n14
Width across flats 13
Inner view ( 2 : 1 )
Technical specification:
3pos
60 V
Current rating:
IEC 61076-2-104
3 A at 40°C
with 0,25mm²
Insulation resistance:
IEC 60512
>= 100 M
Pollution degree:
IEC 60664-1
3/2
Width across flats 12
Degree of protection:
IEC 60529
IP 67, in mated
condition
Max. external cable
diameter see table
Temperature range:
IEC 60664-1
-30°C ... +85°C
Mating cycles:
IEC 60512-9a
>= 100
4pos
30 V
Ω
(REF. 40)
Rated voltage:
IEC 61076-2-104
n13,7
4
3
min. n1
4
1
2
Materials:
1
3
4 pos
3 pos
Contact:
CuZn
Contact plating:
Au over Ni
in mating area
Contact carrier:
PA6 GF, UL 94
Cable sealing:
NBR
O-Ring:
Silicone
Coupling nut:
Die cast, nickel plated
Housing:
PA6 GF, UL 94
Directive 2002/95/EC RoHS compliant
DO NOT ALTER CAD DRAWING BY HAND
Installation specification:
Index: c 10.08.11 K.H. Ä4071
Rated volltage and Current rating updated
date
tolerance of cable:
general tolerance:
0
0,0
0,00
± 0,50mm
± 0,25mm
± 0,10mm
THIS DRAWING MAY NOT BE COPIED OR REPRODUCED IN ANY WAY, AND
MAY NOT BE PASSED ON TO A THIRD PARTY WITHOUT WRITTEN PERMISSION.
OWNERSHIP AND COPYRIGHT OF CONEC GmbH
name
drawn 16.12.10
Petker
appd.
Kühle
16.12.10
0,4 Nm
Conec
installation tool:
Torque wrench:
36-000200
Insert across flats 13:
36-000220
Pos:
Cable-n:
SAL - 8 - RKC3 - L
3
4 - 5,5mm
SAL - 8 - RKC4 - L
4
4 - 5,5mm
Part no:
Description:
42-00006
42-00008
title:
dim. in mm
Recommended
torque:
Female connector M8x1,
solder cup, axial,
solder connection
dwg no:
42K1A284
R
part no:
see table
很抱歉,暂时无法提供与“42-00008”相匹配的价格&库存,您可以联系我们找货