Modulator Oscillation Detected on the voltage (voltage 2) channel. Set when the modulator oscillates due to an input above full scale. The level at which the modulator oscillates is significantly higher than the voltage (voltage 2) channel’s differential input voltage range. Modulator Oscillation Detected on the current (current 2) channel. Set when the modulator oscillates due to an input above full scale. The level at which the modulator oscillates is significantly higher than the current (current 2) channel’s differential input voltage range. Note: The IOD (I2OD) and VOD (V2OD) bits may be ‘falsely’ triggered by very brief voltage
TUP VOD (V2OD)
IOD (I2OD)
30
DS714A1
ADVANCE RELEASE
CS5467
spikes from the power line. This event should not be confused with a DC overload situation at the inputs, when the IOD (I2OD) and VOD (V2OD) bits will re-assert themselves even after being cleared, multiple times. LSD Low Supply Detect. Set when the voltage at the PFMON pin falls below the low-voltage threshold (PMLO), with respect to AGND pin. For a given part, PMLO can be as low as 2.3 V. LSD bit cannot be permanently reset until the voltage at PFMON pin rises back above the high-voltage threshold (PMHI), which is typically 100 mV above the device’s low-voltage threshold. PMHI will never be greater than 2.7 V. Epsilon Updated. Indicates an update to the epsilon value has been placed in the register. Invalid Command. Normally logic 1. Set to logic 0 if the host interface is strobed with an 8-bit word that is not recognized as one of the valid commands (see See Section 5.15 Commands on page 24).
FUP IC
6.1.8 Peak Current (Ipeak, I2peak) and Peak Voltage (Vpeak, V2peak) Register
Address: 18 (Ipeak), 19 (Vpeak), 22 (I2peak), 23 (V2peak)
MSB -(2 )
0
LSB 2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2-17
2
-18
2
-19
2
-20
2
-21
2
-22
2-23
The Peak Current (Ipeak, I2peak) and Peak Voltage (Vpeak, V2peak) registers contain the instantaneous current and voltage with the greatest magnitude detected during the last computation cycle. The value is represented in two's complement notation and in the range of -1.0 ≤ Ipeak, Vpeak < 1.0 (-1.0 ≤ I2peak, V2peak < 1.0), with the binary point to the right of the MSB.
6.1.9 Apparent Power (S, S2) Register
Address: 20 (S), 24 (S2)
MSB -(2
0)
LSB 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Apparent power S (S2) is the product of the VRMS and IRMS (V2RMS and I2RMS), The value is represented in unsigned notation and in the range of 0 ≤ S < 1.0 (0 ≤ S2 < 1.0), with the binary point to the right of the MSB.
6.1.10 Power Factor (PF, PF2) Register
Address: 21 (PF), 25 (PF2)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Power Factor is calculated by dividing the Active (Real) Power by Apparent Power. The value is represented in two's complement notation and in the range of -1.0 ≤ PF < 1.0 (-1.0 ≤ PF2 < 1.0), with the binary point to the right of the MSB.
DS714A1
31
ADVANCE RELEASE
CS5467
6.1.11 Temperature (T) Register
Address: 27
MSB -(27) 26 25 24 23 22 21 20 ..... 2-10 2-11 2-12 2-13 2-14 2-15 LSB 2-16
T contains measurements from the on-chip temperature sensor. Measurements are performed during continuous conversions, with the default the Celsius scale (oC). The value is represented in two's complement notation and in the range of -128.0 ≤ T < 128.0, with the binary point to the right of the eighth MSB.
