CPI 2.25 and 2.50 kW S uperLinear tm T WT Amplifiers for Satellite Communications
X- Band
The TL22XI and TL25XI TWTAs Up to 2.5 kW (1110 W operating) TWT Compact High Power Amplifiers, featuring high efficiency, small size and integral computer interface.
X-Band
Compact
Global Applications 2 . 2 5 a n d 2 . 5 0 k W S u p e r L i n e a r tm C o m p a c t T W TA s
Provides 2250 or 2500 watts of equivalent linear power (1000 or 1110 watts operating) in a compact nine rack-unit package, digital ready, for wideband, single- and multi-carrier satellite service in the 7.9 – 8.4 GHz frequency band. Designed to operate at up to 1260 watts flange linear power for multi-carrier uplinks. Ideal for transportable and fixed earth station applications where space and prime power are at a premium. 30% smaller than traditional HPAs.
E fficient and Reliable
Meets International Safety Standard EN-60215 and EMC Standard EEC 89/336 to satisfy worldwide requirements.
Easy to Maintain
Modular design and built-in fault diagnostic capability with convenient and clearly visible indicators for easy maintainability in the field.
Worldwide Support
Employs an ultra-high efficiency dual-depressed collector helix traveling wave tube backed by many years of field-proven experience in airborne and military applications. The collector design is optimized for super-cool operation.
Simple to Operate
Backed by over two decades of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes sixteen regional factory service centers.
User-friendly microprocessor-controlled logic with integrated computer interface, digital metering, pin diode attenuation, optional integrated linearizer for improved intermodulation performance, and BUC option for use with L-band modems.
811 Hansen Way P.O. Box 51625, Palo Alto, CA 94303 tel: + 1 (650) 846-3803 fax: + 1 (650) 424-1744 e-mail: m arketing@satcom.cpii.com www.cpii.com/satcom
X -B a n d
SPECIFICATIONS, TL22XI and TL25XI
Electrical
Frequency Output Power TWT - TL22XI TWT - TL25XI Flange - TL22XI Flange - TL25XI Linear Power TL22XI TL25XI Bandwidth Gain RF Level Adjust Output Power Adjustability Gain Stability Small Signal Gain Slope Small Signal Gain Variation 7.9 - 8.4 GHz 2250 W min. (63.54 dBm) 2500 W min. (63.98 dBm) 1000 W max. operating (60.00 dBm) 1110 W max. operating (60.45 dBm) 1000 W with linearizer option 1110 W with linearizer option3 500 MHz 75 dB min. at rated power output 78 dB min. at small signal 0 to 30 dB continuous ±0.1 dB ±0.25 dB/24 hr max. (at constant drive and temp.) 0.02 dB/MHz max. 0.5 dB pk-pk max. over any 40 MHz; 3.0 dB pk-pk max. across the 500 MHz band; 4.0 dB pk-pk w/linearizer; 5.0 dB pk-pk w/ BUC; 6.0 dB pk-pk w/linearizer and BUC 1.25:1 max. 2.0:1 max. for full spec compliance; any value without damage -50 dBc below 10 kHz, -20 (1.5 +log F kHz) dBc, 10 kHz to 500 kHz (F in kHz) -85 dBc above 500 kHz Shock and Vibration
Electrical (continued)
Group Delay (in any 40 MHz band) Primary Power2 0.02 ns/MHz linear 0.002 ns/MHz2 parabolic 0.5 ns pk-pk ripple max. All ratings are ±10%, 47-63 Hz, 5-wire, 3-phase with neutral and ground 208 VAC (with or w/o neutral) 380 to 415 VAC 0.95 min. 5.5 kW max.; 4.9 kW typ. @ 1000 W linear RF output power; 4.2 kW typ. @ 800 W; 3.9 kW typ. @ 600 W; 3.6 kW typ. @ 400 W; 3.3 kW typ. @ 200 W; 2.8 kW typ. @ 100 W (Power consumption 10% less for 2.25 kW HPA, typ.)
OPTIONS & C O M PA N I O N PRODUCTS: • Integral Linearizer • Remote Control Panel • Redundant and Power Combined Subsystems • External Receive Band Reject Filter • Integral L-Band Block Upconverter (BUC)
Power Factor Power Consumption
Environmental
Ambient Temperature Relative Humidity Altitude -10° to +50°C operating -40° to +71°C non-operating 95% non-condensing Up to 10,000 ft (3000 m) with standard adiabatic derating of 2°/1000 ft.; 50,000 feet non-operating Designed for normal transportation environment per Section 514.4 MIL-STD-810E. Designed to withstand 20g at 11 ms (1/2 sine pulse) in non-operating condition
Input/Output VSWR Load VSWR Residual AM, max.1
Phase Noise1 IESS-308/309 phase noise continuous AC fundamentals related Sum of spurs AM/PM Conversion Harmonic Output Noise and Spurious
Mechanical
10 dB below mask at -10 dB backof -50 dBc -47 dBc 6°/dB max. With optional linearizer, can be tuned to 2°/dB max. -80 dBc -130 dBW/4 kHz from 3.4 to 4.2 GHz -65 dBW/4 kHz from 4.2 to 12.0 GHz -110 dBW/4 kHz from 12.0 to 40.0 GHz -23.5 dBc max, 7.9 - 8.4 GHz (-25 dBc max. at 4 dB backoff with linearizer); Cooling(TWT) Forced air with integral blower and power supply fan. Maximum external pressure loss allowable: 0.25 inch water gauge. Type N female CPR 112 F waveguide flange, grooved, threaded UNF 2B 10-32 Type N female 19 x 15.75 x 24 in. (483 x 400 x 610 mm) 155 lbs. (70.5 kg) max.
RF Input Connection RF Output Connection RF Power Monitors Dimensions (W x H x D) Weight
Intermodulation with two equal carriers, total output power level at 56 dBm
1Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / % imbalance. 2AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics must be considered when choosing UPS sources. 3Up to 1250 watts linear power available through optimization of linearizer settings.
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 189, ISSUE 5 02/08 PDF
很抱歉,暂时无法提供与“TL25XITWTAS”相匹配的价格&库存,您可以联系我们找货