Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
1/8
Date.: 23/08/2018
C&K Part Number
Designation
Y16WP1500FP
VIEW
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Drawing reference
K12PL GN 1 5N L866
FEATURES
CU16WP1500FP
MAIN FEATURES
- Self cleaning contacts
- Tactile feeling & electrical function separated
- Excellent tactile feedback
- With snap point
The K12PL GN 1 5N L866
- With central Led
is a high performance key
- Actuator type: round, button
switch with separated electrical - Actuator color: Black
- With snap-in pegs
and mechanical functions.
- Terminal plating: Pure Tin
- Compatible with lead free process (wave or
hand soldering only)
- Marking: on product and on packaging box
Summary:
1 - General
2 - Led Characteristics
3 - Switch Rating (Switch activated position)
4 - Operating temperatures
5 - Test conditions
6 - Electrical performance (Switch activated position)
7 - Mechanical performance
8 - Physical data
9 - Environment performance
10 - Durability
11 - Solderability
12 - Packaging
13 - Material declarations
14 - Liabilities
Revision record:
Revision
PS_M
Date
4/25/2018
Comments
ECO-0017730-16
Approved by
laurent.kubat
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
2/8
Product Definition
This specification applies to a key switch. Description: see Features & Main Features page 1.
Dimensions and shapes: according to the product drawing.
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
1/GENERAL
Function: Normally open
Contact type: Single pole single throw
Terminals: THT
Contact plating: Gold
Terminals plating: Lead free tin
Illuminated: YES
Operating direction: Top actuated
Activation type: Momentary action
LED reference: L866
Led color: Green
2/LED
Forward Current (If): 20 mA
CHARACTERISTICS
Typical Forward Voltage: 2.2 V
Maximum Forward Voltage: 2.5 V
Minimum power: 0.02 VA
Maximum power: 3 VA
3/SWITCH
Minimum voltage: 2 V
RATING (Switch
Maximum voltage: 30 V
activated position)
Minimum current: 10 mA
Maximum current: 100 mA
4/OPERATING
TEMPERATURE
5/TEST
CONDITIONS
6/ELECTRICAL
PERFORMANCE
(Switch activated
position)
Contact resistance
(max RC)
Insulation
resistance (min RI)
Minimum operating temperature: -40 °C
Maximum operating temperature: 85 °C
Minimum storage temperature: -40 °C
Maximum storage temperature: 95 °C
Minimum ambiant temperature: 15 °C
Maximum ambiant temperature: 35 °C
Minimum relative humidity: 25 %
Maximum relative humidity: 75 %
Minimum air pressure: 86 kPa
Maximum air pressure: 106 kPa
Samples shall be soldered on the PCB according to their normal process.
Test Conditions / Information
The switch shall be manually actuated. Open circuit
voltage: 20 mV max. Test current: 10 mA max.
The insulation resistance shall be measured between
contacts. Test voltage: 500 Vd.c.
Criteria
0.05 Ohm
10000 MOhm
Duration of application: 60 s ± 5
Dielectric strength
The dielectric strength test shall be performed between
contacts. The applicable test voltage shall be applied for 500 Vrms
a minimum duration of 60 s.
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
3/8
Increase of voltage/time: 500 V/s
Bouncing
(max duration)
The switch shall be manually actuated. Open circuit
voltage: ~ 5 V. Test current: 10 mA.
1 ms
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Bouncing draw
7/MECHANICAL
PERFORMANCE
Test Conditions / Information
Criteria
Curve
Operating Force
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
4/8
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Activation condition
Placing the switch such that the direction of switch
operation is vertical and then gradually increasing the
force applied to the button, the maximum force required
Maximal force: 7 N
Activation force (Fa) before the activation of the electrical contact shall be
Minimal force: 5 N
measured = Fa
Please refer to the curve operating force.
Product height at electrical travel
Electrical height
Remarks:
1 - Electrical travel = travel distance required for the
actuator to establish an electrical contact
2 - Switch height: 11 +0.15/-0.05 mm
3 - Height with PCB as displacement reference
Maximal value: 10.6 mm
Minimal value: 10.3 mm
Product height at max travel
End Travel height
Return force (Frr)
Remarks:
1 - Switch height: 11 +0.15/-0.05 mm
2 - Height with PCB as displacement reference
Same condition as activation force. On depression,
the minimum force within the deactivation area of the
electrical contact = Return force (Frr)
Maximal value: 9.95 mm
Minimal value: 9.75 mm
Minimum force: 0.8 N
Please refer to the curve operating force.
