0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A20442MNZBF

A20442MNZBF

  • 厂商:

    CK-COMPONENTS(C&K)

  • 封装:

    -

  • 描述:

    SWITCHROTARY4POS0.4VA20V

  • 数据手册
  • 价格&库存
A20442MNZBF 数据手册
A Series 1-4 Pole Rotary Switches Features/Benefits • Multi-pole and multi-position • Positive detent • Shorting & non-shorting contacts • Panel and PCB mounting • RoHS Compliant Typical Applications • Automotive • Major and small appliances • Industrial equipment Models Available Specifications Materials CONTACT RATING: Q contact material: Switch - 2.5 AMPS @ 125 V AC; 1 AMP @ 250 V AC; 350 mA @ 125 V DC (UL/CSA). Carry - 5 AMPS continuous. See page K-6 for additional ratings. ELECTRICAL LIFE: Up to 15,000 make-and-break cycles at full load up to 300,000 detent operations. CONTACT RESISTANCE: Below 20 m Ω typ. initial @ 2-4 V DC, 100 mA, for both silver and gold plated contacts. INSULATION RESISTANCE: 10 9 Ω min. DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level. ­Operating and storage temp: -30º to 85ºC OPERATING & STORAGE TEMPERATURE: -30ºC to 85ºC HOUSING & BUSHING: Glass filled 6/6 nylon (UL 94V-0). ACTUATOR: Glass filled 6/6 nylon (UL 94V-0). MOVABLE CONTACTS: Q contact material: Coin silver, silver plated. See page K-6 for additional contact materials. STATIONARY CONTACTS & TERMINALS: Q contact material: Brass, silver plated. See page K-6 for additional contact materials. HARDWARE: Nut - zinc, nickel plated. Lockwasher — steel, bright zinc plated. Stop Ring - brass, nickel plated. TERMINAL SEAL: Epoxy. NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. NOTE: Specifications and materials listed above are for switches with standard options. For information on specific and custom switches, consult Customer Service Center. Build-A-Switch To order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on pages K–4 through K–7. For additional options not shown in catalog, consult Customer Service Center. K Dimensions are shown: Inch (mm) Specifications and dimensions subject to change 20 Apr 21 K–3 www.ckswitches.com Rotary Switch Function A100 SP, 30° Index, 12 pos. no stops A102 SPDT, 30° Index A103 SP, 30° Index, 3 pos. Actuator A104 SP, 30° Index, 4 pos. 15 1.500” high, flatted A105 SP, 30° Index, 5 pos. 03 .375” high, flatted A106 SP, 30° Index, 6 pos. 05 .500” high, flatted A107 SP, 30° Index, 7 pos. 14 1.500” high, flatted A108 SP, 30° Index, 8 pos. 42 1.654” high, metric A109 SP, 30° Index, 9 pos. S1 Screwdriver Slot A110 SP, 30° Index, 10 pos. A112 SP, 30° Index, 12 pos. Mounting Style A114 SP, 90° Index, 2 pos. R 3/8-32 threaded A115 SP, 45° Index, 3 pos. M M10 x .75 metric A124 SP, 90° Index, 4 pos. Shorting/ A125 SP, 45° Index, 8 pos. Non-shorting Contacts A203 DP, 30° Index, 3 pos. N Non-shorting contacts A204 DP, 30° Index, 4 pos. S Shorting contacts A205 DP, 30° Index, 5 pos. (Not available with models A114, A124 & A214) A206 DP, 30° Index, 6 pos. A214 DP, 90° Index, 2 pos. Terminations A303 3P, 30° Index, 3 pos. Z Solder lug A304 3P, 30° Index, 4 pos. C PC Thru-hole Contact Material A402 4PDT, 30° Index MC Modular base Q Silver A403 4P, 30° Index, 3 pos B Gold Seal G Gold over silver NONE No seal E Epoxy seal F Splashproof bushing seal K Epoxy & splashproof bushing seal A Series 1-4 Pole Rotary Switches SWITCH FUNCTION 30º INDEXING NO. POLES 30º INDEXING SP MODELS SCHEMATIC MODEL NO. SWITCH FUNCTION TERMINALS A100 12 Position No Stops A,1-12 A102 SPDT A,1,2* A103 3 Position A,1-3* A104 4 Position A,1-4* A105 5 Position A,1-5* A106 6 Position A,1-6* NO. POLES MODEL NO. SWITCH FUNCTION A402 4PDT A,B,C,D,1,2,4,5,7, 8,10,11 A403 3 Position All Terminals 4P DP MODELS SCHEMATIC SP TERMINALS 45º INDEXING NO. POLES MODEL NO. SWITCH FUNCTION A115 3 Position A,1,2,4* A125 8 Position A,1,2,4,5,7,8,10,11 TERMINALS SP DP K A107 7 Position A,1-7 A108 8 Position A,1-8 A109 9 Position A,1-9 A110 10 Position A,1-10 A112 12 Position A,1-12 A203 3 Position A,C,1-3,7-9 A204 4 Position A,C,1-4,7-10 A205 5 Position A,C,1-5,7-11 A206 6 Position A,C,1-12 A303 3 Position A,B,C,1-3,5-7 9-11 A304 4 Position A,B,C,1-12 Rotary 3P 3P MODELS SCHEMATIC 90º INDEXING NO. POLES MODEL NO. SWITCH FUNCTION A114 2 Position A,1,4* A124 4 Position A,1,4,7,10 A214 2 Position A,C,1,4,7,10 TERMINALS SP 4P MODELS SCHEMATIC DP TERMINAL NUMBERS NOTE: * These models with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. Terminal numbers molded on bottom of housing. All models with all options when ordered with ‘G’ or ‘Q’ contact material, see page K-6. 