0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FR2025

FR2025

  • 厂商:

    CLARE

  • 封装:

  • 描述:

    FR2025 - Dyad - Clare, Inc.

  • 数据手册
  • 价格&库存
FR2025 数据手册
Dyad® FR2 Features • Small size • SMT-compatible • Easily formed leads • Sputtered ruthenium contacts • Hermetically sealed contacts • Fast switching speed — up to 500Hz • Wide range of available magnetic sensitivities Description Clare’s DYAD® dry reed switches are ideally suited for small switching signal applications. This switch has sputtered ruthenium contacts and an extraordinary seal strength, achieved by a patented laser sealing of the glass. In low level or dry switching environments, both switches typically provide >1 billion operations. The switches have hermetically sealed contacts and offer a wide range of available magnetic sensitivities. Applications • Security • Proximity sensing • Smoke alarms • Automotive • Level sensor • Lamp current sensor • Relays Ordering Information A complete part number is represented by the digits to the right. For example, FR2S1030 is a DYAD® with a minimum operate value of 10 and a maximum of 30. Refer to the switch operating specification charts for available ranges. Special ranges are available upon request. FR2 S XX XX Minimum Operate Value (NI) Maximum Operate Value (NI) Surface Mount Dyad Refer to operating characteristics table for complete part number. Approvals • UL listed DYAD® Part # FR2S1015 FR2S1020 FR2S1030 FR2S1520 FR2S1525 FR2S2025 Operate Range (NI)1 10 to 15 10 to 20 10 to 30 15 to 20 15 to 25 20 to 25 Standard Test Coil The magnetic force (expressed in NI, AT or Ampere Turns) required to cause the reed switch contacts to close is called the pull-in or operate value. FR2 Part # Coil definition Coil resistance Number of turns Wire size (nom. diameter) Bobbin diameter (inside coil) Winding length Coil - 1 NARM1 CTC01 1200Ω 5,000 0.0399mm (AWG 46) 3.96mm 10.4mm DYAD® Surface Mount Part # FR2024 FR2259 FR2282 FR2025 FR2249 FR2026 1 2 3 Operate Range (NI)1,2,3 10 to 15 10 to 20 10 to 30 15 to 20 15 to 25 20 to 25 (1) Consult factory for test procedure. The reed switch shall be placed in the test coil with the gap centered in the core of the coil winding. Test leads and their clips must be non-magnetic. The longitudinal axis of the test coil and the test switch shall be vertical. Tolerance = ± 1.5NI Full Blade Sensitivity Surface Mount Switches are packaged 3,000 parts per reel DS-FR2-R2 www.clare.com 1 Dyad® FR2 Ratings (@ 25˚ C) Parameter Switching Voltage FR2 - DYAD® Switching Current FR2 - DYAD® Carry Current FR2 - DYAD® Switching Frequency FR2 - DYAD® Contact Resistance FR2 - DYAD® (See detailed specifications for more information.) Min Typ Max Units 200 0.5 1.5 500 150 Volts Amps Amps Hz mΩ Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for extended period may degrade the device and effect its reliability. Specifications All parameters are at 25°C unless otherwise stated. PARAMETER Contact Ratings Operate ampere turns range Release ampere turns range Switching Voltage Switching Current Carry Current Contact Rating Life Expectancy CONDITIONS Full Blade Tolerance = ± 1.5NI Full Blade Tolerance = ± 1.5NI Max DC/PeakAC Resistive Max DC/PeakAC Resistive Max DC/PeakAC Resistive Max DC/PeakAC Resistive 1V, 10mA Signal Level 10V, 10mA Low Level 50V, 100mA Telecom Load 100V, 100mA Rated Loads 50mV, 10mA(1) SYMBOL AT AT VL IL IC CR IR TOP TREL TA TO G S MIN 10 5 109 250 -40 -40 TYP 1000 500 2 2 80 Ru 1011 0.3 300 0.13 MAX 30 30 200 500 1.5 10 150 0.5 0.2 +125 +125 +240 20 100 UNITS NI NI VDC mAmps Amps VA x106 Ops x106 Ops x106Ops x106 Ops mΩ Ω pF VDC/Peak AC ms ms °C °C °C Gs Gs grams/unit Static Contact Resistance Contact Material Switch Specifications Insulation Resistance(2) Capacitance Dielectric Strength(5) Operate Time, including bounce Release Time Environmental Ratings Storage Temperature Operating Temperature Soldering Temperature Vibration Resistance Shock Resistance Weight (1) (2) (3) 100V, 25°C, 40% RH Across Open Contacts Between Contacts At nominal coil voltage, 10Hz Square Wave Zener-Diode Suppression(3) 5Hz - 200Hz 11±1ms, 1/2 Sine Wave Contact resistance measured with 4 terminal method, 1.1" between test leads >1012 Ω is available upon request A 24V zener in series with a diode across the coil (4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations (5) 15 ampere turn minimum 2 www.clare.com Rev. 2 Dyad® FR2 Performance Data* DYAD® CM15 Series Operate NI vs. Release NI Test Coil: NARM 1; Full Length Terminals Percent Operate Increase