CCPB-3-50CF

CCPB-3-50CF

  • 厂商:

    COOPER(科普斯)

  • 封装:

  • 描述:

    CCPB-3-50CF - Compact Circuit Protector Base - Cooper Bussmann, Inc.

  • 详情介绍
  • 数据手册
  • 价格&库存
CCPB-3-50CF 数据手册
CUBEFuse® Compact Circuit Protector Base (CCPB) For Quik–Spec™ Coordination Panelboards Specifications: • CCPB Ampacity rejection breaks: 15A, 20A, 30A, 40A, 50A and 60A • 1-, 2- and 3-Pole versions • For systems 600Vac (or less) • Box lug loadside terminal: • 18-6AWG single & dual rated, solid or stranded – 75°C, Cu only • 4AWG single – 75°C, Cu only • Box lug loadside terminal torque: 18-10AWG 20 Lb-In (2.2 N•m), 8-4AWG 35 Lb-In (3.9 N•m) The revolutionary Cooper Bussmann® CCPB with CUBEFuse® is designed as a fused branch circuit disconnect with fuse holder for the Cooper Bussmann® Quik-Spec™ Coordination Panelboard. The CCPB with CUBEFuse simplifies selective coordination and allows for isolation of individual branch circuit loads for safe work practices. • Spade terminal load connection: Max. 30A suitable for use with #8-32UNC screw • Bolt-on style bus connector, #10-32-UNC Hex flange Phillips screw, torque to 25 Lb-In (2.8N•m) • Lockout/tagout: 4mm shank lock or standard pin-out devices (Brady pin-out wide device P/N 90850 or Ideal P/N 44-784 • Bolt-mounted design into Quik-Spec Coordination Panelboard bus • Local indication: illumination requires closed circuit and minimum 90Vac operating voltage • RoHS compliant Agency Information: UL 98 Listed, File E302370, Guide WHTY cULus to CSA Standard 22.2 No. 4, File E302370, Guide WHTY7 CE Compliant Shipping Weight: 2.03 lbs per carton Carton quantity: 6 poles Environmental Data Storage and operating temperature: -20ºC to 75ºC* *For fuse performance under or above 25ºC, consult fuse performance derating charts. Product Features and Benefits • Uses IP20 finger-safe with current-limiting, time-delay Class J performance • High Short-Circuit Current Ratings at 200kA • Disconnect rated to provide means for load isolation • Full voltage rated at 600Vac • UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection • 1-, 2- and 3-pole versions are horsepower rated • Patented rejection feature helps prevent overfusing • Complies with UL and cULus • Open fuse indication light per pole • Additional open fuse indication can be provided by using the indicating CUBEFuse version • Built-in switch/fuse interlock prohibits removing the fuse while energized • Permanent lockout/tagout provisions • Lock-On provision Low-Peak® CUBEFuse® 1008 BU-SB08561 Form No.CCPB Page 1 of 3 Data Sheet 1161 Bolt-on style bus connector Symbols for ON and OFF Lockout/tagout provision Local, neon open fuse indication light Disconnect handle CUBEFuse base Box lug loadside terminal Spade terminal connection Technical Ratings CUBEFuse Type (Class J performance) CCPB Part Numbers CCPB-1-15CF CCPB-2-15CF CCPB-3-15CF CCPB-1-20CF CCPB-2-20CF CCPB-3-20CF CCPB-1-30CF CCPB-2-30CF CCPB-3-30CF CCPB-1-40CF CCPB-2-40CF CCPB-3-40CF CCPB-1-50CF CCPB-2-50CF CCPB-3-50CF CCPB-1-60CF CCPB-2-60CF CCPB-3-60CF Poles 1 2 1-15 3 1 2 171⁄2-20 3 1 2 25-30 3 1 2 35-40 3 1 2 45-50 3 1 2 60 3 600Vac TCF60RN TCF60 60A 200kA 600Vac TCF45RN, TCF50RN TCF45, TCF50 50A 200kA 600Vac TCF35RN, TCF40RN TCF35, TCF40 40A 200kA 600Vac TCF25RN, TCF30RN TCF25, TCF30 30A 200kA 600Vac TCF17-1/2RN, TCF20RN TCF17-1/2, TCF20 20A 200kA 600Vac Fuse Amp Range Voltage Rating Non-Indicating Indicating* Max. Fuse Ampacity SCCR Hp Ratings 0.5Hp@120V 1.5Hp@240V 3Hp@240V 5Hp@480V 7.5Hp@600V 0.75Hp@120V 2Hp@240V 3Hp@240V 7.5Hp@480V 10Hp@600V 1.5Hp@120V 3Hp@240V 5Hp@240V 15Hp@480V 10Hp@600V 2.0Hp@120V 3Hp@240V 7.5Hp@240V 20Hp@480V 10Hp@600V 3.0Hp@120V 5Hp@240V 7.5Hp@240V 20Hp@480V 10Hp@600V 3.0Hp@120V 7.5Hp@240V 7.5Hp@240V 20Hp@480V 10Hp@600V TCF1RN, TCF3RN, TCF6RN, TCF10RN, TCF15RN TCF3, TCF6, TCF10, TCF15 15A 200kA *1A indicating CUBEFuse not available. Correct fit with CCPB disconnect requires indicating CUBEFuse with date code R38 or later. 1008 BU-SB08561 Form No.CCPB Page 2 of 3 Data Sheet 1161 CUBEFuse® Motor Sizing Table Motor Size (Hp) 0.167 0.25 0.333 0.5 0.75 1 1.5 2 3 ** 0.167 0.25 0.333 0.5 0.75 1 1.5 2 3 5 7.5** 0.5 0.75 1 1.5 2 3 5 7.5** 0.5 0.75 1 1.5 2 3 5 7.5 ** Motor* FLA (Amps) 4.4 5.8 7.2 9.8 13.8 16 20 24 34 2.2 2.9 3.6 4.9 6.9 8 10 12 17 28 40 2.5 3.7 4.8 6.9 7.8 11 17.5 25.3 2.4 3.5 4.6 6.6 7.5 10.6 16.7 24.2 Low-Peak® CUBEFuse® (Amp Rating) Optimal Code Heavy Protection Max Start 10 10 10 10 15 15 15 15 15 15 20 20 25 25 30 25 30 35 30 35 45 40 45 50 50 60 N/A 6 6 6 6 6 6 6 10 10 10 10 10 15 15 15 15 15 17.5 15 20 20 20 25 25 25 30 35 45 50 60 60 N/A N/A 6 6 6 6 10 10 10 10 10 15 15 15 15 15 17.5 17.5 20 20 30 35 35 40 45 50 6 6 6 6 10 10 10 10 10 10 15 15 15 15 15 17.5 20 20 25 30 35 40 45 50 Motor Size (Hp) 0.5 0.75 1 1.5 2 3 5 7.5** 0.5 0.75 1 1.5 2 3 5 7.5 10 15 20** 0.5 0.75 1 1.5 2 3 5 7.5 10 ** Motor1 FLA (Amps) 2.2 3.2 4.2 6 6.8 9.6 15.2 22 1.1 1.6 2.1 3 3.4 4.8 7.6 11 14 21 27 0.9 1.3 1.7 2.4 2.7 3.9 6.1 9 11 Low-Peak® CUBEFuse® (Amp Rating) Optimal Code Heavy Protection Max Start 6 6 6 6 6 6 10 10 10 10 15 15 15 15 15 15 20 20 25 30 30 35 40 45 3 3 3 3 3 3 6 6 6 6 6 6 6 6 6 10 10 10 15 15 15 17.5 20 20 25 25 30 35 40 45 40 50 60 3 3 3 3 3 3 3 3 3 6 6 6 6 6 6 6 10 10 10 15 15 15 20 20 17.5 20 20 Voltage Voltage 115Vac, 1-Phase 230Vac, 3-Phase 230Vac, 1-Phase 460Vac, 3-Phase 200Vac, 3-Phase 575Vac, 3-Phase 208Vac, 3-Phase Note: Use Code Max column for low to moderate reverse/jog/plug applications. Heavy Start permitted only if Code Max does not allow motor start-up. *Based on motor FLA from NEC® tables 430.248 and 430.250. **Max. Hp rating for the CCPB 60 Amp device at specified voltage. Dimensional Data — in (mm) 1.0 (25.4) 3.9 (99.4) 2.0 (50.7) 3.0 (75.8) 2.7 (69.1) 2.9 (73.5) Ø.2 (5.8) Ø.5 (12.9) 39 For details on the CCPB and its use in the Quik-Spec™ Coordination Panelboard, see data sheet 1160. The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. © 2008 Cooper Bussmann St. Louis, MO 63178 636-394-2877 w w w. c o o p e r b u s s m a n n . c o m 1008 BU-SB08561 Form No.CCPB Page 3 of 3 Data Sheet 1161
CCPB-3-50CF
1. 物料型号: - CCPB-1-15CF、CCPB-2-15CF、CCPB-3-15CF等,这些型号表示不同的极数(1极、2极、3极)和不同的熔断器额定电流范围(15A)。

