H
G
F
E
D
C
B
A
46,1 max.
20,9 max.
1,5
PCB hole pattern
edge of daugther card for reference only
F
F
18,65
n1
,7
+0 - 0 ,1
24,5 `0,05
(2x )
22x suggested hole size
13,4 `0,05
n2,65
+ 0,1 -0
6 `0,05 2 `0,05
(2x)
41,3 max.
6,6 `0,05
3,9 `0,05
2,2 `0,05
12,47 `0,05
E
Marking on opposite side (see note 6)
12,47 `0,05
14,72
4,5 `0,05
A
4,5 `0,05
24,08
E
33 b 13 b
6,6 `0,05
3,9 `0,05
2,2 `0,05
B
3 `0,05 9,4 `0,05 13,7 `0,05 10 `0,05 12 `0,05 14,5 `0,05
Drilled hole n1,75 `0,025
D
17,5 max.
28,6 max.
Contact 27 datum plane
4,95
8x suggested hole size
18,5 `0,05 12 11 21,2 `0,05 22,55 `0,05 1
Drilled hole n1,15 `0,025
4
D
5
10
(22x)
23,9 `0,05
Contact 27 datum plane
(8x)
9
Copper thickness minimum 25µm
Copper thickness minimum 25µm
2
7
Tin thickness minimum 15µm
Tin thickness minimum 15µm
C
Finished hole + 0,09 n1 - 0,06 (22x)
Finished hole + 0,09 n1,6 - 0,06
(8x)
C
NOTES:
1. MATERIALS AND FINISHES:
3
8
6
13
A ( 10 : 1 )
B ( 10 : 1 )
- INSULATOR: GLASS FILLED PLASTIC UL 94 V-0 RATED, GREY RAL 7035 - CONTACTS: COPPER ALLOY, PLATING MATING AREA: 0,8 µM GOLD OVER NICKEL PLATING TERMINATION AREA: 0,8-1,5 µM TIN (SN 100) 2. ELECTRICAL CHARACTERISTICS: CREEPING AND CLEARANCE DISTANCE; MINIMUM SPACING: - CONTACTS 5-16 TO ANY OTHER CONTACT WITHIN THIS GROUP: 0,7 MM - CONTACTS 17-24 TO ANY OTHER CONTACT WITHIN THIS GROUP: 2,5 MM
B
- CONTACT 25 TO 26: 5,5 MM - CONTACTS 27-34 TO ANY OTHER CONTACT WITHIN THIS GROUP: 1,4 MM - CONTACTS 13-16 TO 17-20: 3,0 MM - CONTACTS 21-24 TO 25-26: 4,0 MM - CONTACTS 25-26 TO 27-29: 2,0 MM CONTACT CURRENT RATING: - POWER CONTACTS: 16 AMPERES MINIMUM, TESTED PER CSA C22.2 NO. 182.3-M1987, ALL CONTACTS UNDER LOAD - SIGNAL CONTACTS: 2 AMPERES NOMINAL INITIAL CONTACT RESISTANCE PER IEC 512-2, TEST 2b: - POWER CONTACTS: 0,0022 OHM MAX. - SIGNAL CONTACTS: 0,0085 OHM MAX. INSULATION RESISTANCE: 5 G OHM PER IEC 512-2, TEST 3a, METHOD A
1 5 3 2 2 2 3 5 3 1 3 1 1 quantity
Fixing plate Signal contact type 7 Signal contact type 6 Signal contact type 5 Signal contact type 4 Signal contact type 3 Signal contact type 2 Signal contact type 1 Power contact type 4 Power contact type 3 Power contact type 2 Power contact type 1 Case 34pos. male part description partlist
DO NOT ALTER CAD DRAWING BY HAND
13 12 11 10 9 8 7 6 5 4 3 2 1 item
tolerance
B
dwg no. / norm
material
2,5:1 (10:1) see notes
THIS DRAWING MAY NOT BE COPIED OR REPRODUCED IN ANY WAY, AND MAY NOT BE PASSED ON TO A THIRD PARTY WITHOUT WRITTEN PERMISSION. OWNERSHIP AND COPYRIGHT OF CONEC GmbH
finish: see notes
ISO 2768-m
date
drawn 22.08.05 appd. norm d-old
dim. in mm
name
scale: material: title:
Mankopf Kühle
MALE CONNECTOR 30pos.
PRESS-FIT ANGLED AdvancedTCA
A
22.08.05
A
3. POSITIONS WITHOUT CONTACTS: 1, 2, 3, 4 4. WORKING TEMPERATURE: -55°C TO +125°C 5. PRESS-FIT PART OF CONTACTS ARE PATENT PROTECTED 6. CONNECTOR IS PART MARKED: PART-NO. CONEC ABC
H G F E D
dwg no:
R
Inventor
2xb
Ä 2592
23.10.06
HS
46K2A005
part no:
A
DINA2 sh: 1
rev. description
date
name
B
ATC30W08MAE1S5X
C