6.1.12 Control (Crtl) Register
Register Address: 28
23 PC2[7] 15 7 22 PC2[6] 14 6 21 PC2[5] 13 5 Igain 20 PC2[4] 12 I2gain 4 INTOD 19 PC2[3] 11 3 18 PC2[2] 10 2 NOCPU 17 PC2[1] 9 1 NOOSC 16 PC2[0] 8 STOP 0 -
Default = 0x000000 PC2[7:0] Igain (I2gain) Phase compensation. Sets a delay in the voltage channel relative to current channel 2. Default setting is 00000000 = 0.0215 degree phase delay at 60 Hz (when MCLK = 4.096 MHz). Sets the gain of the current (current 2) PGA. 0 = Gain is 10 (default) 1 = Gain is 50 Terminates the auto-boot sequence. 0 = Normal (default) 1 = Stop sequence Converts INT output pin to an open drain output. 0 = Normal (default) 1 = Open drain Saves power by disabling the CPUCLK pin. 0 = Normal (default) 1 = Disables CPUCLK Saves power by disabling the crystal oscillator. 0 = Normal (default) 1 = Disabling oscillator circuit
STOP
INTOD
NOCPU
NOOSC
32
DS714A1
ADVANCE RELEASE
CS5467
6.1.13 Active Energy Pulse Output Accumulator (Ppulse) Register
Address: 29
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Active Energy Pulse Output Accumulator (Ppulse) contains the average active energy measured on channels 1 & 2 and is used to drive the pulse output. The value is represented in two's complement notation and in the range of -1.0 ≤ Ppulse < 1.0, with the binary point to the right of the MSB.
6.1.14 Apparent Energy Pulse Output Accumulator (Spulse) Register
Address: 30
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Apparent Energy Pulse Output Accumulator (Spulse) contains the average apparent power measured on channels 1 & 2 and is used to drive the pulse output. This result is updated after each computation cycle. The value is represented in two's complement notation and in the range of -1.0 ≤ Spulse < 1.0, with the binary point to the right of the MSB.
6.1.15 Reactive Energy Pulse Output Accumulator (Qpulse) Register
Address: 31 (read only)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Reactive Energy Pulse Output Accumulator (Qpulse) contains the average reactive power measured channels 1 & 2 and is used to drive the pulse output. The value is represented in two's complement notation and in the range of -1.0 ≤ Qpulse < 1.0, with the binary point to the right of the MSB.
6.1.16 Page Register
Address: 31 (write only)
MSB 26 25 24 23 22 21 LSB 20
Default = 0x00 Determines which register page the serial port will access.
DS714A1
33
ADVANCE RELEASE
CS5467
6.2 Page 1 Registers
6.2.1 Current DC Offset (Idcoff, I2dcoff) and Voltage DC Offset (Vdcoff, V2dcoff) Registers
Address: 0 (Idcoff), 2 (Vdcoff), 7 (I2dcoff), 9 (V2dcoff)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Default = 0x000000 The DC Offset registers (Idcoff,Vdcoff, I2dcoff,V2dcoff) are initialized to 0.0 on reset. When DC Offset calibration is performed, the register is updated with the DC offset measured over a computation cycle. DRDY will be set at the end of the calibration. This register may be read and stored for future system offset compensation. The value is represented in two's complement notation and in the range of -1.0 ≤ Idcoff, Vdcoff < 1.0 (-1.0 ≤ I2dcoff, V2dcoff < 1.0), with the binary point to the right of the MSB. See Section 7.1.2.1 DC Offset Calibration Sequence on page 39 for more information.
6.2.2 Current Gain (Ign, I2gn) and Voltage Gain (Vgn, V2gn) Registers
Address: 1 (Ign), 3 (Vgn), 8 (I2gn), 10 (V2gn)
MSB 21 20 2-1 2-2 2-3 2-4 2-5 2-6 ..... 2-16 2-17 2-18 2-19 2-20 2-21 LSB 2-22
Default = 0x400000 = 1.000 The gain registers (Ign,Vgn, I2gn,V2gn) are initialized to 1.0 on reset. When either a AC or DC Gain calibration is performed, the register is updated with the gain measured over a computation cycle. DRDY will be set at the end of the calibration. This register may be read and stored for future system gain compensation. The value is in the range 0.0 ≤ Ign,Vgn < 3.9999 (0.0 ≤ I2gn,V2gn < 3.9999), with the binary point to the right of the second MSB.
6.2.3 Power Offset (Poff, P2off) Registers
Address: 4 (Poff), 11 (P2off)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Default = 0x000000 Power Offset (Poff, P2off) is added to the instantaneous power being accumulated in the Pactive (P2active) register, and can be used to offset contributions to the energy result that are caused by undesirable sources of energy that are inherent in the system. The value is represented in two's complement notation and in the range of -1.0 ≤ Poff < 1.0 (-1.0 ≤ P2off < 1.0), with the binary point to the right of the MSB.
