750 W, CW High Efficiency Helix TWT Series, 13.75 GHz to 14.50 GHz, Coaxial Input, Waveguide Output, and Air Cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, & dual stage depressed collector. Model Number VTU-6397D5A VTU-6397C3A VTU-6397D7 VTU-6397D5 VTU-6397C3 VTU-6396D5 VTU-6396D3 Frequency (GHz) 12.75 – 14.5 13.75 – 14.5 12.75 – 14.8 12.75 – 14.5 13.75 – 14.5 12.75 – 14.5 13.75 – 14.5 Power Output (Min.) 750 W 750 W 700 W 700 W 700 W 600 W 600 W
Operating Parameters Features
• • • • • •
750 Watts 13.75 GHz – 14.50 GHz Coaxial Input Waveguide Output Weight: 25 lbs. max Air Cooled Units: Maximum: Minimum: Nominal: Typical (700 W): Typical (750 W): Collector Voltage 2 Units: Maximum: Minimum: Nominal: Typical (700 W): Typical (750 W): % 27.0 25.0 26.0 Collector Current 2 mA 420.0 Cathode WarmUp Time minutes Drive Power Prime Power Watts 1950 Goal 1925 Thermal Dissipation Load VSWR VSWR 1.2 Filament Voltage Vdc 6.4 6.2 6.3 Filament Current A 1.8 1.0 1.5 Helix Voltage kV 12.5 11.8 12.4 Helix Current mA 10.0 Collector Voltage 1 % 53.0 51.0 51.0 Collector Current 1 mA 30 dc 240 rf 17 dc 215 rf
3.0
dBm
18
Watts
1900
3.0 400 dc 200 rf 10 1350
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For additional information on CPI MPP products contact: CPI MPP, Helix TWT Operation - 811 Hansen Way, Palo Alto, CA 94303-0750 Phone: 650-846-3900, Fax: 650-494-8779, Email: marketing@mpp.cpii.com, www.cpii.com/mpp
很抱歉,暂时无法提供与“VTU-6396D3”相匹配的价格&库存,您可以联系我们找货
免费人工找货