8/PHYSICAL DATA
Information
Dimensions layout According to the product drawing
Weight
CU16WP1500FP
1 Grams
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
9/ENVIRONMENT
PERFORMANCE
Overload
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
5/8
Test Conditions / Information
Samples shall be submitted to an overload without
generating deviation of characteristics in item electrical
and mechanical performances.
Criteria
30 N
One cycle only
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Dry heat
Samples shall be tested in accordance with NF EN
60068-2-2, test Bb; Recovery time: 1 hour.
Item electrical and mechanical
performances shall be satisfied
Temperature: +85°C - Duration: 10 days
Cold
Samples shall be tested in accordance with NF EN
60068-2-1, test Ab; Recovery time: 1 hour.
Items electrical and mechanical
performances shall be satisfied.
Temperature: -40°C - Duration: 10 days
Vibration
Shocks
Thermal shocks
Samples shall be tested in accordance with NF EN
60068-2-6. Vibrations shall be performed in the three
mutually perpendicular axes of the samples.
Duration: 23 min per direction; Sweep frequency:
Items electrical and mechanical
10 to 500 Hz; Frequencies scanning : 1 octave/mn;
performances shall be satisfied.
Displacement or acceleration: 1.5mm or 10g; Number of
cycles in each of the three axis: 2.
Samples shall be tested in accordance with NF EN
60068-2-27. Shocks shall be applied in each direction of
the three major axis of the samples.
Items electrical and mechanical
Impulse: 1/2 sinusoidal. Acceleration: 500 m/sec. Impact
performances shall be satisfied.
duration : 11 ms.Number of shock in each direction of
three axis: 3.
Samples shall be tested in accordance with NF EN
60068-2-14, test Nb; Duration of exposure: 30mn per
temperature; Changing time: 30sec max; Recovery time: Items electrical and mechanical
1 hour.
performances shall be satisfied.
Temperatures: -40°C / +85°C - Number of cycles: 20
Damp heat
Samples shall be tested in accordance with NF EN
60068-2-30, test Cb; Temperature: 55°C+/-2°C; Relative
Items electrical and mechanical
Humidity: 90 to 96 %; Recovery time:1 hour.
performances shall be satisfied.
Number of cycles: 6
IP code
Samples shall be tested in accordance with NF EN
60529.
IP 40
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
6/8
Washing process
Marking
Not compatible
According to the Product drawing.
Chemical agent
Shear test
(max force)
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
10/DURABILITY
Life test
11/
SOLDERABILITY
Soldering profile
With
Not compatible
Switch/PCB: the force shall be applied on the longest
side of the switch, parallel to the PCB
50 N
Test Conditions / Information
Criteria
Operating speed: 60 cycles max per minute. Push force:
Items electrical and mechanical
maximum specified activation force of the switch.
performances shall be satisfied
except Contact resistance which
can reach 2 Ohms.
Number of cycles: 1000K
Test Conditions / Information
Criteria
Wave soldering compatible with lead free soldering
profile ( according to C&K recommendation: following
single wave soldering profile )
Soldering
profile draw
Manual soldering
MSL level
Hand soldering: 350°C / 3s
The Moisture Sensitive Level is defined according to the
standard JEDEC J-STD-020.
Item electrical and mechanical
performances shall be satisfied.
1
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
7/8
12/PACKAGING
Type
Transport
conditions
Information
Box
According to specification NF H00-060.
13/MATERIAL
DECLARATIONS
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Rohs compliance
Low Halogen
compliance
Reach compliance
Declarations
Information
YES
This product is complying with the EU directive 2011/65/EU and with the EU directive
2015/863, without exemption.
YES
YES
Reach compliant, according to the C&K Declaration on Regulation (EC) N° 1907/2006.
Remarks:
1/ Low Halogen compliance, according to the JEDEC/ECA Standard JS709B.
2/ The C&K Reach declaration refers to the current Reach Candidate List of Substances of
Very High Concern published by the European Chemicals Agency.