6.2.4 Current AC Offset (Iacoff, I2acoff) and Voltage AC Offset (Vacoff, V2acoff) Registers
Address: 5 (Iacoff), 6 (Vacoff), 12 (I2acoff), 13 (V2acoff)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Default = 0x000000 The AC Offset Registers (Vacoff, Iacoff, V2acoff, I2acoff) are initialized to zero on reset, allowing for uncalibrated normal operation. AC Offset Calibration updates these registers. This sequence lasts approximately (6N + 30) ADC cycles (where N is the value of the Cycle Count Register). DRDY will be asserted at the end of the calibration.
34 DS714A1
ADVANCE RELEASE
CS5467
These values may be read and stored for future system AC offset compensation. The value is represented in two's complement notation in the range of -1.0 ≤ Vacoff, Iacoff < 1.0 (-1.0 ≤ V2acoff, I2acoff < 1.0), with the binary point to the right of the MSB.
6.2.5 PulseRateE Register
Address: 15
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Default = 0x800000 = 1.00 (2 kHz @ 4.096 MHz MCLK)
PulseRateE sets the frequency of E1, E2, & E3 pulses. E1, E2, E3 frequency = (MCLK x PulseRateE) / 2048 at full scale. For a 4 khz sample rate, the maximum pulse rate is 2 khz. The value is represented in two's complement notation and in the range is -1.0 ≤ PulseRateE < 1.0, with the binary point to the right of the MSB. Negative values have the same effect as positive. See Section 5.5 Energy Pulse Output on page 18 for more information.
6.2.6 Operational Mode (Mode) Register
Address: 16
23 15 7 IHPF2 22 14 6 VHPF 21 13 5 IHPF 20 12 4 19 11 3 E3MODE[1] 18 10 2 E3MODE[0] 17 9 E2MODE 1 POS 16 8 VHPF2 0 AFC
Default = 0x000000 E2MODE E2 Output Mode 0 = Sign of Active Power (default) 1 = Apparent Power
VHPF(VHPF2) Enables the High Pass Filter on the voltage channel. 0 = High-pass filter disabled (default) 1 = High-pass filter enabled IHPF(IHPF2) Enables the High Pass Filter on the current channel. 0 = High-pass filter disabled (default) 1 = High-pass filter enabled E3 Output Mode 00 = Reactive Power (default) 01 = PFMON 10 = Voltage sign 11 = Apparent Power Positive Energy Only. Negative energy pulses on E1 are suppressed. However, negative P register results will NOT be suppressed. Enables automatic line frequency measurement and sets the frequency of the local sine/cosine generator used in fundamental/harmonic measurements. When AFC is enabled, the Epsilon register will be updated periodically.
E3MODE1:0
POS AFC
DS714A1
35
ADVANCE RELEASE
6.2.7 Epsilon (ε) Register
Address: 17
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21
CS5467
LSB 2-22 2-23
Default = 0x01999A = 0.0125 sec Epsilon (ε) is the ratio of the input line frequency to the sample frequency of the ADC (See Section 5.4 Performing Measurements on page 17). Epsilon is either written to the register, or measured during conversions. The value is represented in two's complement notation and in the range of -1.0 ≤ ε < 1.0, with the binary point to the right of the MSB. Negative values have no significance.
6.2.8 Cycle Count Register
Address: 19
MSB 223 222 221 220 219 218 217 216 ..... 26 25 24 23 22 21 LSB 20
Default = 0x000FA0 = 4000 Cycle Count, denoted as N, determines the length of one computation cycle. During continuous conversions, the computation cycle frequency is (MCLK/K)/(1024∗N). A one second computational cycle period occurs when MCLK = 4.096 MHz, K = 1, and N = 4000.
6.2.9 Reactive Power (QTrig, Q2Trig) Registers
Address: 20 (QTrig), 21 (Q2Trig)
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
The Reactive Power (QTrig, Q2Trig) is calculated using trigonometric identities. (See Section 4.3 Power Measurements on page 15). The value is represented in unsigned notation and in the range of 0 ≤ QTrig < 1.0 (0 ≤ Q2Trig < 1.0), with the binary point to the right of the MSB.
