Document 145
Power Factor Controller Transformers
These parts are designed for use with Motorola MC33261 and MC34261 power factor controllers. They are specifically intended for use in AC-DC pre-converter circuits for electronic ballast and off-line switching power converter applications. N2880-AL and N2881-AL utilize standard materials for lowest cost. Coilcraft can also supply custom transformers optimized for specific combinations of output power and input voltage.
N2880-AL
For output power up to 175 Watts For “universal” 110/220 V input voltage Pins 2-5 960/780 µH Inductance1: DC resistance: Pins 2-5 0.100 max Pins 12-7 0.017 max Isolation: 500 Vrms between windings
1. Tested at 15.75 kHz, 1 Vrms. 2. Operating temperature range –40°C to +85°C. 3. Electrical specifications at 25°C.
1.90 max 48,3
N2881-AL
For output power up to 80 Watts For 110 V input voltage Inductance1: Pins 1-5 350/290 µH DC resistance: Pins 1-5 0.170 max Pins 10-6 0.019 max Isolation: 500 Vrms between windings
1. Tested at 15.75 kHz, 0.2 Vrms. 2. Operating temperature range –40°C to +85°C. 3. Electrical specifications at 25°C.
1.10 max 27,9
6
7
5
6
1.60 max 40,6
1
1.90 max 48,3
12
0.950 max 24,1
1 10
1.10 max 27,9
0.150 ±0.030 3,81 ±0,76 0.200 (1×) 5,08
2 12
0.051 dia (12×) 1,295 1.300 33,02 0.300(9×) 7,62
1
0.150 ±0.030 3,81 ±0,76
10
0.032 dia (10×) 1,12 0.150 (1×) 3,81 0.620 15,75
1
1
12
10
0.200 (7×) 5,08
5
7
6
7
5
6
5
6
13:1 Recommended Board Layout
Weight: 176 g Terminations: Tin-silver over tin over copper Packaging: 36 per tray
12.4:1 0.063 dia (12×) 1,60
Weight: 22.2 g Terminations: Tin-silver over tin over copper Packaging: 30 per tray
0.044 dia (10×) Recommended 1,12 Board Layout
Specifications subject to change without notice. Please check our website for latest information.
Document 145
Revised 01/06/09
© Coilcraft, Inc. 2009
很抱歉,暂时无法提供与“N2881-AL”相匹配的价格&库存,您可以联系我们找货