4P MODELS SP MODELS (omit terminals B, C & D) DP MODELS (omit terminals B & D) 3P MODELS Dimensions are shown: Inch (mm) Specifications and dimensions subject to change 20 Apr 21 K–4 www.ckswitches.com A Series 1-4 Pole Rotary Switches ACTUATOR 15 1.500” HIGH 03 .375” HIGH 05 .500” HIGH 14 1.500” HIGH 42 1.654” METRIC S1 SCREWDRIVER SLOT NOTE: Actuators shown in position 1, fully CCW. MOUNTING STYLE M  M10 x .75 METRIC R  3/8-32 THREAD TYPICAL INSTALLATION Maximum force to push on knob should not exceed 10 lbs. NUT PANEL MOUNTING PANEL MOUNTING Install switch with stop ring (if used) and lockwasher in back of panel. Tighten hex nut from front of panel. On PC mounted switches, use hex nut and lockwasher to hold stop ring in place. Actuation torque: 8–16 oz./in. Maximum torque: 30 oz./in. METRIC BUSHING 3/ IN. BUSHING 8 SHORTING/NON-SHORTING CONTACTS N  NON-SHORTING CONTACTS (break-before-make) S  SHORTING CONTACTS (make-before-break) NOTE: ‘S’ shorting contacts are not available with A114, A124 and A214 models. Dimensions are shown: Inch (mm) Specifications and dimensions subject to change 20 Apr 21 K–5 www.ckswitches.com Rotary LOCKWASHER K A Series 1-4 Pole Rotary Switches TERMINATIONS Z  SOLDER LUG C  PC THRU-HOLE MC  MODULAR BASE (for wave soldering) NOTE: Switches with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. Solder and clean switch base on PC board with other components, then snap on housing/actuator assembly. See page K-7 for installation instructions. PC MOUNTING 4P MODEL SP MODEL (omit terminals B, C & D) DP MODEL (omit terminals B & D) Rotary K 3P MODEL CONTACT MATERIAL Option Code Contact & Terminal Material Q Silver2 Power B Gold1 Low level/ Dry circuit G Gold over silver3 Typical Usage Low level/ Dry circuit or power Rating Cycles SWITCH – 2.5 AMPS @ 125 VAC; 1 AMP @ 250 VAC (UL/CSA) CARRY – 5 AMPS CONTINUOUS 6,000 SWITCH – 350 mA @ 125 VDC (UL/CSA) CARRY – 5 AMPS CONTINUOUS 15,000 0.4 VA MAX. @ 20 V AC OR DC MAX 15,000 0.4 VA MAX. @ 20 V AC OR DC MAX 15,000 SWITCH – 350 mA @ 125 VDC (UL/CSA) CARRY – 5 AMPS CONTINUOUS 15,000 SWITCH – 2.5 AMPS @ 125 VAC; 1 AMP @ 250 VAC (UL/CSA) CARRY – 5 AMPS CONTINUOUS 6,000 * Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications. NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. 1 MOVABLE CONTACTS: Copper alloy, with gold plate over nickel plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate. 2 MOVABLE CONTACTS: Coin silver, silver plated. STATIONARY CONTACTS & TERMINALS: Brass, silver plated (standard with all termination options). 3 MOVABLE CONTACTS: Coin silver, with gold plate over nickel plate over silver plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate over silver plate. All models with all options when ordered with ‘G’ or ‘Q’ contact material. NOTE: ‘G’ contact material is equivalent to both ‘B’ and ‘Q” contact materials. Dimensions are shown: Inch (mm) Specifications and dimensions subject to change 20 Apr 21 K–6 www.ckswitches.com A Series 1-4 Pole Rotary Switches FUNCTION NONE NO SEAL E  EPOXY SEAL F SPLASHPROOF BUSHING SEAL K EPOXY & SPLASHPROOF BUSHING SEAL SPLASHPROOF BUSHING SEAL Setting Stops on A112 and A125 Models The number of switch positions is adjustable on A112 and A125 models only by means of a stop ring provided with each switch. The number of positions is pre-set on all other models and the stop ring is factory installed. To set stops: Turn shaft fully counter-clockwise and insert stop ring tab in desired hole. Install lockwasher and nut to retain stop ring for both PC and panel mounting. Switch without stop ring has 12 positions. Soldering, Cleaning and Assembly Instructions for ‘MC’ Termination Option Soldering 1. Insert switch base only into PC board. 2. Do not bend terminals. 3. Wave soldering recommended at 500F solder temperature. 4. Hand solder at 500F, 10 sec. max./terminal. Cleaning 1. Flux clean using vapor degreaser and forced rinse or triple bath method. 2. Do not allow switch base to ‘trap’ fluids. 3. Freon TMC, TF or Methylene Chloride give excellent results. REMOVABLE CLIP K Rotary Switch Assembly 1. Hold housing/shaft assembly by housing. Remove protective cap by squeezing tabs and discard. (FIG. 1) 2. Do not push on switch shaft. Detent mechanism will come apart. 3. While holding switch housing, align locating tab on base with notch on housing and engage 4 housing latches in slots on base. (FIG. 2) 4. Push firmly on housing until latches snap in place. 5. Remove clip from shaft and discard. Assembly is complete. (FIG. 3) (FIG. 1) LOCATING TAB STANDOFF (FIG. 2) (FIG. 3) AVAILABLE HARDWARE Stop ring PART NO. 767B00201 Material: Brass Finish: Nickel plated Dimensions are shown: Inch (mm) Specifications and dimensions subject to change 20 Apr 21 K–7 www.ckswitches.com
A20442MNZBF 价格&库存

很抱歉,暂时无法提供与“A20442MNZBF”相匹配的价格&库存,您可以联系我们找货

免费人工找货