6.2.10 Temperature Gain (TGain) Register
Address: 22
MSB 26 25 24 23 22 21 20 2-1 ..... 2-11 2-12 2-13 2-14 2-15 2-16 LSB 2-17
Default = 0x34E2E7 = 26.443169117 Temperature gain (TGain) is utilized to convert from one temperature scale to another. The Celsius scale (oC) is the default. Values will be within in the range of 0 ≤ TGain < 128. The value is represented in unsigned notation, with the binary point to the right of bit 7th MSB.
36
DS714A1
ADVANCE RELEASE
CS5467
6.2.11 Temperature Offset (Toff) Register
Address: 23
MSB -(20) 2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 LSB 2-23
Default = 0xF38701 = -0.0974425 Temperature offset (Toff) is used to remove the temperature channel’s offset at the zero-degree reading. Values are represented in two's complement notation and in the range of -1.0 ≤ Toff < 1.0, with the binary point to the right of the MSB.
6.2.12 Temperature Measurement (Tmeas ) Register
Address: 26
MSB 223 222 221 220 219 218 217 216 ..... 26 25 24 23 22 21 LSB 20
Default = 0x000000 The Temperature Measurement register is used to cycle-steal voltage channel 2 for temperature measurement. Writing a one to the LSB causes the temperature to be measured and the Temperature register (T) to be updated.
6.2.13 System Gain Register ( SYSGain )
Address: 28
MSB -(21) 20 2-1 2-2 2-3 2-4 2-5 2-6 ..... 2-16 2-17 2-18 2-19 2-20 2-21 LSB 2-22
Default = 0x500000 = 1.25 System Gain (SYSGain) determines the one’s density of the channel measurements. Small changes in the modulator due to temperature can be fine adjusted by changing the system gain. The value is represented in two's complement notation and in the range of -2.0 < SYSGain < 2.0, with the binary point to the right of the second MSB.
DS714A1
37
ADVANCE RELEASE
CS5467
6.3 Page 2 Registers
6.3.1 Voltage Sag Duration (VSAGduration, V2SAGduration) Registers
Address: 0 (VSAGduration), 8 (V2SAGduration)
MSB 0 LSB 222 221 220 219 218 217 216 ..... 26 25 24 23 22 21 20
Default = 0x000000 Voltage Sag Duration (VSAGduration, V2SAGduration) defines the number of instantaneous measurements utilized to determine a sag event. Setting these register to zero will disable this feature. The value is represented in unsigned notation. See Section 5.6 Sag and Fault Detect Feature on page 20
6.3.2 Current Fault Duration (ISAGduration, I2SAGduration) Registers
Address: 4 (ISAGduration), 12 (I2SAGduration)
MSB 0 LSB 222 221 220 219 218 217 216 ..... 26 25 24 23 22 21 20
Default = 0x000000 Current Fault Duration (ISAGduration, I2SAGduration) defines the number of instantaneous measurements utilized to determine a sag event. Setting these register to zero will disable this feature. The value is represented in unsigned notation. See Section 5.6 Sag and Fault Detect Feature on page 20.
6.3.3 Voltage Sag Level (VSAGlevel, V2SAGLevel) Registers
Address: 1 (VSAGlevel), 9 (V2SAGlevel)
MSB 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 ..... 2-18 2-19 2-20 2-21 2-22 2-23 LSB 2-24
Default = 0x000000 Voltage Sag Level (VSAGlevel), V2SAGlevel) defines the voltage level that the magnitude of input samples, averaged over the sag duration, must fall below in order to register a sag condition. These value are represented in unsigned notation and in the range of 0 ≤ VSAGlevel < 1.0 (0 ≤ V2SAGlevel < 1.0), with the binary point to the left of the MSB. See Section 5.6 Sag and Fault Detect Feature on page 20.
6.3.4 Current Fault Level (ISAGlevel, I2SAGlevel) Registers
Address: 5 (ISAGlevel), 13 (I2SAGlevel)
MSB 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 ..... 2-18 2-19 2-20 2-21 2-22 2-23 LSB 2-24
Default = 0x000000 Current Fault Level (ISAGlevel, I2SAGlevel) defines the voltage level that the magnitude of input samples, averaged over the fault duration, must fall below in order to register a fault condition. These value are represented in unsigned notation and in the range of 0 ≤ ISAGlevel < 1.0 (0 ≤ I2SAGlevel < 1.0), with the binary point to the left of the MSB. See Section 5.6 Sag and Fault Detect Feature on page 20.