2. 器件简介: - 该器件是Cooper Bussmann®品牌的CUBEFuse® Compact Circuit Protector Base (CCPB),设计为带有熔断器座的熔断分支电路断开装置,用于Cooper Bussmann® Quik-Spec™ Coordination Panelboard。

3. 引脚分配: - 提供了1极、2极和3极版本,适用于600Vac或更低的系统。

4. 参数特性: - 包括15A、20A、30A、40A、50A和60A的CCPB Ampacity rejection breaks,以及不同极数和电压等级的产品规格。

5. 功能详解: - 使用IP20指端安全的Low-Peak® CUBEFuse®,具有限流、延时的Class J性能。 - 高短路电流额定值达到200kA。 - 断开装置额定值提供负载隔离手段。 - 600Vac全电压额定。 - UL 98 Listed,适用于分支电路断开和分支电路保护。 - 专利拒绝功能有助于防止过载。

6. 应用信息: - 适用于需要选择性协调和隔离单个分支电路负载的安全工作实践。

7. 封装信息: - 包括盒式接线端子、叉形端子负载连接和螺栓式母线连接器等封装细节。
CCPB-3-50CF 价格&库存

很抱歉,暂时无法提供与“CCPB-3-50CF”相匹配的价格&库存,您可以联系我们找货

免费人工找货