14/LIABILITIES
Information
Application limits
For applications requiring hight reliability and safety, or for which failure or malfunction of the
product may directly threaten life or personal asset, please contact us. These applications
are (not limited to): - Aircraft and aerospace - Anti disaster and anti crime equipment Medical equipment - Transportation equipment (automotive, train, boat, etc..) - High public
information processing devices Any other device similar to the above.
Change
Please contact your local C&K representative to obtain the latest version before usage.
This specification is a constituent document of contract for business concluded between
Specification validity your company and C&K Components. Any other information such as catalogue pages,
brochures, leaflet, web pages does not constitute contracting information.
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com
CONFIDENTIAL. This document and the information in it is the exclusive property of
C&K and is not to be used or disclose without the express written permission of C&K.
Product specification
Revision
PS_M
Y16WP1500FP - K12PL GN 1 5N L866
Pages
8/8
Recommandation
prohibition
In order to obtain the best results and benefits from the product, and avoiding any accident
or malfunction, we recommend reading and applying the following rules:- Make
sure the product is placed as parallel to the PCB as possible. In case the position needs to
be corrected manually, do not push on the dome or actuator. Please use the body of the
switch to do so.- Safeguard the switch against flux penetration from the top side.This product is not compatible with washing process after reflow soldering.- If heat is
applied repeatedly, the tactile feeling may be affected. Do stay within the recommended
limits and conditions.- If soldering conditions allowed manual soldering, you need
to respect the following precautions in order to avoid any unexpected malfunction of the
switch:- Maximum temperature: 350 degree C.- Maximum time: 3 seconds, one
time, for all terminals.- Do not apply excessive force to the terminals of the switch while
it is heated up by the soldering.- Do not operate the switch whilst it is heated up.Do not put any object on the actuator of the protective film during soldering.When
the switch is mounted on an FPC board, it is necessary to strengthen the FPC board with
a rigidizer on its reverse side to give mechanical support to the switch during operation
and avoid any undulations of the PFC that may bring extra stress to the switch.For
thin switch, do not overstress the product when placed on the PCB.Do not give
too much bending radius to the PCB after soldering, this may damage the body or the
terminals.When handing the product after soldering, please do not overload the
switch in the case the PCBs are stacked or packaged.Be careful not to pollute or
damage switch terminals during handing of PCB (piling up the PCBs).Avoid side
stress and shocks to the actuator during handing. This may result in switch malfunction or
actuator being taken of its working position.Avoid pressing the top sealing film
or actuator with sharp object. Use of ultrasonic wave welding is not recommended. If you
have chosen to use this technology, depending on vibration direction, frequency, and switch
mounting conditions, ultrasonic wave welding may cause resonance phenomenon that can
affect the switch integrity. It can deteriorate the switch performances, and lead to contact
failure such as decrease of contact pressure or abnormal abrasion. Make sure that your
testing confirms that ultrasonic wave welding does not affect the switch. If the product is not
used immediately, please follow handling recommendations: store it as delivered (sealed
bag and desiccant) without direct sunshine or corrosive gas at normal room temperature.
However, it is recommended to use it as soon as possible.
Designing your
system by C&K
Please follow the PCB layout recommended in the product drawing. Do not apply excessive
amount of solder paste or enlarge the soldering pads too much as solder flux may penetrate
inside the switch causing malfunction. Do follow the 'restriction in operation' part on the
product drawing. This is related to actuator shape, maximum angle for actuation and
off centring of actuation axis. These parameters are important to get obtain the best
performance out of the switch specifications. Outside of the recommended values, tactility,
travel, force and life time can be greatly affected up to non functioning. If a hinge motion
must be designed to activate the switch, make sure the actuation point is not sliding or
giving too much side actuation. Do not apply excessive load to the switch. It is always
preferable to have the mechanical stop being integrated in the system actuator/button. The
switch is designed to work under resistive load. For any other usage (inductive or capacitive)
we strongly recommend you to test your configuration beforehand. The circuit shall be
designed to avoid current and voltage surge. Power rating is the maximum value at which
the switch can be continuously used at ambient temperature. Above this value, the switch
can be damaged or cause fire. Bounce time at operation is defined in this specification
and needs to be taken into account for circuit design (multiple information read, delay time,
etc). If a dip solder component needs to be soldered on the back side of the PCB after
processing this switch, precautions must be taken to avoid flux contamination by giving
sufficient distance between the dip solder pads and the switch.
C&K 2 rue Berthollet B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 - www.ckswitches.com