38
DS714A1
ADVANCE RELEASE
CS5467
7. SYSTEM CALIBRATION
7.1 Channel Offset and Gain Calibration
The CS5467 provides digital DC offset and gain compensation that can be applied to the instantaneous voltage and current measurements, and AC offset compensation to the voltage and current RMS calculations. Since the voltage and current channels have independent offset and gain registers, system offset and/or gain can be performed on either channel without the calibration results from one channel affecting the other. The computational flow of the calibration sequences are illustrated in Figure 13. The flow applies to both the voltage channel and current channel. N + 30 conversion cycles to complete. For AC offset calibrations, the sequence takes at least 6N + 30 ADC cycles to complete, (about 6 computation cycles). As N is increased, the accuracy of calibration results will increase.
7.1.2 Offset Calibration Sequence
For DC and AC offset calibrations, the VIN± (V2IN±) pins of the voltage and IIN± (I2IN±) pins of the current channels should be connected to their ground reference level. (see Figure 14.)
External Connections + AIN+ 0V + CM + AINXGAIN +
7.1.1 Calibration Sequence
The CS5467 must be operating in its active state and ready to accept valid commands. Refer to 5.15 Commands on page 24. The calibration algorithms are dependent on the value N in the Cycle Count Register (see Figure 13). Upon completion, the results of the calibration are available in their corresponding register. The DRDY bit in the Status Register will be set. If the DRDY bit is to be output on the INT pin, the DRDY bit in the Mask Register must be set. The initial values in the AC gain and offset registers do affect the results of the calibration results.
Figure 14. System Calibration of Offset
The AC offset registers must be set to the default (0x000000).
7.1.2.1 DC Offset Calibration Sequence
Channel gain should be set to 1.0 when performing DC offset calibration. Initiate a DC offset calibration. The DC offset registers are updated with the negative of the average of the instantaneous samples collected over a computational cycle. Upon completion of the DC offset calibration the DC offset is stored in the corresponding DC offset register. The DC offset value will be added to
Instantaneous V, I, V2, I2
7.1.1.1 Duration of Calibration Sequence
The value of the Cycle Count Register (N) determines the number of conversions performed by the CS5467 during a given calibration sequence. For DC offset and gain calibrations, the calibration sequence takes at least
In
Modulator
Filter
+
+
X
X
+ DC Offset Idcoff, Vdcoff, I2dcoff, V2dcoff
Σ
N
÷N
√
+
+ +
RMS IRMS, VRMS, I2RMS, V2RMS
Gain Ign, Vgn, I2gn, V2gn
Σ
N
Iacoff, Vacoff, I2acoff, V2acoff AC Offset
Inverse
÷N
-1
X
-1
X
0.6 RMS = NAMES OF READABLE/WRITABLE REGISTERS.
Figure 13. Calibration Data Flow
DS714A1
39
ADVANCE RELEASE
CS5467
each instantaneous measurement to nullify the DC component present in the system during conversion commands.
measurement will be multiplied by its corresponding AC gain value. A typical rms calibration value which allows for reasonable over-range margin would be 0.6 or 60% of the voltage and current channel’s maximum input voltage level. Two examples of AC gain calibration and the updated digital output codes of the channel’s instantaneous data registers are shown in Figure 16 and 17. Figure 17
Before AC Gain Calibration (Vgn Register = 1)
250 mV
Sinewave
7.1.2.2 AC Offset Calibration Sequence
Corresponding offset registers Iacoff (I2acoff) and/or Vacoff (V2acoff) should be cleared prior to initiating AC offset calibrations. Initiate an AC offset calibration.The AC offset registers are updated with an offset value that reflects the RMS output level. Upon completion of the AC offset calibration the AC offset is stored in the corresponding AC offset register. The AC offset register value is subtracted from each successive VRMS and IRMS calculation.
0.9999... 0.92 Instantaneous Voltage Register Values -0.92 -1.0000...