After Lead Cut 30 DYAD® Operate Shift After Lead Trimming 40 35 30 25 20 15 10 5 0 0.7 0.8 0.9 1 1.1 1.2 1.355 DYAD® Dielectric Breakdown vs. Operate Sensitivity 1200 Dielectric Breakdown (VDC) 1000 800 600 400 200 0 8-9 12-13 16-17 20-21 24-2526-32 Min. Avg. Max. 25 Release NI Minimum Maximum 20 15 10 5 0 10 12 14 16 18 20 22 24 26 28 30 Operate NI Overall Length in Inches Average Operate (NI) DYAD® Capacitance Across Open Contacts Average Resistance (mOhms) 40 35 DYAD® Contact Resistance Throughout Life 10V, 12mA Resistive Load Average Resistance (mOhms) 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Operations (Millions) 80 70 60 50 40 30 20 10 0 DYAD® Contact Resistance Throughout Life 50V, 100mA Resistive Load Number of Units 30 25 20 15 10 5 0 0.15 0.2 0.25 0.3 0.35 0.40 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Operations (Millions) Capacitance (pF) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. Mechanical Dimensions DYAD® 2.29 MAX. (0.090) + 7o 0.18 (0.007) DYAD® SMT 2.29 MAX. (0.900) 0.25 MAX. (R 0.010) 4 PLACES 2.03 MAX. (0.080) 15.24 MAX. (0.600) 1.22 (0.048) 1.65 MAX. (0.065) 15.24 MAX. (0.600) 1.20 TYP. (0.047) 1.32 MAX. (0.052) 1.02 (0.040) 17.53 (0.690) + 10o 9.65 REF. (0.380) MAX. TWIST ALLOWED TYP. BOTH ENDS + 5o 34.54 MAX. (1.360) 1.32 MAX. (0.052) 19.56 MAX. (0.770) Recommended Pad Sizes DYAD® SMT 2.54 (0.100) 2.79 (0.110) 16.01 MAX. (0.63) DIMENSIONS mm (inches) Rev. 2 www.clare.com 3 Dyad® FR2 Tape & Reel Packaging Tape and Reel Packaging for DYAD®-Gull Wing Terminals 2.00 .300 ± .013 Top Cover Tape Thickness .10 MAX. (.004) 14.20 (.559) (.012 ± .0005) 1.75 (.069) (.079 ) 1.55 ± .05 (.061 ± .002) 4.00 (.157) 32.00 ± .31 (1.260 ± .012) 23.01 MAX (.906) 20.12 (.792) Embossed Carrier 28.40 (1.118) 2.29 Embossment .50 (.020) Top Cover Tape 8.00 (.315) 2.49 (.098) (.090) 14.63 (.576) 2.00 MIN. DIA. TYP. (.079) 8¡ MAX User Direction of Feed 1.93 .28 (.011 ) 2.49 (.098 ) (.076 ) DIMENSIONS mm (inches) 4 www.clare.com Rev. 2 Worldwide Sales Offices CLARE LOCATIONS Clare Headquarters 78 Cherry Hill Drive Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Clare Switch Division 4315 Earth City Expresssway St. Louis, MO 63045 Tel: 1-314-770-1832 Fax: 1-314-770-1812 Clare Micronix Division 145 Columbia Aliso Viejo, CA 92656-1490 Tel: 1-949-831-4622 Fax: 1-949-831-4628 EUROPE European Headquarters CP Clare nv Bampslaan 17 B-3500 Hasselt (Belgium) Tel: 32-11-300868 Fax: 32-11-300890 France Clare France Sales Lead Rep 99 route de Versailles 91160 Champlan France Tel: 33 1 69 79 93 50 Fax: 33 1 69 79 93 59 Germany Clare Germany Sales ActiveComp Electronic GmbH Mitterstrasse 12 85077 Manching Germany Tel: 49 8459 3214 10 Fax: 49 8459 3214 29 Italy C.L.A.R.E.s.a.s. Via C. Colombo 10/A I-20066 Melzo (Milano) Tel: 39-02-95737160 Fax: 39-02-95738829 Sweden Clare Sales Comptronic AB Box 167 S-16329 Spånga Tel: 46-862-10370 Fax: 46-862-10371 United Kingdom Clare UK Sales Marco Polo House Cook Way Bindon Road Taunton UK-Somerset TA2 6BG Tel: 44-1-823 352541 Fax: 44-1-823 352797 ASIA PACIFIC Asian Headquarters Clare Room N1016, Chia-Hsin, Bldg II, 10F, No. 96, Sec. 2 Chung Shan North Road Taipei, Taiwan R.O.C. Tel: 886-2-2523-6368 Fax: 886-2-2523-6369 SALES OFFICES AMERICAS Americas Headquarters Clare 78 Cherry Hill Drive Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Eastern Region Clare P.O. Box 856 Mahwah, NJ 07430 Tel: 1-201-236-0101 Fax: 1-201-236-8685 Toll Free: 1-800-27-CLARE Central Region Clare Canada Ltd. 3425 Harvester Road, Suite 202 Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 Western Region Clare 1852 West 11th Street, #348 Tracy, CA 95376 Tel: 1-209-832-4367 Fax: 1-209-832-4732 Toll Free: 1-800-27-CLARE Canada Clare Canada Ltd. 3425 Harvester Road, Suite 202 Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 http://www.clare.com Clare cannot assume responsibility for use of any circuitry other then circuitry entirely embodied in this Clare product. No circuit patent licenses nor indemnity are expressed or implied. Clare reserves the right to change the specification and circuitry, without notice at any time. The products described in this document are not intended for use in medical implantation or other direct life support applications where malfunction may result in direct physical harm, injury or death to a person. Specification: PB-FR2-R2 ©Copyright 2000 Ultra-Mini Dyad™, Mini Dyad™, and Dyad® are trademarks of Clare, Inc. All rights reserved. Printed in USA. 3/7/01
FR2025 价格&库存

很抱歉,暂时无法提供与“FR2025”相匹配的价格&库存,您可以联系我们找货

免费人工找货