230 mV
INPUT 0V SIGNAL
-230 mV
7.1.3 Gain Calibration Sequence
When performing gain calibrations, a reference signal should be applied to the VIN± (V2IN±) pins of the voltage and IIN± (I2IN±) pins of the current channels that represents the desired maximum signal level. Figure 15 shows the basic setup for gain calibration.
External Connections
R eference + Signal -
-250 mV
VRMS Register = 230/√2 x 1/250 ≈ 0.65054
After AC Gain Calibration (Vgn Register changed to approx. 0.9223)
250 mV
Sinewave
0.92231 0.84853 Instantaneous Voltage Register Values -0.84853 -0.92231
230 mV
IN+
+
XG AIN
+ -
INPUT 0V SIGNAL
-230 mV -250 mV
CM
VRMS Register = 0.600000
+ -
IN-
Figure 16. Example of AC Gain Calibration
Figure 15. System Calibration of Gain.
Before AC Gain Calibration (Vgain Register = 1)
250 mV 230 mV
DC Signal
For gain calibrations, there is an absolute limit on the RMS voltage levels that are selected for the gain calibration input signals. The maximum value that the gain registers can attain is 4. Therefore, if the signal level of the applied input is low enough that it causes the CS5467 to attempt to set either gain register higher than 4, the gain calibration result will be invalid and all CS5467 results obtained while performing measurements will be invalid. If the channel gain registers are initially set to a gain other than 1.0, AC gain calibration should be used.
0.9999... 0.92 Instantaneous Voltage Register Values
INPUT 0 V SIGNAL
-250 mV
230 VRMS Register = 250 = 0.92
-1.0000...
After AC Gain Calibration (Vgain Register changed to approx. 0.65217)
250 mV 230 mV
DC Signal
0.65217 0.6000 Instantaneous Voltage Register Values
7.1.3.1 AC Gain Calibration Sequence
The corresponding gain register should be set to 1.0, unless a different initial gain value is desired. Initiate an AC gain calibration. The AC gain calibration algorithm computes the RMS value of the reference signal applied to the channel inputs. The RMS register value is then divided into 0.6 and the quotient is stored in the corresponding gain register. Each instantaneous
INPUT 0V SIGNAL
-250 mV
-0.65217
VRMS Register = 0.600000
Figure 17. Example of AC Gain Calibration
40
DS714A1
ADVANCE RELEASE
CS5467
shows that a positive (or negative) DC-level signal can be used even though an AC gain calibration is being executed. However, an AC signal cannot be used for DC gain calibration.
multiplying the AC offset register value that was calculated in step 2 by the gain calculated in step 3 and updating the AC offset register with the product.
7.2 Phase Compensation
The CS5467 is equipped with phase compensation to cancel out phase shifts introduced by the measurement element. Phase Compensation is set by bits PC[7:0] (for channel 1) in the Configuration Register and bits PC2[7:0] (for channel 2) in the Control Register The default value of PC[7:0] (PC2[7:0]) is zero. With MCLK = 4.096 MHz and K = 1, the phase compensation has a range of ±5.4 degrees when the input signals are 60 Hz. Under these conditions, each step of the phase compensation register (value of one LSB) is approximately 0.04 degrees. For values of MCLK other than 4.096 MHz, the range and step size should be scaled by 4.096 MHz/(MCLK/K). For power line frequencies other than 60Hz, the values of the range and step size of the PC[7:0] (PC2[7:0]) bits can be determined by converting the above values from angular measurement into the time domain (seconds), and then computing the new range and step size (in degrees) with respect to the new line frequency. To calculate the phase shift induced between the voltage and the current channel use the equation:
o Freq × 360 × PC [ 7:0 ] = -------------------------------------------------( MCLK ⁄ K ) ⁄ 8
7.1.3.2 DC Gain Calibration Sequence
Initiate a DC gain calibration. The corresponding gain register is restored to default (1.0). The DC gain calibration averages the channel’s instantaneous measurements over one computation cycle (N samples). The average is then divided into 1.0 and the quotient is stored in the corresponding gain register After the DC gain calibration, the instantaneous register will read at full-scale whenever the DC level of the input signal is equal to the level of the DC calibration signal applied to the inputs during the DC gain calibration.The HPF option should not be enabled if DC gain calibration is utilized.
7.1.4 Order of Calibration Sequences
1. If the HPF option is enabled, any DC component that may be present in the selected signal path will be removed and a DC offset calibration is not required. However, if the HPF option is disabled the DC offset calibration sequence should be performed. When using high-pass filters, it is recommended that the DC Offset register for the corresponding channel be set to zero. When performing DC offset calibration, the corresponding gain channel should be set to one. 2. If there is an AC offset in the VRMS or IRMS calculation, the AC offset calibration sequence should be performed. 3. Perform the gain calibration sequence. 4. Finally, if an AC offset calibration was performed (step 2), the AC offset may need to be adjusted to compensate for the change in gain (step 3). This can be accomplished by restoring zero to the AC offset register and performing an AC offset calibration sequence. The adjustment could also be done by
Phase
Freq = Line Frequency [Hz] PC[7:0] = 2’s Compliment number in the range of -128 < PC[7:0} < 127
7.3 Active Power Offset
The Power Offset Register can be used to offset system power sources that may be resident in the system, but do not originate from the power line signal. These sources of extra energy in the system contribute undesirable and false offsets to the power and energy measurement results. After determining the amount of stray power, the Power Offset Register can be set to cancel the effects of this unwanted energy.
DS714A1
41
ADVANCE RELEASE
CS5467
8. AUTO-BOOT MODE USING E2PROM
When the CS5467 MODE pin is asserted (logic 1), the CS5467 auto-boot mode is enabled. In auto-boot mode, the CS5467 downloads the required commands and register data from an external serial E2PROM, allowing the CS5467 to begin performing energy measurements.
8.2 Auto-boot Data for E2PROM
Below is an example code set for an auto-boot sequence. This code is written into the E2PROM by the user. The serial data for such a sequence is shown below in single-byte hexidecimal notation:
-7E 00 00 01 Change to page 1. -60 00 01 E0 Write Operation Mode Register, turn high-pass filters on. -42 7F C4 A9 Write value of 0x7FC4A9 to Current Gain Register. -46 FF B2 53 Write value of 0xFFB253 to Voltage Gain Register. -50 7F C4 A9 Write value of 0x7FC4A9 to Current 2 Gain Register. -54 FF B2 53 Write value of 0xFFB253 to Voltage 2 Gain Register. -7E 00 00 00 Change to page 0. -74 00 00 04 Unmask bit #2 (LSD) in the Mask Register. -E8 Start continuous conversions -78 00 01 00 Write STOP bit to Control Register, to terminate auto-boot initialization sequence.
8.1 Auto-boot Configuration
A typical auto-boot serial connection between the CS5467 and a E2PROM is illustrated in Figure 18. In auto-boot mode, the CS5467’s CS and SCLK are configured as outputs. The CS5467 asserts CS (logic 0), provides a clock on SCLK, and sends a read command to the E2PROM on SDO. The CS5467 reads the user-specified commands and register data presented on the SDI pin. The E2PROM’s programmed data is utilized by the CS5467 to change the designated registers’ default values and begin registering energy.
VD+ E1 E2 5K
Pulse Output Counter
CS5467
SCLK SDI SDO MODE CS
5K
EEPROM
SCK SO SI CS
Connector to Calibrator
Figure 18. Typical Interface of E2PROM to CS5467
Figure 18 also shows the external connections that would be made to a calibrator device, such as a PC or custom calibration board. When the metering system is installed, the calibrator would be used to control calibration and/or to program user-specified commands and calibration values into the E2PROM. The user-specified commands/data will determine the CS5467’s exact operation, when the auto-boot initialization sequence is running. Any of the valid commands can be used.
8.3 Which E2PROMs Can Be Used?
Several industry-standard serial E2PROMs that will successfully run auto-boot with the CS5467 are listed below:
• • • Atmel AT25010, AT25020 or AT25040 National Semiconductor NM25C040M8 or NM25020M8 Xicor X25040SI
These types of serial E2PROMs expect a specific 8-bit command (00000011) in order to perform a memory read. The CS5467 has been hardware programmed to transmit this 8-bit command to the E2PROM at the beginning of the auto-boot sequence.
42
DS714A1
ADVANCE RELEASE
CS5467
9. BASIC APPLICATION CIRCUITS
Figure 19 shows the CS5467 configured to measure power in a single-phase, 3-wire system while operating in a single-supply configuration. In this diagram, a current transformer (CT) is used to sense the line current and a voltage divider is used to sense the line voltage.
5 kΩ L2 N L1 500 Ω 2 uF 500 470 µF 0.1 µF 10 Ω 0.1 µF 18 VA+ 3 VD+
10 kΩ
9 CVR 2 R1
VIN1+
CVdiff R VCV+ 10 13 CVR
1
CS5467
VIN1VIN2+ PFMON CPUCLK XOUT 21 2 1 4.096 MHz 28 Optional Clock Source
R2
CVdiff R VCV+ 14 R I1kΩ C Idiff 1kΩ RI+ 20 R I1kΩ C Idiff 16 RI+ 12
11
XIN VIN2-
19
IIN1RESET
23 ISOLATION Serial Data Interface
CT
RBurden
IIN1+
RBurden
15
IIN2-
CT
1kΩ
7 CS 27 SDI 6 SDO 5 SCLK 24 INT 26 E2 25 E1
IIN2+ VREFIN VREFOUT AGND 17 DGND 4
Pulse Output Counter
LOAD
LOAD
0.1 µF
Figure 19. Typical Connection Diagram (Single-phase, 3-wire – Direct Connect to Power Line)
DS714A1
43
ADVANCE RELEASE
CS5467
10.PACKAGE DIMENSIONS
28L SSOP PACKAGE DRAWING
N
D
E11 A2 A1 SEATING PLANE
E
A
∝
L
e
b2 SIDE VIEW
END VIEW
12 3
TOP VIEW
DIM A A1 A2 b D E E1 e L
∝
MIN -0.002 0.064 0.009 ? 0.291 0.197 0.022 0.025 0°
INCHES NOM -0.006 0.068 -? 0.307 0.209 0.026 0.03 4°
MAX 0.084 0.010 0.074 0.015 ? 0.323 0.220 0.030 0.041 8°
MIN -0.05 1.62 0.22 ? 7.40 5.00 0.55 0.63 0°
MILLIMETERS NOM -0.13 1.73 -? 7.80 5.30 0.65 0.75 4°
NOTE MAX 2.13 0.25 1.88 0.38 ? 8.20 5.60 0.75 1.03 8°
2,3 1 1
JEDEC #: MO-150
Controlling Dimension is Millimeters. Notes: 3. “D” and “E1” are reference datums and do not included mold flash or protrusions, but do include mold mismatch
4. and are measured at the parting line, mold flash or protrusions shall not exceed 0.20 mm per side. Dimension “b” does not include dambar protrusion/intrusion. Allowable dambar protrusion shall be 0.13 mm total in excess of “b” dimension at maximum material condition. Dambar intrusion shall not reduce dimension “b” by more than 0.07 mm at least material condition. 5. These dimensions apply to the flat section of the lead between 0.10 and 0.25 mm from lead tips.
44
DS714A1
ADVANCE RELEASE
CS5467
11. ORDERING INFORMATION
Model Temperature Package
CS5467-IS CS5467-ISZ (lead free)
-40 to +85 °C
28-pin SSOP
12. ENVIRONMENTAL, MANUFACTURING, & HANDLING INFORMATION
Model Number Peak Reflow Temp 240 °C 260 °C MSL Rating* 2 3 Max Floor Life 365 Days 7 Days
CS5467-IS CS5467-ISZ (lead free)
* MSL (Moisture Sensitivity Level) as specified by IPC/JEDEC J-STD-020.
DS714A1
45
ADVANCE RELEASE
CS5467
13. REVISION HISTORY
Revision Date Changes
A1
MAR 2006
Advance Release
Contacting Cirrus Logic Support
For all product questions and inquiries contact a Cirrus Logic Sales Representative. To find the one nearest to you go to www.cirrus.com
IMPORTANT NOTICE “Advance” product information describes products that are in development and subject to development changes. Cirrus Logic, Inc. and its subsidiaries (“Cirrus”) believe that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided “AS IS” without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights, copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN AIRCRAFT SYSTEMS, MILITARY APPLICATIONS, PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER'S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS' FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES. Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks or service marks of their respective owners. SPI is a trademark of Motorola, Inc. Microwire is a trademark of National Semiconductor Corporation.
46
DS714A1